Loading...
1021 ATLANTIC BLVD #977 - SPRINKLER DRAWING —-- ----- ------ - ------------------- ---- i 4 3 2 1 5 6 REMOVE 1rr BRANCH-LINE AND PLUG OUTLET - - ----- � FIRE PROTECTION GENERAL NOTES w . . ,L44 . - wa aw a a 4 1 i � • w 1 1 4 1 2 112 2 — a awww a w 114 I. FIRE PROTECTION SYSTE.M(S) TO COMPLY WITH NEPA 13 (2013) AND ALL APPLICABLE 9-0 15-0 15-0 15-0 1 4"X2" N o 2 112 11-71 2 1 5 15-0 STATE AND I-OCAL_ CODES 0 9--71 2 11-1112 o i C:) 2, ADHERE TO AND OBTAIN ALL PERMITS, LICENSES, AND ALL GOVERNMENT REQUIREMENTS, THRD MECH -4 FINAL INSPECTION AND APPROVAL BY FIRE MARSHAL AND ARCLIITECT/ENGINEER, \� 4, E'UTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH ' - TEE `". 1 A, °'` CD 114 14 1 THE WRITTEN APPROVAL OF THE ARCHITECT — = — 5. PIPE ROUTING SHOWN SHALL 1 1 114 112 112 2 2 2 2 2 x 1—�, 114 ' — BE USED AND ANY ADDITIONAL OFFSETS OR FITTINGS P ' x '., REQUIRED FOR ROPER INSTALLATION COORDINATION WITH OTHER TRADES AND/OR Q_1' Cl- TO MAINTAIN PROPER CLEARANCES SHALL BE PROVIDED. VERIFY EXISTING z Z STRUCTURAL, MECHANICAL, ELECTRICAL INSTALLATIONS AND AVOID ANY/ALL I 13-C OBSTRUCTIONS OR INTERFERENCES WITH FIREROTECTiON PIPE ROUTING :, ;;;.. All moi " i » ��» 6. PIPE SHALL BE REAMED AND CLEANED BEFORE ASSEMBLY, 0 7. METHODS OF HANGING PIPES, HEADERS, AND BRANCHES SHALL BE IN ACCORDANCE WITH NEPA 13, E c ' & PROTECT ALL PENETRATIONS OF SMOKE/FIRE WALLS, CEILINGS, FLOORS, ETC, (SEE DETAIL), r 3 i i-8 ,�. GENERAL_ CONTRACTOR �o PROVIDE ACC=SS PANELS TO Al_._ VALVES ABOVE NON-ACCESSIBLE CEILINGS, a rM 10, AUTI�MATIC SPRINKLER TEMPERATURE RATINGS TO BE IN ACCORDANCE WITH NFPA 13, � t • i 11, COMPONENTS SHALL BE LISTED BY UNDERWRITER'S LABORATORIES (UL) AND/OR _ t{ '� ALL f f APPROVED BY FACTORY MUTUAL CF-M) FOR USE WITH FIRE PROI EC I ION SYSTEMS, _ h. € 12, ALL COMPONENTS SHALL BE LIS-TED ED FOR THE MAXIMUM SYSTEM PRESSURE., 175 PSI MINIMUM, 1 1 1 4 1 2 1 2 2 2 2 2 2 »n::,»,.,:»:,:,:,: ».». _.».» n.:. » » .».. » :.,...... 13, VALVES ON THE FIRE PROTECTION SYSTEM TO BE ELECTRICALLY SUPERVISED. �- - - - - - - - - - - - - - - - - - -�- - - - - - - - - - - - - - - — _ — ._ — - `1" TYPE AND EXACT LOCATION OF FLOW AND SUPERVISORY SWITCHES SHALL ~+• � E E E E I BE COORDINATED BETWEEN THE DIFFERENT RESPONSIBILE TRADES, N EO — J OTHERS 7 SPRINKLER HEAD CO ERAGE TO NOT EXCEED 130sgft E 14, PROVIDE HYDRAULIC DESIGN INFORMATION SIGNS AT EACH SYSTEM RISER, ......: E i F I REPLACE EXISTING PENDENT SPRINKLER HEADS WITH 5..,.,,..: P TED CABINET AS REQUIRED i . S f 16. SCOPE OF WORK: MODIFY 'EXISTINGR KLE E SPRINKLERS SPRINKLER MOUNTED UPRIGHT SPRINKLER HEADS, HEADS TO BE 1 TO 1211 r - EDITION (3013) DUE TO TENANT RENOVATION OPER COVERAGE PER NFPA 1`3 BELLOW THE ROOF D CK IN THE EXPOSED AREA WITH NO f EX STING FIRE PROTECTION SPRINKLER SYSTEM IS A ORDINARY HAZARD GRP II SYSTEM a CEILING o — — — 14 1 1 114 112 2 2 2 //�� 2 2 11 12 , „ 3 r o 1 I i 'Ali FE cV .r i o -- ��, w w44- 1 - 1 114 112 112 2 2 2 2 2 2 2 11 12 11 ------------ ------ DENOTES N DENOTES NEW PIPE 4!4 1` ' [�'_ -------_ ----- -- -- - 1 #0Q•� 'IO 1 �0 �0 1 BIW 10� 1��- 1 r-; ,r -'I w — — — DENOTES EXISTING PIPE TO REMAIN CnTOP Beare Clamp DENOTES FIRE SPRINKLER HEAD TO 0-11,0 , _ BE RELOCATED 3 0�2 ».».»._.. .».W.».:». . »» ..... — G FIRE SPRINKLER i -- - a� - HEAD TO REMAIN - PLUG '< A. T Rod i 2­2 . •. : . ,<.::�.:.,,.r w DENOTES FIRE SPRINKLER HEAD TO w fs `1. BE REMOVED AND OUTLET TO BE 112 112 114 11 1 1 PLUGGED DENOTES FiRE SPRINKLER PIPE TO 2 BE REMOVED AND OUTLET TO BE CV o I 5 Hanger Ring PLUGGED 114 112 112 2 2 2 �� _ 2�_ _ µ� NOTE r r, 1 1.TOTAL AREA PART OF CONTRACT IS APP..WET SYSTEM ±10,890 sq.lt 0-10 °— —®- — — — — — — — 1 — .• �' HANGER 2.ALL PiPE FOR WET SYSTEM 1"TO 2"SCH 40 BLACK PIPE FOR BRANCH LINES j N DETAIL 12-53.ALL PIPE FOR WET SYSTEM 2%"AND UP SCH 10 BLACK PIPE FOR MAIN LINES c...... SCALE: NOT TO SCALE 1 1 114 112 112 2 2 2 2 112 0-11 MAXIMUM DISTANCE BETWEEN HANGERS • St. t;..'• R' o�- - - - - - - - - - - - } - - - - - - - - -£O} - - - - - - - - - - - — � — } - - - - - -�- -- 112 114 1 . %. . Y _. 4..x ' A 1: t: ""` 8/1��.'s. . -' NNMINAL PIPE SIZE (IN ) 3/ 1 1Y/ 1� 12-5 . ' 1 ', •• .. •. .• I // 1^! M / p / p / N / p / p / N / p / N / p , 1 ,. STEEL PIPE (EXCEPT THRD. LIGHTWALU - - - - - - _ _ _ _ _ — cs� �; N 0 �� 0 15 0 15 0 15 0 15 0 15 0 15 0 15 0 15 C 15 0 w rt S M. z • ...............*_,_.._:1 ........................... //1 < i s: -r s _. ,.,—:., _,,....... _:::::.,: ..:::::: .,,......................................... » CSI: ,. 'd°'i 2 -- .... •- : „ NOTE: HANGER LOCATION FR ESP; NKLER HEAD AT THE END OF BRANCH LINE TO BE A - p 1 T MAX 1 0 FROM 1 ;r✓, 1 _ . • #- SPRINKLER HEAD -- - - -- ----- -- - - - - - - - ----�-� � — - --- � �-a-- -- - --- - - .• c o a © o -- Nk 1 SPRINK FIRE r ___ __ .. ALL HANGERS PMMATIC ONLY, HANGERS AR '•• '' • •:._,.�' •: E TO BE INS AL�ED AS PER THE SCHEDULE ABOVE. Now, '. SH � � WING R , I ' � E, --- ------------------------ ----------- -- REVIEWED FOR CODE FIRE SPRINKLERSY§TEM FLOOR PLAN �� �•����� �� o E COMPLIANCE ��,• '`� ,. CITY OF ATLANTIC BEACH � o-y SEE PERMITS FOR ADDITIONAL SCALE: 3/16"=V-01) O REQUIREMENTS AND CONDITIONS ----- - ------------------- --------------------------------------- O � ------ ------------------------------ - ------------------------------------------------------------------ " REVIEWED BY. 1 l -------------------------------------------------------- -- ------------------ ---------------- --------- ----------------------------- ----------------------- DTE. ------------- ------------------------------------------------------ R 19 A Jae WEI) L- - -------------------------------------- -------- 8O �il� Fire rOventio t ' Y Q 5 20t�.29302 FIRE SPRINKLER HEADS LEGEND 4 NpS *, 0&�Ci,pr EP-rj0jV, 1004 STiq ''E 06; 1 ROBERT L. HINKLE, P.E. ISYM CN POSITION EINISH TEMP K ;NPT :SIN ;MFG. MODEL# SN, ,. 01.5A,SOr, .a i082i CHEATHAM TRAIL j) ` ' JACKSONVILLE, FL. 32223 �'. f3 � •* � (904) 268-6643 �O 9 9 UPR BRASS 15 5 5.6 0 +1 /2 : -- -- - ----- - �,�•...�M••" ----------- ------- ------- ----- ------------- ------ ------- ---- -- -- - }------------------------- ---- - 02 :�, QNAL FLA. REG. # 293 8 EXISTING PENDENT 155 5.60 1 /2" LTO REMAIN �`;' ^ a, � 1� • 7 EXISTIN PENDEN 1 155 5.60 :1 2„--�TO RELOCATED DATE G / C D OR REMOVED PROJECT I I I @4 5 EXIS TING UPRIGEd 1 155 5.60 1 /2” -1 0 REMAIN 4/22/2016 1 EXISTING UPRIGHT 155 5.60 1/2" TO RELOCATED OR REMOVED PET � Uv f t y DRAWN BY -- -- ------------ ------- ----- -- -------- ----------------------------------- -------------------- ---- ------ --------- :112" ------------------------ ---- ------ -- 1 2 PEND BRASS 1 �5 5.60 1 2 - - - 1021 Atlantic - retic Boul. v MA / Boulevard UNIT X77 Atlantic Beach, F'L 322331 ------------- APPROVAL U] �- AREA SCALE Fire Protection Sprinkler System Renovation Plan AS NOTED SHEET N0. ALLSOUTH SPRINKLER CO. 1 E 1 1525 BROADMOOR BLVD. 11762 MARCO BEACH DR., SUITE 4 ED BUF'ORD, GA 30518 JACKSONVILLE, FL 32224 CONTRACT NO. PHONE: 770-925-9099 PHONE: 904-928-9099 FAX: 770-381.-1.314 FAX: 904-517-5092