Loading...
1021 Atlantic Blvd 953-975 Unit 12 COMM20-0002 „.,:. '--"J.1.-� COMMERCIAL PERMIT PERMIT NUMBER s'� COMM 20-0002 CITY OF ATLANTIC BEACH ISSUED: 2/3/2020 800 SEMINOLE ROAD 01111_ ATLANTIC BEACH. FL 32233 EXPIRES. 8/1/2020 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILfl,ING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. \ NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: UNIT 12 - INTERIOR 1021 ATLANTIC BLVD 953- COMMERCIAL ALTERATION BUILDOUT for BLOOM $100000.00 975 COMMERCIAL BEHAVIORAL SOLUTIONS TYPE OF REAL ESTATE i ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: I NUMBER: GROUP: 177602 0040 SECTION LAND COMPANY: ADDRESS: CITY: STATE: ZIP: DUCKWORTH CONSTRUCTION 5726 STUART AVENUE JACKSONVILLE FL 32254 OWNER: ADDRESS: CITY: STATE: ZIP: EQUITY ONE ATLANTIC NORTH MIAMI 1600 NE MIAMI GARDENS DR FL 33179 VILLAGE INC BEACH WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. I P DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $480.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $240.00 FIRE DEPARTMENT FEE 45500002080800 0 $150.00 Issued Date: 2/3/2020 1 of 2 SLAT.,„,, COMMERCIAL PERMIT PERMIT NUMBER s r ;: ` COMM20-0002 (14 ,' �� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ISSUED: 2/3/2020 vc''; 9",' ATLANTIC BEACH. FL 32233 EXPIRES: 8/1/2020 STPlfE DBPR SURCHARGE 455-0000-208-0700 0 $10.80 STATE DCA SURCHARGE 455-0000-208-0600 0 $7.20 TOTAL: $888.001 Issued Date:2/3/2020 2 of 2 rs,:vl` City of Atlantic Beach APPLICATION NUMBER .. s Building Department (To be assigned by the Building Department.) 800 Seminole Road C©rhm Z Q— v cc z- 157,,,,AirtzAtlantic Beach, Florida 32233-5445 / Phone(904)247-5826 - Fax(904)247-5845 rill �;/ E-mail: building-dept@coab.us Date routed: 1 / l 3 1 Z_© City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Ltii , Iz Property Address: I D Z ( ' 1 s-CLftNYI e Bui De ment review required Yes No Building Applicant: .M.)C wo,_TN e_,c.T Planning &Zoning ii Tree Administrator Project: 1 i CE,--12,t Q(Z e V(, L( 0 0 ( Public Works Q Public Utilities I�t,o6 ON 0 _ C--A,--k AV LORAL.- goLu t"(0h1S Public Safety ire Servic _) Review fee $r. Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 1;2 'pproved. Denied. ❑Not applicable (Circle one.) Comments: BUILDING Vi0.2.0 PLANNING &ZONING Reviewed by: Date: 01V50 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 'f "r��- Building Permit Application Updated 10/9/18 -' City of Atlantic Beach Building Department **ALL INFORMATION 15-1800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY K sw IS REQUIRED. IO 2- r Phone: (904) 247-5826 Email: Building-Dept@coab.us ��-ll 7 Job Address:,48rAtlantic Blvd, Unit 12,Atlantic Beach, Florida 32233 Permit Number: Q-CD���V ` �O�`— Legal Description _38-2S-29E 14.040 CASTRO Y FERRER GRANT PT RECD O/R 8130-2297 _RE# 177602-0040 Valuation of Work(Replacement Cost)$4/49 ea), ti Heated/Cooled SF Non-Heated/Cooled • Class of Work: ❑New ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): L Commercial ❑Residential • If an existing structure,is a fire sprinkler system installed?: ❑Yes EINo • Will tree(s)be removed in association with proposed proiect? ❑Yes(must submit separate Tree Removal Permit) ❑No Describe in detail the type of work to be performed: /5i /4 ):)f" Florida Product Approval# for multiple products use product approval form Property Owner Information ,7��, , E G✓{ 21,3 tr9�- ., C -L r Name R .e/1c-y Ce..7)e-r-S � Address L I'hC �I'UE7k,e( it .O, ,S---l-e, Ifi City C/�5c;:7 v� /f State r!/' Zip 3322 Z Phone ��c' j_5'5 -74;7.`1 E-Mail �'io�=l ladfj e./‹. 41 /Csai /.1,!%Y!9 Owner6r Ag*t(If Agent, Power of AtTorney or Agency Letter Required) ,.,e. 4i1:(C(et t , Contractor Information Name of Company Coleman Lay Group Inc.DBA Duckworth Construction Company Qualifying Agent Coleman Lay Address 844 Whitlock Avenue,Suite 200 City Jacksonville State Florida Zip 32211 Office Phone 904-783-8384 Job Site Contact Number State Certification/Registration# CBC1262908 E-Mail ColemanlavCa)dcc.to Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Insurer Southern Owners Insurance Company OR Exempt❑ Expiration Date 7/1/20 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS, POOLS,FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR—PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBT FINANCI WITH YOUR LENDER OR AN ATTORNEY BEFORE RECOR NG Y i OTICE OF COM ENCEMENT. /111.111111111., owner or Agent) ,V (Signatur• = r.ntrac o 'gned and sworn to(or affi zd) before m: t hist 3 day of Signed and sworn to(or affirmed)before me this 10 day of `\ 0�� ,707 ,by / c / v'• }7� -.3._%,...1,..., 2 ,by :jftJXltt 1�1]/T eti ;, TONIC .1 .'"+T,• l fr.of 1 (Signature of Notary) MY COMMISSION 3 GG 353178 13. e` EXPIRES:Oc bef8, 3 , yp�/,� KAREN D. HEINRICH __7_-_e!,:?:_:-._ 'rldi:, :11.1:�a:A �denNtberij (Personally Known OR 401 °' iii, ;Notary Public State of Florida [ ]Produced Identification, i [ ]Produced Identification ,4*., m :` Commission #GG 914201 Type of Identification: 1 Zc0�` Ly 7—F37_-C 4j 1,/Type of Identification: ''' t`,c My Commission Expires Yp �.n. September 17, 2023 Property Ownership Affidavit Date: December 19, 2019 , To Whom It May Concern: 4i` I, George Whetstone here by certify that I am the Owner of the property located at 997 Atlantic Boulevard, Atlantic Beach, Florida 32233 (Physical Address) Parcel# 177602-0040 and that Bloom Behavioral Solutions will be (Name of Lessee) leasing space at this location. I hereby give my consent to the commencement of construction work to be performed in the above mentioned location built in accordance with Orange Park, FL. Georgithetstone, Chief Engineer, Regency Centers, As Agent for Owner STATE OF FLORIDA Duval County The foregoing affidavit was sworn and subscribed before me this f day of (month), 020/4 (year) by �� _wAA 's pe onall) known to me or has produced as identification. 1/(}Id (Notary Signature) eV-4.46 WENDI HILL sz,,, * Commission*GG 24048$ Exr re..November 20,2022 ��6-0F F1.0** Bonded 1 am Budget Notary S.r0104 PAGE FOUR HEATING LOAD 13. DESIGN LOADS Inside db Outside alb Difference 72 - 32 = 40 14. TRANSMISSION LOSSES HEATING LOAD db Exp. Sq. Ft. Factor Temp Diff Heating Load Windows 643.5 x 1.13 x 40 = 29086 x x = 983.5 x 0.09 x 40 = 3541 Walls 456 x 0.18 x 40 = 3283 0 x 0.33 x 40 = 983.5 x 0.09 x 40 = 3541 0 x 0.33 x 40 = Roof/ 4800 x 0.09 x 40 = 17280 Ceiling x 0.05 x = x x = Floor x 0.81 x = Other x x = x x = 15. INFILTRATION db Ft3/Min Temp Diff 336 X 40 X 1.1 = 14784 16. SUBTOTAL HEATING LOAD FOR SPACE 71515 17. DUCT HEATING LOSS Loss Line 14 Factor Subtotal 0.15 X 56731 = 8510 18. VENTILATION db Ft3/Min Temp Diff 528 X 40 X 1.1 = 23232 19. HUMIDIFICATION LOAD Inside RH Desired ( ) Max ( ) Ft3/Min Btu/Hr 100 X = (water) (air) gal/day Ft3/Min X / 100 = 20. TOTAL HEATING LOAD ON EQUIPMENT (Btuh) I 103256 I (Tons) 8.60 Energy Design Systems, Inc. 11727 Brady Rd. Jacksonville, FL 32223 (904) 268-3670 PAGE THREE 10. RETURN AIR LOAD FROM LIGHTING AND ROOF NOTE: Use 40% of watts for lights recessed in a return air ceiling Incandescent X 3.4 = Flourescent X 4.1 = NOTE: Use 100% fo the roof load for return air ceilings (Roof Load) Sq. Ft. U Factor ETD* X 0.09 X = * (ETD correction based on plenum temp.) 11. TOTAL SENSIBLE LOAD ON EQUIPMENT (Btuh) = 107477 TOTAL LATENT LOAD ON EQUIPMENT (Btuh) 33217 12. TOTAL COOLING LOAD ON EQUIPMENT (Btuh) I 140693 I (Tons) 11.72 PAGE TWO 4. INTERNAL HEAT GAIN Latent a. OCCUPANTS Number Sensible Latent 48 X 200 = 9600 X = 48 X 170 = 8160 X = b. Lights & Others NOTE:Use 60% of installed watts for lights in RETURN AIR CEILING Watts Incandescnt 3185 X 3.4 = 10829 Flourescent X 3.8 = HP Motors Btuh Usg Ftr X = X = Appliances Other 5. INFILTRATION Ft3/Min db Temp Dif 224 X 22 X 1.1 = 5421 Grains Diff 224 X 49 X 0.68 = 7464 6. SUBTOTALS LOADS & SPACE LOADS 94699 15624 7. DUCT HEAT GAIN Gain Line 6 Factor Sensible 0.1 X 94699 = 8. ROOM, SPACE OR DESIGN LOAD Add Duct gain (7) to Subtotal (6) 94699 9. VENTILATION Ft3/Min db Temp Dif 528 X 22 X 1.1 = 12778 Grains Diff 528 X 49 X 0.68 = 17593 COMMERCIAL LOAD CALCULATIONS Manual N Air Conditioning Conttactors of America For: Name Bloom Behavioral Phone Address 997 Atlantic Blvd. Unit 12 City Atlantic Beach State & Zip FL By: Contractor Energy Design Systems, Inc. Phone (904) 268-3670 Address 11727 Brady Rd. City Jacksonville State & Zip FL, 32223 COOLING LOAD 1. DESIGN CONDITIONS Time of Day 3 PM Dly Range 19 Latitude 30 a.Inside db 74 RH 50 b.Outside db 94 wb 77 Grains 49 Otsid db @ 3pm 94 - TOD corr - inside db 74 Equals 20 T.D. Daily Range Factor= M 2. SOLAR RADIATION HEAT GAIN THROUGH GLASS COOLING LOAD Exposure Shading / NOTES Sq. Ft. SolrFactr GlasFactr Sensible N X 19 X 0.4 = NE X 38 X 0.4 = E X 56 X 0.4 = SE X 57 X 0.4 = S 643.5 X 48 X 0.8 = 24710 SW X 88 X 0.4 = W X 81 X 0.4 = NW X 39 X 0.4 = 3. TRANSMISSION GAINS Equiv or E xposure db Sq. Ft. U Factor Temp Diff Glass (ALL Dirs) 643.5 X 0.70 X 20 = 9009 N 910.9 X 0.33 X 20 = 6012 NE 0 X 0.33 X 24 = E 983.5 X 0.09 X 10 = 885 Walls SE 0 X 0.33 X 31 = S 456 X 0.18 X 39 = 3201 SW 0 X 0.33 X 45 = W 983.5 X 0.09 X 10 = 885 NW 0 X 0.33 X 26 = Doors 42 X 0.58 X 16 = 386 Partition X 0.05 X 20 = RA Cing X 0.09 X 20 = Roof/Clng 4800 X 0.09 X 55 = 23760 Floors X X = X X = Use Table 9a to Determine the Temp. Dif. Across an RA Ceiling PERMITTED BUILDING DATA DO NOT WRITE BELOW - OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft2): 3 Z Z Non-Habitable Space (ft2): LAND INFORMATION: Zoning District: C (' Flood Zone: /< Minimum FFE: r 5 't ACr - BUILDING INFORMATION: Construction Type: X" .4 C— Occupancy Group: Number of stories: Max. Occupancy Load: G Fire Sprinklers Required: C. CONDITIONS/COMMENTS: -eJ ►,1 S iyLy; City of Atlantic Beach APPLICATION NUMBER J1 r�- �d Building Department (To be assigned by the Building Department.) 800 Seminole Road ctorvmY Z O_ /100 Z �� s r' Atlantic Beach, Florida 32233-5445 lJ Phone(904)247-5826• Fax(904)247-5845 11 E-mail: building-dept@coab.us Date routed: I l 3 / Z-C City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM LCL 1Z Property Address: 1 C z I RLrt Bute Department review required Yes No Q Building Applicant: CM)0 tK(,UON C c T Planning &Zoning Tree Administrator Project: rG{ Qc-e_ otLc) OO T Public Works Public Utilities 1 L-C;10(Ir\.. ��-� A ( L02AL. S©LU a 0/Qs Public Safety e(F'ire Se iry�� Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ['Approved. [ benied. ['Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: 1 -IS 'Zt" TREE ADMIN. Second Review: Approved as revised. ❑Deni• .. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 COMM 20-0002 Returned for Corrections: The plans submitted for review have been returned for corrections. Please correct and or provide the additional requested information to obtain plans approval. When resubmitting corrected sheets, provide a type written itemized narrative letter responding to our comments and directing the plans reviewer to the sheets the changes have taken place. FAILURE TO SUPPLY RESPONSE LETTER "WILL" RESULT IN A RETURNED FOR CORRECTIONS PERMIT STATUS. Revised sheets should be clouded, clearly showing areas were changes or corrections have occurred and re-inserted with the original set of drawings with old sheets removed. Unbound plans will not be reviewed. If this is an electronic submission please make sure that written narrative is submitted under correspondence along with a"complete set" (not just the revised sheets) of electronic documents. When submitting electronic plans, each discipline shall upload a single PDF file containing multiple sheets rather than separate PDFs for each sheet. Please re-upload in this fashion. 1. Life Safety Floor Plan: The City of Jacksonville's Fire Marshal's Office requires the submittal of a Life Safety Floor Plan for building permits for all new construction and existing building alterations in order to ascertain if occupancy is currently code compliant and to assist fire inspector in performing Life Safety Inspections. Please provide a Life Safety Plan to include all the following information on one page. If Life Safety Plan was submitted and you are receiving this comment, it means that all of the required info listed below was not included in your original submittal. It is understood that all listed items may not apply in your situation. Required Occupant Load Calculation: • Provide design occupant load using table 7.3.1.2 of NFPA 101 2015 edition. Area calculations should be shown with graphic seating configurations or fixtures in order to substantiate occupant load chosen. Exit Locations: • Designate main entrance and all secondary exits. All required exits shall terminate at a"public way". Access to the public way shall be accessible and must be via a stable, firm, and slip resistant conveyance such as a concrete sidewalk with a min. 5'x5' landing and 44"walkway. Multi story buildings should designate area of rescue with required communication means. Separation of exits using the one half (non-sprinkled) or one third (sprinkled) the diagonal distance rule should be shown on plans. Required Egress Capacity: • Egress inches for means of egress components (doors, stairs, etc.) Required measurements: (Worst case only need be shown.) • Dead end corridors measurements. •Common path of travel measurements. •Total travel distance to exits. Required separation: •Show all fire barriers, smoke barriers, and smoke partitions. All rated walls per new directive from building official wall detail needs to include UL listing and needs to confirm by architect or engineer as being accurate. Required Lock Latch details: •Lock/Latch details: Panic Hardware, Thumb turn lock, Key Lock with indicator and required signage. Required Electrical Stop/Disconnect Details: •Any required Emergency stops or Shunt trips. • Main Electrical disconnects access/location. Required markings of means of egress: • Exit signs to include tactile exits signage. Required fire extinguisher Locations: • Locations per NFPA 10. Required Emergency lighting: •Show emergency illumination. Required Lightweight Truss Signage: •Location of lightweight truss signage per FAC 69A-60.0081 (if applicable). Please see below for clarification to requirement. http://www.coj.net/Departments/Planning-and-Development/Docs/Building-Inspection-Division/bulletin-f- 01-09-light-weiqht-truss-rule.aspx 2. Key Plan: Provide key plan of building showing adjacent occupancy type with required separation of occupancies per 6th Edition FFPC, NFPA 101 Table 6.1.14.1.4. ( BUSINESS TO MERCANTILE ) IS 2 HR WALL 3. EXIT SIGN AND EMERGENCY LIGHT Property Ownership Affidavit Date: December 19, 2019 To Whom It May Concern: 4,\ I, George Whetstone here by certify that I am the Owner of the \O $" property located at 997 Atlantic Boulevard,Atlantic Beach, Florida 32233 (Physical Address) Parcel# 177602-0040 and that Bloom Behavioral Solutions will be (Name of Lessee) leasing space at this location. I hereby give my consent to the commencement of construction work to be performed in the above mentioned location built in accordance with Orange Park, FL. 411%9_ Georgd Whetstone, Chief Engineer, Regency Centers, As Agent for Owner STATE OF FLORIDA Duval County The foregoing affidavit was sworn and subscribed before me this ( day of Z] .. (month), a /9 (year) by c�0rrtc Goik. !.• P, • • 's pe sonally known to me or has produced #c as identification. 71/A (Notary Signature) 2o� P�Bic WEND!HILL * : * Commission#GG 240468 ExE•resNovember 20,2022 r4-Op Ft°P Bonded Into Budget Notary ServICei Printing :: CR542985 Page 1 of 1 Duval County, City Of Jacksonville Jim Overton , Tax Collector 231 E.Forsyth Street Jacksonville,FL 32202 General Collection Receipt Account No:CR542985 Date: 1/15/2020 User:Dipierri,Miguel Email:DiPierri@coj.net FIRE MARSHALL FEE FOR SERVICES PROVIDED Name:BLOOM BEHAVIORA SOLUTION Address: 1021-12 ATLANTIC By Description:Plan Review fee 150.00 Comm 20-0002 TranCode I IndexCode I SubObject I GLAcct SubsidNo I UserCode' I Project I ProjectDtl Grant I GrantDtl I DocNo J Amount 701 ( FRFP159FI I 34222 I I I I I I I ( 1150.00 Total Due:$1.50.00 Jim Overton , Tax Collector General Collections Receipt City of Jacksonville, Duval County Account No:CR542985F1RE MARSHALL FEE FOR SERVICES PROVIDED Date: 1/15/2020 Name:BLOOM BEHAVIORA SOLUTION Address:1021-12 ATLANTIC By Description:Plan Review fee 150.00 Comm 20-0002 Total Due:$150.00 • https://tccr.coj.net/printing.aspx?cr=CR542985 1/15/2020 HIGHLLIGHTEIGHTERevision Request/Correction to Comments *"ALL ATION ,,,,,----4,--?,;, D IN J f \'' City of Atlantic Beach Building Department GRAY IS REQUIRED. Tlir / 800 Seminole Rd, Atlantic Beach, FL 32233 `-j"' Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#:CI�/ YVIY'Z-CD—OOOZ E Revision to Issued Permit OR Corrections to Comments Date: //Z 7/26 Project Address: /O z I fc1 t r 0 I UC) f ort- (Z 1614f c- (.., Contractor/Contact Name: Jke- e44,eberVoi Contact Phone: 01(- Y. 76,3 Email: Ct/C`{'(7174-07 66/ 7 E__Zic6 ` l 6 ._) Description of Proposed Revision/Corrections: r Recy/t e 4 C�� - Ls `` , I J cz /--� 1'G affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • W. proposed revision/corrections add additional square footage to original submittal? No ❑ Yes (additional s.f.to be added: ) • W. proposed revision/corrections add additional increase in building value to original submittal? No ❑*Yes(additional increase in building value: $ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) 1YApproved ❑ Denied ❑ Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments Depa[ment Review Required a, ' ¶ ' R,_, 1 �r,� f , , r ,,....-i Building_ ` `''-- ., - . .- �, `J..�� Planning&Zoning Re wed By Tree Administrator JAN 2 $ 2�� Public Works r� Public Utilities / ' 2 / -W Public_ ic sSafety Date ire Serv Building Department t Updated 10/17/18 .-__._.... .---- City cfMntic f .ten^Y , FL INTERIOR DESIGN 31 West Adams Street,Suite 103 • Jacksonville,FL 32202 P: 904.632.4800 I www.hotadesign.com HOTA DESIGN STUDIO 826001326 Jose Cardenas, IIDA Transmittal Principal Interior Designer 31 West Adams Street, Ste. 103 Jacksonville, Florida 32202 PROJECT NUMBER: 19043.00 : 904.632.4800 321.698.7358 DATE: JANUARY 24, 2020 TO: FOR: Jake Chamberlin Vice President Building Review Comments— Bloom Behavioral Solutions Duckworth Construction 844 Whitlock Avenue, Suite 200 Jacksonville, Florida 32211 WE ARE SENDING YOU: ❑ Attached ❑ Under Separate Cover ® Original Drawings ❑ Change Order ❑ Samples ❑ Specifications ® Prints ❑ Disk ❑ Shop Drawings ❑ Sepia ❑ Other TRANSMITTED: ❑ As Requested ® For Your Use ❑ For Approval VIA: • INTERIOR DESIGN 31 West Adams Street,Ste.103 • Jacksonville,FL 32202 P:904.632.4800 I www.hotadesign.com HOTA DESIGN STUDIO 18:26001326 MEMO DATE: January 23, 2020 TO: TBD FROM: Jose Cardenas PROJECT: Bloom Behavioral Solutions PROJECT NO: 19025.00 RE: Application No: Comm 20-0002 REMARKS: Please find responses to the plan review comments for the project referenced above... Returned for Corrections: The plans submitted for review have been returned for corrections. Please correct and or provide the additional requested information to obtain plans approval. When resubmitting corrected sheets, provide a type written itemized narrative letter responding to our comments and directing the plans reviewer to the sheets the changes have taken place. FAILURE TO SUPPLY RESPONSE LETTER"WILL" RESULT IN A RETURNED FOR CORRECTIONS PERMIT STATUS. Revised sheets should be clouded, clearly showing areas were changes or corrections have occurred and re-inserted with the original set of drawings with old sheets removed. Unbound plans will not be reviewed. If this is an electronic submission please make sure that written narrative is submitted under correspondence along with a "complete set"(not just the revised sheets) of electronic documents. When submitting electronic plans, each discipline shall upload a single PDF file containing multiple sheets rather than separate PDFs for each sheet. Please re-upload in this fashion. 1. Life Safety Floor Plan: The City of Jacksonville's Fire Marshal's Office requires the submittal of a Life Safety Floor Plan for building permits for all new construction and existing building alterations in order to ascertain if occupancy is currently code compliant and to assist fire inspector in performing Life Safety Inspections. Please provide a Life Safety Plan to include all the following information on one page. If Life Safety Plan was submitted and you are receiving this comment, it means that all of the required info listed below was not included in your original submittal. It is understood that all listed items may not apply in your situation. Please refer to G002 "Travel Distance Plane. Required Occupant Load Calculation: • Provide design occupant load using table 7.3.1.2 of NFPA 101 2015 edition. Area calculations should be shown with graphic seating configurations or fixtures in order to substantiate occupant load chosen. to Revised Building Summary, Occupants & Exits Table on Sheet G002 Exit Locations: • Designate main entrance and all secondary exits. All required exits shall terminate at a"public way". Access to the public way shall be accessible and must be via a stable, firm, and slip resistant conveyance such as a concrete sidewalk with a min. 5'x5' landing and 44"walkway. Multi story buildings should t, .::41Ar• 13er .01 rij3le-lciveri,A1 .n4:1318 :;000-0 nolle.;1,1qA 1°."0:;;= • r.4.9rnato , Ai47iNe)rt6V .nn ..artc, ..?..2.31.102.1.0.11sop;10A lentmtibt, votq 10 bnp, 32.5•rto:*;eaeV! .1c'!t.err::3:711 •;-;lc.11!.- 1,1cildue 3n6,,-4erfl +; betc,--„--ra.)1.:,,,o;_tn1-..-1.;52.5-3$f1"3:r.,- 1,zkJr.1 ,74qS flif-;35:5n ot bslee;1r,s1 •••..• 0r1lo! •;4r.141q t:ne elf '.1n.,brt.;;..-;„;-f i.4U-1*-7.1H A ii-11 1,11 Y_Hs"!13,?. j;,% ; .15;4m eviin • • •, vtiset3 eteFie ty.•:-,;,1,14,3:•-•1 84.17 AT2 Tif.45-13‘1 7.-.,*;/* T.0 4510::') • r•) t4F.te en041:)0nc; 18'11 sAarn 0 .01q edit ivsi 04.;Inn ertaig :;:ncotc,ale beeivel ecU ft.qlortYlaz e 4-inw Ql•'0E6.1flebilat9T101111bn0 19(1-1-1 ai6erie..c)1,-.1;' rrt poinisslnoo RQ1 elenie E i3:00i011 412 !'llir,v32.1-) :1'369 i01139ki. .nuiri;,;,;61 Il :3;9%.1Ee.1:5 15=snila ''ROq 01s-tec.ise finiq loo14 Vf01se Iu c.in1;-1);iti nr:.11 loon 4-; ';' I& unril::43111, Plella•ieltil oi e'ellvnoe,lz,r.1., c;ea 041T f'1.erie3es tjvr..)( r1r dfI9i niiodp,.!1:‘,. )4e wr U mkiq pnirnifatier, „te;.E. G o. brit.; 103 obcr) ;.-3 • • -(,^V Nffit ;.,_;g044 3rto no ,...oiteo-filotrli z i flEetyL,I.;,,i :tif,-.11 'aeilul.„)nt too erivi WE beteti dint 001:up..51 0r1t.Ie.) 3i;r1.1 fl ,ln.34ncr.co , • .;•; ,niuP ic n ylqqs in yam arneli bete); +:1; c. 11 :noits!tpfsl bEoJen ;%,/1,.4, 01222.tyspli celA .101t1b.s roc, -c; ikTio 01dsikjt)001Insoii:',7.;o n; es tilt*,10 gnilsee -' , • 83oi . yl/4 Htrlelix0 bsliupel ft. ,atixe Nosbr::33S8 OS bre enneltele,Mem etrinp1;%.96 11-f-17'i:15+1 flii? £ 041 I ;(11 bt 9CI ii6f12 yevti 5f1t c 1 if bioorti: F.po..1...)1i,..4 vole 111uM .yewilsw bri-;pnibnr;1 r”:n. el•ellnoD e Page 2 1/23/2020 designate area of rescue with required communication means. Separation of exits using the one half (non-sprinkled) or one third(sprinkled)the diagonal distance rule should be shown on plans. refer to exit locations identified in the"Travel Distance Plan" on Sheet G002. Required Egress Capacity: • Egress inches for means of egress components(doors, stairs, etc.) Refer to Occupancy & General Building Requirements Table of Sheet G002 Required measurements: (Worst case only need be shown.) • Dead end corridors measurements. None provided • Common path of travel measurements.45'-0" (Refer to G002 "Travel Distance Plan".) • Total travel distance to exits. 65'-0" (Refer to G002 "Travel Distance Plan".) Required separation: • Show all fire barriers, smoke barriers, and smoke partitions. All rated walls per new directive from building official wall detail needs to include UL listing and needs to confirm by architect or engineer as being accurate. Tenant separation partitions are existing. GC to confirm rating. Required Lock Latch details: • Lock/Latch details: Panic Hardware, Thumb turn lock, Key Lock with indicator and required signage. Shall provide. Existing Rear exits are equipped with Panic Hardware. Required Electrical Stop/Disconnect Details: • Any required Emergency stops or Shunt trips. Please refer to Electrical Sheets provided by GC • Main Electrical disconnects access/location. Please refer to Electrical Sheets provided by GC Required markings of means of egress: • Exit signs to include tactile exits signage. Shall provide per NFPA 101.7.10.1.3 Required fire extinguisher Locations: • Locations per NFPA 10. Shall provide Required Emergency lighting: • Show emergency illumination. Please refer to Electrical Sheets provided by GC Required Lightweight Truss Signage: Location of lightweight truss signage per FAC 69A-60.0081 (if applicable). Please see below for clarification to requirement. http://www.coi.net/Departments/Planninq-and-Development/Docs/Buildinq-Inspection-Division/bulletin-f- 01-09- light-weight-truss-rule.aspx. N/A c g(i w3r3!e,}o�:' uts K d *t . _i, >.?F ^t n } n el,s;,120110 r3 4E .�.nr; �;,nl. girl-::,. tz._,it_i�:• �U, J s:se��10 sols --,.�ftpizpt 3 . .'r :C,('I4� U _ '?:'rJ�.:.iv ick^. �:� - trr.i ?lti ' 1 i}'/it,n,-1 i_i '':^i>Itv ,.!9.-r1011'; rv.)02) }t]anseff{tt11 ??t1'iC'1 a (-"W°01 S 17;;?Fi 'in22.£E'.1tC7.': `1. ,;,9Atfl'►7tj'iF=..`?`_1)01;14 . ...`1` m19iUar`ift: c'i;''' i?3?e71,7;t.'r17.0.Q • t.,zF: S�si:fiU,"sq r?r> 'tmoO • :F1c)17 8:•3 _8 bt,iitlpe$1 •. JJ�t ? 1 :: t tt.,1 iU"'' -3r3Oitertsq '`fit,; re : F> ,i%3 tSF,'. sAt.ir iz .clt)iTik;.7 #.3tr ':1 '(t �rnitrn::of$b`'r9f1 i` t¢'•. ;)rvtgt)JU'�fi!1.`} � )13ni h911ite );10..J , 1:)0! i tl{ij til,.-ijr$i .��>� '_�?� F''`t:'1c ,t...':7�'1W:- .;;�:t-.,1 • w 1i soC ) e s?.1CAr n,.. is i,t i'I 1411/t)3FF . i;; 3 tntA11. 'i Vi ;rt•? ikfit{l: yF:,♦ • • . .. �:`.. i .i;. f''.i.:,7}�;::-r .-;� �f'?";,3.^.it3d''_ 1$.'3171 .x i_ ••1tiki • e Zp7 trrs9rr;!�_ i)h.f; bd�ittj beltyps33 #,'.... ywnegierii':3`„,,io i:-' • ;@(3cnki s2LL-3 '?t iM<v'+� eft belie ,an B<.:? ,sp)i':j h$i:iO.Cic:-ACIir OM-I -paari;i.-G2ui iiip �'dJj"f ii Y{' i*JI;S 1•'.3_) • Page 3 1/23/2020 2. Key Plan: Provide key plan of building showing adjacent occupancy type with required separation of occupancies per 6th Edition FFPC, NFPA 101 Table 6.1.14.1.4. To clarify, the adjacent occupancy types are Group"B" business. Refer to Vicinity Plan located on Sheet G001. (BUSINESS TO MERCANTILE) IS 2 HR WALL 3. EXIT SIGN AND EMERGENCY LIGHT 31 WEST ADAMS STREET, SUITE 103 • JACKSONVILLE, FLORIDA 322029 bloom behavioral solutions ATLANTIC BEACH , FLORIDA PH 904.632.4800 FAX 904.399 .5282 www.hot_a design com IB -26001326 PERMIT SET 8 NOVEMBER, 2019 INTERIOR DESIGN ROTA DESIGN STUDIO, LLC T: 904.632.4800 IB -26001326 REVIEWED FOR CODE C BEACH NCE CITY OF ATLAN SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS C Zd �,�.. DATE, �v�Z REVIEWED BY:.� .- �+ HOTA DESIGN STUDIO, LLC RL -ED Date L Cppy ISIENERAL NOTE5 I$ 5FECIICATION5 rAAAIN6 5**'�40L5 V"C I N I fit'N rAAm A I NO I NX I. ALL WORK TO COMPLY WITH APPLICABLE CODES. THE CONTRACTOR MUST COMPLY WITH THE RULES AND REGULATIONS OF 5YMBOL5 DE50RIPTION AALL DE516NATION5 DE5GRIPTION A6ENGIE5 HAVING JURISDICTION AND TO CONFORM TO ALL CITY, COUNTY, STATE AND FEDERAL CONSTRUCTION, SAFETY AND SANITARY LAWS, CODES, STATUES AND ORDINANCES. GREENBERG SHEET NO. SHEET DESCRIPTION 2. ALL FEES, TAXES, PERMITS, APPLICATIONS AND CERTIFICATES OF INSPECTION AND THE FILING OF ALL WORK WITH {� COLUMN DE5161�IATION UNRATED VINTAGE DENTAL COVER PAGE GOVERNMENTAL A6ENGIE5 TO BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR TO OBTAIN ALL PERMITS AND O WALL BARBER H C7001 INDEX, SITE INFORMATION GENERAL NOTES APPROVALS PRIOR TO COMMENCEMENT WITH THE WORK. SHOP 3. THE CONTRACTOR TO COMPLY WITH THE RULES AND REGULATIONS OF THE BUILDING OWNER AND MANAGER CONCERNING HOURS I -HOUR RATED 6002 CODE SUMMARY PLAN LOBBY- ROOM NAME WALL ID -1 DEMOLITION PLAN OF AVAILABILITY OF ELEVATOR FOR MATERIAL TRANSPORT AND DELIVERY AS WELL AS THE MANNER OF HANDLING MATERIALS, EQUIPMENT AND DEBRIS. IOO ROOM NUMBER 2 -HOUR RATED I0-2 FLOOR PLAN 4. ALL WORK SHALL BE PERFORMED BY SKILLED AND QUALIFIED WORKMEN IN ACCORDANCE WITH THE BEST PRACTICES OF THE WALL '"` ID -3 REFLECTED CEILING PLAN TRADES INVOLVED AND IN COMPLIANCE WITH BUILDING RE6ULATION5 AND/OR GOVERNMENT LAHS, 5TATUTE5 OR ORDINANGES ID -4 FLOOR FIN15H PLAN CONCERNING THE USE OF UNION LABOR. 2 -HOUR SMOKE 100 DOOR NUMBER RATED WALL ID -5 FURNITURE PLAN 5. CONTRACTOR AND SUB-GONTRAGTORS TO FIELD VERIFY ALL DIMENSIONS AND GONDITION5 SHOWN ON DOGUMENT5 AND MUST m $ NOTIFY ROTA DESIGN STUDIO, LLG OF ANY DISCREPANCIES, OMISSIONS AND/OR CONFLICTS PRIOR TO PROCEEDING WITH THE WORK. 4 -HOUR RATED I0-6 FINISH $ DOOR 56HEOULE LEGEND $ INTERIOR ELEVATIONS , , ,. _ KEY NOTES WALL 6. EACH TRADE WILL BE EXPECTED TO PROCEED IN A FASHION THAT WILL NOT DELAY OTHER TRADES. SMOKE RATED 1. THE CONTRACTOR 15 RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER THEIR JURISDICTION. I WALL � f 8. MANUFACTURED MATERIALS AND EQUIPMENT TO BE STORED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN PARTITION TYPE MATERIAL RECOMMENDATIONS AND INSTRUCTIONS. SYMBOLS DESCRIPTION i � q. THERE WILL BE NO 5UB5TITUTION5 OF MATERIALS WHERE A MANUFACTURER 15 SPECIFIED. WHERE THE TERMS "EQUIVALENT TO" OR TOILET ACCESSORIES "APPROVED EQUIVALENT" ARE USED, H05 TO DETERMINE EQUALITY BASED ON INFORMATION SUBMITTED BY THE CONTRACTOR. EARTH OR COMPAGTED FILL 10. ALL WORK AND MATERIALS TO BE GUARANTEED AGAINST DEFEGTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR AFTER WINDOW / LOUVER TYPE ; APPROVAL OF FINAL PAYMENT. ' CONCRETE 11. THE CONTRACTOR 15 RESPONSIBLE FOR GUTTING AND PATGHING REQUIRED FOR H15 WORK UNLE55 OTHERWISE NOTED. 12, THE CONTRACTOR TO, AT ALL TIMES, KEEP THE PREMISES FREE OF ACCUMULATION OF WASTE MATERIALS OR RUBBISH; PREMISES MATCH LINE BRICK TO BE SWEPT GLEAN DAILY. 13. THE CONTRACTOR TO PROVIDE FINAL GLEANING OF ALL AREAS OF WORK INCLUDING THE CONSTRUCTION ACCESS ROUTE. FINAL GONGRETE MASONRY GLEANING TO INCLUDE WINDOWS AND CEILINGS, UNIT 14. DD NOT SCALE DRAWINGS; DIMEN51ON5 GOVERN. LARGER 56ALE DRAWINGS TO GOVERN OVER SMALLER SCALE DRAWINGS. REVI5I0N ALUMINUM 15. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR 15 RESPONSIBLE TO GET CLARIFICATION AND DIRECTION FROM HD5 PRIOR TO PROCEEDING WITH THE WORK. F= STEEL $ OTHER PROJECT BLOOM BEHAVIORAL LOCATIOPROJECTI6. ALL INSTALLED PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT TO OPERATE QUIETLY AND BE FREE OF VIBRATION. SOLUTIONS PLYWOOD Il. UNLE55 OTHERH15E NOTED IN MECHANICAL DRAWINGS OR SPECIFICATIONS, HOLD OUGT5 AND MECHANICAL EQUIPMENT TIGHT TO STRUCTURE ABOVE. NORTH ARROW GONTINUOU5 WOOD STH w 18. THE GONTRACTOR SHALL NOT LOCATE CEILING DIFFU5ER5 OR REGISTERS WHERE FULL HEIGHT SHELVING, FILES OR STORAGE FRAMING m UNITS ARE INDICATED ON PLANS. _- DISCONTINUOUS WOOD® I STfiV (. I I®O fiNSII ®NS Iq. ALL CEILING DIFFUSERS AND REGISTERS TO BE THE SAME COLOR AS THE CEILING AND OR MATCH THE BUILDING STANDARDS BLOCKINGNTIN OR SHIM D UNLE55 NOTED OTHERWISE. NUMBER INDICATES ORIENTED STRAND PER F5: 481.2131 Interior Design ractice re ulrement5• di5clo5ure of compensation for profe55ional services � 20. ALL SURFACES TO BE PROPERLY PRIMED OR PREPARED PRIOR TO INSTALLATION OF SPECIFIED FINISHES. ! � Tp � o_ ELEVATION BOARD (1) THE (ID) SHEETS CONTAINED IN THESE DOGUMENT5 WERE PREPARED BY A LICENSED AND REGISTERED TIIa°,sre"a D 21. ALL FIN15HE5 TO BE INSTALLED IN AGGOROANGE WITH MANUFAGTURER'S RECOMMENDATIONS AND INSTRUCTIONS FOR THE TYPE OF RESILIENT RESILIENT VCT A000 INDICATES DIRECTION OF DESIGN PROFESSIONAL. THE (ID) DRAWINGS ARE NOT ARCHITECTURAL OR ENGINEERING DRAWINGS AND SHALL NOT U I.. 1.....((((((((( FINISH WOOD ,,,,.......subatntre;,;;;;;;,;;; ............. otare,,,,,,,,,,, � DINSTALLATIONSPECIFIED. z VIEW BE USED FOR CONSTRUCTION OF ANY LOAD BEARING COLUMNS, LOAD BEARING FRAMING OR WALLS OF STRUCTURES co OR 155UANGE OF ANY BUILDING PERMIT EXCEPT AS OTHERWISE PROVIDED BY LAW. INTERIOR DESIGN DOCUMENTS w 22. PATCH ALL AREAS WHERE THE FLOOR 15 NOT LEVEL OR TRUE PRIOR TO THE INSTALLATION OF SPECIFIED FLOOR FINI5H(-E5). SHEET NUMBER WHERE THAT ARE PREPARED AND SEALED BY A REGISTERED INTERIOR DESIGNER MAY, IF REQUIRED BY A PERMITTING � � ELEVATION ELEVATION I5 DRAWN BATT INSULATION Q BODY, BE SUBMITTED FOR THE ISSUANCE OF A BUILDING PERMIT FOR INTERIOR GON5TRUCTION EXGLUDING DESIGN CAULK CONTINUOUS (rvPJ ►- 23. CONTRACTOR 15 RESPONSIBLE FOR PROVIDING ADEQUATE BLOCKING FOR WALL SUPPORTED ELEMENTS INCLUDING MILLWORK, BASE (SEE DESIGN DRAWINGS) y EQUIPMENT, FIXTURES AND FURNITURE. CONTRACTOR TO VERIFY EXTENT AND COORDINATE WITH APPROPRIATE SUBCONTRACTORS. OF ANY STRUCTURAL, MECHANICAL, PLUMBING, HEATING, AIR CONDITIONING, VENTILATING, ELECTRICAL OR VERTICAL p THINSET MASTIC TVP.) _ = RIGID BOARD TRANSPORTATION SYSTEMS OR THAT MATERIALLY AFFECT LIFE SAFETY SYSTEMS PERTAINING TO FIRE SAFETY v "-I. WOOD BASE A XWOOD BA3E m 0 24. PAINT TO BE APPLIED IN ACCORDANCE WITH THE MANUFAGTURER'5 OIREGTION5 OVER PROPERLY PREPARED 5URFAGE5. WALLS O NUMBER INDICATES WALL INSULATION PROTECTION SUCH AS FIRE -RATED SEPARATIONS BETWEEN INTERIOR SPAGE5, FIRE -RATED VERTICAL 5HAFT5 IN O FLOOR TILE SHOE MOLDING p Cf)) TO BE STRAIGHT AND SMOOTH. PROVIDE MINIMUM ONE GOAT PRIME AND ONE FINISH GOAT. FINISHED GOAT TO COMPLETELY COVER AO 0 SECTION MULT15TORY STRUCTURES, FIRE -RATED PROTECTION OF STRUCTURAL ELEMENTS, SMOKE EVACUATION AND U PORTLAND GEMENT WITH NO STREAKING OR BLEEDING OF UNDERGOAT5. ""``. PLASTER ON MTL LATH COMPARTMENTALIZATION, EMERGENCY INGRESS OR EGRE55 SYSTEMS, AND EMERGENCY ALARM SYSTEMS. SHEET NUMBER WHERE "'` w (STUCCO) ;;:3"otare ;s...... r„ a 25. UPON M F TH O COMPLETION O E WORK, THE CONTRACTOR TO NOTIFY BUILDING OWNER REPRESENTATIVE THAT THE PROJECT 15 READY SECTION 15 DRAWN (2) AN INTERIOR DESIGNER SHALL, BEFORE ENTERING INTO A CONTRACT, VERBAL OR WRITTEN, CLEARLY w FOR INSPECTION. OWNER REP WILL COMPILE A "PUNCH LIST" OF GORRECTION5 NEEDED, OF UNSATISFACTORY AND/OR INCOMPLETE DETERMINTE THE SCOPE AND NATURE OF THE PROJECT AND THE METHOD OF METHODS OF COMPENSATION. THE NUMBER INDICATES WALL � INTERIOR DESIGNER MAY AFTER PROFESSIONAL SERVIGE5 TO THE CLIENT A5 A CONSULTANT, 5PEGIFIER OR METAL TRANSITION INSTALL METAL EDGE WORK. FINAL PAYMENT WILL BE CONTINGENT UPON THE SUCCESSFUL COMPLETION OF THE PUNCH LIST. STRIP TIGHT TO METAL EDGE INDICATES DIRECTION OF A000 SECTION SUPPLIER ON THE BASIS OF A FEE, PERCENTAGE, OR MARKUP. THE INTERIOR DE516NER SHALL HAVE THE RESPONSIBILITY OF FULLY DISCLOSING TO THE CLIENT THE MANNER IN WHIGH ALL COMPENSATION 15 THE BE PAID. 0 26. DRYWALL CONTRACTOR TO CLOSELY COORDINATE HIS WORK WITH THAT OF OTHER TRADES. WHERE DRYWALL 15 IN CONFLICT GUTTING PLANE FLOOR U"DERUIVMENT MATERIAL OR LEVELING UNLESS THE CLIENT KNOWS AND AGREES, THE INTERIOR DESIGNER SHALL NOT ACCEPT ANY FORM OF COMPOUND SLOPED TO (10UNLE55WITH DUCTWORK, PLUMBING LINES, ETC. THIS CONTRACTOR TO PROVIDE ALL NECESSARY BRIDGING AND BRACING REQUIRED TO CREATEAFLUSH TRANSITION ADHESIVE Lu SHEET NUMBER WHERE GOMPEN5ATION FROM A SUPPLIER FOR 60005 AND SERVIGE5 IN GASH OR IN KIND. SECURE DRYWALL AND TO MAINTAIN FIRE OR SOUND RATING WHERE REQUIRED. SECTION 15 DRAWN a DETAIL ALL BE 10056 HANDICAPPED AGGE5SIBLE AFTER GONSTRUGTION AND w 2lBUILDING 5H ALL CONTRACTOR TO PROVIDE ADVANCE NOTIFICATION TO TENANT'S REPRESENTATIVE WHEN TENANT OR THEIR GONTRAGTOR(5) ARE WALL SECTION WooD ~ RENOVATION I5 COMPLETED. REQUIRED AT JOB SITE FOR COORDINATION MEETINGS OR INSTALLATIONS. ,5---- -----,;;, 0 s ~ 28. ALL FIRE EXTINGUISHER CABINETS OR ELECTRICAL PANELS LOCATED iN RATED PARTITIONS TO BE BACKED WITH GYPSUMS / I I ®NS z BOARD AS REQUIRED TO MAINTAIN PARTITION RATING. 1( z 51 6NV 0 j 2q. EXTEND ALL FIRE RATED PARTITIONS TO STRUCTURE; FILL ALL V0105 WITH FIRE 5AVING MATERIAL OR FIRE -RATED CAULK, o CONTINUOUS A5 REQUIRED BY CODE. G GAS MATL MATERIAL PL PLATE � q ANGLE CLF CHAIN LINK FENCE E EAST GLG GEILING EA EACH GA MAX MAXIMUM PLA5 PLASTER EL 30. CONTRACTOR 15 RESPONSIBLE FOR FIRE STOPPING ALL NEW AND EXISTING FIRE RATED PARTITIONS AND ALL PENETRATION AT GAUGE MOUNTING LOCATION $HEIGHT A.B. ANCHOR BOLT GLO CLOSET EB EXPANSION BOLT GALV GALVANIZED MB MARKER BOARD PL LAM PLASTIC LAMINATE WHEN PERMANENT THROUGH RATED AREAS INCLUDING SLABS. SEAL TO MAINTAIN PROPER RATING. ABV ABOVE GAL GALLON MOFB MEDIUM DEN5ITY FIBER BO PLBG PLUMBING IDENTIFICATION 15 PROVIDED a! GMT CERAMIC MOSAIC TILE EF EXHAUST FAN o AIG AIR CONDITIONING GMU CONCRETE MA50NRY UNIT EJ EXPANSION JOINT GB GRAB BAR MEGH MEGHANIGAL PWD PLYWOOD FOR ROOMS AND SPACES, 31. ALL WORK TO BE SCHEDULED DURING REGULAR BUSINESS HOURS UNLE55 NOTED OTHERWISE. AGOU5 ACOUSTICAL GO CASED OPENING EL ELEVATION (ABOVE DATUM) GENERAL CONTRACTOR RA15ED LETTERS SHALL BE a GG MED MEDIUM PORT PORTABLE ACT ACOUSTIC GEILING TILE GOL COLUMN ELEG ELECTRIC GROUND FAULT INTERRUPTER PROVIDED AND SHALL BE C0 32. MILLWORK TO CONFORM WITH AHI STANDARDS FOR PREMIUM GRADE MILLWORK. DRAWIN65 INDICATE DESIGN INTENT. COMB COMBINATION ELEV 6F1 MEZZ MEZZANINE PR PAIR D FABRICATOR 15 RESPONSIBLE FOR MILLWORK ENGINEERING. APDL ADDITIONAL ELEVATION (DRAWING) GL GLASS MEMB MEMBRANE PREFAB PREFABRICATED ACCOMPANIED BY BRAIL IN ADH ADHESIVE GONG CONCRETE ELEV/EL ELEVATOR GOVERNMENT CONFORMANCE WITH SECTION GOVT MDO MEDIUM DENSITY OVERLAY PRE55 PRESSURE ADJ ADJUSTABLE /ADJACENT GOND GONOUIT EMER EMERGENCY GR GRADE MFR MANUFACTURER PL PROPERTY LINE 11-15.5.6. 516N5 SHALL BE 33. PROVIDE ALL NECESSARY GUT -OUTS FOR THE INSTALLATION OF ELECTRICAL AND VOICE/DATA OUTLETS, THERMOSTATS, SWITCHES AFF ABOVE FINISHED FLOOR CONN CONNECTION ENGL ENCLOSURE GT GROUT MIN MINIMUM PSF POUNDS PER 5Q. FT. INSTALLED ON THE WALL / ADJACENT TO THE LATCH AND OTHER DEVICES. SEE ENGINEERS' DRAWING5 FOR LOCATIONS. AHU AIR HANDLING UNIT GONSTf,Z. CONSTRUCTION ENGR ENGINEER GyIB GYPSUM WALL BOARD MIR MIRROR PT PRESERVATIVE TREATED / OUTSIDE OF THE DOOR. o ALT ALTERNATE CONT GONTINUOU5 ENT ENTRANCE GYPSUM SHEATHING WHERE 34. WHERE PIPES, GONOUIT5 OR LOW TEN5ION WIRING PENETRATE A FIRE RATED ENCLOSURE, THE SPACE AROUND SHALL NOT EXCEED GYPS MISG MISCELLANEOUS PTD PAINTED AL ALUMINUM GONTR, CONTRACTOR EP ELECTRIC PANEL MM MILLIMETER PVG POLYVINYL // THERE IS NO WALL SPACE ON U) 1/2" AND SHALL BE PACKED 50LID WITH BATT INSULATION AND FITTED WITH ESCUTCHEON PLATES ON BOTH SIDES OR EQUIVALENT CORR CORRIDOR EPS EXPANDED POLYSTYRENE HI3 H05E BIBB MO MASONRY OPENING It_b1I THE LATCH SIDE, INCLUDING AT z TREATMENT TO INSURE COMPLIANCE WITH FIRE RATING. AMP AMPERE HANDICAPPED GHLORIOE(PIPE) / DOUBLE LEAF DOORS, SIGNS (D ANOO ANODIZED GPT CARPET EQ EQUAL HG MOD MODULAR PVMT HOLLOW GORE PAVEMENT / _ SHALL BE PLACED ON NEAREST AP ACCESS PANEL GRS GOUR5E(5) EQUIP EQUIPMENT HGORE MRB MARBLE PWD PLYWOOD / - ADJACENT WALL, PREFERABLY 0 35. WHERE DUCT OR PART OF DUCT IS RUNNING PARALLEL OVER FIRE RATED PARTITION, EXTEND RATED PARTITION AROUND DUCT TO G5 GAST STONE ETR EXISTING TO REMAIN HDR HEADER MT METAL THRESHOLD / APPROVED HARDWARE I I ON THE RIGHT. MOUNTING EFFECT COMPLETE MAINTENANCE OF FIRE -RATING. APPD. LSAT CONGEALED SPLINE EW EACH WAY o ARCH ARCHITECT (URAL) HOW HARDWOOD MTL METAL QT QUARRY TILE / I HEIGHT SHALL BE BETWEEN 48" A5PH ASPHALT ACOUSTICAL TILE ENG ELECTRIC WATER COOLER HDWD MULL MULLION QTY QUANTITY \ 0 36. ALL DOORS TO HAVE BUILDING STANDARD HARDWARE. PROVIDE PANIC HARDWARE AS NEEDED FOR EGRESS / EXIT DOORS CT CERAMIC TILE EXI5T EXISTING HT HEIGHT MAX. ABOVE: THE FINISH FLOOR AVE AVERAGE MTD .MOUNTED \ � I� GTR COUNTER EXP EXPOSED HM HOLLOW METAL R I IT_ TO TEH GENTERLINE OF SIGN. 31. CONTRACTOR TO COORDINATE WITH OWNER THE SALVAGE / REUSE OF EXISTING DOORS, SIDELIGHTS, HARDWARE ITEMS, EXISTING EXT HORIZONTAL N NORTH RISERS (ON STAIRS) \ i I= MOUNTING LOGATIN SHALL BE BD BOARD D DRAIN EXTERIOR (OR EXTENSION) HOR R/A RETURN AIR \ O CL MILLWORK AND OR SYSTEM FURNITURE, TYP. BF BI -FOLD (DOOR) DA DOUBLE ACTING EHH ELECTRIC WATER HEATER HP HIGH POINT NATL NATIONAL RAD RADIUS \ I Ids Il DETERMINED 50 THAT A a. BIT BITUMINOUS HR HOUR NGVO NATIONAL GEODETIC VERTICAL RD ROOF DRAIN \ I I PER50N MAY APPROACH WITHIN w 38. GONTRAGTOR5 MUST V151T 51TE TO VERIFY FLOOR PLAN BUILDING TYPE AND CONSTRUCTION. DB DECIBEL FA FIRE ALARM \ I 3" WOTHOUT ENCOUNTERING _ � BLDG BUILDING HTR HEATER DATUM RDI_ ROOF DRAIN LEADER DIR DIRECTORY FBO FURNISHED BY OTHERS HVAC HEATING, VENT.$ AIR GOND. NIG NOT IN CONTRACT REG RECEPTOR \ 1 1 PROTRUDING OBJECTS OR ~ BLK BLOCK a 3q. PROTEGT EX15TINO WORK WHIGH IS TO REMAIN IN PLACE BE REUSED, OR REMAIN THE PROPERTY OF THE OWNER. DEG DEGREE HOT WATER NO NUMBER I FD FLOOR DRAIN HW REGT RECTANGLE \ I STANDING WITHIN THE SWING OF BLKG BLOCKING DEMO DEMOLITION FON FOUNDATION NOM NOMINAL REF REFRIGERATOR THE DOOR, 0 40. GONTRAGTOR TO REFER TO ENGINEERS DRAWINGS FOR SCOPE OF WORK REGARDING MEP. BM BEAM DEPT DEPARTMENT INSIDE DIAMETER NTS NOT TO SCALE FE FIRE EXTINGUISHER ID REF REFERENCE TACTILE SIGNAGE ° > B.M. BENCH MARK FEG FIRE EXTINGUISHER GA51NET I.L.O. LLw DEP DEPRESSED IN LIEU OF OA OVERALL REFL REFLECTED (CEILING) u. 41. CONTRACTOR TO PROVIDE 5EAMLE55 INSTALLATION BETWEEN OLD AND NEW FINISHES. BRG BEARING PLATE OF DRINKING FOUNTAIN FF FIRE RES15TANT TREA-ED WOOD IN INCH REG X10 ' BEARING DIA DIAMETER INSULATION OBS OBSCURE (GLASS) REGLET «, y r k FIRTH FINISH FLOOR INSUL REINF m x 0 z 42. EXISTING AREAS TO REMAIN A5 15 UNLESS NOTED OTHERWISE: BRK BRICK DIAL DIAGONAL INTERIOR OG ON CENTER REINFORCEMENT n FFE FINISHED FLOOR ELEV?�TION INT w BTM BOTTOM DIFF DIFFUSER OD OUTSIDE DIAMETER RE51L RESILIENT x D BTU F$ I FURNISH AND INSTALL OFF OFFICE REVS; D 43. PLUMBING AND LIGHTING FIXTURES 5HOWN FOR COORDINATION PURPOSES ONLY. CONTRACTOR TO COORDINATE LOCATIONS OF BRITISH THERMAL UNIT DIM DIMEN51ON REQUIRED $Z -I FHG FIRE HOSE CABINET OGD REVISION(5), REVISED„ COMMUNICATIONS, DATA, DEDICATED CIRCUITRY AND OR ADDITIONAL ELEGTRIGAL REQUIREMENTS WITH OWNER. BTWN. BETWEEN DIS DISPENSER JAN JANITOR OVERHEAD GARAGE DOOR>� FIN FINISHED RFH ROOF HATCH ROOM `�„ z ,�, w " `� �R BUILT UP ROOF DO DOOR OPENING J5T J015T (FLOOR OR ROOF) OHO OVERHEAD DOOR z FIXT FIXTURE JOINT OJ OPEN HEB STEEL J015T5 RM ROOM z `°� N m Z 44. CONTRACTOR TO RELOCATE ANY EXISTING WALL OR CEILING DEVICES AS REQUIRED WITHIN THE MEANS OF THE DESIGN INTENT. G CHANNEL DP DAMPPROOFING FL FLOOR JT c w GAB CABINET DN DOWN OPER OPERABLE R0 ROUGH OPENING -� FLUOR FLUORESCENT R$5 a 45. CONTRACTOR TO COORDINATE WITH OWNER THE SALVAGE / RELOCATION OF EXISTING LIGHTING FIXTURES, FANS, ETC... GAP CAPACITY OR DOOR FP FIREPROOFING KD KNOGKDOHN (CEILING) OPNG OPENING RT ROD $ 5HELF(5) z GB CATCH BA51N DRY DRYER (MACHINE) FPL FIREPLACE KIT KITCHEN OPP OPP051TE RUB RUBBER TILE w 46. CEILINGS TO REMAIN AS IS UNLE55 NOTED OTHERWISE. REGONFIGURE EXISTING GEILING TILES AND LIGHT FIXTURES AS REQUIRED. GEM GEMENT 05 DOWNSPOUT FOS FACE OF STUDS K/5 KNEE SPACE OPT OPTIONAL RUBBER / z GFT CUBIC FEET DTA DOVETAIL ANCHOR 055 ORIENTED STRAND BOARD �r p FRT FIRE RETARDANT TREATED. 41. MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION ENGINEERING ARE NOT INCLUDED WITHIN THE BASIC SCOPE OF GFM CUBIC FEET PER MINUTE OT 5 DOVETAIL SLOT L LENGTH OZ OUNCE ; I; A ; �` FT FOOT BE_ SERVICE AND, PER OUR UNDERSTANDING, WILL BE PROVIDED AND PERFORMED AS A DESIGN / BUILD SERVICE BY THE GENERAL GG GORNER GUARD DW DISHWASHER FTG FOOTING LAB LABORATORY z CONTRACTOR. ITEMS SHOWN ON THE DRAWING5 PERTAINING TO M.E.P., 5TRUGTURAL AND OR FIRE PROTEGTION ARE SHOWN FOR GHAM CHAMFER DWG DRAWING FURR FURREO(ING) LAM LAMINATED #, LB POUND a COORDINATION PURP05E5 ONLY. GHG CHANGE OHR DRAWER FUT FUTURE LAV LAVATORY PAR PARALLEL `nGI GAST IRON LOR LEADER PART PARTITION JAN 2 % 2020 z 48. CONTRACTOR TO PROVIDE FIRE EXTINGUI5HER(5) AS NEEDED PER RENOVATION. GIP GAST IN PLACE LGMF LIGHT GAGE MTL FRAMING PBD PARTICLE BOARD GJ CONSTRUCTION JOINT LH LEFT HAND PC PRECAST (CONCRETE) PED PEDESTAL (SINK) 1930110 ino i'rlartji-�'± fk 4q. ALL CONCRETE FLOOR SLABS, EXISTING OR NEW, MUST BE PREPPED PER ASTM F 1GL GENTERLINE LIN FT LINER FEET 10 AND TESTED PER ASTM F 2110 PRIOR TO PFB PREFABRICATED E";Ia),y nf e��Ia G d�%cf :, �, 1.., " RECEIVING ANY RESILIENT FLOORING SPEGII=IED. FIRE EiCTINOUISi-iER MNT. HT. HOTA DESIGN STUDIO, LLC INTERIOR DESIGN 31 West Adams Street, Ste.103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com I8-28001328 J Q W REVISIONS: MLOINS REVIEW C 4,11E T8 1-23-20 THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC F Flo io 9 No. 0 o�Nr RIO��� X= A. CANNNU DATE: 11-08-2019 INDEX, CODE INFO., ABBREV., REF SYMBOLS DRAWN BY: JC CHECKED BY: JC ' PROJECT NO.: 19043.00 V�J V� 01 y PERMIT SET N 0 H .�. (n Z� p O O 0 IL` > F m V m .J Z z O , O (An H Q< O J m W REVISIONS: MLOINS REVIEW C 4,11E T8 1-23-20 THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC F Flo io 9 No. 0 o�Nr RIO��� X= A. CANNNU DATE: 11-08-2019 INDEX, CODE INFO., ABBREV., REF SYMBOLS DRAWN BY: JC CHECKED BY: JC ' PROJECT NO.: 19043.00 V�J V� 01 y PERMIT SET m N F- C) Z 0 O r a U` W z F- U Q Z a � 'NIH C)CV Q H w z *' N Q z cj J °� cV M U z LL E J Q Q v Qj W N 0 o > 04 o oNo � 1Nvcin,Dg0 m 9 z o 2 co a m N F- C) Z z z a U` W z F- U Q Z a � 'NIH C)CV Q H w z U U 0 Q z fY J °� N Iz .' Q o z V � Q 0° m o O Q 1Nvcin,Dg0 tY .. z (NAd a,032i I LL J LU 6A61A 8cd - - — 6 Q F= w ® �m W NIW w L a w — w LL p LU o< O z Vo C0 4 Z CII) W4 a�c'Jlni��c1 - Q z Q j Q W a O _ w V L :... ON o °' o m P :3 N N9W �!iAcd o Q � E s -jo O A o JI !f0iVAV I =< z O z Q QF - o m w LL F -z w °o 6 V > � x x 0 O CD a o LL LL t CD Q N O �, > t D- N LL o (N L W o CV o V m LL N � 0 W o L z -C3 W o tV o tJ CD o LL 0 N m �s� V v p z c m s H p Z d1 �Y o 6 m �9 z X W c z `x W Q Z 1- O CN O (N d- c N m 0 zp a ¢Qz www 90)0 a. CL 0o w _Of z 0 5 u_o� w X 2zw Lu a a O Q O zwWa.LU o O�z �Wo _Z 0 ��n/� �w x vJ f— aprOf O w �a.F-�UoJ Zgl-ti �U W o 0 0>G `- X v U U L u w M c n ~ _`'*-#_ W F- 0 0 a ¢Qz w� > U) 00� 0- o w L Zoe XZ w LU GJ J w �QQ 0 0 �n z�LL LLJ w w aEa V O _ o�Z o W Z o _O�Qq 11 C) u 0 = W- M N 0F--�^U - X V/ UQU� a_0a CL Q o Q O W � a.F-� Ups ZMFx-� F -t U w 00 L) LLI co c,) LU it 11Nf1 '4A1H JI1NVlltl L66 SNOunios IVNOIAVH39 W0019 F- C) Z z z a U` W z F- U Q Z a � 'NIH C)CV Q H w z U U 0 Q z fY J °� N Iz .' Q o z Z � Q 0° m o O Q 1Nvcin,Dg0 tY .. z (NAd a,032i I LL J LU 6A61A 8cd - - — Q Q F= w ® �m W NIW w L a w — w LL p LU o< O z Vo C0 4 Z CII) W4 a�c'Jlni��c1 - Q z Q j Q W O _ o a o X W O L :... ON o °' o m P :3 N N9W �!iAcd o Q D E -jo O A o JI !f0iVAV I =< z O z Q QF - o m w LL F -z w °o 0 0 - 0 t Q z w pi =Z=� PO W LU ry - - o Q P z s? pWOv a� v - p 6�LU A nl O3 LY z z ,per, � O- aAalh0?1d - Q 0 N �' v v 0 Z Q 7- a,n�1 w _ LU W o x x m 3 'NIW O O a o L (3 N V O Ln �� ALL O o Z A�bwAA �Idd O ° � ° � Z O O 9 a�?JInO3Z! N Z ® 1�50-l0 Navin I N - +. LL w O Q t15 p 60) `" Q QWv LL 1k Q p m -. NAW ?1Gd ° 4 q)Z > z LL CN W Z (L w z o lU V 1�50�0 Z kD l4 v LU v Q L Z tt�W p o N Lu UJ o •� O ,n In IZ oe w w � om o N z w LU V ).oNedm90 m N Lu a L O m a to O O x !Y _0 �? p Q d Q Ql LU Q v ,n L p Tn E OQ Q V O W- F W Ww O cYw Z LU QO, 6 6 O 9 6 v cl J W > v 4 0 0 Q n Lu ° 3 Q ILI N NO i 0- LL 6 N 6 6 p > )D v Q N �} v Vs Z V 6 J 6 O L tu v o v ,� = Q O N s !L O U p 6 lU LL l)L c v L N E N O O N N a O E p v LL1 X tu c N �. a Q- Q L� L 4 O O v O = w N v Lu C� f W 0 zp a ¢Qz www 90)0 a. CL 0o w _Of z 0 5 u_o� w X 2zw Lu a a O Q O zwWa.LU o O�z �Wo _Z 0 ��n/� �w x vJ f— aprOf O w �a.F-�UoJ Zgl-ti �U W o 0 0>G `- X v U U L u w M c n ~ _`'*-#_ W F- 0 0 a ¢Qz w� > U) 00� 0- o w L Zoe XZ w LU GJ J w �QQ 0 0 �n z�LL LLJ w w aEa V O _ o�Z o W Z o _O�Qq 11 C) u 0 = W- M N 0F--�^U - X V/ UQU� a_0a CL Q o Q O W � a.F-� Ups ZMFx-� F -t U w 00 L) LLI co c,) LU it 11Nf1 '4A1H JI1NVlltl L66 SNOunios IVNOIAVH39 W0019 0) VMI 0 N M� W 0 r F- C) Z z z a U` W z F- U Q Z a z 'NIH C)CV Q H w z U U 0 Q z fY J °� tY � �w Iz .' Q o z Z � Q 0° m o O Q 1Nvcin,Dg0 tY .. z (NAd a,032i I LL J LU 6A61A 8cd - - — Q Q F= w ® �m W NIW w L a w — w LL p LU o< O z Vo C0 4 Z CII) W4 a�c'Jlni��c1 - Q z Q j Q W ,IZIOltfl�y� I o a o X W O L :... ON o °' o m P � N N9W �!iAcd o Q D E -jo O A o JI !f0iVAV I =< z O z Q QF - o w LL F -z w °o *XASINn - - Lu Q t Q z w pi =Z=� PO W LU ry - - z L l Q P z s? pWOv a� v - p 6�LU N nl O3 LY z z ,per, O- aAalh0?1d - Q v czQLU U-iJ 0 Q 7- a,n�1 _ _ LU W o x x 3 'NIW ID U- a _ mCL N V Ln �� ALL O A�bwAA �Idd ° � ° � Z O O a�?JInO3Z! s pLU LLJ [Y I--- F- IIcL 1�50-l0 Navin I N - +. LL w O Q t15 p 60) `" Q QWv LL 1k Q p m NAW ?1Gd ° 4 q)Z z LL CN W Z �, w z o - 1�50�0 Z kD v LU v Q L Z tt�W z2LLJ Lu UJ o 1Nbdn000 ii�101 In IZ -j X z Q = w w � om o N z w LU ).oNedm90 m W lU w Z � z – w Lu L O m a to tt1 N x !Y X DY O Ov � �? p Q d Q w LU Q v �x p z z OQ Q O W- F W Ww F- cYw w0 LU QO, O LUQ O Q v 0) VMI 0 N M� W 0 r F- C) Z z z a U` W z F- U Q Z a 0 'NIH C)CV Q H w z U U 0 Q z F- 'NIH J °� tY � �w Iz .' Q o z Z � X LU w U) 0° m o O Q 1Nvcin,Dg0 O .. z (NAd a,032i I LL J LU 6A61A 8cd - - — Q Q F= w ® > W NIW w L a w — w 0) VMI 0 N M� W 0 r a F- C) Z LU 0 Q a U` W z F- U Q Z a 0 'NIH C)CV Q H w z U U 0 Q = F- O_ w J °� CD Iz .' Q o z Z � X LU w U) 0° m o O Q .. z C/) I- LL J Z Q a,r��� — — Q F= w ® > w NIW w L a w — w LL p LU o< O z Vo NAWOM add add CII) W4 a�c'Jlni��c1 - Q j Q W ,IZIOltfl�y� I o a o X W O L :... ON o °' o m � N N9W �!iAcd o Q E -jo O A JI !f0iVAV I �' =< z O z Q QF - w LL F -z w °o *XASINn - - Lu Q Q z w pi =Z=� PO LU aAa VAONd - - z L l Q pWOv a� v - LU Q 'NIH LY z z ,per, O- aAalh0?1d - z�0 QO p z w z v czQLU U-iJ -_a v(til LL — LL Z Q 7- a,n�1 _ _ LU W o x x 3 'NIW i- N 0 LU _ Ln �� ALL O A�bwAA �Idd ° � ° � Z O a�?JInO3Z! s pLU LLJ [Y I--- 1�50-l0 Navin I N - +. LL w O Q p 60) `" QWv LL 1k Q NAW ?1Gd ° 4 q)Z z LL a iNinoAN �, w z o - 1�50�0 v LU v Q L Z tt�W ado Lu UJ o 1Nbdn000 ii�101 C -j X z Q = w w � om o N z ).oNedm90 m W lU w Z � z – w L AAAA -96112 1"d101 X DY O Ov � � m U a F- C) Z LU 0 Q a U` W z F- U Q Z a 0 we wcwn Qw C)CV Q H w z U U 0 Q = F- O_ w J °� CD Ci) 1WCG o U Z F— ~ Q C)CV Q H w z U U 0 O = F- O_ w J °� w Iz .' Q o z Z � X LU w U) 0° m o J wW .. CD C/) I- LL J Z Z w WCD�Qmo w ® a w I— w L a w — w --3 O CII) W4 L :... ON � N z .ZE O �jU- V V Y Q � o 0 = xdH M .84 2 z � <Z z pi xdw .Ll Q J � ~ z xvw f% 0 0 xdW v m 0 F- 000- LL Q z w w O 0 of U 8 LU 00IX z0:D L� o CY UJ W ��OfJ w m¢U p a UJ Q O w zp¢c7 <a z ¢ _� O~ wL U ° u = wM N F- U x ZF=cn Qof W Q U a 0 Q Q o ¢ O w F- F- U O Xo x o U w r- W c*) cM c XVI -4 � u'i 1311!10 1WCG .9E U Z Z F- z CL Q H w z U U 0 Z O F- O_ w cn F -Q z w Iz .' Q o z ¢ E X LU w U) 0° m m 0 F- 000- LL Q z w w O 0 of U 8 LU 00IX z0:D L� o CY UJ W ��OfJ w m¢U p a UJ Q O w zp¢c7 <a z ¢ _� O~ wL U ° u = wM N F- U x ZF=cn Qof W Q U a 0 Q Q o ¢ O w F- F- U O Xo x o U w r- W c*) cM c XVI -4 � u'i 1311!10 1WCG .9E Z Q NIW z .LZ O z NIW n F .b ? Z E Q m �o j "G31lGIHObd SI 011 OldniS NJIS30 ` iOH A9 NOISSIVIN3d N31-LINM 03SS3NdX3 inOHilM N011onGOUd3M NO dNV 3Sn .lNV '011 'OIan1S NJIS30 V-LOH -40 AL83dOUd 3H14N`d 301AN3S 301N3WnNiSNI NV 3UV S1N31N00 Sll (INV SJNIMb21momi a SIH1 w 0 0 z Lu Q U J J 0 F— z W 0 x LL 0 w EL Ix a w x h 0 z U w u- 0 0 F—' z Lu g F- U) z z ¢ w x ¢ F- z w F - z 0 0 H 0 Q U) 0 Z 0 CD F - . DEMOLITION PLAN 1/4 11 = I I—OII DEMOLITION NOTES I. DEMO SELECT EXISTING HALLS, PORTIONS OF HALLS AND MILLWORK AS INDICATED. 2. CONTRACTOR TO COORDINATE THE SALVAGE AND OR REUSE OF DOORS, FRAMES, L 16HT I N6, AND CEILINGS WITH OWNER 5. PROTECT EXISTIN6 WORK HHIGH 15 TO REMAIN IN PLACE BE REUSED, OR REMAIN THE PROPERTY OF THE OWNER. 4. REMOVE AND STORE MATERIAL AND EQUIPMENT INDICATED TO BE REUSED OR RELOCATED TO PREVENT DAMAGE, AND REINSTALL AS THE WORK PR06RE55E5. 5. WHERE EXI5TIN6 5URFAGE5 ARE TO RECEIVE NEW FINISHES, REMOVE ALL EXI5TIN6 FINISHES. PREPARE SURFACE TO RECEIVE NEW FINISHES. REPAIR AND OR REPLACE SURFACE IF NEEDED. 6. IN THE EVENT A HALL OR BUILT-IN ITEM 15 REMOVED FROM AN EXISTING SURFACE TO REMAIN. REPAIR, PREP AND FINISH 5URFA6E AS SCHEDULED FOR UNIFORM APPEARANCE. -7. IN THE EVENT A HALL 15 REMOVED OR ADDED AND THE TWO ADJACENT GEILINO GRID ARE NOT ALIGNED, REMOVE THE GRID WITH THE LEAST AMOUNT OF IMPACT AND REALIGN GRID FOR A MONOLITHIC APPEARANCE PARTITION LEGEND _ — GYP. PARTITION, DEMO 6YP. PARTITION, EXISTING NEW PARTITION IHR PARTITION HOTA DESIGN ST LJDIQ LIC INTERIOR DESIGN 31 West Adams Street, Ste. 103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com IB -28001328 REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC !�E OF Flo " -N N o. 41� l � yc p 0 �FER10 JOSE A. CAREE R tip tttt• I DATE: 11-08-2019 DEMOLITION PLAN DRAWN BY: JC CHECKED BY: JC O)$ PROJECT NO.: 19043.00 461.C COPY ID�l PERMIT SET O H z Q O 0 O LJJcn � _V m -� F— Zz V O J � o `� F- a 0 J m REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC !�E OF Flo " -N N o. 41� l � yc p 0 �FER10 JOSE A. CAREE R tip tttt• I DATE: 11-08-2019 DEMOLITION PLAN DRAWN BY: JC CHECKED BY: JC O)$ PROJECT NO.: 19043.00 461.C COPY ID�l PERMIT SET 6 F- 0 It 0- N U J J O 0 _ z c7 w ❑ O m z 0 U) U) W a w r - Ix Lu w a x Lu _ O z 0 F- U D ❑ a w Ix O z Q W _ z Q U J J 0 0 _ z W ❑ O 2 LL. 0 W 0- 0 af 0- w H ❑ z Q W U W U LL 0 P - z W z z Q w Q z w z 0 U ❑ Q Z ❑ I 6.V61I\ I 6r1jN /4�I FLOOR PLAN NOTES I. ALL HALL TYPES TO BE TYPE I UNLE55 NOTED OTHERWISE. SEE SHEET ID -2 FOR NEW GON5TRUGTION PARTITION TYPES. 2. HHERE EXISTING OPENIN65 ARE TO BE GL05ED, ALIGN NEW PORTION FLUSH WITH ADJAGENT 5URFAGE FOR UNIFORM APPEARANCE, TYP 3. 6C TO PROTECT ANY 5URFAGE THAT ARE TO REMAIN AND BE REUSED, 4. 6G TO REPAIR AND PREP ANY DAMAGED 5URFAGE5 AS REQUIRED TO RECEIVE NEW FINISHES. 5. 6G PREP EXI5TIN6 5URFAGES TO RECEIVE NEW FINISHES FOR UNIFORM APPEARANCES. (b. WHERE OPENING ARE SHOWN, PROVIDE 36" HIDE 6HB OPENINGS, TYP 7. NEW DOORS AND FRAMES TO MATCH EXISTING BUILDING STANDARDS, TYP PARTITION LEGEND _ _ — GYP. PARTITION, DEMO GYP. PARTITION, EXISTING NEW PARTITION IHRPARTITION KEYNOTE PLAN NOTES A) B) Cl) D) NEW 4' WIDE DOUBLE SLIDING GLASS WINDOW E) PROVIDE CARD READER AT TH15 DOOR F) REFRESH FINISHES, LIGHTING a FIXTURES IN EXISTING RE5TROOM5, TYP G) ROOM 112 TO UTILIZE FLOOR TO GEILIN6 PLYWOOD SUBSTRATE WITH WG -I, HALL GOVERING FINISH PARTITION TYPE GENERAL NOTES: I. ALL TYP INTERIOR PARTITIONS ARE TO BE TYPE I UNLE55 NOTED OTHERWISE UNDERSIDE OF 5TI;Vr V; E GLN6. A5 5GHED. 5/6, ae ON 3 5/6, PETAL 5f11D5 TYPE [T] TO UNDER51DE OF CEILING HOTA HOTA DESIGN STUDK), LLC INTERIOR DESIGN 31 West Adams Street, Ste. 103 Jacksonville, Fl- 32202 P: 904.632.4800 www.hotadesign.com IB -26001326 p E Cie O ~ Q O 0 J m W � � V m .J Z z ,7E 0 Cn Q OO� REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC of Fro �o\ 9 9 o. 41 r L m S '0IyTERI0�' R uc1 IDMI DATE: 11-08-2019 FLOOR PLAN DRAWN BY: JC CHECKED BY: JC /�► PROJECT NO.: 19043.00 4'* Fc OI D�2 I_ y PERMIT SET 0 Q Z 0 U F- 6 Z w I= 0 w W it a.x W RE�LEGTED GE I L I NG PLAN 1/41' 11-011 a I CEILING PLAN NOTE5 I. MEGHANIGAL, ELEGTRIGAL, PLUMBING FIRE PROTECTION AND STRUGTURAL ENGINEERING ARE NOT HITHIN SCOPE OF SERVICE. ITEMS INDICATED ON PLAN FOR COORDINATION PURPOSES ONLY. REFER TO ELEGTRIGAL ENGINEERS DOGUMENT FOR LIGHTING SELEGTIONS. 2. EXISTING AGOU5TIG CEILINGS TO REMAIN. UNLESS NOTED OTHERWISE 3. GG TO ALTER, REPAIR AND OR REPLAGE EXISTING GEILING GRID AND TILES AS REQUIRED. 4. RELOCATE EXISTING LIGHTING AND GEILING DEVIGE5 AS REQUIRED PER DESIGN INTENT. 5. LOCATE LIGHTING CENTERED IN ROOMS AS BEST AS POSSIBLE. 6. GG TO SALVAGE, RELOGATE AND REUSE EXISTING LIGHT FIXTURES. IF NEW FIXTURES ARE REQUIRED, MATCH BUILDING STANDARDS. REPLAGE ANY MISSING OR INOPERABLE LAMPS AS REQUIRED. MATGH ALL COLOR TEMPERATURES. 7. REFER TO ELEGTRIGIAN5 DRAWINGS LIGHTING LAYOUT AND SHITGHING LOCATIONS HOTA DESIGM STUDK� LLC INTERIOR DESIGN 31 West Adams Street, Ste. 103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com IB -26001326 REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC � OF Floyd i 4x-' q DATE: 11-08-2019 REFLECTED CEILING PLAN O DRAWN BY: JC CHECKED BY: JC PROJECT NO.: 19043.00 Fc OA y ID�3 PERMIT SET 0 Q O O M = W � _V m Z 0 a < O J M REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC � OF Floyd i 4x-' q DATE: 11-08-2019 REFLECTED CEILING PLAN O DRAWN BY: JC CHECKED BY: JC PROJECT NO.: 19043.00 Fc OA y ID�3 PERMIT SET 0 Lu CO O a U J J O ❑ D U) z O w ❑ 0 x co z 0 U) f Lu a z w r it ❑ w w ry a x w O S z 0 U D ❑ O a Li w it O ❑ z ¢ w z U J O F- U) z Cn w 0 x LL 0 w a O a w x ❑ z w U w U LL 0 H z w g ❑ H _z z a w Q z w z 0 U F z ¢ z ¢ ❑ U) 6 �LOOR � I N15H PLAN 1/4" = 1'-0" 6ENERAL FLOOR FINISH NOTES I. UNLE55 OTHERHI5E INDICATED, TRAN5ITION5 BETHEEN 01551MILAR MATERIAL5, FIN15HE5 AND/OR GOLOR5 TO OCCUR AT INSIDE CORNER. 2. SUBMIT FIN15H 5AMPLE5 OF 5PEGIFIEO FIN15HE5 FOR APPROVAL BY OHNER PRIOR TO ORDERING. 5. IN5TALL MODULAR FLOORING PRODUGT5 (GERAMIG, VGT AND LINOLEUM TILE5) HITH FULL AND GUT TILE5 A5 INDICATED. WHERE NOT INDICATED, TILE TO BE CENTERED ON ROOM. 4. INSTALL ALL FIN15HE5 IN ACCORDANCE HITH MANUFAGTURER'5 DIREGTIVE5. 5GOPE OF WORK TO INCLUDE RECOMMENDED GLEANING, 5EALER5 AND/OR TREATMENT5. 5. MITER GUT TRANSITION MOLDINC75 AT GORNER5. 6. UNLE55 OTHERN15E INDICATED, TRAN5ITION5 BETHEEN DI551MILAR MATERIAL5 TO OCCUR ON GENTERLINE OF DOORS -1. THE CONTRACTOR SHALL NOTIFY DE516NER5 OF ITEMS REQUIRING FINI5H 5ELEGTION5 THAT ARE NOT CLARIFIED IN THE DOGUMENT5. 8. ORIENT PLANK DIRECTION A5 INDICATED ON PLAN. HOTA DESIGN STUDIO, LLC INTERIOR DESIGN 31 West Adams Street, Ste. 103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com IB -26001326 'o- 6ENERAL FLOOR FINISH NOTES I. UNLE55 OTHERHI5E INDICATED, TRAN5ITION5 BETHEEN 01551MILAR MATERIAL5, FIN15HE5 AND/OR GOLOR5 TO OCCUR AT INSIDE CORNER. 2. SUBMIT FIN15H 5AMPLE5 OF 5PEGIFIEO FIN15HE5 FOR APPROVAL BY OHNER PRIOR TO ORDERING. 5. IN5TALL MODULAR FLOORING PRODUGT5 (GERAMIG, VGT AND LINOLEUM TILE5) HITH FULL AND GUT TILE5 A5 INDICATED. WHERE NOT INDICATED, TILE TO BE CENTERED ON ROOM. 4. INSTALL ALL FIN15HE5 IN ACCORDANCE HITH MANUFAGTURER'5 DIREGTIVE5. 5GOPE OF WORK TO INCLUDE RECOMMENDED GLEANING, 5EALER5 AND/OR TREATMENT5. 5. MITER GUT TRANSITION MOLDINC75 AT GORNER5. 6. UNLE55 OTHERN15E INDICATED, TRAN5ITION5 BETHEEN DI551MILAR MATERIAL5 TO OCCUR ON GENTERLINE OF DOORS -1. THE CONTRACTOR SHALL NOTIFY DE516NER5 OF ITEMS REQUIRING FINI5H 5ELEGTION5 THAT ARE NOT CLARIFIED IN THE DOGUMENT5. 8. ORIENT PLANK DIRECTION A5 INDICATED ON PLAN. HOTA DESIGN STUDIO, LLC INTERIOR DESIGN 31 West Adams Street, Ste. 103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com IB -26001326 DATE: 11-08-2019 FLOOR FINISH PLAN DRAWN BY: JC CHECKED BY: ,1C O/: PROJECT NO.: 19043.00 �C 040 I D�4 PERMIT SET CN o > Z = C ad Q O>LL- -, O L.LJ � _V m Z O -j -j O Q OCT .. W REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC DATE: 11-08-2019 FLOOR FINISH PLAN DRAWN BY: JC CHECKED BY: ,1C O/: PROJECT NO.: 19043.00 �C 040 I D�4 PERMIT SET 0 w m a U J J _O 0 H z c� Lu 0 0 z O U) Lu CL 0 0 z a Lu co D } z Q U J J O F- H z c� w a O X IL O w a O w 0- w w F- 0 z Lu U Lu U LL 0 F - z w w F - z z Lu ¢ F- z w I - z 0 U F- 0 a U) z 0 U) H - ,—j\, BURN I TURA PLAN 1/411= lI_OII F-URNITURE PLAN NOTES I. MEGHANIGAL, ELEGTRIGAL, PLUMBING FIRE PROTEGTION AND STRUGTURAL ENGINEERING ARE NOT WITHIN SCOPE OF 5ERVIGE AND SHALL BE PROVIDED BY OTHERS. Z. FURNITURE SHORN FOR COORDINATION OF ELEGTRIGAL AND DATA LOCATIONS. 3. ELEGTRIGAL AND DATA SYMBOLS LOGATED FOR COORDINATION PURPOSES ONLY. REFER TO ELEGTRIGIANS DOGUMENT5 4. LOCATE WALL MOUNTED TV'S © 60" A.F.F., TYP. LOCATE ELEGTRIGAL / DATA / AND GABLE BEHIND TV 5. WHERE MILLWORK 15 TO BE LOGATED, PROVIDE OUTLETS ABOVE COUNTER TOP AND SPLASH 6. GG TO VERIFY WITH OWNERS FUTURE LOGATIONS OF APPLIANGES AND OR EQUIPMENT FOR ELEGTRIGAL NEEDS SYMBOL LEGEND 4) ELEGTRIGAL OUTLET P- DATA OUTLET -® WALL MOUNTED TV HOTA DESIGN STUDIO, ILC INTERIOR DESIGN 31 West Adams Street, Ste. 103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com IB -26001326 J Q Ce CN o ~ .� Z Q Da > O m W m V H m J Z u z 0 J o Q� O ..J M REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC E OF Flo 9 r V \ 5 rER10���/ J=wCAPON" R ua n.ow DATE: 11-08-2019 FURNITURE PLAN DRAWN BY: JC CHECKED BY: JC PROJECT NO.: 19043.00 F co I D�5 PERMIT SET it 0 a z a w z a U J J z a w a z w z 0 0 a (D Z a U) 6 DOOR SCHEDULE PLAN TAG DOOR FRAME HARDWARE REMARKS TYPE WIDTH HEIGHT THIGKNE55 MATERIAL TYPE MATERIAL FIN15H IOIA 2 3'-011 7'-011 1-3/4" WOOD B HM PT GROUP 5 - IOIB 2 3'-011 71-011 1-3/4" WOOD A HM PT GROUP 5 5HERWIN WILLIAM5 102 2 31-011 7'-0" 1-3/411 WOOD A HM PT GROUP I PT -4 103 2 31-011 7'-011 1-3/4" WOOD A HM PT GROUP 2 4" HIGH 10q 1 31-011 71-011 1-3/411 WOOD A HM PT GROUP 3 IX6 PAINT GRADE 110 1 31-011 71-011 1-3/411 WOOD A HM PT GROUP 4 ITR 112 1 31-011 71-011 1-3/411 WOOD A HM PT GROUP 2 1 114 1 31-011 71-011 1-3/411 WOOD A HM PT GROUP I 115 1 31-011 -11-011 1-3/4" WOOD A HM PT GROUP I EXISTING 122 2 31-011 7'-011 1-3/4" WOOD A HM PT GROUP I PT -1 125 i 1 3'-0" 7'-0" 1-3/4" WOOD A HM PT GROUP I PT -I REMARKS: I. DOOR TO BE LOCKED FROM OUT5IDE 2. PROVIDE POCKET DOOR HARDWARE DOOR B FRAME TYPES N 111 C N C r r3 GENERAL NOTES: I. DOOR FRAMES TO BE PAINTED A5 SCHEDULED 2. STAIN INTERIOR WOOD DOORS, TYP. STAIN TBD 3. ALL DOOR HINGES AND HARDWARE TO BE SATIN NICKEL, TYP 4. ALL HM DOOR FRAMES TO BE PAINTED PT -2 3'-0" 0 FLU51-1 50LID GORE WOOD DOOR I O r FLU51H WOOD AND C6LA55 DOOR 2 HARDWARE LE6END GROUP 1 3 HINGES, CYLINDRICAL PASSAGE 4 STRIKE, DOOR STOP $ 51LENGER5 GROUP 2 3 HINGES, CYLINDRICAL OFFICE LOCK 4 STRIKE, DOOR STOP $ SILENCERS GROUP 3 3 HINGES, CYLINDRICAL REST ROOM LOCK 4 STRIKE, DOOR STOP $ 51LENGER5 GROUP 4 3 HINGES, CYLINDRICAL STOREROOM LOCK 4 STRIKE, DOOR STOP $ 51LENGER5 GROUP 5 3 HINGES, CYLINDRICAL ENTRY LOCK 4 STRIKE, DOOR STOP, 51LENGER5 $ GL05ER FINISH LE6END ITEM MANUFACTURER STYLE / COLOR FINISH DIM LOCATION LUXURY VINYL TILE LVT-I INTERFACE 5TYLE: LEVEL 5ET - TEXTURED WOOD6RAIN5 COLOR: A00425 GREY ADLER 25 GM X IM A5 SCHEDULED CONCRETE GONG -I I EXISTING SLAB PAINT TBD - - AS SCHEDULED 50LID SURFACE 5SM-1 WIL50NART ?EN GREY 811565 - - RECEPTION WINDOW PAINT PT -1 5HERWIN WILLIAM5 SW 7056 RESERVED WHITE SATIN - TYP WALL5 PT -2 5HERWIN WILLIAM5 5W 1056 RESERVED WHITE SEMI - DOOR FRAMES PT -3 5HERWIN WILLIAM5 5H"7056 RESERVED WHITE FLAT - 6WB GEILIN65 PT -4 SHERWIN WILLIAM5 5W 6500 OPEN SEAS SATIN - AGGENT WALLS RUBBER BASE RB -I NORA WALL BASE COTTON SEED - 4" HIGH A5 SCHEDULED WALL COVERIN6 WG -I MDG WALLGOVERIN6 PURATEGK AUSTERE COLOR: MDVIO65 GELADON - I WAITIN6 101 WOOD BASE "B -I IX6 PAINT GRADE PAINT TO MATCH WALL SEMI 611 HIGH WAITING IOI REMARKS: I. GG TO COORDINATE ALTERNATIVE: VALUE ENGINEERING FINISHES TO BE REVIEWED AND APPROVED BY OWNER., TYP NTERIOR ELEVATION 3/8" = 1 1-0 11 PAINT WALL AS 5GHEOULED PAINT L060 PT -I IN GLOSS WB -I, AS SCHEDULED s a s 1 m ROOM FIN 15H 5GHEDULE ROOM # DESCRIPTION FLOOR BASE WALL5 GEILIN65 MARKS NORTH SOUTH EAST WE5T MATERIAL HEIGHT 101 WAITING LVT-1 HB -I PT -1 PT -1 PT -1 PT -1 EXISTING EXI5TING 3 102 CONFERENCE LVT-I RB -I PT -1 PT -1 PT -1 PT -1 EXISTING V m EXISTING Ju 103 OFFICE LVT-I RB -I PT -1 PT -1 PT -I PT -1 EXISTING 0 EXISTING 104 ITR LVT-1 RB -I PT -1 PT -I PT -1 PT -1 EXI5TIN6 m EXISTING 105 ITR LVT-I RB -I PT -1 PT -1 PT -1 PT -I EXI5TING EXISTING 106 ITR LVT-I RB -I PT -1 PT -1 PT -I PT -1 EXISTING EXISTING 107 ITR LVT-I RB -I PT -1 PT -I PT -I PT -I EXISTING EXISTING 105 ITR LVT-I RB -I PT -1 PT -1 PT -1 PT -I EXISTING EXISTING loci GL05ET GONG -1 RB -I PT -1 PT -1 PT -1 PT -1 EXISTING EXISTING 2 110 IT / 5TORA6E GONG -1 RB -1 PT -I PT -1 PT -I PT -1 EXISTING EXI5TIN6 2 III HALL LVT-I RB -I PT -I PT -I PT -I PT -1 EXISTING EXISTING 112 ITR LVT-I RB -I WG -1 WG -1 WG -I WG -I EXI5TIN6 EXISTING 1 113 ITR LVT-I RB -I PT -1 PT -I PT -I PT -I EXISTING EXISTING 114 OFFICE LVT-I RB -I PT -1 PT -1 PT -1 PT -I EXISTING EXISTING 115 OFFICE LVT-I R13-1 PT -1 PT -I PT -1 PT -1 EXISTING EXISTING 116 OPEN LVT-I RB -1 PT -1 PT -I PT -I PT -1 EXISTING EXISTING 117 EXISTING REST ROOM - - - - - - EXISTING EXISTING 118 EXISTING REST ROOM - - - - - - EXISTING EXISTING Ilq LARGE TREATMENT LVT-I RB -I PT -1 PT -1 PT -1 PT -I EXI5TIN6 EXI5TIN6 120 LARGE TREATMENT LVT-I RB -I PT -I PT -I PT -1 PT -I EXISTING EXISTING 121 LARGE TREATMENT LVT-I R5-1 PT -I PT -1 PT -1 PT -1 EXI5TIN6 EXISTING 122 RECEPTION LVT-I RB -I PT -I PT -1 PT -I PT -I EXISTING EXISTING 123 SENSORY AREA LVT-I RB -I PT -I PT -I PT -I PT -1 EXISTING EXISTING REMARKS: I. PROVIDE PLYWOOD SUBSTRATE ON WALLS 2. PAINT EXISTING GONG TO REMAIN 3. REFER TO ELEVATION FOR ACCENT FINISHES 0 48" WIDE FRAMELESS PA55-THROU61-1 WINDOW WITH OT_.I A//GAIT MA11,1T AG INTERIOR EL.\/ATICN PAINT AS SCHEDULED BENETTIM055 LOGO CUSTOM DIMEN51ONAL LETTERIN6. CENTER ON CURVED WALL. WB -I, AS SCHEDULED ,ice HOTA DESIGNST M ILC INTERIOR DES*N 31 West Adams Street, Ste. 103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com IB -28001328 J 0 Z O � / O D O �. J = W m � V m Ju Q O J z ~ O� 0 J m REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HOTA DESIGN STUDIO, LLC OF F(0 � 961 9 DATE: 11-08-2019 FINISH & DOOR SCHEDULE & LEGEND, INTERIOR ELEVATIONS DRAWN BY: JC CHECKED BY: JC OAA PROJECT NO.: 19043.00 440 1 0A'1 PERMIT SET d CD 0 tr CL J J z 0 to N3 0 z m z 0 CC W a z W a W 0) W It CL X W O x F z 0 U Q 0 W IL W O 0 a W C0 z ¢ O D in r W O 2 LL 0 i= Ir W CL 0 Cr 0- W w X fl Q U) W LL O z W 2 Ir I.- (1) z z ¢ W Ir z W z O 10U z U) 0 Z L r fi C ILIN& PLAN i/4'" _ I' -o" I it jl 1111 _ M.A.PQKey Groo J} e 400fEILIN15 PLAN NOTES I. MECHANICAL, ELECTRICAL, PLUMBING FIRE PROTECTION AND STRUCTURAL ENGINEERING ARE NOT WITHIN 5GOPE OF SERVICE. ITEMS INDICATED ON PLAN FOR COORDINATION PURPOSES ONLY. REFER TO ELECTRICAL ENGINEERS DOCUMENT FOR LIGHTING SELECTIONS. 2. EXISTING ACOUSTIC CEILINGS TO REMAIN. UNLESS NOTED OTHERWISE 3. GG TO ALTER, REPAIR AND OR REPLACE EXISTING CEILING GRID AND TILES AS REQUIRED. 4. RELOCATE EXISTING LIGHTING AND CEILING DEVICES AS REQUIRED PER DE5167N INTENT. 5. LOCATE LIGHTING CENTERED IN ROOMS AS BEST AS POSSIBLE. 6. GC TO SALVAGE, RELOCATE AND REUSE EX15TINO LIGHT FIXTURES. IF NEW FIXTURES ARE REQUIRED, MATCH BUILDING STANDARDS. REPLACE ANY MISSING OR INOPERABLE LAMP5 AS REQUIRED. MATCH ALL COLOR TEMPERATURES. 1. REFER TO ELECTRICIANS DRAWINGS LIGHTING LAYOUT AND 5WITCHING LOCATIONS Mechanical Notes: BLOOM BEHAVIORAL Y.O. Box 1651 Monte Vedra Beach, FL 32004 (904)280-2266 �«»�.n�akell��roun.com CMC056690 Roof top package units a. RT1i-1 Carrier 50FC-A052B5 (4 Ton RTIT) b. RTIT-2 Carrier 50FC-A062B"- (5 Ton RT1T) c. RTU -3 Carrier 50FC A062B5 (5 Ton RTI') Reuse the existing supple and return air duct work and rework as necessary Install new supply & return air: taps, flex and grills for new offices 101,102,103,114,115 Bathroom Exhaust is existing and will remain. C�r1 �l y C7r ' It P.Q. Box 1651 Ponte Vedra Bch. FL 32004 - 904-280-2266 HC TA DE'SMSTUDID,I LC 31 West Adams Stnset, Stet 03 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com 6-2W,326 ..j oZ ` ? z _�- .c <oa0 W � V � 0 -� 0 I-- < < 0h J M REVISIONS: HIS DRAWING IS AN INSTRMW OF SERVICE AND IS THE ROPERTY OF ROTA DESIGN STUDIO, LLC AND R SHALL EVER BE REPRODUCED IN WHOLE OR IN PART WITHWT THE XPFESS WRf MN PERANSSION OF HOTA DESIGN SRM LLC r � Fys ��v ���MTERIOR�ti Jim w CAo DATE: 11-08-2019 REFLECTED CEILING PLAN DRAWN BY: JC CHECKED BY: is PROJECT NO.: 19043.00 Irl. PERMIT SET r 0 w m O a U J J O z (9 U) w 0 O m z 0 V) V) w a. z w F O w w w 0- x w D O E- z O U 0 0 a w O 0 w z Q U J J C 0 h z (9 V) w 0 O LL O F- w 0- 0 a w 0 z 4 w U w LL O I— z w tr U) z z Q w a z z O U 0 a m z 0 ELECTRICAL LEDGEND TOGGLE SWITCH - SINGLE POLE - QUIET TYPE 20 AMP, 120/277 VOLT HUBBELL NO. HBL12211 WITH NO. P1 COVERPLATE - 46" MOUNTING HEIGHT U.N.O. PROVIDE MOTION SENSOR SWITCH WHERE REQUIRED PER FL ENERGY CODE 415 TOGGLE SWITCH - 3 WAY - QUIET TYPE 20 AMP, 120/277 VOLT 3 HUBBELL NO. HBL32211 WITH NO. P1 COVERPLATE - 46" MOUNTING HEIGHT U.N.O. PROVIDE MOTION SENSOR SWITCH WHERE REQUIRED PER FL ENERGY CODE 415 WALL MOUNTED MOTION SENSOR SWITCH CEILING MOUNTED MOTION SENSOR, LOW VOLTAGE. PROVIDE POWER PACKS PER MANUFACTURES RECOMMENDATIONS PP LOW VOLTAGE POWER PACK FOR CEILING MOUNTED MOTION SENSOR SWITCH DUPLEX RECEPTACLE - 20 AMP, 120 VOLT, 3 WIRE GROUNDING, HUBBELL NO. 53521 WITH NO. P8 COVERPLATE, 18 INCH MOUNTING HEIGHT, U.N.O. 509 CONTROLLED RECEPTACLE INSTALLED IN ACCORDANCE WITH ASHRAE 90.1 Ir DUPLEX RECEPTACLE - SAME AS ABOVE EXCEPT MOUNTED ABOVE COUNTER, 42" MOUNTING HEIGHT, U.N.O. DOUBLE DUPLEX RECEPTACLES -(2) TWO 20AMP,120VOLT,3 WIRE GROUNDING, HUBBELL NO. 53521 WITH NO. P82 COVERPLATE, 18 INCH MOUNTING HEIGHT, U.N.O. ® 20GAMP, ANG F1200 VOLOR OTXDUPLEX R CWITH SEP ACLS R (1) DATA OUTLET AND (1) DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20 AMP, 120 VOLT, 3 WIRE GROUNDING. HUBBELL NO. GF53521A WITH NO. HPS11 COVERPLATE, 46 INCH MOUNTING HEIGHT, U.N.O. EXTERIOR LOCATIONS SHALL BE MOUNTED AT 18" A.F.F. DATA/TELEPHONE OUTLET - 4 INCH SQUARE JUNCTION BOX WITH 1 -GANG EXTENSION A RING, BLANK COVER PLATE - 18 INCH MOUNTING HEIGHT, U.N.O. PROVIDE 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE. Q JUNCTION BOX. MOTOR, FAN, PUMP OR AIR CONDITIONING UNIT. 0 LIGHTING AND/OR POWER PANEL.BOARD. WIRING IN CONDUIT OR MC CABLE, RUN CONCEALED ABOVE CEIUNG OR IN WALLS. HOMERUN TO PANELBOARD - NUMBER OF ARROWS DENOTES QUANTITY OF CIRCUITS. CROSSMARKS INDICATE QUANTITY OF NO. 12 CONDUCTORS. RUNS VOID OF CROSSMARKS ARE 1/2 INCH CONDUIT, 3 NO. 12, U.N.O. DO NOT COMBINE HOMERUNS EXCEPT AS SPECIFICALLY INDICATED ON THE PLAN. [:::p DISCONNECT SWITCH, "3 60/40 N3R" DENOTES 3 POLE, 60 AMPS, 40 AMPS FUSES N3R DENOTES DISCONNECT NEMA RATING. WP DENOTES WEATHERPROOF - MOUNT RECEPTACLES HORIZONTALLY AND PROVIDE TAYMAC 60350 COVERPLATE, FOR SWITCHES PROVIDE TAYMAC 40110 COVERPLATE. N/L DENOTES NIGHT LIGHT. DO NOT SWITCH WALL OPENING PROTECTIVE MATERIALS (CUV) AS TESTED TO ANSI/UL 263 1OR 2 HR RATING 1 OR 2 HR GYPSUM WAL ASSEMBLY (2 HR. SHOWI POWER CABLE 1/8" THICK CP6171CP617L FIRESTOP PUTTY PAD MIN. 2'x 4" WOOD STUD UL USIM NON-METALLIC OUTLET BOX (REFER TO UL LISTING) OR UL LISTED METALLIC OUTLET BOX (REFER TO UL LISTING) NOTE: WEHRE BOXES BACK UP TO ONE ANOTHER OR ARE VERY CLOSE TOGETHER IN THIS WALL, ADD A LAYER OF 5/8" TYPE "X" FIRECODE SCREWED TO STUD BETWEEN THEM CP617 PUTTY PADS, FOR USE WITH MAX 4 BY 4 IN. FLUSH DEVICE UL LISTED METALLIC OUTLET BOXS INSTALLED WITH STEEL COVER PLATES IN 1 AND 2 HR. FIRE RATED GYPSUM WALLBOARD WALL ASSEMBLIES FRAMED WITH MIN 3-1/2 IN. DEEP WOOD OR STEEL STUDS AND CONSTRUCTED AS SPECIFIED IN THE INDIVIDUAL U300 OR 0400 SERIES WALL AND PARTITION DESIGNS IN THE FIRE REISTANCE DIRECTORY. MIN 1/8 IN. THICK MOLDABLE PUTTY PADS ARE TO BE INSTALLED TO COMPLETELY COVER THE EXTERIOR SURFACES OF THE OUTLET BOX (EXCEPT FOR THE SIDE OF THE OUTLET BOX AGAINST THE STUD) AND COMPLETELY SEAL AGAINST THE STUD WITHIN THE STUD CAVITY WHEN MOLDABLE PUTTY PAD OUTLET BOX PROTECTIVE MATERIAL. IS USED ON BOXES ON BOTH SIDES OF WALL AS DIRECTED, THE HORIZONTAL SEPARATION BETWEEN OUTLET BOXES ON OPPOSITE SIDES OF THE WALL. MAY BE LESS THAN 24 IN. PROVIDED THAT THE BOXES ARE NOT INSTALLED BAC TO BACK. CP617 FIRESTOP PUTTY PADS, FOR USE WITH MAX 4 BY 3-3/4 BY 3 IN. DEEP UL LISTED NONMETALLIC OUTLET BOXES MANUFACTURED BY CARLON ELECTRICAL PRODUCTS, MADE FROM POLYVINYL CHLORIDE, AND BEARING A 2 HR. RATING UNDER THE " OUTLET BOXES AND FITTING CLASSIFICATION FOR FIRE RESISTANCE CATEGORY IN THE FIRE RESISTANCE DIRECTORY. PUTTY PADS AND BOXES FOR USE IN 1 AND 2 HR FIRE RATED GYPSUM WALLBOARD ASSEMBUESM, FRAMED WITH MIN 3-1/2 IN. DEEP WOOD STUDS AND CONSTRUCTED AS SPECIFIED IN THE INDIVIDUAL U30 SERIES WALL AND PARTITION DESIGNS IN THE FIRE RESISTANCE DIRECTORY. OUTLET BOX SECURED TO WOOD STUD BY MEANS OF TWO NAILING TABS SUPPLIED WITH THE OUTLET BOX. MIN 1 /8 IN. THICK MOLDABLE PUTTY PADS ARE TO BE INSTALLED TO COMPLETELY COVER THE EXTERIOR SEL AGAINST THE STUD WITHIN THE STUD CAVITY. OUTLET BOXES INSTALLED WITH STEEL OR PLASTIC COVER PLATES. WHEN MOLDABLE PUTTY PAD OUTLET BOX PROETECTIVE MATERIAL IS USED ON BOXES ON BOTH SIDES OF WALL AS DIRECTED, THE HORIZONTAL SEPARATION BETWEEN BOXES ON OPOSIfE SIDES OF THE WALL MAY BE LESS THAN 24 IN. PROVIDED THAT THE BOXES ARE NOT INSTALLED BACK TO BACK CP617 FIRESTOP PUTTY PADS, FOR USE WITH MAX 2-1/4 BY 3-3/4 BY 2-1/4 IN. DEEP UL LISTED NONMETALLIC OUTLET BOXES MANUFACTURED BY PASS AND SEYMORE INC., AND BEARING A 2 HR. RATIN UNDER THE* OUTLET BOXES AND FITTINGS CLASSIFICATION FOR FIRE RSISTANCE CATEGORY IN THE FIRE RESISTANCE DIRECTORY. PUTTY PADS AND BOXES FOR USE IN 1 AND 2 HR FIRE RATED GYPSUM WALLBOARD ASSEMBLIESM, FRAMED WITH MIN 3-1/2 IN. DEEP WOOD STUDS AND CONSTRUCTED AS SPECIFIED IN THE INDIVIDUAL U300 SERIES WALL AND PARITTIO DESIGNS IN THE FIRE RESISTANCE DIRECTORY. OUTLET BOX SECURED TO WOOD STUD BY MEANS OF TWO NAILING TABS SUPPLIED WITH THE OUTLET BOX. MIN 1/8 IN. THICK MOLDABLE PUTTY PADS ARE TO BE INSTALLED TO COMPLETELY COVER THE EXTERIOR SEAL AGAINST THE STUD WITHIN HE STUD CAVITY. OUTLET BOXES INSTALLED WITH STEEL OR PLASTIC COVER PLATES. WHEN MOLDABLE PUTTY PAD OUTLET BOX PROETECTIVE MATERIAL IS USED ON BOXES ON BOTH SIDES OF WALL AS DIRECTED, THE HORIZONTAL SEPARATION BETWEEN BOXES ON OPPOSITE SIDES OF THE WNW.. MY BE LESS THAN 24 IN. PROVIDED THAT THE BOXES ARE NOT INSTALLED BACK TO BACK CP617 FIRESTOP PUTTY PADS, FOR USE WITH MAX 4 BY 3-3/4 BY 3 IN. DEEP UL LISTED NONMETALLIC OUTLET BOXES MANUFACTURED BY ALLIED MOLDED PRODUCTS, INC., MADE FROM FIBER REINFORCED THERMOPLASTIC AND BEARING A 2 HR RATING UNDER THE " OUTLET BOXESAND FITTINGS CLASSIFICATION FOR FIRE RESISTANCE" CATEGORY IN THE FIRE RESISTANCE DIRECTORY. PUTTY PADS AND BOXES FOR USE IN 1 HR FIRE RATED GYPSUM WALLBOO RD ASSEMBLIESM, FRAMED WITH MIN 3-1/2 IN. DEEP WOOD STUDS AND CONSTRUCTED AS SPECIFIED IN THE INDMDAL U300 SERIES WALL AND PARTITION DESIGNS IN THE FIRE RESISTANCE DIRECTORY. OUTLET BOX SECURED TO WOOD STUD BY MEANS OF TWO NAILING TABS SUPPLIED WITH THE OUTLET' BOX. MIN 1/8 IN. THICK MOLDABLE PUTTY FADS ARE TO BE INSTALLED TO COMPLETELY COVER THE EXTEROR SEAL AGAINST THE STUD WITHIN THE STUD CAVITY. OUTLET BOXES INSTALLED WITH STEEL. OR PLASTIC COVER PLATES. WHEN MOLDAEU PUTTY PAD OUTLET BOX PROETECTIVE MATERIAL IS USED ON BOXES ON BOTH SIDES OF WALL AS DIRECTED, THE HORIZONTAL SEPARATION BETWEEN BOXE ON OPPOSITE SIDES OF THE WALL MAY BE LESS THAN 24 IN. PROVIDED THAT THE BOXES ARE NOT INSTALLED BACK TO BACK LIC 11 ® EXHAUST FAN - PROVIDED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICIAN INTEMOR DFWN 31 West Adams Street, Ste.103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com 16-26001326 i REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART W(THM THE EXPRESS VAZMN PMU-ZgM n[ unTA fYCVJd on uvn i. r DATE: 11-08-2019 LIGHTING PLAN DRAWN BY: JC CHECKED BY: JC OCCUPANCY DETECTOR WIRING DIAGRAM a,C� PROJECT NO.: 19043.00 NOTES: Fes, 1. THIS DIAGRAM AND ALL PART NUMBERS ARE BASED ON "WATTSTOPPER" PRODUCTS. 2. PROVIDE SENSORS IN ALL ROOMS AS REQUIRED BY FBC 13-415.1' ■ NOT TO SCALE E)LC WS570010 LIGHTING CONTROL DETAIL PERMIT SET N 0 C- z z < 0 LL- J M Q v m (�W L_L_I I— V 0 z~ U-) � <C 0 1 [-) i REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART W(THM THE EXPRESS VAZMN PMU-ZgM n[ unTA fYCVJd on uvn i. r DATE: 11-08-2019 LIGHTING PLAN DRAWN BY: JC CHECKED BY: JC OCCUPANCY DETECTOR WIRING DIAGRAM a,C� PROJECT NO.: 19043.00 NOTES: Fes, 1. THIS DIAGRAM AND ALL PART NUMBERS ARE BASED ON "WATTSTOPPER" PRODUCTS. 2. PROVIDE SENSORS IN ALL ROOMS AS REQUIRED BY FBC 13-415.1' ■ NOT TO SCALE E)LC WS570010 LIGHTING CONTROL DETAIL PERMIT SET ri W Co Ix Q_ U) J 0 w z 0 0 W 0 0 M M z 0 U) U) cr W CL z W 0 W W CL X W D 0 f- z 0 U D 0 a W 0 0 Q W C0 } z U J O 0 U) z 0 U) W 0 0 LL 0 W a- 0 W a W 0 z d W U W U) LL 0 z W z z d W d 10 P z W F_ z 0 U H 0 z _ a 0 z F - ELECTRICAL NOTES: 1. ELECTRICAL SERVICE AND INSTALLATION SHALL CONFORM TO THE 2014 EDITION OF THE NATIONAL ELECTRICAL CODE, APPLICABLE STATE AND LOCAL CODES AND LOCAL UTILITY COMPANY REQUIREMENTS 2. CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE SERVICE WITH THE UTILITY COMPANY PRIOR TO BID. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING LOCATIONS AND REQUIREMENTS OF TRANSFORMERS, POLES, SERVICE EQUIPMENT AND OBTAIN ALL NECESSARY APPROVALS FROM THE UTILITY COMPANY PRIOR TO COMMENCMENT OF WORK. UTILITIES SHOWN ON DRAWINGS ARE TO BE USED AS A GUIDELINE ONLY AND MAY NOT NECESSARILY BE APPROVED. FINAL APPROVALS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 3. CONTRACTOR SHALL COORDINATE ALL CONDUIT ROUTING WITH OTHER TRADES PRIOR TO ROUGH IN TO DETERMINE ROUTES THAT WILL NOT INTERFERE WITH OTHER TRADES. 4. CONNECT EXIT LIGHTS AND EMERGENCY BALLASTS OF FIXTURES DENOTED AS EMEGENCY TO UNSWITCHED LIGHTING CIRCUIT 5. ALL LIGHT FIXTURES SHALL BE MOUNTED AS CLOSE TO ADJACENT DOOR FRAME AS POSSIBLE 6. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES. REFER TO ARCHITECTURAL, MECHANICAL AND CIVIL DRAWINGS IN ORDER TO BE AWARE OF CONDITIONS AFFECTING ELECTRICAL WORK. 7. CONTRACTOR SHALL COORDINATE ALL MECHANICAL EQUIPMENT CONNECTIONS WITH MECHANICAL CONTRACTOR AND EQUIPMENT SUBMITTALS PRIOR TO ROUGH IN FOR EXACT LOCATIONS, CIRCUIT SIZES, AND BREAKER REQUIREMENTS. NOTIFY ARCHITECT OF ANY CHANGES TO CONTRACT PRICE IF WIRE SIZE INCREASES. 8. MECHANICAL CONTRACTOR TO PROVIDE BATH FANS AND RELAYS TO INTERLOCK AHU'S. 9. ALL CONDUIT TO BE SUPPORTED INDEPENDANT FROM CEILING GRID 10. EXAMINE EXISTING CONDITIONS PRIOR TO BID AND COMPARE WITH NEW WORK. REPORT ANY OBSERVED DESCREPANCIES. 11. ALL LIGHT SWITCHS SHALL BE INSTALLED PER FLORIDA ENERGY CODES. PROVIDE OCCUPANCY SENSORS OR DUAL SWITCHING AS REQUIRED. 12. A LICENSED ELECTRICIAN SHALL BE ONSITE AT ALL TIMES DURING ELECTRICAL INSTALLATION LGT/RECEPTACLE CONTROL DETAIL NOTES: 1. PROVIDE VACANCY SENSOR IN LOCATIONS INDICATED. INSTALL IN ALL OFFICE LOCATIONS PER ASHRAE 90.1 2. CONTRACTOR TO ADJUST SENSITIVITY LEVEL BASED ON ROOM SIZE AND FURNITURE LAYOUT, SET TIME OUT ON SENSOR TO 12 MIN. (ALL SENSORS MUST BE FIELD ADJUSTED, DONT INSTALL WITH FACTORY SETTING) PROVIDE SENSOR MASKING KIT AS REQUIRED 3. PROVIDE 20A., 24 VOLT RELAY IN AREAS INDICATED TO AUTOMATICALLY DISCONNECT 120 VOLT RECEPTACLE POWER WHEN NO OCCUPANCY IS DETECTED. RELAY SHALL BE MANUFACTURED BY SAME MANUFACTURER AS THE POWER PACK TO INSURE COMPATIBLE VOLTAGE AND POWER RATING REQUIRED TO CONTROL RECEPTACLE AS INDICATED 4. PROVIDE DUPLEX RECEPTACLES IN AREAS INDICATED WITH HALF—SWITCHED OUTLETS. OUTLETS SHALL EACH HAVE A PERMANENT LABEL INDICATING TOP HALF OF RECEPTACLES ARE CONTROLLED. 4. OPTIONAL LOW VOLTAGE WALL SENSOR CAN BE USED IF CEILING SENSOR IS NOT REQUIRED FOR ROOM COVERAGE. DELETE LOCAL SWITCH BETWEEN LGT RELAY PACK AND LGT. LOAD. EXISTING PANEL—A IT! STORAG; h 110=.r-- ♦` A— 2 j HALL 111 A-4 CLOSET 109 ITR 107 L� A-8 ITR ;106 ITR 105 Kj OFFICE 103 —10 SENSORY AREA 123 OFFICE 114 EXISTING PANEL -13 �FF10E 115 PP M P-4 EXISTI N' PANEL— EXISTING OPEN RESTROOM —�} 116 117 EXISTING RESTROOM 118 C-12 C-10 C-8 C_ 0 C - - RECEPTION 122, -,-WAITING 101 LRECE 2 i UTILITY 125 GROUP TREATMENT 119 GROUP TREATMENT _120 GROUP TREATMENT 121 C-2 WTA DESIGN STU KI LLC WTEMOR OEMN 31 West Adams Street, Ste.103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com 16-26001326 Local L Off Switch o Neutra! Wht Lgt Red Z a d Power 0 NOTE 5 Hot A IF Blk Pack Red � Q �W � Red Bk B u m W Neutral Wht RecP• Red zF-- Q I Power 0 o Hot BIR Pack Red 1 I 0 0-) M REVISIONS: Controlled Red 8k Blu Receptacle OPTIONAL WALL CONTROL Control Output NOTE 5 Any Note: Common 24VDC Maximum number of sensors per power Ceiling/Wall pack depends on the model of sensor. Sensor See the product data sheet to deter— I +24VDC _t= mine the specific current consumption of each sensor. NOT TO SCALE LGT/RECEPTACLE CONTROL DETAIL NOTES: 1. PROVIDE VACANCY SENSOR IN LOCATIONS INDICATED. INSTALL IN ALL OFFICE LOCATIONS PER ASHRAE 90.1 2. CONTRACTOR TO ADJUST SENSITIVITY LEVEL BASED ON ROOM SIZE AND FURNITURE LAYOUT, SET TIME OUT ON SENSOR TO 12 MIN. (ALL SENSORS MUST BE FIELD ADJUSTED, DONT INSTALL WITH FACTORY SETTING) PROVIDE SENSOR MASKING KIT AS REQUIRED 3. PROVIDE 20A., 24 VOLT RELAY IN AREAS INDICATED TO AUTOMATICALLY DISCONNECT 120 VOLT RECEPTACLE POWER WHEN NO OCCUPANCY IS DETECTED. RELAY SHALL BE MANUFACTURED BY SAME MANUFACTURER AS THE POWER PACK TO INSURE COMPATIBLE VOLTAGE AND POWER RATING REQUIRED TO CONTROL RECEPTACLE AS INDICATED 4. PROVIDE DUPLEX RECEPTACLES IN AREAS INDICATED WITH HALF—SWITCHED OUTLETS. OUTLETS SHALL EACH HAVE A PERMANENT LABEL INDICATING TOP HALF OF RECEPTACLES ARE CONTROLLED. 4. OPTIONAL LOW VOLTAGE WALL SENSOR CAN BE USED IF CEILING SENSOR IS NOT REQUIRED FOR ROOM COVERAGE. DELETE LOCAL SWITCH BETWEEN LGT RELAY PACK AND LGT. LOAD. EXISTING PANEL—A IT! STORAG; h 110=.r-- ♦` A— 2 j HALL 111 A-4 CLOSET 109 ITR 107 L� A-8 ITR ;106 ITR 105 Kj OFFICE 103 —10 SENSORY AREA 123 OFFICE 114 EXISTING PANEL -13 �FF10E 115 PP M P-4 EXISTI N' PANEL— EXISTING OPEN RESTROOM —�} 116 117 EXISTING RESTROOM 118 C-12 C-10 C-8 C_ 0 C - - RECEPTION 122, -,-WAITING 101 LRECE 2 i UTILITY 125 GROUP TREATMENT 119 GROUP TREATMENT _120 GROUP TREATMENT 121 C-2 WTA DESIGN STU KI LLC WTEMOR OEMN 31 West Adams Street, Ste.103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com 16-26001326 THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE DATE: 11-08-2019 DXPOWER PLAN POWER PLAN 4„ _ 1,_03 -, DRAWN BY: Jc CHECKED BY: JC PROJECT NO.: 19043.00 0 E�200 PERMIT SET N 0 ~ V) Z 0 Q0� � Q �W � v m W i- U 0 zF-- Q Z 0 0 1 0-) M REVISIONS: THIS DRAWING IS AN INSTRUMENT OF SERVICE AND IS THE DATE: 11-08-2019 DXPOWER PLAN POWER PLAN 4„ _ 1,_03 -, DRAWN BY: Jc CHECKED BY: JC PROJECT NO.: 19043.00 0 E�200 PERMIT SET EXISTING PANEL A FLUSH MTD. CIRCUIT BREAKER TYPE 120/208 VOLTS 3 PHASE 4 WIRE 225 AMP MAIN LUGS ONLY CKT NO. DESIGNATION LIGHTING LIGHTING CIRCUIT Q CIRCUIT BREAKER CKT KVA CIRCUIT KVA CIRCUIT BREAKER CIRCUIT DESIGNATION CKT NO. 2 WIRE COND POLE TRIP TRIP POLE COND WIRE 1 12 1/2 1 20 1.5 1.0 20 1 1 /2 12 RECEPTACLE 3 12 1/2 1 20 1.5 1.0 20 1 1/2 12 RECEPTACLE 4 5 4 1 UGHTING 12 1/2 1 1.0 20 1 1/2 12 RECEPTACLE 6 7 2 3 LIGHTING 12 1/2 1 1.0 20 1 1/2 12 RECEPTACLE 8 9 4 51.0 12 RECEPTACLE 10 12 14 11 1.0 20 1 1/2 12 RECEPTACLE 10 11 1 1/2 12 RECEPTACLE 13 12 13 15 14 15 16 17 16 17 18 19 18 19 20 21 20 21 22 23 22 23 24 25 24 25 26 27 26 27 28 29 28 29 30 31 30 31 32 33 32 33 34 35 JEXISTING WTH 10 3/4 2 30 4.5 34 35 36 37 1.3 20 36 37 F EXISTING RECEP 38 39 EXISTING RTU 6 1.0 20 1 1/2 12 EXISTING RECEP 38 39 EXISTING RTU 6 3/4 3 60 15.6 1.0 20 1 1/2 12 EXISTING RECEP ---] 40 41 12 EXISTING RECEP 42 TOTAL AMPS 140.8 1.0 20 1 1/72 12 EXISTING RECEP 42 TOTAL AMPS 73.9 6 TOTAL KVA 26.6 15.6 22,000 AMP. RMS. SYMMETRICAL 1/2 SHORT CIRCUIT CURRENT RATING 40 SHADED AREAS DENOTE EXISTING CIRCUITS z w it 0 w It a x w 0 z 0 I -- U 0 of a w ,r 0 Q z w } z Q U J J {j a H z t9 w Q t - O w O rr w a- 0 ix a w 0 z w U w U) LL 0 1-- z w M f- z 4 w tr Q z w z O U 0 z Q 0 3r'/Aur-L) ANLAJ U UNU I t tAiJ I INIJ UIHUUI I S TO METER CENTEF' EXISTING POWER RISER DIAGRAM NOT TO SCALE POWER RISER NOTES: 1. EXISTING TENANT METERS, FEEDERS, AND PANELS TO REMAIN 2. PROVIDE NEW TYPED PANEL SCHEDULE 3. TOTAL CONNECTED LOAD IS LISTED AT THE BOTTOM OF THE PANEL SCHEDULE EXISTING PANE C FLUSH MTD. CIRCUIT BREAKER TYPE 120/208 VOLTS 3 PHASE 4 WIRE 225 AMP MAIN LUGS ONLY EXISTING PANEL B FLUSH MTD. CIRCUIT BREAKER TYPE 120/208 VOLTS 3 PHASE 4 WIRE Q 225 AMP MAIN LUGS ONLY CKT DESIGNATION CIRCUIT K A CIRCUIT BREAKER KVA KVA CIRCUIT BREAKER WIRE CIRCUIT POLE DESIGNATION CKT N0. COND WIRE 1 LIGHTING 12 1/2 1 20 1.5 1.5 1.0 20 1 1/2 NO. WIRE COND POLE TRIP TRIP POLE COND WIRE 1.0 20 1 1/2 12 RECEPTACLE 4 1 UGHTING 12 1/2 1 20 1.5 1.0 20 1 1/2 12 RECEPTACLE 2 3 LIGHTING 12 1/2 1 20 1.5 1.0 20 20 1 1/2 12 RECEPTACLE 4 51.0 12 RECEPTACLE 10 12 14 11 1 1/2 12 RECEPTACLEm 6 7 1 1/2 12 RECEPTACLE 13 8 9 15 10 11 16 17 12 13 18 19 14 15 20 21 16 17 22 23 18 19 24 25 20 21 26 27 22 23 28 29 24 25 30 31 26 27 32 33 28 29 34 35 JEXISTING WTH 10 3/4 2 30 4.5 30 31 36 37 1.3 20 32 33 12 EXISTING RECEP 38 39 EXISTING RTU 6 3/4 3 60 15.6 1.3 20 34 35 12 EXISTING RECEP 40 41 1.5 20 1 1/2 12 EXISTING SIGN 36 37 12 EXISTING RECEP 42 TOTAL AMPS 140.8 1.0 20 1 1/2 12 EXISTING RECEP 38 39 EXISTING RTU 6 3/4 3 60 15.6 1.0 20 1 1/2 12 EXISTING RECEP 40 41 J 1.0 20 1 1 /212 EXISTING RECEP 42 TOTAL AMPS 7,'--5 TOTAL KVA 26.1 22,000 AMP, RMS. SYMMETRICAL SHORT CIRCUIT CURRENT RATING 3r'/Aur-L) ANLAJ U UNU I t tAiJ I INIJ UIHUUI I S TO METER CENTEF' EXISTING POWER RISER DIAGRAM NOT TO SCALE POWER RISER NOTES: 1. EXISTING TENANT METERS, FEEDERS, AND PANELS TO REMAIN 2. PROVIDE NEW TYPED PANEL SCHEDULE 3. TOTAL CONNECTED LOAD IS LISTED AT THE BOTTOM OF THE PANEL SCHEDULE EXISTING PANE C FLUSH MTD. CIRCUIT BREAKER TYPE 120/208 VOLTS 3 PHASE 4 WIRE 225 AMP MAIN LUGS ONLY CKT N0. DESIGNATION CIRCUIT Q CIRCUIT BREAKER KVA K A CIRCUIT BREAKER CIRCUIT DESIGNATION CKT NO. WIRE COND POLE TRIP TRIP POLE COND WIRE 1 LIGHTING 12 1/2 1 20 1.5 1.5 1.0 20 1 1/2 12 RECEPTACLE 2 3 LIGHTING 12 1/2 1 20 1.0 20 1 1/2 12 RECEPTACLE 4 5 w 1.0 20 1 1/2 12 RECEPTACLE 6 7 1.0 20 1 1/2 12 RECEPTACLE 8 9 1.0 20 1 1/2 12 RECEPTACLE 10 12 14 11 1.0 20 1 1/2 12 RECEPTACLE 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 JEXISTING WTH 10 3/4 2 30 4.5 36 37 1.3 20 1 1/2 12 EXISTING RECEP 38 39 EXISTING RTU 6 3/4 3 60 15.6 1.3 20 1 1/2 12 EXISTING RECEP 40 41 1.0 20 1 1/2 12 EXISTING RECEP 42 TOTAL AMPS 140.8 TOTAL KVA 50.7 22,000 AMP. RMS. SYMMETRICAL SHORT CIRCUIT CURRENT RATING .3nrsucu rr1 C^0 ur-Nu I t r-Aiz i irlu ultF ;UI l ti E-111/7NO HOTA DESM STUOKO LC 31 West Adams Street, Ste. 103 Jacksonville, FL 32202 P: 904.632.4800 www.hotadesign.com IB -26001326 I Q N n--*, r-- 0 V) : O QO M Q LLJ O z~ Q Z O C 1 crn M REVISIONS: THIS DMWING IS AN INSTRUMENT OF SERVICE AND IS THE PROPERTY OF HOTA DESIGN STUDIO, LLC AND IT SHALL NEVER BE REPRODUCED IN WHOLE OR IN PART MTHOUT THE EXPRESS WRITTEN PERMSSION OF ROTA DESIGN STUDIO, LLC utA I c: -11-Uta-zU 19 ELECTRICAL RISER AND PANEL SCHEDULES DRAWN BY: JC CHECKED BY: JC PROJECT NO.: 19043.00 O� PERMIT SET NIM016- 4, 40-- 2 O d' 1 O r z 0 co w a } m z 0 U) Ir w a w a z Q J J O r z C9 ul Lu a Q r 0 LL 0 it w CL 0 Ir 0- w w r D z Q w U o: w u- 0 0 r z uj Ir r co z Z w 10 1-- z III r O U 10Q Z 0 z r I� l D L Y°'1 3 G r( ii w'. i D A .7 A'71— /11-`7 I %sd, �l %i I w fam I lw/ N If 1/411 I[—off FMITURE PLAN NOTES I. MECHANICAL, ELECTRICAL, PLUMBING FIRE PROTECTION AND STRUCTURAL ENGINEERING ARE NOT WITHIN 56OPE OF SERVICE AND SHALL BE PROVIDED BY OTHERS. 2 FURNITURE SHOWN FOR COORDINATION OF ELECTRICAL AND DATA LOGATION5. 3. ELECTRICAL AND DATA SYMBOLS LOCATED FOR COORDINATION PURPOSES ONLY. REFER TO ELECTRICIANS DOGUMENT5 4. LOCATE HALL MOUNTED TV'5 ,@ 60" A.F.F., TYP. LOCATE ELECTRICAL / DATA / AND GABLE BEHIND TV 5. HHERE MILLWORK 15 TO BE LOCATED, PROVIDE OUTLETS ABOVE COUNTER TOP AND SPLASH 6. GC TO VERIFY HITH OWNERS FUTURE LOCATIONS OF APPLIANGE5 AND OR EQUIPMENT FOR ELECTRICAL NEEDS SYMBOL LE650 ELECTRICAL OUTLET D'— DATA OUTLET --pp HALL MOUNTED TV HMA DESM STlIIOK� I.1.IC WJTFt*SIGN 31 West Adams Street, Ste.103 JacksornriNe, FL 32202 P: 904.632.4800 www.hotadesign.com 0-26MI-126 REVISIONS: THIS DRAwMG IS AN IN.4TRLww OF SERVICE AND IS THE PROPERTY OF HOTA DESM SnW, LLC AND IT SHALL NEVER BE WPROOL CEO IN WHOLE OR N PART MHOLIT THE EXPRESS wwTEN PERMISSION OF HOTA DESIGN STuDio, LLC DATE: 11-08-2019 FURNITURE PLAN DRAWN BY: ,c CHECKED BY: ,c 0)PROJECT NO.: 19043.00 �, �0 opo p4qmb PERMIT SET r• 0 t � V I Z Z � 0 Q m V LLJ � AMMON) V m ....JZ H v -� o g 0 <ocm ON ..i M REVISIONS: THIS DRAwMG IS AN IN.4TRLww OF SERVICE AND IS THE PROPERTY OF HOTA DESM SnW, LLC AND IT SHALL NEVER BE WPROOL CEO IN WHOLE OR N PART MHOLIT THE EXPRESS wwTEN PERMISSION OF HOTA DESIGN STuDio, LLC DATE: 11-08-2019 FURNITURE PLAN DRAWN BY: ,c CHECKED BY: ,c 0)PROJECT NO.: 19043.00 �, �0 opo p4qmb PERMIT SET Revision Request/Correction to Comments **ALL INFORMATION ._. -:::51, :!-:1:4;, HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. 'V '3800 Seminole Rd, Atlantic Beach, FL 32233 J „''n- Phone: (904) 247-5826 Email: Building-Dept@coab.usPERM Z ^ --� 000 2_, ❑ Revision to Issued Permit OR j Corrections to Comments Date: //2 7126 Project Address: /O / 164 (. I L) ) , O‘A.lk (Z.. 4.(c- Contractor/Contact Name: J44 (.,imii-f�je."�,' Contact Phone: /)' 8- 67--* 76 5 Email: CC/6-LE. 166 7 %'f& c- 7 3 ....) Description of Proposed Revision/Corrections: esu, 10 CMGs' ii,l..._ate)(......L4:7;,,„,k I I CO EEk0.vi`of~w( SoloTl(:n S' '------D- --7 I J C` LIG affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • W• proposed revision/corrections add additional square footage to original submittal? No ❑ Yes (additional s.f. to be added: ) • W. proposed revision/corrections add additional increase in building value to original submittal? No ❑*yes (additional increase in building value: $ ) (Contractor must sign if increase in valuation) *signature of Contractor/Agent: (Office Use Only) �{ NV-Approved ❑ Denied ❑ Not Applicable to Department Permit Fee Due$ Cly Revision/Plan Review Comments Department Review Required: KBuilding._ Planning&Zoning Reviewed By Tree Administrator Public Works Public Utilities O 1 ` 3O c2-62-0 Public S.afety„ Date ire Services Updated 10/17/18 INTERIOR DESIGN 31 West Adams Street,Suite 103 • Jacksonville, FL 32202 w;. P: 904.632.4800 www.hotadesign.com HO-iiDESIGN STUDIO IB 26001326 Jose Cardenas, IIDA Transmittal Principal Interior Designer 31 West Adams Street, Ste. 103 Jacksonville, Florida 32202 PROJECT NUMBER: 19043.00 : 904.632.4800 : 321.698.7358 DATE: JANUARY 24, 2020 TO: FOR: Jake Chamberlin Vice President Building Review Comments—Bloom Behavioral Solutions Duckworth Construction 844 Whitlock Avenue, Suite 200 Jacksonville, Florida 32211 WE ARE SENDING YOU: ❑ Attached ❑ Under Separate Cover Z Original Drawings ❑ Change Order ❑ Samples ❑ Specifications ® Prints ❑ Disk ❑ Shop Drawings ❑ Sepia ❑ Other TRANSMITTED: ❑ As Requested ® For Your Use ❑ For Approval VIA: t INTERIOR DESIGN 44 31 West Adams Street,Ste.103 • Jacksonville,FL 32202 P:904.632.4800 I www.hotadesign.com HOTA DESIGN STUDIO 16:26001326 MEMO DATE: January 23, 2020 TO: TBD FROM: Jose Cardenas PROJECT: Bloom Behavioral Solutions PROJECT NO: 19025.00 RE: Application No: Comm 20-0002 REMARKS: Please find responses to the plan review comments for the project referenced above... Returned for Corrections: The plans submitted for review have been returned for corrections. Please correct and or provide the additional requested information to obtain plans approval. When resubmitting corrected sheets, provide a type written itemized narrative letter responding to our comments and directing the plans reviewer to the sheets the changes have taken place. FAILURE TO SUPPLY RESPONSE LETTER"WILL"RESULT IN A RETURNED FOR CORRECTIONS PERMIT STATUS. Revised sheets should be clouded, clearly showing areas were changes or corrections have occurred and re-inserted with the original set of drawings with old sheets removed. Unbound plans will not be reviewed. If this is an electronic submission please make sure that written narrative is submitted under correspondence along with a "complete set"{not just the revised sheets) of electronic documents. When submitting electronic plans, each discipline shall upload a single PDF file containing multiple sheets rather than separate PDFs for each sheet. Please re-upload in this fashion. 1. Life Safety Floor Plan: The City of Jacksonville's Fire Marshal's Office requires the submittal of a Life Safety Floor Plan for building permits for all new construction and existing building alterations in order to ascertain if occupancy is currently code compliant and to assist fire inspector in performing Life Safety Inspections. Please provide a Life Safety Plan to include all the following information on one page. If Life Safety Plan was submitted and you are receiving this comment, it means that all of the required info listed below was not included in your original submittal. It is understood that all listed items may not apply in your situation. Please refer to G002"Travel Distance Plane. Required Occupant Load Calculation: • Provide design occupant load using table 7.3.1.2 of NFPA 101 2015 edition.Area calculations should be shown with graphic seating configurations or fixtures in order to substantiate occupant load chosen. to Revised Building Summary, Occupants & Exits Table on Sheet G002. Exit Locations: • Designate main entrance and all secondary exits. All required exits shall terminate at a"public way". Access to the public way shall be accessible and must be via a stable, firm, and slip resistant conveyance such as a concrete sidewalk with a min. 5'x5' landing and 44"walkway. Multi story buildings should Page 2 1/23/2020 designate area of rescue with required communication means. Separation of exits using the one half (non-sprinkled) or one third (sprinkled)the diagonal distance rule should be shown on plans. defer to exit locations identified in Inc Travel Distance Han on Sheet G002 Required Egress Capacity: • Egress inches for means of egress components (doors. stairs, etc.) Refer to Occupancy & General Building Requirements Table of Sheet G002 Required measurements: (Worst case only need be shown.) • Dead end corridors measurements. None provided • Common path of travel measurements. 45'-0" (Refer to G002 "Travel Distance Plan".) • Total travel distance to exits. 65'-0" (Refer to G002 "Travel Distance Plan".) Required separation: • Show all fire barriers, smoke barriers, and smoke partitions. All rated walls per new directive from building official wall detail needs to include UL listing and needs to confirm by architect or engineer as being accurate. Tenant separation partitions are existing. GC to confirm rating. Required Lock Latch details: • Lock/Latch details: Panic Hardware, Thumb turn lock, Key Lock with indicator and required signage. Shall provide. Existing Rear exits are equipped with Panic Hardware. Required Electrical Stop/Disconnect Details: • Any required Emergency stops or Shunt trips. Please refer to Electrical Sheets provided by GC • Main Electrical disconnects access/location. Please refer to Electrical Sheets provided by GC Required markings of means of egress: • Exit signs to include tactile exits signage. Shall provide per NFPA 101.7.10.1.3 Required fire extinguisher Locations: • Locations per NFPA 10. Shall provide Required Emergency lighting: • Show emergency illumination. Please refer to Electrical Sheets provided by GC Required Lightweight Truss Signage: Location of lightweight truss signage per FAC 69A-60.0081 (if applicable). Please see below for clarification to requirement. http://www.coj.net/Departments/Planning-and-Development/Docs/Building-Inspection-Division/bulletin-f- 01-09- light-weight-truss-rule.aspx. N/A Page 3 1,23 2020 2. Key Plan: Provide key plan of building showing adjacent occupancy type with required separation of occupancies per 6th Edition FFPC, NFPA 101 Table 6.1.14.1.4. To clarify, the adjacent occupancy types are Group B business. Refer to Vicinity Plan located on Sheet G001. (BUSINESS TO MERCANTILE) IS 2 HR WALL 3. EXIT SIGN AND EMERGENCY LIGHT