Loading...
533 ATLANTIC BEACH CT - TRUSSES i t Claddagh Construction r Site Information Roick Residence, Duval+ Structural Engineer of Record Christopher C. Kathe PE No. 36820 It 420 Osceola Ave. TrueHouse Jacksonville Beach, FL WIND LGADING(Cd=1 .6) ROOF LOADING (Cd=1 .25) FLOOR LOADING (Cd = 1 .00) MWFRS 1 TCLL 20 psf 4/ TOLL 40 psf 4/ 130MPH(3 second gust)\ASCE?-10 +/ TOOL 10 psf4/ TOOL 15 psf It Enclosed Structure (0.18) BOLL 0 psf + NCLL 10 psf BOLL 0 psf Exposure D./ BCDL 10 psf 1 BCDL 10 psf A/ Occupancy Category II (Res)+/ FBC 2017 RES\TPI 2014 This Package inlcudes 76 truss designs with individual date of design NO JOB ID TRS ID DATE i. NO JOB ID TRS ID DATE PNO i JOB ID TRS ID DATE 1 76238 F01 7/19/2018 29 76238 GE07 7/19/2018 57 76238 T15 7/19/2018 2 76238 F02 7/19/2018 30 76238 X08 7/19/2018 58 76238 T16 7/19/2018 3 76238 F03 7/19/2018 31 76238 GEN 7/19/2018 59 76238 T17 7/19/2018 4 76238 FG01 7/19/2018 32 76238 GE10 7/19/2018 60 76238 T18 7/19/2018 5 76238 FG02 7/19/2018 33 76238 l-1,101 7/19/2018 61 76238 T19 7/19/2018 6 76238 FG03 7/19/2018 34 76238 ,101 7/19/2018 62 76238 120 7/19/2018 7 76238 FG04 7/19/2018 35 76238 .02 7/19/2018 63 76238 T21 7/19/2018 8 76238 FG05 7/19/2018 36 76238 J33 7/19/2018 64 76238 122 7/19/2018 9 76238 FG06 7/19/2018 37 76238 J34 7/19/2018 65 76238 123 7/19/2018 10 76238 FG07 7/19/2018 38 76238 J05 7/19/2018 66 76238 124 7/19/2018 11 76238 FG08 7/19/2018 39 76238 .06 7/19/2018 67 76238 125 7/19/2018 12 76238 FG09 7/19/2018 40 76238 J07 7/19/2018 68 76238 126 7/19/2018 13 76238 FG10 7/19/2018 41 76238 ,108 7/19/2018 69 76238 129 7/19/2018 14 76238 FG11 7/19/2018 42 76238 P601 7/19/2018 70 76238 T30 7/19/2018 15 76238 FG12 7/19/2018 43 76238 101 7/19/2018 71 76238 131 7/19/2018 16 76238 FG13 7/19/2018 44 76238 1D2 7/19/2018 72 76238 132 7/19/2018 17 76238 FG14 7/19/2018 45 76238 103 7/19/2018 73 76238 T33 7/19/2018 18 76238 FG15 7/19/2018 46 76238 T04 7/19/2018 74 76238 T34 7/19/2018 19 76238 FG16 7/19/2018 47 76238 105 7/19/2018 75 76238 T35 7/19/2018 20 76238 FGE01 7/19/2018 48 76238 106 7/19/2018 76 76238 136 7/19/2018 21 76238 FGE02 7/19/2018 49 76238 107 7/19/ail"' 22 76238 FGE03 7/19/2018 50 76238 108 7/19/2 o Reviewed o Rejected • Approved as Noted 23 76238 G7/19/2 1 7/19/2018 51 76238 1D9 o Revise and Resubmit 24 76238 GE02 7/19/2018 52 76238 T10 7/19/2 o Submit Specific Item 25 76238 GE03 7/19/2018 53 76238 T11 7/19/2 This review is for general compliance with the design 26 76238 GEN 7/19/2018 54 76238 112 7/19/2 concept given in the Contract Documents. The 7/19/2 corrections and comments on this review does not 27 76238 GE05 7/19/2018 55 76238 T13 relieve Contractor from compliance with the 28 76238 GE06 7/19/2018 56 76238 T14 7/19/2 requirements of the plans and specifications. Contractor is responsible for dimensions to be Apex Technology is a ficticious name owned byJ3xApex Technology,Inc.,a Florida Corp confirmed and correlated at the job site; information Engineer Business No.7547-4745 Sutton Park urt,Suite 402 Jacksonville,FL 3222 for the fabrication processes or to the means, (h methods,techniques,sequences and procedures of construction;coordination of their work with all trades: The seal on this index sheet indicates acceptance of professional engineering responsit and performing work in a safe and satisfactory lf*/\ Truss Design Drawings listed above and attached. The suitability and use of each drawi manner. particualr building is the responsibility of the Building Designer,per ANSI/TPI 1-2002 Se Date 10/09/2018 By: Christopher Kathe With my seal affixed to this sheet,I hereby certify that this serves as an index sheet in a CHRISTOPHER C.KATHE, INC APEXRule 61G15-23.002(2)and 61G15-31.003 of the Florida Board of Professional Enginee This document may be signed and sealed with original or Docusign digital signature by t nrnfpssinnal 1 engineer identified in the adjacent professional engineer's seal.Printed copies of Docus 1. SEE STRUCTURAL SHEETS 11 documents are not considered signed and sealed and the signature must be verified on FOR REQUIRED UPLIFT CONNECTORS copies. 1 1 Job#76238 BEARING INFORMATION WOODTRUSS QTY SPAN DESCRIPTION BRG# REACTION UPLIFT 1 36'06"00 FG01 COMN 10.25/12 Pitch 3-Ply 1 2035.55 74.00 2 7974.53 1307.00 3 2028.91 477.00 9 18'06"00 FG02 SPEC 10.25/12 Pitch 1 -Ply 1 1125.04 172.00 2 919.91 176.00 1 33'02"00 FG03 COMN 10.25/12 Pitch 3-Ply 1 2093.11 105.00 2 6521.59 1050.00 3 2464.80 564.00 3 33'02"00 FG04 COMN 10.25/12 Pitch 1 -Ply 1 1243.29 170.00 2 2560.05 405.00 3 906.62 124.00 2 3302"00 FG05 COMN 10.25/12 Pitch 1 -Ply 1 1186.40 162.00 2 3242.55 448.00 3 1525.02 141.00 4 3302"00 FG06 COMN 10.25/12 Pitch 1 -Ply 1 1261.33 174.00 2 2223.99 355.00 3 790.19 119.00 3 36'06"00 FG07 COMN 10.25/12 Pitch 1 -Ply 1 1201.74 205.00 2 2923.05 458.00 3 1081.15 182.00 1 36'06"00 FG08 COMN 10.25/12 Pitch 2-Ply 1 2402.66 232.00 2 4002.63 514.00 3 1042.66 190.00 6 36'06"00 FG09 COMN 0.00/12 Pitch 1 -Ply 1 927.70 151.00 2 2640.66 407.00 3 1067.24 186.00 2 36'06"00 FG10 COMN 0.00/12 Pitch 1 -Ply 1 927.40 147.00 2 2640.66 407.00 3 916.77 138.00 1 36'06"00 FG11 COMN 0.00/12 Pitch 1 -Ply 1 927.33 147.00 2 2642.06 407.00 3 915.49 137.00 1 36'06"00 FG12 COMN 10.25/12 Pitch 2-Ply 1 2520.47 159.00 2 4618.36 506.00 3 763.84 128.00 1 11'10"04 FG13 MONO 0.00/12 Pitch 2-Ply 1 5005.34 I 763.00 2 4864.28 737.00 1 2311°00 FG14 MONO 0.00/12 Pitch 4-Ply 1 . •.• 0.00 2 6150.97 0.00 1 23'11"00 FG15 MONO 0.00/12 Pitch 4-Ply 1 6052.39 0.00 2 6052.39 0.00 1 16'07"08 FG16 FLAT 0.00/12 Pitch 2-Ply 1 3075.62 0.00 2 3075.62 0.00 2 12'08"00 GE01 GABL 9.00/12 Pitch 1 -Ply 1 1356.55 625.00 1 06'00"00 GE02 GABL 9.00/12 Pitch 1 -Ply 1 650.00 194.00 1 36'06"00 GE03 GABL 10.25/12 Pitch 1 -Ply 1 1742.27 633.00 2 357.78 56.00 1 36'06"00 GE04 GABL 10.25/12 Pitch 1 -Ply 1 490.65 96.00 2 1155.12 474.00 Page 1 of 4 t Job#76238 BEARING INFORMATION OTY SPAN DESCRIPTION BRG# REACTION UPLIFT 3 479.92 86.00 1 24'00"00 GE05 GABL 9.00/12 Pitch 1 -Ply 1 2446.67 703.00 1 19'06"00 GE06 GABL 9.00/12 Pitch 1 -Ply 1 1048.16 304.00 2 1092.69 304.00 1 16'08"00 GE07 GABL 9.00/12 Pitch 1 -Ply 1 1696.67 533.00 1 13'08"00 GE08 GABL 9.00/12 Pitch 1 -Ply 1 1441.67 453.00 1 05'00"08 GE09 GABL 9.00/12 Pitch 1 -Ply 1 533.54 167.00 2 17'08"00 GE10 GABL 9.00/12 Pitch 1 -Ply 1 174.16 154.00 2 1310.89 496.00 3 95.39 61.00 4 02'10"11 HJ01 HIP JACK 6.76/12 Pitch 1 -Ply 1 352.46 135.00 2 58.43 21.00 3 60.42 43.00 4 02'00"00 J01 EJACK 10.25/12 Pitch 1 -Ply 1 291.06 73.00 2 34.73 17.00 3 57.67 36.00 1 02'00"00 J02 EJACK 10.25/12 Pitch 1 -Ply 1 93.09 0.00 2 36.52 2.00 3 57.67 58.00 15 04'00"00 J03 JACK 9.00/12 Pitch 1 -Ply 1 358.06 73.00 2 68.33 3.00 3 115.50 86.00 3 04'00'00 J04 JACK 9.00/12 Pitch 1 -Ply 1 415.13 200.00 2 127.79 49.00 3 108.68 51.00 6 07'00"00 J05 JACK 9.00/12 Pitch 1 -Ply 1 478.89 31.00 2 155.70 0.00 3 203.73 113.00 1 07'00"00 J06 JACK 9.00/12 Pitch 1 -Ply 1 478.89 31.00 2 155.70 0.00 3 203.73 110.00 1 07'00"00 J07 JACK 9.00/12 Pitch 1 -Ply 1 467.22 58.00 2 163.40 46.00 3 127.72 47.00 1 07'00"00 J08 JACK 9.00/12 Pitch 1 -Ply 1 541.93 266.00 2 143.47 39.00 3 200.09 102.00 10 -5'-5"00 PB01 COMN 10.25/12 Pitch 1 -Ply 1 137.93 171.00 2 720.39 406.00 3 131.70 106.00 2 16'09"00 T01 COMN 10.25/12 Pitch 1 -Ply 1 731.79 212.00 2 713.80 220.00 2 16'09"00 T02 COMN 10.25/12 Pitch 1 -Ply 1 731.79 201.00 2 713.80 249.00 2 16'09"00 T03 COMN 10.25/12 Pitch 1 -Ply 1 731.79 184.00 2 713.80 301.00 2 16'09"00 T04 COMN 10.25/12 Pitch 1 -Ply 1 731.79 181.00 2 713.80 335.00 2 16'09"00 T05 COMN 10.25/12 Pitch 1 -Ply 1 731.79 194.00 2 713.80 273.00 Page 2 of 4 Job#76238 BEARING INFORMATION QTY SPAN DESCRIPTION 1 BRG# REACTION UPLIFT 2 16'09"00 TO6 COMN 10.25/12 Pitch 1 -Ply 1 731.79 143.00 2 713.80 217.00 6 21'05"00 107 COMN 10.25/12 Pitch 1 -Ply 1 900.14 193.00 2 888.37 223.00 1 21'05"00 T08 COMN 0.00/12 Pitch 1 -Ply 1 868.39 194.00 2 896.08 227.00 1 21'05"00 109 COMN 0.00/12 Pitch 1 -Ply 1 869.91 244.00 2 894.55 227.00 1 21'05"00 T10 COMN 0.00/12 Pitch 1 -Ply 1 875.61 193.00 2 895.87 227.00 2 12'08"00 T11 COMN 9.00/12 Pitch 1 -Ply 1 2746.89 1098.00 2 2255.90 867.00 4 12'08'00 T12 COMN 9.00/12 Pitch 1 -Ply 1 691.24 323.00 2 538.28 230.00 1 06'00"00 113 COMN 9.00/12 Pitch 1 -Ply 1 1744.99 423.00 2 1534.77 421.00 1 06'00'00 T14 COMN 9.00/12 Pitch 1 -Ply 1 332.92 97.00 2 332.92 97.00 5 36'06"00 T15 ATIC 10.25/12 Pitch 1 -Ply 1 1074.95 245.00 2 1462.81 194.00 3 1026.36 244.00 5 36'06"00 T16 ATIC 10.25/12 Pitch 1 -Ply 1 1075.41 244.00 2 1463.06 193.00 3 1025.65 243.00 14 24'00"00 T17 ATIC 9.00/12 Pitch 1 -Ply 1 1823.92 349.00 2 1823.92 349.00 2 19'06"00 T18 COMN 9.00/12 Pitch 1 -Ply 1 977.10 124.00 2 977.09 123.00 1 19'06"00 T19 COMN 9.00/12 Pitch 2-Ply 1 4780.15 1376.00 2 7147.09 1766.00 1 18'04'00 T20 COMN 10.25/12 Pitch 1 -Ply 1 936.16 190.00 2 955.97 311.00 1 18'04"00 T21 COMN 10.25/12 Pitch 1 -Ply 1 1852.07 603.00 2 2089.70 640.00 1 18'06"08 T22 COMN 10.25/12 Pitch 1 -Ply 1 1217.99 512.00 2 1289.24 559.00 1 18'06"00 T23 COMN 10.25/12 Pitch 1 -Ply 1 1820.64 641.00 2 1804.40 634.00 5 16'08"00 T24 COMN 9.00/12 Pitch 1 -Ply 1 984.15 267.00 2 985.44 267.00 2 13'08"00 T25 COMN 9.00/12 Pitch 1 -Ply 1 732.83 227.00 2 732.83 227.00 2 12'09'00 T26 COMN 9.00/12 Pitch 1 -Ply 1 541.87 165.00 2 541.87 165.00 3 05'03"11 T29 COMN 9.00/12 Pitch 1 -Ply 1 391.91 116.00 2 391.91 116.00 4 17'08'00 T30 COMN 9.00/12 Pitch 1 -Ply 1 750.83 309.00 2 750.83 309.00 2 1701"08 T31 COMN 9.00/12 Pitch 1 -Ply 1 727.21 299.00 2 728.42 297.00 Page 3 of 4 Job#76238 BEARING INFORMATION QTY SPAN DESCRIPTION BRG# REACTION UPLIFT 2 16'11"08 T32 COMN 9.00/12 Pitch 1 -Ply 1 674.38 205.00 2 680.34 226.00 2 16'11"08 T33 COMN 0.00/12 Pitch 1 -Ply 1 720.73 315.00 2 720.73 314.00 1 16'11"08 T34 COMN 0.00/12 Pitch 1 -Ply 1 720.73 268.00 2 720.73 265.00 1 12'08'00 T35 COMN 9.00/12 Pitch 2-Ply 1 2816.38 1311.00 2 2816.45 1311.00 1 18'06"00 T36 MONO 10.25/12 Pitch 1 -Ply 1 798.23 249.00 2 798.23 249.00 WOODFLOOR QTY SPAN DESCRIPTION BRG# REACTION UPLIFT 17 23'11"00 F01 SY42 0.00/12 Pitch 1 -Ply 1 1027.22 0.00 2 1027.22 0.00 3 09'05"12 F02 SY42 0.00/12 Pitch 1 -Ply 1 405.17 0.00 2 402.72 0.00 1 04'01"00 F03 SY42 0.00/12 Pitch 1 -Ply 1 580.00 0.00 2 725.16 0.00 1 07'10"00 FGE01 SY42GABL 0.00/12 Pitch 1 -Ply 1 660.56 0.00 1 09'02'04 FGE02 SY42GABL 0.00/12 Pitch 1 -Ply 1 777.89 0.00 1 14'04"12 FGE03 SY42GABL 0.00/12 Pitch 1 -Ply 1 1229.33 0.00 Total of Trusses 205 Maximun Height 11'10"00 Page 4 of 4 1. PERMANENT BRACING IS ALWAYS REQUIRED AND MUST BE PROVIDED BY THE BUILDING DESIGNER OR ENGINEER OF RECORD. PERMANENT BRACING INCLUDES TOP CHORD BRACING, BOTTOM CHORD BRACING, COMPRESSION WEB MEMBER BRACING AND GABLE END LATERAL BRACING. 2. RECIEPT, STORAGE, ERECTION, FIELD INSTALLATION AND FIELD ASSEMBLY IS THE RESPONSIBILITY OF THE CONTRACTOR. IN THE ABSENCE OF SPECIFIC BRACING REQUIREMENTS, THE CONTRACTOR SHALL ENSURE THAT THE TRUSSES ARE BRACED IN ACCORDANCE WITH BCSI-03. 3. NEVER EXCEED THE DESIGN LOADING SHOWN AND NEVER STACK MATERIALS ON INADEQUATELY BRACED TRUSSES. 4. PROVIDE COPIES OF THE TRUSS DESIGN TO THE BUILDING DESIGNER, ERECTION SUPERVISOR, PROPERTY OWNER AND ALL OTHER INTERESTED PARTIES. 5. TOP CHORDS MUST BE SHEATHED OR PURLINS PROVIDED AT SPACING SHOWN ON DESIGN. BUILDING DESIGNER OR ENGINEER OF RECORD REQUIRED TO PROVIDE THIS - SEE NOTE 1 ABOVE. 6. BOTTOM CHORDS REQUIRE RIGID CEILING OR CONTINUOUS LATERAL BRACING AT SPACING NOTED ON TRUSS PROFILE. BUILDING DESIGNER OR ENGINEER OF RECORD REQUIRED TO PROVIDE THIS - SEE NOTE 1 ABOVE. 7. TRUSS TO TOP PLATE AND ALL OTHER CONNECTIONS NOT SHOWN ARE THE RESPONSIBILITY OF THE BUILDING DESIGNER. 8. DO NOT CUT OR ALTER TRUSS MEMEBER OR PLATE WITHOUT PRIOR APPROVAL OF A PROFESSIONAL ENGINEER. FOR TRUSS REPAIR DRAWINGS, FAX REPAIR REQUEST TO 992-8700. FAX SHOULD CONTAIN TRUSS JOB NUMBER, TRUSS NUMBER, SPECIFIC SCOPE OF REPAIR AND CONTRACTOR CONTACT INFO. 3 SYMBOL INDICATES REQUIRED LATERAL BRACING. PERMANENT SYMBOL AND TEXT INDICATES INDICATES LOCATION WHERE 4 x 5 LATERAL BRACING IS THE REQUIRED SIZE AND LOACTION OF RESPONSIBILITY OF THE BUILDING BEARINGS(SUPPORTS)OCCUR. TRUSS PLATE. PLATE TEETH MUST =21111, DESIGNER. ALL BEARINGS ARE CONSIDERED BE FULLY EMBEDDED INTO ' TO BE NO 2 SYP(UNO). LUMBER AND PLATES MAY NOT BE CUT OR ALTERED. GENERAL NOTES 3x8 AND DETAILS 2 x 4 4 x 5 ` 'eV\ 8-11-15 I TS(� TR ETR DIMINSIONS ARE SHOWN IN FEET-INCHES-SIXTEENTHS. 1�VALDIVISION �V I►)►) enElEHOUSE) APEX APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-964 821 5200 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. - GABLE TRUSS WEB 2x6 NO 2 SYP "L" BRACE GABLE TRUSS WEB 2x6 NO 2 SYP "T" BRACE _ • FASTENED TO GABLE WEB . FASTENED TO GABLE WEB W/.131" x 22" AT 6" O.C. -1 W/.131" x 22" AT 6" O.C. SECTION A-A SECTION A-A OPTION 1 OPTION 2 (9' 8" - 12' 0") (9' 8" - 12' 0") 2x4 NO 2 SYP "L" BRACE GABLE TRUSS WEB FASTENED TO GABLE WEB GABLE TRUSS WEB 2x4 NO 2 SYP "T" BRACE o/ >� W/.131" x 22" AT 6" O.C. FASTENED TO GABLE WEB j / W/.131" x2 " AT6" O.C. r a: SECTION B-B SECTION B-B OPTION 2 OPTION 2 Cr) (3' 8" - 9' 7") (3' 8" - 9' 7") * VERTICAL WEBS 3' 8" OR CONNECTION BETWEEN BOTTOM CHORD OF LESS DO NOT REQUIRE GABLE END TRUSS AND WALL, AS WELL AS THE o GABLE BRACES DESIGN AND SPECIFICATION OF PERMANENT _ - ' BRACING OF THE ROOF SYSTEM IS THE % GABLE END BRACING \ RESPONSIBILITY OF THE BUILDING DESIGNER. DETAIL A ; ' ` ` y - o) co B ; B 63* i / i TRUETRUSS \\\\\\\\\\\\\\\\\ -\\\\\\\\\\\\\ A DIVISION OF F �T�tUEHOUSE APEX CONTINUOUS BEARING UNLESS NOTED OTHERWISE APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-904.821.5200 TECHNOLOGY THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. (3).148" x 3" TOE-NAILS @ TOP & BOTTOM CHORD CONNECTION. (NAILS THROUGH t BACK SIDE OF GIRDER INTO END GRAIN OF JACK TRUSS ARE NOT ALLOWED) JACK JACK (3).148" x 3" TOE-NAILS @ TOP & BOTTOM CHORD CONNECTION FOR CORNER JACK. SOME CORNER JACKS MAY REQUIRE z SIMPSON LS30 IN LIEU OF TOE-NAILS. JACK REFER TO SHOP DRAWINGS. ri f-- z w O w_ / '7\ JACK Q J Cl d o O p -( 2).148" x 3" TOE-NAILS @ TOP & BOTTOM c w Oz :.,,--- JACK CHORD CONNECTION. w_ CC Y Y U U U Q Q Q TYPICAL HIP SET NAILING DETAIL "HJ" GIRDER / VARIES ii ,Oirl\/ TRUElR sJ A OMUUON OR ApEx i 'APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-904 821 5200 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. i 'IGGYBACK TRUSS 6"x 8"x i"PLYWOOD(or 4'OSB)GUSSET APPLIED TO EACH FACE SPACD 48"O.C. to FASTEN WITH (4)8d COMMON INTO EACH CHORD FROM EACH SIDE(TOTAL 16 NAILS). MAXIMUM PURLIN SPACING 36"O.C. REFER TO INDIVIDUAL BASE TRUSS DESIGN FOR ACTUAL TOP CHORD PURLIN SPACING. 0 t 1 0 ... M PIGGYBACK TRUSS ‘ , ' \—ATTACH PURLIN TO TOP CHORD OF BASE TRUSS EACH BASE TRUSS WITH (2).131"x 2i" \\ OPTION 1 N MAXIMUM PURLIN SPACING 24"O.C. TO G?kq REFER TO INDIVIDUAL BASE TRUSS DESIGN (��,�/q NO FOR ACTUAL TOP CHORD PURLIN SPACING. ce11'!3SOyjS S � S S U ' 0(11 .:•.;`A`0.� O C \--‘ Al 0 •••1��i PIGGYBACK TRUSS CONNECTION DETAIL ATTACH PIGGY BACK TO EACH PURLIN FOR PIGGY BACK TRUSSES WITH SPANS LESS THAN 12'SCAB BASE TRUSS WITH (2).131"x 23" MAY BE OMMITED PROVIDED THAT THE ROOF SHEATHING IS ATTACH PURLIN TO TOP CHORD OF * CONTINUOUS OVER JOINT(SHEATHING TO OVERLAP A MINIMUM EACH BASE TRUSS WITH(2).131"x 23" OF 12"OVER JOINT). 1 UE'! (IJSS A U NNON OF OPTION 2 enuEHousp) APEX . . 'APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT.STE.402 JACKSONVILLE,FL 32224-904.821.5200 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. 36" MAXIMUM FLAT TOP CHORD SPAN FASTEN SCABS TO CONTINUOUS 2x4 NO 2 SYP RIDGE BEAM W/(2).131"x 22" OR 2X� 2x4 NO 2 SYP BLOCKING BETWEEN CAPS '11/Ar/JP�o2S V/ C rA FASTENED W/(2).131"x 22"AT EACH END 4'•'� �0M ,�/•73 SC•943. cFRP i°4 � , 4# OA, req F o--o to • (1) PURLIN AT MIDSPAN OF BASE TRUSS ACH TRUSS TOP CHORD WITH (2).131"x 24" / \ CONVENTIONAL FRAMED PIGGYBACK DETAIL ifV\ TR ETR S.7 A MINN OR TAPEX 'APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-904.821.5200 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. (2)16d TOP NAILS // PER STRAP TOP NAILS PER STRAP STRAP 1 I X \ \ \ \ / (1)16d FACE NAIL (1)16d FACE NAIL 1)1'ER STRAP STRAP V N \ \\ \ A (3)16d STRAIGHT (3)16d STRAIGHT \ AILS PER SIDE AILS PER SIDE i.e., / 1 1 N i . 1 / \ THA422 \ --- -DEPTH AND PLIES VARY THA422 FLOOR TRUSS TO BEAM FLOOR TRUSS TO ROOF GIRDER (2)16d TOP NAILS ER STRAP i>< NN (1)16d FACE NAIL ER STRAP \ \ (3)16d STRAIGHT \ THA422 CONNECTIONS / AILS PER SIDE -o , . A , iev\ _ ' VL Vss AMOM OP THA422 entUEHOUSE) TAPEX FLOOR TRUSS TO FLOOR TRUSS APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC..A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT.STE.402 JACKSONVILLE,FL 32224-904.821.5200 . THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. 24" TYP I I I I I k g X X X COMMON TRUSSES 1 @ 24" O.C. I 0 z z J MAX 12" OVERHANG UNLESS A___ WDESIGNED BY OTHERS :,s%---- 00 VALLEY SET Ga\ Cal a �i 24" O.C. OU _1\ � � . - LLC W � Io .;.// COMMON TRUSSES @ 24" O.C. O UOMMUN I KUSSES @ 2•5 U.C. PARTIAL TRUSS LAYOUT 2x4 NO 2 SYP NAILER ROOF SHEATHING OR PURLINS. FASTEN VALLEY ASTENED TO EACH COMMON IF DECKING IS NOT INSTALLED BELOW TRUSS TO NAILER TRUSS W/(2).131"x 2 VALLEY TRUSSES, PULINS MUST BE W/.131"x 22" INSTALLED FOR TOP CHORD BRACING. 6" O.C. SEE INDIVIDUAL TRUSS PROFILE FOR PURLIN AND SPACING. r�F 't p Noc° COP G FIELD BEVEL VALLEY �• SS TRUSS BOTTOM CHORD VALLEY TRUSS OTO MATCH COMMON TRUSS FRAMING DETAIL •‘‘' FASTEN VALLEY TRUSS PITCH TO EACH COMMON TRUSS W/(2).131"x22" ROOF SHEATHING j' GNORO TR TC T S " ��SS�OP A MINION O! 10 eTRUEHOUS4 APEX •. •.0, -APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC..A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-904 821 5200 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2x6 "STRONGBACKS" SHOULD BE LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. STRONGBACK MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD. SECURELY FASTEN TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW. X V ►! _ 1 Y USE SIMPSON ATTACH TO VERTICAL ATTACH TO VERTICAL ATTACH 2x4 VERTICAL TO FACE H2.5 TO ATTACH WEB WITH (3)12. WEB WITH (3)12. •F TRUSS. FASTEN TO TOP 2x6 TO CHORD. COMMON WIRE NAILS. COMMON WIRE NAILS. AND BOTTOM CHORD WITH (2)12d COMMON IN EACH CHORD. = XV N t-- Y r Y R R ,‹ RR\ ,< 5Z SZ R :\:\.\\.\\.\: <.\\,\\\\, �\.\ �,\\\\, 7BLOCKING s g g s gg g s § \ TRUSSES TYPICAL SPLICE 48" 2x6 AS REQUIRED FLOOR TRUSS --SEARING WALL STRONG BACKS THE STRONGBACKS SHOULD EITHER BE SECURED TO ADJACENT PARTITION WALLS OR ALTERNATE"X" BRIDGING SHOULD BE USED TO TERMINATE THE BRACING MEMBERS. IF SPLICING IS NECESSARY, USE A 4'-0" LONG SCAB CENTERED OVER THE SPLICE AND JOIN WITH (12)12d NAILS EQUALLY SPACED. iAl ALTERNATE METHOD OF SPLICING: TRi JSs OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4'-0"AND FASTEN WITH (12)12d COMMON WIRE NAILS •_MNION OR STAGGERED AND EQUALLY SPACED. (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A �, _ ?ACP PE VERTICAL) UJFJ \- A' i 'APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.. A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-904 821 5200 I THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY. 76238 Ply: 1 SEAN:17605/T76/SY42 Custom-Roick Res,, Qry: 17 FROM: DRW: F01 Wgt:130.2 lbs ... / ... 07/19/2018 13'1'81 2311" 13'1'8 3' 10'6" 1—2'6"—H 3. (TYP) I I I.2'6'12.--2'6.12—{--2'6'12--I--2'6'12--I I—2'6.12 + 2'6"12--}—2'6'12--{ =4X8 =3X4 W=3X4 -3X3 m3X4 =4X8 VA B C D E F G H I J K LM io 1 (1)8'1"2 tfill T S R Q P 0 -- =3X8 =4X8 =4X5 =3X3 W=H0310 =4X8 =3X8 1 2311" .i Loading Criteriast) Wind Criteria Snow Criteria( fin PS F) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA T Na PP DefI rtinn in Inr dell L/# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.383 G 1732 480 J I U 1027 /- /- /- /- /6.0 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.865 G 450 360 N 1027 /- /- /- /- /6.0 BCDL: 10.00 Category:NA Snow Duration:NA nvnc.lt_y. v.v,n D - - U Min Brg Width Req= 1.5 Des Ld: 65.004, EXP:NA HORZ(TL): 0.092 B - - N Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Bearings U&N Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.630 Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.764 Maximum Top Chord Forces Per Ply(lbs) Spacing:16.0"J MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.649 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 1 0 G-H 0 -3817 I:NA GCpi:NA Plate Type(s): B-C 0 -2649 H-I 0 -3811 Wind Duration:NA WAVE,HS VIEW Ver:18.01.00B.0430.21 ,C-D 0 -2649 I-J 0 -2648 Lumber End Vertical Attachment D-E 0 3817 J-K 0 2648 Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical F- 0 -3817 K-L 1 0 G F-G Top chord 4x2 SP#2 using(3)qty.10d box or(0.128"x3"min)gun nails,or 0 3817 Bot chord 4x2 SP#1 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Maximum Bot Chord Forces Per Ply(lbs) Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values narrow face. approved 1/30/2013 by ALSC U-T 1481 0 0-P 3394 0 Additional Notes T-S 3392 0 P-O 3394 0 Plating Notes +2x6 continuous strongback.See detail S-R 3819 0 0-N 1480 0 All plates are 1.5X3 except as noted. STRBRIBR1014 for bracing and bridging R-Q 3817 0 recommendations. Purlins Truss must be installed as shown with top chord up. Maximum Web Forces Per Ply(lbs) In lieu of structural panels or rigid ceiling use purlins The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) 1-8-0. V-U 0 -9 G-R 0 -72 TC 24 0.25 23.67 A-U 0 -77 H-Q 0 -141 BC 120 0.25 23.67 U-B 0 -1740 Q-I 489 0 Apply purlins to any chords above or below fillers B-T 1364 0 I-O 0 -871 at 24"OC unless shown otherwise above. C-T 0 -179 J-O 0 -179 Loading T-D 0 -867 O-K 1363 0 D-S 496 0 K-N 0 -1739 Bottom chord checked for 10.00 psf non-concurrent F-S 0 -194 L-N 0 -77 live load. S-G 3 -3 N-M 0 -9 Camber Max JT VERT DEFL:LL:0.38"DL:0.48".See detail DEFLCAMB1014 for camber recommendations. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Irv') 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer ,*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE No l 08391oweki PE Nameson Derek.58544 No 71457y Adam K PE No.7769311 APEX 76238 Ply:1 SEQN:17606/T36/SY42 Custom-Roick Res. Qty: 3 FROM: DRW: F02 Wgt:58.8 lbs ... / ... 07/19/2018 5'4"86'4"12 9'5"12 I I- 5'4"8 1'0"4 3'1" r'{- 2'6' _I- 2'6°12 -{ I_2'6°12-{5-{ (TYP) 3X3 1111.X3 =3X3 III1 5X3 III 1 5X1 1114X (R T e L , U , 3 �::: Zo Mk _ K =3X3=3X4 11115X3 3X, 9'5"12 A Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.047 C 999 480 K 405 /- /- /- /- /6.0 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.115 C 999 360 F 403 /- /- /- /- /3.5 BCDL: 10.00 Category:NA Snow Duration:NA HORZ(LL): 0.010 B - - K Min Brg Width Req= 1.5 Des Ld: 65.00 EXP:NA HORZ(TL): 0.019 B - - F Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Bearing F is a rigid surface. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.746 Bearing K Fcperp=565psi. Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.386 Spacing:16.0" MW FRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.306 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. I:NA GCpi:NA Plate Type(s): A-B 1 0 D-E 0 -537 Wind Duration:NA WAVE VIEW Ver:18.01.008.0430.21 B-C 0 -568 E-F 0 -557 Lumber C-D 0 -568 F-G 0 0 Value Set:13B(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Top chord 4x2 SP#2 Bot chord 4x2 SP#2 Chords Tens.Comp. Chords Tens. Comp. Webs4x2SP#3 K-J 475 0 I-H 0 -1 Lumber value set"13B"uses design values J-I 568 0 approved 1/30/2013 by ALSC Purlins Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: L-K 0 -9 J-C 51 -18 Chord Spacing(in oc) Start(ft) End(ft) A-K 0 -73 D-I 0 -280 TC 24 0.25 9.48 K-B 0 -559 I-F 642 0 BC 107 0.25 9.15 B-J 170 0 F-H 25 0 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. End Vertical Attachment Attach notched end vertical(s)to next end vertical using(3)qty.10d box or(0.128"x3"min)gun nails,or (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire staples,through wide face;or(3)qty.16-Gauge,1" Crown(minimum),1-1/2"length wire staples on each narrow face. Additional Notes Truss must be installed as shown with top chord up. The overall height of this truss excluding overhang is 1-8-0. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if /\ APEX 1rueHouse PE No.l 0 391owski JPeffrey 58544 on PE No. Murray7457APE No.Russell 76238 Ply:1 SEQN:17607/T41/SY42 Custom-Roick Res. a Qty: 1 FROM: DRW: F03 Ar Wgt:32.2 lbs ... / ... 07/19/2018 1'7"82'5'8 4'1" L. 178 I 10" I 178 -I F�1'3"--I F3'i (TYP) F3" III 1.5X3 =3X3 =tj(3 III 1D5X3 T I J :A .: B i 76238 Ply:3 SEQN: 17680/T8/COMN Custom-Roick Res. Qty: 1 FROM: DRW: FG01 Wgt:627.9 lbs ... / ... 07/19/2018 4'3'10 36'6" "�7~103 L'L_ 6'8"9 9'5'8 12'5"5 15'6"3 18'4"4 20'7"15 23'1"5 25'6'12 29'0"5 32'0'1 350'9 i-16"71 12'4"15 I 2'8'15 1 2'11"13 1 3'0'13 1 2'10"1 I 2'3'11 I 2'5"7 1 2'5'7 3'S"9 1 2'11'13 ( 3'0'8 12 10.25 F" 06X8(") ..4X8 .5X7(") 'a 4X8 5X7 w6X8(") .4X10 w-4X4 m4X5 016X8('-) T /ABB C D E F G H T3 'I J K L M N ml �z �3X4(A1)%/L� � � �lig re Y 'W 0=3X4(A1) 1 10'1.2 AB AA Z Y X w r=6X10 =6X8 T S Fl O P 54X5 ..4X8 ...8X8(**) J 82 =5x7 '•H0510 8X8(") w3X8 A 18'4.4 j 18'1'12 j 1'7'3 2'6'11 287 2'10"1 3'0"13 3'2"1 2'7'11 2'4"15 2'11'3 2'11'13 3'0'5 2'6'12.) ~� 2415 T 6'6'13 1 9'3"4 1 12'1"5 1 15'2'3 1 18'4'4 1 20'11'151 23'4"131 26'4' I 29'3'13 1 32'4'1 I 34'10'13' 173 Loading Criteria st) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.004/ Speed: 130 mph Pf:NA Ce:NAVERT(LL): 0.132 S 999 480 A 2036 74 /- /- /- /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA AI VERT(TL): 0.362 S 875 360 V 7975 1307 /- /- /- /4.5 BCDL: 10.0041 Risk Category:II Snow Duration:NA HORZ(LL): 0.025 J - - 0 2029 476 /- /- /- /6.5 Des Ld: 65.00 J EXP:D - HORZ(TL): 0.047 J - - vvtnu react ns based on MWFRS NCBCLL:0.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.983 V Min Brg Width Req= 2.9 Load Duration: 1.00 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.759 0 Min Brg Width Req= 1.5 MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI: 0.732 Bearings A,V.&0 Fcperp=565psi. Spacing:16.0" C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE,HS VIEW Ver:18.01.00B.0430.21 Lumber Plating Notes A-B 30 -938 H-I 3874 -606 B-C 35 -1776 I-J 1292 -85 Value Set:13B(Effective 6/1/2013) All plates are 3X4 except as noted. C-D 55 -2344 J-K 484 -1456 Top chord 2x4 SP#2:T3 2x4 SP#1: (")6 plate(s)require special positioning.Refer to D-E 56 -2386 K-L 969 -3896 Bot chord 2x6 SP#2:B2 2x6 SP SS Dense: scaled plate plot details for special positioning E-F 0 -487 L-M 726 -2971 Webs 2x4 SP#3:W5 2x10 SP#2: requirements. F-G 1727 -392 M-N 443 -1847 Lumber value set'13B"uses design values Plate positions consider a 0.50 inch truss perimeter G-H 3874 -606 N-0 223 -942 approved 1/30/2013 by ALSC edge distance. Nailnote Purlins Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Nail Schedule:0.131"x3",min.nails In lieu of structural panels or rigid ceiling use purlins Top Chord:1 Row @ 3.50"o.c. to laterally brace chords as follows: A-AB 693 -21 V-U 130 -1579 Bot Chord:1 Row @ 8.75"o.c. Chord Spacing(in oc) Start(ft) End(ft) AB-AA 695 -21 U-T 1145 -422 Webs :1 Row @ 4"o.c. TC 24 0.00 36.50 AA-Z 1890 -38 T-S 3276 -848 Repeat nailing as each layer is applied.Use equal BC 120 0.15 36.35 Z-Y 2386 -56 S-R 3081 -755 spacing between rows and stagger nails in each row Apply purlins to any chords above or below fillers Y-X 2377 57 R-Q 1969 -474 to avoid splitting. at 24' OC unless shown otherwise above. X-W 284 0 0 P 699 165 4"o.c.spacing of nails perpendicular and parallel to W-V 409 -1915 P-0 697 165 grain required in area over bearings greater than 4" Additional Notes Special Loads The overall height of this truss excluding overhang is 1-8-0. Maximum Web Forces Per Ply(lbs) (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) Webs Tens.Comp. Webs Tens. Comp. TC:From 80 plf at 0.00 to 80 plf at 3.67 TC:From 215 plf at 3.67 to 215 plf at 4.73 B-AB 14 0 V-I 546 -2631 TC:From 446 plf at 4.73 to 446 plf at 8.27 B-AA 1207 -16 I-U 1305 -265 TC:From 215 plf at 8.27 to 215 plf at 9.88 AA-C 11 -518 U-J 575 -2839 TC:From 80 plf at 9.88 to 80 plf at 36.50 C-Z 523 -20 J-T 1413 -282 BC:From 13 plf at 0.00 to 13 plf at 36.50 Z-D 12 -378 T-K 425 -2121 TC: 144 lb Conc.Load at 3.92 Y-E 82 -26 K-S 1208 -236 TC:1840 lb Conc.Load at 9.27 E-X 193 -2090 S-L 904 -238 BC:5005 lb Conc.Load at 25.95 X-F 920 -80 L-R 132 500 Wind F-W 230 -2224 R-M 1111 -280 W-G 853 -75 M-Q 141 -555 Wind loads and reactions based on MWFRS. G-V 216 -2147 Q-N 1264 -306 H-V 33 -160 P-N 17 0 NOTES: It 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 /fV\ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX TrueHouse FENo 60839 PE No 58544 PE No.71457 PE No.77693 76238 Ply: 1 SEAN: 17663/T14/SPEC ' Custom-Roick Res.* Qty: 9 FROM: DRW: FG02 Wgt:105.0 lbs / .. 07/19/2018 L 1'5"7 I 3'11"15 I 6'2"14 I 8'7"10 ' 1121 I 13'5"1 I 15'9"12 I 18'6" f 15„7 2,6"8 2,3" 2,4"12 2,6"8 2,3„ 2,4"12 2'8"4 12 ;06X10(") 1113X4 =3X4 =5X5(") 1113X4 =4X4 -4X4 10.25 V B C D E F G H -6X6.' I ri 4X5(..) -_,._.;.:1- I �� T ryl// + 101 2 5'2 J Ir L 1111 Q P O N M L B2 K J T 1113X4 =6X10(") =3X4 1113X4 5X7(") =4X4 =4X8 1114X5(") i 18'6" -i 17"3 I 24"12 I 2'6"8 , 23" I 2'6"8 I 2'4"12 I 2'5"4 ,- 2'4"4 , 1'7"3 3'11"15 6'6"6 8'9"6 11'3"13 13'8"9 16'1"12 18'6" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in Ioc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.174 N 999 480 A 1125 /171 /603 /- /34 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA JVERT(TL): 0.492 N 662 360 J 920 /176 /382 /- /- /4.0 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.034 B - - Wind reactions based on MWFRS Des Ld: 65.00 EXP:D HORZ(TL): 0.066 B - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 J Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.635 Bearings A&J Fcperp=565psi. Load Duration:1.00 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.989 Spacing:16.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.833 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 289 -1439 E-F 715 -3172 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 514 -2566 F-G 707 -3141 Lumber Additional Notes C-D 514 -2565 G H 557 -2382 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is D-E 673 -3140 H-I 336 -1398 Top chord 2x4 SP#2 1-8-0. Bot chord 2x4 SP#1 :B2 2x4 SP#2: Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values A-Q 1026 -231 N-M 3172 -715 approved 1/30/2013 by ALSC Q-P 1021 -228 M-L 2498 -584 P-O 3115 -667 L-K 1561 -380 Special Loads O-N 3180 -718 K-J 9 -2 (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) TC:From 80 plf at 0.00 to 80 plf at 18.50 Maximum Web Forces Per Ply(lbs) BC:From 13 plf at 0.00 to 13 plf at 18.50 Webs Tens.Comp. Webs Tens. Comp. TC: 325 lb Conc.Load at 3.92 B-Q 23 -47 F-M 79 -289 Plating Notes B-P 1749 -324 M-G 769 -152 (")7 plate(s)require special positioning.Refer to C-P 72 -476 G-L 138 -560 scaled plate plot details for special positioning P-D 291 -646 L-H 981 -220 requirements. D-O 119 -111 H-K 209 -783 Plate positions consider a 0.50 inch truss perimeter 0-E 267 -88 K-I 1603 -385 edge distance. E-N 26 -81 I-J 232 -896 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 18.50 BC 99 0.15 18.50 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 111- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (16."11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi"\ APEX TrueHouse PE No l O839lowskirey P No 58544 Arneson PEPE No.71457y APE No.7 69311 - 76238 Ply:3 SEQN:17689/T11/COMN Custom-Roick Res. Qty: 1 FROM: DRW: FG03/ Wgt:581.7 lbs ... / ... 07/19/2018 467 II 1'S"7 3'1"F. 73"15 9'11'12 12'11"8 15'8"8 18'4'4 207'12 232" 257'12 28'2'8 30'5" 332" 1'5'7 I- 278 I 2712 -I 211'12 I2'9" -I 2'7'12 I 2'3"8 I 26"4 I 2512 I- 2'6"12 I 2.2"8 I 27 1 12 7 /6X8("") w4X4 .4X4 113X40 w5X7(") 1113X4 m5X7(") m4X5 =3X8 10.25 B C D 6T2 F G H I J K L M N TT 3X4(A1)A -3.... ..p....,,....._------...„..4r...---,.........„17r.--- / W6 ,i 72 10'1"2 AA B1_Z Y X W v nU T S R 0 P AB 113X4 3X8 =8X8(") =4X4 114X5 =6X10 4' =8X8(") =5X5 =6X8 =3X8 113X8 1 18'4'4 1 14'912 A I~"I I 2'10" I 2'9'8 I 2'11"4 I 2'7'4 1 2'11'12 1 27'8 I 2'5'12 I 2'9"8 I 2'3'8 I 23" I 2'4'8 1'7'31 2'7"4 I 7'0'7 9'10' 12'9"4 15'4'8 18'4"4 20'11"12 23'5"8 26'3" 28'6'8 30'9"8 337 4'2"7 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# . L°�U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.143 E 999 480 A 2093 '105 /- /- /- /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA .✓VERT(TL): 0.392 E 817 360 U 6522 '1050 /- /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.024 B - - AB 2465 '563 /- /- /- /6.5 Des Ld: 65.00 J EXP:D HORZ(TL): 0.046 B - - v.'.'cautions based on MWFRS NCBCLL:0.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.929 U Min Brg Width Req= 2.4 Load Duration:1.00 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.745 AB Min Brg Width Req= 1.5 MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI: 0.737 Bearings A,U,&AB Fcperp=565psi. Spacing:16.0" C&C Dist a:3.32 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 Chords Tens.Comp. Chords Tens. Comp. Lumber Plating Notes A-B 45 977 H-I 2387 375 B-C 64 -1900 I-J 294 0 Value Set:13B(Effective 6/1/2013) All plates are 4X8 except as noted. C-D 86 -2722 J-K 507 -1903 Top chord 2x4 SP#2:T2 2x4 SP#1: (")5 plate(s)require special positioning.Refer to D-E 31 -1555 K-L 871 -3711 Bot chord 2x6 SP SS Dense:B1 2x6 SP#2: scaled plate plot details for special positioning E-F 35 -1589 L-M 605 -2603 Webs 2x4 SP#3:W4 2x8 SP#1: requirements. F-G 834 -233 M-N 320 -1388 :W6 2x6 SP#2: Plate positions consider a 0.50 inch truss perimeter G-H 2387 -375 Lumber value set"13B"uses design values edge distance. approved 1/30/2013 by ALSO Purlins Maximum Bot Chord Forces Per Ply(lbs) Nailnote Chords Tens.Comp. Chords Tens. Comp. In lieu of structural panels or rigid ceiling use purlins Nail Schedule:0.131"x3",min.nails to laterally brace chords as follows: A-AA 725 -33 U-T 3 -522 Top Chord:1 Row @ 4.00"o.c. Chord Spacing(in oc) Start(ft) End(ft) AA-Z 728 -32 T-S 1661 -459 Bot Chord:1 Row @ 8.25"o.c. TC 24 0.00 33.17 Z-Y 2033 -69 S-R 3334 -796 Webs :1 Row @ 4"o.c. BC 120 0.15 33.17 Y-X 2722 -85 R-Q 2761 -643 Repeat nailing as each layer is applied.Use equal Apply purlins to any chords above or below fillers X-W 1589 35 Q P 1558 -360 spacing between rows and stagger nails in each row at 24' OC unless shown otherwise above. W-V 1483 28 P-0 22 5 to avoid splitting. 4"o.c.spacing of nails perpendicular and parallel to Additional Notes V-U 246 -998 grain required in area over bearings greater than 4" The overall height of this truss excluding overhang is Special Loads 1-8-0. Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) B-AA 27 0 U-I 446 -2132 TC:From 80 plf at 0.00 to 80 plf at 3.67 TC:From 215 plf at 3.67 to 215 plf at 4.73 B-Z 1287 -35 I-T 1034 -210 TC:From 395 plf at 4.73 to 395 plf at 8.27 Z-C 22 -602 T-J 462 -2271 TC:From 215 plf at 8.27 to 215 plf at 9.88 C-Y 776 -42 J-S 1099 -220 TC:From 80 plf at 9.88 to 80 plf at 33.17 Y-D 3 -17 S-K 336 -1661 BC:From 13 plf at 0.00 to 13 plf at 33.17 D-X 90 -1313 K-R 890 -175 TC: 144 lb Conc.Load at 3.92 X-E 41 -303 R-L 1138 -272 TC: 1512 Ib Conc.Load at 9.27 W-F 940 71 L-Q 173 -717 BC:4864 lb Conc.Load at 25.95 F-V 234 -2608 Q-M 1253 -294 Wind V-G 746 -58 M-P 183 -770 Wind loads and reactions based on MWFRS. G-U 144 -1546 P-N 1548 356 H-U 30 -150 N-O 179 -773 NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11."11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi"\ APEX TrueHouse PEi No.l 0 391owski PErey No. 8544son PE No.71457y APE No.Russell 76238 Ply:1 SEQN:17695/T64/COMN Custom-Roick Res. Qty: 3 FROM: DRW: FG04 4 Wgt:220.5 lbs ... / ... 07/19/2018 4'3"9 -I 1,5"7 2'10'1 1...._.1'5"7 61114 9'11'12 12'10"5 15'8"7 18'6" 21'0"8 23'2'4 25'7'4 27'10"8 30'3"8 33'2' l'S"7I 2'8" 5 I 2'11.13 I 2'10'9 I 2'10"1 I 2'9"9 I 2'6"8 I 2'1'12 I 25" -I 2'3"4 Ti 2'5" I 2'10.8 12 10.25 •6x8(•") m8X8("") -4X8 =4X8 =8x12("") =4X10 -4X5 B C D E1111 F G H I J K L M a4X8N T1 =4x6(..)A Ig,��\ _, ..\ __\ _'�..'�1 �= �_ W7 m 72 •�_ - IN - - X10'1"2 AA Z Y X W V 82 U^4X8T S R 0 P O wi4X10 ==8X8(-) .4X8 J- =8X12('") =4X10 =4X5 14X8 11AB 4X5 1 18'4.4 1 14'9.12 'A 2'613 I 2'11"9 I 2'11'13 I 2'8"5 I 2'9"9 I 2101 I 25"8 I 2'3'8 I 2'10" ( 2'5" I 2'5"8 I 2'6'8 1L1 3'10"9 610"2 9'10" 12'6'5 15'3'15 18'2" 20'7"8 22'11° 25'9" 28'2' 30'7'8 332" 11'31'1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL): 0.120 D 999 480 A 1243 /169 /743 /- /24 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.385 D 910 364.1 2560 /404 /1268/- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.023 B - - AB 907 /124 /486 /- /- /6.5 Des Ld: 65.004 EXP:D HORZ(TL): 0.045 B - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.968 U Min Brg Width Req= 2.6 Load Duration: 1.00 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.966 AB Min Brg Width Req= 1.5 Spacing:16.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.909 Bearings A,U,&AB Fcperp=565psi. C&C Dist a:3.32 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 - -- Lumber Wind A-B 251 -1676 H-I 1171 -218 Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C B-C 444 -3259 I-J 233 -2542 memberdesign. C D 529 3359 J K 248 -2542 Top chord 2x6 SP#2 Ti: 2x4 SP#2: D-E 536 -3384 K-L 243 -2498 Bot chord 2x6 SP SS Dense:82 2x6 SP#2: E-F 325 -1838 L-M 321 -2702 Webs 2x4 SP#3:W2,W6 2x4 SP#2: Additional Notes :W7 2x6 SP#2: The overall height of this truss excluding overhang is F-G 753 -79 M-N 212 -1559 G-H 2726487 Lumber value set"13B"uses design values 1-8-0. approved 1/30/2013 by ALSO Maximum Bot Chord Forces Per Ply(lbs) Special Loads Chords Tens.Comp. Chords Tens. Comp. (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) A-AA 1257 -209 U-T 428 -2404 TC:From 80 plf at 0.00 to 80 plf at 33.17 AA-Z 1257 -210 T-S 373 -1015 BC:From 13 plf at 0.00 to 13 plf at 33.17 Z-Y 3439 -473 S-R 2542 -248 TC: 756 lb Conc.Load at 4.92 Y-X 3384 -536 R-Q 2774 -329 TC: 744 lb Conc.Load at 25.83 X-W 3346 -535 0-P 1736 -241 Plating Notes W-V 1682 -305 P-O 31 -6 All plates are 3X4 except as noted. V-U 89 -852 (")6 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs) scaled plate plot details for special positioning Webs Tens.Comp. Webs Tens. Comp. requirements. Plate positions consider a 0.50 inch truss perimeter AA-B 36 -3 H-T 1909 -292 edge distance. B-Z 2185 -266 T-I 200 -1258 Z-C 126 -908 I-S 2676 -363 Purlins C-Y 120 -688 S-J 121 -715 In lieu of structural panels or rigid ceiling use purlins Y-D 74 -205 K-R 40 -370 to laterally brace chords as follows: X-E 353 -20 R-L 133 -570 Chord Spacing(in oc) Start(ft) End(ft) E-W 243 -1816 L-Q 34 -306 TC 24 0.00 33.17 W-F 716 -88 Q-M 1111 -110 BC 49 0.15 33.17 Apply purlins to any chords above or below fillers F-V 357 -1929 M-P 122 -754 at 24"OC unless shown otherwise above. V-G 810 129 P-N 1688 228 G-U 454 -2267 N-O 143 -845 U-H 255 -1373 NOTES: Nr 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11."11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 /f*/\ TrueHouse MichaePE No 160 83G 609 PErNo. 8544 on Derek B PE No 71457y APE No.dam K Russell APEX 76238 Ply:1 SEQN:17721/T15/COMN Custom-Roick Res. Qty: 2 FROM: DRW: FG05 Wgt:224.7 lbs ... / ... 07/19/2018 4'3'9 F5'17~20"� 1I 611'14I9'11'12I 12'10"5I 15'87I 18'6' I27'7'17I 23'9'13I 26'3'8I 28'6"13I 30'9'11I 332" 115"7 2B5 211.13 2'10'9 2107 2'9"9 2'7"11 2'8'3 2'5.11 2'3'5 2'2'13 2'4'5 12 0 4X8 10.25 /6X8(") =8X8(") =4X8 T3 =Ht010(") =4X10 =4X4 =4X8 =6X8 T7 - B C D Eill F (I) H 1--6X8 J K L M N an ��44 a 4X8("")��`_ , `_� _ 4_ 4 .1_!�_ _„- ,W6 m ■■ 10'1"2 AA Z Y X W vg U^4X8- T S R a P O =4X10 =8X8(") =4X8 �_ =8X12("") =6X8 ?m4X10 =4X8 =6AB X8 1 18.4.4 A 14'9'12 i 2'6'13I 2'11'9 I 2'11'13 I 2'8"5 I 2'9'9 I 2'10'1 _I 2711 _I 2'6'11 I 2'6'3 I 2'4'5 I 2'2'5_I 2'8"73 11' 3'10'9 6'10'2 9'10' 12'6'5 15'3'15 18'2" 20'9'11 23'4'5 25'10'8 28'2'13 30'5'3 33'2' II-'3q1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Sid: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.107 K 999 480 A 1186 /162 /317 /- /24 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA 4/VERT(TL): 0.383 K 769 360,t 3243 /447 /857 /- /- /4.5 BCDL: 10.00 Risk Category:it Snow Duration:NA HORZ(LL): 0.019 B - - AB 1525 /140 /294 /- /- /6.5 Des Ld: 65.00 J EXP:D HORZ(TL): 0.042 B - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.747 U Min Brg Width Req= 3.5 Load Duration:1.00 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.975 AB Min Brg Width Req= 1.5 Spacing:16.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.976 Bearings A,U,&AB Fcperp=565psi. C&C Dist a:3.32 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE,HS VIEW Ver:18.01.00B.0430.21 Lumber Purlins A-B 263 -1605 H-I 1171 -250 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins C-D 576 -2 I-J 4 -5 to laterally brace chords as follows: C D 576 29998 98 J K 44 6 46 54400 0 Top chord 2x6 SP#2 Ti: 2x4 SP#2: Chord Spacing(in oc) Start(ft) End(ft) D-E 584 -3018 K-L 380 -4885 :T3 2x6 SP SS Dense: TC 24 0.00 33.17 E-F 660 -1282 L-M 241 -2922 Bot chord 2x6 SP SS Dense:B2 2x6 SP#2: Webs 2x4 SP#3:W4 2x4 SP#2: BC 38 0.15 33.17 F-G 1855 -151 M-N 4 -43 :W6 2x6 SP#2: Apply purlins to any chords above or below fillers G-H 4024 -534 at 24"OC unless shown otherwise above. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Wind Maximum Bot Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Special Loads Wind loads based on MWFRS with additional C&C member design. A-AA 1204 -218 U-T 472 -3558 (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) AA-Z 1202 -219 T-S 520 -970 TC:From 80 plf at 0.00 to 80 plf at 25.54 Additional Notes Z-Y 3246 -496 S-R 3475 -259 TC:From 215 plf at 25.54 to 215 plf at 29.08 The overall height of this truss excluding overhang is Y-X 3018 -584 R-Q 5665 -475 TC:From 80 plf at 29.08 to 80 plf at 33.17 1-8-0. X-W 2975 -584 Q-P 4758 -366 BC:From 13 plf at 0.00 to 13 plf at 33.17W-V 1107 -785 P-O 2647 227 TC: 756 lb Conc.Load at 4.92 TC:1099 lb Conc.Load at 26.15 V-U 178 -1970 TC: 223 lb Conc.Load at 27.02 TC: 145 lb Conc.Load at 28.83 Maximum Web Forces Per Ply(lbs) Plating Notes Webs Tens.Comp. Webs Tens. Comp. All plates are 3X4 except as noted. AA-B 42 0 H-T 3216 -372 (I)-plates so marked were sized using 0% B Z 2049 -272 T-I 203 1602 Fabrication Tolerance,0 degrees Rotational Z-C 135 -837 I-S 3178 342 Tolerance,and/or zero Positioning Tolerance. C Y 104 -628 S J 170 -1429 (")6 plate(s)require special positioning.Refer to X-D 68 25 J-R 2352 -211 scaled plate plot details for special positioning X-E 426 -25 R-K 126 1217 requirements. E-W 268 -2157 K-Q 112 -918 Plate positions consider a 0.50 inch truss perimeter W F 345 33 L 542 62 edge distance. F-V 363 2133 L L-P 147 -2162 V-G 882 -132 P-M 1174 -62 G-U 460 -2417 M-O 249 -2914 U-H 268 -1986 N-O 39 -134 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 /CV\ TrueHouse PE No Michael 0839Io `I FEJeffrey No.58544son PE No. MurrayDerek B7457Adam K PE No.7769311 APEX 76238 Ply:1 SEQN:17710/T81/COMN Custom-Roick Res. Qty: 4 FROM: DRW: FG06 J Wgt:193.9 lbs ... / ... 07/19/2018 4'3'9 1,5"7I 2'10'1 I 6'11"14 9'11'12 12'10'5 15'8'7 18'6' 20'11'8 23'2'4 25'9' 28'0'4 30'3'8 33'2' ~7I I 2'8"5 I 2'11'13 I 2'10'9 I 2'10"1 I 2'9'9 I 2'5"8 I 2'2'12 I 2'6'12 I 2'3'4 ( 2'3'4 I 2'10'8 12 10.25 /6X8("") .8X8(") r=3X8 =4X8 =8X8("") v4X4 B C D E F G H L4X8 J K L M =5X5N T1 �z -4X5(..)A W g3 W6 113I 10'1"2 AA Z 8 Y X W V U^ T S R O P PI =4X10 6X8(") =3X8 J=4X8.5X7("") =4X8 =4X8 ?=3X8 AB j 18'4'4 j 14'9'12 i 1, 3"11I 2'11.9 I 2'11'13 28'5 _I 29'9 I 210'1 I 25"8 _I_ 2'4'8 _I 2'7'4 _I 2'5" I 2'7'4 f 2'6'8 1 1'3"1 1..p1 .1.39 � 6'10'2 9'10' 12'6'5 15'3'15 18'2' 20'7'8 23' 25'7'4 28'0"4 30'7"8 332' 3'1 "9 Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.145 D 999 480 A 1261 /174 /771 /- /24 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA 4 VERT(TL): 0.458 D 757 360 U 2224 /355 /929 /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.030 B - d AB 790 /119 /362 /- /- /6.5 Des Ld: 65.00 J EXP:D HORZ(TL): 0.059 B - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.848 U Min Brg Width Req= 2.3 BCDL:3.0psf TPI Std: 2014 Max BC CSI: 0.970 AB Min Brg Width Req= 1.5 Load Duration:1.00 Bearings A,U,&AB Fcperp=565psi. Spacing:16.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.817 C&C Dist a:3.32 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 Lumber Wind A-B 232 -1586 H-I 1126 -174 C Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C C-D 4996 48 -3183 I-J 219 -13 member design. C-D -3331 J K 2311 -140 66 0 Top chord 2x6 SP#2 Ti: 2x4 SP#2: D-E 503 -3339 K-L 297 -2006 Bot chord 2x4 SP#2:B1 2x4 SP SS: E-F 295 -1918 L-M 297 -2006 Webs 2x4 SP#3:W2 2x4 SP#2: Additional Notes :W6 2x6 SP#2: The overall height of this truss excluding overhang is F-G 293 -247 M-N 208 1310 G H 2293 -468 Lumber value set"138"uses design values 1-8-0. approved 1/30/2013 by ALSC Maximum Bot Chord Forces Per Ply(lbs) Special Loads Chords Tens.Comp. Chords Tens. Comp. (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) A-AA 1146 -191 U-T 410 -2043 TC:From 80 plf at 0.00 to 80 plf at 33.17 AA-Z 1158 -194 T-S 156 -1031 BC:From 13 plf at 0.00 to 13 plf at 33.17 Z-Y 3397 -453 S-R 1406 -231 TC: 756 lb Conc.Load at 4.92 Y-X 3339 -503 R-Q 1417 -233 TC: 326 lb Conc.Load at 28.83 X-W 3319 -503 Q-P 1452 -235 Plating Notes W-V 1762 -275 P-O 24 -5 V-U 84 -504 All plates are 3X4 except as noted. (")6 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs) scaled plate plot details for special positioning Webs Tens.Comp. Webs Tens. Comp. requirements. _ -__- Plate positions consider a 0.50 inch truss perimeter AA-B 29 -111 H-T 1410 -298 edge distance. B-Z 2276 -280 T-I 187 -819 Z-C 137 -975 I-S 1716 -328 Purlins C-Y 118 -613 S-J 154 -702 In lieu of structural panels or rigid ceiling use purlins Y-D 176 -66 R-K 38 -126 to laterally brace chords as follows: X-E 191 -3 K-Q 922 -121 Chord Spacing(in oc) Start(ft) End(ft) E-W 234 -1674 L-Q 92 -594 TC 24 0.00 33.17 W-F 748 -93 Q-M 637 -86 BC 44 0.15 33.17 F-V 339 -1762 M-P 121 -646 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. V-G 838 140 P-N 1438 228 G-U 455 -2247 N-O 149 -760 U-H 267 -1135 NOTES: NI- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if*/\ APEX TrueHouse PE No.160 39Kozlowski PErNo 58544 on PE No 71457y PE No.Russell L 76238 Ply:1 SEAN:17707/T80/COMN Custom-Roick Res. Qty: 3 FROM: DRW: FG07,✓ Wgt:226.8 lbs Page 1 of 2 ... / ... 07/19/2018 F a67 1..3_6'6' 5 7J 31• I 7'2'3 ( 10'2' I 12'11" I 15'9' I 18'6'8 I 21'4'10( 24'0'3( 26'7.9_1 29'2'141 32'1'11 I 35'0'9 I 1 5 11 '-v5"/ 2'7"12 2'11'12 2'9" 2'10" 2'9"8 2'10'1 2'7"9 27'5 27'5 2'10'13 210'13 12 10.25 7 .6X8(") 4X8 "8X8(") m 4X8 m6X8 "4X10 8X8(") .4X4 416X10(") B C D T2 E F G H T3 I J K L T4 M N goT 4X8(")A I I l� w4X4(A1T) T 111 �z ^ 101'2 AC AB AA Z Y X Nh B2 V U T S R o P m -4X8 =4X8 =8X8(••) .4X8- '=4X10=4X10 mi8X12(') '•4X10 I AIF r 164'4 1 151'12 1 210'12 I 210' I 2'11'4_I 2'7'4 I 210 I 29' I 28'1 I 2'9'1 I 30'5 �I 29'1 -I 30 5 1 29'5 I I-9-"I am{�1, 4'27 70'7 9'11'12 127' 15'5' 182' 2010'2 237"3 267'9 29'4'10 32'4'15 35'2'5 .1.22.11 7 3"11 36'{ Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NAAVERT(LL): 0.125 K 999 480 A 1202 /204 /715 /- /75 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.445 K 799 360 W 2923 /458 /1613/- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.020 B - VO 1081 /182 /586 /- /- /6.5 Des Ld: 65.00#1 EXP:D . HORZ(TL): 0.042 B - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.756 W Min Brg Width Req= 3.1 Load Duration: 1.00 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.984 0 Min Brg Width Req= 1.5 MWFRS Parallel Dist:>2h RepFactors Used:Yes Max Web CSI: 0.983 Bearings A,W.&0 Fcperp=565psi. Spacing:16.0" C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Wind Duration: 1.60 WAVE I VIEW Ver:18.01.008.0430.21 Chords Tens.Comp. Chords Tens. Comp. Lumber Wind A-B 277 -1640 I-J 537 -2124 Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C B-DC 532 -3255 J-K 690 -3619 Topchord 2x4 SP#2:T2,T4 2x6 SP#2: member design. C-D 678 -3055 K-L 690 -3619 D-E 686 -3)67 L-M 535 -2825 :T3 2x6 SP SS Dense: Additional Notes E-F 794 -1367 M-N 522 -2767 Bot chord 2x6 SP SS Dense:B2 2x6 SP#2: F-G 1991 -391 N-O 227 -1212 Webs 2x4 SP#3:W2,W5 2x4 SP#2: The overall height of this truss excluding overhang is G-H 4015 -602 0-P 92 -25 Lumber value set"13B"uses design values 1-8-0. H-I 1353 -258 approved 1/30/2013 by ALSC Top Chord overhang(s)may be field trimmed. Special Loads Maximum Bot Chord Forces Per Ply(lbs) (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) Chords Tens.Comp. Chords Tens. Comp. TC:From 80 plf at 0.00 to 80 plf at 38.28 A-AC 1233 -207 W-V 624 -3616 BC:From 13 plf at 0.00 to 13 plf at 36.50 AC-AB 1231 -208 V-U 290 -1210 TC: 756 lb Conc.Load at 4.92 AB-AA 3401 -571 U-T 2380 -560 TC: 744 lb Conc.Load at 25.83 AA-Z 3067 -686 T-S 2859 -544 Plating Notes Z-Y 3024 -687 S-R 2825 -535 Y-X 1196 -924 R-Q 920 -173 All plates are 3X4 except as noted. X-W 370 -2110 Q O 905 -168 (")7 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. Plate positions consider a 0.50 inch truss perimeter edge distance. AC-B 60 0 H-V 2674 -391 B-AB 2157 -353 V-I 205 -1264 Purlins AB-C 170 -832 I-U 2670 -368 In lieu of structural panels or rigid ceiling use purlins C-AA 66 -851 U-J 176 -1153 to laterally brace chords as follows: AA-D 134 -100 J-T 1510 -212 Chord Spacing(in oc) Start(ft) End(ft) Z-E 441 -34 T-L 870 -161 TC 24 0.00 38.28 E-Y 294 -2175 K-T 117 -822 BC 38 0.15 36.35 Apply purlins to any chords above or below fillers Y-F 851 -103 L-S 76 -295 at 24"OC unless shown otherwise above. F-X 372 -2110 M-R 123 498 X-G 902 -140 R-N 2065 -381 G-W 452 -2346 N-Q 59 -180 NOTES: lir 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 6H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,f*1\ APEX TrueHouse Michael G Kozlowski Jeffrey P Ameson Derek B Murray Adam K Russell PE No.60839 PE No.58544 PE No.71457 PE No.77693 76238 Ply:1 SEQN:17707/T80/COMN Custom-Roick Res. Qty: 3 FROM: DRW: FG07 Wgt:226.8 lbs Page 2 of 2 ... / ... 07/19/2018 --- W-H 298 -1703 NOTES: II' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. 61'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX Tru eHo u se Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell PE No.60839 PE No.58544 PE No.71457 PE No.77693 76238 Ply:2 SEQN:17739/T22/COMN Custom-Roick Res. Qty: 1 FROM: DRW: FG08 Wgt:462.0 lbs Page 1 of 2 ... / ... 07/19/2018 - ', 7 L15.j7 2109 7110 9'10' 12'11'5 ` 15'7'151 18'7'8 21'r15I 24r14 26'9'5 29'5'31 322'14 35'0'9 I'5. 11'5'7 2'9"9 2'8'5 3'1'5 2'8'9 2'11"9 2'6'7 2'11"15 2'7'7 2'7'15 2'9'11 2'9'11 12 10.25 7 /6X8("") =4X8 m4X5v4X10 m8X8("') m4X10 T3 =8X8("") =5X5(") B C D ET2 F G H I J=4X8 K L MU N mT w4X8('')��=�_` 2�I\ _� .. ._:_ �. I�. mo\ 3X4(A1) T 11 10'1.2 AC AB AA Z 82 Y X K V U T S R 0 \F' io m4X10 mH1010("") =4X5 114X4 m6X8 m8XIi") 4X10 m8X12(") 1 r 18'4'4 -1 181'12 1 lI 26'13 I 211'9 I 210'1 1 211'13 I 27'13 I 210'9 I 28'3 I 30"15 I 29'11 I 2117 I 2'9'11 I 27'15 I L 195 310'9 610'2 9'8'4 12'8'1 153'15 18'2'8 20'10'11 23'11'10 26'9'5 298'11 32'6'6 352'5 13H1 1 Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA , VERT(LL): 0.165 E 999 480 2403 '232 /401 /- /75 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA Ar VERT(TL): 0.582 E 611 31/ 4003 '514 /772 /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.027 B - - 1043 '189 /420 /- /- /6.5 Des Ld: 65.00 4/ EXP:D _ HORZ(TL): 0.059 B - - ind reactions based on MWFRS NCBCLL:0.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.725 W Min Brg Width Req= 2.4 BCDL:3.0 sf TPI Std: 2014 Max BC CSI: 1.000 0 Min Brg Width Req= 1.5 Load Duration:1.00 P Bearings A,W,&0 Fcperp=565psi. Spacing:16.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.966 C&C Dist a:3.65 ft ' FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE,HS VIEW Ver:18.01.008.0430.21 Lumber Plating Notes A-B 154 -1642 I-J 583 -450 C Value Set:13B(Effective 6/1/2013) All plates are 3X4 except as noted. C-D 296 -1112 J-K 404 -1686 C-D 483 -4988 K-L 404 -1686 Top chord 2x4 SP#2:T2 2x6 SP SS Dense: (")8 plate(s)require special positioning.Refer to D-E 489 -3883 L-M 340 -1457 :T3,T4 2x6 SP#2: scaled plate plot details for special positioning E-F 496 -3900 M-N 231 -1011 Bot chord 2x6 SP#2:B2 2x6 SP SS Dense: requirements. F-G 218 -717 N-O 125 -528 Webs 2x4 SP#3:W2 2x4 SP#2: Plate positions consider a 0.50 inch truss perimeter G-H 2100 -255 0-P 46 -12 Lumber value set"13B"uses design values edge distance. H-I 611 -394 approved 1/30/2013 by ALSC Purlins Nailnote Maximum Bot Chord Forces Per Ply(lbs) In lieu of structural panels or rigid ceiling use purlins Chords Tens.Comp. Chords Tens. Comp. Nail Schedule:0.131"x3",min.nails to laterally brace chords as follows: Top Chord:1 Row @ 5.00"o.c. Chord Spacing(in oc) Start(ft) End(ft) A-AC 1238 -115 W-V 227 -1871 Bot Chord: 1 Row @12.00"o.c. TC 24 0.00 38.28 AC-AB 1244 -116 V-U 450 -583 Webs :1 Row @ 4"o.c. BC 76 0.15 36.35 AB-AA 3577 -318 U-T 495 -555 Use equal spacing between rows and stagger nails Apply purlins to any chords above or below fillers AA-Z 5084 -498 T-S 1497 -352 in each row to avoid splitting. at 24"OC unless shown otherwise above. Z-Y 3900 -496 S-R 1082 -249 5"o.c.spacing of nails perpendicular and parallel to Y-X 3813 -490 R-Q 380 94 grain required in area over bearings greater than 5" Additional Notes The overall height of this truss excluding overhang is X-W 436 -317 Q O 376 93 Special Loads 1-8-0 (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) Maximum Web Forces Per Ply(lbs) TC:From 80 plf at 0.00 to 80 plf at 3.67 Webs Tens.Comp. Webs Tens. Comp. TC:From 215 plf at 3.67 to 215 plf at 4.73 TC:From 395 plf at 4.73 to 395 plf at 8.27 AC-B 11 -51 H-V 1975 -278 TC:From 215 plf at 8.27 to 215 plf at 9.88 B-AB 2317 -199 V-I 84 -477 TC:From 80 plf at 9.88 to 80 plf at 38.28 AB-C 97 -1047 U-J 62 -412 BC:From 13 plf at 0.00 to 13 plf at 36.50 C-AA 1561 -183 J-T 1472 -190 TC: 144 lb Conc.Load at 3.92 AA-D 63 -410 K-T 65 -486 TC:1512 lb Conc.Load at 9.27 D-Z 84 -1437 T-L 207 -57 TC: 631 lb Conc.Load at 25.83 Z-E 63 141 L-S 52 172 Wind Y-F 755 -64 S-M 415 -101 Wind loads based on MWFRS with additional C&C X-G 1231 -X-X 231 --119 M-R 77 -337 9 R-N 702 152 member design. G-W 273 -2382 N-Q 25 -31 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (16'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fit\ APEX TrueHouse PE No l 0839 owski PE rNo 58544 Arneson PE N0.71457y PE N0.7 69311 76238 Ply:2 SEQN:17739/T22/COMN Custom-Roick Res. Qty: 1 FROM: DRW: FG08 Wgt:462.0 lbs Page 2 of 2 ... / ... 07/19/2018 W-H 158 -976 NOTES: It 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03. should be used in conjunction with the architectural plans during installation. (1.rli) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Flonda Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No Michael 60839 lowski PE No.58544 PE No.71457y APE No.Russell 76238 Ply:1 SEQN:17724/T82/COMN Custom-Roick Res. Qty: 6 FROM: DRW: FG09 J Wgt:207.9 lbs ... / ... 07/19/2018 ' 187i 3's"9 I6315 ( 9'5'12I 12513I 156'7 ) 184'4I 2011" 9 238'3I 265'13I 29410I 31.111$ 350'9 3'5"9 2'10'5 31'13 301 a0"9 2913 27"5 28'9 299 210'13 77'5 I 379 a4X10(") =4X5 m 5X5(") =4X8 =6X8(") =4X4 •4X4 ti6X8(") 12 t:ttiB C F TG =4X81 J K T3 L M N 10.25 T 2:,� D D E E 2 H N;4X4(A1T) AB AA Z V X W 15V U T S q�dX4 Q P O m 10.1'2 113X8 =4X10 '•4X5 '18X8(") '`6X10 '•4X8 8X8(") Boa =3X8 1 1 18'4'4 1 18112 A 3'0'9 (_ 3'1"9 I 3'1'13 I 2'10.5 I 3'0' 1 I 3'1'13 )_ 2'11'5 I 2'8'9 ) 275 2'10'13 I 2'9'9 I 2'6'13 F 1'9'5{ 3'0'9 6'2'3 9.4 '12'2 5 15'2'7 18'4 4 21'3"10 24'0'3 26'7'9 29'6'6 32'3'15 34'10'1 1.7, 36'6' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.108 S 999 480 AB 928 /150 /435 /- /64 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA AtVERT(TL): 0.393 S 890 364 V 2641 /407 /1336/- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.021 A - N 1067 /185 /573 /- /- /6.5 Des Ld: 65.004, EXP:D HORZ(TL): 0.045 A - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 AB Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.783 V Min Brg Width Req= 2.7 BCDL:3.0 sf TPI Std: 2014 Max BC CSI: 0.972 N Min Brg Width Req= 1.5 Load Duration:1.00 P Bearings AB,V,&N Fcperp=565psi. Spacing:16.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.943 C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 Lumber Wind A-B 340 -1878 H-I 1016 -313 Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C C-C 502 -2385 I-J 537 -3 member design. C D 509 2315 J K 6311 -311 2 72 Top chord 2x4 SP#2:T2 2x4 SP SS: D-E 608 -1275 K-L 624 -3149 :T3 2x4 SP#1: Camber E-F 1375 -303 L-M 430 -2140 Bot chord 2x6 SP#2:B3 2x6 SP SS Dense: F-G 3234 -543 M-N 252 -1241 Webs 2x4 SP#3:W1 2x6 SP#2: Max JT VERT DEFL:LL:0.11"DL:0.30".See detail G-H 3234 -543 N-O 92 -24 Lumber value set"138"uses design values DEFLCAMB1014 for camber recommendations. approved 1/30/2013 by ALSO Provide for adequate drainage of roof. Maximum Bot Chord Forces Per Ply(lbs) Special Loads Additional Notes Chords Tens.Comp. Chords Tens. Comp. (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) The overall height of this truss excluding overhang is AB-AA 114 -60 U-T 2074 -524 TC:From 80 plf at 0.00 to 80 plf at 38.28 1-8-0. AA-Z 2035 -309 T-S 3196 -635 BC:From 13 plf at 0.00 to 13 plf at 36.50 Top Chord overhang(s)may be field trimmed. Z-Y 2315 -509 S-R 3172 -631 TC: 325 lb Conc.Load at 3.92 Y-X 2293 -514 R-Q 2288 -461 TC: 631 lb Conc.Load at 25.83 X-W 1172 -582 Q P 922 -185 Plating Notes W-V 290 -1465 P-N 916 -185 V-U 290 -1144 All plates are 3X4 except as noted. (")6 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs) scaled plate plot details for special positioning requirements. Webs Tens.Comp. Webs Tens. Comp. Plate positions consider a 0.50 inch truss perimeter A-AB 187 -866 V-H 43) -2637 edge distance. A-AA 1979 -352 H-U 1072 -130 AA-B 152 -713 U-I 336 -2378 Purlins B-Z 281 -501 I-T 722 -86 In lieu of structural panels or rigid ceiling use purlins Z-C 74 -235 T-J 229 -1313 to laterally brace chords as follows: Y-D 285 -4 J-S 91 -338 Chord Spacing(in oc) Start(ft) End(ft) D-X 221 -1389 K-R 63 -210 TC 24 0.00 38.28 X-E 551 -79 R-L 1001 -184 BC 64 0.00 36.35 E-W 361 -1738 L-Q 145 -691 Apply purlins to any chords above or below fillers W-F 720 -129 Q M 1372 -269 at 24"OC unless shown otherwise above. F-V 482 -2183 P-M 69 -15 G-V 91 -319 NOTES: 111- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PEi No.l 0 391owskiPErey 58544son DerNo.71457y APE No.7 69311 76238 Ply:1 SEQN:17727/T43/COMN Custom-Roick Res. Qty: 2 FROM: DRW: FG10 it Wgt:205.1 lbs ... / ... 07/19/2018 36'6' 35'9 6'3"15 9'5'12 12'5'13 15'6'7 18'4'4 2011"10 239'3 26'5"13 29'4'10 31'11'15 35'0'9 3'5'9 I 2'10'5 ) 3'1'13 I 3'0'1 I 3'0"9 I 2'9"13 ( 2'7"5 I 2'8'9 ) 2'9"9 I 2'10'13 I 2'7'5 I 3'0'9 12 4X10(") ?`4X5 ?•5X5(") wi 4X8 =6X8(") ?`4X4 w 4X4 416X8(")" 10.25 AW1 B C (JDA\ E F T2 G H w4X81 J K T3 L M mT U / N=4X4(A1) 1 W Ns r 10'1'2 AA, Z V X W V Jr T S R =4X4 P O II3X8 ,4X10 -4X5 w8X8(") -6X10 a4X8 w8X8(") B3 -3X8 It 1 18'4'4 -1. 18x12 1 I 3'0'9 I 3'1'9 I 3'1'13 I 2'10'5 I 3'0'1 I 3'1'13 I 2'11'5 I 2'8'9 I 2'7'5 I 2'10'13 I 2'9'9 I 2'6'13 1 3'0'9 6'2'3 9'4' 12'2'5 15'2'7 18'4'4 21'3'10 24'0'3 26'7'9 29'6"6 32'3'15 34'10'13 36'6" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.108 R 999 480 AA 927 /147 /433 /- /24 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA JVERT(TL): 0.393 R 890 360 U 2641 /407 /1336/- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.021 A - it N 917 /137 /462 /- /- /6.5 Des Ld: 65.00/ EXP:D HORZ(TL): 0.045 A - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 AA Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.783 U Min Brg Width Req= 2.7 BCDL:3.0 sf TPI Std: 2014 Max BC CSI: 0.972 N Min Brg Width Req= 1.5 Load Duration:1.00 P Bearings AA,U,&N Fcperp=565psi. Spacing:16.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.942 C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 18.01.008.0430.21 Lumber Wind A-B 335 -1878 H-I 1013 -190 B-C 456 -2287 I-J 247 -2218 Value Set: 13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C C-D 463 -2314 J-K 437 -3172 Top chord 2x4 SP#2:T2 2x4 SP SS: member design. D-E 600 -1273 K-L 430 -3149 :T3 2x4 SP#1: Camber E-F 1375 -145 L-M 406 -2140 Bot chord 2x6 SP#2:B3 2x6 SP SS Dense: F-G 3234 -574 M-N 246 -1241 Webs 2x4 SP#3:W1 2x6 SP#2: Max JT VERT DEFL:LL:0.11"DL:0.30".See detail G-H 3234 -574 Lumber value set"13B"uses design values DEFLCAMB1014 for camber recommendations. approved 1/30/2013 by ALSC Provide for adequate drainage of roof. Maximum Bot Chord Forces Per Ply(lbs) Special Loads Additional Notes Chords Tens.Comp. Chords Tens. Comp. (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) The overall height of this truss excluding overhang is AA-Z 45 -13 T-S 2074 -228 TC:From 80 plf at 0.00 to 80 plf at 36.50 1-8-0. Z-Y 2035 -326 S-R 3196 -391 BC:From 13 plf at 0.00 to 13 plf at 36.50 Y-X 2314 -422 R-Q 3172 -395 TC: 325 lb Conc.Load at 3.92 X-W 2291 -422 Q-P 2288 -386 TC: 631 lb Conc.Load at 25.83 W-V 1169 -597 P-O 922 -161 Plating Notes V-U 179 -1465 O-N 916 -162 All plates are 3X4 except as noted. U-T 220 -1142 (")6 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs) scaled plate plot details for special positioning requirements. Webs Tens.Comp. Webs Tens. Comp. Plate positions consider a 0.50 inch truss perimeter A-AA 185 -866 U-H 451 -2637 edge distance. A-Z 1979 -347 H-T 1072 -140 Z-B 149 -713 T-I 358 -2378 Purlins B-Y 280 -498 I-S 722 -98 In lieu of structural panels or rigid ceiling use purlins Y-C 73 -235 S-J 265 -1313 to laterally brace chords as follows: X-D 285 -6 J-R 93 -352 Chord Spacing(in oc) Start(ft) End(ft) D-W 229 -1389 K-Q 61 -208 TC 24 0.00 36.50 W-E 551 -81 Q-L 972 -67 BC 64 0.00 36.35 E-V 366 -1738 L-P 100 -674 Apply purlins to any chords above or below fillers V-F 720 -130 P-M 1340 -222 at 24"OC unless shown otherwise above. F-U 485 -2183 O M 69 0 G-U 92 -319 NOTES: It I.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 "V\ APEX TrueHouse PE No l 08391owskirey P No 58544 Arneson PEPE No 71457y APE No.7 69311 , 76238 Ply: 1 SEAN:17730/T83/COMN Custom-Roick Res. Qty: 1 FROM: DRW: FG11 J Wgt:205.1 lbs ... / ... 07/19/2018 36'6" 3'5'9 6'3'15 9'5'12 12'5'13 15'6'7 18'4'4 20'11"10 23'8'3 26513 29'4"10 31'11"15 35'0"9 I 3'5'9 If` 3'1'13 I 3'0'1 I 3'0"9 111111 275 I 3'0'9 I 12 4X10(") .4X5 .5X5(") a4X8 O =6X8(") .4X4 .4X4 6X8("). 10.25 1 AWS B C D E (J H -.4X81KK T'C3 L M m N=4X4(A1) _ 10'1'2 AA,XB •4 Z Y X w V 6X10 T S R '4X4 P 0 ' X10 .4X5 "8X8(") ?•4X8 =8X8(") B33X8 At A 18'4.4 A 18'1.12 A 3'0'9 3'1'9 3'113 2'10'5 3'0'1 31'13 2'11'5 2'8'9 27'5 21013 2'9'9 2613 II-1 ` 6'2'3 I 9'4' III 18'4'4 I 21'3"10 I 24'0'3 I 26'7'9 I 29'6'6 I 32'3'15 I 34'10'131 1 73 r 36'6..1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.108 R 999 480 AA 927 /147 /433 /- /24 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA 4,0PVERT(TL): 0.394 R 889 360U 2642 /407 /1337/- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.021 A - W N 915 /137 /462 /- /- /- Des Ld: 65.00 J EXP:D HORZ(TL): 0.045 A - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 AA Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.783 U Min Brg Width Req= 2.7 Load Duration:1.00 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.974 N Min Brg Width Req= - Spacing:16.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.942 Bearings AA&U Fcperp=565psi. C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 Lumber Hangers/Ties A-B 335 -1877 H-I 1013 -190 (Effective 6/1/2013) B-C 455 -2287 1-J 247 -2220 Value Set:13B (J)Hanger Support Required,by others C-D 463 -2313 J-K 438 -3179 Top chord 2x4 SP#2:T2 2x4 SP SS: Wind D-E 600 -1272 K-L 432 -3156 :T3 2x4 SP#1: E-F 1377 -146 L-M 408 -2151 Bot chord 2x6 SP#2:B3 2x6 SP SS Dense: Wind loads based on MWFRS with additional C&C F-G 3236 -575 M-N 248 -1256 Webs 2x4 SP#3:W1 2x6 SP#2: member design. G-H 3236 -575 Lumber value set"13B"uses design values Camber approved 1/30/2013 by ALSC Max JT VERT DEFL:LL:0.11"DL:0.30".See detail Maximum Bot Chord Forces Per Ply(lbs) Special Loads DEFLCAMB1014 for camber recommendations. Chords Tens.Comp. Chords Tens. Comp. (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) Provide for adequate drainage of roof. AA-Z 45 -13 T-S 2076 -228 TC:From 80 pIf at 0.00 to 80 plf at 36.50 Additional Notes Z-Y 2034 -326 S-R 3202 -393 BC:From 13 pIf at 0.00 to 13 pIf at 36.50 Y-X 2313 -421 R-Q 3179 -396 TC: 325 lb Conc.Load at 3.92 The overall height of this truss excluding overhang is X-W 2291 -422 Q-P 2298 -387 TC: 631 lb Conc.Load at 25.83 1-8-0. W-V 1169 -597 P-O 937 164 Plating Notes V-U 179 -1468 O-N 929 -165 U-T 220 -1142 All plates are 3X4 except as noted. (")6 plate(s)require special positioning.Refer to scaled plate plot details for special positioning Maximum Web Forces Per Ply(lbs) requirements. Webs Tens.Comp. Webs Tens. Comp. Plate positions consider a 0.50 inch truss perimeter A-AA 185 -866 U-H 451 -2640 edge distance. A-Z 1978 -347 H-T 1073 -140 Z-B 149 -713 T-1 358 -2381 Purlins B-Y 279 -498 I-S 723 -98 In lieu of structural panels or rigid ceiling use purlins Y-C 73 -235 S-J 265 -1317 to laterally brace chords as follows: X-D 285 -6 J-R 93 -352 Chord Spacing(in oc) Start(ft) End(ft) D-W 229 -1390 K-Q 61 -208 TC 24 0.00 36.50 W-E 551 -81 Q-L 968 -67 BC 64 0.00 36.38 E-V 366 -1738 L-P 100 -672 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. V-F 720 -130 P-M 1335 222 F-U 485 -2183 O-M 73 0 G-U 92 -319 NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111''FI) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 /f*/\ APEX TrueHouse PE No.08391owskiJeffrey No 58544son PEPE Na Murray71457 PE No.7769311 76238 Ply:2 SEQN:17746/T17/COMN Custom-Roick Res. Qty: 1 FROM: DRW: FG12 J Wgt:464.8 lbs ... / ... 07/19/2018 1.,•31.) 71,5.7 28 6 692 9'5"8 12'613 15'5"7 184"4 21'0'3 23'9"6 269'5 29'5"3 32'2'14 35'0"9 15 I I I ) I I ( I I I I (' 57 276 286 315 21010 21013 2715 293 21115 27"15 2911 2911 12 10.25 V /6X8("") =4X8 m4X8O =4X10 =8X8(") v4X4 v 4X80 m8X8('") 5X5('") B C D E T2 F G H I J 3 K L M 0 N mT ,.4X8(")A R/��l/ _3X4(A1) 11 �2 I 'C7 YS 10'1"2 AB AA ZY X W �6X12,V U T S 83 R C P =4X10 =H1010(-) i.4X8 =6X8 .� 48X8(",) 1 18'4"4 1 18'1"12 i 4" L 2'4.10� 2'9°6 � 2714 � 21113 � 3'0.5 ( 3'2"9 ) 2'11"7 I 2'7.15 ) 2'11'7 I 2'9"11 ( 2'9.11 � 27'15 � ' 1, 3'8"5 6'5"10 9'1'8 12'1'5 15'1"11 18'4'4 21'3"11 23'11"10 26'11"1 29'8'11 32'6'6 35'2'5 1LL3�1JJ1 1 s Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pt in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA CI:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA 1VERT(LL): 0.143 Y 999 480 A 2520 159 /280 /- /29 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.518 Y 686 360 V 4618 505 /803 /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.025 B - J 0 764 '128 /289 /- /- /- Des Ld: 65.00If EXP:D HORZ(TL): 0.054 B - - Wind reac ions based on MWFRS NCBCLL:0.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.777 V Min Brg Width Req= 2.4 Load Duration:1.00 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.984 0 Min Brg Width Req= - MWFRS Parallel Dist:h to 2h RepFactors Used:Yes Max Web CSI: 0.849 Bearings A&V Fcperp=565psi. Spacing:16.0" C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE,HS VIEW Ver:18.01.00B.0430.21 Lumber Plating Notes A-B 121 -1721 H-I 3244 304 B-C 204 -3373 I-J 2079 -115 Value Set:13B(Effective 6/1/2013) All plates are 3X4 except as noted. C-D 271 -5026 J-K 809 -799 Top chord 2x4 SP#2:T2,T4 2x6 SP#2: (")7 plate(s)require special positioning.Refer to D-E 329 -5256 K-L 797 -795 :T3 2x6 SP SS Dense: scaled plate plot details for special positioning E-F 189 -3372 L-M 252 -1185 Bot chord 2x6 SP SS Dense:B3 2x6 SP#2: requirements. F-G 539 -167 M-N 206 -865 Webs 2x4 SP#3:W2 2x4 SP#2: Plate positions consider a 0.50 inch truss perimeter G-H 3244 -304 N-O 122 -504 Lumber value set"13B"uses design values edge distance. approved 1/30/2013 by ALSO Purlins Maximum Bot Chord Forces Per Ply(lbs) Nailnote Chords Tens.Comp. Chords Tens. Comp. In lieu of structural panels or rigid ceiling use purlins Nail Schedule:0.131"x3",min.nails to laterally brace chords as follows: A-AB 1300 -80 V-U 134 -2189 Top Chord:1 Row @ 4.25"o.c. Chord Spacing(in oc) Start(ft) End(ft) AB-AA 1305 -81 U-T 769 -836 Bot Chord:1 Row @12.00"o.c. TC 24 0.00 36.50 AA-Z 3615 -199 T-S 799 -809 Webs :1 Row @ 4"o.c. BC 99 0.15 36.38 Z-Y 5191 -281 S-R 1189 -233 Use equal spacing between rows and stagger nails Apply purlins to any chords above or below fillers Y-X 5284 -339 R-Q 922 -200 in each row to avoid splitting. at 24"OC unless shown otherwise above. X-W 2820 -174 Q P 376 -82 4"o.c.spacing of nails perpendicular and parallel to grain required in area over bearings greater than 4" Wind W-V 90 -699 P-O 376 -81 Special Loads Wind loads based on MWFRS with additional C&C member design. Maximum Web Forces Per Ply(lbs) (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) Webs Tens.Comp. Webs Tens. Comp. TC:From 80 plf at 0.00 to 80 plf at 3.67 Additional Notes AB-B 9 -43 H-V 65 -375 TC:From 215 plf at 3.67 to 215 plf at 4.73 The overall height of this truss excluding overhang is TC:From 446 plf at 4.73 to 446 plf at 8.27 1-8-0. BAA L3dU -116 V-I 211 -1325 TC:From 215 plf at 8.27 to 215 plf at 9.88 AA-C 64 -1117 I-U 742 -82 IC:From 80 plf at 9.88 to 80 plf at 36.50 C-Z 1563 -89 U-J 252 -2110 BC:From 13 plf at 0.00 to 13 plf at 36.50 Z-D 43 -703 J-T 305 -27 TC: 144 lb Conc.Load at 3.92 D-Y 73 -142 K-S 104 -29 TC: 1840 lb Conc.Load at 9.27 Y-E 41 -118 S-L 111 -726 TC: 631 lb Conc.Load at 25.83 E-X 164 -2501 L-R 166 16 Hangers/Ties X-F 1107 -65 R-M 292 -142 (J)Hanger Support Required,by others F-W 241 -2989 M-Q 62 -244 W-G 1166 -83 Q-N 543 -116 G-V 258 -2939 N-P 12 -1 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11..1.1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if"\ APEX TrueHouse PE No Michael 0839lowski Jeffrey 5Arneson 58544PE No Murray1457APE No.7769 Russell 76238 Ply:2 SEQN: 17677/T7/MONO ' Custom-Roick Res. Qty: 1 FROM: DRW: FG131 Wgt:134.4 lbs ... / ... 07/19/2018 2'10"3 5'11"2 9'0"1 11'10"4 2'10"3 I 3'0"15 I 3'0"15 I 2'10"3 A =6X18(") =41O =6X10(") E 1113X4 1113X4 -r 0W1 oz, �_ -.---::------'-------- ---'2 .11 I -/.." ___,,)0.0 1012 j 8X8(1) -4X5 1113X4 . 5 =8X8(1) F O A 11'10"4 i 3'3"3I 2'7"15 I 2'7"15 I 3'3"3 3'3"3 5'1 1"2 8'7"1 11'10"4 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.109 H 999 4801 J 5005 762 /558 /- /- /- BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA 4/VERT(TL): 0.300 H 695 360 F 4864 /736 /558 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.024 F - 4/- Wind reactions based on MWFRS Des Ld: 65.00 At EXP:D HORZ(TL): 0.044 F - - J Min Brg Width Req= - NCBCLL:0.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= - Soffit: 0.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.866 Load Duration:1.00 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.628 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.866 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 17 -112 C-D 671 -4420 GCpi:0.18 Plate Type(s): B-C 677 -4455 D-E 17 -110 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 Lumber Purlins Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#1 to laterally brace chords as follows: J-I 4258 -649 H-G 5700 -868 Bot chord 2x6 SP SS Dense Chord Spacing(in oc) Start(ft) End(ft) I-H 5700 -868 G-F 4226 -643 Webs 2x4 SP#3:W1 2x6 SP#2: TC 24 0.00 11.85 :W2 2x4 SP#2: BC 120 0.00 11.85 Apply purlins to any chords above or below fillers Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values at 24' OC unless shown otherwise above. Webs Tens.Comp. Webs Tens. Comp. approved 1/30/2013 by ALSC The TC of this truss shall be braced with attached spans at 24"oc in lieu of structural sheathing. A-J 67 -419 C G 219 -1423 Nailnote J•B 689 -4521 G-D 881 -126 Nail Schedule:0.131"x3",min.nails Hangers/Ties B-I 895 -129 D-F 683 -4488 Top Chord:1 Row @ 4.25"o.c. (J)Hanger Support Required,by others I-C 212 -1384 E-F 67 -419 Bot Chord:1 Row 8.75"o.c. C-H 352 -49 Webs : 1 Row CO 4"o.c. Use equal spacing between rows and stagger nails Wind in each row to avoid splitting. Wind loads based on MWFRS with additional C&C member design. Special Loads (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) Additional Notes TC:From 602 plf at 0.00 to 602 plf at 11.85 Truss must be installed as shown with top chord up. BC:From 245 plf at 0.00 to 245 plf at 9.85 The overall height of this truss excluding overhang is BC:From 25 plf at 9.85 to 25 plf at 11.85 1-8-0. BC: 270 lb Conc.Load at 10.85 Plating Notes (I)-plates so marked were sized using 0% Fabrication Tolerance,0 degrees Rotational Tolerance,and/or zero Positioning Tolerance. (")2 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. NOTES: Nr 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61'1M 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer i Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi /\ TrueHouse Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX PE No.60839 PE No.58544 PE No.71457 PE No.77693 76238 Ply:4 SEQN:17754/T52/MONO Custom-Roick Res. Qty: 1 FROM: DRW: FG14 J Wgt:632.8 lbs ... / ... 07/19/2018 L. 27"9 I 5'3"10 I T11"3 I 10'6"4 I 13'4"12 I 151113 I 18'7"6 I 21'3"7 I 2311" 'i 2'7"9 2'8"1 2'7"9 2'7"1 2'10"9 2'7"1 2'7"9 2'8"1 2'7"9 =4X10 =4X8 =8X8(") =4X5 =4X8 A B C D E F G H 1=4X10 J T v �� / ��' \� � w1 I _ X 8'r2 T lal S R Q P 0 N M L 126-KU 4X10('") =4X8 =H1010("") H1010("") =4X8 =4X10("") (I) (I) r 2311" 1 31"1 I 2'6"9 I 271 I 2'5"5 I 2'7"1 I 2'5"5 I 2'7"1 { 2 6"9 I 3 1 1 3'1"1 5'7"10 8'2"11 10'8" 13'3" 15'8"5 18'3"6 20'9"15 2311" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg, •n PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA C • e ection in lot Udefl U# L.. R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.315 P 910 i;# T 6151 /- /- /- /- /6.0 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.955 P 452 •1 U 6151 /- /- /- /- /6.0 BCDL: 10.00 Category:NA Snow Duration:NA nunctt-y. u.uau r - _rg Width Req= 1.8 Des Ld: 65.00 J EXP:NA HORZ(TL): 0.101 K - - U Min Brg Width Req= 1.8 NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Bearings T&U Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.517 Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.677 Maximum Top Chord Forces Per Ply(lbs) Spacing:16.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.818 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 0 -52 F-G 0 -6536 I:NA GCpi:NA Plate Type(s): , B-C 0 -3153 G-H 0 -5224 Wind Duration:NA WAVE,HS VIEW Ver:18.01.00B.0430.21 C-D 0 -5224 H-I 0 -3153 Lumber Plating Notes D-E 0 -6541 I-J 0 52 E-F 0 -7183 Value Set:13B(Effective 6/1/2013) All plates are 3X4 except as noted. Top chord 2x6 SP SS Dense (I)-plates so marked were sized using 0% Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x6 SP SS Dense Fabrication Tolerance,0 degrees Rotational Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3:W1 2x6 SP#2: Tolerance,and/or zero Positioning Tolerance. Lumber value set"13B"uses design values ("')5 plate(s)require special positioning.Refer to T-S 2923 0 0-N 7183 0 approved 1/30/2013 by ALSC scaled plate plot details for special positioning S-R 5060 0 N-M 6455 0 requirements. R-0 6461 0 M-L 5061 0 Nailnote Plate positions consider a 0.50 inch truss perimeter Q-P 7183 0 L-K 2923 0 Nail Schedule:0.131"x3",min.nails edge distance. P-O 7183 0 Top Chord:1 Row @ 3.50"o.c. Bot Chord:1 Row @12.00"o.c. Purlins Maximum Web Forces Per Ply(lbs) Webs :1 Row @ 4"o.c. In lieu of structural panels or rigid ceiling use purlins Webs Tens.Comp. Webs Tens. Comp. Repeat nailing as each layer is applied.Use equal to laterally brace chords as follows: spacing between rows and stagger nails in each row Chord Spacing(in oc) Start(ft) End(ft) A-T 0 -212 O-F 16 0 to avoid splitting. TC 24 0.00 23.92 T-B 0 -3135 F-N 0 -731 In addition apply(1)1/2"bolt or 0.22"-0.25"min/max dia.X 6.0" BC 120 0.00 23.92 B-S 980 0 N-G 346 0 length wood screw at each joint location. Apply purlins to any chords above or below fillers S-C 0 -2154 G-M 0 -1391 4"o.c.spacing of nails perpendicular and parallel to at 24"OC unless shown otherwise above. grain required in area over bearings greater than 4" C-R 698 0 M-H 694 0 The TC of this truss shall be braced with attached R-D 0 -1398 H-L 0 -2156 Special Loads spans at 24"oc in lieu of structural sheathing. D-Q 342 0 L-I 981 0 (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) Q-E 0 -725 I-K 0 -3135 TC:From 500 plf at 0.00 to 500 plf at 7.77 E-P 16 0 J-K 0 -212 TC:From 502 plf at 7.77 to 502 plf at 16.15 TC:From 500 plf at 16.15 to 500 plf at 23.92 BC:From 13 plf at 0.00 to 13 plf at 23.92 Additional Notes Truss must be installed as shown with top chord up. The overall height of this truss excluding overhang is 1-8-0. NOTES: NII- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11-11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 /f*/\ APEX TrueHouse PE No l 0838lowski Jeffrey No 58544son PEPE Na Murray71457FE No.Russell 69311 76238 Ply:4 SEAN: 17760/T51/MONO ' Custom-Roick Res. Qty: 1 FROM: DRW: FG15 J Wgt:610.4 lbs ... / ... 07/19/2018 , 2'10"10 I 5'9"12 I 8'2"14 I 1077 I 13'3"9 I 15'8"2 I 18'1"4 I 21'0"6 I 23'11" '� 2'10"10 2'11"2 2'5"2 2'4"10 2'8"2 2'4"10 2'5"2 2'11"2 2'10"10 =4X10 =4X8 =5X5(") 10 A B C D E F G H 4X8 1=4X10 J ....---T '.. w 7:,.,.,_,---...:,,,b,:f ---- ....„.____t...,----..z.,-...,;,_____>_- ___..g w i 1 - _ 08'12 TIll S R 0 P 0 N M L IlikKU 4X10(") =4x8 sH 010(••) -H1010(") =4X8 -4X10(••) (I) 1 2311" .i 34"2 � 2'9"10 � 2,4"10 2'2°14 2'4"10 � 2'2"14 � 2'4"10 � 2'9"10 I 3'4"2 34"2 6'1"12 8'6"6 10'9"3 13'1"13 15'4"10 17'9"4 20'6"14 23'11" Loading Criteria(psf) Wind Criteria Snow Criteria( fin PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA T. A PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.315 P 909 480 T 6052 / /- /- /- /6.0 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.929 P 461 360 U 6052 / /- /- /- /6.0 BCDL: 10.00 Category:NA Snow Duration:NA HUHL(LL): O.Ob1 A - - I Min Brg Width Req= 1.8 Des Ld: 65.00 EXP:NA HORZ(TL): 0.101 A - - U Min Brg Width Req= 1.8 NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Bearings T&U Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.921 Load Duration: 1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.554 Maximum Top Chord Forces Per Ply(lbs) Spacing:16.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.879 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 0 -65 F-G 0 -5297 I:NA GCpi:NA Plate Type(s): B-C 0 -3176 G-H 0 -5035 Wind Duration:NA WAVE,HS VIEW Ver:18.01.00B.0430.21 C-D 0 -5017 H-I 0 -3187 Lumber Plating Notes D-E 0 -5303 I-J 0 62 Value Set:13B(Effective 6/1/2013) All plates are 3X4 except as noted. E-F 0 5394 Top chord 2x4 SP#2:T2 2x4 SP SS: (I)-plates so marked were sized using 0% Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x6 SP SS Dense Fabrication Tolerance,0 degrees Rotational Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3:W1 2x6 SP#2: Tolerance,and/or zero Positioning Tolerance. Lumber value set"13B"uses design values (")5 plate(s)require special positioning.Refer to T-S 2977 0 0-N 5392 0 approved 1/30/2013 by ALSC scaled plate plot details for special positioning S-R 4989 0 N-M 5280 0 requirements. R-0 5284 0 M-L 5007 0 Nailnote Plate positions consider a 0.50 inch truss perimeter Q-P 5392 0 L-K 2987 0 Nail Schedule:0.131"x3",min.nails edge distance. P-O 5394 0 Top Chord:1 Row @ 2.00"o.c. Bot Chord:1 Row @12.00"o.c. Purlins Maximum Web Forces Per Plylbs Webs 1 Row 4"o.c. (lbs) In lieu of structural panels or rigid ceiling use purlins Webs Tens.Comp. Webs Tens. Comp. Repeat nailing as each layer is applied.Use equal to laterally brace chords as follows: spacing between rows and stagger nails in each row Chord Spacing(in oc) Start(ft) End(ft) A-T 0 -187 0-F 23 0 to avoid splitting. TC 24 0.00 23.92 T-B 0 -3169 F-N 0 -112 In addition,apply(1)0.22"-0.25"min/max dia.X 6.0" BC 120 0.00 23.92 B-S 902 0 N-G 77 0 length wood screw at each joint location. Apply purlins to any chords above or below fillers 2"o.c.spacing of nails perpendicular and parallel to S C 0 -2033 G M 0 288 grain required in area over bearings greater than 2" at 24"OC unless shown otherwise above. C-R 124 0 M-H 128 0 The TC of this truss shall be braced with attached R-D 0 -315 H-L 0 -2040 Special Loads spans at 24"oc in lieu of structural sheathing. D-Q 87 0 L-I 907 0 (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) Additional Notes Q-E 0 -104 I-K 0 -3183 TC:From 500 plf at 0.00 to 500 plf at 5.00 E-P 25 0 J-K 0 -188 TC:From 138 plf at 5.00 to 138 plf at 6.00 Truss must be installed as shown with top chord up. TC:From 73 plf at 6.00 to 73 plf at 17.92 The overall height of this truss excluding overhang is TC:From 138 plf at 17.92 to 138 plf at 18.92 1-8-0. TC:From 500 plf at 18.92 to 500 plf at 23.92 BC:From 13 plf at 0.00 to 13 plf at 23.92 TC:2816 lb Conc.Load at 6.00,17.92 NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111."11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 1'rueHouse PE No l 08391owski Jrey P No 8Arneson PE PE No. MurrayDerek B1457Adam K PE No.77Russell APEX 76238 Ply:2 SEQN:17655/T78/FLAT • Custom-Roick Res. Ory: 1 FROM: DRW: FG16 4 Wgt:184.8 lbs / ... 07/19/2018 3'2"14I 6'6"13 _I 10'0"11 I 13'3"2 + 16'7"8H H 3'2"1 4 3'3"1 4 3'5"14 3'2"6 3'4"6 1113X4 =4X10 =4X5 =4X5 =6X8(") III 3X4 A B C D E T2 F T 111_‘2,v) _,. - n n ❑ W, co I ❑ 8'1„2 L K J B2 I H G O 6X8(") =6X10(") 1113X4 1113X4 =4X5 M 4X10(") I- 1678 1 3'7"14I 3'0"10 I 3'2"6 3'0"10 I 3'7"14 H3'7"14 6'8"9 9'10"15 12'11"10 16'7"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: NA mph Pf:NA Ce:NAVERT(LL): 0.130 J 999 480 L 3076 - /- /- /- /6.0 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA V VERT(TL): 0.546 J 627 360 M 3076 /- /- /- /6.5 BCDL: 10.00 Category:NA Snow Duration:NA HORZ(LL): 0.033 G - - L ivioi o Width Req= 1.8 Des Ld: 65.004 EXP:NA HORZ(TL): 0.083 G - - M Min Brg Width Req= 1.8 NCBCLL:0.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Bearings L&M Fcperp=565psi. Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.697 Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.709 Maximum Top Chord Forces Per Ply(lbs) Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI: 0.977 Chords Tens.Comp. Chords Tens. Comp. C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 0 -76 D-E 0 -3185 I:NA GCpi:NA Plate Type(s): B-C 0 -3184 E-F 0 -81 Wind Duration:NA WAVE VIEW Ver: 18.01.008.0430.21 C-D 0 -4487 Lumber Purlins Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP SS:T2 2x4 SP#2: to laterally brace chords as follows: Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#1 :B2 2x4 SP SS: Chord Spacing(in oc) Start(ft) End(ft) L-K 3052 0 I-H 4483 0 Webs 2x4 SP#3:W1 2x6 SP#2: TC 24 0.00 16.62 K-J 4483 0 H-G 3053 0 BC 120 0.00 16.62 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers J-I 4487 0 approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Nailnote The TC of this truss shall be braced with attached Maximum Web Forces Per Ply(lbs) spans at 24"oc in lieu of structural sheathing. Webs Tens.Comp. Webs Tens. Comp. Nail Schedule:0.131"x3",min.nails Top Chord:1 Row @ 7.25"o.c. A-L 0 -282 I-D 133 -69 Bot Chord:1 Row @12.00"o.c. L-B 0 -3215 D-H 0 -1542 Webs :1 Row @ 4"o.c. B-K 654 0 H-E 649 0 Use equal spacing between rows and stagger nails K-C 0 -1546 E-G 0 -3210 in each row to avoid splitting. C-J 130 -71 F-G 0 -283 Special Loads (Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00) TC:From 350 plf at 0.00 to 350 plf at 16.62 BC:From 20 plf at 0.00 to 20 plf at 16.62 Plating Notes (")4 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Additional Notes Truss must be installed as shown with top chord up. The overall height of this truss excluding overhang is 1-8-0. NOTES: I.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Tril) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse MichaePE No.160839 KozlowskiJeffrey No 58544 Arneson Adam K PEPE No.71457y APE No 7 69311 76238 Ply:1 SEAN:17599/T77/SY42 Custom- oick Res. Qty: 1 FROM: DRW: FGE01 Wgt:47.6 lbs ... / ... 07/19/2018 H 1'2"8 1'4" -H (TYP) A B C D E F G 3a p j - - - - - H bo I - - - - - — ict) 8'1"2 C I 1113X3 N M L K J 1113X3 I" 7'10" -I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or•=PLF TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.000 G 999 480 i" 84 /_ /_ /_ /_ /94.0 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA JVERT(TL): 0.000 G 999 36t l Min Brg Width Req= - BCDL: 10.00 Category:NA Snow Duration:NA HORZ(LL): 0.000 G - - Bearing 0 Fcperp=565psi. Des Ld: 65.00 J EXP:NA HORZ(TL): 0.000 G - - NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Maximum Top Chord Forces Per Ply(lbs) Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.114 Chords Tens.Comp. Chords Tens. Comp. Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.028 A-B 0 0 D-E 0 0 Spacing:16.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.023 B-C 0 0 E-F 0 0 C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: C-D 0 0 F-G 0 0 I:NA GCpi:NA Plate Type(s): Wind Duration:NA WAVE VIEW Ver:18.01.0OB.0430.21 Maximum Bot Chord Forces Per Ply(lbs) Lumber End Vertical Attachment Chords Tens.Comp. Chords Tens. Comp. Value Set: 13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical O-N 0 0 L-K 0 0 Top chord 4x2 SP#3 using(3)qty.10d box or(0.128"x3"min)gun nails,or N-M 0 0 K-J 0 0 Bot chord 4x2 SP#3 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire M-L 0 0 J-I 0 0 Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Crown(minimum),1-1/2"length wire staples on each Lumber value set"138"uses design values narrow face. Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Additional Notes Bracing Truss must be installed as shown with top chord up. P-O 0 8 G I 0 -29 Sheathing is required for any longitudinal(drag) A-0 0 -35 I-H 0 -7 forces.All connections to be designed by the building The overall height of this truss excluding overhang is designer. 1-8-0. Maximum Gable Forces Per Ply(lbs) Fasten rated sheathing to one face of this frame. Gables Tens.Comp. Gables Tens. Comp. Plating Notes B-N 0 -98 E-K 0 -100 All plates are 1.5X3 except as noted. C M 0 98 F-J 0 91 D-L 0 -97 Purlins In lieu of structural panels or rigid ceiling use puffins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.25 7.58 BC 88 0.25 7.58 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11:11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No I608391owski Jeffrey 58544 on PE PE No. Murray1457APE No.7769311 76238 Ply:1 SEQN:17600/T32/SY42 Custom-Roick Res. Qty: 1 FROM: DRW: FGE02 41 Wgt:56.0 lbs ... / ... 07/19/2018 1'2"8 --I-- 1'4" H (TYP) A B C D E F G H T e H11 - - L - - L LL i co T — r — — r F- 81„2 Q ,. -143- 1113X��//I�( " M �" K 1113X3 I" 9'2"4 1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or'=PLF TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: NA mph Pf:NA Ce:NA JVERT(LL): 0.000 H 999 480��a11• 85 I- /- /- /- /110 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.000 H 999 36(!/J Min Brg Width Req= - BCDL: 10.00 Category:NA Snow Duration:NA HORZ(LL): 0.000 H - - Bearing Q Fcperp=565psi. Des Ld: 65.00 J EXP:NA HORZ(TL): 0.000 H - - NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Maximum Top Chord Forces Per Ply(lbs) Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.114 Chords Tens.Comp. Chords Tens. Comp. Load Duration: 1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.028 A-B 0 0 E-F 0 0 Spacing:16.0" MW FRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.023 B-C 0 0 F-G 0 0 C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: C-D 0 0 G-H 0 0 I:NA GCpi:NA Plate Type(s): D-E 0 0 Wind Duration:NA WAVE VIEW Ver:18.01.00B.0430.21 Lumber End Vertical Attachment Maximum Bot Chord Forces Per Ply(lbs) Value Set: 13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical Chords Tens.Comp. Chords Tens. Comp. Top chord 4x2 SP#3 using(3)qty.10d box or(0.128"x3"min)gun nails,or Q-P 0 0 M-L 0 0 Bot chord 4x2 SP#3 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire p-Q 0 0 L-K 0 0 Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Q_N 0 0 K-J 0 0 Crown(minimum),1-1/2"length wire staples on each Lumber value set"13B"uses design values narrow face. N-M 0 0 approved 1/30/2013 by ALSC Additional Notes Maximum Web Forces Per Ply(lbs) Bracing Truss must be installed as shown with top chord up. Webs Tens.Comp. Webs Tens. Comp. Sheathing is required for any longitudinal(drag) The overall height of this truss excludingoverhangis forces.All connections to be designed by the building g R-Q 0 -8 H-J 0 -30 designer. 1-8-0. A-Q 0 -35 J-I 0 -7 Fasten rated sheathing to one face of this frame. Maximum Gable Forces Per Ply(lbs) Plating Notes Gables Tens.Comp. Gables Tens. Comp. All plates are 1.5X3 except as noted. g-p 0 98 E-M 0 97 Purlins C-0 0 -98 F-L 0 -99 In lieu of structural panels or rigid ceiling use purlins D-N 0 98 G-K 0 92 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.25 8.94 BC 104 0.25 8.94 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. NOTES: f' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. (Irrli) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi"\ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX TrueHouse PE No 60839 PE No 58544 PE No.71457 PE No.77693 76238 Ply: 1 SEQN:17601/T42/SY42 Custom-Roick Res. Qty: 1 FROM: DRW: FGE03 J Wgt:84.0 lbs ... / ... 07/19/2018 1'2"8 I„ I 1'4"H (TYP) A B C D E FG H 1 J K L Ty"6 z r - - - -,,M W 1 - -r 0 10'1"2 1113X3 X W V U T S R Q P 0 1113X3 I 14'4"12 i Loading Criteria(pst) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or'=PLF TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 15.00 Speed: NA mph Pf:NA Ce:NA , VERT(LL): 0.000 J 999 480 y* 85 /- /- /- /- /172 BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.000 J 999 34 Y Min Brg Width Req= - BCDL: 10.00 Category:NA Snow Duration:NA HORZ(LL): 0.000 L - - Bearing Y is a rigid surface. Des Ld: 65.00 J EXP:NA - - HORZ(TL): 0.001 L - - NCBCLL: 10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Maximum Top Chord Forces Per Ply(lbs) Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.067 Chords Tens.Comp. Chords Tens. Comp. Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.017 A-B 0 0 G-H 0 0 Spacing:16.0" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.023 B-C 0 0 H-I 0 0 C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: C-D 0 0 I-J 0 0 I:NA GCpi:NA Plate Type(s): D-E 0 0 J-K 0 0 Wind Duration:NA WAVE VIEW Ver:18.01.00B.0430.21 E-F 0 0 K-L 0 0 Lumber End Vertical Attachment F-G 0 0 Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical Top chord 4x2 SP#2 using(3)qty.10d box or(0.128"x3"min)gun nails,or Maximum Bot Chord Forces Per Ply(lbs) Bot chord 4x2 SP#2 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Chords Tens.Comp. Chords Tens. Comp. Webs 4x2 SP#3 staples,through wide face;or(3)qty. 16-Gauge,1" y-X 0 0 S R 0 0 Crown(minimum),1-1/2"length wire staples on each Lumber value set"13B"uses design values narrow face. X-W 0 0 R-Q 0 0 approved 1/30/2013 by ALSC W-V 0 0 Q-P 0 0 Additional Notes V-U 0 0 P-0 0 0 Bracing See detail STRBRIBR1014 for bracing and bridging U-T 0 0 0-N 0 0 Sheathing is required for any longitudinal(drag) recommendations. T-S 0 0 forces.All connections to be designed by the building Truss must be installed as shown with to chord designer. p u p Maximum Web Forces Per Ply(lbs) Fasten rated sheathing to one face of this frame. The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. 1-8-0. Plating Notes Z-Y 0 -7 L-N 0 -25 All plates are 1.5X3 except as noted. A-Y 0 -35 N-M 0 -7 Purlins Maximum Gable Forces Per Ply(lbs) In lieu of structural panels or rigid ceiling use purlins Gables Tens.Comp. Gables Tens. Comp. to laterally brace chords as follows: B-X 0 98 G S 0 98 Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.25 14.15 B-W 0 -98 G-S 0 -98 BC 120 0.25 14.15 D-V 0 -98 I-Q 0 -97 Apply purlins to any chords above or below fillers E-U 0 -98 J-P 0 -100 at 24"OC unless shown otherwise above. F-T 0 -98 K-O 0 -87 Loading Bottom chord checked for 10.00 psf non-concurrent live load. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11:11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer fit\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No.l 083glowski PErNo 58544 Arneson PE No.71457y APE No.7769311 76238 Ply: 1 SEQN:17466/T12/GABL Custom-Roick Res. Qty: 2 FROM: DRW: GE01 J Wgt:85.4 lbs ... / ... 07/19/2018 6'4' ) 12'6" I6'4" 6'4" I.—2'4"—i–1'4°–{ (TYP) F•14X4 E G D H < 12 i 9 7 C I fo m3X4(B IT)B'' _ 1111111111116. Jm3X4(B1T) 0�. .�.�.�.�.�.� 20'11' .i. ' A R O P • N M L K — I--- 128" 2, ( 128" I 2'- 12'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or•=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL): -0.001 L 999 240 J" 107 /49 /58 /- /22 /151 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):-0.002 L 999 14Wind reactions based on MWFRS BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.003 R - - J Min Brg Width Req= - Des Ld: 40.00 J EXP:D HORZ(TL):0.003 R - - Bearing B Fcperp=565psi. NCBCLL: 10.00 Mean Height:22.95 ft Code/Misc Criteria Creep Factor:2.0 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.772 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.128 Chords Tens.Comp. Chords Tens. Comp. Spacing:24.04 MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.069 A-B 84 0 F-G 140 -58 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: B-C 56 -110 G-H 145 -66 GCpi:0.18 Plate Type(s): C-D 84 -63 H-I 157 -88 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 D-E 82 -53 I-J 127 -123 Lumber Additional Notes E-F 135 58 J-K 84 0 Value Set:13B(Effective 6/1/2013) See DWGS A16030ENC101014&GBLLETIN1014 for Top chord 2x4 SP#3 gable wind bracing and other requirements. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 The overall height of this truss excluding overhang is Chords Tens.Comp. Chords Tens. Comp. Webs2x4SP#3 5-1-14. B-R 287 -138 O-N 296 -143 Lumber value set"13B"uses design values Top Chord overhang(s)may be field trimmed. R-Q 289 -139 N-M 293 -143 approved 1/30/2013 by ALSC 0-P 293 -142 M-L 289 -144 P-O 296 -143 L-J 285 -143 Plating Notes All plates are 3X4 except as noted. Maximum Gable Forces Per Ply(lbs) Plate positions consider a 0.50 inch truss perimeter Gables Tens.Comp. Gables Tens. Comp. edge distance. C-R 86 -124 N-G 120 -99 Purlins D-Q 132 -95 M-H 132 -95 In lieu of structural panels or rigid ceiling use purlins E-P 121 99 L-I 86 124 to laterally brace chords as follows: F-0 20 -154 Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 14.67 BC 75 0.15 12.52 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX TrueHouse PE No 60839 PE No 58544 PE No.71457 PE No.77693 76238 Ply:1 SEQN:17467/T59/GABL Custom-Roick Res. Qty: 1 FROM: DRW: GE02 4, Wgt:33.6 lbs ... / ... 07/19/2018 3' 6' 3' I 3' I--1'4"--I (TYP) I---113"—I D=4X4 ,2 v 9 CilitN& R 1m3X4(B1T)B '' T)i20'11' A ' G J I H F-1, I- 6, 1' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF)I Defl/CSI Criteria ♦Maximum Reactions(lbs),or'=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NAVERT(LL): 0.000 D 999 240 F* 108 /32 /59 /- /22 /72.0 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA WVERT(TL): 0.001 D 999 184yind reactions based on MWFRS BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.001 C - - F Min Brg Width Req= - Des Ld: 40.004, EXP:D HORZ(TL): 0.001 C - - Bearing B Fcperp=565psi. NCBCLL: 10.00 Mean Height:22.07 ft Code/Misc Criteria Creep Factor:2.0 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.171 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.036 Chords Tens.Comp. Chords Tens. Comp. Spacing:24.0 J MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.020 A-B 42 0 D-E 73 -53 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: B-C 26 -49 E-F 59 -59 GCpi:0.18 Plate Type(s): C-D 77 -53 F-G 42 0 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 Lumber Additional Notes Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) See DWGS A16030ENC101014&GBLLETIN1014 for Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#3 gable wind bracing and other requirements. B-J 120 -59 I-H 127 -63 Bot chord 2x4 SP#3 The overall height of this truss excluding overhang is J-I 127 -63 H-F 118 -63 Webs 2x4 SP#3 2-7-14. Lumber value set"13B"uses design values Top Chord overhang(s)may be field trimmed. Maximum Gable Forces Per Ply(lbs) approved 1/30/2013 by ALSC Gables Tens.Comp. Gables Tens. Comp. Plating Notes C-J 127 -104 H-E 127 -104 All plates are 3X4 except as noted. D-I 6 -99 Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.00 7.00 BC 68 0.15 5.85 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (ill) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 AV\ 1rueHouse PE No.l 08391owski Jeffrey 58544 Arneson Derek No 71457y APE No.Russell APEX 76238 Ply: 1 SEQN: 17475/T50/GABL Custom-Roick Res. Qty: 1 FROM: DRW: GE03 J Wgt:245.0 lbs Page 1 of 2 ... / ... 07/19/2018 e 94' I 12'814 I 1601 I 194'15 I22'8'2 I 261 I 318'13 `(•' 366 '(' 9'4' 34'14 33'2 34'14 73'2 34'14F 5'4'4 4'9'4 19'8'8 I 4' I.-2'6'4+ (N ) M,3%4(..) 13X4(..H \p \P 12 E \Q 025 7 D/ A 3X4(") AE QAF„1G'N Nisi„ L B/. W 4 -68'12 .4X4 14Xli)Q IloT SXS�J N m3X4(81)A/ - - `� Q 3X4(81) ..-----------------------:-.A-----------------------------110'1'2 V U T AD AC AB AA Z Y X W .5X5(") =4X4 4X4 �5%5(") C 36'6' 1 02'4 I 3'3'2 i 3414 I 318'6 I 34'14 I 3'4'14 I 10'118 9'2'4 12'5'6 15'10'5 19'6'11 22'11'10 26'4'8 366' Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSE) DefUCSI Criteria ♦Maximum Reactions(lbs),or'=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.203 M 999 240 A. 94 /34 /54 /_ /36 /222 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA J VERT(TL): 0.673 M 487 180.5 358 /56 /267 /- /- /6.5 BCDL:_ Risk Category:II Snow Duration:NA HORZ(LL): 0.192 M - ArX /181 Des Ld: 40.00 4 EXP:D HORZ(TL): 0.398 M - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.668 S Min Brg Width Req= 1.5 Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.990 Bearings A&S Fcperp=565psi. Spacing:16.0"-I MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.902 �/ C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 A-B 273 -437 J-K 1791 -1349 Lumber Wind B-C 223 -355 K-L 1803 -1357 Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C D-E 2129 -279 L-N 4040 -2310 Topchord 2x4 SP#2 member design. D-E 191 -279 M-O 140 150 E-F 171 -231 0-P 157 -198 Bot chord 2x4 SP#2 F-H 143 -166 P-Q 163 -228 Webs 2x4 SP#3:W4 2x4 SP#1: Additional Notes See DWGS A16015ENC101014&GBLLETIN1014 for G I 463 -298 Q R 130 221 Lumber value set"13B"uses design values gable wind bracing and other requirements. I-J 1812 -1362 R-S 191 -364 approved 1/30/2013 by ALSC The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Plating Notes 9-3-14. Chords Tens.Comp. Chords Tens. Comp. All plates are 3X4 except as noted. - (")6 plate(s)require special positioning.Refer to A-AD 347 -206 Y-X 685 615 scaled plate plot details for special positioning AD-AC 352 -210 X-W 823 -909 requirements. AC-AB 353 -211 W-V 3612 -4271 Plate positions consider a 0.50 inch truss perimeter AB-AA 354 -212 V-U 758 868 edge distance. AA-Z 355 -213 U-T 491 -145 Z-Y 356 -214 T-S 246 -76 Purlins In lieu of structural panels or rigid ceiling use puffins Maximum Web Forces Per Ply(lbs) to laterally brace chords as follows: Webs Tens.Comp. Webs Tens. Comp. Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 36.50 G-Y 144 -61 U-N 707 -1007 BC 29 0.15 36.35 G-H 125 -111 M-AE 131 -123 Apply purlins to any chords above or below fillers G-X 376 -488 N-T 192 -39 at 24"OC unless shown otherwise above. X-I 513 -341 AE-N 191 -167 I-W 1088 -1385 AE-AF 257 -208 Loading W-J 118 -198 T-R 184 -188 Bottom chord checked for 10.00 psf non-concurrent K-V 74 -114 AF-AG 255 -207 live load. V-L 1154 -1567 AG-AH 254 -205 Truss designed for unbalanced load using 0.00/1.00 L-U 490 -351 AH-R 256 -207 windward/leeward factors. Maximum Gable Forces Per Ply(lbs) Gables Tens.Comp. Gables Tens. Comp. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TFH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer if*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No l 08391owski PErNo 58544 Arneson PE No 71457y FE No.7769311 76238 Ply: 1 SEQN:17475/T50/GABL Custom-Roick Res. Qty: 1 FROM: DRW: GE03 Wgt:245.0 lbs Page 2 of 2 ... / ... 07/19/2018 B-AD 125 -106 F-Z 90 -72 C-AC 48 -48 AF-O 70 -56 D-AB 61 -59 AG-P 38 -34 E-AA 66 -57 AH-Q 31 -25 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (1:11'1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No l 08391owski PErNo 58544son PE No.71457PE No.77y A69311 76238 Ply:1 SEQN:17486/T10/GABL ' Custom-Roick Res. Qty: 1 FROM: DRW: GE04 J Wgt:231.0 lbs Page 1 of 2 ... / ... 07/19/2018 r4 52'10 I6'6'�1 ' I 122'15I 155'5I 184'4 ( 2010' I 23'7'4 ) 26'1' I 31'112 36'6' )52'10 131 2 2'10'15 32'7 2'10'15 2'512 294 2'512 5'012 54"4 LI DT7'7'14I - 13X4(") 13X4("F D/ 12 C/ < ti 10.25 •13,:•••„/-V Z AA X4(••) N � c /- V m - .. •4X4 a5X5(") •4X4 ./...:. E G H I J K • �z •3X4(81)A• - 1.E , _\ />'NO 3X4(81) 10'1"2 X W V U S R 0 P •H0510(-) '=5X7 •5X5(") •4X4 1 18.4"4 1 18'1"12 1 505 _( 4'1'15 ( 2712 I 3.3.9 ) 3'0'11 ) 2'7'8 I 2'9'4 I 2'5'12 I 411' I 54'4 I 5.0'5 9'2'4 12' 15.3'9 18'4'4 20'11'12 239' 26'2'12 31'1'12 36'6- Loading Criteria(est) Wind Criteria 'Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA 4,VERTU): 0.156 G 999 240 A 491 /96 /265 /- /676 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.573 G 646 18 T 1155 /474 /596 /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.132 F - 4/ 0 480 /86 /272 /- /- /- Des Ld: 4 EXP:D HORZ(TL): 0.277 F - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.903 T Min Brg Width Req= 1.5 Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.972 0 Min Brg Width Req= - MWFRS Parallel Dist:h/2 to h RepFactors Used:Yes Max Web CSI: 0.999 Bearings A&T Fcperp=S65psi- Spacing:16.0"it MWFRS C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): ' Chords Tens.Comp. Chords Tens. Comp. ' Wind Duration:1.60 WAVE,HS VIEW Ver:18.01.00B.0430.21 Lumber Loading A-8 230 -603 H-I 807 -437 B-C 108 -182 I-J 807 -437 Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent C-D 123 -178 J-K 693 -792 Topchord 2x4 SP#2 live load. D-F 108 -131 K-M 718 -827 Bot chord 2x4 SP#2 Truss designed for unbalanced load using 0.00/1.00 E-G 649 -892 L-N 167 -208 Webs 2x4 SP#3 windward/leeward factors. G-H 627 -868 N-O 225 -588 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Additional Notes See DWGS A16015ENC101014&GBLLETIN1014 for Maximum Bot Chord Forces Per Ply(lbs) Plating Notes gable wind bracing and other requirements. Chords Tens.Comp. Chords Tens. Comp. All plates are 3X4 except as noted. The overall height of this truss excluding overhang is A-X 818 -557 T-S 636 -215 (")6 plate(s)require special positioning.Refer to 9-3-14. X-W 1869 -1429 S-R 669 236 scaled plate plot details for special positioning W-V 1925 -1480 R-Q 1532 -998 requirements. V-U 947 -647 Q-P 1508 -863 Plate positions consider a 0.50 inch truss perimeter U-T 918 -634 P-O 399 92 edge distance. Maximum Web Forces Per Ply(lbs) Purlins Webs Tens.Comp. Webs Tens. Comp. In lieu of structural panels or rigid ceiling use purlins B-X 409 -264 H-T 1153 1661 to laterally brace chords as follows: g-Y 139 -138 I-T 127 70 Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 36.50 B-E 504 -552 T-J 989 -1522 BC 60 0.15 36.38 X-E 1008 -1250 J-S 330 -199 Apply purlins to any chords above or below fillers Y-Z 138 -138 K-R 248 -160 at 24"OC unless shown otherwise above. Z-AA 139 -138 R-M 829 -1036 E-W 155 -48 L-M 173 -160 Hangers/Ties E-V 913 -1034 M-Q 172 -46 (J)Hanger Support Required,by others AA-E 159 -133 M-P 914 -1134 AA-F 116 -99 M-N 397 -488 Wind V-G 220 -147 P-N 345 -207 Wind loads based on MWFRS with additional C&C U-H 304 -194 member design. Maximum Gable Forces Per Ply(lbs) Gables Tens.Comp. Gables Tens. Comp. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. (Tv.11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No l 08391owskirey P No 58544 Arneson PEDerePENo Murray7457PE No.7769311 76238 Ply: 1 SEAN:17486/T10/GABL Custom-Roick Res. Qty: 1 FROM: DRW: GE04 4/ Wgt:231.0 lbs Page 2 of 2 ... / ... 07/19/2018 C-Y 6 -12 D-Z 64 -52 NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (114'1-1 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No.Michael 08391owski Jeffrey 58544 Arneson PE PE No. Murray1457PE No.7769311 76238 Ply:1 SEQN: 17477/T27/GABL Custom-Roick Res. Qty: 1 FROM: DRW: GE05 1/ Wgt:184.8 lbs Page 1 of 2 ... / ... 07/19/2018 I 12' I 24' I 12' 12' I-2'e•—I (TVP) J.4x4 _ D Hill\ 5X50:/ 111.N.5.5N,.-} //Fee .iiEwnwiz .. \P \O .3x4(B1T)B' l• I'I I I �3Xd(BiT) _ 71 ���� 6610 A I' U S AE AD AC AB AA Z V X W V T •5X5(..) I 24' I 24' F16 I 24' I 1'61...1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or*=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NAVERT(LL): 0.008 J 999 240 R' 102 /29 /52 /- /16 /288 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA V VERT(TL): 0.017 J 999 227 Wind reactions based on MWFRS BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.009 G - 4/ R Min Brg Width Req= - Des Ld: 40.00 1/ EXP:D HORZ(TL): 0.010 G - - Bearing B Fcperp=565psi. NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.394 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.349 Chords Tens.Comp. Chords Tens. Comp. Spacing:24.0 J MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.200 A-B 63 0 J-K 175 -161 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: B-C 150 -284 K-L 128 -191 GCpi:0.18 Plate Type(s): C-D 126 -197 L-M 72 -161 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 D-E 102 -176 M-N 3 -173 Lumber Loading E•F 78 -174 N-O 0 178 F-G 61 -173 O-P 0 -217 Value Set:13B(Effective 6/1/2013) At Truss passed check for 20 psf additional bottom G-H 72 -161 P-Q 0 -249 Top chord 2x4 SP#3 chord live load in areas with 42"-high x 24"-wide H-I 128 191 Q-R 0 319 Bot chord 2x4 SP#2:B2 2x4 SP#3: clearance. I-J 175 -161 R-S 63 0 Webs 2x4 SP#3 At Bottom chord checked for 10.00 psf non-concurrent Lumber value set"13B"uses design values live load. approved 1/30/2013 by ALSC Truss designed for unbalanced load using 0.00/1.00 Maximum Tens.Comp.Bot Chord Forces Per Ply(lbs) windward/leeward factors. Chords Chords Tens. Comp. Plating Notes B-AE 371 -193 Y-X 384 -202 All plates are 3X4 except as noted. Additional Notes AE-AD 376 -195 X-W 383 0 (")3 plate(s)require special positioning.Refer to See DWGS A16015ENC101014&GBLLETIN1014 for AD-AC 379 -197 W-V 0 scaled plate plot details for special positioning gable wind bracing and other requirements. AC AB 381 -198 V-U 380 0 requirements. The overall height of this truss excluding overhang is AB-AA 383 -199 U-T 377 0 Plate positions consider a 0.50 inch truss perimeter 9-4-14. AA-Z 384 -200 T-R 372 0 edge distance. Top Chord overhang(s)may be field trimmed. Z-Y 383 -201 Purlins Maximum Web Forces Per Ply(lbs) In lieu of structural panels or rigid ceiling use purlins Webs Tens.Comp. Webs Tens. Comp. to laterally brace chords as follows: AF-AG 8 0 AH-AI 10 1 Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 25.50 AG-AH 10 -1 Al-AJ 8 -1 BC 120 0.15 23.85 Apply purlins to any chords above or below fillers Maximum Gable Forces Per Ply(lbs) at 24"OC unless shown otherwise above. Gables Tens.Comp. Gables Tens. Comp. Wind C-AE 135 -135 Al-K 67 -40 Wind loads based on MWFRS with additional C&C D-AD 92 -85 AJ-Y 104 -158 member design. E-AC 97 -87 AJ-L 91 -141 F-AB 97 -86 X-M 103 -71 G-AA 103 -71 W-N 97 -86 H-AF 91 -141 V-O 97 -87 AF-Z 104 -158 U-P 92 -85 I-AG 66 -40 T-Q 135 -135 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,f*/\ APEX T'rueHouse PE No Michael 08391owskiJeffrey No 58544 Arneson PEPE No. Murray1457PE No.7769311 76238 Ply:1 SEQN:17477/T27/GABL Custom-Roick Res. Qty: 1 FROM: DRW: GE05 Wgt:184.8 lbs Page 2 of 2 ... / ... 07/19/2018 J-AH 42 -106 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03. should be used in conjunction with the architectural plans during installation. (11'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Jg*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Tru eHo u se PE No Michael 08391owskiJeffrey No 58544 on PEPE No.71457Derek B y APE No.dam K Russell APEX 76238 Ply:1 SEAN:17489/T2/GABL Custom-Roick Res. Qty: 1 FROM: DRW: GE06 Wgt:133.0 lbs ... / ... 07/19/2018 I 4'4'3 9'9' 12' 19'6' 4.4.3 I 54.13 I 2'3' 1 Ts' 1 1-1'9'-I-1.4:-I F--2'6'-.I (TYP) -r li5x5(•') :2 T cn / PO ' N 012 M - r 19'6' i 2 12' 76 12' I 19'6' I 2' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf i SF Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA I VERT(LL): 0.285 DI 807 240 a 1048 /304 /651 /- /358 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.804 0 423 18ArL 1093 /304 /650 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL: 0.219 E - - Wind reactions based on MWFRS Des Ld: 40.00./ EXP:D HORZ(TL): 0.418 E - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 L Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.808 Bearings B&L Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.857 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.264 Maximum Top Chord Forces Per Ply(lbs) J C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 84 0 G-H 414 -747 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 265 -997 H-I 511 -813 Lumber Loading C-D 275 -939 I-J 522 -799 Value Set:13B(Effective 6/1/2013) Gable end supports 8"max rake overhang.Top E-F 283 - 685 J-K 486 -7461 - chord must not be cut or notched. E-F 288 -685 K-L 393 -1182 Top chord 2x4 SP M-31 :T2 2x4 SP SS: F-G 411 -830 L-M 84 0 :T3 2x4 SP#1: Truss passed check for 20 psf additional bottom Bot chord 2x4 SP#1 :B2 2x4 SP#2: chord live load in areas with 42"-high x 24"-wide Webs 2x4 SP#3 clearance. Maximum Bot Chord Forces Per Ply(lbs) Lumber value set"138"uses design values Bottom chord checked for 10.00 psf non-concurrent Chords Tens.Comp. Chords Tens. Comp. approved 1/30/2013 by ALSC live load. B-Q 705 -236 O-N 825 -89 Plating Notes Truss designed for unbalanced load using 0.00/1.00 Q-P 705 -234 N-L 819 -90 windward/leeward factors. P-0 694 -234 All plates are 3X4 except as noted. (")2 plate(s)require special positioning.Refer to Additional Notes Maximum Web Forces Per Ply(lbs) scaled plate plot details for special positioning See DWGS A16015ENC101014&GBLLETIN1014 for Webs Tens.Comp. Webs Tens. Comp. requirements. gable wind bracing and other requirements. Plate positions consider a 0.50 inch truss perimeter The overall height of this truss excluding overhang is 0-R 179 -388 I-U 694 449 edge distance. 7-8-10. R-S 176 -235 U-V 188 -461 Top Chord overhang(s)may be field trimmed. S T 180 268 NV-K 195 396 Purlins T-U 243 -214 N-K 388 0 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Gable Forces Per Ply(lbs) Chord Spacing(in oc) Start(ft) End(ft) Gables Tens.Comp. Gables Tens. Comp. TC 24 -2.00 21.50 BC 120 0.15 19.35 C-Q 59 -27 G-S 63 -19 Apply purlins to any chords above or below fillers D-P 158 -300 H-T 157 -213 at 24"OC unless shown otherwise above. E-O 546 -158 J-V 45 -182 F-R 207 -361 Wind Wind loads based on MWFRS with additional C&C member design. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (116'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ig*/\ TrueHouse PE NoMichael l 08391awskiJeffrey No 58544 on PEPE No MurrayDerek B7457Adam K PE No.77693 Russell APEX 76238 Ply: 1 SEQN:17479/T5/GABL ' Custom- oick Res. Qty: 1 FROM: DRW: GE07 Wgt:128.8 lbs ... / ... 07/19/2018 I 16'8° I 8'4° 16"—}-1,1°-{ (TVP) Hm4X4 _ 7ilIlIlIiIIIII \ lBlfl 6610Z Y X W V U T S R 0 P O v 5X5(") I 16'8° 'I 2' I 16'8" I 2'-I 16'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs),or.=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA &VERT(LL): 0.001 H 999 240 N' 102 /32 /56 /- /19 /199 • BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.002 H 999 180 Wind reactions based on MWFRS BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.002 G - J N Min Brg Width Req= - Des Ld: 40.00 J EXP:D HORZ(TL): 0.003 G - - Bearing B Fcperp=565psi. NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.409 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.163 Chords Tens.Comp. Chords Tens. Comp. Spacing:24.0 J MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.093 A-B 84 0 H-I 192 -45 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: B-C 83 -135 I-J 124 -44 GCpi:0.18 Plate Type(s): C-D 122 -97 J-K 109 -62 Wind Duration: 1.60 WAVE VIEW Ver:18.01.008.0430.21 D-E 95 -64 K-L 112 -81 Lumber Wind E-F 93 -46 L-M 138 -113 Value Set:138(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C F-G 124 -40 M-N 184 151 member design. G-H 192 -45 N-O 84 0 Top chord 2x4 SP#2 Bot chord 2x4 SP#3 Additional Notes Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 Lumber value set"138"uses design values See DWGS A16015ENC101014&GBLLETIN1014 for Chords Tens.Comp. Chords Tens. Comp. approved 1/30/2013 by ALSC gable wind bracing and other requirements. B-Z 274 -184 U-T 282 -190 The overall height of this truss excluding overhang is Z-Y 271 -181 T-S 282 -201 Plating Notes 6-7-14. Y-X 275 -185 S-R 280 -200 All plates are 3X4 except as noted. Top Chord overhang(s)may be field trimmed. X-W 278 -187 R-Q 277 -198 (")1 plate(s)require special positioning.Refer to W V 280 188 Q P 273 194 scaled plate plot details for special positioning V-U 282 -190 P-N 275 -197 requirements. Plate positions consider a 0.50 inch truss perimeter Maximum Gable Forces Per Ply(lbs) edge distance. Gables Tens.Comp. Gables Tens. Comp. Purlins C-Z 75 -92 T-I 101 -99 In lieu of structural panels or rigid ceiling use purlins D-Y 116 99 S-J 101 85 to laterally brace chords as follows: E-X 95 85 R-K 95 85 Chord Spacing(in oc) Start(ft) End(ft) F-W 101 -85 Q-L 116 -99 TC 24 -2.00 18.67 G-V 101 -99 P-M 74 -92 BC 75 0.15 16.52 H-U 0 -169 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: Nir 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. (Flivi) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if"\ APEX TrueHouse PE No 108391owski Jeffrey No 585445on PEFE No.71457y APE No.77693 Russell9 76238 Ply: 1 SEQN:17480/T40/GABL Custom-Roick Res. Qty: 1 FROM: DRW: GE08 J Wgt:85.4 lbs ... / ... 07/19/2018 6'10" I 13'8" el 0" 6'10" I-210"-I--1'4"--1 (TYP) Fa4X4 I Ai zo m 12w3X4(B1TI I_ i : : :- _. . Vzo 101"p PP" R N LA K I 13'8" I~2• I 13'8" I 2' 13'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or•=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA i VERT(LL):-0.001 L 999 240 J` 105 /33 /58 /- /21 /164 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA lir VERT(TL):-0.002 L 999 180 Wind reactions based on MWFRS BCDL: 10.00 a Risk Category:II Snow Duration:NA HORZ(LL):-0.003 C - J J Min Brg Width Req= - Des Ld: 40.00 Alr EXP:D HORZ(TL): 0.003 C - - Bearing B Fcperp=565psi. NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.735 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.133 Chords Tens.Comp. Chords Tens. Comp. Spacing:24.0"J MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.080 A-B 84 0 F-G 139 -70 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: B-C 68 -106 G-H 146 -69 GCpi:0.18 Plate Type(s): C-D 75 -79 H-I 159 -89 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 D-E 80 -65 I-J 143 -129 Lumber Additional Notes E-F 133 70 J-K 84 0 Value Set:13B(Effective 6/1/2013) See DWGS A16015ENC101014&GBLLETIN1014 for Top chord 2x4 SP#3 gable wind bracing and other requirements. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 The overall height of this truss excluding overhang is Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 5-6-6. B-R 270 -140 0-N 279 -146 Lumber value set"13B"uses design values Top Chord overhang(s)may be field trimmed. R-Q 273 -142 N-M 276 -146 approved 1/30/2013 by ALSC Q-P 276 -144 M-L 274 -146 Plating Notes P-O 279 -146 L-J 269 -145 All plates are 3X4 except as noted. Maximum Gable Forces Per Ply(lbs) Plate positions consider a 0.50 inch truss perimeter Gables Tens.Comp. Gables Tens. Comp. edge distance. C-R 113 -150 N-G 109 -100 Purlins D-Q 114 -88 M-H 113 -88 In lieu of structural panels or rigid ceiling use purlins E-P 109 -100 L-I 113 150 to laterally brace chords as follows: F-0 25 -155 Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 15.67 BC 75 0.15 13.52 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (ill) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,t\ APEX TrueHouse PE Michael G83 Kozlowski Jeffrey 8544 Arnesondam K PE PE No.71457y APE No.Russell l 76238 Ply:1 SEQN:17481/T3/GABL Custom-Roick Res. Qty: 1 FROM: DRW: GE09 Wgt:33.6 lbs ... / ... 07/19/2018 e 24113'8'8 4'10'8 I 2.4'8 1 1'4" ' 1'2' ' E 13X4(") — — II12 C9 , a m3X4(B1T)BAlii -mi I — 88'10 ' F A H G 13X4(") f' S'0„e 'I 2'4.8 14— 16 2.4.6 1 3.8.8 I 4'10°8 1 56'8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or'=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA JVERT(LL):-0.000 H 999 240 F* 106 /33 /86 /- /40 /60.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.001 H 999 180 Wind reactions based on MWFRS BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.003 E - 4/ F Min Brg Width Req= - Des Ld: 40.004 EXP:D HORZ(TL): 0.003 E - - Bearing B Fcperp=565psi. NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.441 Maximum Top Chord Forces Per Ply(lbs) Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.084 Chords Tens.Comp. Chords Tens. Comp. Spacing:24.0” J MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.037 A-B 63 0 C-D 49 -124 C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: B-C 62 -205 D-E 24 -40 GCpi:0.18 Plate Type(s): Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 Maximum Bot Chord Forces Per Ply(lbs) Lumber Wind Chords Tens.Comp. Chords Tens. Comp. Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C B-H 327 -121 G-F 336 -125 Top chord 2x4 SP#3 member design. H-G 332 -123 Bot chord 2x4 SP#3 Right end vertical not exposed to wind pressure. Webs 2x4 SP#3 Maximum Gable Forces Per Ply(lbs) Lumber value set"13B"uses design values Additional Notes Gables Tens.Comp. Gables Tens. Comp. approved 1/30/2013 by ALSC See DWGS A16015ENC101014&GBLLETIN1014 for gable wind bracing and other requirements. C-H 130 -124 E-F 53 -40 Plating Notes The overall height of this truss excluding overhang is D-G 131 -98 All plates are 3X4 except as noted. 4-2-4. (")2 plate(s)require special positioning.Refer to Top Chord overhang(s)may be field trimmed. scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 5.04 BC 59 0.15 5.04 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11.111rH111-) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer ,"\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX 1'rueHouse PE No.l 0838lowski PC No.58544 on PE No. Murray7457APE No.Russell , , 76238 Ply: 1 SEQN:17463/T48/GABL Custom-Roick Res. Qty: 2 FROM: DRW: GE10 J Wgt:102.2 lbs ... / ... 07/19/2018 rs°s I 810" 51°n I 178' 2'6"5 6'3'11 6'3"11 2'6"5 I~2711-.I'1'4"+I (TVP) F III4X5(R) T 0-1- ih )B1T)4lILç :1711" ' R D P • N M m A K _ 1 7 r. - -� 16'2"2 1`2,6"5 • 12.7"5 1 2'6"5-.I I 265 I 1275 I Z 3B 2'6'5 15'1'11 z� ' I I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or*=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL): 0.001 F 999 240 A 95 /153 /174 /- /235 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.001 R 999 180 B* 104 /39 /67 /- /- /151 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.003 H - 4/ S 95 /60 /56 /- /- /6.5 Des Ld: 40.00 J EXP:D HORZ(TL): 0.004 H - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:19.91 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.065 B Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.038 S Min Brg Width Req= 1.5 Spacing:24.0 MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.052 Bearing B is a rigid surface. " Bearings A&S Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 Chords Tens.Comp. Chords Tens. Comp. Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C B-C 12 -254 -G 202 -64 member design. B-C 1255 -154 GG-H 139 -41 Top chord 2x6 SP#2 C-D 124 •127 H-I 72 -41 Bot chord 2x4 SP#2 D-E 139 -108 I-J 27 -68 Webs 2x4 SP#3 Additional Notes Lumber value set"13B"uses design values See DWGS A16030ENC101014&GBLLETIN1014 for E-F 202 87 J-K 72 57 approved 1/30/2013 by ALSC gable wind bracing and other requirements. The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Plating Notes 7-0-8. Chords Tens.Comp. Chords Tens. Comp. All plates are 3X4 except as noted. B-R 160 -85 O-N 178 -82 Plate positions consider a 0.50 inch truss perimeter R-Q 169 84 N-M 175 80 edge distance. Q-P 175 -83 M-L 169 -78 P-O 178 -82 L-J 160 -72 Purlins In lieu of structural panels or rigid ceiling use puffins Maximum Gable Forces Per Ply(lbs) to laterally brace chords as follows: Gables Tens.Comp. Gables Tens. Comp. Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.53 15.14 C-R 122 -89 N-G 94 -95 BC 75 0.15 12.47 D-Q 104 -83 M-H 104 -83 Apply puffins to any chords above or below fillers E-P 94 -95 L-I 122 -89 at 24"OC unless shown otherwise above. F-O 52 -167 Loading Gable end supports 8"max rake overhang.Top chord must not be cut or notched. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. ( IJ.J'I) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi'/\ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX 1ueHouse PE No 60839 PE No 58544 PE No 71457 PE No.77693 76238 Ply:1 SEQN: 17450/T34/HIP_ Custom-Roick Res. Qty: 4 FROM: DRW: HJ01 Wgt:15.4 lbs ... / ... 07/19/2018 C T 11'10"4 12 o 6.76 V 3X4(B1T) B 5"2 M 10'1"2 A 2'10"11 2'8"9 21011 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA JVERT(LL):NA B 211 /134 /352 /- /122 /9.0 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA J D 39 /20 /28 /- /- /1.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.004 D - - C 6 /43 /50 /- /- /1.5 Des Ld: 40.00 J EXP:D HORZ(TL): 0.005 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.831 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.324 C Min Brg Width Req= - MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0 J C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 Lumber A-B 45 0 B-C 30 -35 Value Set:13B(Effective 6/1/2013) Top chord 2x4 SP#2 Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.71 2.89 BC 33 0.15 2.89 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 2-0-10. Top Chord overhang(s)may be field trimmed. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. OH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi'/\ 7z'ueHouse Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX PE No.60839 PE No.58544 PE No.71457 PE No.77693 76238 Ply:1 SEQN:17430/T31/EJAC Custom-Roick Res. Qty: 4 FROM: DRW: J014f Wgt:11.2 lbs ... / ... 07/19/2018 C (1))�( 11'11'4 i 0 12 =3X4(B1T = 10.25 7 B N 2M1111.11110 1 in 10'1"2 ►� f► D A -. 1'9"5 I- 2' H Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA j VERT(LL):NA B 291 /73 /273 /- /123 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA J D 27 /16 /27 /- /- /1.5 BCDL:_ Risk Category:II Snow Duration:NA HORZ(LL):-0.002 D - - C 58 /36 /49 /- /- /1.5 Des Ld: .rli: r EXP:D HORZ(TL): 0.003 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.660 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.127 C Min Brg Width Req= - Spacing:24.0"♦ MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. �/ C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): • Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 Lumber Additional Notes A-B 83 0 B-C 37 -72 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Top chord 2x4 SP#3 2-1-10. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.78 2.00 BC 22 0.15 2.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. (glii 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if"\ APEX TrueHouse ,PEichNaoe.16008K3o9zIowski PErNo 58544 on PE No.71457y PE No.7769311 76238 Ply:1 SEQN:17431/T37/EJAC Custom-Roick Res. Qty: 1 FROM: DRW: J02 4/ Wgt:7.0 lbs ... / ... 07/19/2018 B 12 �� 011'11"4 10.25 7 0 3X4(81)q N �, 1� 10,1"2 2' 2' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Lac R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA A 93 /- /54 /- /70 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA d VERT(TL):NA 4' C 37 /1 /23 /- /- /1.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.001 B - - B 58 /57 /58 /- /- /1.5 Des Ld: 40.00 At EXP:D HORZ(TL): 0.001 B - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.111 C Min Brg Width Req= - - Load Duration: 1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.063 B Min Brg Width Req= MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI: 0.000 Bearing A Fcperp=565psi. Spacing:24.0' C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 Lumber A-B 37 -70 Value Set:138(Effective 6/1/2013) Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#3 Chords Tens.Comp. Bot chord 2x4 SP#3 Lumber value set"13B"uses design values A-C 0 0 approved 1/30/2013 by ALSC Plating Notes Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 2.00 BC 22 0.15 2.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The overall height of this truss excluding overhang is 2-1-10. NOTES: I.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ APEX TrueHouse PE No Michael 60839 G Kozlowski 0 39lowskiJeffrey No 58544 Arneson PEPE No.71457y APE No.Russell 76238 Ply:1 SEQN: 17432/T33/JACK Custom-Roick Res. Qty: 15 FROM: DRW: J03 4/ Wgt:16.8 lbs ... / ... 07/19/2018 C h 0 13'2"8 v 12 ',1- i09V co a 3X4(B1T) B v T J° li (t) 10'1"2 ►� A 2' 4' -1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL):NAB 358 /72 /298 /- /179 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA / D 68 /3 /47 /- /- /1.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.003 D - - C 116 /86 /72 /- /- /1.5 Des Ld: .4EXP:D HORZ(TL): 0.006 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code!Misc Criteria Creep Factor:2.0 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.804 D Min Brg Width Req= - - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.245 C Min Brg Width Req= Spacing:24.0 J MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver:18.01.00B.0430.21 Lumber Additional Notes A-B 84 0 B C 69 -101 Value Set:138(Effective 6/1/2013) The overall height of this truss excluding overhang is Top chord 2x4 SP#3 3-4-14. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#3 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 4.00 BC 46 0.15 4.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Iir'FI) �� 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX TrueHouse PE No 60839 PE No.58544 PE No.71457 PE No.77693 76238 Ply:1 SEQN:17453/T30/JACK • Custom-Roick Res. Qty: 3 FROM: DRW: J0441 Wgt:19.6 lbs ... / ... 07/19/2018 2'3"10 4' 2'3"10 I 1'8"6 04X40*) D i cc. - 111'11"4 112 -3X4(81 T) H81'4"14 _� 9 I/ B N N 1�1 c� 10'1"2 1113X4 F E A 25"6I 0 2' 5,6 1- 4, '� 2, Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL): 0.026 C 999 240 B 415 /200 /- /- /- /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.082 C 856 180 E 128 /48 /- /- /- /1.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.020 C - �D 109 /51 /- /- /- /1.5 Des Ld: 40.00 4/ EXP:D HORZ(TL): 0.042 C - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.707 E Min Brg Width Req= - - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.771 D Min Brg Width Req= Spacing:24.0 MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.072 Bearing B Fcperp=565psi. "4, C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 Lumber Loading A-B 84 -41 C D 0 0 Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent B-C 56 -100 Top chord 2x4 SP#3 live load. Bot chord 2x4 SP#3 Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 Wind Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values Wind loads and reactions based on MWFRS. B-F 20 -7 F-E 0 0 approved 1/30/2013 by ALSC Additional Notes Special Loads The overall height of this truss excluding overhang is Maximum Web Forces Per Ply(lbs) (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) 2-1-10. Webs Tens.Comp. TC:From 65 plf at -2.00 to 65 plf at 4.00 Top Chord overhang(s)may be field trimmed. C-F 67 -73 BC:From 5 plf at -2.00 to 5 plf at 0.00 BC:From 20 plf at 0.00 to 20 plf at 4.00 TC: 64 lb Conc.Load at 2.31 BC: 66 lb Conc.Load at 2.31 Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 4.00 BC 46 0.15 4.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11:11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ APEX TrueHouse MPE No l 0838lowski Jeffrey No 585445on FEPE No. Murray1457APE No.Russell 69311 76238 Ply:1 SEQN: 17442/T29/JACK Custom-Roick Res. Qty: 6 FROM: DRW: J05 4/ Wgt:28.0 lbs ... / ... 07/19/2018 C 15'5"8 12 g 7 n m3X4(B1T)B 10'1'2 D A I -2' 7, Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA B 479 /30 /357 /- /198 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA V VERT(TL):NA V D 156 /- /78 /- /- /1.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.017 D - - C 204 /112 /164 /- /- /1.5 Des Ld: 40.00 4/ EXP:D HORZ(TL): 0.031 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.840 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.406 C Min Brg Width Req= - MWFRS Parallel Dist:h to 2h Re Factors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0 4 P C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver:18.01.0OB.0430.21 Lumber Additional Notes A-B 84 0 B-C 122 -182 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Top chord 2x4 SP#2 5-7-14. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#1 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 7.00 BC 75 0.15 7.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. OH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ig*/\ APEX TrueHouse ,F,FichNaoel6G08K3o9zlowski effPErNo 58544 71457 Arneson PE No. Murray APE No.77693 Russell 76238 Ply:1 SEQN:17434/T26/JACK Custom-Roick Res. Qty: 1 FROM: DRW: J06 4/ Wgt:28.0 lbs ... / ... 07/19/2018 -r .00000>000/r: 15'4'4 _o io N b 1,- 3 L I a 10'1.2 D A I-2' 7. I Loading Criteria(pst) Wind Criteria Snow Criteria(Pg,Pt in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA / VERT(LL):NA B 479 /31 /358 /- /196 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA V D 156 /- /78 /- /- /1.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.017 D - - C 204 /110 /158 /- /- /1.5 Des Ld: 40.00W EXP:D HORZ(TL): 0.031 D - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.840 D Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.406 C Min Brg Width Req= - MWFRS Parallel Dist:h to 2h RepFactors Used:Yes Max Web CSI: 0.000 Bearing B Fcperp=565psi. Spacing:24.0" At MWFRS C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 Lumber Additional Notes A-B 84 0 B-C 122 -178 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is 5-6-10. Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 Chords Tens.Comp. Bot chord 2x4 SP#1 Top Chord overhang(s)may be field trimmed. Lumber value set"13B"uses design values B-D 0 0 approved 1/30/2013 by ALSC Plating Notes Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 7.00 BC 75 0.15 7.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Ir'H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,ft/\ APEX TrueHouse PEi No.l 08391owski JPeffrey 58544 on PE No.71457y PE No.Russell 76238 Ply: 1 SEQN:17435/T28/JACK Custom-Roick Res. Qty: 1 FROM: DRW: J07 Wgt:35.0 lbs ... / ... 07/19/2018 I 47 I 7 I 4'7' 2'5' _4X C') D Ai T_44)_13'7"12 Esi HB21'8 0oo1012 4F E A 48'12 _I 23"4 -1 I�-2, _1 4'8'12 T Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.121 C 678 240 B 467 /58 /370 /- /142 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.394 C 319 180 E 163 /45 /106 /- /- /1.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.095 C - - D 128 /47 /61 /0 /0 /1.5 Des Ld: 40.00 EXP:D HORZ(TL): 0.201 C - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.623 E Min Brg Width Req= - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.749 D Min Brg Width Req= - Spacing:24.0" MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.230 Bearing B Fcperp=565psi. C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs) Wind Duration: 1.60 WAVE VIEW Ver:18.01.008.0430.21 Chords Tens.Comp. Chords Tens. Comp. Lumber Additional Notes A-B 84 0 C-D 0 0 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is B C 50 131 Top chord 2x4 SP#2 3-10-2. Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values B-F 15 -10 F-E 0 0 approved 1/30/2013 by ALSC Plating Notes Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning C-F 176 -118 requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 7.00 BC 75 0.15 7.00 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 6.11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer fi*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 T�rueHouse PE No 1608391o `I Jeffrey 58544 Arneson PEPE No. MurrayDerek B71457Adam K PE No.Russell69 APEX 76238 Ply:1 SEQN:17458/T25/JACK Custom.-Roick Res. Qty: 1 FROM: DRW: J08 J Wgt:29.4 lbs ... / ... 07/19/2018 I- 2'3"10 I 7' _I 2'3"10 4'8"6 4X8(") C D milnillMT 11'11"4 •' 12 -3X4(B1T) HB 4'4"14 79 / B N m i N TI ejjlliIll it Ch O 101'2 III3X4F E A 2'5"6 4'6"10 2' I2,5„6 I 7' --1 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pt in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA If VERT(LL): 0.159 C 517 240 B 542 /266 /- /- /- /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.505 C 247 180 E 143 /39 /- /- /- /1.5 BCDL: 10.00Risk Category:II Snow Duration:NA HORZ(LL): 0.117 C - 4D 200 /102 /- /- /- /1.5 Des Ld: 40.00 J EXP:D HORZ(TL): 0.245 C - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 B Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.859 E Min Brg Width Req= - - Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.848 D Min Brg Width Req= MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI: 0.129 Bearing B Fcperp=565psi. Spacing:24.0"At MWFRS C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 Lumber Purlins A-B 84 -41 C D 0 0 B-C 71 -133 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Top chord 2x4 SP#2 to laterally brace chords as follows: Bot chord 2x4 SP#1 Chord Spacing(in oc) Start(ft) End(ft) Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 TC 24 -2.00 7.00 Chords Tens.Comp. Chords Tens. Comp. BC 75 0.15 7.00 Lumber value set"13B"uses design values Apply puffins to any chords above or below fillers B-F 36 -14 F-E 0 0 approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Special Loads Wind Maximum Web Forces Per Ply(lbs) (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Webs Tens.Comp. Wind loads and reactions based on MWFRS. TC:From 65 plf at -2.00 to 65 plf at 2.30 C-F 104 -120 TC:From 33 plf at 2.30 to 33 plf at 4.37 Additional Notes TC:From 65 plf at 4.37 to 65 plf at 7.00 BC:From 5 plf at -2.00 to 5 plf at 0.00 The overall height of this truss excluding overhang is BC:From 20 plf at 0.00 to 20 plf at 2.31 2-1-10. BC:From 10 plf at 2.31 to 10 plf at 4.37 Top Chord overhang(s)may be field trimmed. BC:From 20 plf at 4.37 to 20 plf at 7.00 TC: 64 lb Conc.Load at 2.31 TC: 58 lb Conc.Load at 4.37 BC: 66 lb Conc.Load at 2.31 BC: 27 lb Conc.Load at 4.37 Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Loading Bottom chord checked for 10.00 psf non-concurrent live load. NOTES: It- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (T11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if"\ APEX 1'rueHouse PE No l 0839lowski Jeffrey No 58rne4son PE No. Murray7457APE No.7 69 II 76238 Ply:1 SEAN: 17762/T9/COMN Custom-Roick Res. Qty: 10 FROM: DRW: PB01 4/ Wgt:40.6 lbs ... / ... 07/19/2018 I 7'2I 4'I0"2 9'1'2 19'81 7"2 4 '3" 4'3" 7"2 C$4X4 12 V _ 0.25 O V V B D A /� i E . . ' '41Q 113X4 7"2 7"2 1 8,6„ 1 -I t7 4'3" 4'3" 7"2I ��:� 4'102 I 9'1"2 19.8"A Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs),or'=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udell IJ# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA 4/VERT(LL):-0.001 F 999 240 A -98 /170 /138 /- /99 /4.8 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.002 F 999 180 B• 85 /48 /54 /- /- /102 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.002 F - y,E -98 /106 /104 /- /- /4.8 Des Ld: 40.004/ EXP:D HORZ(TL): 0.002 F - - A /145 NCBCLL: 10.00 Mean Height:18.31 ft Code/Misc Criteria Creep Factor:2.0 B /155 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.303 D /122 Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.174 Wind reactions based on MWFRS Spacing:16.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.015 A Min Brg Width Req= 1.5 B Min Brg Width Req= - C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: E Min Brg Width Req= 1.5 GCpi:0.18 Plate Type(s): Bearings A,B,&E are a rigid surface. Wind Duration:1.60 WAVE VIEW Ver: 18.01.008.0430.21 Lumber Additional Notes Maximum Top Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#3 16-0-3. A-B 191 -165 C-D 121 -142 Bot chord 2x4 SP#3 B-C 121 -142 D-E 76 -86 Webs 2x4 SP#3 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Chords Tens.Comp.m Bot Chord Forces Per Tens.s) Chords Chords Tens. Comp. Plating Notes B-F 66 -26 F-D 66 -26 All plates are 3X4(B1T)except as noted. Plate positions consider a 0.50 inch truss perimeter Maximum Web Forces Per Ply(lbs) edge distance. Webs Tens.Comp. Purlins C-F 18 -51 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -0.42 8.92 BC 99 0.15 8.35 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (16'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 /ft\ APEX TrueHouse PE No.Michael 60839 1owskiJeffrey No 58544 Arneson PEPE No. Murray71457APE No.Russell 76238 Ply:1 SEQN:17495/T65/COMN Custom-Roick Res. Qty: 2 FROM: DRW: T01 J Wgt:88.9 lbs ... / ... 07/19/2018 2'5"9 7'10" 126"9 14713 169" f• 2'5"9 A5.4"7 I 4'10"9 I 1'11.3 I 2'1°3 'I C, 5X5("") ',N., T Nin 12 10.25 7 AI !4X4(81)B 14x4 D\5X7(") E 3X4F r AilliZi L$2011'p `-�■ W5 �, Il3X8 H 15X50 n w4X4 A _L i - - 18'11'14 1 169" 1 2,5„9 I 5'8„7 I 87" 2'5"9 82" 169" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF)I Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA i VERT(LL): 0.229 I 865 240 A 732 /212 /395 /- /238 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.760 I 401 1801/G 714 /220 /399 /- /- /- BCDL: 10.00Risk Category:II Snow Duration:NA HORZ(LL): 0.214 G - - Wind reactions based on MWFRS Des Ld: 40.00 J EXP:D HORZ(TL): 0.462 G - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.76 ft Code/Misc Criteria Creep Factor:2.0 G Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.795 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.973 Spacing:24.0 J MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.465 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 129 -464 D-E 1282 -2677 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 345 -817 E-F 31 -71 Lumber Hangers/Ties C-D 466 -992 Value Set: 13B(Effective 6/1/2013) Recommended hanger connections are based on Top chord 2x4 SP#2:T1 2x6 SP SS Dense: manufacturer tested capacities and calculations. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Conditions may exist that require different Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3:W5 2x6 SP#2: connections than indicated.Refer to manufacturer B-I 689 -243 H-G 1653 804 publication for additional information. Lumber value set"13B"uses design values (J)Hanger Support Required,by others I-H 2859 -1393 approved 1/30/2013 by ALSC Bearing G (16'6",20'11")HTU26 Bracing Supporting Member:(1)2x6 SP#2 Maximum Web Forces Per Ply(lbs) into supporting Webs Tens.Comp. Webs Tens. Comp. (a)Continuous lateral restraint equally spaced on member, member. into supported C-I 508 -150 H-E 1121 -521 member. I-D 1155 -2169 E-G 818 -1674 Plating Notes D-H 296 -478 F-G 71 -92 (")2 plate(s)require special positioning.Refer to Wind scaled plate plot details for special positioning Wind loads based on MWFRS with additional C&C requirements. member design. Plate positions consider a 0.50 inch truss perimeter edge distance. Additional Notes The overall height of this truss excluding overhang is Purlins 7-1-7. In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.46 14.29 BC 74 0.02 14.29 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Trirl) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ APEX TrueHouse MPE Nola 3o9zlowski Jeffrey No 58544son PEPE No. Murray71457APE No.Russell 76238 Ply:1 SEQN:17496/T67/COMN Custom-Roick Res. Qty: 2 FROM: DRW: 102 4/ Wgt:86.8 lbs ... / ... 07/19/2018 I 26°9 I 7'10" I 10'118 I 16.9" 2'5"9 5'4"7 3'1"8 566 C 14X5(") _ I 11:\ 13X4 i� 12 D�5x7("") E"") T,o.2s r tV -1- .4X4(B1)B 'Aldigi, % F (1)20'11' G =3X4 114X8(") A 1 T 18'11"14 1 169" 1 26'9 I 5,7,15 878 I 2's"9 8'1"8 169" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA ,VERT(LL): 0.218 G 911 240 A 732 /200 /406 /- /232 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.722 G 422 18jyF 714 /248 /408 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.198 F - - Wind reactions based on MWFRS Des Ld: 40.00 J EXP:D HORZ(TL): 0.427 F - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.76 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.629 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.973 Spacing:24.0"J MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.899 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 70 -464 C-D 486 -945 Wind Duration: 1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 332 -817 D-E 14 -36 Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2:T1 2x6 SP SS Dense: member design. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 Right end vertical not exposed to wind pressure. B-G 682 -314 G-F 1184 -620 Webs 2x4 SP#3 Lumber value set"13B"uses design values Additional Notes Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. 7-1-7. Plating Notes C-G 568 -171 D-F 650 -1229 (**)4 plate(s)require special positioning.Refer to G-D 384 -598 E-F 159 -200 scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.46 14.29 BC 110 0.02 14.29 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: 111- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (1111'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 A*1\ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX 1ueHouse PE No.60839 PE No 58544 PE No.71457 PE No.77693 76238 Ply: 1 SEQN: 17497/T66/COMN • Custom-Roick Res. Qty: 2 FROM: DRW: T03 At Wgt:93.8 lbs / ... 07/19/2018 I 2'5"9 I 7'10" 9'2"7( 169" 2'5"9 5'4"7 1.4"7 T6"9 C/5X5(") _ lt1� T2 3X4(•') D�SXS(") 0 E o N12 10.257 e e = m4X4(B1)B rd.MIIIIIIIMIIIMINEMIIIMEMENNI: 1 20'11. G F _m3X4 113X8(") A 1 I . 18'11'14 1 169" i 2'5"9 57"15 87"8 II 2'59 ) 8'1"8 ( 16'9" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA JVERT(LL): 0.213 G 931 240 A 732 /183 /421 /- /231 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.706 G 431 180,F 714 /301 /413 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.192 F - -Wind reactions based on MWFRS Des Ld: 40.000/ EXP:D HORZ(TL): 0.414 F - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.76 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.820 Bearing A Fcperp=565psi. Load Duration:11,5 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.789 Spacing:24.0"44/ MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.383 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 22 -464 C-D 452 -821 Wind Duration:1.60 WAVE VIEW Ver: 18.01.00B.0430.21 B-C 314 -825 D-E 16 -32 Lumber Loading Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x6 SP SS Dense:T2 2x4 SP#2: live load. Chords Tens.Comp. Chords Tens. Comp. :T3 2x4 SP#1: Truss designed for unbalanced load using 0.00/1.00 B-G 693 -396 G-F 799 -446 Bot chord 2x4 SP#2 windward/leeward factors. Webs 2x4 SP#3 Wind Maximum Web Forces Per Ply(lbs) Lumber value set"13B"uses design values Webs Tens.Comp. Webs Tens. Comp. approved 1/30/2013 by ALSC Wind loads based on MWFRS with additional C&C member design. C-G 486 -121 D-F 480 -855 Bracing Right end vertical not exposed to wind pressure. G D 187 -318 E-F 202 261 (a)Continuous lateral restraint equally spaced on member. Additional Notes Plating Notes The overall height of this truss excluding overhang is 7-1-7. ("")4 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.46 14.29 BC 120 0.02 14.29 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer RW\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX TrueHouse PE No 60839 PE No 58544 PE No.71457 PE No.77693 76238 Ply:1 SEQN: 17498/T69/COMN Custo -Roick Res. Qty: 2 FROM: DRW: TO Ar Wgt:93.8 lbs ... / ... 07/19/2018 I 25'9 I 731 I 12 I 169' I 2'5'9 4'9'8 4'9' 4'9' •5X5(-) x 3X4 113X4(") C D el E 1iI, 12 `O . Aldl All6111L m 10.25 e P I` =4x4(81)B T G iF 20'11" S •3X4 113X8(") A 1_ 1 T 1 - - m16'1114 A 169" 1 �J I 259 -I 51 927 _I 25"9 7'6"9 16'9" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NAVERT(LL): 0.199 G 998 240 A 732 /181 /429 /- /256 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA V VERT(TL): 0.659 G 462 18(x,F 714 /335 /402 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.177 F - !I/ Wind reactions based on MWFRS Des Ld: 40.00 J EXP:D HORZ(TL): 0.381 F - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.51 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.538 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.534 Spacing:24.01"/ MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.592 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 13 -464 C-D 440 -730 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 319 -859 D-E 0 0 Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x6 SP SS Dense:T2 2x4 SP#2: member design. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP SS Right end vertical not exposed to wind pressure. B-G 730 -450 G-F 552 -350 Webs 2x4 SP#3 Lumber value set"13B"uses design values Additional Notes Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. 6-7-8. Plating Notes C-G 161 -60 D-F 477 -753 (")3 plate(s)require special positioning.Refer to G-D 321 -124 E-F 105 -126 scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.46 14.29 BC 120 0.02 14.29 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: N- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (IIT'll) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Flonda Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ T�rueHouse PE No l 0839z1owski PEffrNo 58544 ey P Arneson PE No.1457y Adam K PE No.7769311 APEX 76238 Ply:1 SEAN:17499/T62/COMN ' Custom-Roick Res. Qty: 2 FROM: DRW: T05 J Wgt:92.4 lbs ... / ... 07/19/2018 I� 259 1 710 I 1021 ` 169" 2'S"9 5'4"7 2'4"1 66"15 C 14X5("") T 13X4(") \D5X5l..l ET N 12 iN 1025 m n eV P- i4X4(B1)B 41111 :I. & IINIMMISEMINNIEN:. :II' G F m3X4 113X8(") A 1 - _ 11.14 1 16'9" 1 I 25„9 I S715 1 8'7 8 2'5"9 8'1"8 16'9" Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA j VERT(LL): 0.216 G 918 240 732 /193 /412 /- /229 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.716 G 425 180J 714 /273 /411 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.195 F - - Wind reactions based on MWFRS Des Ld: 40.004/ EXP:D HORZ(TL): 0.421 F - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.76 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.826 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.994 Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.309 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 -464 C-D 488 -909 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 323 -818 D-E 16 -34 Lumber Loading Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2:T1 2x6 SP SS Dense: live load. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 Truss designed for unbalanced load using 0.00/1.00 B-G 684 -350 G-F 971 -520 Webs 2x4 SP#3 windward/leeward factors. Lumber value set"13B”uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Wind loads based on MWFRS with additional C&C Bracing member design. C-G 555 -173 D-F 551 -1023 (a)Continuous lateral restraint equally spaced on Right end vertical not exposed to wind pressure. G-D 292 -443 E-F 178 -228 member. Additional Notes Plating Notes The overall height of this truss excluding overhang is (")4 plate(s)require special positioning.Refer to 7-1-7. scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.46 14.29 BC 120 0.02 14.29 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 6111r) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Jf*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX TrueHouse PE No 60839 PE No 58544 PE Na 71457 PE No.77693 76238 Ply: 1 SEQN:17505/T63/COMN Custom-Roick Res. Qty: 2 FROM: DRW: T06 J Wgt:85.4 lbs ... / ... 07/19/2018 2'5"9 710" 11'11"2 1619" 1- 2,5„9 I 54,7 I 4'1"2 I 4'9"14 I C 14X5(") - I12 113X4(") 10.25 ND\4X8(") E n .,. T _4x4(81)B � ti i F (S1 511115. It3X8(") A 1 i 8'11"14 1 169 1 I 25"9 I 5'7"15 I 87"8 2'5"9 8'1"8 16'9" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSE); DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NAVERT(LL): 0.222 G 895 240 A 732 /143 /399 /- /235 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA J VERT(TL): 0.735 G 415 180,�FF 714 /216 /404 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.204 F - -A/Wind reactions based on MWFRS Des Ld: 40.004✓ EXP:D HORZ(TL): 0.441 F - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.76 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.538 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.975 Spacing:24.0"J MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.821 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 103 -464 C-D 468 -978 Wind Duration:1.60 WAVE VIEW Ver: 18.01.008.0430.21 B-C 333 -817 D-E 12 -51 Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2:T1 2x6 SP SS Dense: member design. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 B-G 684 -271 G-F 1689 -867 Webs 2x4 SP#3 Additional Notes Lumber value set"13B"uses design values The overall height of this truss excluding overhang is MaximumWeb Forces Per approved 1/30/2013 by ALSC 7-1-7. Ply(lbs) ) Webs Tens.Comp. Webs Tens. Comp. Plating Notes C-G 568 -149 D-F 889 -1712 (")4 plate(s)require special positioning.Refer to G-D 625 -1038 E-F 134 -166 scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.46 14.29 BC 108 0.02 14.29 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer fiti\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PEi No.l 0 391owski Jeffreyo PSBASm44eson Pb No Murrayek B 1457PE No.Ru7ssell APEX 76238 Ply:1 SEQN:17541/T71/COMN Custom-Roick Res. Qty: 6 FROM: DRW: T07✓ Wgt:141.4 lbs ... / ... 07/19/2018 I 2'6"3 I 7'10" I 9'11"8 I 13'5"12 I 18'6" I 21'5" I 2'6"3 5'3"13 2'1"8 374 574 211" 5X7(••) .L - ,AD5x5ll 12 a4 T 12 N 7 'r' 10.25 F/3X4 rn =4X5(82)8 FSXS(") 1 L. v H..6X8(") _,),2i 291'8 1 i _ - 18'11'14 1 21'5" i 273 778 8'6"41 I 2,6„3 I 9,9„12 I 18,6.. I 1 ," h Loading Criteria(pst) Wind Criteria Snow Criteria(Pg, • PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CA • PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA 1VERT(LL): 0.307 H 1812 240 p 900 /192 /458 /- /227 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.976 H 389 19 888 /222 /412 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HUHL(LL): u.'L/tt r1 - - Wind reactions based on MWFRS Des Ld: 40.001f EXP:D HORZ(TL): 0.580 H - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.76 ft Code/Misc Criteria Creep Factor:2.0 G Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.698 Bearings A&G Fcperp=565psi. Load Duration: 1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.977 Spacing:24.0 MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.498 Maximum Top Chord Forces Per Ply(lbs) J C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 253 -573 D-E 726 -1614 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 491 -1119 E-F 1150 -2433 Lumber Loading C-D 910 -1815 F-G 148 -271 Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent Top chord 2x6 SP SS Dense:T2 2x4 SP#2: live load. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#1 Truss designed for unbalanced load using 0.00/1.00 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 windward/leeward factors. B-H 955 -259 H-F 2399 -1059 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Additional Notes Maximum Web Forces Per Ply(lbs) The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. Plating Notes 7-1-7. (")4 plate(s)require special positioning.Refer to C H 1306 -621 H-E 602 -1013 scaled plate plot details for special positioning H-D 410 -663 requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Tray Scab(s) (2)2x6x9-9-15 x SP SS Dense scabs at right end. Attach one scab to each outer face of chord with: 0.131"x3",min.nails @ 8"oc,plus additional nail clusters at:BRG.:(2),heel:(3),1st panel point:(2). Purlins In lieu of structural panels or rigid ceiling use puffins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.52 18.90 BC 106 -0.03 15.76 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 11- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11r11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fiV\ APEX TrueHouse MpEichNaoel6G08K3o9zIowskiJeffrey Ny No.58544 PEPE No.714579 APE No.7769311 76238 Ply:1 SEQN: 17507/T73/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T08 41 Wgt: 158.9 lbs ... / ... 07/19/2018 z� 10 3'1 11� 661 i 1'4"1 I 7'10" 1 9'11"8 1 13'5"12 1 18'6" 1 21'5" 1 1'6"1 I41113 2'1"8 3'6"4 5'0"4 2'11" 0 14X4(R) 12 10.25 V N,E445x7(-) 12 Q 4 F/3X4 13X4('•)a•4X5/5X7(•' . A B C T4 ii 1 I • 20'11" 5X5 K J I " T 4X5(") 6X8(") =5X7(-) T 1 20'1'8 A 21'5" j 74"8 Z1"8 6.61 1 I 7,10" I 9'11"8 I 18.6" I ��,' (� n Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA Jr VERT(LL): 0.207 F 999 240 L 868 /193 /456 /- /200 /- BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.644 F 592 201H 896 /227 /418 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.044 D - - Wind reactions based on MWFRS Des Ld: 40.0041 EXP:D HORZ(TL): 0.091 D - - L Min Brg Width Req= - NCBCLL: 10.00 Mean Height:23.29 ft Code/Misc Criteria Creep Factor:2.0 H Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.481 Bearing H Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.981 Spacing:24.0", MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.528 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 23 -41 E-F 799 -1669 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 1424 -2877 F-G 1206 -2441 Lumber Hangers/Ties C-D 632 -1313 G-H 150 -273 Value Set: 13B(Effective 6/1/2013) (J)Hanger Support Required,by others D-E 665 -1230 Top chord 2x4 SP#2:T4 2x6 SP SS Dense: LoadingMaximum Bot Chord Forces Per Plylbs Bot chord 2x4 SP#1 (lbs) Webs 2x4 SP#3:W1 2x6 SP#2: Bottom chord checked for 10.00 psf non-concurrent Chords Tens.Comp. Chords Tens. Comp. Lumber value set"13B"uses design values live load. L-K 1693 -740 J-I 1543 -586 approved 1/30/2013 by ALSC Truss designed for unbalanced load using 0.00/1.00 K-J 3229 -1565 I-G 2407 -1114 windward/leeward factors. Bracing Maximum Web Forces Per Ply(lbs) (a)Continuous lateral restraint equally spaced on Wind Webs Tens.Comp. Webs Tens. Comp. member. Wind loads based on MWFRS with additional C&C member design. A-L 62 -88 D-J 1254 -627 Plating Notes L-B 862 -1795 J-E 525 -1054 (")7 plate(s)require special positioning.Refer to Camber B-K 1387 -711 E-I 516 160 scaled plate plot details for special positioning Max JT VERT DEFL:LL:0.20"DL:0.42".See detail K-C 512 -828 I-F 589 -963 requirements. DEFLCAMB1014 for camber recommendations. C-J 1291 -2311 Plate positions consider a 0.50 inch truss perimeter Provide for adequate drainage of roof. edge distance. Additional Notes Tray Scab(s) The overall height of this truss excluding overhang is (2)2x6x9-9-15 x SP SS Dense scabs at right end. 5-2-5. Attach one scab to each outer face of chord with: 0.131"x3",min.nails @ 8"oc,plus additional nail clusters at:BRG.:(2),heel:(3),1st panel point:(2). Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 21.42 BC 91 0.00 18.27 Apply puriins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'1.1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Ronda Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ APEX TrueHouse PE No.l 083910 k1 Jeffrey No 58544 on FEPE No.71457y APE No.Russell 69311 76238 Ply:1 SEQN:17536/T70/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T091 Wgt:156.8 lbs ... / ... 07/19/2018 47"4 7'10" 911"8 13'5"12 18'6" 21'5" 47"4 I' 3'2"12 I 2'1"8 I 3'6"4 I 50"4 I 2,11" I- 12 C lll4X4(A) 0.25 VOIN o�5X7( ) 12 113X4( ) ,, a 4 T .- 0 -fsf A 15X7(")B 0 ••►•L F/3X4 m 9) Ell m n m T4 w • F=5X5(") J I H • IN4X8(") =4X8 =5X7(") B2 -'5 j_ j_ 0 20'1'8 1 21'5' i 7,10„ I 2.1"8 I 8'6„8I I '11. 1 710" 9'11"B 18'6" i Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pt in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA JVERT(LL): 0.178 E 999 240 J 870 /243 /463 /- /195 /- BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.555 E 688 201,G 895 /226 /422 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.058 C - �/ Wind reactions based on MWFRS Des Ld: 40.00 Al EXP:D HORZ(TL): 0.119 C - - J Min Brg Width Req= - NCBCLL: 10.00 Mean Height:23.29 ft Code/Misc Criteria Creep Factor:2.0 G Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.357 Bearing G Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.993 Spacing:24.04 MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.774 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 7 -26 D-E 811 -1666 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 B-C 632 -1258 E-F 1212 -2431 Lumber Loading C-D 662 -1236 F-G 150 -273 Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent Top chord 2x4 SP#2:T4 2x6 SP SS Dense: live load. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2:B2 2x4 SP#1: Truss designed for unbalanced load using 0.00/1.00 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 windward/leeward factors. J-I 1444 -603 H-F 2397 -1120 Lumber value set"13B"uses design values I-H 1542 -599 approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Ply(lbs) Plating Notes member design. Webs Tens.Comp. Webs Tens. Comp. (")6 plate(s)require special positioning.Refer to Left end vertical not exposed to wind pressure. scaled plate plot details for special positioning A-J 127 -146 I-D 588 -1086 requirements. Camber J-B 819 -1564 D-H 481 -188 Plate positions consider a 0.50 inch truss perimeter Max JT VERT DEFL:LL:0.15"DL:0.35".See detail B-I 409 -630 H-E 581 -952 edge distance. DEFLCAMB1014 for camber recommendations. C-I 1338 -676 Provide for adequate drainage of roof. Tray Scab(s) (2)2x6x9-9-15 x SP SS Dense scabs at right end. Additional Notes Attach one scab to each outer face of chord with: The overall height of this truss excluding overhang is 0.131"x3",min.nails @ 8"oc,plus additional nail 5-2-5. clusters at:BRG.:(2),heel:(3),1st panel point:(2). Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 21.42 BC 107 0.00 18.27 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (ilivii) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,f*/\ APEX TrueHouse PE No.Michael 08391owski Jeffrey No 58544 on PEPE No 71457y APE No Russell • 76238 Ply:1 SEQN:17509/T60/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T10 ✓ Wgt:157.5 lbs ... / ... 07/19/2018 33'2 7'10" 9'11"8 13'5.'12 18'6" 21'5" I' 3'3°2 I 4'6"14 I 2'1°8 I 3'6°4 I 5'0„4 I 2,11„ "I - C III4X4(R) 12 10.25 V D\5X7(") 1- 12 Q 4 T N N (� Ln /111111118411%.•,,...,......:63X4mAl 3X4 04X10(")B •�• •T4 m ml ill • :.F.SX.(.) • 1 AN20',1. J 57*. I H B2 • G T =5X7 =5X7(..) 75 1201'8 A 21'5" j I 710" I 2'1"8 I 8,6„8 1," , Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA ./VERT(LL): 0.196 E 999 240 J 876 /192 /463 /- /199 /- BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA w VERT(TL): 0.614 E 623 20' t G 896 /227 /418 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.051 C - - Wind reactions based on MWFRS Des Ld: 40.04 EXP:D HORZ(TL): 0.106 C - - J Min Brg Width Req= - NCBCLL: 10.00 Mean Height:23.29 ft Code/Misc Criteria Creep Factor:2.0 G Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.366 Bearing G Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.976 Spacing:24.Q, MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.689 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 3 -132 D-E 806 -1669 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 622 -1296 E-F 1211 -2439 Lumber Loading C-D 654 -1228 F-G 150 -273 Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent Maximum Bot Chord Forces Per Ply chord 2x4 SP#2:T4 2x6 SP SS Dense: live load. (lbs ) Bot chord 2x4 SP#2:B2 2x4 SP#1: Truss designed for unbalanced load using 0.00/1.00 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3:W1 2x6 SP#2: windward/leeward factors. J-I 2404 -1200 H-F 2404 -1119 Lumber value set"13B"uses design values I-H 1544 -593 approved 1/30/2013 by ALSC Wind Wind loads based on MWFRS with additional C&C Maximum Web Forces Per Ply(lbs) Plating Notes member design. Webs Tens.Comp. Webs Tens. Comp. (")5 plate(s)require special positioning.Refer to Camber scaled plate plot details for special positioning A-J 80 -110 I-D 565 -1075 requirements. Max JT VERT DEFL:LL:0.18"DL:0.38".See detail J-B 1348 -2414 D-H 497 -192 Plate positions consider a 0.50 inch truss perimeter DEFLCAMB1014 for camber recommendations. B-I 953 -1512 H-E 586 -959 edge distance. Provide for adequate drainage of roof. C-I 1277 -631 Tray Scab(s) Additional Notes (2)2x6x9-9-15 x SP SS Dense scabs at right end. The overall height of this truss excluding overhang is Attach one scab to each outer face of chord with: 5-2-5. 0.131"x3",min.nails @ 8"oc,plus additional nail clusters at:BRG.:(2),heel:(3),1st panel point:(2). Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 21.42 BC 98 0.00 18.27 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. ( r11l) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ift/\ Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX TrueHouse PE No.60839 PE No 58544 PE No.71457 PE No.77693 76238 Ply:1 SEQN:17552/T72/COMN Custom-Roick Res. Qty: 2 FROM: DRW: T11 J Wgt:84.0 lbs / ... 07/19/2018 3'1"1264" 9'6"4 178" vl 3'1"12 I 3'2"4 I 3'2"4 I 3'1"12 D 14X5(--) -1 _ < 12 ok3X8C E\3X8 =4X41C3 Ihl& m4X4(C3) of4X4(C3)6- I �-� , 2:,74.(c3) 020'll' 1 . II O \ I H G A 13X8 .5X7 13X8 12'8" 3' 3'4" 34" 3' 2' I 3' -I 6,4.E I 9,8,E I 128" I Loading Criteria(pst) Wind Criteria Snow Criteria(Pg,Pt in PSF) DefVCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA ♦ VERT(LL): 0.046 H 999 240 B 2747 /1098 - /- /- /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA 4/ VERT(TL): 0.140 H 999 180 F 2256 /866 - /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.017 C - - Wind reactions based on MWFRS Des Ld: 40.00/ EXP:D HORZ(TL): 0.034 C - - B Min Brg Width Req= 3.2 NCBCLL: 10.00 Mean Height:22.95 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= 2.7 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.647 Bearings B&F Fcperp=565psi. Load Duration: 1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.982 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.916 Maximum Top Chord Forces Per Ply(lbs) J C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 84 -56 D-E 881 -2146 Wind Duration: 1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 1212 -3143 E-F 1226 -3105 Lumber Loading C-D 880 -2147 Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent live load. Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x6 SP#2 Wind Webs 2x4 SP#3 B-I 2485 -941 H-G 2430 -955 Lumber value set"13B"uses design values Wind loads and reactions based on MWFRS. I-H 2459 -933 G-F 2456 -963 approved 1/30/2013 by ALSC Additional Notes Special Loads The overall height of this truss excluding overhang is Maximum Web Forces Per Ply(lbs) (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) 5-1-14. Webs Tens.Comp. Webs Tens. Comp. TC:From 65 plf at -2.00 to 65 plf at 0.88 Top Chord overhang(s)may be field trimmed. I-C 1047 -320 H-E 322 -888 TC:From 33 plf at 0.88 to 33 plf at 12.67 C-H 296 -923 E-G 1017 -336 BC:From 5 plf at -2.00 to 5 plf at 0.00 D-H 2403 -939 BC:From 10 plf at 0.00 to 10 plf at 12.67 BC: 714 lb Conc.Load at 0.88,2.88,4.88,6.88 8.88,10.88 Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 12.67 BC 85 0.15 12.52 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: I" 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if"\ APEX TrueHouse PE No l 0 391owskirey P No 58544 Arneson PEPE No.71457y PE No.Russell 69311 • 76238 Ply:1 SEQN:17546/T61/COMN • Custom-Roick Res. Qty: 4 FROM: DRW: T12 J Wgt:57.4 lbs / ... 07/19/2018 F 6,4,. { 128" I 6,4,. 64" �i4x4(••) _ 12 m i0 io m3X4(81T)B Dm3X4(81) _ I FA e. _2011' E A 13X4 1 12'8" 1 F-2' I 64 I 6'4" I 6'4" 12'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSE) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):-0.007 E 999 240 B 691 /322 /476 /- /236 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA J VERT(TL): 0.018 E 999 180 D 538 /229 /322 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.011 E - V Wind reactions based on MWFRS Des Ld: 40.00 Af EXP:D HORZ(TL): 0.012 E - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.95 ft Code/Misc Criteria Creep Factor:2.0 D Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.498 Bearings B&D Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.959 Spacing:24.04 MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.108 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 84 0 C-D 284 -613 Wind Duration:1.60 WAVE I VIEW Ver:18.01.0OB.0430.21 B-C 293 -613 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 5-1-14. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. B-E 406 -79 E-D 406 -79 Webs 2x4 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Plating Notes C-E 282 0 (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 12.67 BC 120 0.15 12.52 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: NI' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (115'1.1 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ APEX TrueHouse PE No.Michael 08391owski Jeffrey 58544 on PE PE No MurrayDerek B1457APE No.Russell 76238 Ply:1 SEAN: 17549/T68/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T13✓ Wgt:32.2 lbs ... / ... 07/19/2018 I 3' I 6' I a 3' C 1114X4(R) T9A! 4X4AlT) co 1 20'11" A 1113X8 E r 6' i I--1' I3, -I- 6, I 1'--I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA .VERT(LL): 0.010 F 999 240 B 1745 /422 /- /- /- /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.032 F 999 180 D 1535 /421 /- /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.004 F - 4 Wind reactions based on MWFRS Des Ld: 40.00/ EXP:D HORZ(TL): 0.007 F - - B Min Brg Width Req= 2.1 NCBCLL: 10.00 Mean Height:22.07 ft Code/Misc Criteria Creep Factor:2.0 D Min Brg Width Req= 1.8 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.238 Bearings B&D Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.677 Spacing:24.0"J MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.545 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 -14 C-D 359 -1419 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 348 -1417 D-E 42 -27 Lumber Loading Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 live load. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x6 SP#2 B-F 1113 -268 F-D 1113 -268 Webs 2x4 SP#3 Additional Notes Lumber value set"13B"uses design values The overall height of this truss excluding overhang is Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC 2-7-14. Top Chord overhang(s)may be field trimmed. Webs Tens.Comp. Special Loads C-F 1433 -332 (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC:From 33 plf at -1.00 to 32 plf at 4.76 TC:From 65 plf at 4.76 to 65 plf at 7.00 BC:From 5 plf at -1.00 to 5 plf at 0.00 BC:From 10 plf at 0.00 to 10 plf at 6.00 BC:From 5 plf at 6.00 to 5 plf at 7.00 BC: 868 lb Conc.Load at 0.76 BC: 870 lb Conc.Load at 2.76 BC: 876 lb Conc.Load at 4.76 Plating Notes Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.00 7.00 BC 68 0.15 5.85 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. NOTES: I.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, (rlg- should be used in conjunction with the architectural plans during installation. TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,"\ APEX TrueHouse PE No.l 60839 1owski PErNo 58544 Arneson PE No.71457y APE No.7769311 76238 Ply:1 SEQN:17547/T56/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T14 ✓ Wgt:25.2 lbs ... / ... 07/19/2018 I- 3 I- 6' H 3' 3' C= 3X4(,.) T T /_N NV1 - T) co L ()20'11" AE r 6' i I'-1' I- 6' I 1'---I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Lldefl U# LocR /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.001 999 240 B 333 /97 /232 /- /132 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA 4/VERT(TL): 0.008 999 180DI 333 /97 /232 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.001 - - _Wind reactions based on MWFRS Des Ld: 40.00 4/ EXP:D , HORZ(TL): 0.005 - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.07 ft Code/Misc Criteria Creep Factor:2.0 D Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.117 Bearings B&D Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.252 Spacing:24.0:1 MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.000 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 0 C-D 132 -226 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 132 -226 D-E 42 0 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 2-7-14. Chords Tens.Comp. Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. B-D 148 -69 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.00 7.00 BC 68 0.15 5.85 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (Ir'H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,f*/\ APEX TrueHouse MPE No l Q 3a9zlowskirey P No S8544son PEPE No.71457y PE No.Russell 69311 • ' 76238 Ply:1 SEQN:17554/T20/ATIC Custom-Roick Res. Qty: 5 FROM: DRW: T15 J Wgt:280.0 lbs Page 1 of 2 ... / ... 07/19/2018 ' 23'1"1~313 1 I 8'0'7 I 39'910 I 1336444 I11.521' F013 I22574" I 4305"9 I 36'6' 8'0'7 1907 /5X5('") ...505r) E F G H I DA' L•.i�\ate\ate\II A Y X 15'9" 2 T 10.25 �I5%5(.. e . \5x5( ) ,14 ia -++ li X m ,:Z AB V9 AD5 AF �4%4(Bt)A id I ` I _I,�I I c4 .4X41B1I _ � X10'1.2 V U T SCD • • D P 0 N =4X5 .5X5("') -�10 m555(") •4X4 1 16'4"4 1 18'1'12 '1 I e'0"12 3;72 2'10'15 2'10'2 11 7"1} 2'3'8 4'8'12 6'0'12 fi'0"12 I 9'B"B I 12'7'7 I 15'5'9 11 3 18'4"�1,5- 0'9/2 2'7 4 I 25'8'8 I 30'5'4 I 36'6" I 1'6'8'3 19'9' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL): 0.179 D 999 240 A 1075 /245 /466 /- /289 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.641 U 562 180 R 1463 /193 /401 /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.133 C - 4/ M 1026 /243 /439 /- /- /6.5 Des Ld: 40.004/ EXP:D HORZ(TL): 0.302 C - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:18.31 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.875 R Min Brg Width Req= 1.5 ' - -'n'''''""^'1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.970 M Min Brg Width Req= 1.5 Spacing:16.0' It MWFRS Parallel Dist:0 to h/2 Rep Factors Used:YesI Max Web CSI: 0.570 Bearings A,R,&M Fcperp=565psi. C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 Lumber Loading A-B 405 -1443 G-H 445 -789 Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent C-D 379 -1018 H- 168 -228 live load. C-D 379 -852 I-J 174 -301301 Top chord 2x4 SP#2:T3 2x4 SP#1: D-E 167 -253 J-K 384 -804 Bot chord 2x4 SP#2:B2 2x4 SP#1: Attic room loading from 9-10-0 to 25-7-0:Live Load: E-F 157 -154 K-L 357 -1011 Webs 2x4 SP#3 4/ 40 PSF.Dead Load:10 PSF Ceiling:10 PSF, F-G 451 -778 L-M 410 -1375 Lumber value set"13B"uses design values Kneewalls: 10 PSF approved 1/30/2013 by ALSC Truss designed for unbalanced load using 0.00/1.00 Maximum Bot Chord Forces Per Ply(lbs) windward/leeward factors. Chords Tens.Comp. Chords Tens. Comp. Bracing (a)Continuous lateral restraint equally spaced on Wind A-V 1034 -278 R-Q 949 -121 member. Wind loads based on MWFRS with additional C&C V-U 2441 -758 Q-P 992 -129 member design. U-T 2472 -768 P-O 2047 -543 Plating Notes T-S 1364 -368 O-N 2021 -534 All plates are 3X4 except as noted. Additional Notes S-R 1324 -362 N-M 984 -215 (")6 plate(s)require special positioning.Refer to The overall height of this truss excluding overhang is scaled plate plot details for special positioning 11-10-0. Maximum Web Forces Per Ply(lbs) requirements. Webs Tens.Comp. Webs Tens. Comp. Plate positions consider a 0.50 inch truss perimeter B-V 526 -143 GAC 117 -180 edge distance. B-W 309 -618 R-AD 420 -1849 Purlins V-W 502 -1539 AB-R 125 -90 In lieu of structural panels or rigid ceiling use purlins C W 178 79 AB-AD 1466 281 to laterally brace chords as follows: W U 251 17 AC H 267 108 Chord Spacing(in oc) Start(ft) End(ft) W-T 552 -1182 AC-AE 76 -343 TC 24 0.00 36.50 W-X 283 -845 AD-Q 405 -101 BC 83 0.15 36.35 T-X 191 -108 AD-AF 440 -491 Apply purlins to any chords above or below fillers X-Z 294 -811 H-AE 296 -496 at 24"OC unless shown otherwise above. D-Y 347 -787 AE-I 376 -190 Collar-tie braced with continuous lateral bracing at E-Y 390 -185 AE-J 359 -797 24"oc.or rigid ceiling. Y-F 292 -511 AF-P 218 -116 Y-AA 40 -302 AF-AG 434 -528 F-AA 278 -104 P-AG 474 -1161 S-Z 384 -93 AG-O 272 -16 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ TrueHouse PE No.Michael 08391owskiJeffrey No 58544 on PEPE No. MurrayDerek B1457APE No.7Russell APEX 76238 Ply:1 SEQN: 17554/T20/ATIC Custom-Roick Res. Qty: 5 FROM: DRW: T15 Wgt:280.0 lbs Page 2 of 2 / ... 07/19/2018 Z-R 447 -2061 AG-K 221 -110 Z-AB 1466 -281 AG-N 581 -1173 AA-G 113 -192 AG-L 272 -494 AA-AC 258 -300 N-L 356 -134 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer g /\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse PE No.Michael 6083910i Jeffrey No 58544 on PEPE No. MurrayDerek B1457APE No.dam K Russell APEX 76238 Ply:1 SEAN:17556/T13/ATIC Custom-Roick Res. Qty: 5 FROM: DRW: T16 At Wgt:280.0 lbs Page 1 of 2 ... / ... 07/19/2018 I.18'" 23.1•'1 3 I 8.0.7 610' 13'4'4 15'2' 21313 19.1 25'7" 30'5'9 36'6' I 6.0.7 I 3'9"9 I 3'6'4 11.8.1 I 3'0'13'f I 2.5..4 I 4'10.9 l 60 7 I /5X5(••) a5X5(••) E F G H I it;7.0.!.........40:110.-.-" \j A .. v AA , � 159' -\; z T ozs /sxs( B . .. 5x5(..) \ • - 0 4x5 X ,;Z Ae AD AF .4X4(611A .�''`i_' !,,!-__!�. M 4X4(81) 1 . _ - - - - 10'1'2 V U 7 s ID 0 P 0 N 405 •5X5(") �'1r0 m5X5(••) im4X4 Ar j 1134"4 j 18'1.12 j 6'0"12 37'19'3"8 2'27 7 2.15'2 1'7'1} 2'3'8 30'5 4 366' I 8'0'12 I 9'B"B I 12'7'7 I 15'5'9 1 1313 1194a 1'S" 0'9 2 2,74 I 2s'8'BI 30'5'4 I 36'6" I 17109 19.9' F.--=.1' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NAVERT(LL): 0.179 D 999 240 A 1075 /244 /466 /- /289 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA JVERT(TL): 0.641 U 562 180 R 1463 /193 /401 /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.133 C - 4/ M 1026 /242 /438 /- /- /- Des Ld: 40.00 4/ EXP:D HORZ(TL): 0.302 C - - Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height:18.31 ft Code/Misc Criteria Creep Factor:2.0 A Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.875 R Min Brg Width Req= 1.5 BCDL:3.0psf TPI Std: 2014 Max BC CSI: 0.971 M Min Brg Width Req= - �oao vurauon. .25Bearings A&R Fcperp=565psi. Spacing:16.0" 4/ MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.570 C&C Dist a:3.65 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs) GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 Lumber Hangers/Ties A B 405 -1444 G H 446 788 C Value Set:13B(Effective 6/1/2013) (J)Hanger Support Required,by others C-D 379 -1019 H-1 168 -228 C-D 379 -852 I-J 174 -301 Top chord 2x4 SP#2:T3 2x4 SP#1: Loading D-E 167 -253 J-K 384 -805 oan Bot chord 2x4 SP#2:82 2x4 SP#1: g E-F 157 -153 K-L 357 -1012 Webs 2x4 SP#3 Bottom chord checked for 10.00 psf non-concurrent F-G 451 -777 L-M 411 -1380 Lumber value set"13B"uses design values live load. approved 1/30/2013 by ALSC Attic room loading from 9-10-0 to 25-7-0:Live Load: Maximum Bot Chord Forces Per Ply(lbs) If 40 PSF.Dead Load:10 PSF Ceiling:10 PSF, Chords Tens.Comp. Chords Tens. Comp. Bracing Kneewalls: 10 PSF (a)Continuous lateral restraint equally spaced on Truss designed for unbalanced load using 0.00/1.00 A-V 1035 -278 R-Q 952 -120 member. windward/leeward factors. V-U 2441 -758 Q-P 995 -128 U-T 2471 -768 P-0 2052 -543 Plating Notes Wind T-S 1365 -368 O-N 2025 -534 All plates are 3X4 except as noted. Wind loads based on MWFRS with additional C&C S-R 1325 -363 N-M 988 -216 member design.(")6 plate(s)require special positioning.Refer to scaled plate plot details for special positioning Maximum Web Forces Per Ply(lbs) requirements. Additional Notes Webs Tens.Comp. Webs Tens. Comp. Plate positions consider a 0.50 inch truss perimeter The overall height of this truss excluding overhang is edge distance. 11-10-0. B-V 526 -143 G-AC 117 -180 B-W 309 -618 R-AD 421 -1851 Purlins V-W 502 -1538 AB-R 125 -90 In lieu of structural panels or rigid ceiling use purlins C W 179 79 AB-AD 1464 282 to laterally brace chords as follows: W U 251 17 AC-H 267 108 Chord Spacing(in oc) Start(ft) End(ft) W-T 552 -1181 AC-AE 75 -343 TC 24 0.00 36.50 W-X 284 -845 AD-Q 405 -102 BC 83 0.15 36.38 T-X 191 -108 AD-AF 438 -493 Apply purlins to any chords above or below fillers X-Z 294 -812 H-AE 296 -496 at 24"OC unless shown otherwise above. D-Y 347 -789 AE-I 376 -190 Collar-tie braced with continuous lateral bracing at E-V 391 -185 AE-J 359 -798 24"oc.or rigid ceiling. Y-F 292 -511 AF-P 218 -116 Y-M 40 -303 AF-AG 432 -530 F-AA 278 -104 P-AG 475 -1162 S-Z 384 -93 AG-O 271 -16 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (gill) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 /f*/\ TrueHouse PE No81 08391owski Jeffrey No 58544 Arneson PEPE No. MurrayDerek 871457Adam K PE No.77693 Russell APEX 76238 Ply:1 SEQN:17556/T13/ATIC Custom-Roick Res. Qty: 5 FROM: DRW: T16 Wgt:280.0 lbs Page 2 of 2 ... / ... 07/19/2018 Z-R 447 -2060 AG-K 222 -110 Z-AB 1464 -282 AG-N 580 -1173 AA-G 113 -192 AG-L 273 -499 AA-AC 256 -300 N-L 359 -134 NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (1111'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 "V\ TrueHouse PE Michael G83 KozlowskiNo. Jeffrey 58544 on PE PE No. MurrayDerek B7457APE E No.dam K Russell 7APEX 76238 Ply:1 SEQN:17558/T1/ATIC • Custom-Roick Res. Qty: 14 FROM: DRW: T174/ Wgt:180.6 lbs , ... / ... 07/19/2018 37'15 6'10.4 12' 17'1'12 20'4'1 24' I 3'7'15 I 3'2'5 I 5'1'12 I 5'1'12 ' 3'2'5 I 3'7'15 I T F 14X8(R) - li T2 E3X'', 3X4 ry 2 B3 13x80 A 13X4 likh. H 1355 '8 12 10 'sr ' TN.4XSI.I 4X5('•)C `O 04' jn m4X4(CB3T) `OX4(C3T) =3X4(C3T)/ 'm 3X4(C3T) 1II A/ 64 L � i ii _46'8-10 ,, =8X8(")(I) .68X8(")(I) �K 24 i I-r6• I 66 I 54 I sa I 6'8' 11'6--{ 6'5' 12' 17'4' 24' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL): 0.153 M 999 240 B 1824 /349 /728 /- /392 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.557 M 803 227.,.1 1824 /349 /728 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.097 D - 4 Wind reactions based on MWFRS Des Ld: 40.004, EXP:D HORZ(TL): 0.224 D - - B Min Brg Width Req= 1.8 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 J Min Brg Width Req= 1.8 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.532 Bearings B&J Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.934 Spacing:24.0"J MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.509 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 63 0 F-G 120 -109 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 B-C 611 -2746 G-H 532 -1708 Lumber Loading C-D 578 -2525 H-I 578 -2525 Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent D-E 532 1708 I-J 610 2746 Top chord 2x4 SP#2:T2 2x6 SP SS Dense: live load. E-F 120 -108 J-K 63 0 Bot chord 2x6 SP SS Dense:B3 2x4 SP#2: Attic room loading from 7-0-0 to 17-0-0:Live Load:40 Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 SP#3 I PSF.Dead Load:10 PSF Ceiling:10 PSF,Kneewalls: Chords Tens.Comp. Chords Tens. Comp. Lumber value set"138"uses design values �/ 10 PSF approved 1/30/2013 by ALSC Truss designed for unbalanced load using 0.00/1.00 B-M 2149 -329 L-J 2149 -340 windward/leeward factors. M-L 1801 -150 Plating Notes (I)-plates so marked were sized using 0% Additional Notes Maximum Web Forces Per Ply(lbs) Fabrication Tolerance,0 degrees Rotational The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. Tolerance,and/or zero Positioning Tolerance. 9-4-14. (")4 plate(s)require special positioning.Refer to Top Chord overhang(s)may be field trimmed. C-M 254 -501 N-G 594 -1986 scaled plate plot details for special positioning M-D 1167 -101 H-L 1167 -101 requirements. E-N 594 -1986 L-I 254 -501 Plate positions consider a 0.50 inch truss perimeter F-N 319 -72 edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -1.50 25.50 BC 120 0.15 23.85 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Collar-tie braced with continuous lateral bracing at 24"oc.or rigid ceiling. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61'11'1-) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer fi*/\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No.Michael 0839lowski Jeffrey 58544 Arneson EPE No. Murray71457APE No.77693 7 Russell 76238 Ply:1 SEQN: 17564/T6/COMN Custom-Roick Res. Qty: 2 FROM: DRW: T184/ Wgt: 100.8 lbs ... / ... 07/19/2018 I 5'0'8 I 9'9' I 14'5'8 I 19'6' I 5'0'8 4'8'8 4'8'8 5'0'8 0im4X4 - %3X4 C E•3X4 2 P..' 79 AIIIIIIIIhh, m3x4(B 1 T)B r=3X4031 T) T ■■ _0101'2 H A =5X7(..) G - A 196 A 9'9' 9'9' I"_p• II I 19.6. I p• Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria •Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.024 H 999 240 B 977 /123 /651 /- /358 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA 1 VERT(TL): 0.074 H 999 184 F 977 /123 /650 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.011 H - tir Wind reactions based on MWFRS Des Ld: 40.00 EXP:D - HORZ(TL): 0.023 H - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.424 Bearings B&F Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.994 Spacing:24.0W MWFRS Parallel Dist:h to 2h Rep Factors Used:Yes Max Web CSI: 0.215 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 84 0 D-E 343 -808 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 B-C 363 -1063 E-F 364 -1063 Lumber Additional Notes C-D 342 -808 F-G 84 0 Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Top chord 2x4 SP#2 7-8-10. Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp. Chords Tens. Comp. Webs2x4SP#3 B-H 786 -259 H-F 786 -121 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Plating Notes Webs Tens.Comp. Webs Tens. Comp. (")1 plate(s)require special positioning.Refer to C-H 237 -292 H-E 236 -292 scaled plate plot details for special positioning D-H 565 -197 requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 21.50 BC 120 0.15 19.35 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11...11111 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc,Florida Corporation. Florida Engineer Jft\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse MPE Nola 3ogzlowski Jeffrey No 58544 Arneson PEPE No. Murray1457APE No.7769311 76238 Ply:2 SEQN:17751/T19/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T19 J Wgt:254.8 lbs ... / ... 07/19/2018 5'2'4I 9'9' I 14'3'12 I 19'6' 5'2'4 4'6'12 4'6'12 5'2'4 G 14X8(") T T Vg N 0.6X8(9 C E%6X8(") 12 9 • .6X6(" 411. 6X6(") .4%5(••)'I I Imo I I 4X5(..) 1 T IIE.-U.-U�\� _00.10'1'2 I H G A 14X10(") .10512(") 14X10(') 1 196 1 5'0'8 4'818 4'e'8 5'0'8 I-2' I 5'0.8 I 9'9. I 14'5'8 I 19'6' I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA 4/ VERT(LL): 0.097 H 999 24 B 4780 /1376 / /- /- /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.292 H 999 181 F 7147 /1766 / /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.033 C - J vvrna reaulluns uas on MWFRS Des Ld: 40.00-4 EXP:D HORZ(TL): 0.065 C - - B Min Brg Width Req= 2.5 NCBCLL:0.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= 3.7 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.886 Bearings B&F Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.712 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:No Max Web CSI: 0.809 Maximum Top Chord Forces Per Ply(lbs) J C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 42 -21 D-E 860 -3144 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 1033 -3686 E-F 1262 -4893 Lumber Plating Notes C-D 855 -3133 Value Set:13B(Effective 6/1/2013) (")10 plate(s)require special positioning.Refer to Top chord 2x4 SP#2 scaled plate plot details for special positioning Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x6 SP SS Dense requirements. Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3:W3 2x4 SP#2: Plate positions consider a 0.50 inch truss perimeter B-I 29(72 -803 H-G 3848 -984 :Lt Wedge 2x6 SP#2::Rt Wedge 2x6 SP#2: edge distance. I-H 2893 -801 G-F 3878 -991 Lumber value set"13B"uses design values purlins approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) In lieu of structural panels or rigid ceiling use purlins Webs Tens.Comp. Webs Tens. Comp. Nailnote to laterally brace chords as follows: Nail Schedule:0.131"x3",min.nails Chord Spacing(in oc) Start(ft) End(ft) I-C 549 -147 H-E 408 -1765 Top Chord:1 Row @12.00"o.c. TC 24 2.00 19.50 C-H 170 -530 E-G 2024 -421 Bot Chord:2 Rows @ 6.00"o.c.(Each Row) BC 120 0.15 19.35 D-H 45f12 -929 Webs 1 Row 4"o.c. Apply purlins to any chords above or below fillers Use equal spacing between rows and stagger nails at 24"OC unless shown otherwise above. in each row to avoid splitting. Wind 12"o.c.spacing of nails perpendicular and parallel to grain required in area over bearings greater than 12" Wind loads and reactions based on MWFRS. Special Loads Additional Notes (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) The overall height of this truss excluding overhang is TC:From 65 plf at -2.00 to 65 plf at 7.06 7-8-10. TC:From 33 plf at 7.06 to 33 plf at 9.75 Top Chord overhang(s)may be field trimmed. TC:From 65 plf at 9.75 to 65 plf at 19.50 BC:From 5 plf at -2.00 to 5 plf at 0.00 BC:From 20 plf at 0.00 to 20 plf at 7.06 BC:From 10 plf at 7.06 to 10 plf at 19.50 BC:2090 lb Conc.Load at 7.06 BC: 956 lb Conc.Load at 9.06 BC: 480 lb Conc.Load at 10.17 BC:1026 lb Conc.Load at 11.05,12.38,12.84,14.17 15.50 BC: 764 lb Conc.Load at 16.76 BC: 915 lb Conc.Load at 18.02 NOTES: 1r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (grvil) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if*/\ APEX TrueHouse PE No.160 39lowskiPEJeffrey No 58rneson PE No.71457y PE No.Russell • 76238 Ply:1 SEAN: 17562/T21/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T20 4♦ Wgt: 109.2 lbs ... / ... 07/19/2018 7'8"9 ( 13'0'4 ( 18'4' 7'8'9 5'3"12 5'3"12 /5X7(") =3X4 113X4(-") B C D i5 12 10.25 /4X5('")A ii i;., 0 1012 F CD E =5X7("") 13X8(—) A 184 A 8' ( 10'4" 8' 18'4" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA , VERT(LL): 0.014 F 999 240 A 936 /190 /515 /- /280 /4.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.046 F 999 180 E 956 /310 /447 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.017 F - Aif Wind reactions based on MWFRS Des Ld: 40.00 J EXP:D HORZ(TL): 0.020 F - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.901 Bearing A Fcperp=565psi. Load Duration: 1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.977 Spacing:24.04 MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.337 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 259 -1122 C-D 0 0 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 333 -737 Lumber Loading Value Set: 13B(Effective 6/1/2013) Truss passed check for 20 psf additional bottom Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 chord live load in areas with 42"-high x 24"-wide Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#1 :B2 2x4 SP M-31: clearance. A-F 729 -339 F-E 515 245 Webs 2x4 SP#3 Bottom chord checked for 10.00 psf non-concurrent Lumber value set"13B"uses design values live load. 9 Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Truss designed for unbalanced load using 0.00/1.00 Webs Tens.Comp. Webs Tens. Comp. windward/leeward factors. Bracing B-F 276 -62 C-E 401 -841 (a)Continuous lateral restraint equally spaced on Wind F-C 447 -147 D-E 112 145 member. Wind loads based on MWFRS with additional C&C member design. Plating Notes Right end vertical not exposed to wind pressure. (")5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning Additional Notes requirements. The overall height of this truss excluding overhang is Plate positions consider a 0.50 inch truss perimeter 7-1-14. edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 18.33 BC 96 0.06 18.33 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others NOTES: Ir- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 /f /\ APEX TrueHouse PE No Michael 60839G Kozlowski Ph No.58544 on PE No.71457y APE Na 7 69311 • 76238 Ply:1 SEQN:17560/T24/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T21 4/ Wgt:111.3 lbs ... / ... 07/19/2018 5'11'8I 12'3'8 I 18'4' 5'11'8 6'4' 6'0'8 /58X7(") m5CX5 m W3X4((") D iiilli. 1u 12 10.25 Tll 5X7(-)A ��713 ■� ot„ 10 't'2 C G F 420E 113X4 r=5X7(") m4X8(") 1 18'4' 1 6.1.4 5'10'12 6'4' I- 6'1'4 I 12' I 18,4. -I Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.041 F 999 240 A 1852 /602 /- /- /- /4.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA 4/VERT(TL): 0.126 F 999 180 E 2090 /640 /- /- /- /- BCDL: 10.00Risk Category:II Snow Duration:NA HORZ(LL): 0.020 E - 4i Wind reactions based on MWFRS Des Ld: 40.00 J EXP:D __ HORZ(TL): 0.040 E - - A Min Brg Width Req= 2.2 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.811 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.987 Spacing:24.0 J MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.833 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 750 -2301 C-D 0 0 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 B-C 540 -1775 Lumber Purlins Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2:T2 2x4 SP SS: to laterally brace chords as follows: Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#1 :B2 2x4 SP SS: Chord Spacing(in oc) Start(ft) End(ft) A-G 1608 -504 F-E 1745 -544 Webs 2x4 SP#3 TC 24 0.00 18.33 G-F 1622 -504 :Lt Wedge 2x6 SP#2: BC 102 0.06 18.33 Apply purlins to any chords above or below fillers Lumber value set"13B"uses design values at 24"OC unless shown otherwise above. Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Hangers/Ties Bracing (J)Hanger Support Required,by others B-G 507 19 C-E 727 -2334 (a)Continuous lateral restraint equally spaced on B-F 202 -46 D-E 169 -314 member. Loading F-C '02 0 Special Loads Bottom chord checked for 10.00 psf non-concurrent live load. (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) TC:From 33 plf at 0.00 to 33 plf at 18.33 Wind BC:From 10 plf at 0.00 to 10 plf at 18.33 TC: 200 lb Conc.Load at 1.90 Wind loads and reactions based on MWFRS. TC: 128 lb Conc.Load at 3.90 Right end vertical not exposed to wind pressure. TC: 204 lb Conc.Load at 5.90,7.90,9.90,11.90 13.90,15.90,16.40 Additional Notes BC: 143 lb Conc.Load at 1.90 The overall height of this truss excluding overhang is BC: 163 lb Conc.Load at 3.90 5-7-14. BC: 156 lb Conc.Load at 5.90,7.90,9.90,11.90 13.90,15.90,16.40 Plating Notes (")5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. NOTES: 111- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (ilil) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fit\ APEX TrueHouse PE No l 0839z1owski ffrey P No 58544 on PE PE No Murray1457APE No.77693 Russell9 76238 Ply:1 SEQN:17571/T18/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T224 Wgt:92.4 lbs ... / ... 07/19/2018 F- 3'5"14 'f' 11'2"7 + 186 8 3'5"14 7'8 "9 74"1 y 5X7("`) =3X8T2 1114X5(") 8 C D 10.25 Z T (a) v m4X5(•.) 1 tr1"z Igill G F 82 E 1113X4 =5X7(") 1115X7(") r 18'6"8 - - 3'7"10 ` 7213 { 781 3'7"10 10'10"7 18'6"8 Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.068 F 999 240 A 1218 /512 /- /- /- /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA J VERT(TL): 0.211 F 999 180 E 1289 /558 /- /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.022 E - J Wind reactions based on MWFRS Des Ld: 40.004 EXP:D HORZ(TL): 0.045 E - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.660 Bearings A&E Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.987 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.766 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 701 -1660 C-D 15 -37 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 873 -2034 Lumber Purlins Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Maximum Bot Chord Forces Per Ply(lbs) to laterally brace chords as follows: Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#22:B2 Top chord 2x4 SP B2T2 2x4 SP S Chord Spacing(in oc) Start(ft) End(ft) 2x4 SP#1:: TC 24 0.00 18.54 A-G 1222 -521 F-E 2029 887 Webs 2x4 SP#3 BC 78 0.15 18.54 G-F 1233 -520 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Maximum Web Forces Per Ply(lbs) Bracing Wind Webs Tens.Comp. Webs Tens. Comp. (a)Continuous lateral restraint equally spaced on Wind loads and reactions based on MWFRS. B-G 239 0 C-E 947 -2162 member. B-F 867 -381 D-E 193 -291 Right end vertical not exposed to wind pressure. F-C 177 0 Special Loads Additional Notes (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) The overall height of this truss excluding overhang is TC:From 33 plf at 0.00 to 33 plf at 18.54 3-4-14. BC:From 10 plf at 0.00 to 10 plf at 18.54 TC: 109 lb Conc.Load at 2.06 TC: 116 lb Conc.Load at 4.06,6.06,8.06,10.06 12.06,14.06,16.06,17.56 BC: 128 lb Conc.Load at 2.06 BC: 68 lb Conc.Load at 4.06,6.06,8.06,10.06 12.06,14.06,16.06,17.56 Plating Notes (")5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Loading Bottom chord checked for 10.00 psf non-concurrent live load. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if"\ APEX 1'rueHouse PE No l 08391owski JPErNo 58544 on PE No. Murray1457APE No.7769311 76238 Ply:1 SEQN:17572/T35/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T23✓ Wgt:93.8 lbs ... / ... 07/19/2018 35"14 9'3" 160"2 18'6" l"' 3'5"14 -I 5'9"2 I 5'9"2 i"" 3'5"14 'I 4X8("") 1113X4 =4X8("") C D T2 E TC sr 12 10.25 V o 4X5(..)(1)8 Nse4XS*.)(l) o I sz INosiNx10'1"2 H A =H0510("") G r 18'6" i I-1,9„5 I- 9'3" I- 93" _I 1'9"5- 9'3" 18'6" Loading Criteria(pat) Wind Criteria Snow Criteria(Pg,Pf in PSP) DeflCSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA .VERT(LL): 0.072 D 999 240 B 1821 /641 /- /- /- /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.225 D 999 180.F 1804 /633 /- /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.018 C - 4/Wind reactions based on MWFRS Des Ld: 40.004/ EXP:D HORZ(TL): 0.037 C - - B Min Brg Width Req= 2.1 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= 2.1 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.851 Bearings B&F Fcperp=565psi. Load Duration:1.15 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.975 Spacing:24.0"0 MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.589 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 83 -40 D-E 929 -2865 Wind Duration: 1.60 WAVE,HS VIEW Ver:18.01.008.0430.21 B-C 752 -2088 E-F 736 -2065 Lumber Purlins C D 929 -2865 F-G 83 -40 Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Top chord 2x4 SP#2:T2 2x4 SP#1: to laterally brace chords as follows: Maximum Bot Chord Forces Per Ply(lbs) Bot chord 2x4 SP SS Chord Spacing(in oc) Start(ft) End(ft) Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP#3 TC 24 -1.78 20.28 B-H 1536 -532 H-F 1514 -518 BC 105 0.15 18.35 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Maximum Web Forces Per Ply(lbs) Special Loads Loadin 9 Webs Tens.Comp. Webs Tens. Comp. (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Bottom chord checked for 10.00 psf non-concurrent C-H 1521 -450 H-E 1546 -465 TC:From 66 plf at -1.78 to 66 plf at 2.06 live load. D-H 449 -846 TC:From 33 plf at 2.06 to 33 plf at 16.44 TC:From 66 plf at 16.44 to 66 plf at 20.28 Wind BC:From 5 plf at 1.78 to 5 plf at 0.00 Wind loads and reactions based on MWFRS. BC:From 10 plf at 0.00 to 10 plf at 18.50 BC:From 5 plf at 18.50 to 5 plf at 20.28 Additional Notes TC: 109 lb Conc.Load at 2.06,16.44 TC: 116 lb Conc.Load at 4.06,6.06,8.06,8.44 The overall height of this truss excluding overhang is 10.44,12.44,14.44 3-4-14. BC: 128 lb Conc.Load at 2.06,16.44 Top Chord overhang(s)may be field trimmed. BC: 68 lb Conc.Load at 4.06,6.06,8.06,8.44 10.44,12.44,14.44 Plating Notes (I)-plates so marked were sized using 0% Fabrication Tolerance,0 degrees Rotational Tolerance,and/or zero Positioning Tolerance. (")5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (.11'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ,f*/\ APEX TrueHouse PE No Michael 08391owskiJeffrey No 58544 Arneson PEPE No. Murray7457PE No 7769311 76238 Ply:1 SEQN: 17569/T4/COMN Custom-Roick Res. Qty: 5 FROM: DRW: T24 i Wgt:75.6 lbs ... / ... 07/19/2018 F s'a° -I- 16'8 -I '" 8'4° CO'5x5(••) _ Imo. 12 8 jo 11111111111111116. =3X463 1 T)B �8X4(B1 T) FL. 6" _08'6'10 F A .5X7(••) E L r 16'8" -j F-2' I 84" I I 2'--I 84" 16'8" Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL): 0.011 F 999 240 B 984 /266 /579 /- /320 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.039 F 999 181 D 985 /266 /579 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.015 F - g/ Wind reactions based on MWFRS Des Ld: 40.00 J EXP:D HORZ(TL): 0.029 F - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 D Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.787 Bearings B&D Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.999 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.170 Maximum Top Chord Forces Per Ply(lbs) J C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 84 0 C-D 322 -1004 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 B-C 321 -1005 D-E 84 0 Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#1 member design. Chords Tens.Comp. Chords Tens. Comp. Botchord2x4SP#2 B-F 694 -136 F-D 694 -136 Webs 2x4 SP#3 Additional Notes Lumber value set"136"uses design values The overall height of this truss excluding overhang is Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC 6-7-14. Top Chord overhang(s)may be field trimmed. Webs Tens.Comp. Plating Notes C-F 446 0 (")2 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 18.67 BC 107 0.15 16.52 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if"\ TrueHouse PE No.Michael 60839 lowski Jeffrey 58544son PE urra PE No.Derek B71457y Adam K PE No.Russell6 APEX 76238 Ply: 1 SEQN:17570/T38/COMN Custom-Roick Res. Qty: 2 FROM: DRW: T25 J Wgt:60.2 lbs ... / ... 07/19/2018 810' I 13'8' 810' 610' C,4X4(") 111 T 12 Zo 9 v- ii,m v 3X4(81 T)B Drs 3X4(81 T) i �� 0 10'1'2 F q N3X4 E 1 13'8" I 2 6'10' 6'10' 6'10. I 13'8. I- 2' Loading Criteria(pst) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL): 0.006 F 999 240 B 733 /226 /505 /- /280 /4.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.023 F 999 180 D 733 /226 /505 /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.009 F - J Wind reactions based on MWFRS Des Ld: 40.00d EXP:D HORZ(TL): 0.016 F - - B Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 D Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.596 Bearings B&D Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.807 Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.115 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 84 0 C-D 255 -665 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 B-C 254 -665 D-E 84 0 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 5-6-6. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. B-F 441 -127 F-D 441 -127 Webs 2x4 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Plating Notes C-F 301 0 (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 15.67 BC 120 0.15 13.52 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (IrrH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX T'rueHouse PE No.Michae160 39lowskirey P Nc 58544 Arneson PEPE No.71457y Adam PE No.7 69311 76238 Ply:1 SEQN:17575/T45/COMN Custom-Roick Res. Qty: 2 FROM: DRW: T26✓ Wgt:60.2 lbs ... / ... 07/19/2018 64'.8 129" 6'4"8 6'4"8 C/4X4(") /► 12 9 7 in 0 3X4 8 D 44 3X4 13x6(");� i;:3x * I. 10 2 13X4 A 12'9" 1 6'4"8I 6'48 6'4"8 12'9" Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NAVERT(LL):-0.056 D 999 240 A 542 /165 /324 /- /167 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA V VERT(TL): 0.185 D 999 180 G 542 /165 /324 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.048 B - J Wind reactions based on MWFRS Des Ld: 40.04 EXP:D - _, HORZ(TL): 0.093 B - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 G Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.661 Bearings A&G Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.462 Spacing:24.04 MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.414 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 978 -1173 C-D 264 -580 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 8-C 264 -580 D-E 975 -1170 Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 member design. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 A-F 405 -83 F-E 405 -83 Webs 2x4 SP#3 Additional Notes :Lt Slider 2x4 SP#3:BLOCK LENGTH= 1.500' The overall height of this truss excluding overhang is Ply Maximum Web Forces :Rt Slider 2x4 SP#3:BLOCK LENGTH= 1.500' 5-6-6. y(lbs) Webs Tens.Comp. Lumber value set"13B"uses design values approved 1/30/2013 by ALSC C-F 293 -5 Plating Notes (-)3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 12.75 BC 120 0.00 12.75 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if"\ APEX TrueHouse .PEichNaoel6G08K3o9zlowski Jeffrey Ny 58544 Arneson PEPE No Murray71457 APE o Russell • • 76238 Ply:1 SEQN: 17576/T39/COMN Custom-Roick Res. Qty: 3 FROM: DRW: T29it Wgt:36.4 lbs ... / ... 07/19/2018 2713 5711 F 2'7"13 2,7 13 w3X4(") 12 9 a 1113X4(••)B mT Tr a A ' E l .� lit' IN 8'7'2 ..:F III•X5(") 114 5") 1 S3"11 -i 2 5'3"11 5,3„11 2' Loading Criteria(pst) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.051 C 999 240 G 392 /116 /259 /- /169 /4.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA W VERT(TL): 0.162 C 602 180 F 392 /116 /158 /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.182 B - At Wind reactions based on MWFRS Des Ld: 40.00 Al EXP:D HORZ(TL): 0.224 B - - G Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.474 Bearings G&F Fcperp=565psi. Load Duration: 1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.300 Spacing:24.0 MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.444 Maximum Top Chord Forces Per Ply(lbs) J C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 84 0 C-D 144 -143 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 145 -143 D-E 84 0 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) 3-10-12. Chords Tens.Comp. Top chord 2x4 SP#2 Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. G-F 91 -72 Webs 2x4 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Plating Notes B-G 302 -337 D-F 298 -337 (")5 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.00 7.31 BC 64 0.00 5.31 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111..11.1- 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer JfV\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 TrueHouse MichaePE No.160 3g Kozlowski Jeffrey Arneson PE Derek No. Murray1457Adam K PE No.7769311 APEX • • 76238 Ply:1 ' SEQN:17579/T54/COMN Gusto -Roick Res. Qty: 4 FROM: DRW: T30 Ar Wgt:77.0 lbs ... / ... 07/19/2018 I 2'6"5 I 8'10' I 15'x'11 I 178" I 2'6"5 6'3"11 6'3"11 2'6"5 C/6X8("") _ I�, 12 m 9 m m 0 �4X5(B7)B Dim4X5(81) F T II3x4 A E m _ ts. _t_ 16'2'2 1 17'8" 1 2'6"5 6'3"11 6'3"11 I2,6,5 I 8'10„ I 16111 I � �p Loading Criteria(psf) Wind Criteria Snow Criteria(P f in SF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA • PP flaflai4inn in Inr deft U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.276 F 749 240 AL 751 /308 /401 / /235 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.898 F 352 180 G 751 /308 /401 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HUHL(LL): 0.207 F - 4, Wind reactions based on MWFRS Des Ld: 40.04 EXP:D HORZ(TL): 0.441 F - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:19.91 ft Code/Misc Criteria Creep Factor:2.0 G Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.577 Bearings A&E Fcperp=565psi. Load Duration:1.15 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.611 Spacing:24.0"4, MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.104 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 232 -440 C-D 417 -954 Wind Duration:1.60 WAVE VIEW Ver.18.01.00B.0430.21 B-C 417 -954 D-E 232 -440 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x6 SP SS Dense 7-0-8. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 B-F 851 -176 F-D 851 -176 Webs 2x4 SP#3 Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Webs Tens.Comp. Plating Notes C-F 272 0 (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.53 15.14 BC 120 0.06 12.55 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. 61) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ Michael G Kozlowski Jeffrey P Amason Derek B Murray Adam K Russell APEX TrueHouse PE No 60839 PE No 58544 PE No.71457 PE No.77693 a • 76238 Ply:1 SEQN:17580/T49/COMN Custom-Roick Res. Qty: 2 FROM: DRW: T31 4/ Wgt:77.0 lbs ... / ... 07/19/2018 I 2'6"5 I 8.10' I 1511 1 1I 17'1"8 1 2'6'5 63"11 6'3"1 1 1'11"13 C/6X8(") I 111 T 0 n 0 F-. 4X4(—)B Dm4X4(..) II7 11111 I at o F TTI' co 113X4 , i,1. S. A 11 7ya 16.72 1 i 16'2'2 r 171"8 i ���111111 2'6"5 I 6'3"11 I 6'3"11 i 1'1113 I 2.6"5 8'10" 15111 17'1"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA I VERT(LL): 0.246 F 815 240 A 727 /298 /391 /- /233 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA �I VERT(TL): 0.798 F 383 180 E 728 /296 /390 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.191 F - 4 Wind reactions based on MWFRS Des Ld: 40.00 4, EXP:D HORZ(TL): 0.406 F - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:19.91 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.555 Bearing A Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.602 Spacing:24.04 MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.105 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 187 -426 C-D 357 -922 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 345 -894 D-E 199 -426 Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x6 SP SS Dense member design. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 B-F 792 -146 F-D 792 -146 Webs 2x4 SP#3 Additional Notes Lumber value set"13B"uses design values The overall height of this truss excluding overhang is Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC 7-0-8. Webs Tens.Comp. Plating Notes C-F 274 0 (")3 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 -2.53 14.60 BC 120 0.06 12.55 Apply puffins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: 11- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 if*/\ APEX TrueHouse PE No.Michael 08391owski JeffreyP Arneson PE No.1457y APE No.7769311 a • 76238 Ply:1 SEQN:17582/T58/COMN Custom-Roick Res. Qty: 2 FROM: DRW: T324 Wgt:123.2 lbs ... / ... 07/19/2018 8'8" 1611"8 "8 B/4X5(") - ZION 9 7 o_ in in =3X4(")A Cm-4X4(") _L l 1/////// R// ///X//////Mr/'///////////////////a//////// 017.1,. F'moi E D 8X8(") j 1611'8 j 8'8" -I 83 8 H8'8" 16'11"8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA 4, VERT(LL): 0.126 E 999 240 F 674 /204 /354 /- /171 /4.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.377 E 809 180 D 680 /226 /329 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.010 B - Al Wind reactions based on MWFRS Des Ld: 40.04 EXP:D -- HORZ(TL): 0.025 B - - F Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:20.81 ft Code/Misc Criteria Creep Factor:2.0 D Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.638 Bearing F Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.351 Spacing:24.0 MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.284 Maximum Top Chord Forces Per Ply(lbs) J C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 451 -1093 8-C 448 -1093 Wind Duration:1.60 WAVE VIEW Ver:18.01.00B.0430.21 Lumber Loading Maximum Bot Chord Forces Per Ply(lbs) Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent Chords Tens.Comp. Chords Tens. Comp. Top chord 2x4 SP#2 live load. F-A 171 -171 E-C 780 -229 Bot chord 2x6 SP SS Dense Truss designed for unbalanced load using 0.00/1.00 A-E 780 -229 C-D 0 0 Webs 2x4 SP#3 windward/leeward factors. Lumber value set"13B"uses design values Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC Wind Webs Tens.Comp. Wind loads based on MWFRS with additional C&C Plating Notes member design. B-E 745 -200 (")4 plate(s)require special positioning.Refer to Additional Notes scaled plate plot details for special positioning requirements. The overall height of this truss excluding overhang is Plate positions consider a 0.50 inch truss perimeter 5-3-10. edge distance. Tray Scab(s) (1)2x6x10-2-0 x SP SS Dense scab at left end. Attach scab to face of chord with:0.131"x3",min. nails @ 8"oc,plus additional nail clusters at:BRG.: (3),heel:(4),1st panel point:(0). (1)2x6x9-9-8 x SP SS Dense scab at right end. Attach scab to face of chord with:0.131"x3",min. nails @ 8"oc,plus additional nail clusters at:BRG.: (3),heel:(4), 1st panel point:(0). Purlins In lieu of structural panels or rigid ceiling use puffins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 2.45 14.88 BC 120 0.00 16.96 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (1111F1141"- 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer ""\ Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 APEX TrueHouse PE No Michael 08391owskiJeffrey No 58544 on PEPE No Murray1457PE No.77769311 76238 Ply:1 SEQN:17585/T75/COMN Custom-Roick Res. Qty: 2 FROM: DRW: T33 4/ Wgt:99.4 lbs ... / ... 07/19/2018 4'4"13I 8'8" I 12'11"3 I 16'11"8 4'4"13 4'3"3 4'3"3 4'0"5 0=4X4 12 A;1 9 0 ,— 13X4('")Zn to A /5X7(,)B \5X7(..) 13X4 ) ,N L I :: 017'11- G F III•X:("") =5X7('") 1113X8("') 1 1611"8 A 8'8" } 8'3"8 "I 8'8" 16'11"8 Loading Criteria(pst) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA _,VERT(LL): 0.044 G 999 240 H 721 /314 /378 /- /113 /4.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.141 G 999 180 F 721 /314 /379 /- /- /- BCDL: 10.00Risk Category:II Snow Duration:NA HORZ(LL): 0.016 F - J Wind reactions based on MWFRS Des Ld: 40.00 If EXP:D HORZ(TL): 0.034 F - - H Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:21.62 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.345 Bearing H Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.963 Spacing:24.0W MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.584 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): , A-B 6 -34 C-D 410 -899 Wind Duration:1.60 WAVE VIEW Ver.18.01.00B.0430.21 B-C 410 -899 D-E 5 -28 Lumber Wind Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 member design. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 End verticals not exposed to wind pressure. H-G 1254 -626 G-F 1184 -591 Webs 2x4 SP#3 Lumber value set"13B"uses design values Additional Notes Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp. 5-3-10. Plating Notes A-H 121 -148 G-D 373 -560 (")7 plate(s)require special positioning.Refer to H-B 669 -1325 D-F 642 -1272 scaled plate plot details for special positioning B-G 412 -635 E-F 111 -135 requirements. C-G 680 -240 Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 16.96 BC 93 0.00 16.96 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Hangers/Ties (J)Hanger Support Required,by others Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. NOTES: II- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (ervii) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ APEX TrueHouse PE No l 0838lowskirey P No 58544 Arneson PEPE No Murray1457PE No.77 93f1 76238 Ply:1 SEQN:17586/T79/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T34 i Wgt:107.8 lbs ... / ... 07/19/2018 6'4'1 I 8'8" I 10'11'15_I 16'11"8 6'4'1 2'3'15 2'3'15 5'11'9 12 9 7 C=4X4 iN W3X4(") 13X4(") A /5X5(..) /•••101D\5X5(..) E TI ro io 1 -11-I,_ :: (1711" G F I X:(") =5X7("") 13X8("") A 16'11'8 j I 88 I 83'8 I 8'8" 16'11'8 Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA 4 VERT(LL): 0.031 G 999 240 H 721 /268 /372 /- /60 /4.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.100 G 999 180 F 721 /264 /373 /- /- /- BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.011 F - gif Wind reactions based on MWFRS Des Ld: 40.00/ EXP:D HORZ(TL): 0.024 F - - H Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:22.35 ft Code/Misc Criteria Creep Factor:2.0 F Min Brg Width Req= - Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.748 Bearing H Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.867 Spacing:24.0 MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI: 0.912 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 12 -27 C-D 405 -848 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 405 -848 D-E 11 -23 Lumber Hangers/Ties Value Set:13B(Effective 6/1/2013) Recommended hanger connections are based on Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 manufacturer tested capacities and calculations. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 Conditions may exist that require different H-G 872 -435 G-F 851 -423 Webs 2x4 SP#3 connections than indicated.Refer to manufacturer publication for additional information. Lumber value set"13B"uses design values MaximumWebForcesPer approved 1/30/2013 by ALSC Bearing at location x=16'8"8 uses the following Ply(lbs) ) support conditions:16'8"8 Webs Tens.Comp. Webs Tens. Comp. Plating Notes Bearing F (16'8"8,17'11")LUS26 A-H 171 -215 G-D 245 -342 Supporting Member:(2)2x6 SP#2 (")7 plate(s)require special positioning.Refer to (4)0.148"x3"nails into supporting H-B 476 -950 D-F 470 -944 scaled plate plot details for special positioning member, B-G 266 -378 E-F 161 -202 requirements. (3)0.148"x3"nails into supported C-G 784 -341 Plate positions consider a 0.50 inch truss perimeter member. edge distance. Wind Purlins Wind loads based on MWFRS with additional C&C In lieu of structural panels or rigid ceiling use purlins member design. to laterally brace chords as follows: End verticals not exposed to wind pressure. Chord Spacing(in oc) Start(ft) End(ft) TC 24 0.00 16.96 BC 120 0.00 16.96 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Additional Notes The overall height of this truss excluding overhang is 5-3-10. NOTES: 1_This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03, should be used in conjunction with the architectural plans during installation. (111rTH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer J� Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX T�rueHouse PE No 60839 PE No 58544 PE No.71457 PE No.77693 A A 76238 Ply:2 SEQN:17593/T16/COMN Custom-Roick Res. Qty: 1 FROM: DRW: T35 f Wgt:210.0 lbs / ... 07/19/2018 2'6.66'4" 10x9 12'8" M' 2'6"6 I 3'9"9 I 3,9'9 I 2'6"7 -I C 9x6(") 12 ������ m7. =8(811(S1 ����� -6pX8(B1) ``, \\ T I F 1113X4 e ;141 1 ` �` 116'2'2 r12'8" A 2'6'63'9'9 3'9'9 I' 2'6"6 I 6'4' I 10'1'9 I P Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Inc R Ill Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA _/ VERT(LL): 0.211 F 694 2401 A 2816 /1311 - /- /- /4.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.602 F 360 180 E 2816 /1311 - /- /- /4.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.156 F - A, wino reactions based on MWFRS Des Ld: 40.00 EXP:D HORZ(TL): 0.300 F - A Min Brg Width Req= 1.8 NCBCLL: 10.00 Mean Height:19.15 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= 1.8 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.764 Bearings A&E Fcperp=565psi. Load Duration: 1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.575 Spacing:24.0'J MWFRS Parallel Dist:0 to h/2 Rep Factors Used:No Max Web CSI: 0.229 Maximum Top Chord Forces Per Ply(lbs) C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 391 -840 C-D 675 -1533 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 B-C 675 -1533 D-E 391 -840 Lumber Purlins Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x8 SP#1 to laterally brace chords as follows: Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x6 SP#2 Chord Spacing(in oc) Start(ft) End(ft) B-F 1639 -718 F-D 1639 -718 Webs 2x4 SP#3 TC 24 -2.53 10.13 BC 88 0.12 7.47 Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers Maximum Web Forces Per Ply(lbs) approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Webs Tens.Comp. Nailnote Wind C-F 600 -244 Nail Schedule:0.131"x3",min.nails Wind loads and reactions based on MWFRS. Top Chord:1 Row (012.00"o.c. Bot Chord:1 Row @ 4.25"o.c. Additional Notes Webs :1 Row @ 4"o.c. (1)2x8x8-1-3 x SP#1 Top chord scab centered Use equal spacing between rows and stagger nails 3-3-4 from left end.Attach to one face of chord with in each row to avoid splitting. (4)rows of 0.131"x3",min.nails @ 6"oc,staggered Special Loads 3". (Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) (1)2x8x8-1-3 x SP#1 Top chord scab centered TC:From 65 plf at 0.00 to 65 plf at 4.39 9-4-11 from left end.Attach to one face of chord with TC:From 33 plf at 4.39 to 33 plf at 8.27 (4)rows of 0.131"x3",min.nails @ 6"oc,staggered TC:From 65 plf at 8.27 to 65 plf at 12.67 BC:From 10 plf at 0.00 to 10 plf at 12.67 The overall height of this truss excluding overhang is BC: 643 lb Conc.Load at 0.39,12.27 5-4-2. BC: 680 lb Conc.Load at 2.39,10.27 BC: 721 lb Conc.Load at 4.39,6.33,8.27 Plating Notes (")1 plate(s)require special positioning.Refer to scaled plate plot details for special positioning requirements. Plate positions consider a 0.50 inch truss perimeter edge distance. NOTES: 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (11.-}1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fi /\ TrueHouse MPE No l 0839 owski Jeffrey 58544 on PEPE No. MurrayDerek B1457Adam K PE No.7769311 APEX r 76238 Ply:1 SEQN:17595/T53/MONO • Custom-Roick Res. Qty: 1 FROM: DRW: T36 Al Wgt:98.0 lbs ... / ... 07/19/2018 4'6"10 9'3" 1a11"6 18'6" 4'6"10 I 4'8"6 I 4'8"6 I- 4'6"10 'I _4X8(") 1113X4 ;4X8("") B C D 1- 12 10.25 V 40 n _ 41110N (7 /- v =3X4(81)A E=3X4(81) T m u l u 0 1(Y1-2 211 H G F I ir 1113X4 =5X7("") III3X4 1 18'6" 1 4'8"6 4'6"10 4'6"10 4'8"6 I4'8„6 I 9,3" I- 13'9„10 I 18,6" 'I Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W TCDL: 10.00 Speed: 130 mph Pf:NA Ce:NA J VERT(LL): 0.023 C 999 240 A 798 /249 /467 /- /141 /6.5 BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.076 C 999 180 E 798 /249 /467 /- /- /6.5 BCDL: 10.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.009 F - 4 Wind reactions based on MWFRS Des Ld: 40.00,, EXP:D HORZ(TL): 0.020 F - - A Min Brg Width Req= 1.5 NCBCLL: 10.00 Mean Height:15.00 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= 1.5 Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.268 Bearings A&E Fcperp=565psi. Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.574 Spacing:24.0' MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.122 Maximum Top Chord Forces Per Ply(lbs) �/ C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi:0.18 Plate Type(s): A-B 423 -996 C-D 488 -929 Wind Duration:1.60 WAVE VIEW Ver:18.01.008.0430.21 • B-C 488 -929 D-E 423 -996 Lumber Additional Notes Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs) Top chord 2x4 SP#2 4-3-12. Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP#2 A-H 684 -211 G-F 687 -209 Webs2x4SP#3 H-G 687 -210 F-E 684 -210 Lumber value set"13B"uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs) Plating Notes Webs Tens.Comp. Webs Tens. Comp. ("")3 plate(s)require special positioning.Refer to B-H 183 0 G-D 321 -146 scaled plate plot details for special positioning B-G 321 -145 F-D 183 0 requirements. C-G 180 -317 Plate positions consider a 0.50 inch truss perimeter edge distance. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) IC 24 0.00 18.50 BC 120 0.15 18.35 Apply purlins to any chords above or below fillers at 24"OC unless shown otherwise above. Loading Bottom chord checked for 10.00 psf non-concurrent live load. Truss designed for unbalanced load using 0.00/1.00 windward/leeward factors. Wind Wind loads based on MWFRS with additional C&C member design. NOTES: r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03, should be used in conjunction with the architectural plans during installation. (111'14 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 ifV\ APEX TrueHouse PE No.l 0839 owski pErey 58544 on PE No 71457y APE No.77 sell