Loading...
Permit HVAC 1085 Atlantic Blvd 79 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 A Application Number . . . . . 12-00001423 Date 10/02/12 Property Address . . . . . . 1085 ATLANTIC BLVD 79 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/31/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRFSS: I &Wk;,=�ERMIT# PROJECT VALUE .R. ;Z,11 7- 7;2. , '!./ ARI# t4 7 000 2--7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating_ Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit .2- %/7- Heat: Unit Quantity BTU's Per Unit 5 K Li Seer Rating Duct Systems: Total CFM 15 REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The pen-nit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company7RU-A K,&-(S kt—cAnlr,�0�1 (Aa&-�ficle Phon&5- Co. Address: -47,Z'A., 0111 PL X-e2A — 1.j City LQ-Lad"j State F/ Zip35Vn. License Holder (Print): �rr I I E,-RannQIS Statf. ification/Registration#d4fb 4/-//60 Notarized S��qtu i4JR!LEY L.GRAHAM "�)i,�ISSION�DD 95 d ibed before nAe-tRs7). day 20 an 2�*14 Feioruafy 14,Z ure of Notary Public —T— CERTIFIEDT. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy byAHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously pu,blished data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representation,$,warranties or guarantees as to,and assumes no responsibility for, the product(3)listed on this Certificate.AHRI expressly disclaims all liability for damages of. y kind arising out of the use or performance of the product(s),orthe unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,In whole or In part,be reproduced;copied;disseminated;entered Into a computer database;or otherwise utilized,In any form or manner or by any means,except for the user's Individual,personal and confidential reference. CERTIFICATE VERIFICATION The Infbrmation forthe modelcited on this certificate can be verified atwww.ahridirectory.org, it Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was Issued,which Is Hated above,and the Certificate No.,which Is listed below. a," an ILI and Refrigeration Institute 02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 DesignStar Load Calculation Results are intended for use with Rheem heating and cooling sy3terns only 'rho Now Degroo of CwOoftlu C ustomer Information 7 L ocation: ................ ......... Street Address 1080*Atiantic blvd, DUVAL FL 32233 L tude,Longitude 30.33750 -81.7686' atit .......... ...... ............ House Square Footage: 10.50 sq. ft. .................................... ........... .......... Name:. Terry Runnels .......... ........... ................. Phone: 863-581-4268 ............. ......................... Email: terunsr@aol.coni .............. ................... ..............-....................................... ..................... 'House Information SH R 75 ............................................ .................................................... ................................ ............... ............. ................................. Number of residents 4 .......... .......... ......... ---------- ........... Ceiling height 8 ............. ................. ....... Wall. U-value R-value 0.00111 ........................................... .......... ................. Floor U-value R-value 0.2 15 ............... ................. ................. .......... .................. ............ Ceiling U-value I R-value 0.05 ,1 19 ............................................. ....................... Window U-value .............. ---------- ............. ------------- ......------- 7 Window SHGF 0.85 ..........---............. ............................... ............ ............... .............. .................. Moisture grains 0.85 Ductloss % 10 .......... .......... ................ .............. Duct gain % 10 .................. ............... ........ Cooling infiltractio'n (ACH) 0.6 ............. ................. ............ ............... ............. ............................ ............. Heating infiltration (ACH) 0.8 .......... 'Winter ventil at!on: ...................................... ...................................... Summer ventilation 0 Design Conditions; Outdoor Heating Cooling ---------------- .................... ................ Dry bulb (OF) 32 93 ............... ...................................... ........... ............................................ .............. ..................... 1-1.................... Daily range M .................. ................... 7---------------------------*................... Relative humidity : 50% .............. .......... .............. .......................... .......... Moisture difference 53 ............. .................... ........................ ................. ........... ..................... ........... ............... ............. Indoor Heating Cooling .................-..............- I.I.-I..-............ ........... Indoor temperature (OF) 70 75 , ...........I I-- 1 11..........- ........ ............... ................ .......... Design temperature difference(OF) 38 18 .............................................-- ...................................... ..................... ................................................................. .............. Loads Area Btuh % of load .................... .......... Wall 2201 8.8 .......... Floor 7980 31.9 ........... ................................................................ ......................... Ceiling 2115 8.5 ............ ------ .......... Windows 6080 24.3 .............. ....... .......... ......................... Infiltration 4354 17.4 ................. ...................... .......... ............ System Efficiency Loss 2273 9.1 .......... ....................................... ............... Total: 25002 .............. ............- ....................... Heating Loads 25,002 BTU/hr C .1. ei Ing Wall Floor System Efficienc� Infiltration Windows :C o 0 1 i n a d S 7777: ti YC f I aid, AT' ea,_� t 9 - 0 ........... wall 1042 4 9, ex n 002 � 3_ .......... Windows . 58.6 7� 7-, S si I fil ti 1j't Latent Infiltration 2815 10,9 7,7, �777� ;7_7 777�7` 7Ci7 4" Internal- 1178 4.6 7,, ibl'.Ro LOM',K,"� 1.9 ............ Latent People Load 483 ................. T6tal:� i5� 56 ,1- Sensi bl'e f66' d '�58 .......... .......... Latent load 3298 .......... ............. ............ ............. ............ SHR 0.87 ............ ........................ ............. Capacity at .75 SHR 2.51 Tons Cooling Loads 25,856 BTU/hr SensibI P ople Load Latent People Load r-Ceiling Wall Internal Sensible Infiltratior SYstem Efflcienc,� Windows Latent Infiltration AED Graph 30000 20000 10000 0 8arn 9arn 10arn 11arn 12prn 1PM 2pm 3prn 4pm 5prn 6prn 7prn Bprn Hourly Loads Average 'ACCA Manual S System equipment selection will be made using the following Manual S derived values, Summer Outdoor 930F ............... ...............- .......... ................................... Summer Wet Bulb 77"F .................. ................................ .......................................... ...................................................-.......... .............................. Summer Indoor 750F .......... ............. ..........................- .......... Summer Design Grains . 5o% ........... ............. .............. .............. .......... ............ ................................ Winter Outdoor 320F ........... .............. .................... ............ ........- - ...... ............... Winter Indoor 70OF .................. ............................. .............................-................. ...................... ........................... Sensible Cooling 22,558 Btuh ................... ..........-....... ........................... ........ Latent Cool i ng, 3,298 Btuh .......... ............. ......................... ....................................._..'................ ................... Required Cooling Airflow 1,025 CFM .............................. ............ .......... ........................................ ....... ...... ...........1-................... Sensible Heating . 25,002 btuh ............. Required Heaing Airflow 325 CFM ................ .......... ............................. All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree