Permit HVAC 1085 Atlantic Blvd 31 2012 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 12-00001844 Date 12/19/12 Property Address . . . . . . 1085 ATLANTIC BLVD 31 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ 1085 ATLANTIC LLC RUNNELS AIR CONDITIONING 5118 N 56TH ST 4222 CINDY RD TAMPA FL 33610 LAKELAND FL 33810 (863) 581-4268 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/17/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOBADDRESS: /04ff 4to-�,tt'e- A9aA&AmbzZ0PERM1T# PROJECTVALUE $ ARI# N 7 000 Z--7 REQUIRED NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratin Duct Systems: Total CFM REQ UIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit 5�K- Seer Rating I Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have re�i this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 9 L�a�� M Phone Number r Mechanical Company AU/1 nje(S k,—&"J." #'OBOicle Phonc%3-5 a x'W453'-7 ,Oki(/!R 61—F Co. Address: 4Z-Z'A, 0-,1'k4Q 2=44 City Lakaj&gj State F71 Zip3nfn L License Holder (Print): —1 %--rrLi E-Ratirtmej,$ j StatwGrtification/Registration#Ck.0 4�1160 Notarized Signature of License Holder-�� Sworn I and szscribed before me this day of 20 Signature of Notary Public At LAW ' www.ahridirectory.org A Certificate of Product Ratings AHRI Certified Reference Number: 4765491 Date: 9/10/2012 Product: Split System:Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: GSX130241C* Indoor Unit Model Number: AR*F182416C* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EIVIERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LID. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representation*,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind&rising out of the use or performance of the product(s),orthe unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRL This Certificate shall only be used for Individual,personal and confidential reference purposes. The contents of this Certificate may not,In whole or In part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,In any form or manner or by any means,except for the user's Individual,personal and confidential reference. CERTIFICATE VERIFICATION The Information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Condifloning.Hoofing, click on"Verify Cartiflcate"link and enter the AHRI Certified Reference Number and the date on no ILI and Refrigeration Institute which the cortiftate was issued,which Is Rated above,and the Certificate No,which Is listed below. 02012 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 129917765623209026 DesignStar Load Calculation Results are intended for use with Rheem heating and cooling systems only Tne Now 009too Of 00WOrt Location: ..................... ................................ .................. ......................... ------ Street Address 1088 Atlantic blvd, DUVAL, 1�1- 32233 ............... ....... ............. Latitude, Longitude 30.3375 01, -81.76860 .............--L................................................... .......... ...................-................... ...... ..................... ......... House Square Footage: 825 sq. ft. .................. .......... ............... ........-..................................... ...................................... ------------------- Name: Terry Runnels ............................. .................................................-,.................. Phone: 863-581-4268 .......... -........... ................................. .................................-- ............. ............... ----------- .......... .............. Email: terunsr@aol.corn ..............- ............. ......... ............... ........................................................-............... ................. "House: lnformatioW" SHR .75 ............. ..................... ...................-------.......--------.............................. ............................ ....... ............. Number of residents 4 ........... ............... ............--..................................- ................. Ceiling height 8 -.1--.................... .........................-....... ........-.-....................... ..........-.................... Wall U-value I R-value 0.09111 I.-I.-..................I I................. L............................ .............- .......... ............................ ........................ .................... ..................... Floor U-value I R-value 0.2 5 .............. ----------- ..........--l-.....---------------...................... ------ ...... Ceiling U-value I R-value 0.05 119 .......................­­­­---........................... ................ .............. .................... ........................................... Window U-value 1 ........................ ................ ............ ........ ------------- Window SHGF 0.85 11-..................1 11.11 -........... ............... ............ ....... 1 1.- -.1-1-1 - 1.11111.1-1 11...... Moisture grains 0.85 .......... ........... ...... -------------- ............ ....... Ductloss % 10 Duct gain 10 .............. ..................... ........... ............... --------------- ....... Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.� .............. Wi nter venti I ati on 0 Summer ventilation 0 Outdoor Heating Cooling ............. ------- Dry bulb (OF) 32 93 1---1-1................ ........................---........................................ ........... ................... ................... ........................ Daily range M ................ ..................------- ............... Relative humidity 50% ...................................................................................... ...............I."........................ ........................... .................... Moisture difference 53 ........... ...................... ........... ............... ............................-................... ........................ .......... ....................... ............ .............. Indoor Heating Cooling ................. .......... ............ ........... ....... .......... Indoor temperature (OF) 70 75 ...........I.. ..........I.......... ............................................. . ....... ..................................... .............. Design temperature difference(OF) 38 18 .............. ........... ..............I............................. .................................. .................. ...............................-................................................................ M.M I Mo M OEM Area Btuh % ofload ------------- Wall 1951 9.6 -.1—...............................-........... .................--............. Floor 6270 30.9 ......I...............-- 1.-.-.-1..-- ..................................... --.-........... Ceiling 1662 8,2 ........... ........... ..................... Windows 5168 25.4 .................... ...........................----........... infiltration 3421 16.8 ..........-11.......... ............................. System Efficiency Loss 1847 9.1 -.1.1.......... ............. Total: 20318 .......... ................................................ .................... Heating Loads 20,318 BTU/hr Ceiling System Efficiency Loss Floor Wall Infiltration Windows J Area Btuh % of load .......... Wa 11 924 4.3 ci-2iling 787 3.7 ' Windows 12739 5 9.7 Sensible infiltration 1215 -5.7 Latent Infiltration 2212 1.0.3 System Efficiency Gain 1793 8.4 Internal 926 4.3 Sensible People Load ........... .......... Latent People Load 318 0 1.8 Tota 1: 21405 ........... Sensible load 18313 .I I I.�-I I�........... Lai-.ent load 2592 SHR 0.88 Capacity at .75 SHR 2.09 'rons Cooling Loads 21,405 BTU/hr Sensible People Load Latent People Load I Ceiling Wall Internal Sensible Infiltration System Efficienc, Windows Latent Infiltration AED Graph 20000 15000 l0000 5000 0 8am 9am loam llarn 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm apm Hourly Loads Ave ra--� ge �ACCA Manua['S�' System equipment selection will be made using the following Manual S derived values. Summer Outdoor 93"F I........... -............... ................... .................. .................................................................. ................. Summer Wet Bulb 770F ...................... ...................... .............-............ ................ Summer Indoor 750F .................. ..................................................-----'L1................................................ ...................... ....... Summer Design Grains 50% ............--1-11-1�................-................... ................. ........... .................. .......... Winter Outdoor 320F ............r.......... ........ ............. .................... ................ ............ .................... Winter Indoor 70OF ............... ............................. .......... ..........- ................. ................... ................... ...................... Sensible Cooling 18,813 Btuh ................. ------------------- .........................-r."-..................­.......................I.-........... .......... ............. Latent Cooling 2,592 btuh .............. .......... .............. .......... .............. ..............................I..........­.......................... .................... Required Cooling Airflow 855 CFM ............................ ------ ................. ..........-1 --1 ---......................11....... Sensible Heating 20,318,Btuh ..................------.—--------------- ............-----------------...........-.................... Required Heaing Airflow 264 CFIVI ........................................... ...................................... .........................-- ---......... .................................. All calculations are based upon approved hvac industry standards and procedures,and comply widi all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree