Loading...
1021 Atlantic Blvd Unit 19 ROOF21-0008 NonshingleOWNER:ADDRESS:CITY:STATE:ZIP: EQUITY ONE ATLANTIC VILLAGE INC 1600 NE MIAMI GARDENS DR NORTH MIAMI BEACH FL 33179 COMPANY:ADDRESS:CITY:STATE:ZIP: ROOF CONTROL SERVICES 11748 OSPREY POINT BLVD CLERMONT FL 34711 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 177602 0040 SECTION LAND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1021 ATLANTIC BLVD 953- 975 ROOF NON SHINGLE MODIFIED BITUMEN -Unit 19 SOLA SALON $86451.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. b. All roofing projects require an In-Progress Inspection. c. Sheathing installation and replacement guidelines per APA. d. Underlayment must conform to FBC-R Table 905.1.1 e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 2/23/2021 PERMIT NUMBER ROOF21-0008 ISSUED: 2/23/2021 EXPIRES: 8/22/2021 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $428.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $214.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $9.63 STATE DCA SURCHARGE 455-0000-208-0600 0 $6.42 TOTAL: $658.05 2 of 2Issued Date: 2/23/2021 PERMIT NUMBER ROOF21-0008 ISSUED: 2/23/2021 EXPIRES: 8/22/2021 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $658.05 ROOF21-0008 Address: 1021 ATLANTIC BLVD 953-975 APN: 177602 0040 $658.05 BUILDING $428.00 BUILDING PERMIT 455-0000-322-1000 0 $428.00 BUILDING PLAN REVIEW $214.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $214.00 STATE SURCHARGES $16.05 STATE DBPR SURCHARGE 455-0000-208-0700 0 $9.63 STATE DCA SURCHARGE 455-0000-208-0600 0 $6.42 TOTAL FEES PAID BY RECEIPT: R14987 $658.05 Printed: Tuesday, February 23, 2021 2:30 PM Date Paid: Tuesday, February 23, 2021 Paid By: ROOF CONTROL SERVICES Pay Method: CREDIT CARD 426475771 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R14987 ROOF21-0008 General Scope for Atlantic Village, Units 1-10: Existing roof is a gravel-surfaced BUR over 1.50" perlite. Scope: a) Vacuum the loose gravel from the roof. b) Install/ mechanically attach 1" ISO board (6-fasteners per board). c) Install Soprafix System: i) Mechanically Attached a Base Ply (Soprema 612) in seam at 12" oc with 4" overlap, then torch or heat weld the seam closed (see attached PDF. Increased fastener enhancements at perimeter and corners -see attached base faster enhancement diagram). ii) Soprema, the roof system manufacturer to perform an in-progress inspection of the base layer. iii) Torch apply a cap sheet (Sopralene Flam 180 FR GR). iv) Soprema, the roof system manufacturer, to perform a final inspection following cap- sheet installation, and completion of all penetration flashings. -Terminate front and side-wall flashings with both t-bar and counterflashing combo at 12" oc; Flashing of existing penetrations: Approximately four-(4) roof curbs (approximately 2'x4' in size). Approximately eight-(8) pipes and/or pitch-pans. Submit Surcharge Stats & racts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User £'.!:Qduct_tl~Menu > Product or Application Searcl·, > P.&Q)1_£at1on Li§!> Application Detail FL# Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL3915-R27 Revision 2017 Approved Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281 (800) 356-3521 dperry@soprema.us Darren Perry dperry@soprema.us Darren Perry 3010 Pinecrest Drive Greenville, NC 27858 (252) 414-3020 dperry@soprema.us Roofing Modified Bitumen Roof System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report -Hardcopy Received Robert Nieminen PE-59166 UL LLC 04/02/2022 John W. Knezevich, PE Validation Checklist -Hardcopy Received fL391;2._8,27 COI 2019 01 COl NIEMif\lEN.pdf Standard ASTM D6162 ASTM D6163 ASTM D6164 ASTM D6298 FM 4470 FM 4474 Year 2008 2008 2011 2005 2012 2011 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL# Model, Number or Name Method 1 Option D 02/14/2019 02/18/2019 02/22/2019 04/16/2019 Description 3915.1 Soprema Modified Bitumen Roof Modified Bitumen Roof Systems Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL39l5 R27 II 2019 02 FINAL Al ER Approved for use outside HVHZ: Yes B.27.pdf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-650 Created by Independent Third Party: Yes Other: 1.) The design pressure noted in this application Evaluation Reports SOP8.EMA FL39l5- pertains to a particular assembly. Refer to ER Appendix for all FL3915 R27 AE 2019 02 FINAL ER SOPREMA FL39l5- assemblies and max. design pressures. 2.) Refer to ER R27.pdf Section 5 for Limits of Use. Created by Independent Third Party: Yes DD Contact Us:: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. : : Privacy Statement : : Accessibility Statement : : Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: [ill~ Credit Card Safe SOPRAFX 1\/1ECHAI\JICAUY FASTE~JEC TV\/0-PLY SBS-1\/iOCIFIED 81TUfv1E1\J MEMBRA:\JE SYSTEM II 13tlii!hiii~!;I ®#R11436 <e> APPROVED I l SOPRAFIX BASE PLY Soprafix Base 611 (New)) Soprafix Base 612 (Soprafix S) 4 ; Soprafix Base 613 (Soprafix F) 4 !. S.°.?..rafix Base_614 (S?.prafix X) 4 HEAT APPLIED CAP PLY AREA (SQ)1 MAXIMUM THICKNESS TOP SIDE LAP AVAILABLE (MILS) 2 SURFACE TREATMENT RATING 3 1.5 98 Poly film Heat weld FM 1-285 1.0 118 Poly film Heatweld FM 1-285 1.0 118 Poly film Heat weld FM 1-150 1.0 157 Poly film Heat weld FM 1-345 ........ ; .... -------+----------; AREA THICKNESS TOP BOTTOM FIRE (SQ) 1 (MILS) 2 SURFACE SURFACE CLASSIFICATION 3 Soprastar Flam 1.0 138 Bright white film Poly film 2:12 Class A Elastophene Flam LS FR GR 1.0 130 Granules Poly film 1/2:12 Class A 1-------------~----+-----+-------------+--------, f-S_o_p_ra_le_ne_F_l_am_18_0_F_R_G_R _______ 1_.0 ____ 1 1 5 5 _7 7 __ ....... 1 1 ..... _G_r_an_u_le_s _ -~-P_o_ly_fi_lm_---+--·-1 :_12_C_l_as_s_A I Sopralene Flam 180 FR+ GR 1.0 Granules Poly film 2:12 Class A I Sopralene Flam 180 Ultra FR GR 1.0 ... ~.~! ......... J ... _G_r_a_nu_le_s_~ __ Po_ly_fi_1lm_~ 3:12 Class A SOPRAFIX BASE PLY AREA (SQ)1 Soprafix Base 622 (Soprafix) 4 1.0 102 Soprafix Base 641 (Soprafix E) 4 1.0 110 ADHESIVE APPLIED CAP PLY AREA THICKNESS (SQ)1 (MILS)2 Soprastar Sanded 1.0 138 Elastophene LS FR GR 1.0 136 Sopralene 180 FR GR 1.0 157 Sopralene 180 FR+ GR 1.0 157 .......... Sopralene 180 Ultra FR GR 1.0 157 I SOPRAFIX BASE PLY AREA THICKNESS I (SQ)1 (MILS)2 Soprafix Base 641 (Soprafix E) 4 1.0 110 SELF-ADHERED CAP PLY AREA THICKNESS (SQ)1 (MILS) 2 ··········------.. .--.,.-.. Elastophene Stick HR FR GR 1.0 138 LIL r'.ili:;mi .. Da(!e J11c FBC fr,r E:v~ilslilE; r:1tinqs Sr-•(-produc~ \"·r(:'Vl(JU$ tcdE, n:::.n1f .) .. pl~, p,{,..E:ntl·!E!~~es TOP SURFACE Sanded Sanded TOP SURFACE Bright white film Granules Granules Granules Granules TOP SURFACE Sanded TOP SURFACE Granules SIDE LAP TREATMENT Heat weld Self-adhered BOTTOM SURFACE Sanded Sanded Sanded Sanded Sanded SIDE LAP TREATMENT Self-adhered BOTTOM SURFACE Release film lc.ipwrdlh FM 1-285 FM 1-180 FIRE CLASSIFICATION 3 2:12 Class A 1/2:12 Class A 1 :12 Class A 2:12 Class A 3:12 Class A MAXIMUM AVAILABLE RATING 3 FM 1-180 FIRE CLASSIFICATION 3 3/4:12 Class A SOPREMA INC. 310 Quadral Drive Wadsworth, Ohio 44256 800.356.3521 www.soprema.us Fasten the Soprafix SBS base ply side laps in accordance with industry approvals and SOP REMA instructions.* *SOPREMA's patented Tri-Fixx fastening system is ideal for lightweight insulating concrete applications providing superior wind ratings. Seal the full width of the Soprafix SBS base ply side lap. Install the SBS base flashing ply. Install the SBS capply. SBS Cap ply options indude heat welding, cold adhesive and self-adhered applications. Install SBS cap flashing. JdB COPY DESCR IPT I ON & f=EA TURES ........................................... _ .... _ ................................................................................... ·---...... ......... ........ ....................... ........... .... ............... . .. _ .. _ ........................................... . SOPRALENE Flam 180 FR GR (fire retardant , granulated) is an SBS-modified bitumen cap ply for use in approved multi -ply membrane and flashing assemblies . SOPRALENE Flam 180 FR GR is composed of a proprietary formulation of elastomeric styrene-butadiene- styrene (SBS) polymer modified bitumen and is reinforced with a tough , dimensionally stable non-woven polyester mat. The topside is surfaced with ceramic coated granules and underside is surfaced with polyolefin burn-off film to optimize heat welding. SOPRALENE Flam 180 FR GR includes the standard white granules. Contact SOPREMA ® Customer Service or your sales representative for other granule color options and special order requirements. STORAGE & HANDLING Store rolls on end and maintain in an upright position to prevent damage. Store rolls in a clean dry location and cover as necessary to protect rolls from environmental damage such as extreme cold, heat , or moisture. Monitor varying environmental conditions during storage, handling and application of SOPRALENE Flam 180 FR GR. APPLICATIOf\J .................................. ___ ..... .., ............... -.................................................... ___ _ _ __ ............................................................................ -...... . Prior to installation, unroll SOPRALENE Flam 180 FR GR onto the roof surface and allow to relax. Position SOPRALENE Flam 180 FR GR in desired position and back roll the product. SOPRALENE Flam 180 FR GR is then heat welded to approved substrates. Refer to the SOPREMA SBS Roofing Installation Guide for additional application guidelines. SOPRALENE Flam 180 FR GR 0 .27 0.24 Standard white granules (WH) initial 3 year SOPRALENE Flam 180 FR GR 0.66 0.62* Highly reflective white granules (SG) initial 3 year HEAT-WELDED SOPRALENE Flam 180 FR GR 0.10 N/A .• Smog reducing granules (EC03) initial ** *CRRC Rapid Ratings. Refer to Cool Roof Ratings Council (CRRC). **Calculated using internal testing • Coverage rate as reported assumes installation using side and en d lap recommendations . www.soprema.us 310 Quadral Drive , Wadsworth, Ohio 44281 Toll Free: (800) 356-3521 I Tel: (330) 334-0066 0.87 0.90 27 234 initial 3 year initial 3 year 0.91 0.91 * 81 75 initial 3 year initial 3 year 0.89 N/A 6 N/A initial ** initial ** Reinforcement Non-woven polyester Elastomeric bitumen Proprietaty blend of bitumen and SBS polymers Top surfacing Ceramic coated granules Back surfacing Polyolefin film Selvage surface Polyolefin film Selvage width, in (mm) 3 in (76 mm) End lap, in (mm) 6 in (152 mm) Thickness, mils (mm) 160 (4.0) ASTM D5147 Thickness @ selvage, mils (mm) 118 (3.0) ASTM 05147 Net mass per unit area, lb/100ft2 (g/m2) 110 (5371) ASTM D5147 Bottom coating thickness, mils {mm) ~ 40 (1.0) ASTM D5147 Peak load @ 0°F (-18°C), lbf/in (kN/m) 115(20.1) 90 (15.8) ASTrl/1 D5147 Elongation at peak load @ 0°F (-i 8°C), % 35 40 ASTM 05147 Peak load@ 73.4°F (23°C), lbf/in (kN/m) 85 (14.9) 65 (11 .4) ASTM D5147 Elongation at peak load@ 73.4°F (23°C), % 55 60 ASTM D5147 Ultimate elongation @ 73.4 °F (23°C), % 65 80 ASTM D5147 Tear strength@ 73.4°F (23°C), lbf (N) 125 (556) 85 (378) ASTM D5147 Low temperature flexibility, °F (0 C) -15 (-26) -15(-26) ASTM D5147 Dimensional stability, % <0.5 <0.5 ASTM D5147 Compound stability, °F (0 C) 240 (116) 240 (116) ASTM D5147 Granule embedment, g < 1.5 avg; 2.0 max SG ASTM D5147 Cyclic fatigue, condition 5 Pass ASHA D5849 * Data is represented by average values, unless noted otherwise. PDS10003 -REV. 023419 JOB COPY DESCRIPTION & FEATURES SOPRAFIX Base 612 is an SBS-modified bitumen base ply for use in approved multi-ply membrane and flashing assemblies and is designed specifically fo r mechanical attac hment to approved substrates . SOPRAFIX Base 612 is composed of a proprietary fo r mulat ion of elastome ric sty rene-butadiene-styrene (SBS) polymer modified b itumen and is reinforced with a tough , dimensionally stable non-woven polyester mat engineered for mechanical attachment. The tops ide and underside are surfaced with polyolefin burn-off film to optimize heat welding . STOFlAGE & HANDLING Store rolls on end and maintain in an upright position to p revent damage . Store rolls in a clean dry location and cover as necessary to protect rolls from environmental damage such as extreme cold, heat, or moisture . Monitor varying environmental conditions du ring storage , handling and application of SOPRAFIX Base 6 12 . APPUCATION Prior to installation, unroll SOPRAFIX Base 612 onto the roof surface and allow to relax. Place SOPRAFIX Base 612 in desired position . SOPRAFIX Base 612 is mechanically fastened through the 4 inch or 5 inch side laps using the 2 inch or 2 .4 inch plates respec t ively following the details for the required uplift pressure. Subsequent approved inter-ply or cap ply membranes are applied to SOPRAFIX Base 612 via heat welding . Refer to the SOPREMA® SBS Roofing Manual for additional application guidelines . MECHANICALLY FASTENED • Cove rage rat e as reported assumes install ation using side and end lap recommendation s . Cov erage reported refle cts 4 and 5 inch sid e laps respectively. www.soprema.us 310 Quadral Drive, Wadsworth, Ohio 44281 To ll Free: (800) 356-3521 I Te l: (330) 334-0066 j Reinforcement Non-woven polyester Elastomeric bitumen Proprietary blend of bitumen and SBS polymers Top surfacing Polyolefin film Back surfacing Polyolefin film Selvage width, in (mm) 4 (102) and 5 (127) End lap, in (mm) 6 (152) Thickness, mils (mm) 118 (3.0) ASTM D5147 Net mass per unit area, lb/100ft2 (g/m2) 76 (371i) ASTM D5147 Peak load @ 0°F (-18°C), lbf/in (kN/m) 115 (20.1) 90 (15.8) ASTM D5147 Elongation at peak load @ 0°F (-18°C), % 35 40 ASTM D5147 Peak load@ 73.4"F (23°C), lbf/in (kN/m) 85 (14.9) 65 (i 1.4) ASTM D5i47 Elongation at peak load@ 73.4°F (23°C), % 55 60 ASTM D5"147 Ultimate elongation@ 73.4°F (23°C), % 65 80 ASTM D5147 Tear strength @ 73.4°F (23°C), lbf (N) 125 (556) 85 (378) ASTM D5147 Low temperature flexibility, °F (0 C) -15(-26) -15(-26) ASTM D5147 Dimensional stability, % <0.5 < 0.5 ASTM D5147 Compound stability, °F ("C) 240 {116) 240 (116) ASTM D5147 * Data is represented by average values, unless noted otherwise. FLORIDA BUILDING CODE PDS10009 -REV. 020915 SAFETY DAT A SHEET SBS MODIFIED BITUMEN WATERPROOFING MEMBRANE Offerte en fram;ais GHS PROTECTIVE CLOTHING TRANSPORT OF DANGEROUS GOODS Not regulated Not regulated SECTION I: IDENTIFICATION Trade names: Sopralene Stick, Sopralene Flam Stick, Sopralene 180 PS 2.2, Sopralene 180 Sanded 2.2, Colphene 180 Sanded, Colphene Stick, Soprafix Base 621, Soprafix Base 610, Sopiafix Base 611, Sopiale11e 180 Sanded, Sopralene 180 PS 3.0, Sopralene Flam 180, Sopralene 180 SP 3.0, Sopralene SP 3.5, Colphenc Flam 180, Soprafix Base 613, Soprafix Base 622, Soprafix Base 641, Soprafix Base 612, Colvent 180 SA, Colvent Flam 180 SA, Colvent 180 TG, Colvent Flam 180 TG, Sopralene Flam Antirock, Soprafix Base 614, Sopralene 250 Sanded, Sopralene Flam 250, Sopralene 180 FR GR, Sopralene Flam 180 FR GR, Sopralene Flam 180 Ultra FR GR, Sopralene 180, Colvent 180 FR GR, Sopralene Flam 250 FR+GR, Sopralene 250 FR GR, Sopralene Flam 250 FR GR, Sopralene Ultra FR GR, Sopralene Flam Ultra FR GR, Sopralene 250 FR+ GR, Soprastar Flam, Soprastar Stick, Soprastar Sanded, Sopralast TV Alu, Sopralast TV Alu Sanded, Elastophene HS Sanded, Elastophene Flam HS, Elastophene Flam HS FR, Elastophene HS FR Sanded, Elastophene HS FR GR (WHT), Elastophene Flam HS FR GR (WHT), M-SBase, M-Xpress, Sopra IV, Sopra VI, Sopraflash, Sopraglass, Sopraseal, Soprawalk, Sopremium, Starter Stick GR, Stickson. Membranes are used for all types of roofing needs, air barrier and waterproofing protection. Manufacturers SOPREMA Canada and distributors: 1675 Haggerty Street Drummondville (Quebec) J2C 5P7 CANADA Tel.: 819 478-8163 In case of emergency: SOPREMA Inc. 44955 Yale Road West Chilliwack (B.-C.) V2R 4H3 CANADA Tel.: 604 793-7100 SOPREMA USA 310 Quadral Drive Wadsworth (Ohio) 44281 UNITED ST ATES Tel.: 1 800 356-3521 SOPREMA Gulfport 12251 Seaway Road Gulfport (Mississippi) 39503 UNITED ST ATES Tel.: 228 701-1900 SOPREMA (8:00am to 5:00pm): 1 800 567-1492 CANUTEC (Canada) (24h.): 613 996-6666 CHEMTREC (USA) (24h.): I 800 424-9300 SECTION II: HAZARD(S) IDENTIFICATION Bitumen membrane. Asphalt odor. Under normal use, this product is not expected to create any health or environmental hazard. Inhalation of dust or of asphalt fumes can cause a slight respiratory irritation and/or congestion. SECTION III: COMPOSITION AND INFORMATION ON HAZARDOUS INGREDIENTS NAME CAS# % WEIGHT EXPOSURE LIMIT (ACGIH) TLV-TWA TLV-STEL BITUMINOUS BLEND Bitumen 8052-42-4 30-70 0.5 mglm3 Not established Asphalt fumes Oxidized bitumen 1 64742-93-4 0-20 0.5 mglm 3 Not established Asphalt fumes Self-adhesive membranes contain: 64742-52-5 0-30 Not established Not established Hh?:hly hydrotreated naphthenic oi1 1 Calcium Carbonate1 471-34-1 0-60 10 mglm3 Not established Styrene butadiene copolymer1 9003-55-8 0-15 10 mglm3 Not established FR products contain: Calcium borate 1 1318-33-8 7-15 10 mglm3 Not established FR Plus products contain: Fire retardant1 Proprietary 1-5 2 mglm 3 Not established REINFORCEMENT Some products may contain fibre 2lass, polyester or a mix of 2lass 2rid and polyester. Polyester mat 1 NIA 1-7 Not established Not established l<'ibre glass mat1 NIA 1-7 Not established Not established Contains: Fibre glass filament 1 65997-17-3 0,5-7 lf/cc Not established SBS Modified Bitumen Waterproofing Membrane Revision date: April 30, 2015 Page 1 of 4 UNDERFACEANDSURFACE Some membranes are protected by sand, talc, mineral granule, silicone paper, polyethylene or polypropylene film, aluminium, copper or stainless steel foil. Silicone paper NIA 6-20 Nol eslablished Not established Polvoroovlene film NIA 2-10 Not established Not established Polvethylene film 9002-88-4 2-10 Not established Not established Aluminium, coooer or stainless steel foil NIA 4-15 Not established Not established Sand NIA 7-13 0.1 mg/m3 Not established Contains: Crystalline silica 2 14808-60-7 7-13 0.025 mg/m3 Not established Talc 14807-96-6 7-13 Not established Not established Coloured granules NIA 15-40 Not established Not established Contains: Crystalline silica 2 14808-60-7 < 12 0.025 mg/m3 Not established 1. The exposure to the substance above the limits of exposure is not likely to occur considering its form (incorporated in the mixture) and/or the provided use. The limit of exposure is given for reference only. 2. A proportion of crystalline silica can be present in the sand sprinkled on the top of some membranes. The crystalline silica contained in the sand is not likely to be found in the ambient air in concentration above the limit of exposure since the sand adheres to the surface of the membrane. SECTION UI: POTENTIAL HEALTH EFFECTS Effects of short term (acute) exposure SKIN CONT ACT The product can cause a mechanical irritation of the skin because of its rough surface. If the membrane is torch-applied, asphalt fumes can cause skin irritation. The asphalt fumes can cause an irritation of the skin. The contact with this product at high temperature can cause thennal burns. EYE CONTACT The product is not likely to cause effects to the eyes. If the membrane is torch-applied, asphalt fumes can be emitted of the product and cause irritations, redness and conjunctivitis to the eyes. The contact with this product at high temperature can cause thermal burns. INHALATION The product is not likely to cause effects on the respiratory system. If the membrane is torch-applied, asphalt fumes can be emitted of the product and cause irritations to the nose, the throat and the respiratory tracts, tiredness, headaches, dizziness, nauseas and insomnia. INGESTION Exposure is not likely to occur by this route of entry under nonnal use of the product. Effects of long term (chronic) exposure SKIN CONT ACT The repeated or prolonged contact can cause irritation. If the membrane is torch-applied, asphalt fumes can be emitted. The long-term exposure to the asphalt fumes can cause changes of the pigmentation of the skin which can be worsened by the exposure to the sun. (1) INHALATION If the membrane is torch-applied, asphalt fumes can be inhaled. No data on chronic effects of the exposure to asphalt fumes on the lungs. CARCINOGENICITY Due to the product fonn, exposure to hazardous dusts or fumes is not expected to occur. Information on carcinogenicity is given for reference only. This product is not classifiable as a carcinogen. Bitumen: According to the International Agency for Research on Cancer (IARC): not classifiable as to its carcinogenicity to humans. Epidemiological studies of roofers have generally demonstrated an excess of lung cancer in these workers. However, it is unclear to what extent these cancers may be attributable to asphalt exposures during roofing operations, since in the past, roofers have been exposed to coal tar and asbestos, which are known human lung carcinogens. Trace amounts ofpolynuclear aromatic hydrocarbons (PAHs) may be present in some asphalts and can be released upon excessive heating. Some of these P AHs have been identified as having the potential to induce carcinogenic and reproductive health effects. (2) Oxidized bitumen: In its 2013 monograph (Volume 103), the International Agency for Research on Cancer (IARC) conducted a review of the potential carcinogenicity of bitumen (the European term for asphalt). One of its conclusions was "occupational exposures to oxidized bitumens and their emissions during roofing" are classified in IARC Group 2A, "probably carcinogenic to humans." However, due to the product form, exposure to such component is unlikely under normal conditions ofuse. (2) Crystalline Silica: Breathable crystalline silica from sand is not expected to be released, sand is adhered to product. According to IARC, crystalline silica is carcinogenic for human by inhalation. (3) Fibreglass Filament: Fibreglass is not expected to be released. In 2001, IARC classified fibreglass as Group 3 "not classifiable as to its carcinogenicity to humans". The American Conference of Governmental Industrial Hygienists (ACGIH) and the National Toxicology Program (NTP) classify the substance in Group 2B (possibly carcinogenic to humans) based on studies in which animals were injected with large quantities of fibreglass. The other ingredients were not found to be carcinogenic or no information is available on that matter. TERATOGENICITY, EMBRIOTOXICITY, FETOTOXICITY No infonnation available. REPRODUCTIVE TOXICITY No information available. MUTAGEN! CITY No information available. TOXICOLOGICALLY SYNERGISTIC MATERIALS No information available. POTENTIAL ACCUMULATION No information available. SECTION IV: FIRST-AID MEASURES SKIN CONT ACT If there is presence of dust on the skin, wash gently with water and soap. In the event of contact with the product melted, do not try to remove the product of the affected area and rinse the area affected in cold water. Obtain immediate medical attention. At the end of each working day, clean all the parts of the body which came into contact with asphalt fumes. Clean the clothing contaminated by the asphalt fumes. EYE CONTACT SBS Modified Bitumen Waterproofing Membrane Revision date: April 30, 2015 Page2 of4 Flush eyes with water for at least 15 minutes while holding eyeiids open. Do not attempt to remove material from affected area without medical assistance. Obtain immediate medical attention. INHALATION Remove victim from contaminated place and restore breathing, if required. INGESTION The ingestion of this product is not very likely to occur. SECTION V: FIRE-FIGHTING MEASURES FLAMMABILITY: Not applicable EXPLOSION DAT A: Not applicable FLASH POINT: Not applicable AUTO-IGNITION TEMPERATURE: Not applicable FLAMMABILITY LIMITS IN AIR:(% in volume) Not applicable FIRE AND EXPLOSION HAZARDS Asphalt fumes are flammable. Torch, used to weld waterproofing membranes, can produce temperatures beyond 1100°C (2000°F). A void all contact with materials sensitive to these temperatures, as lead or plastic materials. Never work in an enclosed area where gas can accumulate. Shield air conditioning units and other protrusions on the roof with perlite panels or similar material when using the torch around them. Never use torch (es): -When substrate(s) have been recently covered by solvent-based products (wait until it is dry). -Near any combustible materials. -Close to containers containing flammable liquids or materials (keep open flame at least 3 m [1 O'] away). -Directly on combustible substrate or insulation. Voids, holes or gaps in substrate or located nearby the welding zone can be protected against flame penetration. Particular precautions must be taken to keep combustible or heat sensitive insulation away from the torch flame. If wood fibre panels must be installed, use fireproof panels. A void presence of combustible materials near open flame. At all times and especially when leaving job site, make sure that there is no smouldering or concealed fire. In that case, strictly follow the safety measures. Job planning must allow for employee presence on the roof at least one hour after torch application. At the end of every day, use a heat detector gun to discover any unusually hot surface. Always have one ABC fire extinguisher on hand, filled and in perfect working order near each torch. COMBUSTION PRODUCTS Burning of this material will produce thick black smoke. Initating and/or toxic gases including Hydrogen Sulphide and Sulphur Dioxide, traces of metallic fumes may be generated by thermal decomposition or combustion. FIRE FIGHTING INSTRUCTIONS Evacuate the area. Wear self-contained breathing apparatus and appropriate protective clothing in accordance with standards. Approach fire from upwind and fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Always stay away from the containers at the time of the fire considering the high risk of explosion. Move the rolls of membrane from fire area if it can be done without risk. Cool the rolls of membrane with flooding quantities of water until well after fire is out. EXTINGUISHING MEDIA: Foam, CO 2, sand, chemical powder. SECTION VI: ACCIDENTAL RELEASE 1\-IEASU RELEASE OR SPILL If hot material is spilled, allow enough time to cool completely and remove to a container for disposal. Wear appropriate breathing apparatus (if applicable) and protective clothing. Notify appropriate environmental agencies. Wash spill area with soap and water. Dispose of this material according to local environmental regulations. SECTION VII: HANDLING AND STORAGE HANDLING SOPREMA's produt:ts must be applied by qualified applicators who have received an adequate training, for the prevention and the protection (in particular for the use of the extinguishers) against accidents caused by use of combustible or flammable materials, of liquefied propane gas, open flame, and their material of installation. The present recommendations must be imperatively related to the knowledge of the employees before the application of the products to the building site. Check the construction and the composition of the systems of roof and the walls before welding. Ensure of the cleanliness of the places (debris). Precautions of the use of the torch: Use only proper torching equipment in perfect working order, C.S.A. certified. Never modify torching equipment. Use only proper hoses suited for propane gas of less than 15 m (50'). Verify and tighten all the connections before the use of the equipment. Do not light the torch if a propane odor is present. Never seek a leak with a flame. Use a torch whose gas output is adjustable with stopping device. Follow the specifications, notices and documentations of the manufacturers. STORAGE Flashings must be stored in such a way to prevent any creasing, twisting, scratches and other damages of the roof. The materials must be protected adequately and stored permanently away from flames or welding sparks, protected from bad weather and any harmful substances. Store self-adhesive membranes away from the sun. SECTION VIU: EXPOSURE CONTROLS / PERSONAL PROTECTION HANDS: Wear resistant gloves. RESP IRA TORY: If the TL V for dust is exceeded, if use is performed in a poorly ventilated confined area, use an approved respirator in accordance with standards. EYES: Wear safety goggles in accordance with standards. BODY: Wear adequate protective clothes. Do not wear synthetic fabric. Remove clothing contaminated with solvents. OTHERS: Eye bath and safety shower. SECTION IX: PHYSICAL Al\1D CHEMICAL PROPERTIES PHYSICAL STATE: Solid ODOR AND APPEARANCE: Black membrane with asphalt odor ODOR THRESHOLD: Not available VAPOR PRESSURE (20°C): Not applicable VAPOR DENSITY (air= 1 ): Not applicable EVAPORATION RATE (Butyl acetate= 1): Not applicable BOILING POINT (760 mm Hg): Not applicable FREEZING POINT: Not applicable SPECIFIC GRAVITY (1-JiO = 1): Variable SOLUBILITY IN WATER (20°C): None VOLATILE ORGANIC COMPOUND CONTENT (V.O.C): Not measurable (0 g/L) VISCOSITY: Not applicable SECTION X: STABILITY AND REACTIVITY ST ABILITY: This material is stable. CONDITIONS OF REACTIVITY: Avoid excessive heat. INCOMPATIBILITY: Acid and strong basis and organic solvents and greasy substances. HAZARDOUS DECOMPOSITION PRODUCTS: None identified. HAZARDOUS POLYMERISATION: None. SBS Modified Bitumen Waterproofing Membrane Revision date: April 30, 2015 Page3 o/4 SECTION XI: TOXICOLOGICAL INFORMATION Effects of Short-Term (Acute) Exposure No information available. Effects of Long-Term (Chronic) Exposure CARCINOGENICITY Bitumen: Data from experimental studies in animals and cultured mammalian cells indicate that laboratory-generated roofing asphalt fume condensates are genotoxic and cause skin tumours. (2) Crystalline Silica: Several studies have shown an increased incidence of lung tumours in rats exposed to quartz by inhalation for up to 2 years. IARC has determined that there is sufficient evidence that quartz is carcinogenic to experimental animals. (3) The other ingredients were not found to be carcinogenic or no information is available on that matter. REPRODUCTIVE EFFECTS No information available. TERATOGENICITY, EMBRYOTOXICITY, FETOTOXICITY No information available. MUTAGENICITY Crystalline Silica: None according to the available information. No information available about the other ingredients. SYNERGISTIC MATERIALS Tobacco smoke increases the effects of silica dust on respiratory system. Simultaneous exposure to known carcinogens as benzo (a), pyrene, can increase the carcinogenicity of crystalline silica. SECTION XII: ECOLOGICAL INFORMATION ENVIRONMENT AL EFFECTS No data. BIODEGRADABILITY This product is not biodegradable. No possible bioaccumulation and unlikely bioconcentration in the food chain. SECTION XIII: DISPOSAL CONSIDERATIONS WASTE DISPOSAL This product is not hazardous waste. Consult local, provincial, territory or state authorities to know disposal methods. This material is not listed by the EPA as hazardous waste according to the Resource Conservation and Recovery Act (RCRA) of the United States. No Environmental Protection Agency (EPA) waste numbers are applicable for this product. SECTION XIV: TRANSPORT INFORMATION This product is not regulated by Department of Transportation (DOT) and Transportation Dangerous Goods (TDG). SECTION XV: REGULATORY INFORMATION DSL: TSCA: Prop. 65: All constituents of this product are included in the Domestic Substances List (Canada). All constituents of this product are listed on the Toxic Substances Control Act Inventory (TSCA -United States). This product contains chemicals known to the State of California to cause cancer or reproductive toxicity. SECTION XVI: OTHER INFORMATION GLOSSARY ACGIH: ANSI: ASTM: CAS: CFR: CSA: DOT: DSL: EPA: GHS IARC: LDsofLCso: NFPA: NIOSH: NTP: OSHA: RCRA: TDG: TLV-TWA: TSCA: References: American Conference of Governmental Industrial Hygienists (United States) American National Standards Institute (United States) American Society for Testing and Materials (United States) Chemical Abstract Services Code of Federal Regulations (United States) Canadian Standardization Association Department of Transportation (United States) Domestic Substances List (Canada) Environmental Protection Agency (United States) Globally Harmonized System International Agency for Research on Cancer Less high lethal dose and lethal concentration published National Fire Protection Association (United States) National Institute for Occupational Safety and Health (United States) National Toxicology Program (United States) Occupatfonal Safety & Health Administration (United States) Resource Conservation and Recovery Act (United States) Transportation of Dangerous Goods (Canada) Threshold Limit Value -Time-Weighted Average Toxic Substances Control Act (United States) (1) Safety Data Sheet from the supplier (2) WHO (2013) Bitumens and bitumen emissions, and some N-and S-heterocyclic polycyclic aromatic hydrocarbons. Volume 103. IARC monographs on the evaluation of carcinogenic risks to humans. (3) CHEMINFO (2015) Canadian Centre of Occupational Health and Safety, Hamilton (Ontario) Canada Code of SDS: For information: CA U DRU SS FS 044 1-800-356-3521 (U.S.A.) I 800 567-1492 (Canada) The Safety Data Sheets of SOPREMA are available on Internet at the following site: www.soprema.us and www.soprema.ca Update justification: Oxidized bitumen added (sections II and III). GHS Forn1at. To the best of our knowledge, the information contained herein is accurate. However, neither the above named supplier nor any of its subsidiaries assumes any liability whatsoever for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazards that exist. SBS Modified Bitumen Waterproofing Membrane Revision date: April 30, 2015 Page4 of4 JOB COPY Soprema #14 MP Fasteners -Package Quantities Below Order No. -See Below I DESCRIPTION Soprema #14 MP fastener is engineered to provide exceptional performance in a variety of substrates and applications for Soprema Mechanically Fastened SBS Membrane Systems. Fasteners are designed for the attachment of insulation and membrane to steel (18- 22 ga.), wood, and structural concrete. To meet FM requirements, the fastener must penetrate the steel deck three-quarter(¾") inch. Minimum penetration is one (1 ") inch into wood, three-quarter(¾") inch through wood that is less than three-quarter(¾") inch thick and one and one-quarter (1 ¼") inch into concrete. When installing in concrete, pre-drill using a seven-thirty-second (7/32") inch drill bit and drill pilot hole one-half(½") inch deeper than the required embedment. Install the fastener using a clutch-driven drill motor with a maximum 1500 RPM. The #14 MP Fastener offers these advantages: • Superior pullout performance and ease of application • Specific designed thread for increased back-out resistance • FM Approvals, ICC/ES, Miami-Dade County, Florida State-Wide Approval • Approved for steel, wood and concrete decks • Soprema's flexibility to supply warranted fasteners based on the authorized Soprema roofing applicator's preferred fastener request or applicator tools used • Used with Soprafix and UNILAY Mechanically Fastened Systems lcoMP0s1T10N & PACKAGING Soprema supplied #14 MP Fastener is case hardened carbon steel and use specific head, shank and thread diam- eters, point types and head styles meeting FM Approvals corrosion and simulated wind uplift criteria requirements. Fastener Size #14 MP Fastener Qty. I Pail** Part Number Fastener Size #14 MP Fastener Qty./ Pail** Part Number 1-1/4" F1011 1000 5" F1019 1000 1-1/2" F1012 1000 6" F1020 1000 2" F1013 1000 7" F1021 500 2-1/2" F1014 1000 8" F1022 500 -3" F1015 1000 9" F1023 250 3-1/2" F1016 1000 10" F1024 250 4" F1017 1000 12" F1025 250 4-1/2" F1018 1000 •• Each pail contains one (1) #3 Phillips Head drive bit I WARRANTY Soprema supplies Soprafix #14 MP Fasteners to authorized Soprema roofing applicators and are included in Soprema Project Warranty Agreement offerings. 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX: (330) 334-4289 General product information is provided on this Product Data Sheet. The physical property values reported here are based on testing conducted under controlled laboratory condttions according to accepted test standards. JOB COPY . PR ODUCT DATA S HEET s Soprema 2.4-lnch Seam plate -1000 / Pail I DESCRIPTION Soprafix Membrane 2.4-inch Seam Plates are engineered to provide exceptional performance when used in specific Soprafix or Unilay mechanically fastened SBS Roof Assemblies. The Soprafix 2.4-inch seam plate has engineered 'scoops' that allow the plate to get excellent grip of the membrane without cutting into it with sharp barbs. It is the installer's responsibility to know the Soprafix system being installed, which Soprafix fastening components are required, where and how often these parts are placed within the System. Unless otherwise noted in the Soprafix Approved Details, the installer must center the required Soprafix Seam Plate down the middle of the mechanically fastened side lap of the specified Soprafix membrane. Soprema #15 or #14 Fasteners (or other approved) are installed into the Soprafix Stress Plate according to the applicable Fastening Pattern(s). The 2.4-lnch Soprafix Seam Plate offers these advantages: Labor savings with increased membrane rupture performance and resistance (pull-over) Included in Soprema Project Warranty Agreement offerings Soprema's flexibility to supply warranted fasteners and stress plates based on authorized Soprema roofing applica_tor's preferred requests See current FM Approvals, ICC/ES, Florida State Wide Product Approval and Miami-Dade County Product Approval for Approved Roof Assembly combinations lcoMP0s1r10N & PACKAGING Order No. F1059 Soprema supplied Soprafix Plates are manufactured from heavy gauge galvalume with special designed reinforcing ribs. All Soprafix Plates meet building code and FM Approvals corrosion and simulated wind uplift criteria requirements . lwARRANTY Soprema supplies Soprafix Stress Plates to authorized Soprema roofing applicators and are included in Soprema Project Warranty Agreement offerings. Increased Soprafix Stress Plate and fastener layout densities may be required for Wind Warranty Riders or when elevated roof velocity pressures are encountered on specific projects. 310 QUADRAL DRIVE • WADSWORTH, OHIO 44281 • TEL.: (330) 334-0066 • TOLL FREE: (800) 356-3521 • FAX : (330) 334-4289 General product information is provided on this Product Data Sheet. The physical property values reported here are based on testing conducted under controlled laboratory condttions according to accepted test standards . Sy s t e m I De c k In s u l a t i o n an d / o r No . (N o t e 1) Th e r m a l Ba r r i e r Mi n . 22 ga ., ty p e B, Gr a d e Mi n . 1. 5 - i n c h , On e or S- 2 2 8 . I 33 st e e l at ma x . 6 ft sp a n s mo r e l ay e r s , an y at t a c h e d 6- i n c h o .c. wi t h TR A X X / 5 sc r e w s co m b i n a t i o n I Mi n . 22 ga ., ty p e B, Gr a d e Mi n . 1. 5 -in c h , On e or S- 2 2 9 . mo r e la y e r s , an y 80 st e e l co m b i n a t i o n Mi n . 1. 5 - i n c h , On e or 5- 2 3 0 . I ~~ n . 22 1 ga . , ty p e B , Gr a d e I mo r e la y e r s , an y st ee co m b i n a t i o n Mi n . 22 ga . , ty p e B , 5- 2 3 1 . I Gr a d e 80 st e e l 5- 2 3 2 . I Mi n . 22 ga ., ty p e B, Gr a d e 80 st e e l 5- 2 3 3 . I Mi n . 22 ga ., ty p e B , Gr a d e 80 st e e l 5 -23 4 . I Mi n . 22 ga ., ty p e B , Gr a d e 80 st e e l 5 -23 5 . I Mi n . 22 ga ., ty p e B, Gr a d e 33 st e e l Mi n . 22 ga ., ty p e B , 5- 2 3 6 . I Gr a d e 33 st e e l 5- 2 3 7 . I Mi n . 22 ga ., ty p e B, Gr a d e 33 st e e l Mi n . 22 ga ., ty p e B , S- 2 3 8 . I Gr a d e 80 st e e l NE M O ET C , LL C Ce r t i f i c a t e of Au t h o r i z a t i o n #3 2 4 5 5 Pr e p a r e d by : Ro b e r t Ni e m i n e n , PE -59 1 6 6 1 Mi n . 1. 5 - i n c h , On e or mo r e la y e r s , an y co m b i na t i o n 1 Mi n . 1. 5 - i n c h , On e or mo r e la y e r s , an y co m b i n a t i o n 1 Mi n . 1. 5 - i n c h , On e or mo r e la y e r s , an y co m b i n a t i o n 1 Mi n . 1. 5 - i n c h , On e or mo r e la y e r s , an y co m b i n a t i o n 1 Mi n . 1. 5 - i n c h , On e o r mo r e la y e r s , an y co m b i n a t i o n 1 Mi n . 1. 5 -in c h , On e or mo r e la y e r s , an y co m b i n a t i o n 1 Mi n . 1 .5- i n c h , On e or mo r e la y e r s , an y co m b i n a t i o n 1 Mi n . 1. 5 - i n c h , On e or mo r e la y e r s , an y co m b i n a t i o n JO B CO P Y RE R O O F (T E A R - O F F ) OR RE C O V E R HE D SO P R A F I X , BO N D E D RO O F CO V E R Ba s e M e m br a n e Ba s e Fa s t e n e r s S pa c i n g Tr u f a s t #1 5 EH D wi t h Tr u f a s t 2. 4 in . SO P R A F I X Ba s e 61 0 , 61 1 , 61 2 , Sc o o p Se a m Pl a t e s or So p r e m a #1 5 HD 12 - i n c h o .c . wi t h i n 4- i n c h 61 4 or 62 2 w i de , he a t - w e l d e d la p s wi t h So p r e m a 2. 4 " Se a m Pl a t e SO P R A F I X Ba s e 61 0 , 61 1 , 6 1 2 , Tr u f a s t #1 4 HD wi t h Tr u f a s t 2. 4 i n. 12 - i n c h o. c . wi t h i n 4- i n c h 61 4 or 62 2 Sc o o p Se a m Pl a t e s or So p r e m a #1 4 MP wi d e , he a t -we l d e d la p s wi t h So p r e m a 2. 4 " Se a m Pl a t e SO P R A F I X Ba s e 61 0 , 61 1 , 61 2 , Tr u f a s t #1 4 HD wi t h Tr u f a s t 2. 4 in . 12 - i n c h o. c . wi t h i n 4- i n c h 61 4 or 62 2 Sc o o p Se a m Pl a t e s or So p r e m a #1 4 MP wi d e , he a t - w e l d e d la p s wi t h So p r e m a 2. 4 " S e a m Pl a t e So p r e m a #1 5 EL wi t h SO P R A F I X 2 3/ 8 I1 2 - i n c h o. c . wi t h i n 5- i n c h Un i l a y in . SB St r e s s Pl a t e s wi d e he a t - w e l d e d la p s Tr u f a s t #1 5 EH D wi t h Tr u f a s t 2. 4 in . 12 - i n c h o .c. wi t h i n 4 -in c h SO P R A F I X Ba s e 62 1 or 62 2 Sc o o p Se a m Pl a t e s or So p r e m a #1 5 HD wi t h So p r e m a 2. 4 " Se a m Pl a t e wi d e , he a t - w e l d e d la p s Tr u f a s t #1 5 EH D wi t h Tr u f a s t 2. 4 in . 12 - i n c h o. c . wi t h i n 4- i n c h SO P R A F I X Ba s e 61 4 Sc o o p Se a m Pl a t e s or So p r e m a #1 5 HD wi d e , he a t - w e l d e d l ap s wi t h So p r e m a 2 .4" Se a m Pl a t e Tr u f a s t #1 5 EH D wi t h Tr u f a s t 2. 4 in . 12 - i n c h o .c. wi t h i n 4- i n c h SO P R A F I X Ba s e 61 4 Sc o o p Se a m Pl a t e s or So p r e m a #1 5 HD wi t h So p r e m a 2 .4" Se a m Pl a t e wi d e , he a t - w e l d e d la p s Tr u f a s t #1 5 EH D wi t h Tr u f a s t 2 in . I SO P R A F I X Ba s e 62 1 o, 62 2 I Ba , b e d Me t a l Se a m Pl a t e s o, T, u f a s t 6- i n c h o. c . wi t h i n 4- i n c h wi d e , 2. 4 in . Sc o o p Se a m Pl a t e s or So p r e m a #1 5 HD wi t h So p r e m a 2 " Se a m Pl a t e or he a t - w e l d e d la p s So p r e m a 2. 4 " Se a m Pl a t e Tr u f a s t #1 5 EH D wi t h Tr u f a s t 2 in . I SO P R A F I X Ba s e 61 0 , 6 1 1 , 6 1 2 , I Ba < b e d Me t a l Se a m Pl a t e s o, T, u f a s t 1 6 . h . h . h .d . -m e o .c. wi t In 4- i n c wI e , 61 4 or 62 2 2. 4 in . Sc ~ o p Se a m Pl a t e s or So p r e m a he a t - w e l d e d la s #1 5 HD wi t h So p r e m a 2" Se a m Pl a t e or p So p r e m a 2. 4 " Se a m Pl a t e Tr u f a s t #1 5 EH D wi t h Tr u f a s t 2 in . I SO P R A F I X Ba s e 61 0 , 61 1 , 61 2 , I Ba < b e d Me t a l Se a m Pl a t e s o, T, u f a s t 6- i n c h o .c . wi t h i n 4- i n c h wi d e , 2. 4 in . Sc o o p Se a m Pl a t e s or So p r e m a 61 4 or 62 2 #1 5 HD wi t h So p r e m a 2" Se a m Pl a t e o r he a t - w e l d e d la p s So p r e m a 2. 4 " Se a m Pl a t e I SO P R A F I X Ba s e 62 1 o , 62 2 Tr u f a s t #1 4 HD or #1 5 EH D wi t h I T, u f a s t 2 ;n . Ba , b e d Me t a l Se a m Pl a t e s 6- i n c h o .c. wi t h i n 4- i n c h wi d e , or So p r e m a #1 4 or #1 5 HD wi t h he a t - w e l d e d la p s So p r e m a 2" Se a m Pl a t e 5T H ED I T I O N (2 0 1 7 ) FB C NO N - H V H Z EV A L U A T I O N So p r e m a Mo d i f i e d Bi t u m e n Ro o f Sy s t e m s ; (8 0 0 ) 35 6 - 3 5 2 1 8NEMOletc. Roof Cover (Note 15) I MDP Ply I Cap I (psf) I (O p t i o n a l ) SBS-TA-F I SBS-TA-F I -75 .0 El a s t o p h e n e SP or SP 3 .0 or Sopralene 180 SP o r I SBS-CAl I -75 .0 18 0 S P 3.5 , torch-applied (O p t i o n a l ) SBS-TA-F I SBS-TA-F I -75.0 I None I None I -82.5 I None I SBS-CAl I -97.5 El a s t o p h e n e SP or SP 3 .0 or Sopralene 180 SP or I SBS-CAl I -97.5 18 0 SP 3.5, torch-applied (O p t i o n a l ) SBS-TA-F I SBS-TA-F I -97.5 I None I SBS-CAl I -112 .5 I El a s t o p h e n e SP o, SP 3 .0 or Sopralene 180 SP or I SBS-CAl I -112 .s 18 0 SP 3 .5 , torch-applied I (O p t i o n a l ) SBS-TA-F I SBS-TA -F I -112.5 I None I SBS-CAl I -120.0 Ev a l u a t i o n Report S35000 .12 .10-R25 for FL3915-R27 Revision 25 : 02/12/2019 Appendix 1 , Page 53 of 117 FLASHING CAP SHEET POLYESTER REINFORCED FLASHING BASE PLY FASTENER BASE SHEET/ANCHOR SHEET COVERBOARD INSULATION INSULATION BASE SHEET/ANCHOR SHEET THERMAL BARRIER VAPOR RETARDER/AIR BARRIER ASSEMBLY NOTES: 1. SOP REMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS} AND SAFETY DATA SHEETS (SOS} FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERT A RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS. SOPREMA® US CORPORA TE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 PROJECT: TITLE: 2 PLY SBS MEMBRANE, INSULATED, ROOF ASSEMBLY DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: DATE: 10.26.2017 DRAWING NUMBER: SCALE: NTS US.RSBS.01.01 USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. BASE SHEET/ANCHOR SHEET/BACKER PLY CURB VAPOR RETARDER/AIR BARRIER/BACKER PLY NON-REMOVABLE CURB COUNTERFLASHING SHEET METAL COUNTERFLASHING FLASHING CAP SHEET POLYESTER REINFORCED FLASHING BASE COVERBOARD INSULATION INSULATION VAPOR RETARDER/AIR BARRIER INSULATION DA3[ 81 l[[T/ANCI IOR 81 l[[T NOTES: 1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SDS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA GERTA RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS 4. FLASHING PLIES MUST EXTEND VERTICALLY A MINIMUM OF 8' FROM ROOF SURFACE. FLASHING PLIES EXTENDING VERTICALLY MORE THAN 24' FROM ROOF SURFACE MUST BE ADHERED AND MECHANICALLY FASTENED ALONG THE TOP LEADING EDGE. REFER TO PUBLISHED DOCUMENTATION. 5. FOR 90° TRANSITIONS, FLASHING PLIES MUST MEET THE FOLLOWING REQUIREMENTS: HEAT WELD POLYESTER REINFORCED FLASHING BASE PLIES. HEAT WELD POLYESTER REINFORCED GRANULE FLASHING CAP SHEET, OR HEAT WELD FOIUFILM CLAD FLASHING CAP SHEET. SOPREMA US CORPORATE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 ~ PROJECT: TITLE: 2 PLY SBS MEMBRANE, INSULATED CURB WITH NON-REMOVABLE COUNTERFLASHING DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: 7.9.2015 DRAWING NUMBER: SCALE: NTS US.RSBS.05.01 DATE: USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. TERMINATION BAR FASTEN AT 8' O.C. MAXIMUM ALONG HORIZONTAL EDGE VAPOR RETARDER/AIR BARRIER/ BASE SHEET/ANCHOR SHEET/ EXTEND FLASHING MINIMUM OFl3X~t•mill" MINIMUM OF 3' BEYOND FA EXTEND FLASHING CAP SHEET A MINIMUM OF 1' eey1\¾@Jfj_L,@rll4&1fi:@:qli~ MINIMUM OF 1' BEYOND FLASHING BASE PLY COVERBOARD SOPRAMASTIC SP1 BASE SHEET/ANCHOR SHEET NOTES: COUNTERFLASHING FLASHING CAP SHEET POLYESTER REINFORCED FLASHING BASE PLY BASE PLY BASE SHEET/ANCHOR SHEET \_ VAPOR RETARDER/AIR BARRIER CAP SHEET THERMAL BARRIER 1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SDS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERT A RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS 4. FLASHING PLIES MUST EXTEND VERTICALLY A MINIMUM OF 8' FROM ROOF SURFACE. FLASHING PLIES EXTENDING VERTICALLY MORE THAN 24" FROM ROOF SURFACE MUST BE ADHERED AND MECHANICALLY FASTENED ALONG THE TOP LEADING EDGE. REFER TO PUBLISHED DOCUMENTATION. 5. FOR 90° TRANSITIONS, FLASHING PLIES MUST MEET THE FOLLOWING REQUIREMENTS: HEAT WELD POLYESTER REINFORCED FLASHING BASE PLIES. HEAT WELD POLYESTER REINFORCED GRANULE FLASHING CAP SHEET, OR HEAT WELD FOIUFILM CLAD FLASHING CAP SHEET. Ill) SOPREMA US CORPORATE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 PROJECT: TITLE: 2 PLY SBS MEMBRANE, INSULATED WALL FLASHING WITH SURFACE MOUNTED COUNFERFLASHING DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: 7.14.2015 DRAWING NUMBER: SCALE: NTS US.RSBS.04.03 DATE: USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. CLEAN AND PREPARE PENETRATION SURFACE CAP SHEET POL VESTER REINFORCED FLASHING NOTES: EXTEND FLASHING BASE PLY A MINIMUM OF 3" BEYOND FASTENER PLATES BASE SHEET/ANCHOR SHEET BASE SHEET/ANCHOR SHEET VAPOR RETARDER/AIR BARRIER THERMAL BARRIER EXTEND REINFORCING FABRIC A MINIMUM OF 4" BEYOND THE ROOF SURFACE EXTEND REINFORCING FABRIC A MINIMUM OF 8" BEYOND THE PENETRATION REINFORCING FA □RIC INSULATION 1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SOS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERT A RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS. 4. SOPREMA RECOMMENDS 8 INCH VERTICAL FLASHING HEIGHTS. FLASHING DETAILS SHOWN INCLUDE MINIMUM DIMENSIONS TO MEET WARRANTY REQUIREMENTS. CONTACT SOPREMA FOR ADDITIONAL REQUIREMENTS. 5. DO NOT APPLY ALSAN RS LIQUID APPLIED SIYSTEMS OVER SBS MODIFIED BITUMEN MATERIALS ADHERED USING COLPLY OR COLPL Y MODIFIED ADHESIVES OR CEMENTS. SELF ADHERE, HOT AIR WELD OR TORCH APPLY THE SBS MODIFIED BITUMEN MEMBRANE AND FLASHINGS IN ALL AREAS WHERE ALSAN RS WILL BE APPLIED. Q;) SOPREMA US CORPORATE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 PROJECT: TITLE: 2 PLY SBS MEMBRANE, INSULATED, PENETRATION WITH LIQUID FLASHING DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: DATE: 4.18.2016 DRAWING NUMBER: SCALE: NTS US.RSBS.06.03 USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOP REMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. CLEAN AND PREPARE PENETRATIONS AS REQUIRED SOPREMA PITCH POCKET FILLERAT2"THICK~ NON-SHRINK GROUT MINIMUM 4" FLANGE PRIMED ON BOTH SIDES, METAL FLANGE SET IN A FULL BED OF SOPRAMASTIC SBS MASTIC. INSULATION INSULATION INSULATION NOTES: DECK PENETRATION POCKET MINIMUM 4" HIGH, SOLDER/WELD ALL SEAMS POLYESTER REINFORCED FLASHING BASE PLY INSTALL FASTENER PLATE A MINIMUM OF 1~,~~~ii~~:NGE EXTEND FLASHING BASE PLY A MINIMUM OF 3" BE'YONn FASTFNFR Pl ATF BASE PLY BASE SHEET/ANCHOR SHEET VAPOR RETARDER/AIR BARRIER BASE SHEET/ANCHOR SHEET THERMAL BARRIER 1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SOS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERT A RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS. SOPREMA® US CORPORA TE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 PROJECT: TITLE: 2 PLY SBS MEMBRANE, INSULATED PENETRATION POCKET DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: DATE: 5.11.2015 DRAWING NUMBER: SCALE: NTS US.RSBS.06.02 USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. EXTENB~AnLJMll,j{IR/li,//MAANIMUM OEllF/4' BEYOND REINFORCING FABRIC CLEAN AND PREPARE PENETRATION SURFACE INSTALL FASTENER PLATE AROUND PENETRATION SPACED A MAXIMUM OF 12' APART NOTES: EXTEND FLASHING BASE PLY A MINIMUM OF 3' BEYOND FASTENER PLATES BASE SHEET/ANCHOR SHEET BASE SHEET/ANCHOR SHEET VAPOR RETARDER/AIR BARRIER EXTEND REINFORCING FABRIC A MINIMUM OF 4" BEYOND THE ROOF SURFACE EXTEND REINFORCING FABRIC FINGERS A MINIMUM OF 2" BEYOND THE PENETRATION EXTEND REINFORCING FABRIC A MINIMUM OF 8' BEYOND THE PENETRATION EXTEND ALSAN ~MN()MI.M.INIMUM OF 1143131'3'.'MilDIREfilFJB~(S~C COVERBOARD 1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SDS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA GERTA RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS. 4. SOPREMA RECOMMENDS 8 INCH VERTICAL FLASHING HEIGHTS. FLASHING DETAILS SHOWN INCLUDE MINIMUM DIMENSIONS TO MEET WARRANTY REQUIREMENTS. CONTACT SOPREMA FOR ADDITIONAL REQUIREMENTS. 5. DO NOT APPLY ALSAN RS LIQUID APPLIED SIYSTEMS OVER SBS MODIFIED BITUMEN MATERIALS ADHERED USING COLPLY OR COLPL Y MODIFIED ADHESIVES OR CEMENTS. SELF ADHERE, HOT AIR WELD OR TORCH APPLY THE SBS MODIFIED BITUMEN MEMBRANE AND FLASHINGS IN ALL AREAS WHERE ALSAN RS WILL BE APPLIED. SOPREMA~ US CORPORA TE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 PROJECT: TITLE: 2 PLY SBS MEMBRANE, INSULATED, PLUMBING VENT WITH LIQUID FLASHING DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: DATE: 4.18.2016 DRAWING NUMBER: SCALE: NTS US.RSBS.06.01 b USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. PLUMBING VENT BASE SHEET/ANCHOR SHEET BASE SHEET/ANCHOR SHEET VAPOR RETARDER/AIR BARRIER NOTES: SOFT METAL PIPE FLASHING MINIMUM 4" FLANGE PRIMED ON BOTH SIDES, METAL FLANGE SET IN A FULL BED OF SOPRAMASTIC SBS MASTIC CAP SHEET POLYESTER REINFORCED FLASHING BASE PLY FASTEN BASE PLY AROUND PIPE ~k-1:~N~R~sAl~~~ff ~lv'lfMMUM OF 3" B~nIft,t,.~~l~~t~~~ MINIMUM OF 3" BEYOND FASTENER PLATE COVERBOARD INSULATION 1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SDS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERT A RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS. SOPREMA® US CORPORA TE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 PROJECT: TITLE: 2 PLY SBS MEMBRANE, INSULATED PLUMBING VENT W/ SOFT METAL FLASHING DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: DATE: 5.11.2015 DRAWING NUMBER: SCALE: NTS US.RSBS.06.01 a USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. NOTES: MITER CUT FLASHI BASE PLY AS SHOW EXTEND FLASHING CAP SHEET A MINIMUM 8RlI:llmlBl.lNEH1HS COOBBe[lFA"M\SININ9 DETAIL OF 3" AROUND THE CORNER OF FLASHING DETAIL l~~~~@ts~ FLASHING BASE PLY EXTEND FLASHING CAP SHEET A MINIMUM OF 1' BEYOND ~llm!.l',lf«t\~~l~LY A MINIMUM OF 1' BEYOND -CAP ~~@Ef l YING Fl ASHING RASF Pl Y 1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SOS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERTA RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS. SOPREMA® US CORPORA TE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 PROJECT: TITLE: 2 PLY SBS MEMBRANE INSIDE CORNERS DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: DATE: 3.14.2016 DRAWING NUMBER: SCALE: NTS US.RSBS.02.04 USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. FLASHING BASE PLY STEP 1 FLASHING BASE PLY NOTES: EXTEND FLASHING BASE PLY A MINIMUM fl:F~~@~Erf0'f:f!~~oETA1L OF 3" AROUND THE CORNER OF FLASHING DETAIL TERMINATE FLASHING BASE PLY A\~2~~JfT~m~~m~i~~l~ty- AT CORNER OVi™lc!tJri!l~~ING MITE~r~~ FLASHING CAP SHEET EXTEND FLASHING CAP SHEET A MINIMUM 8fx't1MrH--Llj,_~~ttJG~r ~~~ETAIL FLl?fHrN~~RWfil-i~~T CORNER OF FLASHING DETAIL CAP SHEET BASE PLY FLASHING BASE PLY FLASHING BASE PLY 1. SOPREMA DETAIL DRAWINGS: REFER TO SOP REMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SOS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERTA RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS. SOPREMA US CORPORATE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 <8J PROJECT: TITLE: 2 PLY SBS MEMBRANE OUTSIDE CORNERS DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: DATE: 3.16.2016 DRAWING NUMBER: SCALE: NTS US.RSBS.02.03 USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. ROOF EDGE SYSTEM WEATHERPROOF MEMBRANE BASE SHEET/ANCHOR SHEET/ CANT EXTEND FLASHING MINIMUM OFi3l<iB~~ljfij!)W MINIMUM OF 3" BEYOND FA EXTEND FLASHING CAP SHEET A MINIMUM OF 1" eeyl3¾1§)ifi.~~~qlt~ MINIMUM OF 1" BEYOND FLASHING BASE PLY COVERBOARD BASE SHEET/ANCHOR SHEET ,,-VAPOR RETARDER/AIR BARRIER/BACKER PLY FLASHING CAP SHEET POLYESTER REINFORCED FLASHING BASE PLY BASE PLY CAP SHEET THERMAL BARRIER BASE SHEET/ANCHOR SHEET VAPOR RETARDER/AIR BARRIER NOTES: 1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SDS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERTA RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS 4. FLASHING PLIES MUST EXTEND VERTICALLY A MINIMUM OF 8" FROM ROOF SURFACE. FLASHING PLIES EXTENDING VERTICALLY MORE THAN 24" FROM ROOF SURFACE MUST BE ADHERED AND MECHANICALLY FASTENED ALONG THE TOP LEADING EDGE. REFER TO PUBLISHED DOCUMENTATION. 5. FOR 90° TRANSITIONS, FLASHING PLIES MUST MEET THE FOLLOWING REQUIREMENTS: HEAT WELD POLYESTER REINFORCED FLASHING BASE PLIES. HEAT WELD POLYESTER REINFORCED GRANULE FLASHING CAP SHEET, OR HEAT WELD FOIUFILM CLAD FLASHING CAP SHEET. SOPREMA® US CORPORA TE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 PROJECT: TITLE: 2 PLY SBS MEMBRANE, INSULATED PARAPET WALL WITH METAL COPING DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: 7.8.2015 DRAWING NUMBER: SCALE: NTS US.RSBS.03.04 DATE: USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. CAP SHEET POLYESTER REINFORCED FLASHING BASE PLY SOPRAMASTIC SP1 ROOF EDGE SYSTEM MINIMUM 4' FLANGE PRIMED ON BOTH SIDES, METAL FLANGE SET IN A FULL BED OF SOPRMASTIC SBS MASTIC VAPOR RETARDER/AIR BARRIER BASE SHEET/ANCHOR SHEET NOTES: DECK EXTEND FLASHING BASE PLY A MINIMUM OF 3" BEYOND MET AL FLANGE BASE PLY BASE SHEET/ANCHOR SHEET COVERBOARD THERMAL BARRIER 1. SOP REMA DETAIL DRAWINGS: REFER TO SOP REMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SOS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA GERTA RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS. SOPREMA® US CORPORA TE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 PROJECT: TITLE: 2 PLY SBS MEMBRANE, INSULATED DRIP EDGE DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: REVISION: DATE: DATE: 4.23.2015 DRAWING NUMBER: SCALE: NTS US.RSBS.03.02 USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING.