Loading...
1114 E Sandpiper Ln Fence Submittal Building Permit Application Updated 10,19/18 Y.,. „ City of Atlantic Beach Building Department **ALL INFORMATION 1 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRA*' Phone: (904) 247-5826 Email: Buiiding-Dept@coab.us IS REQUIRED. Job Address: I f I y 5ei ,�P;.r.cv• LA k A+IGnr: cc. 11321-33Permit Number: Legal Description 0)00 S;y ylti «m,�y RE# 1723714 -527 5 Valuation of Work (Replacement Cost)$ 190() Heated/Cooled SF Non-Heated/Cooled _ • Class of Work: ❑New ❑Addition DAlteration .i (Repair DMove ❑Demo ❑Pool ❑Wind P E ' • Use of existing/proposed structure(s): ❑Commercial .rkttesidential AUG 0 3 2021 • If an existing structure,is a fire sprinkler system installed?: ❑Yes .kNo • Will tree(s) be removed in association with proposed project? DYes(must submit separate Tree Wi Describe in detail the type of work to be performed: —� Re kcic,Ny c-xe�� ) I.— o-t j Florida Product Approval# _ for multiple products use product approval form Property Owner Information Name CAddress If I`1 S4,dP'rU' L►n City __ A+Icer1+:c. IY..44 State PI Lip 3Z.2-33 Phone 112( ZisO 31jO E-Mail S 5 c• to C.1«rL mot i l. Gam►, Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) Contractor Information /� Name of Company SuPr�r(cv- f emcc c -4 Ra)l Qualifying Agent �ac(, f eye'^ Address S970 [(yl,vay /. '- _City T.icLsww;l l c. State F 1 Zip 31254 Office Phone `f01-1 l;s•3 G 31-19 Job Site Contact Number _ State Certification/Registration#_ [ Cs `rSS`f — E-Mail &owl e P[c' {Ce mac; J uc,I4Sony;(I� . con, Architect Name&Phone# Engineer's Name& Phone# Workers Compensation Insurer dee +-c.d rAa-fta.tl OR Exempt 0 Expiration Date g/ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand thata separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts, state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING Y • OTICE COMMENCEMENT. - (Signature of Owner or Agent) (S •nature of Contractor) Signed and sworn to(or affirmed) before me this 3day of signed and sworn to(or affirmed)before me this Zcrday of u.S4- ,-Aar • by �'dlnv. c,( -- 314 • 2cr7-1 - Qpoia V (��d�•»-��,4 N•+• %'1 `� (Signature of Notary) '4 Vic,JANMAURICIO WALKER ROBERTSON • • ,. MY COMMISSIONS HH 009325 4013°^ Notary Public State of Florida [ I Personally Known OR --.;;;.• •". - EXPIRES:June 11,2024 personally Known OR Bntani M Norman OF F��,per• • • My Commission HH 011346 ,[iJ'�roduced Identification 13"edThruN°taryPublic UnderwtiMra ` l l Produced Identification ?apdF Expires 06/16!2024 Type of Identification: Sr. -e. ccen. C,. Type of identification: -- _ _ _ f-" ,.; , Fence Addendum Updated1/14/2021 f ...... City of Atlantic Beach Building Department !,, 800 Seminole Road, Atlantic Beach, FL 32233 PERMIT# _ Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: Date: t lit Sw414dr- lam, E, Ai(artier 6eu k FC- #- j A- 3 , ,20a Property Type: Lot Type/ Features: 'Residential .One Street frontage (interior lot) ❑ Commercial ❑ More than one street frontage(corner lot,through lot, etc.) ❑ Swimming Pool Fence Material: Fence Height (select all that apply): 'W Wood ❑ Four Foot(4ft) ❑ Chain Link ',Six Foot(6ft) ❑ Vinyl ❑ Other ❑ Block/Stone (Plan details required for footings and/or retaining walls) ❑ Other Fence Location: Please submit an accurate and current boundary survey showing all existing improvements(including building footprint, driveway, swimming pool,etc.) and location of fence/wall and any gates. Plan details required for block wall footings and/or retaining walls and any portion or fencing above 6ft in height. Will the fence be built in an easement? ❑ Yes (must submit separate Revocable Encroachment Agreement) X.No Will tree(s) be removed in association with proposed project? ❑ Yes(must submit separate Tree Removal Permit) >1.,No Conditions of Approval: • Roll off container company must be on City approved list. Roll off container cannot be placed on City right-of-way. • All old fencing and debris must be removed from job site by contractor or homeowner. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MAP SHOWING BOUNDARY SURVEY OF LOT 54, AS SHOWN ON MAP OF SELVA LINKSIDE UNIT 1 AS RECORDED IN PLAT BOOK 44, PAGES 23 & 23A, OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLA. CERTIFIED TO: JELISSE M. MARRERO; WATSON TITLE SERVICES OF N. FL., INC.; OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY; BANK OF ENGLAND SCALE: 1"=-30' DATE: 12/16/19 LOT_57 �Z LOT 56 .0 r, I^c° or Op f 1 1 J N (JI P.C. ND. 3/8., LR. NO CAP IC) CURVE C-1(ACT) 1 N S24'09'35"W �,1 CH=11.21' LOT 55 �� vl1::.5.0) A=11.21' IR=130.51' 1 �� '1 0G' A=4'55'24" 81.54'(P) N83'42'00"E(ACT) 81.71'(ACT) ^.� CURVE C-1(P) 3'47'01"E( m S23'31'31"W 9L NS 6' WOOD FENCE o CH=11.17' (TYPICAL) %i -A ---= R=130.51' m . '• _ / -WATER METER 9 1: ND. 1/2" LP.a 10.0 p rNi C-1 0.8' LBt 14 ° 5o. .0' W 3.3'X3.3' CONC. PAD I o s.t' / N� CURVE C-2(ACT) AIR CONDITIONER 2 6. 27.3 CONC. x / �o S54'59'06"W • PAT10 / i:. -, CH=24.20' o z 'E'D Z 1—STORY w / A=25.26' z r rn COQUINA u x /9B ,� R=25.00' �, z 1. x #1114 // 0a° A=57'53'38" p 3'4 / �ry 0) CURVE C-2(P) N -0 Co O N 4 1o.6' 7 4C/ Lf) 0 1.6' /J71�� 554'50'22"W /�.8•, (� Q CH=24.13' G COVERED ' . . . ENTRY .,... . v p N •• DRIVEWAY; ,��cs- �� \ R=25.00' 70 • Q Q cZi v1 0 6' 9.6' :./• .: ry�� ,C) _4-) CURVE C-3(ACT) r'n A h S07'09'43"W N b D 7.5' JEA NCO�ry CH=61.81' rn up Z CA EASEMENT/ A=62.40' call v m� N /F 'rig /� R=1 30.51' �+ c- --- SFp�CABLE RISER &=27'23'36" N - sos�. Box CURVE C-3(P) G�`L S07'23'09"W S83'37'13"W(CALC) 2�4 CH=61.75' S83'21'02"W(ACT) �'a��',A R=130.51' 4.29'(ACT) I 4.38'(CALC) I \ THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN BEARINGS BASED ON PLAT AS SHOWN ON THIS MAP THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY. UNDERGROUND FOUNDATIONS/UTILITIES NOT LOCATED THE LOT SHOWN HEREON IS IN FLOOD ZONE "X" AS SHOWN ON FLOOD INSURANCE RATE MAP 1203100408J FOR DUVAL COUNTY, FLORIDA, DATED 11/02/18. C & C LAND SURVEYORS, INC. 774 STATE ROAD 13, STE. 4, ST. JOHNS, FLORIDA 32259 (904) 287-0407 — LICENSED BUSINESS NO. 7390 li ABBREVIATIONS USED ALL MAPPED FEATURES SHOWN HEREON WERE PERFORMED UNDER A = ARC LENGTH N.A.V.D.= NORTH AMERICAN MY DIRECT SUPERVISION AND DIRECTION. THIS MAP/SURVEY • (ACT)= ACTUAL VERTICAL DATUM ith B.R.L= BUILDING MON. = MONUMENT MEETS THE STANDARDS OF PRACTICE ESTABLISHED BY THE II RESTRICTION UNE (P) - PLAT BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS PURSUANT CH = CHORD DISTANCE P.C. = POINT OF CURVATURE TO CHAPTER 472.027 FLORIDA STATUTES AND CHAPTER 5J-17 CONC.= CONCRETE P.C.C. = POINT OF COMPOUND Q. = CENTERLINE CURVATURE FLORIDA ADMINISTRATIVE CODE. III A - DELTA P.I. = POINT OF INTERSECTION ESMT= EASEMENT P.R.C. = POINT OF REVERSE THIS MAP/SURVEY IS NOT VALID F.F.E.= FINISH FLOOR CURVATURE WITHOUT SIGNATURE AND RAISED SEAL ELEVATION P.T. = POINT OF TANGENCY FND. - FOUND R/W = RIGHT OF WAY SAMUEL C. COOLER I.P. = IRON PIPE R = RADUIS I.R. = IRON ROD (R) = RADIAL � rr6/75' LB = OVERHEAD UNE(S)SINES WN = TANGENT / / LB UCENSED BUSINESS (W) = WITNESS S/_.� CALO = CALCULATED TANGENCY SURVEYOR P.N.T. = POINT OF NON PRO AL SURVEYOR & MAPPER NO. LS 6076 F.B. 126:47 DR. BY SCC DIR. D:/DWG/2019 FILE 19-526 ORDER NO. 19-526