1021 ATLANTIC BLVD -UNIT 12 FIRE COMMENTS �>y;l,, City of Atlantic Beach APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
800 Seminole Road ILorvm 'ZO— 000 z
FAtlantic Beach, Florida 32233-5445lJ
Phone(904)247-5826• Fax(904)247-5845 7
\. rji; 9:- E-mail: building-dept@coab.us Date routed: I 1 ( 3 I C-0
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
LticT ( (--
Property Address: I U Z k R'rt.A-&)`n0_ BLent review required Yes No
Building_)
Applicant: 1.M'�tK(•,()(72(. 1.4 acS T Planning &Zoning
Tree Administrator
Project:
1 )° G{2A02... &D L L 0 OOT Public Works
Public Utilities
aL,C)Orr\- 6 �17-i AY LD2AL-. g 0 L0 rt 0 Public Safety
ire Servicg
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. Lbenied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: Date: 1 ^rs —Z6"
TREE ADMIN. Second Review: I lApproved as revised. ❑Deni . Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
COMM 20-0002
Returned for Corrections:
The plans submitted for review have been returned for corrections. Please correct and or provide the
additional requested information to obtain plans approval. When resubmitting corrected sheets, provide a
type written itemized narrative letter responding to our comments and directing the plans reviewer to the
sheets the changes have taken place. FAILURE TO SUPPLY RESPONSE LETTER "WILL" RESULT IN
A RETURNED FOR CORRECTIONS PERMIT STATUS. Revised sheets should be clouded, clearly
showing areas were changes or corrections have occurred and re-inserted with the original set of
drawings with old sheets removed. Unbound plans will not be reviewed. If this is an electronic submission
please make sure that written narrative is submitted under correspondence along with a"complete set"
(not just the revised sheets) of electronic documents. When submitting electronic plans, each discipline
shall upload a single PDF file containing multiple sheets rather than separate PDFs for each
sheet. Please re-upload in this fashion.
1.
Life Safety Floor Plan:
The City of Jacksonville's Fire Marshal's Office requires the submittal of a Life Safety Floor Plan for
building permits for all new construction and existing building alterations in order to ascertain if occupancy
is currently code compliant and to assist fire inspector in performing Life Safety Inspections. Please
provide a Life Safety Plan to include all the following information on one page. If Life Safety Plan was
submitted and you are receiving this comment, it means that all of the required info listed below was not
included in your original submittal. It is understood that all listed items may not apply in your situation.
Required Occupant Load Calculation:
• Provide design occupant load using table 7.3.1.2 of NFPA 101 2015 edition. Area calculations should be
shown with graphic seating configurations or fixtures in order to substantiate occupant load chosen.
Exit Locations:
• Designate main entrance and all secondary exits. All required exits shall terminate at a "public way".
Access to the public way shall be accessible and must be via a stable, firm, and slip resistant conveyance
such as a concrete sidewalk with a min. 5'x5' landing and 44"walkway. Multi story buildings should
designate area of rescue with required communication means. Separation of exits using the one half
(non-sprinkled) or one third (sprinkled)the diagonal distance rule should be shown on plans.
Required Egress Capacity:
• Egress inches for means of egress components (doors, stairs, etc.)
Required measurements: (Worst case only need be shown.)
•Dead end corridors measurements.
•Common path of travel measurements.
•Total travel distance to exits.
Required separation:
•Show all fire barriers, smoke barriers, and smoke partitions. All rated walls per new directive from
building official wall detail needs to include UL listing and needs to confirm by architect or engineer as
being accurate.
Required Lock Latch details:
•Lock/Latch details: Panic Hardware, Thumb turn lock, Key Lock with indicator and required signage.
Required Electrical Stop/Disconnect Details:
•Any required Emergency stops or Shunt trips.
•Main Electrical disconnects access/location.
Required markings of means of egress:
• Exit signs to include tactile exits signage.
Required fire extinguisher Locations:
• Locations per NFPA 10.
Required Emergency lighting:
• Show emergency illumination.
Required Lightweight Truss Signage:
• Location of lightweight truss signage per FAC 69A-60.0081 (if applicable). Please see below for
clarification to requirement.
http://www.col.neUDepartments/Planning-and-Development/Docs/Building-Inspection-Division/bulletin-f-
01-09-light-weight-truss-rule.aspx
2. Key Plan:
Provide key plan of building showing adjacent occupancy type with required separation of occupancies
per 6th Edition FFPC, NFPA 101 Table 6.1.14.1.4.
( BUSINESS TO MERCANTILE ) IS 2 HR WALL
3. EXIT SIGN AND EMERGENCY LIGHT