Permit HVAC 1085 Atlantic Blvd 87 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001415 Date 10/02/12
Property Address . . . . . . 1085 ATLANTIC BLVD 87
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
1085 ATLANTIC LLC RUNNELS AIR CONDITIONING
5118 N 56TH ST 4222 CINDY RD
TAMPA FL 33610 LAKELAND FL 33810
(863) 581-4268
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . valuation . . . . 0
Expiration Date . - 3/31/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DEPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: A #
PROJECT VALUE �R. 75,1 2 7 ARI 2_-7
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit. Seer Rating_
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit .21
Heat: Unit Quantity I BTU's Per Unit Seer Rating— . 1
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify thamt7have A7read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name A M Phone Number
Mechanical CompanyALLA Ke-(S k,-0,x,,4,0�14 '(Aa��Pice Phon&05- a x —7?
Co. Address: city La-LaL&nd StateF --Eg tn
—L Zip,
License Holder(Print): 7—�rr Li E,-RLLnr1e1-S St!ate:�Iification/Registration#dheb 461160
Notariz d S�gqature
1�e i aguse
% SHIRLEY L.GRAHMA
A
COMMISSION#DD 957760S Mand -4?SC' -bed befo:!Z4 of 20g,
re
MY �j
�d2oj
qf�-S:February 14,2014
EXPI
rwr",
Bunded Tnto Notary PublIC Underwrl ,
a ure of Notary Public
CERTIFIEDT11
L www.aliridirectory.org
Certificate of Product Ratings
AHRI Certified Reference Number: 4700027 Date: 9/10/2012
Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit
Outdoor Unit Model Number: GSX1 30301 D*
Indoor Unit Model Number: AR*F303016C*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 28400
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(3)listed on this Certificate.AHRI expressly disclaims all Ilablifty for damages of any kind arising out of the use or performance of the product(*),orthe
n of data listed on this Certificate.Cartified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,In whole or In part,be reproduced;copied;disseminated;entered Into a computer database;or otherwise utilized,In any
form or manner or by any means,except for the user's Individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectDry.org, Air-Condifloning,Heating,
clickon"Verify Certificate"link and entertheAHRI Certified Reference Number and the date on
which the certificate was Issued,which Is listed above,and the Certificate No.,which Is listed below. on ILI and Refrigeration Institute
02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917767496898595
.49011hil
DesignStar Load Calculation
Results are intended for use with Rheem heating and cooling systems only
'No Now Oogioe of Oomfonlu
customer Information
7-� 777 ��'77777 7 777
L
...........
...............
Street Address 106f Atlantic blvd, DUVAL, FL 32233
.............
Latitude, Longitude 30.33750, -81.7686"'
.......... ...... ------- ...... .............. ..............
...........
House Square Footage: 1050 sq. ft.
............. ....................
.......... ....... ................
Name:, Terry Runnels
.......... .......... ................................ ------- ...........
Phone: 863-581-4268
............. ........ ..................... ............ .......----------
Email: terunsr@aol.coni
........... ........... ............ .................... .............
iHouse Information
SHR .75
................ .............. .....................
Number of residents
4
-----------
...........- ........... ..............
Ceiling height 8
------------I .......... ............. ............
Wall U-value R-value 0.09111
........... ....................................................... .......................
Floor U-value R-value 0.2 5
.......................... ...............-............... ........................... ...................... .......................
Ceiling U-value I R-value 0.05 19
....................... ...........- .......... ................... ...........
..................
Window U-value
.......... .......................................... ............. ......... ------...........
Window SHGF
0.85
..........-.........................
'"*"............ ... ....... ............. .................*.................. .....................................
Moisture grains 0.85
.................... ....................... ...................... .......... ...........
Ductloss %
........... .................. ................. .............. ...............................................I
Duct gain % 10
....................---......... -------- ........ ......
Cooling, ihfiltraction WH) 0.6
.....................
--........... .................... ........................ ..............
Heating infiltration (ACH) 0.8
-7------------ ......... ------ ---------
Wi oterven:6 I ati,on
............... .........................
............ .......... .......... ..........
Summer ventilation 0
I'Deskin Conditions
Outdoor Heating Cooling
.............-.--....... ----------- ............. ......
Dry bulb (OF) 32 93
............ ............ ................. ................... ...............................
............ ...........................................
Daily range M
........... ------- ............. ............
Relative humidity
50%
.................. ................... ................................................ .................... .............. .......... ..........
Moisture difference 53
.................--.............. ................... ................................................... ......................................................................................
Indoor Heating Cooling
.............---1.1--........ ..................... ...................................... .......................
Indoor temperature (OF) 70 75
...................... .............. ..................... ...................... ........... .....................................-1-1-1--.............
Design temperature difference(OF) 38 18
.......... .....................I 1 11-.......................... ................... ....................... .................... ..................................... .............................................
Heat[nq: Loads
Area Btuh % of load
.......................
Wall 2201 8.8
........... ............... ........................
Floor 7980 31.9
.............. ............ ..........
Ceiling 2115 8.5
.................. .....................
Windows 6080 24.3
.......... ........................... ...................1.1-11-........
Infiltration 4354 17.4
..........................
Systern Efficiency Loss 2273 9A
............... ............ ............- .............
Tota 1: 25002
............
Heating Loads
25,002 BTU/hr
Ceiling
Wall
Floor 6'M
"�V'QTM'%'
'j,
NO
System EfficiencN
Infiltration
Windows
7- 7
,C-0-01ing Loads
A '
rea.: StUh ,-%
of load,:
Wall 1042 4
7-777........
C eil tnq....:
t
Windows 15150 58.6
'nk
54,
r
b a il
Latent Infiltration
2815 10.9,
Internal 1178
.........
Latent People Load 483
-7
777'77,�"
j
TO
25856
0
,sensible, 1-bad 22558
..............
...........
Latent load 3298
.............. ...........................
SHR 0.81
...........--1--,........ .............. ...........
Capacity at .75 SHR . 2.51 Tons
........... -------- .................
Cooling Loads
25,856 BTU/hj-
Sensible P le Load
L:toepnt People Load
f-Ceiling
Wall
Internal
Sensible infiltratior,
System Efficienc!
Windows
Latent infiltration
t
4.
ere
AED Graph
30000
20000
M
10000
0
8arn 9arn 10arn 11arn 12prn 1PM 2pm 3pm 4prn 5pm 6prn 7prn sprn
=Hourly Loads Average
iiACCA Manual S
System equipment selection will be made using the following Manual S derived values,
Summer Outdoor 930F
........................ ................. ................. ............... ............... ............. ..........
Surnmer Wet Bulb
770F
..............r............ ............................................................. ...................
Summer Indoor 750F
---1.1-..............................- I-- --.................... .......... ...................
Summer Design, Grains 50%
..........................
'' "'' . :,-*... ........ ................... ................ .......... ................................
Winter Outdoor 320F
............ ........................ ....... .............. ..................................................................................... ..................
Winter Indoor 70"F
....: ........................... ......................... .............................................. .................... ..................
Sensible Cooling 22,558 Btuh
.................... .................... ................---........................................
Latent Cooling, 3,2 1 98 Btuh
.............---.......... .......... .......................................... ...... ............................ ........ ...............
Required Cooling Airflow 1,025 CFM
............. ........... ..................... ................. ................... .................................
Sensible Heating . 25,002 Btuh
----...................-.1 -- I.- I I.: -.............- .................... .......... .111-1--.111------------------........--------..........
Required Heaing Airflow 325 CFM
-1-1--............ ................. .................... .....--------------------------*--------------------
All calculations are based upon approved hvac industry standards and procedures,and comply with all local,
state and federal code requirements.All computed results are Estimates,Product provided by Energy Design
Systems and Idea Tree