Permit HVAC 1085 Atlantic Blvd 67 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001426 Date 10/09/12
Property Address . . . . . . 1085 ATLANTIC BLVD 67
Application type description MECHANICAL HVAC ONLY
Property zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
1085 ATLANTIC LLC RUNNELS AIR CONDITIONING
5118 N 56TH ST 4222 CINDY RD
TAMPA FL 33610 LAKELAND FL 33810
(863) 581-4268
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 4/07/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION 47-47
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)247-5826 Fax (904)247-5845
JOB ADDRESS: 3724:0ERma#
PROJECT VALUE $ A,' .j 7- 7 Z , tl —7- ARI# 14- 7 DeDO 2--7
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit ;-) -
Heat: Unit Quantity I BTUs Per Unit-5 K LJ Seer Rating I b
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
4 Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have rea(
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work-will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance ofconstruction.
Property Owners Name Phone Number
Mechanical Company ALL tin to-Ls ax 4.3-771?.D
Co. Address: 4ZZA, 0-,ik4u ,�RC=4 City LaLL81AO State EL zip-:;s&n
License Holder(Print): t A-- r ja E,-R an rteLs State ification/Registration#CA-eZ 4�1160
Nota Siznalure ofLicense Ho
sHjp.,�EY L.GRA, is day o C7 20
sSION#DD 957790 ore
My Co�,,,Mjs orn and su scribed bef
:�j EXplpt-�&,Fabrdal"Y 14,2014
BondeilThru Notery Public underviriters gnature of Notary Publi
CERTIFIED
www.ahrid i rec to ry.or TM
Certificate of Product Ratings
AHRI Certified Reference Number: 4765491 Date: 9/10/2012
Product: Split System:Air-Cooled Condensing Unit, Coll with Blower
Outdoor Unit Model Number: GSX130241C*
Indoor Unit Model Number: AR*F182416C*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 23000
EER Rating (Cooling): 11.00
SEER Rating (Cool.ing): 13.00
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)liarted on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages ofany kind arising out ofthe use or performance ofthe product(s),orthe
-no ith-rtrad-ftration of data listed on this Cartiftate.Certified ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Cortificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and confidential reference purposes.
The contents of this Cartifleate may not,In whole or in part�be reproducedl;copied;disseminated;entered Into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the usees Individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The Information for the nnodel clited on this certificate ran be verified at www.ahridirectory.org, Air-Condifioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on 00 ILI and Refrigeration Institute
which the certificate was Issued,which Is listed above,and the Certificate No.,which Is listed below.
02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917765623209026
DesignStar Load Calculation
Results are intended for usewith Rheern heating and cooling systems only
'No Now Dogtoo of CoWort�l
'Customer Information
77�,7777777777
Lota lon:,
..........
Street Address 1088 Atlantic blvd, DUVAL, FL 32233
..........................
Latitude, Longitude 30.3375'r -81.7686
............ ........... ......................... .............- ............. ..................- ..........
House Square Footage: 825 sq. ft.
..........- .......... ............ ............................... .......... ....................
Name: Terry Runnels
............. ..........-...................................-............................ ......- .............. ...................... ..........................
Phone: 863-581-4268
............. ............................... ------ -------
Email: te,runsr@aol.com
............. ............ .................................. ..............................
iiHouse Information
SHR .75
............... ........... ............................ ............................... .......
Number of residents 4,
............
Ceiling height 8
................ ................ ....................................................................... .............. .............. ............................
Wall U-value I R-value'- 0.091111 ,
..................... ............. ............... .......................................... --............. ..........
Floor U-value R-value 0.2 15
.....------ .......... ................. ........................... ..........................
Ceiling Q-value I R-value 0.0,5 ,119
.............1.................-.......... .................. ............--....................................... .................................. ....................................
Window U-value
............... ..........
Window SHGF. 0.85
.............. ..................................
........................ ................
Moisture grains 0.85
.......... ................................................................................ ......................... ..............
Ductloss % 10
......................................................................... ................ .................- .............. ..........
Duct gain % 10
..........I........... ....... ........ .............. ..................... .........
Cooling infiltraction (ACH)
..........
.............. .......... ...............................................
Heating infiltration (ACH) 0.8
............ ........... .........
"Winter:ventilation
0
............... .......... ........... .............
Summer ventilation 0
Outdoor Heating Cooling
Daily range M
Relative humidity 50%
Moisture difference 53
Und��� H��� Cooling
Indoor temperature (OF) 70 75
Design temperature diff2[en[e('F) 38 IA
--_'-_---__-..........._........... .........................................................._ ..........-......................................... -..........................____._---...............................................
`
'
`
`
Loads
Area Btuh % of load
................. .................
wall 1951 9.6
............... ............. ......
Floor 6270 30.9
............. ........... ......
Ceiling 1662 &2
............ ....................
Windows 5168 25.4
............. ........................................ ............................. ....................
Infiltration! 3421 16.8
......................... ..........
System Efficiency Loss 1847 9.1
........... ............ ..............
Tota 1: 20318
............. ...........
Heating Loads
20,318 BTU/hr
Ceiling
System Efficiency Loss
Floor
Wall
Infiltration
Windows
'Cooling
loads
Area % ,0 load
wall 924 4.3
................... ------
Ceiling 787 3.7
Windol.pjs 12789 59-7
Sensible Infiltration 1215, 5.7
Latent I n'111 Vati on 2212 10.3
' -19-3
A 8.4
systen-ft-ft ien
i n!I-.e r n, a 1 926 43
.......... ..7
Sensii5le Peo I L -1,80 1.8
p 'e Ld
............. ....................
Latent People Load 380 i,8
Total: 21405
............. .............
Sensible load 18813
Latent load 2592
SHR 0,88
Capacity at .75 5HR 2.09Tons
................ ..........
Cooling Loads
21,405 BTU/hf,
Sensible People Load
Latent People Load
Ceiling
Wall
Internal
Sensible Infiltrabon
System Efficlenc,
Windows
Latent Infiltration
A ri q le
guat Exposure Diversity
AED Graph
20000
15000
10000
5000
0 8a m 9arn 10arn 11arn 12prn 1pm 2pm 3pni 4prn 5pm 6pm 7prn 3PM
Hourly Loads Average J
1,ACCA Manual S
System equipment selection will be made using the following Manual S derived values.
Summer Outdoor 930F
............. ................ .......... ................ ............ ....................
Summer Wet Bulb 770F
.......... ........... ............. ............... ............... ...............- .......................... ............
Summer Indoor 750F
...................................
Summer Design Grains 50%
....................................... ............ ................................................. ................................. .............................
Winter Outdoor 320F
....................... ............................7--.............. ............... .................
Winter Indoor 70OF
................. .................................... ............. .................................. ............--......................- ................................
Sensible Cooling 18,813 Btuh
.................. .............. ........... --.11.1---........... .................... .......................
Latent Cool i ng 2,592 Btuh
.......... ............ ......................... ............................ .................................................
Required Cooling Airflow 855 CFM
--.1...........I ................................. ............. .......................... ....................... ......................
Sensible Heating 20,318 Btuh
............. .......... ...... .............11..............
Required Heaing Airflow 264 CFM
------------------------- ...............-................... ......................------- ..................................
All calculations are based upon approved hvac industry standards and procedures,and comply with all local,
state and federal code requirements.All computed results are Estimates,F�oduct provided by Energy Design
Systems and Idea Tree