Loading...
1721 Atlantic Beach Dr RES19-0244 Survey, Form Board, Termite Notice of Treatment Applicator: Florida Pest Control • (www.flapest .com) Address: _- City _ Phone Site Location: Subdivision Lot # Block# Permit # Address Product used Active Ingredient % Concentration ❑ Premise Imidacloprid 0.1% ❑ Termidor Fipronil 0.12% ❑ i Type treatment: C�Soil Area Treated Square feet Linear feet Gallons Applied As per Florida Building Code— If soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. If this notice is for the final exterior treatment, initial this line Date Time Print Technician's Name Remarks: Applicator White Permit File -Canary Permit Holder- Pink 5/15O c PERMIT # Rgf o fq ©a Blower Door Test Services 904-209-7201 1093 A1A Beach Blvd#305 St. Augustine, Florida 32080 BLOWER DOOR TEST FORM Job Information Jurisdiction - Builder: J I en8 - NI-It7/atJ Li. C Community: Lot#: Address: 1 1 o� 1 Tt 9 r-rr/C P tE/4&l- D2 Unit#: City, State, Zip: P 7 LA '1 L 8� l-GfC C L 3 z L 13 Air Infiltration Test Results CFM(50) = d 1C' Volume= ciq a3 oa ACH(50)=CFM(50) x 60/Volume= When ACH(50)is less than 3,Mechanical Ventilation installation must be verified by building department. Pass Fail Passing results must be 7ACH(50) or less Certification of Test Results R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in section 553.993(5)or(7),F.S.or individuals licensed as set forth in Section 489.103(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Authorized Third Party I hereby certify the above results and that I hold the below certification: Class A or B A/C contractor or Mechanical contractor License No. RESNET approved HERS Rater or Residential Field Inspector Certification No. X BPI approved Building Analyst, Energy Auditor& IDL Certification No. 5061012 Professional Engineer License No. Mechanical ventilation has been adrd: Yes No �Di Signature: = L Date- q moi'•Printed Name: Richard Job Page 2 of 2 MAP SHOWING SURVEY OF LOT 28 OF ATLANTIC BEACH COUNTRY CLUB, UNIT TWO AS RECORDED IN PLAT BOOK 67, PAGES 132, 133, 134, 135, 136, & 137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA CERTIFIED TO: Gregory Nelson and Marcy DeWalt Nelson Ameris Bank Gibraltar Title Services Old Republic National Title Insurance Company LOT 27 EXIST. RESIDENCE F.F.EL.=(11.2)P S32'41'16"E 75.00' •CATV co (10.1)P (8.6)P ° ov (9.6)E (8.5)E _ 10' BRL r LOT 28 _ CONC. : ' 32.3' o STEPS ao o J 16.4' `° O I— .. 3 0 10.1' in O Q 0 I� (.-^1 I 1.6' a 3CD 0 O ` a0 '' = LL N Q N N � - W ET) U Q Q _ o cI t� W I-- (9.5)P CONC. it 3 Z< m Ur LOT 29 (9.4)E 5.5' 2 STORY FRAME 1.6' 9.t RESIDENCE #1721 if) ..-,.r Z EXIST. RESIDENCE W J F.F.EL.=(12.15) v Z < O F.F.EL.=(12.3)P o m _J Nt m o t , F_ `• nt in – L Q 1.6 • 0 1n Z P•'') 1.;2. 10.0' <L 'j al N , 0 14.0' m m m 5.6' 21.6' w( N 7.8' o 0, < <I k t IcJ 14.7' od l�J PORCHL j • < ' `L 1<1$' BRL' ' , . • CONCRETE DRIVEWAY <iN, L STEPS 7.5' J.E.A.–E (8.9)P c•}C'' (8.7)6 spy ��G RECLAIMED WATER VALVE l� \ S32'41-RWV '16"E 50.00'(8.7)E �`�°Q IBM- WV i 0 WATER WATER VALVE ✓<+y7Qp ' ' 'Arm METER P.C.P. (PI) FIRE HYDRANT— < EL.=(9.05) (8.56)BC • �' ` 4 , (8.72)BC CA=90'00'00" ATLANTIC BEACH DRIVE R=25.00' (50' RIGHT OF WAY) L=39.27' SEPTEMBER 16, 2020; FINAL SURVEY(2016-316-6) AAE CB=N77.41'16"W JUNE 26, 2020; STAKE NORTH PROPSERTY LINE(2016-361-5) WJM 1� NOVEMBER 10, 2019; FOUNDATION SURVEY(2016-361-4) AAE 1422-79 CH=35.36' NOVEMBER 1, 2019; LOT& HOUSE STAKEOUT(2016-361-3) DEW 1422-9 JULY 24, 2019; TOPOGRAPHIC SURVEY/SITE PLAN (2016-361-2) NUM 1408-61 UNLESS IT BEARS THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER, THIS DRAWING, SKETCH, PLAT OR MAP IS FOR INFORMATIONAL PURPOSES ONLY, AND IS NOT VALID. NOTES LEGEND DA TE 9-3-16 I. Bearings ore based on the centerline PCP's of the Atlantic Beach Drive (S147725"E) SCALE 1"=20 2. This is a BOUNDARY SURVEY. Q DENOTES CONCRETE MONUMENT 3. Elevations shown thus (15.0) refer to North American Vertical Datum x—x DENOTES FENCE JOB No. 2016-361 of 1988, (NA VD 88). 0 DENOTES 1/2'IRON PIPE SET F.B. – 4. By Graphic plotting only, the property shown hereon lies within Zone "X' KITH CAP, R. MILLER&ASSOC. - as shown on the Federal Emergency Management Agency(F.E.M.A.), National Flood Insurance 0 DENOTES IRON PIPE FOUND page Program, Flood Insurance Rote Map (FIRM.) Community-Panel Number 12031C-0406) w/CAP, R. MILLER&ASSOC. Comp. File ABCC_Lot_28.dwq Map Revised date .- 11/2/2018 Drown by WJM 5 Unless otherwise noted, any portion of the parcel that may be deemed as Wetlands by State or Governmental Agencies, hos not been determined and any liability resulting RICHARD A. MILLER & ASSOCIATES therefrom is not the responsibility of the undersigned. 6. There may be Restrictions or Easements of Record evidenced by title examination that PROFESSIONAL LAND SURVEYORS have not been shown hereon. 11437 CENTRAL PARKWAY, SJITF_ 107 Fox (904) 721-5758 ABBREVIATIONS THAT MAY BE USED IN THIS SURVEY JACKSONVILLE, FLORIDA 32224 Tele. (904) 721-1226 ABBREVIATION DEFINITION ABBREVIATION DEFINITION P.C.P. Permanent Control Point L.B. Licensed Business nes IS to CERTIFY THAT MIs s,enwY ISA TRUE REPRESENTATION OF AN ACTUAL P.R.M. Permanent Reference Monument R.L.S. Registered Land Surveyor FIELD SURIfY,MADE UNDER MY SUPERM9OB AND N ACCORDANCE IKON THE P.O.B. Point of Beginning J.E.A. Jacksonville Electric Authority miNimuM TFCHW/CAL STANDARDS AS OUTLINED AND SET FORTH Br THE FLORIDA P.C. Point of Curvature EQUIP Equipment BOARD OF PROFESSIONAL LAND.'.1/Rwices AND MAPPERS,IN CHAPTER 5✓-17. P.T Point of Tangency A/C Air Conditioner (formerly CHAPTER 61017-6A FLORIDA ADMAWSTRAToir PURSUANT TO P.R.C. Point of Reverse Curvature C.A.TV Cable Television SECtxW 477.027,FLORIDA STATUTES P.I. Point of Intersection OHL Overhead Lines R/W Right (F.M.) FieldMeasured O.R.V Officialal Records Volume R= Radius equals D.B. Deed Book L= Arc Lenth equals Pg. page Ch.= Chord Bearing & Distance equals BY: (A.kr B.R.L. Building Restriction Line LI= Delta or Central Angle equals WILLIAM J. MELROS 480F FLORIDA, REGISTERED Esmt Easement 1.P. Iron Pipe LAND SURVE i' / ICATE No. 5843 Conc. Concrete