Loading...
Permit HVAC 1085 Atlantic Blvd 61 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001432 Date 10/09/12 Property Address . . . . . . 1085 ATLANTIC BLVD 61 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . valuation . . . . 0 Expiration Date . . 4/07/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904)247-5826 Fax (904)247-5845 JOB ADDRESS: PROJECT VALUE $—;Z,, 2- 7,-,�- A RI# 14 7 00C 2---7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating— Duct Systems; Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit .2, Beat: Unit Quantity BTU's Per Unit 5 Seer Rating_ Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipc Quantity — (Requires 3 sets of plans) Underground Fire Main Value — (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial floods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces RefrigeratorCondenser BTU's Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if woik does not commence within a six month period or work is suspended or abandoned for six months.J hereby certify that I have rea( this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. t /I Property Owners Name X-129,�da– Phone Number Mechanical Company'i9cLn nyo(s –WF E:WD — – (��I t ice PhoneRo,�� Co. Address: 4ZZ�� 0-,,-kLtjL/ 7;2 city odo-A State�F Zip---e9tL/) License Holder(Print):—t r-rLjE,7RLUnrt-e– 's S ification/Registration #01AL0 40 160 Notarized Signature of License Hol'de tn!t�,..�orn and s cribed be or m this er 20tZ <,PNR� -EYL.GRAHAM otary q�7KO Si atUre of P Ibli -,ivary'42014 EXPT�ES:FPL Notary Pijb�!�;U,A11IM4611 Certificate of Product Rati_n2s 1. 1 AHRI Certified Reference Number: 4765491 Date: 9/10/2012 Product: Split System: Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX130241C* Indoor Unit Model Number:AR*F182416C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endonse Ow product(iii)fisted on this Certificate and makes no representations,warranifies or guarantees as to,and assumes no responsibility for, die product(*)listed on this Certificate.AHRI expressly dischdrins all liability for damages of any kind afting out of the use or performance of the product(s),or the _11, of date listed on this Certificate.Certified ratings are valid only for models and configurations fisted in the directory at www.aheidirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products ofAHRI.This Certificate shall only be used for Individual,personal and confidential reference purposes. The contents of this Certificate may not,In whole or In part,be reproduced;copied;dissemilinated;entered Into a computer database;or otherwise utllb*d,In any form or manner or by any means,except for the user's Individual,personal and confidential reference. CERTIFICATE VERIFICATION The information forthe model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"fink and enter the AHRI Certified Reference Nun*w and the date on an ILI and Refrigeration Institute which the cerfificalawas Issued,which is fisted above,andthe Certificate No.,which Is listed below. 02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917765623209026 MINNIE esignStar Load Calculation suhs are intended lbr use with Rheem heating and cooling systems only T,10 Now 0091'oe,O'ComfolIP Ala— Customer Information ............. -DUVAL.. FL 32233 3 . L ng" tud 0 337 -o:81 7 86" .............. ...... ------------ ............... House-Squarefootage:.: 7,50 sq. ft. ........... ........... Name: TeTry Runnels .......... .......... ................... Phone: ....................................... ............. Email: terunsr@aol.com ........... House Information SHR 75 ....................7 ................. ...... ....................- NumberofTesidents. 41 Ceiling height 8 ------------------ Wall U-val 6,ef P,-val ue. .0.09, ........... ............ ............ ........... Floor U-value I R-value 0.2 5 ............ ........................ Ceiting: U-�va[uef R-v lue, 01,05_1 19� ............v-;.......... ................. .............. ........... ........................ ........... Window U-value ........... ................ .............................. Window. SHGF'�� 0 85 ................................ ............ .......... .......... ...................... Moisture grains 0.85 ........... ....................... ...... Duct loss OW I G, ....................................... .................... .......... ................ ................. ..........................................................................-.................. Duct gain % 10 ............. ............. ................. ---------------- 0 6 C.061 ina �i rifli tr tion� WRY: D Re .................................. . I..... Heating infiltration (ACH) 0.8 ............. ............. Wintervenbiation .............. ............ ............ ............. Summer ventilation 0 'Design Conditions Outdoor Heating Cooling .................... Dry bulb ('F) 32 93 ......................... .................................. ........... Daily range M ............. ..........------7------------7.......................... ............. ........... .......................... Relative humidity 50%; ................. ................... .................. .......... Moisture difference 53 ............................................................ ............ ................................. ................................... ................. Indoor Heating Cooling ................ ............. ......... ...... ....... indoor temperature (ITY 70 .................... .......... ........... .............. .......... ........... ........... Design temperature difference(T) 38 18 ............ ............. ........................ ........... ................................................................................................... ........... ........... �:Heating Loads Area Btuh % of load .......... Wall 9.7 ............ ........... Floor 29.9 ............. ................. ............. .Ceiling 1511 7.9- Windows 5168 27.1 ......................... ................. Infiltration. 3110: 16.3 -------------............. System Efficiency Loss 1735 9.1 ........... Total: 19083 Heating Loads 19,083 BTU/hr Ceiling System Efficiency Loss Floor E', 121,, Wall 2 Infiltration V Windows J 711 1 7-1 71 T,7-17- 7,77 7777 77:75 1 �Cooling Loads .......... R, �E . . ........ Latent]bad, Ca a�jty bit:J5 SH R'�',, Ton S Cool i ng Loads 20,783 BTU/hr Sensible People Load Latent People Load Ceiling Internal Wall Sensible Infiltration: System Efficienv' Windows Latent Infiltration �Adequate Exposure Diversity AED Graph 20000 15000 10000 5000 0 8arn 9arn 10am 11arn 12pm 1pm 2prn 3prn 4prn 5pm 6prn 7prn 8PM HourlK Loads Average CCA Manual S iA System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F .......... ............. ............. .............. ............... Summer Wet Bulb 770F ............. ..............- ............ ...................- ............................. ............ .................. .......... Summer Indoor 750F ---------- ................ .......-------------- Summer'Design Grains 50% , .............--............................. .............. ................ ........................... Winter Outdoor 32"F ................. ............ ---------- Winter Undoor 70:017 ..................... .................. ........................ .................. ............................. Sensible Cooling 18,427 Btuh 7 ........ ........................... ................ Latent Cool i rig 2,356 Bfuih ...................... ..................... .............................................................. .............. ............................... ............. ........... ....................... Required Cooling Airflow 838 CFM ........................ ........... ............... .......... ........... ...... Ing Sensible,,H:eat' 1.9,083 Btuh ........... ...... .......... ............. ............... ...... Required Heaing Airflow 248 CFM ................ ...............................-......... ................... .......... ...............-............. ........................ All calculations are based upon approved hvac industry standards and procedures,and,comply with all,local, state and federal code requirements-All computed results are Esti,mates,Product provided by Energy Design Systems and Idea Tree