102 Aquatic Dr #401 energy calculations REVISED 10/12/17 s ; — CITY OF ATLANTIC BEACH
800 Seminole Road
OCT 1 2 2017 I s Atlantic Beach,Florida 32233
��-_SFT - t�q�-•v
OF3IDiQ' T SFS -1
REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS l
Date 16112-A Revision to Issued Permit Corrections to Comments Permit# I
Project Address (82ol.�ti�;` l�f ;� �w��;c. �e�`�j� frL 37-233
Contractor/Contact Name
Phone Hoc! - 3(-'? - 1x52-0 Email
Description of Proposed Revision' /Corrections: Permit Fee Due $ 5 O,O d
Additional Increase in Building Value $ 0 Additional S.F. (9
By signing below,I pbloe— affirm the Revision is inclusive of the proposed changes.
(printed name)
7
Signatu Contractor/Agent((fontractor must sign if increase in valuation) Date
(Office Use Only)
ApprovedaAw-- Denied Not Applicable to Department
Revision/Plan Review Comments 'SCS . O C) It) `ip C'
�MZoning
t Review Required:
�
Reviewed By
Tree Administrator
Public Works
Public Utilities 1
Public Safety ate
Fire Services
uocuoign tnveiope iu:u,+uqwts4-umji-444u-tsauu-araHaHuuz)iri
FORM R405-2014
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page) and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level(EPL) Display Card(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report(usually one page)
EnergyGauge®-USRRPB v5.1
9/22/2017 9:46:42 AM Page 1 of 1
v ul llv.11 LI Ivulupu 1U.VYVY IJOY'V�JI-`*4`FV-OyVI,-fir OF10F1UV�/f"/
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Aquatic Townhomes-Bldg 4-Unit 401 Builder Name: Tribridge Residential
Street: Permit Office: Duval
City,State,Zip: Atlantic Beach, FL, Permit Number:
Owner: TriBridge Residential Jurisdiction: Duval 261000
Design Location: FL,MAYPORT_NS County:: Duval(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2867.6 sgft.) Insulation Area
2. Single family or multiple family Multi-family a. Frame-Wood, Exterior R=13.0 1593.20 ft2
b. Frame-Wood,Common R=13.0 797.50 ft2
3. Number of units,if multiple family 1 c. Frame-Wood, Exterior R=19.0 265.46 ft2
4. Number of Bedrooms 2 d.other(see details) R= 211.50 ft2
5. Is this a worst case? No 10.Ceiling Types (665.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 665.00 ft2
6. Conditioned floor area above grade(ft2) 1398 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c. N/A R= ft2
11. Ducts R ft2
7. Windows(253.3 sgft.) Description Area a.Sup:Attic,Ret:Garage,AH:Whole House 6 150
a. U-Factor: Dbl, U=0.30 253.33 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 40.1 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 31.3 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.250 14. Hot water systems
8. Floor Types (672.0 sgft.) Insulation Area a.Electric Cap:50 gallons
EF:0.950
a. Floor over Garage R=13.0 460.00 ft2 b. Conservation features
b.Slab-On-Grade Edge Insulation R=0.0 175.00 ft2 None
c.other(see details) R= 37.00 ft2 15.Credits Pstat
Glass/Floor Area: 0.181 Total Proposed Modified Loads: 45.68 PASS
Total Baseline Loads: 47.06
I hereby certify that the plans and specifications covered by Review of the plans and 4119E ST4
this calculation are in compliance with the Florida Energy specifications covered by this 1/� =
Code. NPe 'eF•, calculation indicates compliance r, '' ,';�
Doc t*fti�
Michael L. Berry, P �y 19y39y,3,
with the Florida Energy Code.
PREPARED BY: i I Before construction is completed V
DATE: 09-22-2017 Fea 2 �a$ .:;� this building will be inspected for 0
......��,' compliance with Section 553.908
9/22j ;b°ASFlorida Statutes.
I hereby certify that this building, as designed, is in compilance
with the Florida Energy Code. COp WE
OWNER/AGENT: BUILDING OFFIC L:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.051 Qn for whole house.
9/22/2017 9:46 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 5
UUGUJHyrI crlvt-lupe IU.U'+U41384-UD31-444V-D`JVIi-`JrtlH8HVV0/C/
FORM R405-2014
PROJECT
Title: Aquatic Townhomes-Bldg 4-U Bedrooms: 2 Address Type: Lot Information
Building Type: User Conditioned Area: 1398 Lot# 401
Owner: TriBridge Residential Total Stories: 3 Block/SubDivision: Bldg4, Unit 401
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Tribridge Residential Rotate Angle: 90 Street:
Permit Office: Duval Cross Ventilation: County: Duval
Jurisdiction: Duval 261000 Whole House Fan: City,State,Zip: Atlantic Beach,
Family Type: Multi-family FL,
New/Existing: New(From Plans)
Comment: Aquatic Townhomes(Building 4-Unit 401)
CLIMATE
ECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,MAYPORT NS FL MAYPORT NS 2 39 90 70 75 1037 61 Medium
BLOCKS
Number Name Area Volume
1 Block1 1398 14329.5
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Whole House 1398 14329.5 Yes 3 2 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Whole House 52 ft 0 175 ft2 ---- 0 1 0
2 Floor over Garage Whole House ---- ___- 460 ft2 13 0 1 0
3 Raised Floor Whole House -_-- ---- 37 ft2 0 1 0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
�/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Flat Composition shingles 667 ft2 28 ft2 White 0.75 No 0.9 No 0 4.8
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 No attic Vented 300 665 ft2 Y N
9/22/2017 9:46 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 2 of 5
DocuSign Envelope ID:64041384-0631-4440-B906-9FBA8Ao0b/F/
FORM R405-2014
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Whole House 30 Batt 665 ft2 0.11 Wood
WALLS
AdjacentSpace Cavity Width Height Sheathing Framing Solar Below
1 S=>W Exterior Frame-Wood Whole House 13 20 6 9 0 184.5 ft2 0.23 0.5 0
2 E=>S Neighbor Frame-Wood Whole House 13 10 11 9 0 98.3 ft2 0.23 0.01 0
3 W=>N Garage Frame-Wood Whole House 13 3 0 9 0 27.0 ft2 0.23 0.01 0
4 N=>E Garage Frame-Wood Whole House 13 20 6 9 0 184.5 ft2 0.23 0.01 0
5 W=>N Exterior Frame-Wood Whole House 13 8 0 9 0 72.0 ft2 0.23 0.5 0
6 S=>W Exterior Frame-Wood Whole House 13 20 6 10 6 215.3 ft2 0.23 0.5 0
7 E=>S Neighbor Frame-Wood Whole House 13 31 0 10 6 325.5 ft2 0.23 0.01 0
8 N=>E Exterior Frame-Wood Whole House 13 20 8 10 6 217.0 ft2 0.23 0.5 0
9 W=>N Exterior Frame-Wood Whole House 13 13 8 10 6 143.5 ft2 0.23 0.5 0
10 W=>N Exterior Frame-Wood Whole House 19 17 3 10 6 181.1 ft2 0.23 0.5 0
11 N=>E Exterior Frame-Wood Whole House 19 7 4 11 6 84.3 ft' 0.23 0.5 0
12 N=>E Exterior Frame-Wood Whole House 13 13 2 11 6 151.4 ft2 0.23 0.5 0
13 W=>N Exterior Frame-Wood Whole House 13 32 6 11 6 373.8 ft2 0.23 0.5 0
14 S=>W Exterior Frame-Wood Whole House 13 20 6 11 6 235.8 ft2 0.23 0.5 0
15 E=>S Neighbor Frame-Wood Whole House 13 32 6 11 6 373.8 ft2 0.23 0.01 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>E Wood Whole House None .46 3 6 8 20 ft2
2 W=>N Wood Whole House None .46 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 90 degrees).
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 S=>W 1 Metal Low-E Double Yes 0.3 0.25 22.7 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None
2 S=>W 6 Metal Low-E Double Yes 0.3 0.25 22.7 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None
3 N=>E 8 Metal Low-E Double Yes 0.3 0.25 32.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None
4 N=>E 8 Metal Low-E Double Yes 0.3 0.25 64.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None
5 W=>N 9 Metal Low-E Double Yes 0.3 0.25 32.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None
6 N=>E 12 Metal Low-E Double Yes 0.3 0.25 32.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None
7 S=>W 14 Metal Low-E Double Yes 0.3 0.25 48.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None
9/22/2017 9:46 AM EnergyGaugeO USA-v5.1 -Section R405.4.1 Compliant Software Page 3 of 5
DocuSign Envelope ID:04041384-OB31-4440-B90C-9FBA8AO057F7
FORM R405-2014
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 460 ft2 460 ft2 43 ft 9 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000456 1671.8 91.78 172.6 .4881 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.2 31.3 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 14 40.1 kBtu/hr 1575 cfm 0.8 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 80 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
�/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 150 ft2 Garage 70.8 ft2 Proposed Qn Whole Hou ---cfm 71.7 cfm 0.05 0.60 1 1
9/22/2017 9:46 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 5
DocuSign Envelope ID:64041384-OB31-4440-BUOU-9FBABAOOb/F/
FORM R405-2014
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cool in [ ]Jan [ Feb [[ ]]Mar Apr I IM
a rl Jun rl
Jul rl
Au rl
Se [ ]Oct ( ]Nov Dec
Heating [X]Jan f X�Feb [X]Mar Apr May Jun Jul AuSep []Oct [X]Nov Dec
Ventin [ ]Jan [ Feb [[XX]]Mar [X]A r May Jun Jul Aug Se [X]Oct N Nov H Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
9/22/2017 9:46 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 5 of 5
Uocuaign cnveiope IU-.L4u4i,sal+-uaoi-444u-ayuU-artsHaHuuoiri
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
, Atlantic Beach, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=13.0 1593.20 ft'
b.Frame-Wood,Common R=13.0 797.50 ft2
3. Number of units,if multiple family 1 c. Frame-Wood, Exterior R=19.0 265.46 ft2
4. Number of Bedrooms 2 d.other(see details) R= 211.50 ft2
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 665.00 ft2
6. Conditioned floor area(ft2) 1398 b.N/A R= ft2
7. Windows- Description Area c. N/A R= ft2
a. U-Factor: Dbl, U=0.30 253.33 ft2 11. Ducts R ft2
SHGC: SHGC=0.25 a.Sup:Attic,Ret:Garage,AH:Whole House 6 150
b. U-Factor: N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 40.1 SEER:14.00
SHGC:
d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 31.3 HSPF:8.20
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14. Hot water systems Cap: 50 gallons
a. Floor over Garage R=13.0 460.00 ft2 a.Electric
EF:0.95
b.Slab-On-Grade Edge Insulation R=0.0 175.00 ft2
b. Conservation features
c.other(see details) R= 37.00 ft2
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building F THE Sr
Construction through the above energy saving features which will be installed (or exceeded) 0
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. «,,,, 0
Builder Signature: Date: a
t
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/22/2017 9:47 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
UocuSign Envelope IU:C4041384-Ot131-4440-b9OU-9FBA8AOOb/rI
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
E
RESS: Permit Number:
Atlantic Beach, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
0 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
[Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section
553.993(5)or(7), Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A
written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust, intake, makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3. Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
0 R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
0 R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
0 R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7),
Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i), Florida Statutes,to be"substantially leak free"by either of
the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system, including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system, including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
9/22/2017 9:47 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3
DocuSign Envelope ID:04041384-OB31-4440-B90(;-9FBA8Ao0biri
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
O R403.4.4.1 Storage water heater temperature controls
R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential or Florida Building Code, Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load, but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
9/22/2017 9:47 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3
DocuSign Envelope ID:04041384-01331-4440-t39UG-9rt3At$AUUblrI
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
0 R403.6.1.2 Heating equipment capacity
R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space, R-10 is allowed.
9/22/2017 9:47 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3
DocuSign Envelope ID:C4041384-OB31-4440-B90C-9Ft3ABA005iri
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Aquatic Townhomes-Bldg 4-Unit 401 Builder Name: Tribridge Residential
Street: Permit Office: Duval
City,State,Zip: Atlantic Beach, FL, Permit Number:
Owner: TriBridge Residential Jurisdiction: Duval 261000
Design Location: FL,MAYPORT_NS
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
9/22/2017 9:48 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1
DocuSign Envelope ID:C4041384-OB31-4440-B90C-9FBA8AO057F/
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Aquatic Townhomes-Bldg 4-Unit 401 Builder Name: Tribridge Residential
Street: Permit Office: Duval
City,State,Zip: Atlantic Beach, FL, Permit Number:
Design Location: FL,MAYPORT_NS Jurisdiction: Duval 261000
Cond.Floor Area:: 1398 sq.ft. Cond.Volume: 14330 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data: CFM(50):
C: n: R:
ELA:
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: EgLA'
1 Pa cfm ACH:
2 Pa cfm SLA:
3 Pa cfm ACH(50)"
4 Pa cfm
' For prescriptive projects, tested leakage must be
5 Pa cfm <=7 ACH(50). For performance projects, tested
6 Pa cfm leakage must be <= the ACH(50) shown on Form
R405-2014 for this project.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour
in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by
either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(0, (g),or(i)or an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust, intake, makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems, if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage Testing shall be conducted by either 1 STg�
individuals as defined in Section O F
performance results demonstrate compliance 553.993(5) or(7), Florida Statutes or
with Florida Energy Code requirements in
accordance with Section R402.4.1.2.
individuals licensed as set forth in
Section 489.105(3)(f), (g), or(i)or an
approved third party. A written report -e a
of the results of the test shall be signed m °
SIGNATURE: by the third party conducting the test
PRINTED NAME: and provided to the code official. COD WE
BUILDING OFFICIAL:
DATE:
— - DATE:
9/22/2017 9:48 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1
uocuSlgn Envelope IU:U4U4lJ64-UES3l-444U-bIUU-yrCAt$AUU5/r/
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Aquatic Townhomes-Bldg 4-Unit 401 Builder Name: Tribridge Residential
Street: Permit Office: Duval
City,State,Zip: Atlantic Beach, FL, Permit Number:
Design Location: FL,MAYPORT_NS Jurisdiction: Duval 261000
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
1 System 1 cfm25(Out)
2 System 2 cfm25(Out)
3 System 3 cfm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines 1-4
Duct System
Divide by
Leakage
(Total Conditioned Floor Area)
_ (Qn,Out)
I certify the tested duct leakage to outside, Qn, is Iib ST
not greater than the proposed duct leakage Qn Duct tightness shall be verified by T OF - ATS
specified on Form R405-2014. testing to Section 803 of the RESNETti _ ; O�
Standards by either individuals as "
defined in Section 553.993(5)or(7),
Florida Statutes, or individuals licensed cc
SIGNATURE: as set forth in Section 489.105(3)(f),
(g), or(i), Florida Statutes.
PRINTED NAME: �G'pp WE
DATE: BUILDING OFFICIAL:
DATE:
9/22/2017 9:48 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
VVVUQ1Y1I CIIVCIVpv 1u.%aYUY 100Y-VOJ IIF I
Florida Building Code Duct Leakage Results
Builder: Triad Mechanical
Neighborhood: CNB Lot #: 400/401
Address: 120 Aquatic Dr
City: Atlantic Beach State: FL Permit#:
Square Footage: 1 398
Stage of Construction for Test
FIRough in with Air Handler [:]Rough in no Air Handier a✓ Post Construction
Duct Leakage Test Results:
Duct Leakage percent requirement: 3 %
System I CFM25 Square I Dud Leakage Location Pass or Fail
Footage CFM/1 ft.
71 7 1398 I 5.1 Garage I Fail
2 1
3 I I
4 _
5
F] PassUnj
Fail
9 . 20 . 17
Rating Company: SkyeTecL Inspection Dale
Rater Name. Todd RYkacZewski
Rater Signature: Todd RykacZewski
The Energy Code Experts
9570 R gerCY so,tee B'od Surae 410 jacxsorwft FL 32225
prior* 9,,4 482 4VjG t 1 866 SKYETEC
W-ww Sir re'rec com
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Aquatic Tmvnhomes-Bldg 4-Unit 401 Builder Name: Tribndge Residential
Street: Permit Once: Duval
City,State,Zip: Atlantic Beach,FL, Permit Number:
Owner: TnBridge Residential Jurisdiction: Duval261000
Design Location: FL,MAVPORT_NS County:: Duval(Florida Climate Zone 2 I
1. New construction or existing New(From Plans) 9. Wall Types(2867.6 son.) Insulation Area
2. Single family or multiple family MultHamily a.Frame-Wood,Exterior R=13.0 1593.20W
b.Frame-Wood,Common R=13.0 797.50 W
3. Number of units,it multiple family 1 c.Frame-Wood,Exterior R=19.0 265.46W
4. Number of Bedrooms 2 J.other(see details) R= 211.50W
5. IS Misaworsl case? No 10.Ceiling Types (665.0 sgfl.) Insulation Area
a.Under Aftic(Vented) R=30.0 665.00fe
6. Conditioned floor area above grade(R2) 1398 to WA R= W
Conditioned floor area below grade(ft') 0 c.WA R= W
11,Ducts R W
7. Windows(253.3 sgft.) Description Area a.Sup:Attic,Ret:Garage,AH:Whole House 6 150
a. U-Factor: Dbl,U=0.30 253.33 W
SHGC: SHGC=025
b. U-Factor NIA W 12.Cooling systems k8tulhr Efficiency
SHGC: a.Central Unit 40.1 SEER:14.00
c. UFactor: N/A W
SHGC: 13.Heating systemso. Minutia Efficiency
J. U-Factor: N/A ft2 a.Electric Heat Pump 31.3 HSPF:8.20
SHGC: R
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.250 14.Holwatarsyslelpfa
8. Floor Types (672.0 sgft.) Insulation Area a.Electric Cap 50 gallons
NEF 0.950
a.Floor over Garage R=13.0 460.00 ftb. onserveuon
' features
b.Slab-0n-Grade Edge Insulation R=0.0 175.0002 None
c.other(see details) R= 37.00 W 15,Credits Pstzl
Total Proposed Modified Loads: 45.04
GlasslFloor Area: 0.181 Total Baseline Loads: 47.06 PASS
I hereby certify that the plans and specifications covered by Review of the plans and THE S7,4 p
Miscalculation are in compliance with the Florida Energy specifications covered by this = = FOS,
Code. calculation indicates compliance
/ Lisandr0 Vazquez with the Florida Energy Code.
PREPARED BY: �/ 2016-11-09 10:39: Before construction is completed
DATE: -_-._.._' 55 this building will be inspected for �Iti a
compliance with Section 553.908 • c
I hereby certify that this building,as designed,is in compliance Florida Statutes. avf,
with the Flonda Energy Cop WE
0WNE.R/AGE T ��-- BUILDING OFFICIAL:
DATE: OZ�a I J DATE: 41;" \�l
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 8402.4.1.1 and an envelope leakage
teat report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 On for whole house.
11/8@0162:25 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: Aquatic Townhomes-Bldg 4-U Bedrooms: 2 Address Type: Lot Information
Building Type: User Conditioned Area: 1398 Lot# 401
Owner: Tri nage Residential Total Stories: 3 Block/SubDivision: Bldgs,Unit 401
#of Units: 1 Worst Case: No PlalBook:
Builder Name: Tribritlge Residential Rotate Angle: 0 Sireel:
Permit Office: Duval Cross Ventilation: County: Duval
Jurisdiction: Duva1281 W0 Whole House Fan: City,State,Zip: Atlantic Beach,
Family Type: Multifamily FL,
New/Ensting: New(From Plans)
Comment: Aquatic Townhomes(Builtling 4Unit 40 1)
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMV Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,MAVPORT_NS FL_MAVPORT_NS 2 39 90 70 75 1037 61 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1398 14329.5
SPACES
Number Name Area Volume KXchen Occupants Bedrooms Irlfil ID Finished Cooled Heated
1 Whole House 1398 14329.5 Yes 3 2 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel
1 Slab-On-Grade Edge Insulatio Whole House 52 X 0 175 fl' __ 0 1 0
2 Floor over Garage Whole House — —_ 460 1 13 0 1 0
3Raised Floor Whole House — .--- 37 ft• 0 1 0
ROOF
/ Roof Gable Roof Solar SA Emig Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Flat Composition shingles 667X' 28X' White 0.75 No 0.9 No 0 4.8
ATTIC
V # Type Ventilation Vent Ratio(I in) Area RBS IRCC
1 No attic Vented 300 665 X2 Y N
1102016 2:25 PM EnergyGauge®USA-FlaRes2014 Section 8405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
A Ceiling Type Specs R-Value Ins Type Area Framing Frac Trues Type
1 Under Attic(Vented) Whole House 30 Bell 66511' 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
W211 4pe
_ 1 W Exterior Frame-Wood Whole House 13 20 6 9 0 184.5 ft' 0.23 0.5 0
-2 S Neighbor Frame-Wood Whole House 13 10 11 9 0 98.3 ft' 0.23 0.01 0
3 N Garage Frame-Wood Whole House 13 3 0 9 0 27.0W 0.23 0.01 0
4 E Garage Frame-Wood Whole House 13 20 6 9 0 184.5W 0.23 0.01 0
5 N EAenor Frame-Wootl Whole House 13 8 0 9 0 72.0 fN 0.23 0.5 0
fi W Exterior Frame-Wood Whole House 13 20 6 10 6 215.3 IF 0.23 0.5 0
S Neighbor Frame-Wood Whole House 13 31 0 10 6 325.5ft 0.23 0.01 0
8 E Edenor Frame-Wood Whole House 13 20 8 10 6 217.0 ft' 0.23 0.5 0
9 N Exterior Frame-Wood Whole House 13 13 8 10 6 143.5 ft' 0.23 0.5 0
10 N Exterior Frame-Wootl Whole House 19 17 3 10 6 181.1 ft' 0.23 0.5 0
11 E Exterior Frame-Wootl Whole House 19 7 4 11 6 84.3112 0.23 0.5 0
12 E Eiden" Frame-Wootl Whole House 13 13 2 11 6 151.4 ft' 0.23 0.5 0
13 N Exterior Frame-Wootl Whole House 13 32 6 11 6 373.8W 0.23 0.5 0
14 W Extenor Frame-Wood Whole House 13 20 6 11 6 235.8 ft' 0.23 0.5 0
15 S Neighbor Frame-Wood Whole House 13 32 6 11 6 373.8 I12 0.23 0.01 0
DOORS
M Omit Door Type Space Storms U-Value Width Height Ares
Fl In FI In
1 N Wand Whole House None .48 3 6 8 20ft
2 N Wood Whole House None .46 3 6 8 20 ft'
WINDOWS
Orientation shown is the entered,Proposed orlerdation.
Wall Overhang
V M Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 W 1 Metal Low-E Double Yes 0.3 0.25 22.7112 0 I 0 in 0 It 0 in Drapaslblinds None
_ 2 W 6 Metal Low-E Double Yes 0.3 0.25 22.7 ft- 0 ft 0 in 0It0 in Drapes/blinds None
3 E 8 Metal Low-E Double Yes 0.3 0.25 32.0 ft- 0 It 0 in 0 It 0 in Drapes/blinds None
4 E 8 Metal Low-E Double Yes 0.3 0.25 64.0 ft' 0 It 0 in 0 ft 0 in Drapes/blinds None
5 N 9 Metal Low-E Double Yes 0.3 0.25 32.0 fl' 0 It 0 in 0 ft 0 in Drapeslblinds None
6 E 12 Metal Low-E Double Yes 0.3 0.25 32.0 fl' 0 It 0 in 0 ft 0 in Drapasiblinds None
7 W 14 Metal Low-E Double Yes 0.3 0.25 48.0 Ili 0It0 in 0It0 in Drapes/blinds None
1118/20162:25 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Paye3 of -
FORM R405-2014
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 460 ft' 460ft 43ft 9f 1
INFILTRATION
It Scope Method SLA CFM 50 ELA EgLA ACH ACH 60
1 Wholehouse Proposed ACH(50) .000456 1671.8 9178 172.6 4881 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Duds
1 Electric Heat Pump Split HSPF:8.2 31.3 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Duds
1 Central Unit SPIR SFFR 14 40.1 kBtwTr 1575 chin 0.8 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 80 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model If Area Volume FEF
None None ft'
DUCTS
—Supply— —Return-- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 A01c 6 150 ft' Garage 70.8 fP Prop.Leak Free Whola Hou —dm 419cfm 0.03 0.60 1 1
11/8/2016 2:25 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
TEMPERATURES
Programablling reD01Thennoslatt0Jan1Y Ceiling Fans:Feb Mar yfr Ir IDD' f 11D01 fD0'
ID
VeBng [ J Jan 1 ]F b P(7 Mar [X) MaApr jjM.
y [ Jun [ Jul [ ]AugA gg II Sep P9 Oct00 [X)Na,
v ` ]Dec
Theimoslat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 8 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(VIVID) AM 66 66 66 66 66 68 fib 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM fib 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 fib 66
11/8/2016 2:25 PM EneigyGai USA-HaRe52014 Section R405 4.1 Compliant Software Page 5 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX' = 96
The lower the EnergyPerformance Index,the more efficient the home.
, Atlantic Beach, FL,
1. New construction or eristing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=13.0 1593.20 fF
b.Frame-Wood,Common R=13.0 797.50ft
3. Number of units,if multiple family 1 c.Frame-Wood,Exterior R=19.0 265.46 It
4. Number of Bedrooms 2 d.other(see details) R= 211.50 k'
5. Is this a worst rase? No 10.Ceiling Types Insulation Area
e.Under Atiic(Vented) R=30.0 665.00 IF
6. Conditioned floor area(ft') 1398 b.N/A R= IF
7. Windows- DescriptionArea c.N/A R= k'
a. U-Factor: Dbl,U-0.30 253.33 W 11.Ducts R ft'
SHGC: SHGC=0.25 a.Sup:Akb,Rel:Garage,AH:Whole House 6 150
b. U-Factor: N/A f,
SHGC: 12.Cooling systems kBtwhr Efficiency
c. U-Factor. N/A k' a.Central Unit 40.1 SEER:14.00
SHGC:
tl. U-FacSHGC r: N/A k' 13.Heating systems kStumr Efficiency
SHGC:
Area Weighted Average Overhang Depth: 0.000 k. a.Electric Heat Pump 31.3 HSPF:8.20
Area Weighted Average SHGC: 0.250
8. Floor Types Insulation Area 14.Hot water systems Cap:50 gallons
a.Floor over Garage R=13.0 460.00 W a.Electric
EF:0.95
0.Slab-On-Grade Edge Insulation R=0.0 175.00 k'
c.other(see details) R= 37.00 ft• b. Conservation features
None
15.Credits Paten
I certify that this home has complied with the Florida Energy Efficiency Code for Building FTtiE STgp
Construction through the above energy saving features which will be installed (or exceeded) JVD FG
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. +� •, �o
aS �
Builder Signature: Date: 2Z/eg/17 " a
Address of New ome: � r )Z City/FL Zip: / r.i1'1 , aa�D WE'1R�>
3za�y
'Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/8/2016 2:26 PM EnergyGauge®USA-FlaRes2014 -Section 8405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Permit Number:
Atlantic Beach,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be aco.rale and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Flonda Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall vent'that the EPL display cartl completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and 84024.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturers instructions and the create listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the parry conducting the test and provided to the code
official,Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exlenor windows and doors,fireplace and stove doom shall be closed but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampen:shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the lest,shall be open;
4.Exterior doom for continuous ventilation systems and heat recovery ventilators shall be closed and sealed,
5.Heating and cooling systems,if iinstalled at the time of the test,shall be fumed off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
0 R402.4.2 Fireplaces. New wootl-buming fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
0 R402.4.3 Fenestration air leakage.W indows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(IS Uslm2),and swinging doors no more than 0 5 don per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMAANDMAICSA 101/LS.2IA440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
0 R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditionetl and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 chn(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
❑ R403.1.1 Thermostat provision(Mandatory). Al leas[one thermostat shall be provided for each separate hearing and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary eledrr-resistance heat shall have controls
Nal,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.2.2 Sealing(Mandetory)All ducts,air handlers,and filler boxes and building cavities that font the primary air containment
passageways for air distribution systems shall be considered duds and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2].2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99,Florida Statutes,or as authorized!by Florida Statutes,to be'substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 dm(113 Umin)per 100 square feel(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the enfire system,including the manufacturers air handier enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in lest:Total leakage shall be less than or equal to 4 dm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturers air handler enclosure.All registers shall be
taped or otherwise sealed during the lest.If the air handier is not installed at the time of the test,total leakage shall be less than or equal to 3 don
(85 Umin)per 100 square feet(9.29 m2)of conditionetl floor area.
Exceptions:
1. The total leakage test is not required for duds and air handlers located entirely within the building envelope.
2. Dud testing is not mandatory for buildings complying by Section R405 of this code.
11/8/20162:26 PM EnergyGauge®USA-FlaRes2014 -Section R4054.1 Com Pagel of
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 10VF(41'C)
or below 55-F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
0 R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can tum off the hot-water circulating pump when the system is not in use.
0 R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having veriiwl pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downwartl and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
0 R403.4.4 Water heater efficiencies(Mandatory).
O R403.4.4.1 Storage water heater temperature controls
• R403.4.4.1.1 Automatic controls. Service water healing systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable lemperetme settings for the intended use.The minimum
temperature setting range shall be from 100°F to 14VF(38°C to 601
• R403.41A.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burners)
of combustion types of service water heating systems to be turned off.
O 8403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table 0404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as pad of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Codified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors.
and SRCC Standard TM-1,Solar Domestic Hal Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed al an orientation within 45 degrees of true south.
0 8403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Flodtla Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
0 8403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for coding and heating equipment.
O 8403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based an the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(8 split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described In Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• 8403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturers product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
11/8/20162:26 PM EnegyGai USA-FlaRes2014 -Section R4054.1 Com Page 2 of
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-ony,equipment.This
selection shall be used to select ccoling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower clot provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return ducl(e)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment maybe sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
• R403.6.1.2.1 Haat pumps. Heat pumps sizing shall be based an the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
• 11403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
• R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1,
O 8403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or healing equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or healing system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periotls is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow men system controls(Mandatory). Snow and ice-mening systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F.
❑ 11lull Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSVAPSP-15.The energy
requirements for portable spas shall be in accordance with ANSIIAPSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-oft switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heal pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard,
O R403.9.2 Tim.switches. Time switches or other control method that can automatically tum off and on heaters and pumps according to a
preset schedule shall be installed on all healers and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate soler-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant coveron or
at the water surface or a liquid cover or other means proven to reduce heat lass.
Exception: Outdoor pools deriving over TO Percent of the energy for heating from site-recovered energy,such as a haat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not he required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space,R-10 is allowed.
1118/2016 2:26 PM EnergyGaul USA-FlaRell -Section R405.4.1 Com Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Aquatic Townhomes-Bldg 4-Unit 401 Builder Name: Tdbddge Residential
Street: Permit Office: Duval
City,State,Zip: Atlantic Beach,Fit , Permit Number:
Owner: Trani Residential Jurisdiction: Duval 261000
Design Location: FL,MAVPORT_INS
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air bander shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim 'oists Rim joists are insulated and include an air bander.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be cevered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Bad insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air banner shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall he
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
11/6/2016 2:26 PM EnergyGaui USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Aquatic Townhomes-Bldg 4-Unit 401 Builder Name: Tnbndge Residential
Street: Permit Office: Duval
City,State,Zip: Atlantic Beach,FL Permit Number:
Design Location: FL,MAVPORT_NS Jurisdiction: D.va1261000
Cord.Floor Area:: 1398 sq.ff. Cond.volume: 14330 cu R.
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
Single or Mufti Point Test Data
HOUSE PRESSURE FLOW: ELA'
1 Pa cfm EgLA:
2 Pa cfm ACH:
3 Pe c1r^ ACH(50):
4 Pa Cfm
SLA:
5 Pa cfm
6 Pa cfm
R402.4.1.2 Tasting. The building or dwelling unit shall be tested and verified as having an air leakage rate of not something 5 air changes per hour
in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through B.Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g.(50 Pascals).Whom required by the code official,testing shall be conducted by an approved third party.A written report of the results of the
test shall be signed by the perry conducting the lest and provided to the code official.Testing shall be performed at any time after creation of all
Penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraff and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed,
5.Healing and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage Where required by the code official, OF'THB ST4pff
performance results demonstrate compliance testing shall be conducted by an
with Florida Energy Code requirements in approved third party.A written
accordance with Section R402.4.1.2. report of the results of the test shall SS
be signed by the third party
conducting the test and provided to
SIGNATURE: the code official.
PRINTED NAME: OWE
BUILDING OFFICIAL:
DATE: DATE:
11/82016 2:26 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page i of 1
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Aquatic Tovinhomes-Bldg 4-Unit 401 Builder Name'. Tribddge Residential
Street Permit Office'. Duval
City,State,Zip: Atlantic Beach,FL, Permit Number:
Design Location: FL,MAVPORT_NS Jurisdiction: Duval 261000
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
1 System 1 dm25(Out)
2 System 2 cfm25(Out)
3 System 3 dm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines 14
Duct System
Leakage Divide by
(Total Conditioned FloorArea)
Rn,Out)
I certify the tested duct leakage to outside, On, is ST
not greater than the proposed duct leakage On Dud tightness shall be verified by f-fm q�
specified on Form R405-2014. testing to Section 803 of the RESNET �Y , a i OA
Standards by an energy rater certified in -J,
accordance with Section 553.99,
r. jr, '` �.
Florida Statutes. O
SIGNATURE:
e
PRINTED NAME: * COO WE
DATE: BUILDING OFFICIAL:
DATE:
11/8@016 2:26 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Complient 8 Page 1 of 1
FORM R405-2014
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page) and an input summary checklist that can
be used for field verification (usually 4 pagealmay be greater).
❑ Energy Performance Level(EPL)Display Card(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage', then a completed
Form R405 Duct Leakage Test Report(usually one page)
ErergyGauge®-USRRP6 v5.1
11/8/2016 2:25:55 PM f age 1 of i