Loading...
1085 Atlantic Blvd HVAC 2012 Unit 13-22 Application Number . . . . . 12-00001633 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 13 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 .TOB ADDRESS: A?`[: -vi t ,qtr &agL ERMIT# PROJECT VALUE $ ARI# 14 7 d©O 2--7 REQUIRED i NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit j Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit ,Z %1z- Heat: Unit Quantity_I BTU's Per Unit S K tJ Seer Rating ( 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority toviolatethe provisions of any otherstateor local law regulation construction or the performance of construction. Property Owners Name LZ Phone Number Mechanical Company AuA P 4*r—Ocm JfPhonZ63-$$(- F lo3?1`T-9?D; Co. Address: 4ZZ'X, /7.,%, eJ -Rr-r3e4 City LgkgI & State F*/ Zip n License Holder(Print): _ t.1 nn State Ce ' t ation/Registration #dkb 54//60 Notarize D_ RAHAMANDAWHITE MY COMMIZON#EE 057 ✓ day EXPIRES;May 21,201�w and sub Bribed before his O f 20 Bonded Thru Notary Public Underwriters tore of Notary Public ANNOILICERTIFIE T. www.ahridi rectory.or g 'A certificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at.vww.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied:disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ILA10' The information for the model cited on this certificate can be verified at..ti . .ar,r, :r• ,;'J, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on P%. .■ ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 3 DesignStar Load Calculation Results are intended for use with Rheem heating and cooling systems only ?i4 New Location: Street Address 1063 Atlantic blvd, DUVAL, FL 32233 Latitude, Longitude 30.3375°, -81.76860 House Square Footage: 950 sq. ft. _.. ..__.. .. .. ... ......__.._ ... ....._ Name: Terry Runnels Phone: 863-581-4268 _............ ....................... ..... Email: terunsr@aol.com _.... ..__._.._ .... Housei • SHR .75 .. ......._. _...... .. ...___. __ _....__ .......... Number of residents 4 Ceiling height 8 .._... Wall U-value R-value 0.091 11 Floor U-value R-value 0.2 15 Ceiling U-value ( R-value 0.05 ( 19 Window U-value 1 Window SHGF 0.85 Moisture grains 0.85 Duct loss % 10 Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 .. .... ... .._. . .. ..... . . Summer ventilation 0 i,,,siqa Conditions, OutdoorHeating Cooling ............ ----------- Dry bulb ('F) 32 93 ................... ...... Daily range M --.-................... ............... ................. ................... Relative humidity 50% ............ ............. Moisture difference 53 ................... ............. .... ................__............. . Indoor Heating Cooling ................................................ ........... ..........--------------- ............. ............................ Indoor temperature ("F) 70 75 ............. -.............. Design temperature differenceff) 38 18 ................. .......... - ............................................ Reatlhq, Loads, Area Btuh % of load Wall 2093 9 . Floor 7220 30.9 ............1.1-1-- --...... Ceiling 1913 8.2 .......... Windows 6080 26 .......... ............. Infiltration 3939 16.9 ..... ... ... System Efficiency Loss 2125 9.1 Total: 23370 ................. Heating Loads 23,370 BrU.Ilir Ceiling Wall Floor System Efficiency Infiltration Windows Area Btuh % of load ................ .. ............ Wall 992 4 Ceiling 906 3.6 Windows 15150 60.5 Sensible Infiltration 1399 5.6 Latent Infiltration 2547 10.2 System Efficiency Gain 20919 3.4 Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 Total: 25034 Sensible load 22050 ....._.I.......... ......._... Latent load 2984 SHR 0.88 Capacity at .75 SHR 2.45 Tons Cool i ng Loads 25,034 BTU/hr Sensible People Load — Latent People Load r — - Ceiling -_---- Wall Internal Sensible Infiltration -System Efficienc, Windows \ Latent Infiltration AED Graph 30000 20000 S 10000 0 8am 9am loam llam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm - - — ----- I,-,—Hourly Loads —Average ) ACCA Manual System equipment selection will be made using the following Manual S derived values. Summer Outdoor 93°F Summer Wet Bulb 77°F Summer Indoor 75°F Summer Design Grains 50% Winter Outdoor 32°F Winter Indoor 70°F Sensible Cooling 22,050 Btuh Latent Cooling 2,984 Btuh _ .... ._ ...................._... Required Cooling Airflow 1,002 CFM Sensible Heating 23,370 Btuh Required Heaing Airflow 304 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local. state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree Application Number . . . . . 12-00001632 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 14 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 A MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-58,26 Fax (/9�04�) 2447-5845 .TOB ADDRESS: �0 � '�LcL� �c, i/4 f �!l/�L�ERMIT# PROJECT VALUE $ ARI# 1-4 7 Q0 Z-7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit �� Heat: Unit Quantity�_ BTU's Per Unit SS K LJ Seer Rating ( 3 Duct Systems: Total CFM TT REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.1 hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any'other state or local law regulation construction or the performance of construction. Property Owners Name A 12 fumes hf-h-r, ,� Phone Number � Mechanical Company rt Yt ir" t'�ica � rt t nice Phone�a�$��- Fax to3 779-47r�; Co. Address: 4Z 'A, (,ivLcLe I 7RC=4A City Ink State EL Zip Q License Holder(Print): — u nrt State ification/Registration #(14-(!p 40/60 Notarized Signature of License Hold Sworn ands scribed before this day of 201 Qtr o•,, f AMANDA WHIM Signature of Notary Public My I COMMISSION#EE 057348 BaWe XPI N S. May 21 2015 Wary Pub. Ur rters CERTIFIEDTM www.ahridirectory.org certificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D" Indoor Unit Model Number: AR'F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. •assw� � DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on A. .■ '-' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 Desig nStar Load Calculation Results are intended for use with Rheem heating and cooling systems only Tnc New Dogma o!Com'ort'' Location: Street Address 1088 Atlantic blvd, DUVAL, FL 32233 Latitude, Longitude 30.3375°, -81.76860 House Square Footage: 950 sq. ft. Name: Terry Runnels Phone: 863-581-4268 _.................._............... _... __.... Email: terunsr@aol.com ....___._._._. _ _..._._. iHoormation SHR •75 _.__._... . ..._... . .... .... .. __ ._ ..- _........ __..... ........ Number of residents 4 Ceiling height 8 _ -_ . ..__._ ........_._ .._ ._ . .._..... ... .... _ _ ....._..........._ Wall U-valuer R-value 0.091 11 Floor U-value R-value 0.2 15 Ceiling U-value R-value 0.05 ( 19 Window U-value 1 Window SHGF 0.85 Moisture grains 0.85 Duct loss % 10 Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 ._._...___...._-.- Winter ventilation 0 Summer ventilation 0 LpesAin Conditions Outdoor Heating Cooling Dry bulb ('F) 32 93 .................... .......... Daily range M ---l-...................................................................... ..................... ...... Relative humidity 50% ................ ...... Moisture difference 53 ............... .................. IndoorHeating Cooling .................... ....... Indoor temperature (OF) 70 75 ........... Design temperature difference('F) 33 18 ............................................ �Heating Load Area Btuh % of load Wall 2093 9 Floor 7220 30.9 _........... ... . Ceiling 1913 8.2 Windows 6080 26 Infiltration 3939 16.9 _ ......_. System Efficiency Loss 2125 9.1 Total: 23370 ............. _ . ...__..... ..___.__ . Heating Loads 23,370 BTU/hr r Ceiling Wall Floor System Efficiency Infiltration Windows J ' Coolinq Loads Area Btuh % of load Wall 992 4 Ceiling 906 3.6 Windows 15150 60.5 Sensible Infiltration 1399 5.6 Latent Infiltration 2547 10.2 System Efficiency Gain 2099 8.4 Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 Total: 25034 Sensible load 22050 Latent load 2984 SHR 0.88 Capacity at .75 SFR 2.45 Tons Cooling Loads 25,034 BTU/hr r Sensible People Load �---r Latent People Load Ceiling --Wall Internal ry �Sensible Infiltration System Efficiency Windows \ Latent Infiltration AED Graph 30000 20000 9 R 0 J 10000 0 Sam 9am 10am Ilam 12pm fpm 2pm Spm 4pm Spm 6pm 7pm Bpm Hourly Loads —Average A 1 System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F Summer Wet Bulb 77°F ....... Summer Indoor 75°F Summer Design Grains 50% Winter Outdoor 320F Winter Indoor 70°F Sensible Cooling 22,050 Btuh Latent Cooling 2,984 Btuh .._ ....... ..... . - ........_..... ..... .... .. ... . ......... _ Required Cooling Airflow 1,002 CFM Sensible Heating 23,370 Btuh ........__...... .... .._ ..._ ......._...... . .... ...... .. ......... _ ....__._ Required Heaing Airflow 304 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD = ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001634 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 15 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 99 / Ph(904) 247-58126 Fax (904) 247-5845 JOB ADDRESS: /045 A T' ,'a-n t r�c- -5(, y4 • # PROJECT VALUE $ 71Z -7 2 , 5 l ARI# 147 DOO 2--7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit .2 '/z- Heat: Unit Quantity IBTU's Per Unit S K LJ Seer Rating ( 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority toviolatethe provisions of any'otherstateor local law regulation construction or the performance of construction. Property Owners Name X r/o —6a,-- Phone Number Mechanical Company � iI ' t'fio i1 t� glee Phonte65-$$1- Fax !-3 779 u -97y; Co. Address: 4 ZZZ. 1 City laleglAg State EL Zip stn License Holder (Print): _ pot I nn State rtification/Registration #CJS{!o 44/60 Notarized Signature of License Holde42Z�-- C 1EM AMgWpgYVHITE Sworn an bscribed before t day of20SSION b EE 057349S:May 21,2015 Signature of Notary Publictary Public Underwriters Ag" REISS CERTIFIEDTM www.ahridirectory.org 'A Certificate of Product R AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR'F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the e unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirecto 0 g TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The infornation for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"'verify Certificate"link and enter the AHRI Certified Reference Number and the data on jWU BE ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 r Desi nstar Load Calculation Results are intended for use with Rheem heating and cooling systems only Tnc New Ocgioo of Cw'or*" 'Customer • . • Location: Street Address 1088 Atlantic blvd, DUVAL, FL 32233 Latitude, Longitude 30.3375°, -81.76860 House Square Footage: 950 sq. ft. Name: Terry Runnels Phone: 863-581-4268 Email: terunsr@aol.com House • • SHR •75 .... _.... ._.... __ ......... ................. Number of residents 4 Ceiling height 8 Wall U-value R-value 0.091 11 Floor U-value R-value 0.2 15 Ceiling U-value I R-value 0.05 1 19 Window U-value 1 Window SHGF 0.85 Moisture grains 0.85 Duct loss % 10 . ..................... . ........ . Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 Summer ventilation 0 lr,, eslqrV,Cond iti ons Outdoor Heating Cooling ............. Dry bulb ('F) 32 93 .......... Daily range M .............. -----------................................... ......................... ............. ...................... ........ Relative humidity 50% ............. ............. ............. .......... ........ Moisture difference 53 ....................... ..........................I...................................................................... .....................--.-............................. Indoor Heating Cooling— ..._..._.._.... . . .. .......................... ................. Indoor temperature ( )F) 70 75 Design temperature differenceff) 38 18 ........................- ................ .................. .................................. ',Heating Load AreaBtuh % f load .............. ............. ............. Wall 2093 9 ............... Floor 7220 30.9 ................ Ceiling 1913 8.2 Windows 6080 26 ..........-.- .1,............... ------- ......................... ...... Infiltration 3939 16.9 ................ System Efficiency Loss 2125 9.1 ........... Total: 23370 ................. .......I.I.-.-�............ ............. Heating Loads 23.370 BTU/hr Ceiling Wall Floor System Efficiency Infiltration Windows k-oolihq Loads- Area Btuh % of load Wall 992 4 Ceiling 906 3.6 Windows 15150 60.5 Sensible Infiltration 1399 5.6 Latent Infiltration 2547 10.2 System Efficiency Gain 2099 8.4 Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 Total: 25034 Sensible load 22050 _............._.._.........._....._...._......_......_.____...__....._. _..._..__...._.........--...._.._._...._..._.._ Latent load 2984 SHR 0.88 Capacity at .75 SHR 2.45 Tons Cooling Loads 25,034 BTU/Iv r Sensible People Load I Latent People Load �---Ceiling /---Wall �-Internal Sensible Infiltration .4 'v g� c System Efficient Windows \ Latent Infiltration 0 16-1 AED Graph 30000 20000 a s 10000 0 Sam 9am loam llam 12pm 1pm 2pm Spm 4pm 5pm 6pm 7pm 8pm (—Hourly Loads —Average__ 1 System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F ...1..._.....-._.............. Summer Wet Bulb 770F Summer Indoor 750F __--------......... _ Summer Design Grains 50% 1111..._1111................................. Winter Outdoor 32°F _.. __..-_ _...................... _. Winter Indoor 70°F Sensible Cooling 22,050 Btuh Latent Cooling 2,984 Btuh _......._..........................1_.....................1..................................... ....................1 .1. .... .. ....... ................ .... .._ - Required Cooling Airflow 1,002 CFM -.._..__.._........................._._. Sensible Heating 23,370 Btuh -1. _1._11__1....................._ . Required Heaing Airflow 304 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree CITY OF ATLANTIC BEACH s1 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001635 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 16 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION #/P 7-1 CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 I 3Z RM JOB ADDRESS: /O � ft Letvl t tit- -5( Vd • ti�fX alb!,// PROJECT VALUE $ 7,Z 7Z • 5 ARI# 7 Q0 2--7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity�_ Tons Per Unit I Z- Heat: Unit Quantity�_ BTU's Per Unit S K tf Seer Rating ( 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name X Zn I:t-& - " oc �ff-�-r� ,,��'� Phone Number _ Mechanical Company n i t^' �T io Al ice Phonc%3-$$r _ i ax ! ?1`T'97r�, Co. Address: 47,"� iZ. �i v� City a tel:.n State FL Zip MIn License Holder(Print): State e ification/Registration #n.*C'O q'// (00 Notarized Signature of License Hold s iM"' pEBORiWgMANDAWHR'E Sworn and scribed before t ay of ?» MY COMMISSION 0 EE 057349 '•.• o`` EXPIRES:May 21,2015 Signature of Notary Public Bonded Th,Notary Public Urn mwi(ers 1: www.ahridirectory.org Certificate of Product Ratings_ AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the e unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www ahridirecto 0 9 TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION 04 KA131 Air-Conditioning,Heating, The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on city Cernificate"link and enter the AHRI Certified Reference Number and the date on AM ,E 'I and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 DesignStar Load Calculation Results are intended for use with Rheem heating and cooling systems only TIC Now aegrao o'oww or— 3 � � • • .S - Location: Street Address 1088 Atlantic blvd, DUVAL, FL 32233 Latitude, Longitude 30.3375°, -81.76860 House Square Footage: 950 sq. ft. Name: Terry Runnels Phone: 863-581-4268 Email: terunsr@aol.com House • . • SHR .75 _._........__._.__..........__...._...._.._.... ......._._....._... ............ _.._.-__...._.__....._....__......-.... . Number of residents 4 Ceiling height 8 _... ... ....... .. . ............ Wall U-value R-value 0.091 11 Floor U-value R-value 0.2 15 _...... _..._._.._......._....._...................._ Ceiling U-value ( R-value 0.05 ( 19 Window U-value 1 _._.__...---.__......._....-._..._._...__._..___ _ . Window SHGF 0.85 ................ Moisture grains 0.85 Duct loss % 10 . ............................ ... . ... Duct gain % 10 Cooling infiltraction (ACH) 0.6 ............ ........................... Heating infiltration (ACH) 0.8 Winter ventilation 0 Summer ventilation 0 Design Conditions outdoor Heating ..._...__.__._Cooling ___.._........._._......._....._.__..____ _ Dry bulb (°F) 32 93 Daily range M ---...................._........._.... ......... --l-,....... . Relative humidity 50% _ .. Moisture difference 53 ___.. . .... ......._....... ....._..... . ... ...................... Indoor _.._Heating_._._. ..Coolin ...... _..._.._............._..-..._.....__.__...........___.._.___._._.._._..____ Indoor temperature (°F) 70 75 Design temperature difference(°F) 38 18 ..... .__...... _.._. • ;lHeatingLoad Area Btuh % ofload ........... Wall 2093 9 Floor 7220 30.9 .................. Ceiling 1913 8.2 Windows 6080 26 -1-....-............... Infiltration 3939 16.9 System Efficiency Loss 2125 9.1 .............. Total: 23370 ...................... .............. Heating Loads 23,370 BTU/hr Ceiling Wall Floor System Efficiency Infiltration Windows Area Btuh % of load Wall 992 4 Ceiling 906 3.6 Windows 15150 60.5 Sensible Infiltration 1399 5.6 Latent Infiltration 2547 10.2 System Efficiency Gain 2099 8.4 Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 Total: 25034 __...._ ..........._.._ Sensible load 22050 Latent load 2984 SHR 0.88 .... .._.._..._ _ Capacity at .75 SHR 2.45 Tons Cooling Loads 25,034 BTU/h, Sensible People Load Latent People Load �— Ceiling -- Wall Internal Sensible Infiltration '.r -- System Efficiency Windows \ Latent Infiltration AED Graph 30000 20000 rs O J 10000 0 8am 9am loam Ilam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm Bpm Hourly Loads —Average System equipment selection will be made using the following Manual S derived values. Summer Outdoor 93°F --.1-1...........-.1 -.1 Summer Wet Bulb 770F ......11.11 1111 _ 1111... Summer Indoor 75°F Summer Design Grains 50% Winter Outdoor 32°F Winter Indoor 70°F . . ............................... Sensible Cooling 22,050 Btuh —.._..-....................11.1..1._.._._.__............. ...... Latent Cooling 2,984 Btuh ............ ........ ....... 1111 .. Required Cooling Airflow 1,002 CFM --... Sensible Heating 23,370 Btuh .... _1111__.. _1111. Required Heaing Airflow 304 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree r� �S f CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . 12-00001636 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 17 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------------------------------------- Application desc 1 CU 1AHU ------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ----------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 ------------------------------------------------------------------ Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 --------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ------ Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. A��T 17 MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 ��,,, I �11 A4bA&L .TOB ADDRESS: /OF.S A�Lqvft'L, I�3, lVA • - :C-PERMIT# PROJECT VALUE $ ?,� - 7 Z - 'l ARI# N 7 DOO Z-7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit Z VZ- Heat: Unit Quantity—I BTU's Per Unit S K Seer Rating ( 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that t have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the ''provisions of any''other state or local law regulation construction or the performance of construction. �� t! Mes Phone Number Property Owners Name Mechanical Company-FU A e'— nice PhonZ65-56-f ax lA3 X7`1-97r� Co. Address: 47,,,.�� -� . City nkaLOL � State EL Zip z CiK License Holder(Print): State C tcation/Registration Notarized Signature of License Holde Et DEB:=h Sworn and su scribed befor this day of 20rMY C� EXSignature of Notary Publi d^ Bonded y 1 CERTIFIEDTM www.ahridirectory.org 'A Certificate of Product RatinaS AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or g e unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirecto 0 TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, � �� Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the data on AM .� -, and Refrigeration Institute which the certificate was Issued,which is listed above,and the Certificate No.,which is listed below. ©2012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 1 � Desi nStar Load Calculation g Results are intended for use with Rheem heating and cooling systems only Teo Now Dc9rce o'Cwn'Or," Location: Street Address 1088 Atlantic blvd, DUVAL, FL 32233 .........._.__..___... ...__..._ _ Latitude, Longitude 30.3375°, -81.76860 House Square Footage: 950 sq. ft. Name: Terry Runnels .... Phone: 863-581-4268 Email: terunsr@aol.com .. HOUSe • • SHR .75 _......__.. ..... _ Number of residents 4 Ceiling height 8 Wall U-valuer R-value 0.091 11 Floor U-value R-value 0.2 15 .................__.._....._.__._....................................................._. Ceiling U-value R-value 0.05 1 19 Window U-value 1 Window SHGF 0.85 . ......... .... ... ............... ...... Moisture grains 0.85 Duct loss % 10 ........._........ .. ......................... ..... ....... ........... Duct gain % 10 Cooling infiltraction (ACH) 0.6 .......................... . ........ ..............._ Heating infiltration (ACH) 0.8 .................................... . Winter ventilation 0 Summer ventilation 0 ,Desiqn Conditlons -._._.. Outdoor Heating _.........___.__..__Cooling Dry bulb (°F) 32 93 Daily range M __..._.........._........... _ Relative humidity 50% Moisture difference 53 .......... ...._............ ........_.............._._............._.............. ....._.... . .._.._.__ _ Indoor Heating Cooling Indoor temperature (°F) 70 75 Design temperature differenceff) 38 18 ,Heatinq Loqds�-, Area Btuh % of load Wall 2093 9 ............ Floor 7220 30.9 .......... 1.1-1-1-.......... Ceiling 1913 8.2 .......... Windows 6080 26 ........... Infiltration 3939 16.9 .......... System Efficiency Loss 2125 9.1 Total: 23370 ............... ........... ............. .......... Heating Loads 23,370 BTU/hr Ceiling Floor Wall System Efficiency Infiltration Windows J Qogling., • Area Btu % of load Wall 992 4 Ceiling 906 3.6 Windows 15150 60.5 Sensible Infiltration 1399 5.6 Latent Infiltration 2547 10.2 System Efficiency Cain 2099 8.4 Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 Total: 25034 Sensible load 22050 Latent load 2984 �.._.__...._._...._._....... -- .._.. _...............................--............._.._. SHR 0.88 Capacity at .75 SHR 2.45 Tons Cooling Loads 25,034 BTU/ht r Sensible People Load + Latent People Load I �--- Ceiling ��--Wall Internal Sensible Infiltration r System Efficient, Windows \ Latent Infiltration r • , U AED Graph 30000 20000 a m s 10000 0 8am 9am 10am 11am 12pm 1pm 2pm Spm 4pm 5pm 6pm 7pm Bpm j —Hourly Loads —Average I CCA Manual S iA System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F Summer Wet Bulb 770F Summer Indoor 750F . _ .._.__ ... Summer Design Grains 50% Winter Outdoor 320F Winter Indoor 70°F Sensible Cooling 22,050 Btuh —.-...............- . Latent Cooling 2,984 Btuh ........................... Required Cooling Airflow 1,002 CFM ."... .. ... _... . ._ .... .............. . Sensible Heating 23,370 Btuh Required Heaing Airflow 304 CFM _. . All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 0art Application Number . . . . . 12-00001637 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 18 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 --------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------- Owner Contractor - ------------------------ ----------------------- 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 --------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ------------------------------------------------- Fee summary Charged Paid Credited ----Due--- ----------------- ---------- ---------- ----- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION j( U( CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax (904) 247-5845 l ,�;J ERMIT# JOB ADDRESS: /OF,S A� ct tet t r�t-- �4 /"�r�e PROJECT VALUE $ �a -7�- 5 ARI# N 7 DSO 2-17 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit Heat: Unit Quantity�_ BTU's Per Unit S K Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate theprovisions of any other state or local law regulation construction or the performance of construction. Property Owners Name�q . 4y eS " Phone Number J Mechanical Company J1 eJ"" to rt ice Phone%3-$g(— ax to3=77`1-97r�' Co. Address: Z, A, 0,;K City la a g aState F71 Zip License Holder (Print): t�r�T ��Lt rin _ State Ce cation/Registration#� L'A //� Notarized Signature of License Hold Sworn and subscribed before i this S a of 20 Z DEBORMArvarDAYMirrE S nature of Notary Publi MY COMMISSION 0 EE 057349 •, a= EXPIRES:May 21,2015 ij pF F ' Bonded Thru NotaryPublic Underwriters CERTIFIEDW rr Certificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),orry e9 unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at vrnw.ahridirecto 0 TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not.in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATIONAir-Conditioning,Heating, The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on own ®m , and Refrigeration Institute which the certificate was Issued,which is listed above,and the Certificate No.,which is listed below. ©2012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 DesignStar Load Calculation Results are intended for use with Rheem heating and cooling systems only t-ic hew G091".a!C4tn'OR" _. Location: Street Address 1088 Atlantic blvd, DUVAL, FL 32233 Latitude, Longitude 30.33750, -81.76860 House Square Footage: 950 sq. ft. Name: Terry Runnels _....__.......... _ . . _.. ... .._. Phone: 863-581-4268 Email: terunsr@aol.com • • . • SHR .75 Number of residents 4 Ceiling height 8 ..._.. . . Wail U-value J R-value 0.09 J 11 .....__..._... Floor U-value J R-value 0.2 15 -_._.. .... ............. . _. _. Ceiling U-value J R-value 0.05 J 19 Window U-value 1 ...... ...---._.........__.._......_..._._._...__....._........ - Window SHGF 0.85 Moisture grains 0.85 Duct loss % 10 ................. .......... . ............. . .... ........... Duct gain % 10 ._...... _......_ _. Cooling infiltraction (ACH) 0.6 ........ .. ....... ......_........... ..... .... ............................ .. . ... ......... ... Heating infiltration (ACH) 0.8 Winter ventilation 0 Summer ventilation 0 , � outdoor Heating Cooling Daily range M Relative humidity50% -- - --� --__----_-_� . _.. I--__ -_--.--_-'__- Moisture difference 53 -_- _--.. _.________________.____ _U�����________________ nnwm Indoor temperature ("F) 70 75 ..........����������� ������ Design temperature difference("F) 38 18 ___ -___-____----'-_-____�______-_'____�..... ;Heatinq� Loa d_s Area Btuh % of load Wall 2093 9 Floor 7220 30.9 .................. ........ Ceiling 1913 8.2 Windows 6080 26 .............. Infiltration 3939 16.9 ............. System Efficiency Loss 2125 9.1 .................. Total: 23370 .....................---......... Heating Loads 23,370 BTU/hr Ceiling Wall Floor System Efficiency Infiltration Windows i ,Coolin • • • • Area Btuh % of load Wall 992 4 Ceiling 906 3.6 Windows 15150 60.5 Sensible infiltration 1399 5.6 Latent Infiltration 2547 10.2 System Efficiency Gain 2099 8.4 Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 Total: 25034 Sensible load 22050 Latent load 2984 SHR 0.88 Capacity at .75 SHR 2.45 Tons Cool i ng Loads 25,034 BTU/lir Sensible People Load Latent People Load �--Ceiling —Wall ,.A�—Internal Sensible Infiltration - „ System Efficienc, Windows Latent Infiltration AED Graph 30000 20000 M R O J 10000 0 8am 9am loam Ilam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm i —Hourly Loads —Average j A 1 Manual S System equipment selection will be made using the following Manual S derived values. Summer Outdoor 93°F _.... ..........__......................_. ---....-_.........._....__. Summer Wet Bulb 770F 0F Summer Indoor 75 - .................._...._.. .... . ............_......._.........._ Summer Design Grains 50% Winter Outdoor 320F -.. _. _._ _._.. Winter Indoor 70°F Sensible Cooling 22,050 Btuh .. Latent Cooling 2,984 Btuh .............-.................-. ...__...._._..................__. ...__......................................................... Required Cooling Airflow 1,002 CFM ............. .._....._..._.._.......__......................_......_......_..... Sensible Heating 23,370 Btuh ._ .... ..........__._.. ........... ...... . Required Heaing Airflow 304 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local. state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . 12-00001638 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 19 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------------------------- Application desc 1 CU 1 AHU ------------------------------------------------------------ Owner Contractor - ------------------------ ----------------------- 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ----------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 ---------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 -------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. w c� MECHANICAL PERMIT APPLICATION gt4tl`7^� / CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax ( 904) 247-5845 .TOB ADDRESS: _,,102t6 ft�LCLvt fisc- �� t/� 1" ERMIT# PROJECT VALUE$ / ARI# N 7 DOO Z-7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit ?, % z-r Heat: Unit Quantity I - BTU's Per Unit 5 K LJ Seer Rating 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name t_/o6�- tt'�rneS M-h-t_� Phone Number Mechanical Company uA ir' t'�io it � Bffice PhontF65-5 Fax !�3 779-9"Ty' Co. Address: 47,7'2. �i K c4 cJ City n� f .� State Zip rc� License Holder(Print): _ un/tState Certificatio egistration #(!Af.p 4l4//6Q Notarized Signature of License Holde :w DEBORAH AMANDA WHITE worn and sub ribed before t day of 2Q(�--- r4°'... r MYcOMMISSIQNItEE057349 i ture of Notary Public na ; :P= EXPIRES:May 21,2015 g y Bonded 7hru Notary Public Underwriters www.ahtidirectory.org 'A Certificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressty disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at. .w.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI,This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual.personal and confidential reference. CERTIFICATE VERIFICATION ®' The information for the model cited on this certificate can be venfied at www.ahridirectory.org, JA Air-Conditioning,Heating, click on"Verify Certifica'e"link and enter the AHRI Certified Reference Number and the date on ow an -! and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 02012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 , .. Desig nStar Load Calculation Results are intended for use with Rheem heating and cooling systems only T94 NOW C4nr.^r gyp•�nrr'pr!,., Location: Street Address 1088 Atlantic blvd, DUVAL, FL 32233 ........ . ... . ._...................._ . __- __ _...._ . ..__.__..._._.... Latitude, Longitude 30.3375°, -81.76860 House Square Footage: 950 sq. ft. Name: Terry Runnels Phone: 863-581-4268 Email: terunsr@aol.com House • . • SHR .75 ......._ ............. ...... Number of residents 4 Ceiling height 8 Wall U-value R-value 0.091 11 Floor U-value R-value 0.2 15 ...... . Ceiling U-value R-value 0.05 1 19 Window U-value 1 Window SHGF 0.85 Moisture grains 0.85 Duct loss % 10 ...... .... ...... .................... .... . .... ................. .. ..................... .. . Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 ........ ... . .... ....... . .... ..... ... .... .. ................. .. . .... Summer ventilation 0 �Desiqn Conditions Outdoor Heating Cooling ..................... ............... ...... ------- Dry bulb (OF) 32 93 ...............I..................... Daily range M ...........--.................................................. .......... ............... ............. .......... Relative humidity 50% .......... Moisture difference 53 ................................................................ ................. ............... .......... ................................ ..................................................................................................... Indoor Heating Cooling ............-........... .......... Indoor temperature (OF) 70 75 Design temperature difference(OF) 38 18 ............ .......... Reatinq Loads, Area Btuh % of load Wall 2093 9 Floor 7220 30.9 ............. .............. .......... Ceiling 1913 8.2 ............. Windows 6080 26 .............. .......... .......... Infiltration 3939 16.9 I..,...........-.1 -I.....-............. System Efficiency Loss 2125 9.1 Total: 23370 ............ ................11-........................ .......... Heating Loads 23,370 BTU/hr Ceiling Floor Wall System Efficiency Infiltration Windows Coolinq Load ,,,,. Area Btuh % of load Wall 992 4 Ceiling 906 3.6 Windows 15150 60.5 Sensible Infiltration 1399 5.6 Latent Infiltration 2547 10.2 System Efficiency Gain 2099 6,4 Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 Total: 25034 Sensible load 22050 Latent load 2984 SHR 0.88 Capacity at .75 SHR 2.45 Tons Cool i ng Loads 25,034 BTU!hr Sensible People Load Latent People Load I� -- Ceiling -- Wall Internal Sensible Infiltration System Efficiency Windows� \ `Latent Infiltration t AED Graph 30000 20000 s a s 10000 0 8am 9am loam 11am 12pm fpm 2pm 3pm 4pm 5pm 6pm 7pm Spm ( —Hourly Loads —Average System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F _.....__.__...__..._.__............._._....__...__._..._...._...._........................................_..........._----------.............._.....__._.._._.__....._..._.......... Summer Wet Bulb 770F Summer Indoor 750F Summer Design Grains 50% Winter Outdoor 32°F Winter Indoor 70°F Sensible Cooling 22,050 Btuh Latent Cooling 2,984 Btuh . ... . _.. ._ .. .... ....... Required Cooling Airflow 1,002 CFM ................ . . Sensible Heating 23,370 Btuh .............. - ..._.._ _ _ ._..__. __...._ ._....._ __...... Required Heaing Airflow 304 CFM _._ ..._..._. ...... All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree s CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD j � ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . 12-00001639 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 20 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------- Application desc 1 CU 1 AHU --------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ----------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 ----------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- --- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 4r�ao MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-58126 Fax (//9��04��) 247-5845 JOB JOB ADDRESS: f0 � ft'f`LQ,►-t I r��- 3l ✓4 • fJlZlll/ ERMIT# PROJECT VALUE $ W, 2 7 Z , 5/ ARI# 147 DOO 2-17 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity_I Tons Per Unit .2_ '/y Heat: Unit Quantity I BTU's Per Unit S K LJ Seer Rating ( 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that 1 have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name X 1/o�16L- Ames N-h-�� ,�,''r� Phone Number Mechanical Company rl ir" ''�io rt l nice Phonal-$g/- Fax tP3 77`1-97y' Co. Address: 47,ZA. 0-,;kt Q 7Rc=j City a 1&of StateF/ Zip---125Vn License Holder (Print): _ nrt to Certitic Registration #Cl¢>rp 41/� Notarized Si,-nature of License Holder Sworn and subs ed befor i ay of �0% Signature of Notary Publi CERTI F , r Certificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the products)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,In any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at+rww ahridirector, y, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on own .� and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed bebvK ©2012 Air-Conditioning,Heating, and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 Desi9 nStar Load Calculation Results are intended for use with Rheem heating and cooling systems only Tac New Degree of Com'Ort- • • - • Location: Street Address 1088 Atlantic blvd, DUVAL, FL 32233 Latitude, Longitude 30.3375°, -81.76860 House Square Footage: 950 sq. ft. _.. .._.........._...... _._ _.___ ....... Name: Terry Runnels Phone: 863-581-4268 Email: terunsr@aol.com ,House • . • SHR •75 Number of residents 4 Ceiling height 8 Wall U-value R-value 0.091 11 Floor U-value I R-value 0.2 15 Ceiling U-value ( R-value 0.05 1 19 Window U-value 1 Window SHGF 0.85 Moisture grains 0.85 Duct loss % 10 ... ....... ................._................. ... Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 .. .... . .... ... ... . . ... Summer ventilation 0 Desiqry Conditions Outdoor Heating Cooling .................. ............... .......... Dry bulb ('F) 32 93 .................... Daily range M 11................ ------ ................ .......... .................... ...................... ......................... Relative humidity 50% Moisture difference 53 .......... ...........I.........................I.......... .......... indoor Heating Cooling .................................................... ----------------- .................................... indoor temperature ("F) 70 75 Design temperature differenceff) 38 18 ............ ................... WOW I ,Heating: Loads. Area Btuh % of load .................... .............. ........ Wall 2093 9 Floor 7220 30.9 -..1.--.-.'.1................... ............ ............ Ceiling 1913 8.2 Windows 6080 26 ................ .............- .............. Infiltration 3939 16.9 1-1-..............-1-1...... ................... 1- .1.11 -.1. System Efficiency Loss 2125 9.1 -1-1-1-1--............ .............. Total: 23370 ................. .............. .......................... Heating Loads 23,370 BTU/hr Ceiling Wall Floor �W System Efficiency 1001, Infiltration Windows Cooling • • • Area Btuh % of load Wall 992 4 Ceiling 906 3.6 Windows 15150 60.5 Sensible Infiltration 1399 5.6 Latent Infiltration 2547 10.2 S;rstern Efficiency Gain 2099 8.4 Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 Total: 25034 Sensible load 22050 Latent load 2984 SHR 0.88 Capacity at .75 SHR 2.45 Tons Cooling Loads 25,034 BTU/hr Sensible People Load Latent People Load I Ceiling /--Wall Internal Sensible Infiltration System Efricienc, Windows \ Latent Infiltration T • - •U - i • s AED Graph 30000 20000 a m 0 J 10000 0 Sam gam loam llam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm 8pm —Hourly Loads —Average ,ACC1 System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F Summer Wet Bulb 77°F _. . _.. . __ .._..... .... Summer Indoor 750F Summer Design Grains 50% Winter Outdoor 32°F Winter Indoor 70°F Sensible Cooling 22,050 Btuh Latent Cooling 2,984 Btuh Required Cooling Airflow 1,002 CFM Sensible Heating 23,370 Btuh __. . _ ...... __ ___.. __ . ......__..... Required Heaing Airflow 304 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree 'UX CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001640 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 21 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 ----------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ------------------------- Fee summary Charged Paid Credited Due ----------------- --------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ' MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 / � Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: ZO2 5 T L'CLI i ! r'C- —y( ✓4 ERMIT# PROJECT VALUE $ 7,j27;2- , t/ ARI# 14 -7 pp p 2.17 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity�_ Tons Per Unit .2_ %Iz- Heat: Unit Quantity�_ BTU's Per Unit S K LJ Seer Rating ( 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the/provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Q IZE6:f ., M `` Phone Number Mechanical Company llrt K tr" ro rt tce Phon 3- axt�?7`l-9"TD; Co. Address: 4 Z-Z-A. (,i vt 1 Lj City�e�R State�Zip Q License Holder (Print): _ Luirt State Cert ation/Registration N14-r-0 41/60 Notarized Signature of License Holde -.P; orn ands ribed before , J thisday of 20� DBORAH AMANDA mirrE 4 MY COMMISSION SEE057349 nature of Notary Publi EXPIRES:May 21,2015 y p f 1y4t` Balled Thru Notary Pubric Underwriters Certificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an astensk O indicate a voluntary rerate of previously published data.unless accompanied with a WAS.which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the products)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at riww.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,In any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ®' The information for the model cited on this certificate can be venfied at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on ON ,! and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which Is listed below. 92012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 Desig nStar Load Calculation Results are intended for use with Rheem heating and cooling systems only Tno Now Location: Street Address 1088 Atlantic blvd, DUVAL, FL 32233 Latitude, Longitude 30.33750, -81.76860 House Square Footage: 950 sq. ft. Name: Terry Runnels .......... ....... ........... ......I.......... _....... Phone: 863-581-4268 Email: terunsr@aol.com Information SHR •75 ............... ... ............_.. ._ ..............._....... ..__................................... . Number of residents 4 Ceiling height 8 Wall U-value R-value 0.091 11 Floor U-value R-value 0.2 ( 5 Ceiling U-value R-value 0.05 19 Window U-value 1 Window SHGF 0.85 Moisture grains 0.85 Duct loss % 10 Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 Summer ventilation 0 V :Desiqn, Con • • Outdoor Heating Cooling Dry bulb (°F) 32 93 .__............ .................... ......................._......._ ......._..... _ __................. _. Daily range M Relative humidity 50% _ _ _ _. ...__..... ............ Moisture difference 53 ........_. .. . ............_ . ._. . .................... _......... ...._..__...................................... .._.... ........ ........_.. ...._. ........ Indoor Heating Cooling Indoor temperature (°F) 70 75 Design temperature differenceff) 38 18 ....... __. .. _._ ... __....... .. .. ......... h HeatiMLoad Area Btuh % of load Wall 2093 9 Floor 7220 30.9 ........... Ceiling 1913 8.2 .......... Windows 6080 26 infiltration 3939 16.9 System Efficiency Loss 2125 9.1 Total: 23370 ................... Heating Loads 23,370 BTU/hr Ceiling Wall Floor System Efficiency Infiltration Windows J Me 11 - Area Btuh % of load Wall 992 4 Ceiling 906 3.6 Windows 15150 60.5 Sensible Infiltration 1399 5.6 Latent Infiltration 2547 10.2 System Efficiency Gain 20919 3.4 Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 Total: 25034 Sensible load 22050 Latent load 2984 ....... _..._ SHR 0.88 Capacity at .75 SHR 2.45 Tons Cool i ng Loads 25,034 BTU/hr r Sensible People Load I — Latent People Load Ceiling -- Wall - Internal �-Sensible Infiltration System Efficienc,. Windows�� \ Latent Infiltration S 115139 to FROM M 0 s y, AED Graph 30000 20000 a R 0 J 10000 0 8am 9am 10am 11am 12pm fpm 2pm Spm 4pm 5pm 6pm 7pm Spm Hourly Loads —Average I 1 1 Manual S, System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F Summer Wet Bulb 77°F Summer Indoor 75°F Summer Design Grains 50% Winter Outdoor 32°F Winter Indoor 70°F Sensible Cooling 22,050 Btuh Latent Cooling 2,984 Btuh .......... . ........ .. . ........._ ........ ..... ..... . ...._..._ ..... ...... ..... Required Cooling Airflow 1,002 CFM Sensible Heating 23,370 Btuh Required Heaing Airflow 304 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD J = ATLANTIC BEACH, FL 32233 :r- INSPECTION PHONE LINE 247-5814 Jilt Application Number . . . . . 12-00001641 Date 11/06/12 Property Address . . . . . . 1085 ATLANTIC BLVD 22 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 5/05/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (-904) 247-58) &dZEL 26 Fax (904) 247-5845 JOBADDRESS: /Oa5 A� -lco-t l rlt- -5( V4 • ERMIT# PROJECTVALUE $ & 272, 12 ARI# N7DeOnZ-7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity�_ Tons Per Unit Heat: Unit Quantity_ I BTU's Per Unit S K Seer Rating [ 3 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the /provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 12 ff ,,�'� Phone Number Mechanical Company Llrl t/"' ItTioy it �l ffice Phon o3-$$/— PZax4-3 77%27,); Co. Address: 4Z 'R. (moi Pt e! City State F71 Zip—:i�tn License Holder (Print): _ an rt State Cert' c on/Registration #(!A-eZ 44/60 Notarized Signature of License ,• ""'° �vss °EE057 rn and s cribed befor h' ay _ 2P/�' EXPIRES:May 21,2015 Bonded ThreNotarfPublic Unde T ature of Notary Publ• '\ Ah RAMP rr Certificate of Product Ratings AHRI Certified Reference Number: 4700027 Date: 9/10/2012 Product: Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: GSX130301D* Indoor Unit Model Number: AR*F303016C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 28400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previousty published data,unless accompanied with a WAS.which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)fisted on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ®' The information for the model cited on this certificate can be verified at www.ahridirectory.org, 04 Air-Conditioning,Heating, click on"beefy Certificate"link and enter the AHRI Certified Reference Number and the date on AI ■o III and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. 02012 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 129917767496898595 i Ug1 , . � Desi nStar Load Calculation Results are intended for use with Rheem heating and cooling systems only Yno New Ocgroo o!CWorr'V Location: Street Address 1088 Atlantic blvd, DUVAL, FL 32233 Latitude, Longitude 30.3375°, -81.76860 House Square Footage: 950 sq. ft. .. ..... __..._ _.. _......._. Name: Terry Runnels Phone: 863-581-4268 Email: terunsr@aol.com ...... __...... ___...... House • • SHR .75 .._.._..__................... ..... ....._..... . ... . .... ......... ............. ......... . .................. Number of residents 4 Ceiling height 8 Wall U-value ( R-value 0.091 11 Floor U-value I R-value 0.2 1 5 Ceiling U-value R-value 0.05 1 19 Window U-value 1 Window SHGF 0.85 Moisture grains 0.85 Duct loss % 10 Duct gain 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 Summer ventilation 0 �'Desiqn Conditions Outdoor Heating Cooling Dry bulb (°F) 32 93 ..................._.._......_. __.................... Daily range M Relative humidity 50% .......... Moisture difference 53 .......... .............. ... .._........ .. ..... ....... ... . _.. .... ..._.................. .... .................. Indoor Heating Cooling Indoor temperature (°F) 70 75 ...... . ..:. . ..._. ._..._..... . .. .. ... .... Design temperature differenceff) 38 18 ._ . ..._. __. _... ..... . ......... _ HeatingLoaArea d -...Bt,u,h... of loa-d. Wall 2093 9 .......... Floor 7220 30.9 ............ ........... .................. Ceiling 1913 8.2 Windows 6080 26 ............... Infiltration 3939 16.9 ................ .......... System Efficiency Loss 2125 9.1 Total: 23370 ...................... ............................-.-I........................................ Heating Loads 23,370 BTU/hr Ceiling Wall Floor Sys tern Effic ienc Infiltration Windows t • Area Btuh % of load Wall 992 4 Ceiling 906 3.5 Windows 15150 60.5 Sensible Infiltration 1399 5.6 Latent infiltration 2547 10.2 System Efficiency Gain 2099 3. Internal 1066 4.3 Sensible People Load 437 1.7 Latent People Load 437 1.7 -------- Total: 25034 Sensible load 22050 ........................__ ......_....._..._........_.._..................._.._......_...._............. -..._........--__......... Latent load 2984 ............. _....__:._..........._....... ._._....__._.._ SHR 0.88 .......... _......:__..........................-___._._._..__.....__._.._.........____._._.............._........_:._ Capacity at .75 SHR 2.45 Tons ...................___. _. ....._ Cool i ng Loads 25.034 BTU/hr r Sensible People Load I Latent People Load �--Ceiling /--Wall Internal �-Sensible Infiltration System Efficiency Windows Latent Infiltration AED Graph 30000 20000 a m 0 J 10000 0 8am 9am 10am 11am 12pm 1pm 2pm Spm 4pm 5pm 6pm 7pm 8pm i —Hourly Loads —Average^ CCA Manua[ S System equipment selection will be made using the following Manual S derived values. Summer Outdoor 930F Summer Wet Bulb 770F Summer Indoor 750F Summer Design Grains 50% _ .... - Winter Outdoor 320F Winter Indoor 70°F Sensible Cooling 22,050 Btuh Latent Cooling 2,984 Btuh ....... . . ...... ... Required Cooling Airflow 1,002 CFM .-_..._......_.._.........__ ._ . Sensible Heating 23,370 Btuh .............. Required Heaing Airflow 304 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree