Ahern Townhomes ZRC 02.22.2018 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
(904) 247-5800
ZONING REVIEW COMMENTS
Date: 2/22/2018
Permit #: RES17-0264, 266, 267, 268, 269, 270, 271,
273, 274, 275, 276, 288
Site Address: 301 AHERN ST
Review Status: RE#: 169737 0010
Applicant: URBAN PARTNERS CONSTRUCTION Property Owner: AHERN TH PROJECT LLC
Email: TH@URBANPARTNERSGROUP.COM Email: rjohnston.mec@gmail.com
Phone: 9042702225
9045917929
Phone: 9042195003
THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS.
Revisions may not be submitted until ALL departments have completed their respective reviews.
Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a
few correction items will not be accepted.
Correction Comments:
1. Height: Section 24-17 requires height to be measured from grade to the highest point of a building’s
roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the
overall height from grade on plans. Note that the height cannot exceed 35 feet.
2. Site Plans: The architectural and civil site plans do not match. For example: number and location of
parking along Ahern Street, driveway configuration on East Coast Drive. It is believed that the civil set is
the most current. Please revise accordingly.
3. Fencing: 6 foot fencing is shown on the north property line. Please clarify the exact location of the 6
foot fencing. Show distance to property lines where fencing stops.
4. Wall Height: The height of the walls around the A/C equipment and along the north side of the
courtyards is shown to be 5 feet 6 inches tall. It appears this measurement is from the finish floor of the
first floor. Please show the height of these walls from grade.
Informational Comments:
1. Tree Permit: Calculations for tree mitigation will be sent separately under the tree removal permit.
Zoning
Resubmittal Notes:
All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of
completely encircling the change with “clouding”. The revision shall also be identified as to the sequence of revision by
indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date
and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which
a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with
revisions shall be inserted into each set of drawings. The original sheets must be clearly marked “VOID” but are to be left
within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED
DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW.