102 Aquatic Dr #303 energy calculations FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - ResidentiLPerformance Method
Project Name: Aquatic TownHomes-Bldgs-Unit 303 Builder Name: Tnbntlge Reside
'
Street Permit Office: Duval
City,Slate,Zip: Atlantic Beach,FL, Permit Number: FEB - 9 2017
Owner: TnBridge Residential Jurisdiction: Duva1261000 I
Design Location: FL,MAVPORT_NS County:: Duval(Florida Cl' ate J L.
L New construction or existing New(From Plans) 9. Wall Types(3111.1 sgft.) ,
2. Single family or multiple family Multi-family a.Frame-Wood,Common R=13.0 1677.80ft
b.Frame-Wood,Exlenor R=13.0 865.33 8'
3. Number of units,if multiple family 1 c.Frame-Wood,Exterior R=19.0 302.46ft
4. Numberol Sedrooms 2 d.other(we details) R= 265.508'
5. Is this a worst cow? No 10.Ceiling Types (690.0 sq8.) Insulation Area
a.Under ABic(Vented) R=30.0 690.008'
6. Conditioned floor area above grade(fie) 1471 b.N/A R= ft,
Conditioned floor area below grade(f') 0 .c N/A R= H'
11.Duds R 1
7. Windows(19D.9 sqR.) Description Area a.Sup:Attic,Rat:Garage,AH:Garage 6 1155
a. U-Factor: Dbl.U=0.30 190.898'
SHGC SHGC=0.25
b. U-Facloc N/A 82 12.Cooling systems kBtulhr Efficiency
SHGC: a.Central Unit 40.1 SEER 14.00
c. U-Factor: N/A ft,
SHGC: 13.Heating systems kBtuBa Efficiency
J. U-Factor. N/A f' a.Electric Heal Pump 31.3 HSPFa.20
SHGC:
Area Weighted Average Overhang Depth: 3.437 ft.
V
Area Weighted14.Hot water systems
Weighted Average SHGC: 0.250 y
8. Floor Types (1119.0 sqf.) Insulation Area a.Electric Cap 50 gallons
EF 0.950
a.Slab-On-Grade Edge Insulation R=0.0 635.00 ft' b. Conservation leaW-es
b.Floor over Garage R=13.0 449.00f None
c.other(see details) R= 35.008' 15.Credits Pstal
Glass/Floor Area: 0.130 Total Proposed Modified Loads: 39.44 PASS
Total Baseline Loads: 40.29
I hereby certify that the plans and specifications covered by Review of the plans and OF lot STq p�
this calculation are in compliance with the Florida Energy specifications covered by this y „ _ : Off,
Code. calculation indicates compliance
Lisandro Vazquez
2016-11-09 10:37: BefWithore
the Florida Energy Code.
PREPARED BY: _ Before construction is completed a� •' �
DATE: - - _._ 02 this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed,is in compliance Florida Statutes. •!1, �e
with the Florida Ener e. CaDWE'C1sV
OWNER/AGENT: BUILDING OFFICIAL:
DATE: /' �f DATE:
• Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
•Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with 8402.4.1.2.
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 On for whole house.
11/8/2016 9:49 AM EnergyGouge®USA-FleRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: Aquatic TownHomes-Bldg3- Bedrooms: 2 Address Type: Lot Information
Building Type: User Conditioned Area: 1471 Lot# 303
Owner: TriBridge Residential Total Stories: 3 Block/SubDivision: Bldg3,Unit 303
#of Units: 1 Worst Case: No PlatBook:
[Builder Name: Tribridge Residential Rotate Angle: 270 Street:
Permit Office: Duval Cross Ventilation: County: Duval
Jurisdiction: Duval 261000 Whole House Fan: City,State,Zip: Atlantic Beach,
Family Type: Multi-family FL,
New/ErJsting: New(From Plans)
Comment: Aquatic Townhomes(Building 3-Unit B2)
CLIMATE
/ IECC Design Temp Int Design Temp Healing Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,MAYPORT_NS FL_MAYPORT_NS 2 39 90 70 75 1037 61 Medium
BLOCKS
Number Name Area Volume
1 Blocks 1471 15077.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated
1 Whole House 1471 16077.8 Yes 3 2 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Cal
1 Slab-On-Grade Edge Insulatio Whole House 68 it 0 635 fP __ 0 1 0
2 Floor over Garage Whole House __ __ 449 ft• 13 0 1 0
3Raised Floor Whole House __ ___ 35 fl' 13 0 0 1
ROOF
J Rauf Gable Roof Solar SA Emill Emift Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Flat Composition shingles 692 IV Oft' While 0.75 No 0.9 No 0 0
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 No attic Vented 300 692 W V N
11/8/2016 9:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Whole House 30 Batt 6901? 0.11 Wood
WALLS
AdjacentSgin 11
T. Wall Typepate Cavity Width Height Sheathing Framing Solar Below
1 S=-E Exterior Frame-Woad Whole House 13 20 6 9 0 184.5W 0.23 0.5 0
2 N=>W Garage Frame-Wood Whole House 13 20 6 9 0 184.5ft 0.23 0.01 0
3 E=>N Garage Frame-Woad Whole House 13 3 0 9 0 27.O f2 0.23 0.01 0
4 W=>S Garage Frame-Wood Whole House 13 3 0 9 0 27.0 ft2 0.23 0.01 0
-5 E=>N Exterior Frame-Wood Whole House 13 7 10 10 6 82.3 W 0.23 0.5 0
8 S=>E Exterior Frame-Wood Whole House 13 13 4 10 6 140.0 ft2 0.23 0.5 0
7 N=>W Exterior Frame-Wootl Whole House 19 20 6 10 6 215.3112 0.23 0.5 0
8 S=>E Edenor Frame-Wood Whole House 13 20 6 11 6 235.8112 0.23 0.5 0
9 N=>W Exterior Frame-Wood Whole House 13 12 10 11 6 147.68' 0.23 0.5 0
10 N=>W Extenor Frame-Wood Whole House 19 7 7 11 6 87.2W 0.23 0.5 0
11 E=>N Neighbor Frame-Wood Whole House 13 8 0 9 72.0%' 0.23 0.01 0
12 W=>S Neighbor Frame-Wood Whole House 13 10 11 9 98.3W 0.23 0.01 0
13 E=>N Neighbor Frame-Wootl Whole House 13 31 0 10 6 325.502 0.23 0.01 0
14 W=>S Neighbor Frame-Wootl Whole House 13 38 10 10 6 407.8 ft2 0.23 0.01 0
15 E=>N Neighbor Frame-Wootl Whole House 13 33 8 11 6 387.2W 0.23 0.01 0
16 W=>S Neighbor Frame-Wootl Whole House 13 33 8 11 6 387.202 0.23 0.01 0
17 W=>S Garage Frame-Wood Whole House 13 3 0 9 0 27.002 0.23 0.01 0
18 S=>E Estero, Frame-Wood Whole House 13 7 2 10 6 75.3 f12 0.23 0.5 0
DOORS
# Dirt Door Type Space Stones U-Value Width Height Ansa
Fl In Ft In
1 S=>E Wood Whole House None AS 3 6 8 20W
2 E=>N Wood Whole House None .46 3 6 8 20112
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 270 degrees).
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
_ 1 S=>E 1 Metal Low-E Double yes 0.3 0.25 18.0 ft' 8 ft 0 in 1 R 0 in Drapeslblinds None
2 S=>E 6 Metal Low-E Double yes 0.3 0.25 64.0 ft2 8 It 0 in 1 It 0 in Drapes/birds None
3 N=>W 7 Metal Low Double yes 0.3 0.25 21.31P Oft O in 0 I O in Drapes/blinds None
4 S=>E 8 Metal Low-E Double yes 0.3 0.25 48.0 ft` 0 ft 0 in 0 It 0 in Drapes/blinds None
5 N=>W 9 Metal Low-E Double yes 0.3 0.25 32.0 ft2 0 It 0 in 0 It 0 in Drapes/blinds None
6 S=>E 18 Metal Low-E Double yes 0.3 0.25 7.6 ft2 O ft O in O it 0 in Drapes bhrds None
11/8/20169:49 AM EneigyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of
FORM R405-2014
GARAGE
# Floor Ars, Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 449 ft• 449 ft' 20 ft 98 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgI-A ACH ACH 50
1 Whclehouse Proposed ACH(50) .000456 1759.1 96.57 181.62 .4881 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Duds
1 Electric Heat Pump Split HSPF:8.2 31.3 Mill 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Duds
1 Central Unit Split SEER: 14 40.1 kB1u/hr 1575 dm 0.8 1 still
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use Sei Conservation
1 Electric None Garage 0.95 50 gal 80 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert IN Company Name System Model# Collector Model# Area Volume FEF
None None N'
DUCTS
--Supply— —Return Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RUFF Heat Cool
1 AWc 6 1158' Garege 70.88' Prop.Leak Free Garage —dm 44.1 dm 0.03 0.60 1 1
11/9/20169:49 AM EnergyGauge®USA-FlaRes2014 Section R4064.1 Compliant Software Page 4 of
FORM R405-2014
TEMPERATURES
Programabllinlee ThermostaJant
OIY FebID01 I Calling Fans:tr If Ju n AU rD0'SepIr 11 Oct IDDI ID01
Ve Mg ]Jan H Feb M M r Apr [ I MDoc
ay [j Jun f Jul A�ugg [ ]Sep [%)Oct [X)Nov H Dec
Thermostat Schedule: HERS 2006 Reference Home
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) FM 88 80 78 78 78 78 78 78 78 78 78 8
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 fib 66 66 68 68 68 68 68 68 fib
PM 68 68 68 68 68 68 68 68 68 68 66 fib
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
11/8/2016 9:49 AM EnergyGaugeW USA-FlaRes2014 Section R405 4.1 Compliant Soltware Page 5 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPedormance Index,the more efficient the home.
Atlantic Beach, FL,
1. New construction or etlsting New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Multifamily a*
Frame-Wood ft
Common R=13.0 1677.80 '
b.Frame-Wood,Exterior R=13.0 865.33 ft'
3. Number of units,if multiple family 1 C.Frame-Wood,Exterior R=19.0 302,468'
4. Number of Bedrooms 2 d.other(see details) R= 265.50 fF
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 690.00ft
6. Conditioned floor area(ft-) 1471 b.NIA R= ft'
T Windows" Description Area c.N/A R= ft'
a. U-Factor: Dbl,U=0.30 190.89 W 11.Ducts R ft
SHGCSHGC=0.25 a.Sup:Attic,Rel:Garage,AH:Garage 6 115
:
b. U-Factor: N/A ft'
SHGC: 12.Cooling systems katwhr Efficiency
c. U-Faotor: N/A ft' a.Central Unit 40.1 SEER:14.00
SHGC:
tl. U-FacSHGC r: N/A ft' 13.Heating systems katmhr Efficiency
SHGC:
Area Weighted Average Overhang Depth: 3.437 ft. a.Electric Heat Pump 31.3 HSPFS.20
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hol watar.yiumns Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 535.00 ft' a.Electric
EF.0.95
b.Floor over Garage R=13.0 449.00 ft' b. Conservation features
c.other(see tletails) R= 35.00 fF None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building F-C1iESTgT
Construction through the above energy saving features which will be installed (or exceeded) y0 _ F0
in this home before foal inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: �iJ Date: 02/ -7
Address of New Home: to hr y City/FL Zip: �} f h fl, ��COD Will
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, N not DEFAULT.
11/8/20169:49 AM EnergyGauge®USA-FlaRes2014 -Section R405,4.1 Compliant Software Pagel oft
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Peril Number:
Atlantic Beach,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
0 401.3 Energy performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display cad contains inforalion indicating the energy performance level and efficiencies of components
installed in a dwelling unit The building official shall verify that the EPL display cad completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
0 R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402A.1,1 shall be installed in
accordance with the manufacturers instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 thmugh B.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove tloors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdhah and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior tloors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Usrm2),and swinging doors no more than 0.5 cfm per square fool(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/V DMA/CSA 10111.&VA440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O 8402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 dm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate healing and cooling system.
0 R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electiicr sistance heat shall have controls
that,except during defrost,prevent supplemental heal operation when the heat pump compressor can meet the heating load.
0 8403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered duds and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2 7 2 of the Commercial Provisions of this code and shall be shown to meet dud tightness criteria by post-constmdion
or roughJn testing below.
Dud tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy hater certified in accordance with Section
553.99,Florida Statutes,or as authorized by Florida Statutes,to be'substantially leak free"by either of the following:
1. Post-construction lest:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned Floor area
when tested at a pressure differential of 0.1 inches ws.(25 Pa)across the entire system,including the manufacturers air handier enclosure.All
register boots shall be taped or otherwise sealed during the ted.
2. RoughAn test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturers air handler enclosure.All registers shall be
taped or otherwise sealed during the lest.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The local leakage test is not required for duds and air handlers located entirely within the building envelope.
2. Dud testing is not mandatory for buildings complying by Sedion R405 of this code.
11/8/2016 9:49 AM EnergyGaugelD USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3
rFORIM R405-2014
NDATORY REQUIREMENTS - (Continued)
R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105•F(41•C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can tum off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Haat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heal traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R4g3.4.4Walter heater eMciencies(Mandatory).
Q R403.4.4.1 Storage water heater temperature controls
R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature selling range shall be from 100°F to 140°F(3WC to 6WC).
R403.4.4.1.2 Shut down. A separate switch ora clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off,A separate valve shall be pmvided to permit the energy supplied to the main bunni
of combustion types of service wafer heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water healing equipment installed in residential units shall most the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requimmenk for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2./Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florda Solar Energy Center Directory of
Clarified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Soler Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tih angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed al an orientation within 45 dogmes of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
❑ R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathmom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturers product lines.The wnesponding latent capacity of the
equipment shall not be less than the calculated latent load.
11/8/20169:49 AM EnergyGaul USA-FlaRes2014 -Section R4054.1 Com Page 2 of
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded Performance data shall be used to select coolingronly equipment.This
selection shall be used to select coolinganly equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower chin provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single.and multifamily residential equipment sizing may be selected so that its coaling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with goad design practice.
O 8403.8.1.2 Heating equipment capacity
• R403.6.1.2.1 Heat pumps. Heal pumps sizing shall he based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heal pump total cooling capacity shall not be more Nan 1.15 times greater than the design cooling load.
• R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1,
• 8403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
0 R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and 0404 of the Commercial Provisions in lieu of Section R403.
0 R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting o0 the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
0 R403.9 Swimming Pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All Pool heaters shall he equipped with a readily accessible ono8 switch that is mounted
outside the heater to allow shutting oft the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-Orad pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for healers manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.58.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heal pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Lour Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically tum oft and on heaters and pumps according to a
preset schedule shall be installed on aV heaters and Pumps.Heaters,pumps and motors that have bulk in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Whom pumps are required to operate solar-and waste-heal-recovery pool healing systems.
3. Where pumps are powerad exclusively from on-site renewable generation.
O 8103.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor Pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
0 RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in Permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of pennanemy installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
0 R405.2 Performance ONLY. All ducts not enfirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O 8405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have suficent space,R-10 is allowed.
11/812016 9:49 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Aquatic TownHomes-Bldg3-Unit 303 Builder Name: Tribddge Residential
Street: Permit Office: Duval
City,State,Zip: Atlantic Beach, FL, Permit Number.
Owner: TriBridge Residential Jurisdiction: Duval 261000
Design Location: FL,MAVPORT_NS
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air harder in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doom to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subtoor decking.
The air harder shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the craWlspace walls.
Exposed earth in unwanted crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garege and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
Basketed doors
1 Vail 9:49 AM EneigyGauge®USA-FlaRes2014 Section R4054.1 Compliant Software Pagel oft
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Aquatic TownHomes-Bldg3-Unit 303 Builder Name'. Tnbridge Residential
Street: Pemlk Office: Duval
City,State,Zip: Atlantic Beach,FL, Permit Number:
Design Location: FL,MAVPORT_NS Jurisdiction: Duval261000
Cord.Floor Area:: 1471 si Cond.Volume: 15078 ..ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
CFM(50):
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: ELA.
1 Pa cfm EgLA:
2 Pa cfm ACH:
3 Pa cfm ACH(50):
4 Pa cfm
5 Pa cfm SLA:
6 Pa cfm
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rale of not exceeding 5 air changes per hour
in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doom,fireplace and stove doom shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdaft and flue dampers shall be closed,but not sealed beyond intended infiltration
conlrol measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doom for continuous ventilation systems and heal recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the lest,shall be turned o0;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage Where required by the code official, OFtHE ST9TF
performance results demonstrate compliance testing shall be conducted by an OA
with Florida Energy Code requirements in approved third party.A written -
accordance with Section R402.4.1.2. report of the results of the test shall
be signed by the third party
0
conducting the test and provided to o a
SIGNATURE: the code official.
PRINTED NAME: e�COD WE�J
DATE: BUILDING OFFICIAL:
DATE:
11/W0169A9AM EnergyGai USA-FlaRes2014 -Section R405.4.1 Compliant Software Paget oft
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Aquatic TownHomes-B1dg3-Unit 303 Builder Name: Tribbdge Residential
Street: Permit Office: Duval
City,State,Zip: Atlantic Beach,FL, Permit Number:
Design Location: FL,MAVPORT_NIS Junsti ction: Duva1261000
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Dud Leakage Test Values
Line System Outside Dud Leakage
1 System 1 dm25(Out)
2 System 2 dm25(Out)
3 System 3 dm25(Out)
4 System 4 cfm25(Oul)
5 Total House Sum lines 1.4
Duct System
Leakage Divide by
(Total Conditioned Floor Area)
_ 1Q"CUt)
I certify the tested dud leakage to outside, On, is
not greater than the proposed dud leakage On Dud tightness shall be verified by OFttiE ST4r�"
specified on Form R405-2014. testing to Section 803 of the RESNET
P Standards by an energy rater certified in �0
accordance with Section 553.99,
Florida Statutes. O
SIGNATURE:
PRINTED NAME: ` COO WE ems{
DATE: BUILDING OFFICIAL:
DATE:
11/6/20169:49 AM EnergyOauge®USA-FlaRes2014 -Section R405.4.1 Compliant S Page l oft
FORM R405-2014
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page) and an input summary checklist that can
be used for field verification (usually 4 pagesrmay be greater).
❑ Energy Performance Level(EPL)Display Card(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method.,
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report(usually one page)
111812016 9 49:19 AM EnergyGauge®-USRRPB v5.1 Page 1 of 1