Permit HVAC 1085 Atlantic Blvd 75 2012 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 12-00001518 Date 10/16/12
Property Address . . . . . . 1085 ATLANTIC BLVD 75
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
1085 ATLANTIC LLC RUNNELS AIR CONDITIONING
5118 N 56TH ST 4222 CINDY RD
TAMPA FL 33610 LAKELAND FL 33810
(863) 581-4268
----------------------------------------------------------------------------
Permit MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 4/14/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904)247-5826 Fax (904)247-5845
JoB ADDRESS: A�Lc,,t', —bt vj,. , 10 -Ta-�EPERMff#
PROJECT VALUE A RI# 1-4- 7 00
REQUIRED
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems. Total CFM REQ W-R—ED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity_I Tons Per Unit
Heat: Unit Quantity BTU's Per Unit
Duct Systems: Total CFM LU- Seer Rating__J,-'-'�
REQUIRED
IFIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
commercial floods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Reffigerator Condenser BTU's
Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if work
does not commence within a six month period or work-is suspended or abandoned for six months.I hereby certify that I have rea(
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work-will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name. I -).0 Phone Number
Mechanical Company-ALl
"I IF 140 Sq�W*cle PhonaZ-561- �EW3��77-?,
Co. Address: -47,Z,;t, k4ii ?�,C=ct city State Zip-;;Setn
License Holder(Print):71-';mr-r Lj ;G;,-R.Lt-nrte,j,S State Certification/Registration AlAem 44/60
1
Notarized Signature of License Holder
Swom and subscribed before me this day of 20
Signature of Notary Public
Certificate of Product Raltin!Rs
AHRI Certified Reference Number: 4765491 Date: 9/10/2012
Product: Split System:Air-Cooled Condensing Unit, Coil with Blower
Outdoor Unit Model Number:GSX1 30241 C*
Indoor Unit Model Number:AR*F182416C*
Manufacturer: GOODMAN MANUFACTURING CO., LP.
Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(13tuh): 23000
EER Rating(Cooling): 11.00
SEER Rating (Cooling): 13.00
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(*)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for;
the product(s)fisted on this Certificate.AHRI expressly disclaims all Itablifty for damages of any kind arising out of the use or perforrnance of the product(s),or Me
Karst n of data Nsftd on this Catruncatte.Cerfified ratings are vaNd only for models and configurations fisted in""directory at www.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and Its contents are proprietary products of AHRL This Certificate shall only be used for Individual,personal and confidential reference purposes.
The contents of this Certificate may not,In whole or In psr%be reproduced;copied;disseminated;entered Into a comiptder database;or otherwise utlltwd,in any
form or manner or by any means,except:for the user's Individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The Information for ft model cited on this Certificate can be verifled at www.ahridirectory.org, 04 "1311 Air-Conditioning,Heating,
click on"Verify Certificate link and enter the AHRI Certified Reference Number and the data on OME low ILI and Refrigeration Institute
which the certificate was issued,which Is IhAed above,and the Cerdflcata No.,which Is listed below.
02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 12991776562320
esignStar Load Calculation
Its are intended fbr use with Rheem heating and cooling systems only
Tne Now Degjoa of CoWoriTI,
'U
21
Customer Information
7-p --7
Street Address 1088 Atl an ti c b I vd,:,DU VAL, FIL 3.2233 , , ,
..........
Lati tud 6' Lor''
7 861,
gitude -81.
...........
House Square Foota
750 sq. ft�
................. --------7!
Name: �Terry Runnels
................................... ....................
Phone:
Email: terunsr@aol.cOm
.......... ......... ................... ................ .................- ................ ...........7 ................
'House Information
SHR -7 q�
.......... ............ ............. ...... ............
Number of residents 4
Ceiling height 8
.......... ......... ........... -------------- ------
Wall U-value, I R-value 11;.
............................. ............ .......... ..........-.......... ............ ...........- ................... .........................
Floor U-value R-value 0.2 5
........... ............. ....... ........... ........... ------- .......
Ceiling U,-valuel R-v4ue 0.b5l� 9
.............. .......................... .............- ............. ............... .......
Window U-value
.......... -------------....... ..............
Wi ndow SHGF
.......... ...... .......... ........... ......................................... ........... ............. ...........
Moisture grains 0.85
.......... ----------- ....................................-.......... .......
Duct I oss %
10::�
................ ......... .......... .............
Duct gain % 10
.............. ---------- ..................7 ............ ........................ ----------------
Coblina infi1tractiom (ACHY
D
Resu
..........I 1-1..� 1 !-�.� �: - 11 -,I
............ ..................... ...........
Heating infiltration (ACH) 0.8
.......... ................... .................... ..................
WintprventiJab-On. 0
.................
.......... ..........- ........................ ................... ....................
Summer ventilation 0
Design Conditions
Outdoor Heating Cooling
.....------------ .......
Dry bulb (OF) 32
93 :
. .......... .............. ... ........... ..............................................................................
Daily range M
..........-..-............ ......................................... ...... ............................... ------------ .......
Relative humidity.
5:0
.................... ........... .......... .................. ..............
Moisture difference 53
................ .......... ........... ........... ................................ ........... .......................................... ....................... ................................
Indoor Heating Cooling
................................. ...... ...... ...................
Indoor temperature-("'r) 70
- 75
....................... ........... ........... ..................................................... ........... ...........
..........
Design temperature difference(OF) 38 18
.............................. ................................................................................. ........................................ ............. ..........- .......... ............
Heating Loads
Area Btuh % of load
........... ............ ----------
Wall 1860 9.7
............. .............
Floor �5700 29.9
.......... -------------- ...........
Ceiling
1511 7.9
.......... ............ ......
Windows 5168 27.1
...........
Infiltration 3110 16.3
.....................
System Efficiency Loss 1735 9.1,
.............
.Total: -19083
..........
............
Heating Loads
19,083 BTU/hr
Ceiling
System Efficiency Loss
Floor
K�,
Wall
Infiltration
Windows
777',',
�Cooling 'Loads
........
...........
Late
M
Latent joad 2356,
...........
0 9
SH
�8
Capacit 35 SHR 2.05 Tons
ka,t
------------ ..........
Cooling Loads
20,783 BTU1hr
Sensible People Load
Latent People Load
r-Ceiling
Internal
N
Wall
Sensible Infiltratiom,
System Efficienci
Windows
Latent Infiltration
Adequate Exposure Diversity
AED Graph
20000
15000
10000
5000
0
8am 9am loam Ilam 12pm Ipm 21)m 31)m 4pm 5pm 6pm 7pm 8pm
Loads Average
iACCA Manual iS
System equipment selection will be made using the following Manual S derived values.
Summer Outdoor 930F
........... ............... ............. ............. --------
7
Summer Wet Bulb
775F
............ ............................... ...........
.................. ........... .......... .............
Summer Indoor 75`F
------------ ........... ........ ................... .......... ...................... ..............
Summer Design Grains 50%
............ .......................
................. ................... ...............
Winter Outdoor 32cF
............ ........... ........................
Winter I%ndoor
...............
.................. ..............
Sensible Cooling 18,427 Btuh
------------ .............. ............ ............ ...... .......... .............
'Latent Cooling 2 356 BtUh
............ ............ ...................... ..................................... ............- ............... ................
Required Cooling Airflow 838 CFM
..........
Sensible,Heating�
19,G813 Btuh
......... ------------- ......................--1- ................... .........
.............
Required Heaing Airflow 248 CFM
........... ------------- .................. ........................ .............. .....................
All calculations are based upon approved hvac industry standards and procedures,and comply.with all local,
state and federal code requirements.All computed results are Estimates,Product provided by Energy Design
Systems and Idea Tree