Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
533 ATLANTIC BEACH CT - NEW HOME PERMIT
RESIDENTIAL PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH RES18-0354 VJ* �� 800 SEMINOLE ROAD ISSUED: 11/13/2018 ., %/ JyO';}}` ry ATLANTIC BEACH. FL 32233 EXPIRES: 5/12/2019 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: RESIDENTIAL NEW SINGLE 533 ATLANTIC BEACH CT FAMILY RESIDENCE NEW SINGLE FAMILY $574499.95 TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 169505 1420 ATLANTIC BEACH COUNTRY CLUB UNIT 02 COMPANY: ADDRESS: CITY: STATE: ZIP: CLADDAGH JACKSONVILLE 3997 AMERICA AVE FL 32250 CONSTRUCTORS, INC. BEACH OWNER: ADDRESS: CITY: STATE: ZIP: ROICK JAMES A 2228 OCEANWALK DR W ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list. Container cannot be placed on City right-of-way. 1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5878. Issued Date: 11/13/2018 1 of 3 ao 0 y RESIDENTIAL PERMIT PERMIT NUMBER �_. CITY OF800SEMINNATE BEACH RES18-0354 o :" ISSUED: 11/13/2018 0� ATLANTIC BEACH. FL 32233 EXPIRES: 5/12/2019 2 PUBLIC UTILITIES METER BOX SEWER CLEAN OUT INFORMATIONAL Notes: Ensure all meter boxes,sewer cleanouts and valve covers are set to grade and visible. 3 PUBLIC UTILITIES RT1 SEWER CLEANOUT INFORMATIONAL Notes: A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. 4 PUBLIC WORKS DRIVEWAY APRON INFORMATIONAL Notes: All concrete driveway aprons must be 5 inches thick,4000 psi,with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of-way. 5 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(904-247 -5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 6 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL ' Notes: All runoff must remain on-site during construction. 7 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal, Realco Recycling,Shapells,Inc.,Republic Services,Donovan Dumpsters, Phillips Containers). Container cannot be placed on City right-of-way. 8 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 9 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 10 PUBLIC WORKS MAXIMUM DRIVEWAY INFORMATIONAL Notes: Maximum driveway width within the City right-of-way is 20 feet. FEES ' _i ..-, .� DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $1830.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $915.00 BUILDING PLAN REVIEW RESUBMITTAL SECOND 455-0000-322-1006 0 $50.00 CROSS CONNECTION 400-0000-343-3701 1 $50.00 PU REVIEW RESIDENTIAL BLDG 001-0000-329-1007 0 $50.00 Issued Date: 11/13/2018 2 of 3 lr1' �'%,\ RESIDENTIAL PERMIT PERMIT NUMBER ^��� � RES18-0354 . CITY OF ATLANTIC BEACH 'y ISSUED: 11/13/2018 800 SEMINOLE ROAD 4.0'; >r ATLANTIC BEACH. FL 32233 EXPIRES: 5/12/2019 PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 SEWER SYSTEM DEVELOPMENT CHARGE 415-0000-324-0301 0.75 $4050.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $41.93 STATE DCA SURCHARGE 455-0000-208-0600 0 $27.95 WATER METER ONLY DOMESTIC 400-0000-343-3301 0 $185.00 WATER METER ONLY RECLAIM 400-0000-343-3301 0 $185.00 WATER SYSTEM DEVELOPMENT IMPACT CHARGE 415-0000-324-0301 0.75 $1140.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $50.00 TOTAL: $8,699.88 Issued Date: 11/13/2018 3 of 3 ,p,Anrlr, City of Atlantic Beach APPLICATION NUMBER `i , p. .*0 Building Department (To be assigned by the Building Department.) "‘' AT i 800 Seminole Road /� /� [� 4 1.:)-:.- 5845 �- _ n Atlantic Beach, Florida 32233 5445 r' J �7 Phone(904)247 5826 Fax(904)247 5845 J "LU o;1t9r E-mail: building-dept@coab.us Date routed: I / 1 62:41 ej City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM C�- Property Address: , .33 I�4-Y. e--6Q Department review required Yes No i ^ i ildin Applicant: e_ 1 Q,.cick e 0j�'t5�. K.K.—Planning &Zoning Tree Administrator Project: IQ et-AD S (n f�„ Sccr ( blic Wori<, Public Utilities Public Safety Fire Services Review fee $ Dept Signature i Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District • Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: /Approved. Denied. Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONINGfa-, - - Ig Reviewed by: Date: � TREE ADMIN. Second Review: ( 'Approved as revised. ( (Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. I Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 �i�L�ific, City of Atlantic Beach APPLICATION NUMBER 6s kBuilding Department (To be assigned by the Building Department.) • - ' -i 800 Seminole Road I � . RE- -- 0354- \!:)_:,.. Beach, Florida 32233 5445 Phone(904)247-5826 • Fax(904)247-5845 I ¢ j;1t�r I E-mail: building-dept@coab.us Date routed: U i B l C7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM C.-(- Property Address: 33 Pk"+late+ Q—�Q�` Department review required Yes No din _ Applicant: C__ t 0.t%(11 c h C O rt -.(-. anning &Zoning Tree Administrator Project: eGo S (!1 e_ Sccr-- ( t,i, -11--ublic Work Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ['Approved. PKenied. Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: / i,/y1 y Date: /0-1C3'-1 k TREE ADMIN. Second Review: A roved as revised. ❑ pp ['Denied. Not applicable PUBLIC WORKS Comments: • PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: nApproved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 rj ,\J�lj \ ()FRC ,P COPY CITY OF ATLANTIC BEACH 2 800 Seminole Road ir, • =,, Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date tt/f/jf Revision to Issued Permit Corrections to Comments Permit# R6-15/Y-033-V- , Project c5/ D3S4-- Project Address 533 %L7Z A'v77c_ � c�t �, ,�7- Contractor/Contact Name /174-r7— Phone 174-r7 Phone `1 v f---513 - i 7 Z_Y Email C Ia.o/22.; 4 :n rr ; Description of Proposed Revision/Corrections: Permit Fee D e$ ,S C', 6O /Z.e_vo Az,.c.,,-o0.6.4.0-p-f 09re-we—, -�- Le 7`rte t. pi vwte.a i / Lky'i v- 3 t c Z9i? qtr- .- iF i��,a /'ee. -a c-4,3 Additional Increase in Building Value$ Additional S.F. By signing below,I 01 4-71ti e..J 1. / rt <i(4 affirm the Revision is inclusive of the proposed changes. (printed name) 1/0-' 7L- `7-c ---v-'`41( I ///b Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Ali lQfV,rG- Car',wNPw./i /441/4 b.Fae h fr"-t 1 Department Review Required: �uildin� f?"\ Planning &Zoning Reviewed By Tree Administrator e-Publinor �� Public Utilities �t Public Safety Date Fire Services f�I CITY OF ATLANTIC BEACH _ r 800 SEMINOLE ROAD y yy ATLANTIC BEACH, FL 32233 (904) 247-5800 \JS3l9r BUILDING REVIEW COMMENTS Date: 10/30/2018 Permit#: RES18-0354 Site Address: 533 ATLANTIC BEACH CT Review Status: denied RE#: 169505 1420 Applicant: CLADDAGH CONSTRUCTORS, INC. Property Owner: ROICK JAMES A Email: mattcladdagh@yahoo.com Email: TAROICK@ICLOUD.COM Phone: 9042411012 Phone: 9049232379 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Submit 2 copies of the ICC-ESR report for the spray foam insulation to be used. 2. Read, review and discuss Chapter 39 of the 6th Edition 2017 FBC-Residential, with the electrician and homeowner. Confirm in writing that requirements for quantities of and spacing requirements for receptacles serving kitchen countertops, islands countertops and peninsular countertops,will be followed and adhered to. The alternative method to meet the requirements of spacing at kitchen countertops, due to the lack of backsplash space, will be the UL listed pop-ups mounted on the countertop surface. This statement concerning pop-ups need not apply to peninsular countertops or island countertops. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 904.247.5844 Email:mjones@coab.us j71ggifed f?PllrfI.v, Comv in. k 10/ 30/a0/ 012/ Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding". The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. 0!--vire, City of Atlantic Beach ficEI APPLICATION NUMBER � Building Department VE be assigned by the Building Department.) 800 Seminole Road r ,�:.,_ �� Atlantic Beach, Florida 32233 5445 OCT 1 8 2018 R i A 0.35 4 Phone(904)247-5826 Fax(904)247-5845 / "LJg0�Y E-mail: building-dept@coab.us BY. ate routed: 1 C) I Bit IS City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM a+ Property Address: 33 . `' \ 4 Q.f Q� Department review required Yes No ildin- ' Applicant: CI, L ,Act 0, k C .f,4_- manning & Zoning Tree Administrator Project: 't✓it� S (7,(1,.... F,,,,,,-, I blic Work Public UtilitiesT ) Public Safety Fire Services, Review fee $ 4`2,O Dept Signature GCI/ Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI AfION STATUS Reviewing Department First Review: Approved. I 'Denied. I 'Not asplicable (Circle one.) Comments: BUILDING r VI5400 tale.iv LasfAcie PLANNING & ZONING Reviewed by: Date:10'/9-',---- TREE ADMIN. Second Review: Approved as revis d. Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. I 'Not applicable Comments: • Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach '"' PUBLIC UTILITIES DEPARTMENT ‘,�OI902 Assisi Lane // Jacksonville, FL 32233 '''1,9 ,% (904) 247-5834 NEW WATER / SEWER TAP REQUEST fNumbDate /0—/?— / 8 Service Address 533 <17/.la�/T/L 3cii C71---- Number er of Units I Commercial Residential 17 Multi-Family 3'//7 New Water Tap(s) & Meter(s) Meter Size(s) New Irrigation Meter Upgrade Existing Meter from to (size) 3 '` New Reclaim Water Meter V Size ly New Connection to City Sewer Applicant Name Billing Address City State Zip Phone Email Applicant Signature CITY STAFF USE ONLY Application # a5 ( e - 035Y Water System Development Charge $ !t / yv , O Sewer System Development Charge $ CI, CAV . cz Water Meter Only $ /07 CIV Reclaim Meter Only $ /6 6-, ciO Water Meter Tap $ Sewer Tap $ Cross Connection $ so, OU Other $ TOTAL $ .' '/tO, CO (Notes) APPROVEDy .f .:.? �� _� Date .40.--/ 7 P lic Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED riy>,��f,,, City of Atlantic Beach APPLICATION NUMBER rs ' Building Department - ,-,.ssigned by the Building Department.) -) 800 Seminole Roadiv) (� /J �� Atlantic Beach, Florida 32233-5445 8 {� `'�" Phone(904)247 5826 • Fax(904)247-5845 OCT � 018 ¢ 01110- E-mail: building-dept@coab.us D. y outed: IC) / i �j l U ii- Cit web-site: http://www.coab.us BY APPLICATION REVIEW AND TRACKING FORM e,4- Property Address: 33 P4 laA4 0....60_0,-0-11 Department review required Yes No ;11uildirig_ Applicant: C OLACI- C1'1 e. .„,4_, &Zoning Tree Administrator Project: N 'e,O S „-q, ro,..„ , ,Public Work5Public Utilities' ublic Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. V enied. Not applicable (Circle one.) Comments: BUILDING c)1(av►S '1v0 lye. 'VD Lasts-FcHe PLANNING &ZONING / 11411, Reviewed by Date: / © TREE ADMIN. Second Review: /Approved as revised. ' 'Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: /,"":2--/1 FIRE SERVICES Third Review: I 'Approved as revised. riDenied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 j ,`'; ' `.`' CITY OF ATLANTIC BEACH Department of Public Works ,....* 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 PUBLIC WORKS PLAN REVIEW COMMENTS Date: 10/24/18 Applicant: Claddagh Constructors, Inc. Permit#: RES18-0354 Email: claddaghmatt@gmail.com Review Status: DENIED Property Owner: Tami &James Roick Site Address: 533 Atlantic Beach Court Email: taroick@icloud.com THIS PLAN REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS Correction Items must be submitted to the Building Department at 800 Seminole Road. Submittals that respond to only one or a few correction items will not be accepted. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions must be submitted to the Building Department and must respond to EACH department review. PUBLIC WORKS CORRECTION ITEMS: • A Revocable Encroachment Agreement must be submitted. i/ - P The form is on our website under Building Department - "Permit Applicatio nd Forms" and also at the Building Department located at City Hall. PUBLIC WORKS CONDITIONS OF APPROVAL: (The following comments will be printed on your permit as Conditions of Approval) • All concrete driveway aprons must be 5" thick, 4000 psi, with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of-way. • Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (247-5814) to request an Erosion and Sediment Control Inspection prior to start of construction. • All runoff must remain on-site during construction. • Roll off container company must be on City approved list (Advanced Disposal, Realco Recycling, Shapells, Inc., Republic Services, Donovan Dumpsters, Phillips Containers). Container cannot be placed on City right-of-way. • Full right-of-way restoration, including sod, is required. • All runoff must remain on-site. Cannot raise elevation. • Maximum driveway width within the City right-of-way is 20'. Scott Williams, Public Works Director swilliams@coab.us/904-247-5834 Page 1 of 2 0:\Public Works\ADMIN\PLAN REVIEW COMMENTS\RE518-0354(Claddagh).docx Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding". The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings. The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. Page 2 of 2 O:\Public Works\ADMIN\PLAN REVIEW COMMENTS\RES18-0354(Claddagh).docx rj"\' J ���� 3 r �� CITY OF ATLANTIC BEACH s- ,`,»" f NOV 2 201B 800 Seminole Road ii �'v • Atlantic Beach,Florida 32233 REVISION REQUEST /CORRECTIONS TO PLAN REVIEW COMMENTS Date //bpi Revision to Issued Permit Corrections to Comments Permit# R65/Y-035Y- Project Address 535 4-72-4'v77L A' cfal Civ,..):,- 7- Contractor/Contact Name 411-1-7—7 1-c°-v�e e-- 6( Phone 1 o K-5/3 - / 7 z_Y Email C Lo/JA., 4 c meta fs-,a,l Description of Proposed Revision/Corrections: Permit Fee Due$ Le'7-r`W a<N o wL�0 /7 'C�hs.�j-e, *3¶C ur FBC zo l 7 T1�a.-o%•7 / - a /'terra`/c s Additional Increase in Building Value$ 2R. Additional S.F. By signing below,I Wr,9-Y73e� (. / ,t<..14 affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved 7 Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: � uilding P anning &Zoning evie y Tree Administrator ••. is ‘TorT111.- //4 Pu. is Utilities Public Safety Dat Fire Services REVOCABLE ENCROACHMENT AGREEMENT 441 REVOCABLE ENCROACHMENT AGREEMENT by the City of Atlantic Beach, Florida,a municipal corporation organized and existingunder the laws of the State of Florida, hereinafter referred to as"CITY"and ��nv✓1�S °, mi Rot c k! of Atlantic Beach, Florida, hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach. This work is generally described as BY/Ick /?&. - pt-iv�w,L 4-p/`a� Any facility maintained, repaired, erected, and/or installed in the exrcise of the privilege granted remains subject to relocation or removal on thirty (30) days' notice by CITY to USER, said notice to USER shall be given by certified mail, return receipt requested, to the following address .S33_ r,'tic_ • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described easement or property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing,operating,replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code and all other land use and code requirements of the CITY, including City Code Section I9-7(h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department, for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of easements, public right- of-ways and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein tinder the terms of this permit and that all of said liabilities are ereby assu d by the USER. [)ate 10194( V Q Property Owner/Agent(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this 9S-4). day of 00-0 .4 , 20 I C. , • by Tenn t vd , who personally appeared before me and (printed name of Signer) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. u;Yoy MELISSAD.PINEDA � if • Commission#FF 967329 r-Expires March 2,2020 Signature of Notary Public, State ofFTorid . Bonded ThruTroy Fain Insurance 800-385.7019 Impartment Approval: Personally Known /,, �/ Produced Identification(Type) i i per_ v{.lVf.F--/ - Scott WI Hams, Pu lic 'for s irecte'r O:\Public Works\ADMIN\Revocable Encroachment Agreement.docx Revision Date:8/31/18 , ; , z / S � . ,:?,,,,,„ . ),,_.,,, B iY dingPeit Appiic #W Crr City of Atlantic Beach Building Department Updated 1U/9/18 INFORMATIONt....• 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY J 'r Phone: (904) 247-5826 Fax: (904) 247-5845 Email: Building-Dept@coab.us IS REQUIRED. •Job Address: 533 Atlantic Beach Court Permit Number: Re..5t bp- 0354- Legal Description Lot#25 Atlantic Beach Country Club Unit#2 RE# 169505-1420 Valuation of Work (Replacement Cost) $ 1,168,000.00 Heated/Cooled SF 4,083 Non- Heated/Cooled 2,291 • Class of Work: itiNew ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): Commercial 7Residential • If an existing structure, is a fire sprinkler system installed?: nYes ❑✓ No • Will tree(s)be removed in association with proposed project? Yes(must submit separate Tree Removal Permit) ao Describe in detail the type of work to be performed: Construction of new single family home Florida Product Approval#See attached for multiple products use product approval form Property Owner Information Name James and Tami Roick Address 2228 Ocean Walk Drive West City Atlantic Beach State FL Zip 32233 _Phone (904) 923-2379 E-Mail taroick@icloud.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) n/a Contractor Information Name of Company Claddagh Constructors, Inc. Qualifying Agent Matthew Fennell Address 3997 America Avenue City Jacksonville Beach State FL zip 32250 Office Phone (904) 241-1012 Job Site Contact Number (904) 813-1728 State Certification/Registration # CBC 058367 E-Mail claddaghmatt@gmail.com Architect Name& Phone# Fisher and Simmons Architects, Inc. 904-247-1800 Engineer's Name& Phone# Christopher C. Kathe, Inc. 808-217-4707 Workers Compensation Insurer OR Exempt t Expiration Date 04/05/2020 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING Y UR NOTICE OF COMMENCEMENT. ' ---1o mom 4.0'' /�/� (Signature of Wit) c.-1-:77"&1•.)tc' /' II (Signature of mer) UwsY` Signed and sworn to (or affirmed) befo - me thi I \Q day of Signed and sworn to(or affirm before me this, 110 day of Oc)10l2e.� _1 .. Vi 0. QG-�o�e,'_,�.0 I_$, �-% I 'QO Vii . =' - � D n ( - ` ,o •r v_-daLiiiig at i i te.444 nt, r ��P DANIELLEWILLIS ` o1N'vP!i'' DANIELLE WILLIS ( ''R � ` i* mac' Notary Public-State of Florida , i''°,7\.,1,---1,,� Notary Public-State of Florida rsonally Known OR -,- ,y fiW Commission#GG080201 ., •ersonally Known OR , s: . Iv Commission;GG 080201 Produced "::,,�o�it t•` My Comm.Expires Mar 6,2021 .,4,t. �cp?= My Comm.Expires Mar 6,2021 ` - [ ] Identification [ 'roduced Identification Bonded through Nation al Notary Assn. Identification '"" Bonded through National Notary Assn.T, o -,f iao..+ifir-14i.,r• • d PERMITTED BUILDING DATA DO NOT WRITE BELOW - OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft') yo 83 Non-Habitable Space (ft2) 3-2- 9/ LAND INFORMATION: Zoning District d kC-- Flood Zone X Minimum FFE 7/, (� BUILDING INFORMATION: Construction Type V Occupancy Group S ,ns)i -F of rn .41I Number of Stories 2. Max Occupancy Load Fire Sprinklers Required CONDITIONS/ COMMENTS: Rev. 2.7.2018 ATLANTIC BEACH COUNTRY CLUB OWNERS ASSOCIATION, INC. 414 Old Hard Road, Suite 502 Fleming Island, Florida 32003 Office 904-264-6553 Facsimile 904 269-272 October 2, 2018 Mr. Matt Fennell Claddagh Constructors, Inc. 3997 America Avenue Jacksonville Beach, FL 32250 RE: Architectural Submittal for Lot 25, Atlantic Beach Country Club Dear Mr. Fennell, The Architectural Review Board has reviewed your revised architectural and landscape plans for the above referenced property and finds them to be compliant with the requested modifications. Construction is hereby authorized. Please refer to the Atlantic Beach Country Club Architectural Guidelines for additional requirements for construction times and authorized signage. Both documents may be accessed on the web at www.atlanticbeachcountryclub.com. If you have questions or need additional information, please do not hesitate to give me a call. Thank you, Sincerely, Susan Wood President Enclosures Ss-a./.e O -P F'lorsolq FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Roick Residence Builder Name: Claddagh Constructors, Inc. Street: 533 Atlantic Beach Court Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number Owner: Jim and Tami Roick Jurisdiction. 261100 Design Location: FL,MAYPORT_NS County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (4189.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3992.10 ft2 b.Frame-Wood,Adjacent R=19.0 196.95 ft2 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 5 d.N/A R= ft' 5. Is this a worst case? 10.Ceiling Types (3358.0 sqf. Insulation Area No a.Roof Deck(Unvented) R=19.0 3358.00 ft' 6. Conditioned floor area above grade(ft2) 4083 b.N/A R= ft2 R= ' Conditioned floor area below grade(ft2) 0 11. .N/A Ducts R f ft' 7. Windows(680.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 315.12 a. U-Factor: Dbl,U=0.27 680.51 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 145.47 SHGC: SHGC=0.19 c.Sup:Attic,Ret:Attic,AH:Guest Suite 6 70.2 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 40.0 SEER:14.50 b.Central Unit 22.0 SEER:14.50 c. U-Factor: N/A ft' c.Central Unit 11,5 SEER:16.00 SHGC: 13.Heating systems kBtu/hr Efficiency , d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: b.Electric Heat Pump 21.6 HSPF:8.20 Area Weighted Average Overhang Depth: 6.320 ft. c.Electric Heat Pump 13.6 HSPF:10.00 Area Weighted Average SHGC: 0.190 14.Hot water systems 8. Floor Types (4083.0 sqft.) Insulation Area a.Natural Gas Tankless Cap:1 gallons EF:0.750 a.Slab-On-Grade Edge Insulation R=0.0 2424.00 ft' b. Conservation features b.Floor Over Other Space R=0.0 1119.00 ft2 None c.other(see details) R= 540.00 ft2 15.Credits Pstat Glass/Floor Area: 0.167 Total Proposed Modified Loads: 102.99 PASS Total Baseline Loads: 111.49 v-jy,00: I hereby certify that the planspand specifications coveredbyReviewpof the plans and iypTr1E Sr9�`©�, this calculation are in compliance with the Florida Energyspecifications covered bythis a T; Code. 2 calculation indicates compliance °co/7 ;',1,;. =s�'„'• .r;.:. N Ryan B. Ellis h ' „' `;; . � .. ? with the Florida Energy Code, rrr,, r,•,,;,.,• ,,r;.:Ti. •, _ PREPARED BY: _-__._ -_-_-.-___ _ Before construction is completed u - l- -i y DATE: 6n3ne this buildingwill be inspected for ,., a • compliance with Section 553.908 *`' ted ;; a I hereby certify that this building, as designed, is in compliance Florida Statutes. tt NA,' �'�•' with the Florida EnergyCode. C ''' _ �,, OD WEISL ,�. OWNER/AGENT: BUILDING OFFICIAL: Al DATE: - _._ -- DATE: TO -70-:-/-k----- - -/- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/13/2018 10:18 PM EnergyGaugee USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 , y OFFICE COP Y FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Roick Residence Builder Name Claddagh Constructors, Inc. Street: 533 Atlantic Beach Court Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number Owner: Jim and Tami Roick Jurisdiction. 261100 Design Location: FL,MAYPORT_NS County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (4169.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3992.10 ft2 b.Frame-Wood,Adjacent R=19.0 196.95 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types (3358.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=19.0 3358.00 ft2 6. Conditioned floor area above grade(ft2) 4083 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft' 7. Windows(680.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 315.12 a. U-Factor: Dbl,U=0.27 680.51 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 145.47 SHGC: SHGC=0.19 c.Sup:Attic,Ret:Attic,AH:Guest Suite 6 70.2 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 40.0 SEER:14.50 c. U-Factor: N/A ft' b.Central Unit 22.0 SEER:14.50 c Central Unit 11.5 SEER:16.00 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: b.Electric Heat Pump 21.6 HSPF:8.20 Area Weighted Average Overhang Depth: 6.320 ft. c.Electric Heat Pump 13.6 HSPF:10.00 Area Weighted Average SHGC: 0.190 14.Hot water systems 8. Floor Types (4083.0 sqft.) Insulation Area a.Natural Gas Tankless Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2424.00 ft2 EF:0.750 b. Conservation features b.Floor Over Other Space R=0.0 1119.00 ft2 None c.other(see details) R= 540.00 ft2 15.Credits Pstat Glass/Floor Area: 0.167 Total Proposed Modified Loads: 102.99 PASS Total Baseline Loads: 111.49 .ane. I hereby certify that the plans and specifications covered by Review of the plans and {,.+�� THE 3Tq;� + this calculation are in compliance with the Florida Energy specifications covered by this •, 'p Code. calculation indicates compliance , ''%„'= `�'o';�' l., Ryan B. Ellis �_; - i a. 's ' withthe Florida Energy Code. ; ti:�nrr,r: •:'....i:_.:.'2.,.;•` „ O s PREPARED BY: ___ _. Before construction is completed c 1; - s DATE: ___ 6/13/18 this building will be inspected for ;a compliance with Section 553.908 1 ,'PA . f .•.; t I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. �, O �15�,,�*'�• +�, 0L WET• 00 l � - - •'N• OWNER/AGENT: �� �j "'""""�� BUILDING OFFICIAL: _�tro,_,--- DATE: 64 � DATE:- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: Roick Residence Bu loer Name Street: 533 Atlantic Beach Court Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach , FL, Permit Number Design Location: FL,MAYPORT_NS Jurisdiction: 261100 Cond.Floor Area:: 4083 sq.ft. Cond.Volume 42026 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R. Single or Multi Point Test Data Required ACH(50)from HOUSE PRESSURE FLOW: FORM R405-2017 : 1 Pa cfm 2 Pa cfm Tested ACH(50) * : 3 Pa cfm — *Tested leakage must be less than or equal to the 4 Pa cfm required ACH(50)shown on Form R405-2017 for 5 Pa cfm this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation 6 Pa - cfm system. R402.4.1.2 Testi ng.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures: 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,If Installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Testing shall be conducted by either VIES • 44 performance results demonstrate compliance individuals as defined in Section r ti p with Florida Energy Code requirements in 553.993(5)or(7), Florida Statutes or accordance with Section R402.4.1.2. individuals licensed as set forth in `:_ ;..• 0 . Section 489.105(3)(f), u� approved third party.A written report 11° of the results of the test shall be signed ; * � SIGNATURE: by the third party conducting the test C and provided to the code official. �' Cp W '� � �°� PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2017 PROJECT Title: Roick Residence Bedrooms: 5 Address Type. Street Address Building Type: User Conditioned Area: 4083 Lot# Owner Name: Total Stories: 2 Block/Subdivision; #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angie: 0 Street: 533 Atlantic Beach Court Permit Office: Atlantic Beach cross Ventilation: county: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5°/a 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT_NS FL MAYPORT_NS 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume 1 Blockl 2424 24482.4 2 Block2 1119 12197.1 3 Block3 540 5346 SPACES Number Name Area Volume Kitchen Occupants Bedrooms 'Mil ID Finished Cooled Heated 1 1st Floor 2424 24482.4 Yes 3 2 1 Yes Yes Yes 2 2nd Floor 1119 12197.1 No 2 2 1 Yes Yes Yes 3 Guest Suite 540 5346 No 1 1 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet - 1 Slab-On-Grade Edge Insulation 1st Floor 231.4 ft 0 2424 ft2 ____ 0 0 1 2 Floor Over Other Space 2nd Floor ____ ____ 1119 ft' 0 0 0 1 3 Floor over Garage Guest Suite ____ ____ 540 ft' 13 0 0 1 ROOF Roof Gable Roof Solar SA Ernitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 3858 ft2 1234 ft' Medium 0.6 No 0.3 No 19 39.8 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 2964 ft2 N N 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING V4 Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) 1st Floor 0 Blown 1699 ft' 0.11 Wood 2 Under Attic(Unvented) 2nd Floor 0 Blown 1119 ft' 0.11 Wood 3 Under Attic(Unvented) Guest Suite 0 Blown 540 ft2 0.11 Wood WALLS Adjacent Cavity Matt) sheathing Framing Solar Below __ f} nmt__ In W._._Wall_Sype_____ Space R-Value Ft In Ft In Area. R-Value _Fraction. . Absor-.__Grade% 1 S Exterior Frame-Wood 1st Floor 19 38 10.1 383.8 ft` 0.05 0.170000 0 2 S Exterior Frame-Wood 1st Floor 19 11.7 10.1 118.2 ft2 0.05 0.170000 0 3 S Garage Frame-Wood 1st Floor 19 19.5 10.1 197.0 ft2 0.05 0.170000 0 4 E Exterior Frame-Wood 1st Floor 19 46.7 10.1 471.7 ft2 0.05 0.170000 0 5 N Exterior Frame-Wood 1st Floor 19 10 10.1 101.0 ft2 0.05 0.170000 0 6 N Exterior Frame-Wood 1st Floor 19 59.1 10.1 596.9 ft2 0.05 0.170000 0 7 W Exterior Frame-Wood 1st Floor 19 46 1 10 1 465.6 ft' 0 05 0.170000 0 8 S Exterior Frame-Wood 2nd Floor 19 6 10.9 65.4 ft' 0.05 0.170000 0 9 E Exterior Frame-Wood 2nd Floor 19 23.6 0 10.9 257.2 ft2 0.05 0.170000 0 10 N Exterior Frame-Wood 2nd Floor 19 40.7 10.9 443.6 ft2 0.05 0.170000 0 11 W Exterior Frame-Wood 2nd Floor 19 23.4 10.9 255.1 ft2 0.05 0.170000 0 12 S Exterior Frame-Wood Guest Suite 19 18.5 9.9 183.1 ft2 0.05 0.170000 0 13 E Exterior Frame-Wood Guest Suite 19 17.7 9.9 175.2 ft2 0.05 0.170000 0 14 N Exterior Frame-Wood Guest Suite 19 19.3 9.9 191.1 ft' 0.05 0.170000 0 15 W Exterior Frame-Wood Guest Suite 19 28.7 9.9 284.1 ft' 0.05 0.170000 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.27 0.19 N 21.6 ft' 2 ft 0 in 1 ft 0 in None None 2 S 1 Vinyl Low-E Double Yes 0.27 0.19 N 35.3 ft' 2 ft 0 in 1 ft 0 In None None 3 S 2 Vinyl Low-E Double Yes 0.27 0.19 N 28.0 ft' 8 ft 0 in 1 ft 0 in None None 4 S 2 Vinyl Low-E Double Yes 0.27 0.19 N 32.0 ft' 8 ft 0 in 1 ft 0 in None None 5 E 4 Vinyl Low-E Double Yes 0.27 0.19 N 8.0 ft2 2 ft 0 in 1 ft 0 in None None 6 N 5 Vinyl Low-E Double Yes 0.27 0.19 N 10.0 ft2 2 ft 0 in 1 ft 0 in None None 7 E 4 Vinyl Low-E Double Yes 0.27 0.19 N 30.0 ft' 2 ft 0 in 1 ft 0 in None None 8 N 6 Vinyl Low-E Double Yes 0.27 0.19 N 72.0 ft' 12 ft 0 in 1 ft 0 in None None 9 N 6 Vinyl Low-E Double Yes 0.27 0.19 N 160.0 ft2 12 ft 0 in 1 ft 0 in None None 10 N 6 Vinyl Low-E Double Yes 0.27 0.19 N 25.4 ft2 12 ft 0 in 1 ft 0 in None None 11 W 7 Vinyl Low-E Double Yes 0.27 0.19 N 50.8 ft' 2 ft 0 in 1 ft 0 in None None 12 S 8 Vinyl Low-E Double Yes 0.27 0.19 N 10.0 ft' 2 ft 0 in 1 ft 0 in None None 13 E 9 Vinyl Low-E Double Yes 0.27 0.19 N 7.0 ft2 2 ft 0 in 6.9 ft 0 in None None 14 E 9 Vinyl Low-E Double Yes 0.27 0.19 N 4.0 ft' 2 ft 0 in 1 ft 0 in None None 15 N 10 Vinyl Low-E Double Yes 0.27 0.19 N 56.4 ft' 2 ft 0 in 1 ft 0 in None None 16 N 10 Vinyl Low-E Double Yes 0.27 0.19 N 43.2 ft2 2 ft 0 in 1 ft 0 in None None 17 W 11 Vinyl Low-E Double Yes 0.27 0.19 N 4.0 ft' 2 ft 0 in 6.9 ft 0 in None None 18 W 11 Vinyl Low-E Double Yes 0.27 0.19 N 7.0 ft2 2 ft 0 in 1 ft 0 in None None 6/13/2018 10:18 PM EnergyGaugei USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame _ Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 19 S 12 Vinyl Low-E Double Yes 0.27 0.19 N 8.1 ft' 2 ft 0 in 1 ft 0 in None None 20 E 13 Vinyl Low-E Double Yes 0.27 0.19 N 18.4 ft, 2 ft 0 in 4.7 ft 0 in None None 21 E 13 Vinyl Low-E Double Yes 0.27 0.19 N 17.0 ft' 2 ft 4 In 4.7 ft 0 In None None 22 N 14 Vinyl Low-E Double Yes 0.27 0.19 N 14.0 ft' 2 ft 0 in 4.7 ft 0 in None None 23 W 15 Vinyl Low-E Double Yes 0.27 0.19 N 18.4 ft' 2 ft 0 in 6.5 ft 0 in None None GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 1544 ft' 1544 ft' 212.1 ft 10 1 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000458 4903 269.17 506.21 .434 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.2 41 kBtu/hr 1 sys#1 2 Electric Heat Pump/ None HSPF:8.2 21.6 kBtu/hr 2 sys#2 3 Electric Heat Pump/ None HSPF.10 13 6 kBtu/hr 3 sys#3 COOLING SYSTEM _V - 4 System Type Subtype _. Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 14.5 40 kBtu/hr 1200 cfm 0.75 1 sys#1 2 Central Unit/ None SEER: 14.5 22 kBtu/hr 660 cfm 0.75 2 sys#2 3 Central Unit/ None SEER: 16 11.5 kBtu/hr 345 cfm 0.75 3 sys#3 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.75 1 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM I FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS ----Supply---- —Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 315.12 f Attic 121.2 ft' Default Leakage Garage (Default)c(Default)c 1 1 2 Attic 6 145.47 f Attic 55.95 fl' Default Leakage Attic (Default)c(Default)c 2 2 3 Attic 6 70.2 11 Attic 27 ft' Default Leakage Guest Suite (Default)c(Default)c 3 3 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling JanFelx1Jan H b Marr A rr Ma X Jun Jull X Au X Se Octt Novv Dec Venting c H tinX Jan Feb X Mar X�Apr May Jun Jul Aug Sep X]Oct fXI Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index, the more efficient the home. 533 Atlantic Beach Court, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9 Nall Tapes Insulation Area 2. Single family or multiple family Single-family a. Frame Wood,Exterior R=19.0 3992.10 ft2 b.Frame-Wood,Adjacent R=19.0 196.95 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a Roof Deck(Unvented) R=19.0 3358.00 ft2 6. Conditioned floor area(ft') 4083 b.N/A R= ft2 7. Windows"' Description Area c.N/A R= ft2 a. U-Factor: Dbl.U=0.27 680.51 ft2 11 Ducts R ft' a Sup Attic. Ret:Attic.AH: Garage 6 315.12 SHGC: SHGC=0.19 o.Sup: Attic,Ret:Attic,AH:Attic 6 145.47 b. U-Factor: N/A ft2 c.Sup:Attic,Ret:Attic,AH:Guest Suite 6 70.2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 40.0 SEER:14.50 SHGC: b.Central Unit 22.0 SEER:14.50 d. U-Factor: N/A ft' c.Central Unit 11.5 SEER:16.00 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 41.0 HSPF:8.20 Area Weighted Average Overhang Depth: 6.320 ft. b Electric Heat Pump 21.6 HSPF:8.20 Area Weighted Average SHGC: 0.190 c. Electric Heat Pump 13.6 HSPF:10.00 8. Floor Types Insulation Area 14 Hot wafer systems a.Natural Gas Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2424.00 ft' EF:0.75 b.Floor Over Other Space R=0.0 1119.00 ft2 c.other(see details) R= 540.00 ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ..,,,,,-0,1,77,:c..7.2„-..7,„l. , : 11>tis ra ' •. Construction through the above energy saving features which will be installed (or exceeded) �OCt _ iCo in this home before final inspection. Otherwise, a new EPL Display Card will be completed ywQ,,,°�,' _= �:n based on installed Code compliant features. tom, •;,, ' ''N•"'s „�o Builder Signature: 7// Date: G7e.0 F 0 ._.) m es Address of New Home: 533 Atlantic Beach Court City/FL Zip: Atlantic Beach, FL / - �,"�++` coll� ��\ 32233 ~:,D wT,.'.,. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/13/2018 10:18 PM EnergyGauge0 USA-FIaRes201/ -Section R405 4.1 Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 533 Atlantic Beach Court Permit Number: Atlantic Beach ,FL, MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401,3 Energy Performance Level(EPL)display card(MandatoryThe building official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law(Section 553.9085, Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 InstallationThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. 6. Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace. Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air IeakagANindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or HAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Compliant Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances.In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings snail meet not lees than the basement wall R-value reouirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated whore it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.6 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that, except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed In accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufactun handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing Is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatoryl)♦eated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.6.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping In accordance with the times when heated water is used in the occupancy. 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 -FBG 6th Edition(2017)Compliant Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/:inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F(38°C to 80°C). R403.6.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code:Energy Conservation,Commercial Provisions,for the type of equipment installed.Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.6.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be Installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including: Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacyWhen installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air Is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUM (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2 8 cfm/watt Any For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Compliant Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity or the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer.in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory)Snow-and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy, such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Compliant Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(ManaatOrrgie energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(MandatoryFuel gas lighting systems shall not have continuously burning pilot lights. 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 •FBC 6th Edition(2017) Compliant Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Roick Residence Builder Name: Street: 533 Atlantic Beach Court Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction; 261100 Design Location: FL.MAYPORT_NS COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealedbe insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation,insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by Insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer.Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 6/13/2018 10:18 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 414- Manual S Compliance Report Job: wrightsoft` Date: 5129118 1st Floor By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd.Jacksonville.FL 32223 Phone:904.268.3670 Fax 904.268-3670 Email.eos jaxeprnail corn Project Information For: Roick Residence 533 Atlantic Beach Court, Atlantic Beach, FL Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 31656 Btuh Entering coil DB: 75.0°F Outdoor design WB: 77.4°F Latent gain: 3602 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 35258 Btuh Indoor RH: 50% Estimated airflow: 1333 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Bryant Model: 214DNA0420000A0+FV4CNF005L Actual airflow: 1333 cfm Sensible capacity: 31600 Btuh 100% of load Latent capacity: 8400 Btuh 233% of load Total capacity: 40000 Btuh 113% of load SHR: 79% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 23827 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data atActual Design Conditions Equipment type: Split ASHP Manufacturer: Bryant Model: 214DNA0420000A0+FV4CNF005L Actual airflow: 1333 cfm Output capacity: 41000 Btuh 172% of load Capacity balance: 24 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model. Actual airflow: 1333 cfm Output capacity: 7.0 kW 100% of load Temp. rise: 50 °F Meets are all requirements of AC CA Manual S. +r- wrightsoft2018-Jun-13 22 19 22 �� 9 Right-Suite®universal 2017 1?C t7 RStn d5i Page 1 ...esidence,533 Atlantic Beach Court,All Bch.rJp Calc = MJn ion! Door laces o Manual S Com liance Re ort °b wrightsoft p p Date: 5129!18 2nd Floor By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd.Jacksonville.FL 32223 Phone:904-268-3670 Fax:904-268-3670 [mall:eds.tax@gmail.com Project Information For: Roick Residence 533 Atlantic Beach Court, Atlantic Beach. FL Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 17722 Btuh Entering coil DB: 75.0°F Outdoor design WB: 77.4°F Latent gain: 1875 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 19597 Btuh Indoor RH: 50% Estimated airflow: 733 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Bryant Model: 214DNA0240000A0+FV4CNF002L Actual airflow: 733 cfm Sensible capacity: 17600 Btuh 99% of load Latent capacity: 4400 Btuh 235% of load Total capacity: 22000 Btuh 112% of load SHR: 80% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 9689 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Bryant Model: 214DNA0240000A0+FV4CNF002L Actual airflow: 733 cfm Output capacity: 21600 Btuh 223% of load Capacity balance: 17 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 733 cfm Output capacity: 2.2 kW 79% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. 2016-Jun-13 22.19:22 wrightsoft Right-suite®Universal 2017 17.0.17 RSU17457 Page 2 ...esidence,533 Atlantic Beach Court,Atl Bch.roe Calc = MJB Front Door faces 5 wrightsoft° Manual S Compliance Report Dabe: 5129118 Guest Suite By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd.Jacksonville. FL 32223 Phone 904.268-3670 Fax 904-268-3670 Email ouc)2x(d3omau corn Project Information For: Roick Residence 533 Atlantic Beach Court, Atlantic Beach, FL Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 8686 Btuh Entering coil DB: 76.5°F Outdoor design WB: 77.4°F Latent gain: 1666 Btuh Entering coil VVB: 63.3°F Indoor design DB: 75.0°F Total gain: 10352 Btuh Indoor RH: 50% Estimated airflow: 400 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Mitstubishi Electric Model: SEZ-KD12NA+SUZ-KAl2NA Actual airflow: 400 cfm Sensible capacity: 9085 Btuh 105%of load Latent capacity: 2415 Btuh 145% of load Total capacity: 11500 Btuh 111% of load SHR: 79% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 7029 Btuh Entering coil DB: 67.5°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Mitstubishi Electri Model: SEZ-KD12NA+SUZ-KAl2NA Actual airflow: 400 cfm Output capacity: 13600 Btuh 193% of load Capacity balance: 19 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 400 cfm Output capacity: 1.7 kW 83°%o of load Temp. rise: 50 °F Meets are all requirements of AC CA Manual S. WI- htsoft` 2018-Jun-13 22 19:22 g Right-Suite®Universal 2017 17.0.17 RSU17457 Page 3 A+c\ ...esidence,533 Atlantic Beach Court,Atl Bch.rup Calc°MJ8 Front Door faces: S Pj roect SummaryJob: wrightsoft 1Date. 6/29118 1 s Floor By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville,FL 32223 Phone:904-268-3670 Fax:904-268-3670 Erroll:ed5.jax(dJpmall.corn Pro ect Informa.'+n For: Roick Residence 533 Atlantic Beach Court, Atlantic Beach, FL Notes: Desk n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F Outside db 94 °F Inside db 68 °F Inside db 75 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 % Moisture difference 50 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23827 Btuh Structure 31656 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23827 Btuh Use manufacturer's data Rate/swing multiplier 1.00y Infiltration Equipment sensible load 31656 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 3602 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2424 2424 Equipment latent load 3602 Btuh Volume(ft3) 24482 24482 Air changes/hour 0.30 0.14 Equipment total load 35258 Btuh Equiv.AVF (cfm) 120 59 Req. total capacity at 0.75 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade BRYANT HEATING AND COOLING SYS... Trade BRYANT HEATING AND COOLING SYS... Model 214DNA0420000A0 Cond 214DNA0420000A0 AHRI ref 9667310 Coil FV4CNF005L AHRI ref 9667310 Efficiency 8.2 HSPF Efficiency 12.0 EER, 14.5 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 12000 Btuh Temperature rise 28 °F Total cooling 40000 Btuh Actual air flow 1333 cfm Actual air flow 1333 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point = 24 °F Backup: Input = 7 kW, Output= 23827 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htSO1fY" 2018-Jun-13 22.19:22 .� 9 Right-Suiten Universal 2017 17.0.17 RSU17457 Page 1 ..esidence,533 Atlantic Beach Court,Atl Bch.rup Calc =MJ8 Front Door faces: S • 4i wrightsoft` Project Summary Date: 5/29/18 2nd Floor By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville,FL 32223 Phone: 904.269-3670 Fax 904-268-3670 Email:eds.lax@gmail.com Project Information For: Roick Residence 533 Atlantic Beach Court, Atlantic Beach, FL Notes: Desi• n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F Outside db 94 °F Inside db 68 °F Inside db 75 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 9689 Btuh Structure 17722 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 9689 Btuh Use manufacturer's data Rate/swing multiplier 1.00y Infiltration Equipment sensible load 17722 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1875 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1119 1119 Equipment latent load 1875 Btuh Volume(ft') 12197 12197 Air changes/hour 0.26 0.13 Equipment total load 19597 Btuh Equiv.AVF (cfm) 53 26 Req. total capacity at 0.75 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade BRYANT HEATING AND COOLING SYS... Trade BRYANT HEATING AND COOLING SYS... Model 214DNA0240000A0 Cond 214DNA0240000A0 AHRI ref 9676151 Coil FV4CNFOO2L AHRI ref 9676151 Efficiency 8.2 HSPF Efficiency 12.0 EER, 14.5 SEER Heating input Sensible cooling 15400 Btuh Heating output 21600 Btuh @ 47°F Latent cooling 6600 Btuh Temperature rise 27 °F Total cooling 22000 Btuh Actual air flow 733 cfm Actual air flow 733 cfm Air flow factor 0.076 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point = 17 °F Backup: Input = 2 kW, Output = 7616 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wri htSOft 2019-Jun-13 22 19:22 !.,„ g Right-SuiterEl Universal 2017 17 0 17 RSU17457 Page 2 Ar:C-A ...esidence, 533 Atlantic Beach Court,Atl Bch rup Calc = MJ8 Front Door faces S 4 wrightsoft Project Summary Dabe; 5129!18 Guest Suite By: M.Ellis Energy Design Systems, Inc. 11727 Braay Ra,Jacksonville,FL 32223 Phone:904-268-3570 Fax:904.268-3070 Email:eos lazogmaII corn Project Information For: Roick Residence 533 Atlantic Beach Court, Atlantic Beach, FL Notes: Desi• n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F Outside db 94 °F Inside db 68 °F Inside db 75 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 5848 Btuh Structure 6956 Btuh Ducts 1181 Btuh Ducts 1729 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 7029 Btuh Use manufacturers data Rate/swing multiplier 1.00y Infiltration Equipment sensible load 8686 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1314 Btuh Ducts 352 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 540 540 Equipment latent load 1666 Btuh Volume(ft3) 5346 5346 Air changes/hour 0.48 0.23 Equipment total load 10352 Btuh Equiv.AVF (cfm) 43 21 Req. total capacity at 0.70 SHR 1.0 ton Heating Equipment Summary Cooling Equipment Summary Make Mitstubishi Electric Make Mitstubishi Electric Trade Mini-Splits Trade Mini-Splits Model SEZ-KD12NA Cond SEZ-KD12NA AHRI ref 2017543525 Coil SUZ-KAl2NA AHRI ref 2017543525 Efficiency 10 HSPF Efficiency 12.8 EER, 16 SEER Heating input Sensible cooling 8050 Btuh Heating output 13600 Btuh @ 47°F Latent cooling 3450 Btuh Temperature rise 31 °F Total cooling 11500 Btuh Actual air flow 400 cfm Actual air flow 400 cfm Air flow factor 0.057 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point = 19 °F Backup: Input = 2 kW, Output = 5848 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri ht f+ 2018-Jun-13 22:19:22 g Right-Suite®Universal 2017 17.0.17 RSU17457 Page 3 esioence, 533 Atlantic Beach Court,Atl Bch.rup Calc= MJ8 Front Door faces: S Ali N 1st Floor Laundry Pantry 0 87 cfm le 70 cfm 0 u rti.n i •' 14 " 4.. 4 .. 14 " et Rise t • c +� 88 cfm 42 1400 c 6" • • Kitchen 4" Powde (�� '8 cfm 10" 6" 88 cfm 8., Foyer ` '�'6�„96 cfm Dining 1-' 95 cfm 6 I 12 x 12 '12x12 WIC1 1040cfm e !8 cfm 6" 4" I Living Study 7„ 6„ et I" c m 40 cfm f 12x 2 4" 12" ;7" ""12x 2 Ff 4 6„ 8„ —' °. . MI 106 dm 4 ■" I. -rser 7 WICA 6 °° 4 84 fm 4" Master 4 " 114 6 cfm 4„ — Master Bath 126 cfm WIC B 611.63 cfm Job #: Exclusively for the use of: Scale: 1 : 94 Performed for: Page 1 Roick Residence Cooler Bear Heat&Air LLC Right-Suitee Universal 2017 533 Atlantic Beach Court 17.0.17 RSU17457 Atlantic Beach,FL 2018-Jun-13 22:19:13 .tlantic Beach Court,Atl Bch.rup 4 N 2nd Floor I Guest Closet (�� r400 cfm 48 cfm 10" Guest Bath 1 Wise- 14" 4• �• �' 141 cfm 1$,,:: , ..�'„- %l• '60 cf e7 Guest Ste Ret Rise/01 Guest Ste Ba p'• : st�11 + 6„ Stairs e,•.,., cHest 1 10" 0 141 cfm e .., �.0. cfm 1 i ' 'a 253 cfm 111 . " 8,oat 2 98 cfm liirlijailiptil18 ' 245 cfm C . -8 . Sic-age ,0, , Hest 2 r .... ... 161:14 - 1_; • ` , E4 53 cfm Guest Bath 2 16i ser 0 14 Job#: Exclusively for the use of: Scale: 1 : 94 Performed for: Page 2 Roick Residence Cooler Bear Heat&PH-LLC Right-Suitee Universal 2017 533 Atlantic Beach Court 17,0.17 RSU17457 Atlantic Beach, FL 2018-Jun-13 22:19:13 ...tlantic Beach Court,Atl Bch.rup Duct System Summary Job: wrightsoft Date: 1st Floor By: Exclusively for the use oto Cooler Bear Heat&Air LLG Project Information For: Rolck Residence 533 Atlantic Beach Court, Atlantic Beach, FL Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/return available pressure 0.071 / 0,029 in H2O 0.071 / 0.029 in H2O Lowest friction rate 0.028 in/100ft 0.028 in/100ft Actual air flow 1400 cfm 1400 cfm Total effective length (TEL) 363 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 1 h 85 4 2 0.033 4.0 Ox 0 VIFx 41.5 175.0 st17 Dining c 2371 95 96 0.030 6.0 Ox 0 VIFx 58.8 180.0 st12 Foyer h 2225 95 92 0.028 6.0 Ox 0 VIFx 72.0 187.0 st12 Hall 1 c 884 36 36 0.043 4.0 Ox 0 VIFx 47.8 120.0 st10 Kitchen c 2152 86 88 0.038 6.0 Ox 0 VIFx 49.7 140.0 st10 Kitchen-A c 2152 86 88 0.033 6.0 Ox 0 VIFx 54.8 160.0 st11 Laundry I c 2140 84 87 0.029 4.0 Ox 0 VIFx 63.0 180.0 st14 Living I c 978 40 40 0.037 6.0 Ox 0 VIFx 37.2 155.0 st17 Living-A I c 978 40 40 0.032 6.0 Ox 0 VIFx 42.9 180.0 st18 Master I c 2596 100 106 0.043 7.0 Ox 0 VIFx 31.7 135.0 st16 Master Bath c 1540 59 63 0.037 4.0 Ox 0 VIFx 36.4 155.0 st19 Master Bath-A c 1540 59 63 0.041 4.0 Ox 0 VIFx 39.9 135.0 st16 Master-A c 2596 100 106 0.040 7.0 Ox 0 VIFx 41.5 135.0 st16 Pantry c 1732 70 70 0.033 4.0 Ox 0 VIFx 57.8 160.0 st13 Powder c 1173 46 48 0.030 4.0 Ox 0 VIFx 60.1 180.0 st 14 Study c 2565 102 104 0.032 7,0 Ox 0 VIFx 47.4 175.0 st17 WIC 1 I h 2298 98 63 0.033 4.0 Ox 0 VIFx 42.8 175.0 st17 WIC A I c 2055 79 84 0.032 4.01 Ox 0 VIFx 44.9 175.0 st20 WIC B I c 3108 120 126 0.032 4.01 Ox 0 VIFx 49.0 175.0 st20 Bold/iralic values have been manually overridden wrightsoft' Right-Suite®Universal 2017 17.0.17 RSU17457 2018-Jun-13 22:19:10 ACCA Page 1 esidence,533 Atlantic Beach Court,All Bch rup Calc= MJ8 Front Door faces S Supply Trunk Detail Table Trunk litg Gig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st9 Peak AVF 599 604 0.028 565 14.0 0 x 0 ViniFix st2 st2 Peak AVF 599 604 0,025 565 14.0 0 x 0 ViniFix st3 Peak AVF 801 796 0.032 750 14.0 0 x 0 ViniFix st15 Peak AVF 801 796 0.032 750 14.0 0 x 0 ViniFix st3 st16 Peak AVF 801 796 0.032 750 14.0 0 x 0 ViniFix st15 st11 Peak AVF 276 275 0.028 506 10.0 0 x 0 VinlFlx st10 st12 Peak AVF 190 188 0.028 544 8.0 0 x 0 VinlFlx st11 st13 Peak AVF 200 205 0.029 1045 6.0 0 x 0 ViniFix st10 st14 Peak AVF 130 135 0.029 686 6.0 0 x 0 VinIFlx st13 st10 Peak AVF 599 604 0.028 565 14.0 0 x 0 ViniFix st9 st18 Peak AVF 40 40 0.032 203 6.0 0 x 0 ViniFix st17 st17 Peak AVF 282 249 0.032 359 12.0 0 x 0 ViniFix st16 st19 Peak AVF 259 273 0.032 781 8.0 0 x 0 VinIFIx st16 st20 Peak AVF 200 210 0.032 1069 6.0 0 x 0 ViniFix st19 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk th2 Ox 0 1400 1400 104.0 0.028 792 18.0 Ox 0 VIFx Bold/italic values have been manually overridden �. wri_htsoft- Right-Suitee Universal 2017 17.0 17 RSU17457 2018-Jun-13 22:19:10Page 2 ACOA ...esidence,533 Atlantic Beach Court,Atl Bch rup Calc = MA Fronl Dooi laces Duct S stem Summar Job: UP wrightsoft Y Y Date: 2nd Floor ,- Exclusively for the use of: Cooler Bear Heat&Alr LLC Project Information For: Roick Residence 533 Atlantic Beach Court, Atlantic Beach, FL Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/return available pressure 0.069/ 0.031 in H2O 0.069/ 0.031 in H2O Lowest friction rate 0.027 in/100ft 0.027 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 369 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Guest 1 c 2359 98 100 0.031 7.0 Ox 0 VIFx 36.2 190.0 st6 Guest 2 c 2359 98 100 0.071 7.0 Ox 0 VIFx 7.2 90.0 st1 Guest Bath 1 h 1886 88 85 0.027 4.0 Ox 0 VIFx 45.2 210.0 st7 Guest Bath 2 I h 2011 94 91 0.049 4.0 Ox 0 VIFx 12.2 130.0 st8 Lon c 2315 95 98 0.040 7.0 Ox 0 VIFx 22.2 150.0 st5 Lott-A c 2315 95 98 0.041 7.0 Ox 0 VIFx 18.2 150.0 st5 Stairs c 1418 60 60 0.034 4.0 Ox 0 VIFx 34.5 170.0 st5 Storage I c 1418 60 60 0.046 4.0 Ox 0 VIFx 20.2 130.0 st5 WIC 01 I h 1290 60 57 0.028 4.0 Ox 0 VIFx 41.2 210.0 st7 WIC G2 h 1136 53 50 0.050 4.0 Ox 0 VIFx 9.2 130.0 st8 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 555 559 0.027 523 14.0 0 x 0 VinIFIx st4 st1 Peak AVF 800 800 0.027 748 14.0 0 x 0 VinIFIx st4 Peak AVF 702 700 0.027 657 14.0 0 x 0 VinIFIx st1 st8 Peak AVF 146 141 0.049 746 6.0 0 x 0 VinlFlx st4 st6 Peak AVF 246 242 0.027 451 10.0 0 x 0 VinIFix st5 st7 Peak AVF 148 142 0.027 753 6.0 0 x 0 VinlFlx st6 Bold/italic values have been manually overridden 2015-Jun-13 22.19:10 -• wrightsofV Right-Suite®Universal 2017 17 0.17 RSU17457 Page 3 ...esidence,533 Atlantic Beach Court,Atl Bch.rup Calc= MJ8 Front Door faces: S Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diem H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 306 302 114.0 0.027 550 10.0 Ox 0 VIFx rt3 rb9 OX 0 250 256 108.0 0.029 470 10.0 Ox 0 VIFx rt3 rb10 Ox 0 245 241 73.0 0.042 448 10.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt3 Peak AVF 555 559 0.027 523 14.0 0 x 0 VinIFIx rt1 rt1 Peak AVF 800 800 0.027 748 14.0 0 x 0 VinlFlx Bold/italic values have been manually overridden 2018-Jun-13 22:19:10 wrightsoft• Right-Suite®Universal 2017 17.0 17 RSU17457 Page 4 ACCP. .esidence,533 Atlantic Beach Court,All Bch rup Calc = MJ8 Front Door faces S Duct System SummaryJob: wrightsoft y Date Guest By: Exclusively for the use of: Cooler Gear Heat&Air LLC Project Information For: Roick Residence 533 Atlantic Beach Court, Atlantic Beach, FL Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/return available pressure 0.069/ 0.031 in H2O 0.069/ 0.031 in H2O Lowest friction rate 0.087 in/100ft 0.087 in/100ft Actual air flow 400 cfm 400 cfm Total effective length (TEL) 115 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Guest Closet h 1234 48 47 0.091 4.0 Ox 0 VIFx 5.8 70.0 Guest ste C 3790 140 141 0.087 7.0 Ox 0 VIFx 9.4 70.0 Guest Ste Bath h 1850 71 71 0.094 4.0 Ox 0 VIFx 3.0 70.0 Guest Ste-A c 3790 140 141 0.091 7.0 Ox 0 VIFx 5.4 70.0 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat! Trunk rb8 Ox 0 400 400 35.8 0.087 733 10.0 Ox 0 VIFx Bold/italic values have been manuaNy overridden 2018-Jun-13 22:19:10 wrightsoft• Right-Suite®Universal 2017 17.0 17 RSU17457 Page 5 AC ..esidence,533 Atlantic Beach Court,Atl Bch.rup Calc = MJ8 Front Door faces S ESICC EVALUATION Most Widely Accepted and Trusted SERVICE Innovation ICC-ES Evaluation Report ESR-1361 ICC-ES I (800)423-6587 I (562) 699-0543 I www.icc-es.org Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 06 50 00—STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC. 1015 BRUNDIDGE BOULEVARD POST OFFICE BOX 589 TROY, ALABAMA 36081 EVALUATION SUBJECT: STRUCTURAL FIBERGLASS FIRE RATED COLUMNS: (HB&G PermaCast® Fire Rated, Dixie Pacific DuraCastTM Fire Rated, Crown ColumnTM Fire Rated, SpunCast Structural Fiberglass ColumnTM Fire Rated and Hartmann Sanders® Fire Rated) STRUCTURAL FIBERGLASS COLUMNS: (HB&G PermaCast®, Dixie Pacific DuraCastTM, Crown ColumnTM, SpunCast Structural Fiberglass ColumnTM and Hartmann Sanders®) ICC ICC - ICC PMG LISTED "2014 Recipient of Prestigious Western States Seismic Policy Council ass (WSSPC)Award in Excellence" A Subsidiary of CODECOUNCCIl' ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. ANSI There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this ACCREDRED ISO/ILC moss report, or as to any product covered by the report. Product Certification Body B1000 Copyright©2018 ICC Evaluation Service, LLC. All rights reserved. ESR-1361 I Most Widely Accepted and Trusted Page 3 of 3 TABLE 1-ALLOWABLE AXIAL LOADS(Ibs)1'2'3 STRUCTURAL FIBERGLASS COLUMNS AND STRUCTURAL FIBERGLASS FIRE RATED COLUMNS COLUMN TYPE WALL THICKNESS MAXIMUM MAXIMUM AND NOMINAL (in) LENGTH ALLOWABLE LOAD(lbs)4 SIZE(in) Bottom Top (ft-in) 6-Square 0.377 0.341 8-0 8700 6-Square 0.338 0.317 9-0 8925 6-Square 0.299 0.292 10.0 6100 8-Square 0.357 0.342 8-0 6725 8-Square 0.347 0.353 10-0 4275 8-Square 0.344 0.358 12-0 4500 10-Square 0.508 0.512 8-0 5300 10-Square 0.511 0.498 10-0 4325 10-Square 0.549 0.505 12-0 7300 12-Square 0.513 0.502 8-0 5875 12-Square 0.507 0.490 10-0 5525 12-Square 0.512 0.470 12-0 6325 8-Round Tapered 0.335 0.310 8-0 3660 8-Round Tapered 0.351 0.364 9-0 5300 8-Round Tapered 0.298 0.365 10-0 4850 10-Round Tapered 0.309 0.278 8-0 3650 10-Round Tapered 0.294 0.427 10-0 4325 10-Round Tapered 0.464 0.205 12-0 6100 12-Round Tapered 0.352 0.363 8-0 5375 12-Round Tapered 0.291 0.386 10-0 3890 12-Round Tapered 0.410 0.422 12-0 5175 Table 1 Notes: 1SI Units conversion:1 in.=25.4 mm, 1 ft=0.3 m, 1 lbf=4.5 N. 2Round columns include plain and fluted. 'Square columns include plain,fluted and recessed panels. 'Maximum Allowable Loads are based on a worst-case eccentricity of 0.167 times the column width or diameter measured from the center line of the top of the column. rr Noom lull lull 111303. BUILDING PRODUCTS i LucaWN. IX1EED PACIFIC* ,..E0 IARTr1ANN SANDERS` SPUNCAST STRUCTURAL FIBERGLASS COLUMNTM SPUNCAST STRUCTURAL FIBERGLASS COLUMN TM FIRE RATED FIGURE 1-PRODUCT TRADEMARKS Renovations New Construction Claddagh Constructors, Inc. CB C058367 tel: (904) 241-1012 3997 America Ave fax: (904) 242-9344 Jacksonville Beach, Florida 32250 e-mail:mattcladdagh@yahoo.com PRODUCT APPROVAL INFORMATION SHEET Roick Residence 525 Atlantic Beach Court Atlantic Beach, FL 32233 Manufacturer Description Limitation of Use FL# Exterior Doors In Swing Front Door Brannen Millworks OXO 8'-0" Inswing Opaque door w/Sidelights HVHZ - Yes DP+55 /-60 FL 15737.2 In Swing Patio Doors Marvin 3080 Wood Ultrex out-swing french door HVHZ - No DP+50/-50 FL 10196.11 Out Swing Patio Doors Marvin 3080 Wood Ultrex out-swing french door HVHZ - No DP+50/-50 FL 10196.11 Sliding Glass Doors PGT 20080 5470 Series SLGD HVHZ - No DP+39 /-60 FL 21179.1 Garage Door Overhead Door 9' x 7' Steel 0/H door HVHZ - No DP +19.1/-20.6 FL 16798 Windows Casement Window Andersen 400 Series Casement Windows HVHZ - No DP+40/-40 FL 12496.2 Double Hung Andersen Tilt Wash 400Series Double Hung HVHZ - No DP+40/-40 FL 15752.2 Roofing Products Underlayment Polyglass Polyglass TU Max HVHZ - No FL 5259.R0 Standing Seam metal Drexle Metals Corp. Snap-Clad .040 AL standing seam HVHZ - Yes FL 17284.5 Wall Siding 18" re-squared & re-butted (R&R) Red #1 Cedar Shingles N/A Structural Columns Perm-A-Cast Columns HB& G Building Products 12" Perm-a-Cast Tuscan Columns HVHZ - No FL 3102.1 cLJDDAG4t? OFFICE UUr .:I1 --74,; , //' y /1,-. s -4e- ro nsfru \" fNovember 1, 2018 Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach,FL 32233 RE: Roick Residence: 533 Atlantic Beach Court; Permit#RES 18-0354 Dear Mike, The purpose of this letter is to confirm all parties: owner,builder and electrical contractor have reviewed and clearly understand Chapter 39 of the 6th Edition 2017 FBC as it pertains to those receptacle serving the kitchen countertops,island and peninsular countertops. If necessary,the alternative method to meet the requirements of receptacles will be the UL listed pop-ups mounted on the countertop surf ace. The requirements for quantities and spacing of electrical receptacles will be adhered to. All the best, "-- )1( ti - -/- q'Y'vj)( Matthew F. Fennell H.Michael Adamson President,Claddagtonstructors,Inc. Vice Presiden United E ctric Co.,Inc.U A / 'i .-/1 ',,3- es 1�.i operty owner phone fax 3997 America Avenue •Jacksonville Beach,Florida 32250 904.241.1012 904.242.9344 ()71- iL,E e, f v4y ES ICC EVALUATION Most Widely Accepted and Trusted � SERVICE ICC-ES Report ESR-3375 ICC-ES I (800) 423-6587 I (562) 699-0543 I www.icc-es.org Reissued 08/2016 This report is subject to renewal 08/2018. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00—THERMAL INSULATION REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD, #538 SPRING, TEXAS 77388-4405 EVALUATION SUBJECT: SUCRASEALTM 0.5 AND SES FOAM 0.5 LB SPRAY: SPRAY-APPLIED POLYURETHANE FOAM PLASTIC INSULATION ICC ICC ICC LE:—.g4**) u ;e ! PMG LISTED Look for the trusted marks of Conformity! =�= :i�iiT♦ "2014 Recipient of Prestigious Western States Seismic Policy Council Nun rD WSSPC Award in Excellence" €�atEeaaa`�NCI (WSSPC) A Subsidiary of cooEcouac�e SCC Accredited ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not CB-PIS specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a ANSI recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as ANSI Accr<dR<d P opr OCP$ to any finding or other matter in this report, or as to any product covered by the report. PRODUCT CITATION AccrAdUE CCN j_, Copyright © 2016 ICC Evaluation Service, LLC. All rights reserved. ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3375 Reissued August 2016 This report is subject to renewal August 2018. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE crawl spaces when installed as described in Section 4.4. PROTECTION Under the IRC, the insulation may be used as air- Section: 07 21 00—Thermal Insulation impermeable insulation when installed as described in Section 3.4. SES Foam 0.5 lb Spray is identical to REPORT HOLDER: SucrasealTM 0.5. Wherever SucrasealTM 0.5 is mentioned, the same property applies to SES Foam 0.5 lb Spray. SES FOAM 3.0 DESCRIPTION 4008 LOUETTA ROAD,#538 SPRING,TEXAS 77388-4405 3.1 General: (713)239-0252 SucrasealTM 0.5 spray foam insulation is a two- www.sesfoam.com component, open cell, one-to-one-by-volume spray- EVALUATION SUBJECT: applied polyurethane foam system with a nominal density of 0.5 pcf (8.0 kg/m 3). The insulation's liquid components SUCRASEALTM 0.5 AND SES FOAM 0.5 LB SPRAY: are supplied in nominally 55-gallon drums, labeled as "A" SPRAY-APPLIED POLYURETHANE FOAM PLASTIC component or "B" component. The insulation components INSULATION have a shelf life of six months when stored in unopened containers at temperatures between 70°F (21°C) and 90°F 1.0 EVALUATION SCOPE (32°C). The attributes of the insulation have been verified as 1.1 Compliance with the following codes: conforming to the provisions of ICC 700-2008 Section • 2012 and 2009 International Building Code®(IBC) 703.2.1.1.1(c) as an air impermeable insulation. Note that decisions on compliance for those areas rest with the user • 2012 and 2009 International Residential Code®(IRC) of this report. The user is advised of the project-specific • 2012 and 2009 International Energy Conservation provisions that may be contingent upon meeting specific Code®(IECC) conditions, and the verification of those conditions is outside the scope of this report. These codes or standards • Other Codes(see Section 8.0) often provide supplemental information as guidance. Properties evaluated: 3.2 Surface-burning Characteristics: • Surface burning characteristics At a maximum thickness of 4 inches (102 mm) and a nominal density of 0.5 pcf, the insulation has a flame- • Physical properties spread index of 25 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM E84. • Thermal resistance (R-values) Thicknesses for wall cavities and ceiling cavities are not • Air permeability limited when the insulation is covered with a minimum 1/2-inch-thick (12.7 mm) gypsum board installed in • Exterior walls in Types I-IV construction accordance with the applicable code. 1.2 Evaluation to the following green standard: 3.3 Thermal Resistance(R-values): • 2008 ICC 700 National Green Building StandardTM (ICC The insulation has thermal resistance(R-values)at a mean 700-2008) temperature of 75°F(24°C) as shown in Table 1. Attributes verified: 3.4 Air Permeability: • See Section 3.1 The insulation, at a minimum thickness of 3 inches (76 mm), is considered air-impermeable in accordance 2.0 USES with IRC Section R202, based on testing in accordance with ASTM E283. SucrasealTM 0.5 spray polyurethane foam plastic insulation 3.5 DC 315 Fireproof Paint: is used as a nonstructural thermal insulating material in buildings of Type I, II, Ill, IV and V (IBC) construction, and DC 315 Fireproof Paint is manufactured by International in dwellings built under the IRC. The insulation is for use in Fireproof Technology, Inc., and is a water-based coating wall cavities and floor/ceiling assemblies, and in attics and supplied in 5-gallon (19 L) pails and 55-gallon (208 L) ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as COP to any finding or other matter in this report,or as to any product covered by the report. Namt ==.-= Copyright©2016 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 4 { ESR-3375 I Most Widely Accepted and Trusted Page 2 of 4 drums and has a shelf life of six months when stored in a coating. The coating is applied in one or more coats with factory-sealed container at temperatures between 50°F brush, roller or airless spray equipment. (10°C)and 90°F (32°C). 4.3.2.2 Application with FireShell® F10E: The thickness 3.6 FireShell®F10E: of the foam plastic applied to the underside of roof FireShell® F10E is manufactured by TPR2, and is a water- sheathing and to vertical wall surfaces must not exceed based coating supplied in 5-gallon (19 L) pails and 111/2 inches (292 mm). The foam plastic must be covered 55-gallon (208L) drums and has a shelf life of one year on all surfaces with FireShell® F10E at a minimum when stored in a factory-sealed container at temperatures thickness of 20.0 mils (0.51 mm) wet film thickness above 45°F (7°C). [14 mils (0.36 mm) dry film thickness] with a minimum application rate of 1.25 gal/100 ft2. The coating must be 4.0 INSTALLATION applied over the SucrasealTM 0.5 insulation in accordance 4.1 General: with the coating manufacturer's published instructions and SucrasealTM 0.5 spray insulation must be installed in this report. Surfaces to be coated must be dry, clean and accordance with the manufacturer's published installation free ofdirt, loose debris and other substances that could interfere with adhesion of the coating. The The coating is instructions and this report. A copy of the manufacturer's applied in one or more coats with brush, roller or airless published installation instructions must be available at all spray equipment. times on the jobsite during installation. 4.2 Application: 4.4 Attics and Crawl Spaces: The insulation is spray-applied at the jobsite using a 4.4.1 Application with a Prescriptive Ignition Barrier: volumetric positive displacement pump as identified in the When SucrasealTM 0.5 spray is installed within attics and SucrasealTM 0.5 spray application manual. The insulation crawl spaces, where entry is made only for service of components must be stored at temperatures between utilities, an ignition barrier must be installed in accordance 70°F (21°C) and 90°F (32°C) for several days before with IBC Section 2603.4.1.6 or IRC Section R316.5.3 or application. The insulation must not be used in areas that R316.5.4, as applicable, except when the installation is in have maximum in-service temperatures greater than 180°F accordance with Section 4.4.2 or Section 4.4.3. The (82°C). The insulation must not be used in electrical outlet ignition barrier must be consistent with the requirements or junction boxes or in contact with water (e.g., rain, for the type of construction required by the applicable condensation, ice, snow) or soil. The substrate must be code, and must be installed in a manner so that the foam free of moisture, frost or ice, loose scales, rust, oil, grease plastic insulation is not exposed. SucrasealTM 0.5 spray or other surface contaminants. The insulation can be insulation at a minimum thickness of 3 inches (76 mm) installed in one pass to the maximum thickness. The may be installed in unvented attics in accordance with spray-applied foam insulation must be protected from 2012 IRC Section R806.5 (2009 IRC Section R806.4), as weather during and after installation. applicable. 4.3 Thermal Barrier: 4.4.2 Application without a Prescriptive Ignition Barrier: Where the spray-applied insulation is installed in 4.3.1 Application with a Prescriptive Thermal Barrier: accordance with this section or Section 4.4.3, the following SucrasealTM 0.5 spray insulation must be separated from conditions apply: the interior of the building by an approved thermal barrier of 1/2-inch-thick (12.7 mm) gypsum wallboard or an a) Entry to the attic or crawl space is to service utilities, equivalent 15-minute thermal barrier complying with. and and no storage is permitted. installed in accordance with, IBC Section 2603.4 or IRC b) There are no interconnected attic or crawl space Section R316.4, as applicable, except when the installation is in accordance with Section 4.3.2.Within an attic or crawl areas. space, installation must be in accordance with Section 4.4. c) Air in the attic or crawl space is not circulated to other 4.3.2 Application without a Prescriptive Thermal parts of the building. Barrier: The prescriptive 15-minute thermal barrier may be d) Attic ventilation is provided when required by IBC omitted when installation is in accordance with this section. Section 1203.2 or IRC Section R806, except when The insulation and coating may be spray-applied to the air-impermeable insulation is permitted in unvented interior facing of walls and the underside of roof sheathing attics in accordance with 2012 IRC Section R806.5 or or roof rafters, and in crawl spaces, and may be left 2009 IRC Section R806.4. Under-floor (crawl space) exposed as an interior finish without a prescribed ventilation is provided when required by IBC Section 15-minute thermal barrier or prescribed ignition barrier 1203.3 or IRC Section R408.1, as applicable. when the installation is in accordance with either Sections 4.3.2.1 or 4.3.2.2. e) Combustion air is provided in accordance with International Mechanical Code®Section 701. 4.3.2.1 Application with DC 315 Fireproof Paint: The thickness of the foam plastic applied to the underside of In attics, the insulation may be spray-applied to the roof sheathing and to vertical wall surfaces must not underside of roof sheathing or roof rafters, and/or vertical exceed 111/2 inches (292 mm). The foam plastic must be surfaces, and in crawl spaces the insulation may be spray- covered on all surfaces with DC 315 Fireproof Paint at a applied to the underside of floors and/or vertical surfaces minimum thickness of 18.0 mils (0.47 mm) wet film as described in this section. The thickness of the foam thickness [12 mils (0.30 mm) dry film thickness] with a plastic applied to the underside of the top of the space minimum application rate of 1.12 gal/100 ft2. The coating must not exceed 12 inches (305 mm). The thickness of the must be applied over the SucrasealTM 0.5 insulation in foam plastic applied to vertical surfaces must not exceed accordance with the coating manufacturer's published 111/2 inches (292 mm). The foam plastic may be installed instructions and this report. Surfaces to be coated must be without a covering or coating. The insulation may be dry, clean and free of dirt, loose debris and other installed in unvented attics in accordance with 2012 IRC substances that could interfere with adhesion of the Section R806.5 (2009 IRC Section R806.4). The ignition ESR-3375 I Most Widely Accepted and Trusted Page 3 of 4 barrier in accordance with IBC Section 2603.4.1.6 or IRC 6.0 EVIDENCE SUBMITTED Section R316.5.3 may be omitted. 6.1 Data in accordance with the ICC-ES Acceptance 4.4.3 Use on Attic Floors: SucrasealTM 0.5 spray Criteria for Spray-applied Foam Plastic Insulation insulation may be installed exposed at a maximum (AC377), dated November 2012 (editorially corrected thickness of 111/2 inches (292 mm) between joists in attic April 2013), including reports of tests in accordance floors. The ignition barrier in accordance with IBC Section with Appendix X of AC377. 2603.4.1.6 or IRC Section R316.5.3 may be omitted. The 6.2 Reports of room corner fire-testing in accordance with insulation must be separated from the interior of the NFPA 286. building by an approved thermal barrier. 4.5 Exterior Walls of Type I, II, Ill and IV Construction: 6.3 Report of air permeance testing in accordance with ASTM E283. 4.5.1 General:When used on walls of Type I, II, Ill and IV 6.4 Report of potential heat testing in accordance with exterior wall construction, the SucrasealTM 0.5 spray- NFPA 259. applied foam insulation must comply with Section 2603.5 of the IBC and this section. The potential heat 6.5 Report of fire propagation testing in accordance with of SucrasealTM 0.5 spray-applied foam insulation is NFPA 285. 466 Btu/ft2 (5.26 MJ/m2) per inch of thickness when tested 6.6 Engineering evaluation extending NFPA 285 testing in accordance with NFPA 259. to various exterior wall constructions. 4.5.2 Specific Wall Assemblies: Wall assemblies must 7.0 IDENTIFICATION be as described in Table 2. Components of the SucrasealTM 0.5 spray polyurethane 5.0 CONDITIONS OF USE foam plastic insulation are identified with the The SucrasealTM 0.5 spray polyurethane foam plastic manufacturer's name (SES Foam) and address; the date insulation described in this report complies with, or is a of manufacture or the lot number; the product trade name suitable alternative to what is specified in, those codes (SucrasealTM 0.5); the mixing instructions; the density; the listed in Section 1.0 of this report, subject to the following flame-spread and smoke-developed indices; and the conditions: evaluation report number(ESR-3375). 5.1 The insulation must be installed in accordance with 8.0 OTHER CODES the manufacturer's published installation instructions, In addition to the codes referenced in Section 1.0, the this evaluation report and the applicable code. If there products in the report were evaluated for compliance with are any conflicts between the manufacturer's the requirements of the following codes: published installation instructions and this report, this report governs. • 2006 International Building Code® 5.2 The insulation must be separated from the interior of • 2006 International Residential Code® the building by an approved 15-minute thermal ■ 2006 International Energy Conservation Code® barrier, as described in Section 4.3.1, except when the installation is in accordance with Section 4.3.2. The products comply with the above mentioned codes as Installation in an attic or crawl space must be as described in Sections 2.0 through 7.0 of this report, with described in Section 4.4. revisions as noted below: 5.3 The insulation must not exceed the thicknesses noted • Application with and without a Prescriptive Thermal in Sections 3.2,4.3, and 4.4. Barrier: See Section 4.3, except the approved thermal barrier must be installed in accordance with Section 5.4 The insulation must be protected from exposure to the R314.4 of the 2006 IRC. weather during and after application. ■ Application with a Prescriptive Ignition Barrier: See 5.5 The insulation must be applied by contractors certified Section 4.4.1, except an ignition barrier must be by SES Foam. installed in accordance with Section R314.5.3 or 5.6 Use of the insulation in areas where the probability of R314.5.4 of the 2006 IRC. termite infestation is "very heavy" must be in • Application without a Prescriptive Ignition Barrier: accordance with 2012 IBC Section 2603.9 (2009 IBC See Section 4.4.2, except that combustion air is Section 2603.8) or IRC Section R318.4, as applicable. provided in accordance with Sections 701 and 703 of 5.7 Jobsite certification and labeling of the insulation must the 2006 IECC. comply with IRC Sections N1101.4 and N1101.4.1 ■ Protection against Termites: See Section 5.6, except and IECC Sections R303.1.1 and 303.1.1.1, as use of the insulation in areas where the probability of applicable. termite infestation if"very heavy" must be in accordance 5.8 When use is on exterior wall of buildings of Type I, II, with Section R320.5 of the 2006 IRC. III or IV construction, construction must be as ■ Jobsite Certification and Labeling: See Section 5.7, described in Section 4.5 and Table 2. except jobsite certification and labeling must comply 5.9 A vapor retarder must be installed in accordance with with Sections 102.1.1 and 102.1.1.1, as applicable, of the requirements of the applicable code. the 2006 IECC. 5.10 SucrasealTM 0.5 spray polyurethane foam plastic insulation is produced in St. Louis, Missouri, under a quality-control program with inspections by ICC-ES. ESR-3375 I Most Widely Accepted and Trusted Page 4 of 4 TABLE 1—THERMAL RESISTANCE(R-VALUES'2) THICKNESS(inches) R-VALUE(°F•ft2•h/Btu) 1 4.0 2 7.6 3 11 3.5 13 4 15 5 19 6 22 7 26 8 30 9 33 10 37 11 41 12 44 For SI: 1 inch=25.4 mm, 1°F•ft2•h/Btu=0.176 110K•m2/W. 1R-values are calculated based on tested K values at 1-and 3.5-inch thicknesses. 2R-values greater than 10 are rounded to the nearest whole number. TABLE 2—NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES WALL COMPONENT MATERIALS 1 –Concrete wall 2–Concrete Masonry wall Base wall system–Use either 3–1 layer of 5/8-inch thick Type X gypsum wallboard installed on the interior side of minimum 3-5/8 inch 1,2,or 3 deep minimum 20 gauge thick steel studs spaced a maximum of 24-inch on center. Lateral bracing installed minimum every 4 ft.vertically or as required.Wall stud cavities shall be filled at each floor line with minimum 4 lb/ft3 mineral-fiber insulation friction fit between steel wall studs. Resilient Channel–For use 1 –None with Base Wall System 3 above 2–Double leg"hat"shaped steel resilient channel installed perpendicular to the wall studs(interior side –Use either 1 or 2 only)and spaced a maximum of 24-inches on center between steel studs and Type X gypsum wallboard. Entire perimeter of window opening to be framed with resilient channel. Perimeter Fire Barrier System Perimeter fire barrier system complying with Section 715.4 of the 2012 IBC shall be installed to fill the void between the edge of the concrete floor slab and the interior surface of the exterior wall assembly. Full wall stud cavity depth or less of SucraSealTM 0.5 spray-applied foam plastic insulation applied using Wall Stud Cavity Insulation exterior gypsum sheathing as the substrate and covering the width of the cavity and the inside of the steel wall stud framing flange. Exterior sheathing–For Base5/8-inch thick Type X exterior type gypsum sheathingcomplying with ASTM C1177. Wall System 3 above yp yp com p y g 1 –Any non-combustible exterior wall covering material Exterior Wall Covering–Use 2–Any non-combustible exterior wall covering system with a combustible WRB that has successfully been either 1,2,or 3 tested in accordance with NFPA 285. (see Note 1 below) 3–Metal Composite Material(MCM) Mitsubishi Plastic Composites America, Inc.,Alpolic/fr wall panels (see ICC-ES ESR-2653)or Alcoa Architectural Products Reynobond FR 6-mm panels(see ICC-ES ESR- 3435)where there is no exterior insulation in the cavity behind the panels. Flashing of window,door and As an option,flash around window,door and other exterior penetrations with limited amounts of maximum other exterior wall penetrations. 12-inch wide acrylic,asphalt or butyl-based flashing tape or liquid applied membrane material. For SI: 1 inch=25.4 mm; 1 pcf= 16.0 kg/m3. Note 3: Exterior wall coverings shall be installed in accordance with the manufacturer's installation requirements and must comply with the applicable provisions of IBC Chapter 14 and IRC Chapter 7. E'c ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3375 FBC Supplement Reissued August 2016 Revised August 17, 2016 This report is subject to renewal August 2018. www.icc-es.org I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD,#538 SPRING,TEXAS 77388-4405 (713)239-0252 www.sesfoam.com EVALUATION SUBJECT: SUCRASEALTM 0.5 AND SES FOAM 0.5 LB SPRAY: SPRAY-APPLIED POLYURETHANE FOAM PLASTIC INSULATION 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that SucraSeal 0.5 spray polyurethane foam plastic insulation, recognized in ICC-ES master evaluation report ESR-3375, has also been evaluated for compliance with the codes noted below. Applicable code editions: • 2014 Florida Building Code—Building • 2014 Florida Building Code—Residential 2.0 CONCLUSIONS The SucraSeal 0.5 spray polyurethane foam plastic insulation (also known as SES Foam 0.5 lb Spray), described in Sections 2.0 through 7.0 of the master evaluation report ESR-3375, complies with the Florida Building Code—Building and the Florida Building Code—Residential, provided the design and installation are in accordance with the 2012 International Building Code® (IBC) and 2012 International Residential Code® (IRC) provisions noted in the master report under the following condition:. Installation must meet the requirements of Sections 1403.8 and 2603.9 of the Florida Building Code—Building and Sections R318.7 and R318.8 of the Florida Building Code—Residential, as applicable. Use of Sucraseal 0.5/SES Foam 0.5 lb spray-applied polyurethane foam plastic insulation has also been found to be in compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code—Building and the Florida Building Code—Residential. For products falling under Florida Rule 9N-3, verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued August 2016. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed ICC as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as ANSI to any finding or other matter in this report,or as to any product covered by the report. "'urc`at. Copyright©2016 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 1 .-;7 ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3375 Seal and Insulate with ENERGY STAR®Supplement Reissued August 2016 This report is subject to renewal August 2018. www.icc-es.orq I (800) 423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD,#538 SPRING,TEXAS 77388-4405 (713) 239-0252 www.sesfoam.com EVALUATION SUBJECT: SUCRASEALTM 0.5 AND SES FOAM 0.5 LB SPRAY: SPRAY-APPLIED POLYURETHANE FOAM PLASTIC INSULATION 1.0 EVALUATION SCOPE Conformance to the following: Seal and Insulate with ENERGY STAR® Program—Definitions and Testing Requirements for Residential Insulation, Version 1.0 Properties evaluated: • Thermal resistance • Surface-burning characteristics 2.0 PURPOSE OF THIS SUPPLEMENT This supplement is issued to certify that the insulation products described in Sections 2.0 through 8.0 of the master report ESR-3375 have been reviewed for compliance with the requirements of the Seal and Insulate with ENERGY STAR® Program, as set forth in the document Definitions and Testing Requirements for Residential Insulation, Version 1.0. The insulation product covered by this supplement is defined as"Spray or Pour Foam Insulation." The requirements for testing laboratory qualification and product sampling, as well as the specific material and test standards and editions used in this evaluation, are as set forth in the applicable documentation noted in Section 6.0 of the master evaluation report. 3.0 DEFINITIONS The following definitions are from Definitions and Testing Requirements for Residential Insulation, Version 1.0, and are applicable to the subject of this report. 3.1 General Definitions: Insulation: Any material mainly used to slow down heat flow. It may be mineral or organic, fibrous, cellular, or reflective (aluminum foil). It may be in rigid, semi-rigid, flexible, or loose-fill form. 3.2 Insulation Product Definitions: Spray or Pour Foam Insulation: A thermal insulating material that is sprayed or poured (as a gel or foamy liquid) into place, and expands or sets into a cellular foam and cures at the point of installation through a chemical reaction. Foamed materials include, but are not limited to polyurethane, polyisocyanurate, phenolic, and cementitious insulation. 3.3 Insulation Performance Definitions: R-value: The inverse of the time rate of heat flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces, under steady state conditions, per unit area. For the purposes of the ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specificalh addressed.nor are then to be construed as an endorsement of the subject of the report or a recommendation for its use There is no warranty by ICC Evaluation Service,LLC,express or implied,as =.U, to any finding or other matter in this report,or as to any product covered by the report. '"'�arE"t'.Q ,, Copyright©2016 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 6 ESR-3375 I Most Widely Accepted and Trusted Page 2 of 6 Seal and Insulate with ENERGY STAR®program, Imperial units will only be accepted [(h•ft2.°F)/Btu]. Smoke-Development Index: The characteristic of a material to emit smoke when exposed to flame or fire compared to red oak and inorganic cement. Flame-Spread Index: The characteristic of a material to resist the spreading of flames when exposed to flame or fire compared to red oak and inorganic cement. 3.4 Thermal Resistance: The insulation has the thermal resistance R-values as noted in Table 1 of ESR-3375, based upon testing. 3.5 Installation: 3.5.1 General: The installation of the insulation must be in accordance with the requirements set forth in Sections 4.0 and 5.0 (as applicable) of ESR-3375. The insulation is manufactured on-site by spray polyurethane foam applicators meeting the qualification requirements of SES Foam. The following information on personal protective equipment and ventilation requirements is reprinted from the SES Foam published installation instructions! "F. SAFETY 3. PERSONAL PROTECTIVE EQUIPMENT(PPE): a. Skin:Wear gloves, coveralls, apron and boots as necessary to prevent contact of liquid components or partially-cured SPF with skin.When handling liquid components, gloves should be made of nitrile, neoprene, butyl or PVC. b. Eyes: Protect eyes while handling liquid components or spraying with safety goggles or safety goggles and a face shield. During spray application,eye protection may be provided by a full-face or hood respirator. c. Respiration: Firms engaged in the application of SES Foam systems must have a written respiratory protection program for employees engaged in handling or applying SES Foam materials. Depending on the situation, respiratory protection may include dust masks, air-purifying respirators (APR), powered air-purifying respirators (PAPR), or supplied-air respirators (SAR). 4. VENTILATION: Provide ventilation and other engineering controls to exhaust vapors from work areas and to protect building occupants and other trades." 3.5.2 Occupancy Time after Installation: The re-entry or re-occupancy time shall be in accordance with the manufacturer's installation instructions, which state the following: "G. RE-ENTRY SucrasealTM 0.5 reacts and cures within seconds of application. Re-entry times will vary depending on factors including ventilation. Typically, ventilation is continued for 24 hours following the conclusion of spray application and re-entry may occur at that time." 3.5.3 Figures: The figures shown represent general installations of the insulation in the following applications: above-grade wall, below-grade wall, vented and unvented crawl space, unvented cathedral ceiling, and vented and unvented attic. These figures are for illustration purposes and are not to be construed or used as construction documents. This supplement expires concurrently with the master report, reissued August 2016. ESR-3375 I Most Widely Accepted and Trusted Page 3 of 6 .� °vim °v- o�-° °vim °.,- °� o� °vimIi X00°0°0°000oo0O 01' 00°00°00' > °O °C 000,°0 00 00 0 Interior Partition >00°°o°oc o°°o°° o 00°0000 0000000c --.. Interior Finished Surface 00°00000, (1/2-inch Sheetrock) 0 0 0 00Q 00000 000000°°00, 00 0° 0000°°00 SUCRASEALTM 0.5 or 00000000 SES Foam 0.5 lb Spray o�°o°o°°o oOp00"°C 000000 00 Exterior Sheathing ° 000000 . nflrd&'n00 SUCRASEAL"0.5 ABOVE GRADE WALL INSULATION SES 05-1 062914 SES FOAM 0.5 LB SPRAY ESR-3375 I Most Widely Accepted and Trusted Page 4 of 6 00 <> .4.MasonryBlock ------1.0.••- /\V ,. (Typical) ------1.0.••- ,.� i . / ,.,- Interior Finish Surface (1/2-Inch Sheetrock) o ,/ o • / 2'x 4"Studs `� '•': - SUCRASEALi"Ing ly to *14 too: SUCRASEALT.0.5 BELOW GRADE WALL INSULATION SES 05-2 062914 SES FOAM 0.5 LB SPRAY (Insulation on Interior Side of Wall) Baffle to provide �,� air space between r' Thermal insulation and roof - Barrier' deck. (as required jam% by local code) \ :...5-,,,,, ,_.;. ---- ••o'tl 10000ap000o000000000ao•o0ouo•oo.o0000000000000000 OOOOOOtlO00pOG0000 O O Oo0 O OoQO000 OQOotl00 0000000000000000000'0000000000000000000 //- / !GOp060opa \ 04.:i::2:°4 O 0004 00000004 °gom.gc SUCRASEALTM 0.5 or . 4 SES Foam 0.5 lb Spray /i!/////////I//!l/!IO// //////.77////LT/TT/Tl 000000aO ' og0000 0c 0oo0o0c u0o00000c 000000004 000 000 00000000c 0 00°0� j °0000000 00000000c 0004 Vented Soffit `°tl0°0` 000 000000 00000004 / i0000o 0 c 0 00000 °0'a0,,, `Where attic entry is for the 0400000 ',,,00goN service of utilities only,thermal SES Foam 0.5 lb Spray 000000004 °o°�,o,, and igniton barrier on the attic .9.9.2.5 I side of the spray foam surface may be omitted. SALTM 0.5 VENTED ATTIC:FLOOR/SOFFIT SES 05-3 062914 SESES FOAM 0.5 LB SPRAY ESR-3375 I Most Widely Accepted and Trusted Page 5 of 6 Subfloor SUCRASEALTM 0.5 or SES Foam 0.5 lb Spray ` - o;oa 00° ao`"oao 0 0 0 00000evo ^"°°^"''o Header--- 4 ----_ °:::g!g 0 oo.o.° aa%g oogogpJ Sill v��• ►♦♦♦♦♦♦♦♦ -,7- Joist Floor Cross Section r►i♦♦♦♦♦ Thermal Barrier* as required b Exterior Grade � `��� local ode) y 4. X //\�/\\/ii♦♦ice ►♦�♦�♦♦♦� 6"Min .. ..• ♦♦♦♦♦♦ Footer�� �♦�♦�♦�♦�♦ ,Vapor Barrier ♦ Y♦♦ .•.• •, :•. . // //. `Where crawlspace entry is for the . • :� +• //\ \\//\\///; service of utilities only,thermal • -: ,•,a''°,//\/2\\/`moi/ and igniton barrier on the crawlspace side of the spray foam surface may be omitted. SUCRASEALTM0.5 SES FOAM 0.5 LB SPRAY CRAWLSPACE:VENTED SES 05-4 062914 1 4 Subfloor l 1T�i= Header 1tv ie'et:gge?"' i li:ifigat Sill t.�s°o ►♦ ilba'. Joist ��i;'o , Thermal Barrier" 1e8%aSa -- (as required by ° oo Exterior Grade ♦ oogo ,vo ,,i local code) A\///A\//A N,ki �.°°°o°°oo , TM Ag o:° SUCRASEAL 0.5 or ♦ W"4o k, SES Foam 0.5 lb Spray `♦♦/4 08° ♦♦1♦4. Ivor —r- Footer- 4* 6"Min Vapor Barrier ''...'- .'>�y/\v' ' 'Where crawlspace entry is for the service of utilities only,thermal and igniton barrier on the crawlspace side of the spray foam surface may be omitted. SUCRASEAL 0.5 CRAWLSPACE:UNVENTED SES 05-5 062914 SES FOAM 0.5 LB SPRAY ESR-3375 I Most Widely Accepted and Trusted Page 6 of 6 Note:In cold climates,embed metal connector plates in spray foam to prevent wintertime condensation. SUCRASEALTM 0.5 or ''a SES Foam 0.5 lb Spray . • \ 0000 � , 4°4\ O,,4o0 R lr .0404' —._— ".'404. - ,44t'o u� - O4 Roof Sheathing --A,;: tl' r: Truss Top Cord/ O4p4 . \ \ \ Rafter ° V / 0 •4o4°rte\ \ °U° \In nnnnn ,nnnnnn nnnnnn T Al°1 i \\_Thermal Barrier` (as required by local code) Note:Local building code may require the use of a vapor retarder in cold climate zones. Ceiling/Thermal Barrier 'Where attic entry is for the `�__ service of utilities only,thermal as required by local building code. and igniton barrier on the attic side of the spray foam surface may be omitted. SALTM 0.5 UNVENTED ATTIC/INSULATED ROOF DECK SES 05-6 062914 SESES FOAM 0.5 LB SPRAY /�\ SUCRASEALTM 0.5 or , 'O Op0p O SES Foam 0.5 lb Spray U o�1�O 0 o. O to specified thickness. 0•00• 0 • • ' • •0 0 OOOO� Roof Sheathing �. 0 0 0 0 0 0 /fl00000 4O O O J 0 z / Thermal Barrier as Rafter O �' �/ C � � required by code. /= ! ,fl O is r A // ` \ Note:The local building code \`may require the installation of a vapor barrier in cold climate // zones. i SUCRASEALnt0.5 CATHEDRAL CEILING SES 05-7 SES FOAM 0.5 LB SPRAY 062914 Th ICC EVALUATION Most Widely Accepted and Trusted S SERVICE ICC-ES Report VAR-1030 ICC-ES I (800) 423-6587 I (562) 699-0543 I www.icc.-•s.org Reissued 09/2015 This report is subject to renewal 09/2017. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00—THERMAL INSULATION REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD, #538 SPRING, TEXAS 77388-4405 EVALUATION SUBJECT: SES FOAM 0.5 LB SPRAY POLYURETHANE FOAM PLASTIC INSULATION ICC ICC - ICC PMG LISTED Look for the trusted marks of Conformity! :== "2014 Recipient of Prestigious Western States Seismic Policy Council �w�, (WSSPC)Award in Excellence" A Subsidiary of CODEcoaxcii ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not I scc r.d specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a AWSI recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as ANSI AcveSI Program OCPs to any finding or other matter in this report, or as to any product covered by the report. PRODUCT CIR,.C,,,aN AccrBdRecce $1000 Copyright © 2015 ICC Evaluation Service, LLC. All rights reserved. At-c-. ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES VAR Environmental Report VAR-1030 Reissued September 2015 This report is subject to renewal September 2017. www.icc-es.org/ep 1800-423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE high-pressure, plural component SPF application PROTECTION equipment. The bio-based content is as set forth in Table 1 Section: 07 21 00—Thermal Insulation of this report. REPORT HOLDER: 4.0 CONDITIONS 4.1 Code Compliance: SES FOAM See ICC-ES report ESR-3375 for compliance of the SES 4008 LOUETTA ROAD,#538 Foam 0.5 lb Foam S Polyurethane Foam Plastic Insulation SPRING,TEXAS 77388-4405 (713)239-0252 with code requirements. www.sesfoam.com 4.2 Green Codes, Standards and Rating Systems Eligibility: EVALUATION SUBJECT: The information presented in Tables 2 through 5 of this report provides a matrix of areas of evaluation and SES FOAM 0.5 lb SPRAY POLYURETHANE FOAM corresponding limitations and/or additional project-specific PLASTIC INSULATION requirements, and offers benefits to individuals who are 1.0 EVALUATION SCOPE assessing eligibility for compliance. The final interpretation of the specific requirements of the Compliance with the following environmental criteria: code rests with the Authority Having Jurisdiction. ICC-ES Environmental Criteria for Determination of Compliance for items noted as "Verified Attribute" is Bio-based Material Content(EC102), dated March 1, 2012. subject to any conditions noted in the tables. Decisions on Compliance eligibility with the applicable sections of compliance for those items noted as "Eligible for Points" in the following codes and standards: Tables 2 through 5 rests with the user of this report, and those items are subject to the conditions noted. The user is • 2012 International Green Construction Coder" (IgCC) advised of the project-specific provisions that may be (see Table 2 for details) contingent upon meeting specific conditions, and the • ASHRAE Standard 189.1 – 2009 (see Table 3 for verification of those conditions is outside the scope of this details) report. • National Green Building Standard (ICC 700-2008) (see Due to the variability of costs and volume, the bio-based Table 4 for details) content percentage listed in this report is based upon weight (mass). The use of cost or volume as the method • ANSI/GBI 01-2010, Green Building Assessment for calculation is outside the scope of this report. Protocol for Commercial Buildings (see Table 5 for details) 5.0 BASIS OF EVALUATION 2.0 USES The information in this report, including the "Verified Attributes," is based upon submission of documentation SES Foam 0.5 lb Foam S Polyurethane Foam Plastic demonstrating compliance with the requirements set forth Insulation is used as nonstructural thermal insulating in ICC-ES EC102. (Evaluation applies to IgCC Section material in wall cavities, floor/ceiling assemblies, or in 505.2.4, item 3; ASHRAE 189.1 Section 9.4.1.3; ICC 700 attics and crawl spaces. See ICC-ES report ESR-3375 for Section 606.1;ANSI/GBI-01 Section 10.1.2.2.) more information on uses and applications. 6.0 IDENTIFICATION 3.0 DESCRIPTION Containers of SES Foam 0.5 lb Foam S Polyurethane SES Foam 0.5 lb spray-applied polyurethane foam plastic Foam Plastic Insulation are identified by a label bearing the insulation is a two-component, open-cell, water-blown, SES Foam name and address, product name, spray-applied polyurethane foam (SPF) with a nominal manufacturing date, manufacturing location and the VAR density of 0.5 lb/ft3. The foam is sprayed in place using Environmental Report number(VAR-1030). ICC-ES Verification cif Attributes Reports are issued under the ICC-ES VAR Environmental Program.These reports are not to be construed as representing aesthetics or any other 11 attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered br the report. rjr aeharc Copyright©2015 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 2 f, VAR-1030 I Most Widely Accepted and Trusted Page 2 of 2 TABLE 1—BIO-BASED MATERIAL CONTENT SUMMARY PRODUCT NAME %MEAN BIO-BASED CONTENT METHOD OF DETERMINATION SES Foam 0.5 lb Spray Polyurethane Foam Plastic Insulation 17%(+/-3%)1 ASTM D6866 Note: 'Based on precision and bias cited in ASTM D6866. TABLES 2 THROUGH 5 Section Possible Number Section Intent Points Conditions Of Use To Qualify For Points Finding TABLE 2—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2012 INTERNATIONAL GREEN CONSTRUCTION CODE Bio-based materials shall be those materials that comply with one or more of the following: 505.2.4 Bio-based content N/A 3.The requirements of USDA 7CFR Part 2902. • Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 3—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2009 ASHRAE STANDARD 189.1 A minimum of 5%of building materials used,based on cost,shall be biobased products. Biobased products shall comply with the minimum biobased contents of the USDA's Designation of Biobased Items for Federal Procurement[7 CFR Part 2902],contain the 9.4.1.3 Biobased products N/A "USDA Certified Biobased Product"label,or be composed of solid wood,engineered • wood,bamboo,wool,cotton,cork,agricultural fibers,or other biobased materials with at least 50%biobased content. Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 4—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2008 NATIONAL GREEN BUILDING STANDARD(ICC 700) The following biobased products are used: (h)products with the minimum biobased contents of the USDA 7 CFR Part 2902 606.1 Biobased products 3 (i)other biobased materials with a minimum of 50 percent biobased content(by weight • 8 max or volume) Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +1-3%). SES Foam 0.5 lb Spray exceeds this minimum. TABLE 5—SUMMARY OF AREA OF ELIGIBILITY WITH THE ANSI/GBI–01 (2010)STANDARD Bio-based products accounted for 1%or more of the materials used in the building. Percentage= 100 x A=B,where: A=Total cost or weight of bio-based products B=Total cost or weight of all building products 10.1.2.2 Materials content– 1 Cost or weight must be used consistently • Assemblies 7 max For USDA-designated products,products meeting or exceeding USDA's bio-based content,criteria or qualifying as USDA"BioPreferred"were used. Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. • =Verified attribute FLA. 1977 Laws FS 713.13 NOTICE of COMMENCEMENT To whom it may concern: The undersigned hereby informs all concerned that the improvements will be made to certain real property and in accordance with section 713.13 of the Florida Statutes. The following information is stated in this NOTICE of COMMENCEMENT. Description of the property: 533 Atlantic Beach Court Atlantic Beach, FL 32233 Lot#25 Atlantic Beach Country Club Unit 2 Duval County Florida RE# 1695054420 General Description of the improvements: New construction of single family home Owner: James and Tami Roick 2228 Ocean Walk Drive West Atlantic Beach, FL 32233 Owner's interest in the improvement: Personal home Fee Simple Title holder(if any other than the owner): Name: Address: (2 0.1 Contractor: CLADDAGH CONSTRUCTORS, INC. 3997 America Avenue ‘k clq Jacksonville Beach, FL 32250 Surety(if any): n/a Address: Amount of Bond$ Lending Institution providing funds for improvements: • Name: n/a Address: Person within the state of Florida designated by the owner upon who notices or other documents may be served: Name: Address: In addition to himself,the owner designates the following person to receive a copy of the Lienor's Notice as provided in section 713.13 of the Florida Statutes. (till in the owner's option) Name: Address: OWNER AlThis space reserved for recorder's use only: Signed: i'.,1. ) , Date: Before me'his day of LiariTiVir in County f Duval, State of Florida,, as personally appeared(print name here) ..190,\ Pi • M`Lk, herein by myself/person and firms that all statements and declarations herein are true and accurate. n .t- n to . An d. FLA. 1977 Laws FS 713.13 NOTICE of COMMENCEMENT To whom it may concern: The undersigned hereby informs all concerned that the improvements will be made to certain real property and in accordance with section 713.13 of the Florida Statutes. The following information is stated in this NOTICE of COMMENCEMENT. Description of the property: 533 Atlantic Beach Court Atlantic Beach, FL 32233 Lot #25 Atlantic Beach Country Club Unit 2 Duval County Florida RE# 169505-1420 General Description of the improvements: New construction of single family home Owner: James and Tami Roick 2228 Ocean Walk Drive West Atlantic Beach, FL 32233 Owner's interest in the improvement: Personal home Fee Simple Title holder(if any other than the owner): Name: Address: Contractor: CLADDAGH CONSTRUCTORS, INC. fvfx) 3997 America Avenue b Jacksonville Beach, FL 32250 . Surety(if any): n/a Address: Amount of Bond$ Lending Institution providing funds for improvements: Name: n/a Address: Person within the state of Florida designated by the owner upon who notices or other documents may be served: Name: Address: In addition to himself,the owner designates the following person to receive a copy of the Lienor's Notice as provided in section 713.13 of the Florida Statutes. (till in the owner's option) Name: Address: OWNER This space reserved for recorder's use only: Signed: d...1.... 4 , Date:ICHILM Before me'his day of Li11.1l� I ' in County bf Duval, State of Florida,. personally appeared(print name here) 1-00^4‘ ft . 1.1310 herein by myself/person and firms that all statements and declarations herein are true and accurate. Oak\ CRYSTAL BRADDOCK NvdSyki,�, • %Commission#GG 005409 (Notary ignat ire) _ ° ' Expires June 23,2020 LULL .,,:oFa�oa,. Notary ublic at Large,State o, — 0 County Bonded TtrruTroy Fain Insurance 800.3857019 My commission expires: ckQ' Qa Personally known: or Produced Identification: p J wan". • Doc#2018247067,OR BK 18566 Page 1551, Number Pages:1 Recorded 10/17/2018 11:29 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY • RECORDING $10.00