Loading...
1021 Atlantic Blvd #1001 - HVAC 1'1(1 ' \s„ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-MECH-560 Job Type: MECHANICAL HVAC ONLY Description: HVAC - 1 AC, 1 AHU, 4 TON -UNIT 1001 Estimated Value: $4,400.00 Issue Date: 3/8/2016 Expiration Date: 9/4/2016 PROPERTY ADDRESS: Address: 1021 ATLANTIC BLVD = RE Number: 177602-0040 PROPERTY OWNER: Name: EQUITY ONE ATLANTIC VILLAGE, Address: 16 NE MIAMI GARDENS DR ATTN: TREASURY DEPT GENERAL CONTRACTOR INFORMATION: Name: COOL CHANGE HEATING & AIR Address: 4596 HARBOUR CT QA MANSON L. MCCLAIN, JR Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $32.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $115.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALI. Cr1'Y OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION f 0 ZCITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 CT' Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: 1001ATLANTIC BLVD, ATLANTIC BEACH, FL 32233 PERMIT# PROJECT VALUE $ 4400 ARI# 3015811 REQUIRED Air Handling Equipment Only X Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit Heat: Unit Quantity 1 BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATI u TEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Un t 4 Heat: Unit Quantity BTU's Per • Seer Rating 13 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty — Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Equity One Atlantic Village Inc. Phone Number Mechanical Company Cool Change Heating& Air LLC Office Phone 904-571-1944 Fax 904-928-9261 Co. Address: 4596 Harbour North Ct City Jacksonville State FL Zip 32225 License Holder (Print): Manson L McClain State Certification/Registration # CAC 1816300 Notarized Signature of License Holder � — Before me this day of /)%a 20 ,� LEON WILLIAMS / s. '. Commission#FF 078092 ) R° Expires January 29,20187roy Signature of Notary Public _ "•' �'e p Fn'n Insurance 800.385.7019 .� Right-Suite®Universal 2015 Load Summary Job: Sally Beauty Supply -41- wrightsoft Building DDate: Mr 07,2016 Project Information For: Sally Beauty Supply 1001 Atlantic Blvd, Atlantic Beach, FL 32233 Zone: Building COOLING LOAD 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1700 LDT Inside: 75 °F Outside: 93 °F TD: 18 °F RH: 50 % MoistDift. 52.3 gr/Ib Mult: 1.0 Ins.wb 63 °F Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 1821 - 3. TRANSMISSION GAINS Sensible 10141 - Walls: 5206 - - Glass: 953 - - Doors: 109 - - Partitions: 0 - - Floors: 0 - - Ceilings: 3873 - - 4. INTERNAL HEAT GAIN Sensible Latent 16954 4000 Occupants: 5000 4000 - - Lights: 8610 - - - Motors: 0 - - - Appliances: 3344 0 - - 5. INFILTRATION: Outside air cfm: 10 196 355 6. SUBTOTAL: Space load Sensible Latent 29111 4355 Envelope 29111 4355 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLY DUCT 1456 - 8. SUBTOTAL: Space load +supply duct 30567 - Actual cfm: 1600 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 184 3599 6536 10. RETURN AIR LOAD: Lighting + plenum(net) 0 - 11. RETURN DUCT 873 - 12. TOTAL LOADS ON EQUIPMENT 35039 10892 HEATING LOAD 13. DESIGN CONDITIONS Mutt: 1.0 Inside: 70 °F Outside: 32 °F TD: 38 °F 14. TRANSMISSION LOSSES 15077 Walls: 6503 - Glass: 2326 - Doors: 265 - Partitions: 0 - Floors: 4126 - Ceilings: 1857 - 15. INFILTRATION: Outside air cfm: 90 3778 16. SUBTOTAL: Space load 18855 Envelope 18855 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT: 943 18. VENTILATION: Make-up air cfm: 184 7723 19. HUMIDIFICATION 4889 Piping 0 20. RETURN DUCT 566 21. TOTAL HEATING LOAD ON EQUIPMENT 32976 4 wrightsoft Rig ht-Su rte®Universal 2015 15.0.25 RSU11033 2016-Mar-071P0 age1 9 ...\DocumentstCool ChangetSallys Beauty Supply.rup Calc=CLTD Front Door faces: E I ,aj%LDjjI1 � yA,`1 '-). 1P. 'sf NOTICE OF � _.... ,±;< ADDITIONS or CORRECTIONS �FA< < f,E4C DO NOT REMOVE JOB ADDRESS DATE (0LI krt._,,.► c c SrI OOI 31tct► G THIS JOB HAS NOT BEEN COMPLETED The following additions or corrections shall be made before the job will be accepted. k-k V& L CA 1,4..-.r.ov E,c, 5-rc.4 (.,-- E cQ.)%r► 4...1.L-r-- i s D1/4_3 C..-r-ti--o 4.-Ii- t-e.- tjN.-r \.-C.-T--4 60-(e.--TZ$cD D.J r' . 4 ..........e ` 04 4 rtt C.....hTr C7 o4 ?A J S T- - Ai'c--( \/ri fbC j 5-rdel›.-riv4 ��COM 4E-.WD ?. -C.2'►.t % CX2.4. \-1.-ink 6 5 kl>AV _ l F) ....5--r-- 14 ...3-r-t-&e r `-e.e..-0.-.)ev....<'O . (.As-rt.L.t_. —t L- b i Sol. .." - C'r.( (ZR.5 S%.J P?cY 735 - Z4 ,I. kgv("EL Pc)oF Sv'ZtFike-C-- / - ,r�-g- D`s C---r" `--615 t 5 �..(c•c1> loDE- -- 3O 7.,-f- . Sc 241 - -5- 13 x$55.00 REINSPECT FEE LI NO CHARGE Its is unlawful for any Carpenter, Contractor, Builer or other persons, to cover to cause to be covered, any part of the work with flooring, lath, earth or other material, until the proper inspector has had ample time to approve the installation. After additions or corrections have f BLDG been made contact the Building Dept. ELEC at 247-5814 for an inspection. Office MECH (----- hours hours are Monday through Friday PLMG 8:00 a.m.to 5:00 p.m.