06-14-21- Presentation - Sewage Odor & Corrosion Control Programf 41)+ i 'peal op.uenv uowJed soi tn 3!Ignd w e1201d IowoD uolsoiio) vg opo a2ennas 1.Z-14-9 sajnu!W 9IN3WHO` UV ATTACHMENT B Minutes 6-14-21 Need for Odor & Corrosion Control • As sewage ages in the collection system, Hydrogen Sulfide (H2S) is produced • H2S has a rotten egg odor and can be detected as a noxious odor at very low levels • H2S also reacts with moisture in the sewer lines to create Sulfuric Acid which eats away concrete and metal • Most odor complaints are associated with the WWTF and the Lift Stations and gravity sewer lines that receive sewage from a Lift Station • Significant damage has occurred at the headworks of the WWTF and several Lift Stations, manholes & sewer lines ATTACHMENT B Minutes 6-14-21 Need for Odor & Corrosion Control • Primary culprits are the Selva Marina Lift Station and the Buccaneer Master Pump Station • Both stations receive sewage from a large area that has been in the collection system for a long time • PU primary weapon to combat H2S is Hydrogen Peroxide (H2O2) • H2O2 is injected at the Selva Marina Lift Station and downstream of the Buccaneer Master Pump Station near the WWTF • H202 reacts instantly to oxidize H2S to Sulfate which has no odor Selva Marina Forcemain System ATTACHMENT B Minutes 6-14-21 • Most of the sewage generated east of ABCC and Sherry Drive flows to the Selva Marina LS and/or to the 11th St LS • Most odor complaints have been on Selva Marina Drive between ABCC and Seminole Rd and at the 11th St LS • Currently, H202 is injected at this LS • The injection point may be moved to the 11th St LS as the collection system is improved WAST EVVAT E R TREATMENT FACILITY ATTACHMENT B Buccaneer Master Pump=2' Station Forcemain System • Most odor complaints have been from the WWTF where the forcemain discharges in to the headworks • Sewage collected in the Buccaneer Service District (north of Dutton Island Road) mostly flows to the Buccaneer Master PS • H202 is injected in to the Buccaneer forcemain near the WWTF for maximum effectiveness ATTACHMENT B Minutes 6-14-21 Selva Marina LS Odor Control System ATTACHMENT B Minutes 6-14-21 Selva Marina H2O2 Injection Program • H2O2 injection initiated in June 2020 • There were numerous odor complaints prior to startup dating back many years • After startup there have been Zero odor complaints • H2S reduced from 66 ppm to 1.5 ppm, 98% reduction • Using ^'460 gallons of H2O2 /month at a cost of $1,900/month • Monthly cost for equipment rental = $825 • Total MRC = $2,750 • Total Annual Cost = $33,000 ATTACHMENT B Minutes 6-14-21 Buccaneer H202 Injection Program • H2O2 injection in to the Buccaneer FM initiated in December 2020 • No odor complaints received after startup • H2S levels have been reduced to level where corrosion at the headworks should not be a continuing concern • H2S reduced from 72 ppm to 4.8 ppm, 93% reduction • Using ^'1,065 gallons of H2O2 /month at a cost of $4,460/month • Monthly cost for equipment rental = $825 • Total MRC = $5,300 • Total Annual Cost = $63,400 ATTACHMENT B Minutes 6-14-21 Looking Forward... • Continue to adjust & optimize H2O2 dosage to reduce costs • Optimize H2O2 injection points to maximize benefits • Current total cost = $96,300/yr • FY 21/21 project cost w/ inflation =^'$125,000/yr • Based on initial estimates, reduced maintenance costs should be somewhat equivalent to annual odor/corrosion control costs • With an older inefficient collection system and a WWTF in the heart of the City, we recommend that this program be continued