Permit HVAC 1085 Atlantic Blvd 59 2012 1A CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001435 Date 10/09/12
Property Address . . . . . . 1085 ATLANTIC BLVD 59
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
1085 ATLANTIC LLC RUNNELS AIR CONDITIONING
5118 N 56TH ST 4222 CINDY RD
TAMPA FL 33610 LAKELAND FL 33810
(863) 581-4268
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . valuation . . . . 0
Expiration Date . . 4/07/13
------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILD jNG CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904)247-5845
JOB ADDRESS: A -Btvd . AAadfi(,��M&4�ZERMrr#
PROJECT VALUE $--- ;?,j 7- 7Z , tL/ A RI# 14, -7 0(19 0
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's PeT Unit Seer Rating_.....
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit .Z -
Heat: Unit Quantity._... BTU's Per Unit 5 K LJ Seer Rating 16
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Firei Sprinkler System Quantity (Requires 3 sets of plans)
Firej Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fir&�Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Firel Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Pref!4bricated Fireplace Qty_ Automobile Lifts
Gas i Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vonted Wall Furnaces Refrigerator Condenser BTU's
4 Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER.-
Permit bec*es void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have re-a-i
this applicajion and know the same to be true and correct. All provisions of laws and ordinances governing this work-will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
PropertylOwners Name Phone Number
#
MeehaniW Company-ALL A n%0-(S kr` 1,4=P1,r AQ cxr-�*Cle Phon&3-5SI y0/,R-77Y.
Co. Add;ess: 1 ORC=j City-L&kAJjq-o State F/ Zip,;J�
License 11older(Print): —tvew-rr L-t &-Ranrt Statwartification/Registration 4C*tQ 4�1160
NotarizeO Signature of License Holde
cHIR�EY L.CIRAHAM rn and4odo�/ihsyribed before yCe t s 20g
�0` MYCO,
M" nature of Notary Public
'10N�or,96776
14,20
ES:FPbruary 14,20
t�ot.ary Public UnlerW
Iters
C FIEDT
ERTI
www.ahridirectory.org
Ceftificate of Product Ratings
AHRI Certified Reference Number: 4765491 Date: 9/10/2012
Product: Split System:Air-Cooled Condensing Unit, Coil with Blower
Outdoor Unit Model Number: GSX130241C*
Indoor Unit Model Number: AR*FI82416C*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trsde/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 23000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Ratin s followed by an asterisk indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCOMER
AHRI does not enclorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the p*uct(s)listed on this Certificate.AHRI expressly disclairris all liability for damages of any kind arising out of the use or performance ofthe product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configuraltions listed In the directory at www.ahridirectory.org.
TEROS AND CONDITIONS
Thl C rt' - ri�ft contents are proprietary products ofAHRI.This Certificate shall only be used fbr Individual,personal and confidential reference purposes.
is
Th,c,Fn=of1h Certificate may not In whole or In part be reproduced;copied;disseminated;entered Into a computer database;orotherwise utilized,in any
form manner or by any nwans,except for the user's Individual,personal and confidential reference.
CERT FICATE VERIFICATION
Thein rmation for the model cited on this certificste can be verified at www.ahridirectory.org, Air-Conclitioning,Heafing,
click 'Verify Certtlificate"link and enter the AHRI Certified Reference Number and the date on
0%2 an IL ut
which he certificate was Issued,which Is listed above,and the Certificate No.,which Is listed below. I and Refrigeration Institute
020�12 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917765623209026
IL
_J
DesignStar Load Calculation
Results are intended fbrusewith Rheern heating and cooling systems only
rna New Diogree,01 COWOnTI,
�customer Informatibn
toicatilow:
............ ......
Street Add res s 1088 Atlantic blvd, DUVAL, FL 32233
.............. ......w................................... ............
..............
(Latitude, Lonaitude 30,3375', -81.7686
.............. ..........I.......... .......... ...........
................................ .............. ............. ..........
House Square Footage: 825 sq. ft.
...........-------- ..........-,-.............................. ...................................... .............. .................
IName: , Terry Runnels
..................
............ ....... ............
jPhone: 863-581-4268
.......... ..........------- .......................... ................................... ...................................
,Email:
terLinsr@aol.com
............... .............................. ............... .............. .................-
flouse Information
�HR .75
............ .................................................... ................. ..........
u m b e-r- f r-e-s'-i"d--e--n'--'t"-s ................................................. 4,
............. ..............................----........................... ............................................... ............-..............
Ceiling height 8
------------- ........ .......-.............. .............. ..........
�all U-value I R-value 0.091 11
....................I................ .......... .......................... ................... .................. .............
F, loor U-value I R-value 0.2 15
...............-....................... ...... ............. ............... ............ ............ ...............
Feiling U-va.lue I R-value 0.05 119
... ...............— .. .................. .......... .......... .............................................
Window U-value
nclow SHGF 0.85
----------- -------------------------------------------..................... --------------- ............ .......................
..........-1-d-............... ................. .......................... ........... ......
M, oisture grains 0.85
b ................--I.----....I.............. ...................... .............. ........... .............------------------------- ............ --------
uct loss 0/0' 10
................................
.............. ....................................... .............. ............... ..........
Duct gain % 10
.......... ...... ............. ---------------------- ..........
oo ing infiltraction (ACH) 0.6
............... ........... .......................- ..................... ..........
...........
Heating infiltration (ACH) 0.8
.........................
inter�ventilation
. ........... ............................ ........... ..........
................. ..................................... ............
ummer ventilation 0
,;Design Conditions
Outdoor Heating Cooling
'Dry bulb ('F) 32 93
........... .................... ............ ..................- ..........................................-............... ..................... ...................... ................. ............
Daily range M
.......... ............ .......
Relative humidity
50%
.........................................;............ ......................................... .......... ..................................-
Moisture difference 53
.......... ..........................................................................................-..-.......................... ........... ...............
Indoor Heating Cooling
............ .......... ......... .............. ........................ .......................................... ----------- ..........
Andoor tem erature (OF)
p 70 75
.............................. ............ ............ .................. .......................................... .......... ..................
..........I..........
Design temperature difference('F) 38 18
............. ......................... .................................................. ............. ....................... ........... ...........
Heating Loads
Area Btuh % of load
.................... .......... ..........
Mall 1951 9.6
............... ---------- ....... ................... ................. ..........
,Floor 6270 30.9
.............. .............. .............................
teiling 1662 8.2
..........I...........
Windows 5168 25.4
.............. ................................ .....................................I..................*........
Ill-ifiltration 3421 16.8
............................-.......... ..........................
System Efficiency Loss 1847 9.1
............... .................................. ............ ......................... ..........
Total: 20318
------------- ----------- ...... ................... .................
H eating Loads
20,318 BTU/hr
Ceiling
System Efficiency Loss
Floor
Wall
L
Infiltration
Windows J
r
Loads
,Cooling
I Area 13tuh % of load
-3
V ad 924 4,'d
T,
ceiiing 787 3,7
101i t d ows 12789 593
.... .......
Sensible Infiltration 12 IL 5 5�7
Latent Inf Itration 2212 10.3
S y s t e m E ff i c i e n c y G a i n 1 7 93 8 A
926 43
Sensible People Load 380 1�8
.......... .... ..
Latent People Load 380 1�8
To ta 1: 21405
Sensible load 18813
Latent load 2592
lsllr� 0,88
kapacity at 35 SHR 2.0 9 'Fo rvs
Cooling Loads
21,405 B'TU/hr
Sensible People Load
Latent People Load
Ceiling
Wall
Internal
Sensible Infiltration
System Efficienc,
Windows
Latent Infiltration
AED Graph
20000
15000
10000
5000
0 8a m 9am loam Ilam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8Pm
�_---Hourly Loads Average
1,ACCA Manual S
System equipment selection will be made using the following Manual S derived values.
Summer Outdoor 930F
.......... ...... ........... ......... .............-
�ummer Wet Bulb 770F
............
'Summer indoor 75OF
..................... ............ .............
ummer Design Grains 50%
................. ............... ................................. ...................
.......... ................................
Winter Outdoor 320F
.......... ........... .............. .................. .......................--.................
�Vinter Indoor 70OF
................................... ...........
Sensible Cooling 18,813 Btuh
..............*............................ ........................ ..................................................................... .........I'll",---------
Latent cool i ng 2,592 Btuh
...................... ................... ...................... .......... ....... ................... ..........................
lRequired Cooling Airflow 855 CFM
-.1------------ .........-.:........................... ..................................-------- ........................................ ........................
�ensible Heating, 20,318 Btuh
.......... ........... .................. ............. ..............
P,equired Heaing Airflow 264 CFM
i
--------------- ---------------- .......... ................ ..........
All calculations are based upon approved hvac industry standards and procedures,and comply with all local,
st�te and federal code requirements.All computed results are Estimates,Product provided by Energy Design
S�stems and Idea Tree