Permit HVAC 1085 Atlantic Blvd 89 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001413 Date 10/02/12 Property Address . . . . . . 1085 ATLANTIC BLVD 89 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/31/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: A -5( Vd , PROJECTVALUE $ 7,117- 72, , 11 ARI# 14 7 000 2_77 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit -Z Vz_ Heat: Unit Quantity BTU's Per Unit 5 KLJ Seer Ratin2 15 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The pen-nit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company ALLA KvO-(-S f-Cgn"164-11 ((Aq��AAcle Phonc%5-5&-- ax' 4. -77?. Co. Address: _4ZZA, 0.,i'PLkLj _-j city &Lx.&,J - State EL ziP3�&,Crn License Holder(Print): 7;&rr j.,t CA-RLLnft So State C ication/Registration#C410 41/60 Notarized Signature ofLicense Ho/de�:�� SHIRLI'W t C 7- 4 r. ser Zo m is 4day 2o 2— MY com "'S ibed befo m Woo �f EXPMES: qbruary 14,2014 ic Porided'bro otary Pu ic C E RT I F I E D www.ahridirectory.org Ceftificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(3),or the unauthorized afteration of date listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products ofAHRI.This Certificate shall only be used for Individual,personal and confidential reference purposes. The contents ofthis Certificate may not,In whole or In part be reproduced;copied;disseminated;entered Into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's Individual,personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on this certificate can be verified at www.shridin)ctory.org, Air-Condifloning,Heating, click "Verify Ce rtificate"link and enter the AHRI Certified Reference Number and the date on vih rtifinate was Issued,which Is listed above,and the Certificate No.,which Is listed below. NO ILI and Refrigeration Institute 02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 DesignStar Load Calculation Results are intended fbr usewith Rheem heating and cooling systems only The Now Dogroo of Oofrtorltm 'Customer Information 77-7 oca ion-, Street Address 1080*Atlantic blvd, DUVAL, FL 32233, .......... ........... ........... .............. ............ Latitude, Longitude 30.33750, -81.16860 ........................... ........... House Square Footage: 1050 sq. ft. Name:, Terry Runnels ....................... ...... ............ ................... Phone. 863-581-4268 ............. .......................................................... .......... .......... Email: tertinsr@aol.com ..................................................... ................................................................-.................-................................ ............ House Information SHR 35 ............- ............... ...................... .......................... ............. ..........................................- Number of residents 4 ................ ......... ............ ..................- ............ ............................ ................ Ceiling height 8 -1-11-1-1---------...............------ ..........-........................ ......................... ................. Wall U-value I R-value 0.091 11 .......... .......... .. ........... ............ Floor U-value R-value 0.2 15 ................................. 7-------------7............................... Ceiling U-Value R-value 0.05 119 ..................... ......................................... ............... .......................... ........................ ....................... Window U-value 1 .............. .......... ............................ Window SHGF '0.85 .............................. ................... ....................... ........... ................................... ............... Moisture grains 0.85 .................. ........................... ......................... .............. .................... Duct loss % ..........- ............. ................. ............ ....................... ............. .................. Duct gain % 10 .................... ..................................... ........ ......... Cooling infiltraction (ACH) 0.6 ...........-........... ............................ ,_.......... .......... Heating infiltration (ACH) 0.8 ----------- Winterventi ation ........... .......... ............ ........ ............. .................. ........... Summer ventilation 0 Design Conditions ..............0-utd,o.or................... .......... .................. Cooling .......................... Dry bulb (OF) 32 93 .............. .............. .......... ........... Daily range M .......... ....... Relative humidity 50% ................................................................. Moisture difference 53 .......... .......... ................................... ........... ........... ............... .......... ................ Indoor Heating Cooling ...................... ....................... ........... ...................-........................- ....................--........................ ...... .......... Indoor.temperature (OF) 70 75 ............. .......... ................. ........... .............. Design temperature difference(OF) 38 18 ................... ................... ....................................1-1.....,............. ........... ................. ..........- �,Heatinq Loads Area Btuh % of load ........... ...................................................... Wall 2201 8.8 ................... ............... -------- ................. Floor 7980 31.9 ........... .................... ........................................ .................. Ceiling 2115 8.5 ............ .........-................ ..................... ............ Windows 6080 24.3 ............ ------ Infiltration 4354 17.4 ....................... ...... ................................... System Efficiency Loss 2273 9.1 ......................---.......... ............... Tota 1: 25002 .......... .............. .................................. ............................................ Heaflng Loads 25,002 BTU/hr Ceiling Wall Floor A ON System Efficienc Infiltration Windows -7- ------I--- e efin 00 S II h-:'--% ipf oa 3tu Wall 1042 4 ............... el-1119,�" ',-7 ........... Windows 15150 58.6 '777 7�' -7 77-7'7� 6-6 15 ens c........... Latent Infiltration, 2815 10.9 -4 Internal 1178 4.6 Latent People Load 483 1.9 7 77 .................7�......... ................... ota .......... Sensible load ......................... ........ ............. ........... .......... Latent load 3298 .......... .............. .................. .................. SHR 0.87 ............ ............. ...... Capacity at .75 SHR 2.51 Tons ..........- ........ .......................... Cooling Loads 25,856 BTU/fir Sensible People Load Latent People Load Ceiling Wall Internal Sensible Infiltratior System Efficlenc! Windows Latent Infiltration AED Graph 30000 20000 V 10000 0 8arn 9am 10am 11am 12PM 1PM 2pm 3pm 4prn 5prn 6prn 7prn 8prn I= Hourly Loads---Ave-rage--] ,ACCA Manual S System equipment selection will be made using the following Manual S derived values. Summer Outdoor 93"F ........... ............... Summer Wet Bulb 77"F .......... ....... Summer Indoor 750F ............. ............... .......... ........... ................................ .......... Summer.Design Grains 50% ............-.............- .............-...................................... ................. ..................................................... ............... ...............--................... Winter Outdoor 320F .......... .................................... .......... ...... ........... .................................... Winter Indoor 70OF ................ ................ ...................................... ........................... ............ .............. Sensible Cooling 22,558 Btuh ........... ........ ........................ ........................-. ..........-.- ...................... ............ Latent Cooling 3,298 Btuh ............... ........... ............ ..........-................... ............ Required Cooling Airflow 1,025 CFM ....................................... ................ .............................. ............................ ..................................... Sensible Heating 2 5,002 Btu h ............ ................... .......... .............. ----------- Required Heaing Airflow 325 CFM ........... .......... All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements,All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree