Loading...
1021 Atlantic Blvd 953-975 COMM20-0022 New ATMOWNER:ADDRESS:CITY:STATE:ZIP: EQUITY ONE ATLANTIC VILLAGE INC 1600 NE MIAMI GARDENS DR NORTH MIAMI BEACH FL 33179 COMPANY:ADDRESS:CITY:STATE:ZIP: SECURITY VAULT WORKS INC 122 LAFAYETTE AVE LAUREL MD 20707 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 177602 0040 SECTION LAND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1021 ATLANTIC BLVD 953- 975 COMMERCIAL NEW COMMERCIAL install new ATM island $44600.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 6/30/2020 PERMIT NUMBER COMM20-0022 ISSUED: 6/30/2020 EXPIRES: 12/27/2020 COMMERCIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $275.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $137.50 CROSS CONNECTION 400-0000-343-3701 0 $50.00 PU REVIEW COMMERCIAL BLDG 001-0000-329-1007 0 $75.00 PW REVIEW COMMERCIAL BLDG 001-0000-329-1004 0 $150.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.19 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.13 ZONING REVIEW COMMERCIAL AND INDUSTRIAL USES 001-0000-329-1003 0 $350.00 TOTAL: $1,047.82 2 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 3 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 4 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: 2 of 2Issued Date: 6/30/2020 PERMIT NUMBER COMM20-0022 ISSUED: 6/30/2020 EXPIRES: 12/27/2020 COMMERCIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $1,047.82 COMM20-0022 Address: 1021 ATLANTIC BLVD 953-975 APN: 177602 0040 $1,047.82 BUILDING $275.00 BUILDING PERMIT 455-0000-322-1000 0 $275.00 BUILDING PLAN REVIEW $137.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $137.50 PUBLIC UTILITIES $50.00 CROSS CONNECTION 400-0000-343-3701 0 $50.00 PUBLIC UTILITIES PLAN REVIEW $75.00 PU REVIEW COMMERCIAL BLDG 001-0000-329-1007 0 $75.00 PUBLIC WORKS PLAN REVIEW $150.00 PW REVIEW COMMERCIAL BLDG 001-0000-329-1004 0 $150.00 STATE SURCHARGES $10.32 STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.19 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.13 ZONING PLAN REVIEW $350.00 ZONING REVIEW COMMERCIAL AND INDUSTRIAL USES 001-0000-329-1003 0 $350.00 TOTAL FEES PAID BY RECEIPT: R12199 $1,047.82 Printed: Tuesday, June 30, 2020 9:28 AM Date Paid: Monday, June 29, 2020 Paid By: SECURITY VAULT WORKS INC Pay Method: CHECK 136203 1 of 1 Cashier: LE Cash Register Receipt City of Atlantic Beach Receipt Number R12199 Building Permit Application City of Atlantic Beach Building Department 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us Updated 10/9/18 **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Job Address: l'f53 /JtI;:)Il~t-i3/v~ Permit Number: _________ _ Legal Description iJ4chiJVi? Efu"K,., RE# [7 7rep'~ -(?/CitJ> Valuation of Work (Replacement Cost) $ 'iLJ, ht!tJ Heated/Cooled SF d//} Non-Heated/Cooled 05"Sjf.1 • Class of Work: ~ew DAddition ~Iteration DRepair '¢Move DDemo DPool DWindow/Door 'IJ/) U f . . / d () ,Ic . I DR'd . I /J1t:iiJ,r.fv. fr/ff') ty1~h·"'<... I I • se 0 eXisting propose structure s: ~ ommercla eSI entia Ill, () I' I I '" oL J r-c::t-l $<.: • c> rt' 61<'110.J-~NTO TCJ 17<:' • If an existing structure, is a fire sprinkler system installed?: DYes 'tiN 0 L) Florida Product Approval # __________________ for multiple producJ:s use product approval form,R. x1/J C'/c/ $.'<n"'~-rl-I;)Y G-:;!~:;::;c Property Owner Information / I ,., /-rr-w~ NameLdz(Aev.~ @AV-~ JIVe//S. c;.~ Address PCJ.6o~· Zt:.OCJ CityC):,rhbif State eFT Zip 920 I r5 Phone---'~~A"'"fI"J'__ ________ _ E-Mail alA Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) __________________ _ Contractor Information Qualifying Agent ';;-Oy/)A ~ Elk)( City L;Jh~ I S~te,/YK? Zip ",?a7 0 7 Name of Company ,,5c:C(/(',£/ V4t-L 1i-L.)OV;;"$ II"(;. Address /z z. o. "t!"/h1"fA/ ,i)V<.. Office Phone ",:>0 (~ 35"'''' --ZL/9</ Job Site Contact Number ______________ _ State Certification/Registration # Cf,~· \ 1..Si3S'55 Architect Name & Phone # -,,/ ( E-Mail \ '4) SVW I file. . rr-.. cr7 Z--c: -0<'/2,0 Engineer's Name & Phone # _----:..-_L/Y=-.L/.D.&~ __ :__----------------------- Workers Compensation Insurer hI';ji?:a .do/k",-A~t/H'?L<--'?~t:pR Exempt 0 Expiration Date Z -, -Zo~ I Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTOR)!}>, BEFO .. RE REC ,IN .' NO I E OF COMMENCEMENT. vC ~ (Signature of Contractor) [~SOnaIlY Known 0 [ 1 Produced Identificati.---.......... ------' [~SOnally Known 0 [ 1 Produced Identificat.ft'm'--..... --~.:_. __ ....I Type of Identification: ____________ _ Type of Identification: ____________ _ Developer/Applicant/Designer: Matt Kiger Security Vault Works 2007 Gateway Boulevard Charlotte, NC 28208 704-399-4166 Ext. 1503 N Scale: NOT TO SCALE Schedule of Drawings Site Location Map Wells Fargo - Atlantic Beach REMOTE DRIVE-UP ATM INSTALLATION CONSTRUCTION DOCUMENTS Local Address: 983 Atlantic Boulevard Atlantic Beach, Florida 32233 Building Codes: 2017 Florida Building Code, 6th Edition 2014 National Electrical Code James M. Hamill ARCHITECT 580 Decker Drive Suite 170 Irving, Texas 75062 Phone 972/714.0420 Fax 972/714.0282 GENERAL C.1 - Cover Sheet ARCHITECTURAL Building Construction Type: 2B Unprotected non-combustible A.1 - Plans and Elevations A.2 - Details A.3 - Details A.4 - Details 2007 Gateway Blvd Charlotte, NC 28208 Phone 704/399.4166 Fax 704/399.4355 Copyright Security Vault Works, Incorporated c Cad File Name: P6379 Atlantic Beach SVW Project Number: 18-19-0010 Drawing Number: Date: Drawn By: Revisions: 2 3 4 Works, Incorporated. appropriate compensation to Security Vault except by agreement in writing and with on other projects or extensions to this project or not. They are not to be used by the owner project for which they are made is executed Vault Works, Incorporated whether the and shall remain the property of Security specifications as instruments of service are All rights reserved. Designs, drawings and 1 security vault works Phone 972/714.0420 Fax 972/714.0282 Irving, Texas 75062 580 Decker Drive Suite 170 James M. Hamill ARCHITECT We l l s F a r g o B a n k - A t l a n t i c B e a c h 98 3 A t l a n t i c B o u l e v a r d At l a n t i c B e a c h , F l o r i d a 3 2 2 3 3 2007 Gateway Blvd Charlotte, NC 28208 Phone 704/399.4166 Fax 704/399.4355 1714 Rotary Dr. Humble, TX 77338 05/01/2020 BPL Pl a n s a n d E l e v a t i o n s A.1 Copyright Security Vault Works, Incorporated c Cad File Name: P6379 Atlantic Beach SVW Project Number: 18-19-0010 Drawing Number: Date: Drawn By: Revisions: 2 3 4 Works, Incorporated. appropriate compensation to Security Vault except by agreement in writing and with on other projects or extensions to this project or not. They are not to be used by the owner project for which they are made is executed Vault Works, Incorporated whether the and shall remain the property of Security specifications as instruments of service are All rights reserved. Designs, drawings and 1 security vault works Phone 972/714.0420 Fax 972/714.0282 Irving, Texas 75062 580 Decker Drive Suite 170 James M. Hamill ARCHITECT We l l s F a r g o B a n k - A t l a n t i c B e a c h 98 3 A t l a n t i c B o u l e v a r d At l a n t i c B e a c h , F l o r i d a 3 2 2 3 3 2007 Gateway Blvd Charlotte, NC 28208 Phone 704/399.4166 Fax 704/399.4355 1714 Rotary Dr. Humble, TX 77338 05/01/2020 BPL Pl a n s a n d E l e v a t i o n s A.2 Baptist Health Remove all (E) Equipment and save for reinstallation (E) Concrete to be removed by Others (E) Painted Striping to be removed by others (E) NCR 6688 ATM w/ WFB3886 (E) Bollards x6 (E) Light Pole x2 (E) Clearance Bar (E) Concrete Island 4'-2"(N) Concrete Island (N) Concrete Island and gutter by others (N) Clearance Bar (N) NCR 6688 DU ATM (N) 4" Traffic Bollard x6 (N) Light Pole (E) Light Pole to be removed and relocated by others (N) Drive Lane by others (E) Light pole relocated by others 6" C L E A R . 8' - 0 " F O R 1 7 ' P O L E LI G H T B E L O W F I N I S H E D G R A D E #3 T I E S @ 1 2 " O . C . 3- # 3 T I E S @ 8 " O . C . 6" 36 " M A X . 12 " M I N . 6" CLR.EQ. Copyright Security Vault Works, Incorporated c Cad File Name: P6379 Atlantic Beach SVW Project Number: 18-19-0010 Drawing Number: Date: Drawn By: Revisions: 2 3 4 Works, Incorporated. appropriate compensation to Security Vault except by agreement in writing and with on other projects or extensions to this project or not. They are not to be used by the owner project for which they are made is executed Vault Works, Incorporated whether the and shall remain the property of Security specifications as instruments of service are All rights reserved. Designs, drawings and 1 security vault works Phone 972/714.0420 Fax 972/714.0282 Irving, Texas 75062 580 Decker Drive Suite 170 James M. Hamill ARCHITECT We l l s F a r g o B a n k - A t l a n t i c B e a c h 98 3 A t l a n t i c B o u l e v a r d At l a n t i c B e a c h , F l o r i d a 3 2 2 3 3 2007 Gateway Blvd Charlotte, NC 28208 Phone 704/399.4166 Fax 704/399.4355 1714 Rotary Dr. Humble, TX 77338 05/01/2020 BPL De t a i l s A.3 26'-6" 2'-8"2'-11"5'-5"4'-7"10'-11" 9"2'-3" 6" 9' - 0 " 3' - 6 " 8' - 8 " 6'-0" 17 ' - 0 " (N) Clearance Bar 9' - 4 " (N) Light Pole (N) Light Standard x4 (N) 4" Bollard x6 (N) NCR 6688 (N) WFB3885 Kiosk (N) Concrete Pad 4" 6" 10 " 4'-7"2'-0"3'-2"8'-7"8'-2" 5' - 2 " 8' - 0 " 1' - 8 " 2' - 6 " Copyright Security Vault Works, Incorporated c Cad File Name: P6379 Atlantic Beach SVW Project Number: 18-19-0010 Drawing Number: Date: Drawn By: Revisions: 2 3 4 Works, Incorporated. appropriate compensation to Security Vault except by agreement in writing and with on other projects or extensions to this project or not. They are not to be used by the owner project for which they are made is executed Vault Works, Incorporated whether the and shall remain the property of Security specifications as instruments of service are All rights reserved. Designs, drawings and 1 security vault works Phone 972/714.0420 Fax 972/714.0282 Irving, Texas 75062 580 Decker Drive Suite 170 James M. Hamill ARCHITECT We l l s F a r g o B a n k - A t l a n t i c B e a c h 98 3 A t l a n t i c B o u l e v a r d At l a n t i c B e a c h , F l o r i d a 3 2 2 3 3 2007 Gateway Blvd Charlotte, NC 28208 Phone 704/399.4166 Fax 704/399.4355 1714 Rotary Dr. Humble, TX 77338 05/01/2020 BPL De t a i l s A.4 GENERAL ELECTRICAL NOTES: 1. ALL WORK IS TO BE COORDINATED WITH THE REPRESENTATIVE. 2. FOR ELECTRICAL DETAILS REFER TO MANUFACTURER DRAWINGS AND SPECIFICATIONS. 3. CONTRACTOR SHALL FURNISH AND INSTALL 2" CONDUIT FOR ELECTRICAL SERVICE FROM POWER SOURCE TO ATM. PROVIDE THE FOLLOWING POWER CIRCUITS PER ATM: CKT1: DEDICATED/ISOLATED GROUND 20-AMP CIRCUIT (SINGLE-PHASE) for WU ATM and DEDICATED/ISOLATED GROUND 30-AMP CIRCUIT (SINGLE-PHASE) for DU CKT2: STANDARD 20-AMP CIRCUIT (FOR ENCLOSURE OR SIGNAGE). 4. CONDUIT FOR LOW-VOLTAGE DEVICES AT THE ATM IS TO BE 3/4" MINIMUM. THIS MUST BE A STRAIGHT RUN (WHENEVER POSSIBLE) DIRECTLY TO THE PHONE CLOSET. DATA CABLE MAY SHARE A CONDUIT WITH THE ALARM/CAMERA WIRING. 5.THE DATA CABLE USED FOR THE ATM IS CATEGORY "5". THREE (3) CABLES ARE REQUIRED FOR ALL ATMS 6. LABEL BOTH ENDS OF EACH STATION CABLE, CLEARLY IDENTIFYING IS CABLE NUMBER ("A" AND CABLE NUMBER). 7. WIRING FOR THE SECURITY DEVICES IS TO BE: ALARM: ONE 8 CONDUCTOR, 22 GAUGE UNSHIELDED CABLE FRAUD CAMERA: CAT6 SURVEILLANCE CAMERA: 18-2 AWG & CAT6 8. CONDUIT TO TELCO FOR LOW-VOLTAGE ITEMS IS NOT REQUIRED FOR OFFSITE ATMS WHERE ALARM/CAMERA SYSTEMS WILL BE LOCATED IN THE ATM. Inside bank to Electrical and Telco Location Reuse (E) Power and Low Voltage run from ATM to Branch