Loading...
Permit HVAC 1085 Atlantic Blvd 4 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ,oil Application Number . . . . . 12-00001582 Date 10/29/12 Property Address . . . . . . 1085 ATLANTIC BLVD 4 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu. ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 4/27/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION /2prV CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904)247-5826 Fax (904) 247-5845 JOB ADDRESS: -5( AA4j&&�004_ZZZ�SPERMIT# A tit, - PROJECTVALUE $ A RI# 14, 7 000 2--7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating 16 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have rea this application and know the same to be true and correct. All provisions of laws and ordinances governing this work-will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company 10.4.1 rilqC���ficle Phonc&Z-!�5L( ti K e—ej —yFra—x- Co. Address: 4ZZ'R, 0-..,1'kt ILJ .ty oL"l StateF ZiP3�� License Holder(Print): r 7PLLr1ft-9—LS State Certification/Registration#CA-to 4�//60 Notarized Signature of License Holder Sworn and subscribed before me this day of 20_ Signature of Notary Public Im C E RT'l F' E' D www.ahridirectory.org Cleftificate of Product Ratings AHRI Certified Reference Number: 4765491 Date: 9/10/2012 Product: Split System: Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX130241C* Indoor Unit Model Number: AR*F182416C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(13tuh): 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk()indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representation*,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expres*disclaims all liability for damages of any kind arising out of the use or perfiDnnance of the product(s),orthe unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at www.ahiidirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for Individual,personal and confidential reference purposes. The contents of this Certificate may not,In whole or In part be reproduced;copied;disseminated;entered Into a computer database;or otherwise utilized,In any form or manner or by any means,except for the user's Individual,personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was Issued,which to Rated above,and the Certificate No,which Is listed below. an and Refrigeration Institute 02012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917765623209026 DesignStar Load Calculation Results are intended for use with Rheem heating and cooling systems only Tn Q Now Ngtoo of CoWort" C t M us o e r' nfb r m a t i o n' Location: ............................ Street Address 1088 Atlantic blvd, DUVAL, FL 32233 .......... ............... --------------- ............. .......... Latitude, Longitude 30.3375 0, -81.76860 ................I.......... .............. ............................. ............................... ............... .......................... House Square Footage: 825 sq. ft. ............ ....... ............ ........ ............ Name: Terry Runnels ..............................------------............................................---................................................. Phone: 863-581-4268 -1-1---........... ............................................... ................. -.............................. ................................... .......------- Email: terunsr@aol.com ........... .............. ......-.11--........... .......... .......... .............. ......... HoUse, Information - SHR .75 ........................... ............................ ....................................................1----......'-------......................... Numberof residents 4 ..........................---................. .......................................... ..................... ................................. Ceiling height 8 --1--.................... ................. ...............................­­...... ...... --------------------..................................... Wall U-value I R-value 0.09111 .I.I.....-....................... .............................................................................................. ........................... ............--...............- ........... ........... Floor U-vaiue I R-value 0.2 15 -------------.......................................- ................... ......I--........... , Ceiling U-value I R-value 0.05 119 ---........................-.................................. .............----.....................-................................................-..................................................................................... ............................... Window U-value .......... Window SHGF 0.85 .................................. ..............-......- ............................................................. ........... .......... .......... ........... Moisture grains 0.85 I--............. ............... ------ Duct loss % 10: Duct gain % 10 .......... ....... ........... .........1--1-------.--- 1......... Cooling infiltraction (ACH) 0.6 .. ........ . ..... Heating infiltration (ACH) 0.8 Winter ventilation 0 Summer ventilation 0 Outdoor Heating Cooling ............... ............... ............ .......... Dry bulb ('F) 32 93 -1.1.1'..�.�............................................................... ...................... ............ ................................. .................................... Daily range M .................... ..........-............. ........... ............. ........---------- ------- Relative humidity 50% ................-- .............. ........................................................... ................ ..............................-........... ...............-..................... Moisture difference 53 ........... ............................................................................- .................................. ......... .......... ................................... ............................................. Indoor Heating Cooling .......................... ............. ........-........................... ........................ ------------------........... .......... Indoor temperature ("F) 70 75 ..1.1-1-...- .....................- .............................................................--............... ................................................ ........................ .......................I I. -.1-1- --.1-11".. Design temperature differenceff) 38 18 .............1- 1 1 1-..........I...................1- 1..............-.1.1-1................................................................. .......... .................... .......................................................................... 11 IN Area Btuh % of load Wal 1 1951 9.6 ....................................... ................. ............... ....... Floor 6270 30.9 ...................... ----------- Ceiling 1662 8.2 ............. ............... Windows 5168 25.4 infiltration 3421 16.8 ................ ................................ System Efficiency Loss 1847 9.1 ....................... ........ ............ Tota 1: 20318 ------------- .................................. Head ng Loads 20,318 BTU/hr Ceiling ... . .. System Efficiency Loss Floor Wall Infiltration Windows ---------- ra Me 11MOOM Area Stuh % of load Wall 924 4.3 .................. .......------- ---------- Ceiling 787 3.7 V'Ji n d o vvs 12789 59.7 Sonsible Infiltration 1215 5.7 I-aLent Infiltration 2212 10.3 ........... Systern Efficiency Gain , 1793 8.4 intermll 926 4.3 Sensible Peo Load' p ................ ................ I-alent People Load 380 1,8 Total: 21405 .................... ....... Sensible load 18813 Latent load 2592 SHR 0,88 -11.......... ......... Capacity at .75 SHR 2.09 Tons ............. Cooling Loads 21,405 BTU/hr Sensible People Load Latent People Load Ceiling Wall Internal Sens ibie Infiltration System Efficienc, Windows Latent Infiltration Fire M- 4 I-X r-A M, T09".FUZ 11 U=- AED Graph 20000 15000 10000 5000 0 Barn 9am 10am 11arn 12prn 1prn 2pm 3prn 4prn 5prn 6prn 7prn 8PM Hourly Loads Average ACCANanual S',..*-, System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F -1.....................I -...........I..,.--�..,-�..,.-...-...-�..-..--.�.�..................................-.......... ............. ...........- Summer Wet Bulb 77"F ..........-'-- : I --.............. .......... ..................1 1.1-1 -1.11 1.1- 1 tl-.- --- Summer Indoor 750F ............................. ................. ........... .......................... ..............--.......................... ......... Summer Design Grains 50% ....................................I.............. .......... ..........I--................... ........................................................................................- .............. ................-............. ............... ........... Winter Outdoor 320F ..........I---------------.................... ............I..............1---.1------- Winter Indoor 70OF ..................... ........... .................. ............................................. ....................................................... .................................................. Sensible Cooling 18,813 Btuh ............ .................................-.................... .................----......................---............. Latent Cooling 2,592 Btuh .................................... .................................................................................- ......................................... .................................................................-..............­............................... Required Cooling Airflow 855 CF!vI ........... ...........- Sensible Heating 20,318,Btuh ......................... ----------------- ............................. ................... Required Heaing Airflow 264 CFM ................-------------- ------------- ........... ...................-.-............. All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree