Loading...
1021 ATLANTIC BLVD #953-975 - FIRE COMMENTS - � LA4-f� City of Atlantic Beach APPLICATION NUMBER s , �' Building Department (To be assigned by the Building Department.) y:a 800 Seminole Road /) / Q /�/ 1:1,1:1, U]WY!Atlantic Beach, Florida 32233-5445 U M[Q -Oo 7 \ Phone(904)247-5826 • Fax(904)247-5845 /_ / ,:; q�0;1� E-mail: building-dept@coab.us Date routed: 4 L 11l i0p City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: (021 kaili-fic..... 953 -4775:lepartment review required Yes No //^' uilding� Applicant: mi° S( G L�O R,S l•1.- \olr\ Planning &Zoning Tree Administrator Project: (Re 0‘./64e- RC54—cutia,ni- Public Works Public Utilities kb become Ju J t 0 P • ety F e Service Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. ['Not applicable (Circle one.) Comments: ( BUILDING S rra•4%J PLANNING &ZONING Reviewed by: ./....4e5.7 eC,errr Date: 4`/ 1j TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 • S 6°E k. Y S 9.450E Fire Plans Review Fire Prevention Division 214 N. Hogan Street, Room 281 Jacksonville, Florida 32202 June 27, 2018 Jumpin Jax 1021 Atlantic Blvd COMM 18-0017 The Drawings submitted for permitting have been reviewed and Returned for Corrections. Please correct or provide the proceeding requested information to obtain plans approval. When resubmitting corrected sheets, please provide a written narrative letter responding to our comments and directing the plans reviewer to the sheets the changes have taken place. FAILURE TO SUPPLY RESPONSE LETTER "WILL" RESULT IN A RETURNED FOR CORRECTIONS PERMIT STATUS. Revised sheets should be clouded clearly showing areas were changes or corrections have occurred and re-inserted with the original set of drawings with old sheets removed. Unbound plans will not be reviewed. If this is an electronic submission please make sure that written narrative is submitted under correspondence along with a "complete set" (not just the revised sheets) of electronic documents. The Drawings Indicate a Dining Area With an Occupant Load of 76. Additional Seating Has Been Submitted For an Occupant Load Increase of 100. 1.) Please Address the Seating that Abuts the Aisle. The Required Distances are not in Accordance with the 6th Edition FFPC, 12.2.5.8 "Aisles Serving Seating at Table" Aisle -An unenclosed exit access component that defines and provides a path of egress travel. In the case of banquet seating, it can be expressed as the portion of the exit access that leads to a cross aisle or a marked exit door. 1.) • The 36 inches minimum between two adjacent tables without any chair backs facing each other. 2.) • 55 inches minimum between two adjacent tables when one has a chair back facing the other. 3.) • 74 inches minimum between two adjacent tables with chairs "back-to-back."