No preview available
 /
     
305 AHERN ST RES17-0264 ENERGY EFF CODE _ , RE-St -7 - 0zG4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1931 Right 10.13 Builder Name: Street: Permit Office: City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2961.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 2709.80 ft2 b.Frame-Wood,Adjacent R=19.0 252.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (946.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=19.0 946.00 ft2 6. Conditioned floor area above grade(ft2) 1931 b. N/A R= ft2 c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11. Ducts R ft2 7. Windows(267.5 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 296 a. U-Factor: Dbl,U=0.36 267.51 ft2 SHGC: SHGC=0.31 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency a.Central Unit 47.5 SEER:15.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 47.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.185 ft. Area Weighted Average SHGC: 0.310 14.Hot water systems a. Electric Cap:55 gallons 8. Floor Types (966.0 sqft.) Insulation Area EF:0.950 a.Floor over Garage R=19.0 596.00 ft2 b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 266.00 ft2 None c.other(see details) R= 104.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 57.43 Glass/Floor Area: 0.139 PASS Total Baseline Loads: 65.72 I hereby certify that the plans and specifications covered by Review of the plans and ��..`'- VE ST q '`' this calculation are in compliance with the Florida Energy specifications covered by this • ti ;, a. ;;.,,0� Code. calculation indicates compliance /4„,"...;,.�ivv� _= ••••:_^'�'; 11�� with the Florida Energy Code. : /ow/ `, ,`:i"',`"t'o:0 PREPARED BY: __Pax 7' Before construction is completed ' --- 'F,►..: _ °d t DATE: _3-22018_ this building will be inspected for t ! :a 3 compliance with Section 553.908 s *'. . � 4. , :`* I hereby certify that this buildi g, as signs 's i mpliance Florida Statutes. �"% , Co.„-----,03. �' ,'. ` • with the Florida Energy C WEto - DATE: BUILDING OFFICIAL: ( ,. ..tic_.:,,,....--,- .. DATE: �. DATE . 6 I-t?5 I - Compliance requires certification by the air handler unit manufacturer that the air handler encl re qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4 . /nd this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). C)<(./.1 90I 3/28/2018 2:42 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 0 _ I FORM R405-2017 PROJECT Title: 1931 Right Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1931 Lot# 10B Owner Name: Total Stories: 3 Block/Subdivision: Ahem Townhomes #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Permit Office: Cross Ventilation: No County: Duval Jurisdiction: Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL JACKSONVILLE INT 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 1931 17379 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1931 17379 Yes 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor over Garage Main ___ ____ 596 ft2 19 0 0 1 2 Slab-On-Grade Edge lnsulatio Main 74 ft 0 266 ft2 ---- 0 0 1 3 Raised Floor Main ____ ____ 104 ft2 19 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Flat Gravel 949 ft2 40 ft2 Medium 0.65 N 0.9 No 0 4.8 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 No attic Vented 300 946 ft2 N N 3/28/2018 2:42 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 ir --% 7 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 19 Blown 946 ft' 0.1 Wood WALLS Adjacent S ace Cavity Width Height Sheathing Framing Solar Below - p _To- WaI ype --- - R-Value._ _Ft_-In_-_-Ft-In--- _Area-----R-VaIuP__Fraction_Abs0r. (rRde% 1 W Exterior Frame-Wood Main 19 39 11 10 0 399.2 ft' 0 0.25 0.5 0 2 W Exterior Frame-Wood Main 19 52 1 9 0 468.8 ft2 0 0.25 0.5 0 3 S Exterior Frame-Wood Main 19 12 1 10 0 120.8 ft2 0 0.25 0.5 0 4 S Exterior Frame-Wood Main 19 94 9 9 0 853.0 ft2 0 0.25 0.5 0 _ 5 E Exterior Frame-Wood Main 19 19 10 10 0 198.3 ft' 0 0.25 0.5 0 _ 6 E Exterior Frame-Wood Main 19 74 5 9 0 669.8 ft2 0 0.25 0.5 0 7 - Garage Frame-Wood Main 19 28 0 9 0 252.0 ft' 0 0.25 0.01 0 - DOORS # Ornt Door Type Space Storms U ValueWidth Height Area Ft In Ft In 1 E Insulated Main None .39 3 8 24 ft2 2 - Insulated Main None .39 2 10 6 10 19.4 ft' WINDOWS Orientation shown is the entered,Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.36 0.31 N 16.5 ft' 4 ft 0 in 2 ft 0 in Drapes/blinds None 2 W 1 Vinyl Low-E Double Yes 0.36 0.31 N 4.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds None 3 W 1 Vinyl Low-E Double Yes 0.36 0.31 N 54.0 ft' 2 ft 0 in 2 ft 0 in Drapes/blinds None 4 W 2 Vinyl Low-E Double Yes 0.36 0.31 N 7.0 ft2 4 ft 0 in 2 ft 0 in Drapes/blinds None 5 W 2 Vinyl Low-E Double Yes 0.36 0.31 N 4.0 ft' 4 ft 0 in 2 ft 0 in Drapes/blinds None 6 W 2 Vinyl Low-E Double Yes 0.36 0.31 N 10.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds None 7 s 3 Vinyl Low-E Double Yes 0.36 0.31 N 6.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds None 8 s 4 Vinyl Low-E Double Yes 0.36 0.31 N 12.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 9 s 4 Vinyl Low-E Double Yes 0.36 0.31 N 30.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 10 s 4 Vinyl Low-E Double Yes 0.36 0.31 N 12.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds None 11 E 5 Vinyl Low-E Double Yes 0.36 0.31 N 30.0 ft' 2 ft 0 in 2 ft 0 in Drapes/blinds None 12 E 6 Vinyl Low-E Double Yes 0.36 0.31 N 82.0 ft' 7 ft 0 in 2 ft 0 in Drapes/blinds None GARAGE ✓ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 596 ft2 596 ft' 72 ft 9 ft 1 3/28/2018 2:42 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2027.6 111.31 209.33 .4286 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump! Split HSPF:8.5 47.5 kBtuihr 1 sys#1 COOLING SYSTEM _V— # System Type Subtype _ Efficiency Capacity Air Flow _ SHR Block Ducts 1 Central Unit/ Split SEER:15 47.5 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM 1 _ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 55 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS V ---Supply---- --Return-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 296 ft2 Attic 90 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Mar May ri:pdr., riTilll X Au n Se Oct Nov Dec Heating 'X)Jan Hm. ;X�Mar 1A4r, f i MaAuSe [ A Oct [X1 Nov )q Dec Venting Jan Feb X Mar Apr [ MayJun Jul Aug Sep [X Oct [X Nov Dec 3/28/2018 2:42 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 J FORM R405-2017 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 66 3/28/2018 2:42 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. , Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a. Frame-Wood,Exterior R=19.0 2709.80 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=19.0 252.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=19.0 946.00 ft2 6. Conditioned floor area(ft2) 1931 b.N/A R= ft2 c.N/A R= ft2 7. Windows** Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.36 267.51 ft2 a.Sup:Attic,Ret:Attic,AH:Main 6 296 SHGC: SHGC=0.31 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 47.5 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 47.5 HSPF:8.50 Area Weighted Average Overhang Depth: 3.185 ft. Area Weighted Average SHGC: 0.310 8. Floor Types Insulation Area 14. Hot water systems Cap:55 gallons a.Floor over Garage R=19.0 596.00 ft2 a. Electric EF:0.95 b.Slab-On-Grade Edge Insulation R=0.0 266.00 ft2 b. Conservation features c.other(see details) R= 104.00 ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building "• 01.E ST • ` 0� . . ... 9TH' .: Construction through the above energy saving features which will be installed (or exceeded) ,.-y . ; p�•.• in this home before final in •-..tion. Otherwise, a new EPL Display Card will be completed .'y'c;;.;„ `- , 3s .r' based on installed Code o• pliant features. ' 'll,, , _ yt:" " �.=• Builder Signature: Date: /,Al I.'� t - . �. % Address of New Home: �D.r 4/11// e,V ,j'TCity/FL Z'I�r�,v7) ��,Qr„v G' ._ p •' Xt 3_5D` *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/28/2018 2:42 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 1 *� 2017-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 1931 Right Builder Name: Street: Permit Office: City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Jacksonville COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind uioing and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 3/28/2018 2:43 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: 1931 Right Builder Name: Street: Permit Office: City,State,Zip: Atlantic Beach, FL, Permit Number: Design Location: FL,Jacksonville Jurisdiction: Cond.Floor Area:: 1931 sq.ft. Cond.Volume: 17379 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: Single or Multi Point Test Data Required ACH(50)from HOUSE PRESSURE FLOW: - FORM R405-2017 : 1 -- --- Pa cfm 2 Pa cfm Tested ACH(50) * 3 Pa cfm *Tested leakage must be less than or equal to the 4 Pa cfm required ACH(50)shown on Form R405-2017 for 5 Pa cfm this building. If the tested ACH(50) is less than _ the building must have a mechanical ventilation 6 Pa cfm system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Testing shall be conducted by either ;.0".011E ,qT .. performance results demonstrate compliance individuals as defined in Section : ti „_- ,00+'••. with Florida Energy Code requirements in 553.993(5)or(7), Florida Statutes or ro`/p, �' e individuals licensed as set forth in ++n,+,_ _. ` ,� O accordance with Section R402.4.1.2. Section 489.105(3)(f), (g), or(i)or an i approved third party. A written report of ‘0, ti; the results of the test shall be signed * f; r SIGNATURE: by the third party conducting the test `= provided '•�'CDOv and to the code official. PRINTED NAME: BUILDING OFFICIAL: DATE: -. -- — DATE: 3/28/2018 2:43 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Permit Number: Atlantic Beach, FL, MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory).The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 InstallatlonThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. 6. Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air IeakagdMndows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or MMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 3/28/2018 2:43 PM EnergyGaugee USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 3/28/2018 2:43 PM EnergyGauger&USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5 a M MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.T.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUN (CFM) (CFM/WATT) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI: 1 cfm=28.3 Umin. a. When tested in accordance with HVI Standard 916 3/28/2018 2:43 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that Its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oll-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 3/28/2018 2:43 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatorylie energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory)Fuel gas lighting systems shall not have continuously buming pilot lights. 3/28/2018 2:43 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 5 of 5 r ' Manual S Compliance Report ort Job: Lot 106 AT wrightsoftDate: 3-27-2018 Entire House By: Florida Air Service & Engineering 150 Hilden Road 308,Ponta Vedra,P 32081 Phone:904-823-9696 Web:WWW NORTHFLORIDAAIR.COM Project Information For: Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 32958 Btuh Entering coil DB: 76.8°F Outdoor design WB: 77.0°F Latent gain: 5834 Btuh Entering coil WB: 63.7°F Indoor design DB: 75.0°F Total gain: 38792 Btuh Indoor RH: 50% Estimated airflow: 1400 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC548A00300+FX4DNB049L Actual airflow: 1400 cfm Sensible capacity: 36556 Btuh 111%of load Latent capacity: 7781 Btuh 133%of load Total capacity: 44337 Btuh 114%of load SHR: 82% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 39431 Btuh Entering coil DB: 68.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC548A00300+FX4DNB049L Actual airflow: 1600 cfm Output capacity: 37503 Btuh 95%of load Capacity balance: 29 °F Supplemental heat required: 1928 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1600 cfm Output capacity: 7.1 kW 62%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. 2018-Mar-29 12:14:11 wtfto!'t• Right-Suite®Universal 2018 18.0.11 RSU09479 Page 1 Altk ...Iigan\Ahern Townhomes\Lot 4A\1931 Right End.rup Calc=MJ8 Front Door faces: W - wrightsoft Project Summary Job: Lot 108 AT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponta Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Notes: Lot 10B Ahern Townhomes Desi•n Information Weather: Jacksonville/Intnl., FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 Moisture difference 50 gr/ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 32859 Btuh Structure 27465 Btuh Ducts 6572 Btuh Ducts 5493 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Pi in Btuh Equipment load 39431 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 32958 Btuh Method Simplified Latent CoolingEquipment Construction quality Average Load Sizing Fireplaces 0 Structure 2931 Btuh Ducts 2904 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1931 1931 Equipment latent load 5834 Btuh Volume(ft3) 22206 22206 Air changes/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 38792 Btuh Equiv.AVF(cfm) 141 74 Req.total capacity at 0.70 SHR 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC548A00300 Cond 25HBC548A00300 AHRI ref 9155626 Coil FX4DNB049L AHRI ref 9155626 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 33250 Btuh Heating output 45500 Btu h @ 47°F Latent cooling 14250 Btuh Temperature rise 26 °F Total cooling 47500 Btuh Actual air flow 1600 cfm Actual air flow 1400 cfm Air flow factor 0.041 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.25 in H2O Static pressure 0.25 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=29°F Backup: Input=7 kW, Output=24267 Btuh, 100 AFUE Bold/Italic values have been manually overridden �j� Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. "r wrbhf 2018-Mar-29 12:14:11 Right-Suite®Universal 2018 18.0.11 RSU09479 Page 1 ...IiganiAhem Townhomes\Lot 4A11931 Right End.rup Calc=MJ8 Front Door faces: W wrlghtsott Right-J® Worksheet Job: Lot 10B AT Entire House Date: 3-27-2018 Florida Air Service & Engineering By: 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Entire House 2 Exposed wall Laundry 396.0 ft 20.0 ft 3 Room height 9.4 ft 9.0 ft heat/cool 4 Room dimensions 9.0 x 11.0 ft 5 Room area 3047.0 ft2 99.0 ft' I I I I t I Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') Load number (Bt uh/ft2-°F (Btuh/ft2) I or perimeter (ft) (Btuh) or perimeter I1 (ft) ( (Btuh) I Heat I Cool I Gross N/P/S Heat I Cool I Gross I N/P/S I Heel I Cool I 6 W 12A-Osw 0.240 n 9.00 7.25 408 408 3672 2957 0 0 0 0 . W 12E-Osw 0.068 n 1.56 0.88 578 578 900 506 81 81 207 116 12A-Osw 0.240 a 9.00 7.26 198 168 1512 1218 0 0 0 0 1D-c2ow 0.570 a 21.38 52.90 30 0 641 1587 0 0 0 0 11 ylL12E-Osw 0.088 e 1.48 0.82 670 588 858 483 0 0 0 0 -G 1D-c2owd 0.570 e 21.38 33.46 82 46 1744 2730 0 0 0 0 12A-Osw 0.240 s 9.00 7.25 121 115 1035 834 0 0 0 0 1D-c2ow 0.570 s 21.38 22.23 6 0 128 133 0 0 0 0 12E-Osw 0.068 s 1.83 1.03 853 799 1464 824 0 0 0 0 1D-c2ow 0.570 s 21.38 22.23 54 0 1154 1200 0 0 0 0 W 12A-Osw 0.240 w 9.00 7.25 489 408 3668 2954 0 0 0 0 -C' 10B-w 0.600 w 22.50 24.68 16 3 370 406 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 20.18 7 7 150 141 0 0 0 0 -C 1D-c2ow 0.570 w 21.38 52.90 4 0 86 212 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 52.90 54 0 1154 2857 0 0 0 0 h12E-Osw 0.068 w 2.55 1.43 379 341 870 489 99 95 242 136 1D-c2ow 0,570 w 21.38 30.00 4 3 86 120 4 3 86 120 1D-c2ow 0.570 w 21.38 52.90 10 0 214 529 0 0 0 0 1100 0.390 w 14.62 11.78 24 24 351 283 0 0 0 0 Ij 12C-Osw 0.091 - 3.41 1.39 252 233 794 324 99 99 338 138 �-D 11D0 0.390 n 14.62 11.78 19 19 282 227 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 1210 1210 2314 1833 0 0 0 0 F 19C-19cscp 0.049 - 0.64 0.30 700 700 446 212 0 0 0 0 F 22A-tpl 0.989 - 19.40 0.00 1210 164 3173 0 99 20 742 0 c)AED excursion I 6 I Envelope loss/gainI I 270651 230570 16141 5591 12 a) Infiltration 5794 1448 348 87 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Qa 230 2 460 0 0 Appliances/other 2500 500 Subtotal(lines 6 to 13) 32859 27465 1962 1146 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 32859 27465 1962 1146 15 Duct loads 20% 20% 6572 5493 20% 20% 392 229 Total room load I I I 394311 329581 I I 23551 13751 Air required(cfm) 1600 1400 96 58 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. JAS -4.- ...40-wir.v.ra- 2018-Mar-29 12:14:11 N Right-Suite®Universal 2018 18.0.11 RSU09479 Page 1 ...IigarMhern Townhomes1Lot 4A\1931 Right End.rup Calc=MJ8 Front Door faces: W "*•wHOtsoft Right-J® Worksheet Job: Lot 10B AT Entire House Date: 3-27-2018 Florida Air Service & Engineering • By: 150 Hilden Road 308,Ponta Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM I Room name 2 Exposed wall Entry Garage 3 Room height 32.0 ft 78.0 ft 9.0 ft heaVcool uncondit. 4 Room dimensions 9.0 H 5 Room area 1.0 x 189.0 ft25.0 x 28.0 ft U I 169.0 f t' 700.0 f N Ty Construction U-value Or I HTM I Area (ft') r Load I Area (ft') Load number (Btuh/fV-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) II Heat I Cool I Gross N/P/S Heat I Cool Gross I N/P/S Heat I Cool I 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 0 . W 12E-Osw 0.068 n 1.56 0.88 0 0 5 0 0 V►r 12A-Osw 0.240 e 9.00 7.25 0 0 0 220 225 0 0 l-�, 1 D-c2ow 0 0 0 0 0 0 0 0.570 a 21.38 52.90 0 0 0 0 0 0 0 0 11 y 12E-Osw 0.068 e 1.46 0.82 27 27 69 39 252 252 0 0 10-c2owd 0.570 e 21.38 33.46 0 0 0 0 0 0 0 0 VLG 12A-Osw 0.240 s 9.00 7.25 0 0 0 0 0 1D-c2ow 0.570 s 21.38 22.23 0 0 0 0 0 0 0 VN 12E-Osw 0.068 s 1.83 1.03 81 81 207 116 225 225 0 0 _ ( 1D-c2ow 0.570 a 21.38 22.23 0 0 0 0 0 Vi 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 0 0 0 -G 10B-w 0.600 w 22.50 24,68 0 0 0 0 0 0 0 0 ---G 1D-c2ow 0.570 w 21.38 20.18 0 -G 1 D-c2ow 0 0 0 0 0 0 0 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 -C 1 D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 12E-0sw 0.068 w 2.55 1.43 180 156 398 224 0 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 D 1100 0 0 0 0 0 0 0 0.390 w 14.62 11.78 24 24 351 283 0 0 0 R 12C-0sw 0.091 - 3.41 1,39 153 134 456 186 0 0 0 0 �-D 1100 0.390 n 14.82 11.78 19 19 282 227 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 0 0 0 0 0 0 F 19C-19cscp 0.049 - 0.84 0.30 0 0 0 0 F 22A-tol 0 0 0 0 0 0 0.989 - 19.40 0.00 169 32 1187 0 700 78 0 0 6I c)AED excursion Envelope loss/gain I + 137 0 ( 29491 938) I 0I 01 12 a) Infiltration b) Room ventilation 5570 1300 0 0 0 0 13 Internal gains: Occupants(§ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 3507 1077 0 0 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 3507 1077 0 0 20% 20% 701 215 0% 0% 0 0 Alr omequi d load I I I 1711 12551 I I OI 0 0 O Calculations aoaroved by ACCA to meet all requirements of Manual J 8th Ed. w'tillt~ �ilk-Iltss 2018-Mar-2912:14:11 Right-Suite®Universel 2018 18.0.11 RSU09479 IiganlAhem TownhomeslLot 4A11931 Right End.rup Calc=MJ8 Front Door faces: W Page 2 #wrlghtsof Right-J® Worksheet Job: Lot 10B AT Entire House Date: 3-27-2018 Florida Air Service & Engineering By: 150 Hilden Road 308,Ponte Vedre,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name 2 Exposed wall Master M WIC 3 Room height 32.0 ft 19.0 ft 4 Room dimensions 10.0 ft heat/cool 10.0 ft heat/cool 5 Room area 260.0 f t 1.0 x 260.0 ft 7.0 x 12.0 ft t I I ' 84.0 ft I Ty Construction U-value Or I HTM I Area (ft') i Load I Area (f t') I Load number (Btuh/ft'-°F (Btuhlft') or perimeter (ft) I (Btuh) or perimeter (ft) (Btuh) IHeat I Cool I Gross I N/P/S I Heat I Cool 1 Gross I N/P/S I Heat I Cool 6 W 12A-Osw 0.240 n 9.00{ 7,25 140 140 1260 1015 0 0 0 W 12E-Osw 0.068 n 1.56 0.88 0 0 0 0 12A-Osw 7 0 0 0 0 0,240 a 9.00 7.25 180 150 1350 1087 0 0 0 0 1D-c2ow 0.570 e 21.38 52.90 30 0 641 1587 0 0 11 14l 12E-0sw 0.068 e 1.46 0.82 0 0 0 0 L___G 1D-c2owd0 0 120 120 300 172 0.570 e 21.38 33.46 0 0 0 0 0 0 VII 12A-Osw 0.240 a 9.00 7.25 0 0 0 0 0 0 0 0 L.. G 1D-c2ow 0.570 a 21.38 22.23 0 0 0 0 0 0 0 12E-Osw 0.068 s 1.83 1.03 0 0 0 0 70 64 163 92 1 D-c2ow 0.570 s 21.38 22.23 0 0 0 0 6 0 128 133 V/ 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 -G 10B-w 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 D 1100 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 R 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 150 150 287 227 84 84 161 127 F 19C-19cscp 0.049 - 0.64 0.30 188 188 120 57 30 30 19 9 F 22A-tol 0.989 - 19.40 0.00 72 9 329 0 54 12 453 0 61 c)AED excursion 1 35 Envelope toss/gaini 39871 29 40021 1 1 12301 499 12 a) Infiltration b) Room ventilation 6190 1500 368 92 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4606 4616 1598 591 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 4606 4616 1598 591 15 Duct loads 20% 20% 921 923 20% 20% 320 118 II Airtarequirred(cfm) I I I 5527 5542351 I I 1918 7301 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w it" fs 2018-Mar-2912:14:11 Rig ht-Su ilea Univ ersal 2018 18.0.11 RSU09479Page 3 IlganWhem TownhomeslLot 4A11931 Right End.rup Calc=MJ8 Front Door faces: W • 4-wrightsoft Right-J® Worksheet Job: Lot 10B AT Entire House Date: 3-27-2018 Florida Air Service & Engineering By: 150 Hilden Road 308,Pante Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name M Bath 2 Exposed wall 12.0 ft Powder 3 Room height 9.0 ft heat/cool 10.0 ft O ft 4 Room dimensions heat/cool 5 Room area 119.0 ft2 1 0 x 119.0 ft 25.0 f t°5.0 x 5.0 ft I I Ty Construction U-value Or I HTM Areaft' Area : number (Bt uh/ft2-`F (Bt uh/ft') }I or perimeter (ft) (Btuh) iI or (ft) (Bt perimeter Load I IHeat I Cool I Gross N/P/S Heat I Cool I Gross I N/P/S HeatIh)Cool I 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 n 1.56 0.88 0 0 0 0 0 0 0 0 12A-Osw 0.240 e 9.00 7.25 0 0 0 0 0 0 0 0 1D-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 11 /L- 12E-0sw 0.068 e 1.46 0.82 0 0 0 0 0 0 0 0 G 1D-c2owd 0.570 e 21.38 33.46 0 0 0 0 0 0 0 0 W 12A-Osw 0.240 s 9.00 7.25 0 0 0 0 0 0 0 0 I�� 1D-c2ow 0.570 a 21.38 22.23 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 a 1.83 1.03 108 102 260 146 0 0 0 0 L-C; 1D-c2ow 0.570 a 21.38 22.23 6 0 128 133 0 0 0 0 W 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 -G 10B-w 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 ---C 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 ----C 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 12E-Osw1.0 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 1 D c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 11 D0 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 9LD 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 12 12 23 18 0 0 0 0 F 19C-19cscp 0.049 - 0.64 0.30 95 95 61 29 25 25 16 8 F 22A-tol 0.989 - 19.40 0.00 24 2 90 0 0 0 0 0 132-01 1 6 c)AEDexcursionps/ n ( I 1 5621 1 i 161 71 12 a) Infiltration b) Room ventilation 2090 520 0 0 0 0 13 Internal gains: Occupants(4230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 771 372 16 7 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 14 Subtotal 7710 372 116 70 15 Duct loads 20% 20% 154 74 20% 20% 3 1 1 Ar relqui ed(cd) 1 I 9381 4491 I I 191 0( Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Pie- w-"tl7sasatnt 2016-Mar-2912:14:11 Right-Suite®Universal201818.0,11 RSU09479 Page 4 ...ligaMAhem Townhomes'Lot 4A11931 Right End.rup Calc=MJ8 Front Door faces: W *41-iwrightsott' Right-J® Worksheet Job: Lot 10B AT Entire House Date: 3-27-2018 Florida Air Service & Engineering By: 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Kitchen 2 Exposed wall Dining 11.0 ft 10.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 11.0 x 14.0 ft 10.0 x 12.0 ft 154.0 f 12 5 Room area 120.0 ft2 i 1 I I r Ty Construction U-value i Or I HTM I Area (ft2) I Load I Area (1t2) Load number (Bt uh/ft2-°F (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat f Cool f Gross I N/P/S I Heat I Cool I Gross I N/P/S Heat I Cool I 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 0 0 0 0 . W 12E-Osw 0.068 n 1.56 0.88 110 110 281 158 0 0 0 0 Vy 12A-Osw 0.240 e 9.00 7.25 0 0 0 0 0 0 0 0 �< 1D-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 11 VLG 12E-0sw 0.068 e 1.46 0.82 0 0 0 0 0 0 0 0 1D-c2owd 0.570 a 21.38 33.46 0 0 0 0 0 0 0 0 W 12A-Osw 0.240 s 9.00 7.25 0 0 0 0 0 0 0 0 L-G 1D-c2ow 0.570 s 21.38 22.23 0 0 0 0 0 0 0 0 W 12E-0sw 0.068 s 1.83 1.03 0 0 0 0 100 85 217 122 �� 1D-c2ow 0.570 s 21.38 22.23 0 0 0 0 15 0 321 333 W 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 -f 10B-w 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21,38 20.18 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 ---C 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 O 1100 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 q 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 -D 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 11 11 21 17 0 0 0 0 F 19C-19cscp 0.049 - 0.64 0.30 154 154 98 47 100 100 84 30 F 22A-tpl 0.989 - 19.40 0.00 0 0 0 0 20 2 62 0 6 I c)AED excursion -256 I 29Envelope loss/gain 400 -35 I 663 5151 12 a) Infiltration 213 53 194 48 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants t t 230 0 0 0 0 Appliances/other 2000 0 Subtotal(lines 6 to 13) 613 2018 856 563 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 613 2018 856 563 15 Duct loads 20% 20% 123 404 20% 20% 171 113 I ToAir talrequirroom lo(cadfm) I I 1 7301 21031 1 1 1028 676 I ed Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. AttAlt wrlp~��� 2018-Mar-2912:14:11 RigUniversal201818.0.11 RSU09479 Pages ...Ilgan\Ahem Townhames\Lot 4A\1931 Right End.rup Calc=MJ8 Front Door faces: W r 14¶Nrigihtsott Right-J® Worksheet Job: Lot 10B AT Entire House Date: 3-27-2018 Florida Air Service & Engineering By: 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Mid Stairs 2 Exposed wall Living 19.0 ft 3 Room height 41.0 ft 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 5 Room area 80.0 ft'80 x 10.0 ft 360.0 ft'1.0 x 360.0 ft I I Ty Construction U-value I Or I HTM I Area ft I z ( ) Load Area ft Load I number (Btuh/ft'-°F (Btuhlft') + or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) I Heat I Cool I Gross N/P/S Heat I Cool I Gross I N/P/S Heat Cool 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 160 160 1440 1160 . W 12E-Osw 0.068 n 1.56 0.88 0 0 0 0 0 0 0 0 12A-Osw 0.240 e 9.00 7.25 0 0 0 0 0 0 0 0 1D-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 11 w 12E-Osw 0.068 e 1.46 0.82 10 10 26 14 0 0 0 0 '--G 1D-c2owd 0.570 e 21.38 33.46 0 0 0 0 0 0 0 0 12A-Osw 0.240 8 9.00 7.25 0 0 0 0 40 40 360 290 1D-c2ow 0.570 s 21.38 22.23 0 0 0 0 0 0 0 0 1N 12E-Osw 0.068 s 1.83 1.03 80 65 166 93 0 0 0 0 �-G 1D-c2ow 0.570 s 21.38 22.23 15 0 321 333 0 0 0 0 VJ 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 210 156 1404 1131 -G 1OB-w 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 --G 1D-c2ow 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 54 0 1154 2857 12E-Osw 0.068 w 2.55 1.43 100 90 230 129 0 0 0 0 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 10 0 214 529 0 0 0 0 1100 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 0 0 0 0 76 76 145 115 F 19C-19cscp 0.049 - 0.64 0.30 0 0 0 0 108 108 69 33 F 22A-tol 0.989 - 19.40 0.00 0 0 0 0 64 7 270 0 6 c)AED excursion -16 I 860 I Envelope loss/gain 9551 1083 4843 6445 12 a) Infiltration 368 92 793 198 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1323 1175 5636 6643 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 0 0 0 0 14 Subtotal 1323 1175 5636 6643 15 Duct loads 20% 20% 265 235 20% 20% 1127 1329 Air rel quired(dm)room load Alt 1 I I 1587 1410 if I I 6763 7972 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _0i4F. ,.... t'�att 2018-Mar-2912:14:11 Right-Su its®Universal 2018 18.0.11 RSU09479 ...ligan\Ahem Townhomes\Lot 4A11931 Right End.rup Calc=MJ8 Front Door faces: W Page 6 urightso t Right-J® Worksheet Job: Lot 10B AT Entire House Date: 3-27-2018 Florida Air Service & Engineering By: 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9698 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Loft 2 Exposed wall Mech 32.0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 54 Room m area232.0 }1, dimensions 1.0 x 232.0 ft 6.0 x 3.0 ft 18.0 18 1 r 1 i Ty Construction U-value Or I HTM I Area (ft') Load Area (ft') Load number (Btuh/ft-8F (Btuh/ft) or perimeter (ft) fI (Btuh) I or perimeter (ft) (Btuh) IHeat I Cool Gross N/P/S Heat I Cool I Gross I N/P/S Heat I Cool I 6 W 12A-0sw 0.240 n 9.00 7.25 0 0 0 0 0 0 0 0 . W 12E-Osw 0.068 n 1.56 0.88 0 0 0 0 0 0 0 0 12A-Osw 0.240 e 9.00 7.25 18 18 162 130 0 0 0 0 1D-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 11vr_G12E-Osw 0.068 e 1.46 0.82 0 0 0 0 0 0 0 0 1 D-c2owd 0.570 e 21.38 33.46 0 0 0 0 0 0 0 0 W 12A-Osw 0.240 s 9.00 7.25 81 75 675 544 0 0 0 0 �-C 1D-c2ow 0.570 s 21.38 22.23 8 0 128 133 0 0 0 0 12E-Osw 0.068 s 1.83 1.03 0 0 0 0 0 0 0 0 1D-c2ow 0.570 s 21.38 22.23 0 0 0 0 0 0 0 0 124-0swlok 0.240 w 9.00 7.25 189 169 1517 1222 0 0 0 0 108-w 1D-c2ow 0.600 w 22.50 24.68 16 3 370 406 0 0 0 0 0 0.570 w 21.38 20.18 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 4 0 86 212 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-tow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 11D0 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 R 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 �-D 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 232 232 444 351 18 18 34 27 F 19C-19cscp 0.049 - 0.64 0.30 0 0 0 0 0 0 0 0 F 22A-tol 0.989 - 19.40 0.00 8 1 41 0 0 0 0 0 D excursion -70 6 I Envelope loss/gain I 1 3422 29281 I 34+ 241 12 a) Infiltration 557 139 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 8 to 13) 3980 3087 34 24 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 17 12 -34 -24 14 Subtotal 3997 3079 0 0 15 Duct loads 20% 20% 799 616 20% 20% 0 0 Total room load I I 47981 36951 I I 0I 0I Air required(cfm) J 195 157 0 f 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wartpINItararvw- 2018-Mar-29 12:14:11 Right-Suite®Universal 2018 18.0.11 RSU09479 Page 7 ...ligan\Ahern Townhomes\Lot 4,411931 Right End.rup Calc=MJ8 Front Door faces: W ` I- Wvrigltot• Right-.J Worksheet Job: Lot 106 AT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponta Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name WIC 1 Bed 1 2 Exposed wall 6.0 ft 30.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 6.0 x 7.0 ft 15.0 x 15.0 ft 5 Room area 42.0 ft= 225.0 ft' I 1 1 I 1 1 TyConstruction U-value Or HTM Area ft' Load Area ft' Load ( ) ( ) number (Btuh/f l'-°F (Btuh/fN) or perimeter (ft) (Btuh) or perimeter (ft) I (Btuh) Heat I Cool I Gross I N/P/S I Heat Cool Gross N/P/S I Heat I Cool 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 0 0 0 0 • W 12E-Osw 0.068 n 1.56 0.88 0 0 0 0 0 0 0 0 Vel 12A-Osw 0.240 6 9.00 7.25 0 0 0 0 0 0 0 0 C- 10-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 11 W 12E-Osw 0.068 e 1.48 0.82 0 0 0 0 135 94 240 135 G 10-c2owd 0.570 e 21.38 33.46 0 0 0 0 41 23 872 1365 Wy 12A-Osw 0.240 s 9.00 7.25 0 0 0 0 0 0 0 • 0 �-G 1D-c2ow 0.570 s 21.38 22.23 0 0 0 0 0 0 0 0 t_ 12E-Osw 0.068 s 1.83 1.03 54 54 138 77 135 123 314 176 G 1D-c2ow 0.570 s 21.38 22.23 0 0 0 0 12 0 257 267 W 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 -G 10B-w 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 -0 1D-c2ow 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 -0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 VVW 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 I( � 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 D 1100 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 FLo12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 42 42 80 64 225 225 430 341 F 19C-19cscp 0.049 - 0.64 0.30 0 0 0 0 0 0 0 0 F 22A-tol 0.989 - 19.40 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion n 218 I 19 I I 272 Envelope loss/gai122 2113 2012 12 a) Infiltration 105 26 523 131 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 323 148 2635 2143 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 11 8 6 4 14 Subtotal 334 156 2641 2147 15 Duct loads 20% 20% 67 31 20% 20% 528 429 Total room load 401 188 3169 2576 Air required(dm) I I 16I BI I I 129 109 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -.4,-. wri ilaihollt- 2018-Mar-2912:14:11 ft*. - Right-Suite®Universal 2018 18.0.11 RSU09479 Page 8 ...Iigan1Ahem Townhomes\Lot 4A\1931 Right End.rup Cato=MJ8 Front Door faces: W r 4 wrlghtsoft' Right-J® Worksheet Job: Lot 1013 AT Entire House Date: 3-27-2018 By; Florida Air Service & Engineering 150 Hilden Road 308,Ponta Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Bed 2 Bath 1 2 Exposed wall 32.0 ft 22.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 240.0 ft 12.0 x 10.0 ft 5 Room area 240.0 ft' 120.0 ft' r t Ty Construction U-value Or HTM Area (ft.) Load Area (ft2) Load I i I number (Btuhlft2-°F I (Btuh/f 12) I or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) Heat I Cool Gross I N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 6 W 12A-Osw 0.240 n 9.007.25 0 0 0 0 108 108 972 783 W 12E-Osw 0.068 n 1.56 0.88 162 162 413 232 0 0 0 0 Vy 12A-Osw 0.240 e 9.00 7.25 0 0 0 0 0 0 0 0 L-C 1D-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 11 Vll 12E-Osw 0.068 e 1.46 0.82 126 85 217 122 0 0 0 0 Lam, 1D-c2owd 0.570 e 21.38 33.46 41 23 872 1365 0 0 0 0 1___G12A-Osw 0.240 s 9.00 7.25 0 0 0 0 0 0 0 0 1D-c2ow 0.570 s 21.38 22.23 0 0 0 0 0 0 0 0 1/LG 12E-Osw 0.068 s 1.83 1.03 0 0 0 0 0 0 0 0 1D-c2ow 0.570 s 21.38 22.23 0 0 0 0 0 0 0 0 W 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 90 83 747 602 -G 10B-w 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 -G 1D-clow 0.570 w 21.38 20.18 0 0 0 0 7 7 150 141 -C 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 -G 1 D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 h 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 1100 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 9 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 L-D 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 240 240 459 364 120 120 229 182 F 19C-19cscp 0.049 - 0.64 0.30 0 0 0 0 0 0 0 0 F 22A-tol 0.989 - 19.40 0.00 0 0 0 0 0 0 0 0 I 6 I cD excursion -251 99 Envelope loss/gain I 1961 18331 2098 18061 12 a) Infiltration 557 139 383 96 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 8 to 13) 2519 1972 2481 1902 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2519 1972 2481 1902 15 Duct loads 20% 20% 504 394 20% 20% 496 380 I I TotalAirrequireroom load I I I 30231 23861 I I 29781 22821 123 101 121 97 d(cf Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrb latesmott- 2018-Mar-29 12:14:11 Ji. ---- Right-Suite®Universal 2018 18.0.11 RSU09479 Page9 I�Z�► ...Ilgan\Ahern Townhomes\Lot 4A\1931 Right End.rup Calc=MJ8 Front Door faces: W N • 0 1st Floor OUN Rta� ❖ 10 " 10 " Laundr •: � Garage • • . � m Entr! Sup Riser Ret Riser X16 " Or14 " Job#: Lot 10B AT Florida Air Service & Engineering Scale: 1 :68 Performed for: Page 1 150 Hilden Road 308 RightSuite®Universal 2018 Ponte Vedra,Fl 32081 18.0.11 RSU09479 Phone:904-823-9696 2018-Mar-29 12:14:36 WWW.NORTHFLORIDAAIR.COM ...nhomes\Lot 4A\1931 Right End.rup N Aso 2nd Floor out, R,,,, 10 " Kitchei • 339 cf 10 " 235 EdirAStel Livin. i.iii - 103 cfm — 8 " • ■1f 1 ' 1x20 4 " z64 4 " 16 " 1017 cfm 004 1 cfm Sup Ris 11iet Riser `powder 38 38 cfm �� 78 cfm cfm '' 16 " 14 " Dininc M WIC 42 cfm M Batt Mid Stair 4/II. $111111111=1111Miiil il fl 11 Job #: Lot 10B AT Florida Air Service & EngineeringScale: 1 : 68 Performed for: Page 2 150 Hilden Road 308 Righ tSuite®Universal 2018 Ponte Vedra,Fl 32081 18.0.11 RSU09479 Phone:904-823-9696 2018-Mar-29 12:14:36 WWW.NORTHFLORIDAAIR.COM ...nhomes\Lot 4A\1931 Right End.rup « Ni► /1 , 3rd Floor Sup Riser a(10 Bath 123 cflged 2 1,1.4 121 cfm • • '18x20 ■ 195 41r 8x20 14 " 129 cfm L Lof 44583 'ser ' - 'iser � '• X14 I Bed 1 1 WIC ' • cm taEl 4 �1 Job#: Lot 10B ATFlorida Air Service & Engineering Scale: 1 :68 Performed for: Page 3 150 Hilden Road 308 RightSuitee Universal 2018 Ponte Vedra,Fl 32081 18.0.11 RSU09479 Phone:904-623-9696 2018-Mar-29 12:14:36 WWW.NORTHFLORIDAAIR.COM ...nhomes\Lot 4A\1931 Right End.rup Duct System SummaryJob: Lot 10BAT - ' wrightsoft yDate: 3-27-2018 Entire House By: Florida Air Service & Engineering 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Heating Cooling External static pressure 0.25 in H2O 0.25 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.25 in H2O 0.25 in H2O Supply/return available pressure 0.178/0.072 in H2O 0.178/0.072 in H2O Lowest friction rate 0.100 in/100ft 0.100 in/100ft Actual air flow 1600 cfm 1400 cfm Total effective length(TEL) 292 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk Bath 1 h 2978 121 97 0.100 6.0 Ox 0 VIFx 15.8 90.0 st2 Bed 1 h 3169 129 109 0.100 8.0 Ox 0 VIFx 18.8 90.0 st2 Bed 2 h 3023 123 101 0.100 8.0 Ox 0 VIFx 16.6 90.0 st2 Dining h 1028 42 29 0.100 4.0 Ox 0 VIFx 27.5 140.0 st5 Entry h 4208 171 55 0.100 7.0 Ox 0 VIFx 44.0 164.0 st4 Kitchen c 2421 30 103 0.100 6.0 Oxo VIFx 24.8 140.0 st5 Laundry h 2355 96 58 0.100 6.0 Ox 0 VIFx 30.0 154.0 st4 Living c 7972 274 339 0.100 8.0 Ox 0 VIFx 16.9 120.0 st3 Loft h 4796 195 157 0.100 7.0 Oxo VIFx 11.2 90.0 st2 M Bath h 925 38 19 0.100 4.0 Ox 0 VIFx 26.2 140.0 st5 M wlc h 1918 78 30 0.100 4.0 Ox 0 VIFx 32.6 140.0 st5 Master c 5540 224 235 0.100 8.0 Ox 0 VIFx 28.2 140.0 st5 Mid Stairs h 1587 64 60 0.100 4.0 Ox 0 VIFx 15.8 120.0 st3 Powder h 19 1 0 0.100 4.0 Ox 0 VIFx 22.0 140.0 st5 WIC 1-A h 401 16 8 0.100 4.0 Ox 0 VIFx 24.3 110.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 266 113 0.100 488 10.0 0 x 0 VinIFIx st3 st5 Peak AVF 412 416 0.100 530 12.0 0 x 0 VinIFIx st3 st3 Peak AVF 1017 928 0.100 728 16.0 0 x 0 VinlFlx st1 st1 Peak AVF 1017 928 0.100 728 16.0 0 x 0 VinIFIx st2 Peak AVF 583 472 0.100 545 14.0 0 x 0 VinIFIx Bold/Italic values have been manually overridden 4 2018-Mar-29 12:14:12 AAw.. _.. so _ Right-Suite®Universal 2018 18.0.11 RSU09479 Page 1 ...IiganWhem Townhomes\Lot 4A11931 Right End.rup Calc=MJ8 Front Door faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb5 Ox 0 1017 928 84.0 0.080 951 14.0 Ox 0 VIFx rb2 Ox 0 583 472 0 0.080 545 14.0 Ox 0 VIFx Bold/italic values have been manually overridden wr1lohtasolPt 2018-Mar-29 12:14:12 A ...... ...... Right-Suite®Universal 2018 18.0.11 RSU09479 Paget ...Iigan\Ahem Townhomes\Lot 4A\1931 Right End.rup Calc=MJ8 Front Door faces: W