Permit HVAC 1085 Atlantic Blvd 76 2012 SS CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001519 Date 10/16/12 Property Address . . . . . . 1085 ATLANTIC BLVD 76 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/14/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION 43o7-74 CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904)247-5826 Fax (904)247-5845 JOB ADDRESS: -z� A�Lo-mt-,',- AAat&L,�M_kTa-2e2PERM1T# PROJECT VALUE$—j&f 4_-,7 7;-1, A RI# 14 7 QeD C Z---7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratin- Duct Systems; Total CFM — REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit '2- - Heat: Unit Quantity BTU's Per Unit--5 K LJ Seer Rating. I Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Reffigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or%vork-is suspended or abandoned for six months.I hereby certify that 1-h=verea( this application and know the same to be true and correct. All provisions of laws and ordinances governing this work-will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance ofconstruction. Property Owners Name Phone Number Mechanical Compa-n-y,'jK-U--A. . n_y-0(- krl Co.Address: 4ZZA, city State F/ Zip3�Z,&,() License Holder(Print): —I rrLjE,74?-,u.nrte-j-,S State Certification/Registration#dAe-0 41/60 Notarized Signature of License Holder Sworn and subscribed before me this day of 20 Signature of Notary Public ru un*1 CE RTJ F1 E DTM: www.ahridirectory.org L 1� - -1; - �, : I I I �� A Certificate of P"roduct Ratings AHRI Certified Reference Number: 4765491 Date: 9/10/2012 Product: Split System:Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX130241C* Indoor Unit Model Number:AR*FI82416C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name:GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. 71SCLAIMER AMR[does not endorse the product(s)Rated on this Certificate and makes no representations,warranties or guararytess as to,and assumes no responsibility for, the product(s)listed on this Certificate.AMR1*xpreselly disclaims sit liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of dab Rated on this Certificate.Certified ratings are valid only for models and configurattions fisted In the directory at wwwahridirectory,org. TERMS AND CONDITIONS This Certificate and Its contents am proprietary products of AMRIL This Certificate shall only be used for Individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part be reproduced;copied,disseminated;entered Into a computer database;or oth"se utilized,In any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on Pam IBM ILI and Refrigeration Institute which the certificate was issued,which Is listed above,and the Certificate No,which Is listed below. 02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917765623209026 DesignStar Load Calculation Results are intended fbr use with Rheern heating and cooling systems only t-10 Now Dogroo of Comfort"' ilia Stre UVAL, Lcati .......... ....... ...... ............... House Square footage: 0 sq., ft.- .......... Name- :Terry Runnels ..................................... ........... ........................ .......... ........... ............ Phone: 863-581-4268 ............ ............ ........ ...... Email: terunsr@aol.com ............ ...... ....... ............ ................ Hou-se-Information -7 C; SHR .................. .............. .......... ............ Number'ofresidents 4 ............. ------ Ceiling height 8 ---------------- ...................----------—­..........------------- .................................. ................ ........... ...... Wall U-value P,-value 0.09 1 ............ ............. ...... .......... ................................................................................ .................. Floor U-value R-value 0.2 5 ..................... Ceiling U�valuej R-wvalue: 0.05 19 ............. .......... Window U-value ............ ............ ...................................... ............. Window SHGF 0.85- .............. ....................................................................... ................. ........... ...... Moisture grains 0.85 .......... ........... ........... Ductloss % ........... ........... ......................... Duct gain % 10 ............ .................. ....... ....... .................... ............... ----------------- ......... Cooling infiftraction (ACH) 0.6, .............. ..............-,-.................. ................................. .......... Heating infiltration (ACH) 0.8 Onterventilatio .......... ........... ........... .......... ........... ............ ........... Summer ventilation 0 ,I I ,Design Conditions Outdoor Heating Cooling ..................-......-........ Drybulb F), 32 ..........I...................... .................................... ....................................... ..................... ............. Daily range M .......... ............... ..................... ----------------- Relative humidity ......................................................... .......... .......... Moisture difference 53 ........................... .........................I......................................................................................................... ................................................................................ ............................... ................ Indoor Heating Cooling ............. ................ .............. ...... Iricloo.r.temperature, 715 ............................. z.......... ............. ............. ................ Design temperature differenceff) 38 18 .......................................................... ........... ........... ............. ..........................................................................................1.................................- 'Heating Load Area Btuh % of load ............. wait 1860 9.7 ........... ............ Floor 5700 29.9 ..............................---------- ....... .......... Ceiling 15,11 7.9 .......................... ------ Windows 5168 27.1 ...........I..................... ............... ..............--............ Infiltration 3110 16.3 System Efficiency Loss 1735 9.1 Totak 19083 ...................... ---------- Heating Loads 19,083 BTU/hr j-, Ceiling System Efficiency Loss Floor -i2 9 5, Wall K, j Infiltration Windows J tbolin-g- L-o-ads .......... ,.4 ............ U, Latent People Load 345- 13 ............... X, ............ .................�­ '89- �SHR C acity t 15, R.:, Z05 Tons ap a Cool i ng Loads 20,783 BTU/hr Sens ible People Load Latent People Load Ceiling Internal Wall Sensible Infiltration:' System Efficienci Windows Latent Infiltration Adequate Exposure Diversity AED Graph 20000 15000 5000 10000 -9 0 8am 9am loam llarn 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm Ho�HK Loads —Ave age ,ACCA Manual S System equipment selection will be made using the following Manual S derived values. Summer Outdoor 93"F .......... ....... ------------ ........ Summer Wet Bul'b 710F .................. ............. .......... ..................... .................. .......................................................... Summer Indoor 75`F ............ ................ ................................ ........... Summer Design Grairls 50% .......... ............. ........... ...................................... ....................................... ...........-..'........... ............ ................. Winter Outdoor 320F .......... ....... ........ ........................................ .......... ---------- Winter Indoor 70OF ........... ........... ............. ........................................... ....................... ........... Sensible Cooling 18,427 Btuh .................. .......... ..........-................................................... LatentCoohlng �. , 2,356 BtUhl .......... .......... ..................................... .................... ........... ................ ................. Required Cooling Airflow 838 CFM ................. ......... ------...... Sensible Heating 1.9,08,3 Btuh� .............. ....... ........... .......... .............................. ..... ......... Required Heaing Airflow 248 CFM ........... All calculations are base I d upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates,Product provided by Energy Desl Ign Systems and Idea Tree