Permit HVAC 1085 Atlantic Blvd 72 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001515 Date 10/16/12
Property Address . . . . . . 1085 ATLANTIC BLVD 72
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
1085 ATLANTIC LLC RUNNELS AIR CONDITIONING
5118 N 56TH ST 4222 CINDY RD
TAMPA FL 33610 LAKELAND FL 33810
(863) 581-4268
----------------------------------------------------------------------------
Permit MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 4/14/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOBADDRESS: Le2L�.�5:
-,3�ERMTT#
PROJECT VALUE $—j��2- 7 A RI# 7 DO C, Z-7
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Ratin-
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating--j_b
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Spritild er System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity — (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity — (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work-does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I ha
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work-will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name X vmes I " Phone Number
M ech an i c al C om panyTj�i�/i %0-(s kr-ect,�;�rt 40/v't r14A Ctr�*e Phona3- Aa-�M3-77,?.�7,
Co.Address: 4ZZ�Z, 0-,i'PLLj city ���J—State F/ ZiP38 CtC
License Holder(Print): rrLj l&j-RL.Lnn-e15 State Certification/Registration#(jAfQ 44/60
Notarized Signature of License Holder
Sworn and subscribed before me this day of 20
Signature of Notary Public
C E RT I F I E DT11 J
wwv.!.a hri d ire c to ry.org
Ceftificate of Product Ratings
AHRI Certified Reference Number: 4765491 Date: 9/10/2012
Product:Split System:Air-Cooled Condensing Unit,Coil with Blower
Outdoor Unit Model Number: GSX1 30241 C*
Indoor Unit Model Number:AR*FI82416C*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name; GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows In accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 23000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Ratings followed by an asterisk(*)Indicate a voluntary rerate of previously published date,unless accDrnpanied with a WAS,which fndk&es an involuntary rensts.
DISCLAIMER
AHRI does not endorse the product(t)lided on this Certificate and makes no representations,warranties or guarantees 38 to,and a-u—no responsibility ft
On product(*)listed on this Cordficide.AHRI expreselly discialms all NabillAy for dernages of any kind arising osA of the use or performance ofthe product(s),or the
unauthorized alteration of daft listed an this Cordficato.Certified ratings are valid only for models and configurations Rated!In the directory at wwwahridirectory;org.
TERMS AND CONDITIONS
This Certificate and Its contents am proprietary products of AHRL This certificate oball only be used for Indbridual.personai and cofftlentlal reference purpos".
The contents of this Certificate may not,In whole or In pot be reproduced;copied;disseminated,entered Into a computer database;or otherwise utilized,In any
form or manner or by any means,exceo for the user's Individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The Irdormadw for the model eked an this certificate can be vonifled at wwwAhridirectory.org, A "IMF, Air-Conditioning,Hecifing,
click on"Verify Certilicate"Ilnk and~the AHRI Certified Reference Number and the dab on A04W 00 ILI and Reffigeraflon lnsftte
which the coteftaft was issued,which Is Ndad above,and the Certificate No.,which b Noted below.
02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917765623209026
DesignStar Load Calculation
Results are intended fbr use with Rheern heating and cooling systems only
T'w M;w OoqiOl GotnOr"
tustomer Information
Location:
Stre-et Address -1.088 Atlantic blvd, DUVAIL, FI- 32233
I-atitude, L,ongitUde 30,33'75�', -81,7686"
Sf--, a,e Foolaqe
750
N a rn e: Te�,ry Runneis
Ph,on e: 963-5181-4268
E e r u,r s r 1'-61)a ol I o i i
'House Information
SF,
l� R
Nul-nber of residents 4
Cf-Jhng h6ght
WaH U-ValUe R-value mg 1 11
Hour U-value R-valUe (12 5
Ct�,,illing U-value R-value a()5 1 n
Wind(,-,�,%, ti-value
Window -SHGF 0-85
M-0-6,snure wains 0�85
D t I c t I S % 10
Duct gain 10
Cooling infiltraction (ACH) O�6
Fleating infiftration (ACH) M
Wint(IT ventilation 0
SLVIffTlel- ventilation 0
'Desiqn Conditions
Outdoor Heating Cooling
D1,y 3,2 93
m
Rc�l�.,tive IhLiMidity %
difference 53
Indoor Heating Cooling
7t_) 75
38 18
iHeatin Loads
Area Btuh % of load
118160 9,7
F i i.-)or 5700 2 91 9
Ce!I in g 15 11 '7-9
n 0,0�s 2 7.
Dot-, 3110 i 61,3'
Systenni, Efficiency Loss 1735 9,1
"T 0 t a 1,9 0 8331
H eating Loads
01!31 3 B r Ul/
Ceiling System Efficiency Loss
Floor
Wall
Infiltration
Windows
:icooling Loads
Area Btuh % of load
VVii i 1 8 85 1 4.2
Ceiling 716 3A
ft n d ovvs 12789 6-1,5
1.11 1 -�.111. 1 1-1.............
Sensible Infiltration 1105 53
[,..a�U-�,nt infiltratkon 2011 9.7
Sys I,em Efficiency Gain 1750, 8.4
mi-ernal 842 4
.Sensible People Load 345 1,7
Later'lt People Load 345
Total: 20783
............
Sensible load 18427
Latent load 2356
SHR 0,89
Capacity at �75 SHR 2,05 *Tons
Cool i ng Loads
Sensible People Load
Latent People Load
Ceiling
Internal
Wall
Sensible Infiltration
System Efficienq
Windows
Latent Infiltration
�A equate Exposure Diversity
AED Graph
20000
10000
5000
0 3an'! Siam 10am I larn 12pm Ipm 2PM 3pm 4pm 5prT) 6pm 7pm 8Pm
Hourly Loads Average
ACCA Manual S
S';slom' equ;pn-l',�nl seiection will n1ade using the f(Acming Manual S oenved Values,
Su,n,1rTier Outdoor
!:_;jn'inr)er Wet Bulb 7 TT
.7,�'P
Sut-n;rner' Design Grains 50%
Ou't-fd('0I- 32T
Wiri�er Indoor 10"F
Btuh
,E)ensib�e Cooling
Latent Cooling 2,356 Btuh
Re'ClUired Cooling Airfllovv 838 CFM
Sensible Heat"Ing 19,083 Btuh
P
Reqt,i�ed Heaing Airflow 248 CFM
Ali c alc ulations are based upon approved hva(.. indusb-y stardards and procedures,and c'orlply WiLh all local,
state and ft,!deral code requirernents.All computed results are Estunates.Product provided by Energy Design
Systems and I(Jea Tree