No preview available
 /
     
1691 Atlantic Beach Dr POOL21-0032 pool permitOWNER:ADDRESS:CITY:STATE:ZIP: SHABBY CHIC HOLDINGS LLC 3948 3rd ST JACKSONVILLE BEACH FL 32250 COMPANY:ADDRESS:CITY:STATE:ZIP: COASTAL LUXURY OUTDOORS LLC 115 Solana Rd Suite C PONTE VEDRA BEACH FL 32082 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 1375 ATLANTIC BEACH COUNTRY CLUB UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1691 ATLANTIC BEACH DR SWIMMING POOL SWIMMING POOL RESIDENTIAL SWIMMING POOL $30000.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 8/27/2021 PERMIT NUMBER POOL21-0032 ISSUED: 8/27/2021 EXPIRES: 2/23/2022 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $205.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $102.50 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.61 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.08 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $515.19 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 3 PUBLIC WORKS POOL WELLPOINT INFORMATIONAL Notes: Pool Wellpoint (if used) must discharge into vegetated area 10 foot minimum from street or drainage feature (swale, structure or lagoon). 4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 6 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 7 PUBLIC WORKS DECKING REMOVED INFORMATIONAL Notes: All old decking and debris must be removed from job site by Contractor. 8 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 2 of 2Issued Date: 8/27/2021 PERMIT NUMBER POOL21-0032 ISSUED: 8/27/2021 EXPIRES: 2/23/2022 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION POOL21-0032 POOL21-0032 Project Name: Shabby Chic Holdings, LLC Date: 8-13-2021 Address: 1691 Atlantic Beach Dr Atlantic Beach, FL 32233 Construction: Inground concrete swimming pool Occupancy Class: Single Family Dwelling Group R-3 Existing Lot Coverage: Lot Square Footage: 7,200 sq ft House: 2,587sq ft Driveway & front walk: 448 sq ft AC pad and Wall: 17 sq ft Existing Paver Patio with Firepit: 838 Total Lot Coverage: 3,873 sq ft Percentage: 53.8% Revised Lot Coverage Lot Square Footage: 7,200 sq ft House: 2,587sq ft Driveway & front walk: 448 sq ft Remove Existing Paver: -838 sq ft AC Pad, Pool Equipment Pad and Wall: 29 sq ft Existing Fire Pit: 13 sq ft New Paver Deck: 310 sq ft New Pool: 297 sq ft = 149 sq ft @ 50% Total Coverage: 3,536 Percentage: 49.1% Index: Cover Letter Notice of Commencement Agent Ltr Permit Application Tree Removal Affidavit Coastal Luxury Outdoors 115 Solana Rd, Suite Ponte Vedra Beach, FL 32082 Office (904) 543-2626 Fax (866) 609-2717 CPC 1458340 POOL21-0032 Proposed Topo Survey Proposed Topo Survey with Pool Permit Construction Drawing Permit Plumbing Drawing Engineered Drawings TDH Data Sheets Lot Coverage Lot - 7,180 House - 2587 sq ft Driveway & Front walkway - 448 sq ft A/C Pad & Wall - 17 sq ft Existing Paver Patio - 838 sq ft Total Lot Coverage = 3,892 = 53.8% Revised Lot Coverage Lot - 7,200 House - 2587 sq ft Driveway & Front walkway - 448 sq ft Remove Existing Paver Patio - 838 sq ft A/C Pad & Wall and pool equipment pad- 29sq ft New Pool Deck - 310 sq ft Existing Firepit - 13 sq ft Pool (at 50%) - 29 sq ft =149 sq ft Total Lot Coverage = 3,536sq ft = 49.1% Existing 4ft Black Aluminum Fence per safety Code Existing 4ftBlackAluminumFence per safetyCode 3' x 4' Pool equipment pad Remove existing paversand stack them off to theside to reuse. Also removeexisting bench anddispose of. 13'8' 9"22' 8"6' 3"Scale: 1/30" = 1 ft R 3'REQUIRED: (4) 3' LONG 8 GAUGE COPPER WIRE BONDING POINTS FROM POOL STEEL CONNECTED TOEQUIPOTENTIAL BONDING GRID4" - 6" DEEP AND 18" - 24" FROM WATERS EDGE. Bubbler Skimmer Side Suction Wall Return Main Drains Plumb Only for Cleaner Auto Fill Water /Hose Bib F Spa Fountain Line Spa Jets LED Pool Light Spa Lights Existing Gas Tank LEGEND G R 3' SJ RETURN LOOP PIPING 1.5" SCH 40 PVC FROM TRUNK PIPE TRUNK PIPING 2.5" SCH 40 PVC TO THE BRANCH PIPING 3.0" SCH 40 PVC BETWEEN MAIN DRAINS RETURN TRUNK PIPING 2.0" SCH 40 PVC FROM THE PUMP TO RETURN LOOPPIPE AROUND POOL Scale: 1/8" = 1 ft Name:SHABBY CHIC LLC (ANDREW COWN Address:1691 ATLANTIC BEACH DR City, State, Zip:ATLANTIC BEACH, FL 32233 CLIENT INFORMATION Size:12' X 24'Area:297SQ FT Pool Gallons:8,886 Depth:3' - 5'Perimeter:75 LN FT Spa Gallons: Plaster Type:CRYSTAL STONE NATURAL Plaster Color:ONYX POOL SPECIFICATIONS # of Returns:3 # of Skimmers:1 # of Pool Main Drains:2 FLOOR # of Spa Main Drain:N/A Cleaning System:PLUMB ONLY # of In-Floors:N/A # of Vac Lines:1 Type of Robot Vac:PRESSURE Water Features:BUBBLER Branch Piping:3.0 Trunk Piping:3 Return Piping:2.0 PLUMBING SPECIFICATIONS Pool Pump:PENTAIR INTELLIFLO VSF 2nd Pump:N/A Filteration Type:PENTAIR CLEAN & CLEAR Filter Size:200 SQ FT Heat Pump:N/A Heater:N/A Chlorinator:PENTAIR INTELLICHLOR Blower:N/A Pool Automation:N/A Computer Controls:INTELLICONNECT # of Pool Lights:1 LED (WITH NICHE)# of Spa Lights:N/A EQUIPMENT SPECICATIONS Tile Vendor:NOBLE Tile Product #:NEAG 636 Locations:POOL WATERLINE Spillways:N/A Glass Tile Vendor:N/A Glass Tile Location:N/A Spa Interior:NA Spa Exterior:N/A TILE SPECIFICATIONS Type of Paver:TREMRON Pool Deck Area:SQ FT Size of Pavers:REUSE EXISTINGPAVERS Paver Color:Reuse Existing Pavers Type of Coping:TREMRON Coping Perimeter:122 LN FT Size of Coping:4" X 9"Coping Color:SAND DUNE Footer:N/A Retaining Wall:NON STRUCTURAL TREMRONSTONEGATE BLOCK DECK SPECIFICATIONS Baby Barrier Screen Enclosure: Fence: x Pool/Spa Water Alarms: X SAFETY REQUIREMENTS PER SAFETY CODE Sales Team:KEVIN CARROLL & CHRIS MYERS Checked By:JASON WINTER Drawn By:CHRIS MYERS Date of Contract: Date of Drawings: Contractor & License #KEVIN J. CARROLL, CPC1458340 PAGE DOCUMENT INFORMATION 115 Solana Rd, Suite C Ponte Vedra Beach, FL 32082 Office 904-543-2626 - CPC 1458340 Scale: 1/8" : 1' PLUMBING PLAN Scale: 1/8" : 1' PLUMBING PLAN 6' 4"12'24' 3' 6'12' x 24' 297 sq ft 75 linear ft 8'10' 1"9'40 ft of deck drain 12' ft long Swimout, 18" deepStandard pool light Existing firepit to remain.19' 4"6' 4"5ft deep3ft deep 72 linear ft of Tremron Stonegate block 9'6'4' 9"Existing pavers to remain on lanai Firewater bowls with 30" x 30" columns raised 12" from ground level (same level as the pool deck) Bench Step StepSun shelf with umbrella & bubbler Existing 4ft Black Aluminum Fence per safety code Existing 4ft Black Aluminum Fence per safety Code7'7' x 10' Slat wall painted white 15' L-shape summer kitchen with green egg platform (egg by homeowner), fridge, kegerator and extended countertop bar 3' x 4' Pool equipment pad1' 8"10'1' 6"6' 9'9' 12' 3"12' 3" R 3'REQUIRED: (4) 3' LONG 8 GAUGE COPPER WIRE BONDING POINTS FROM POOL STEEL CONNECTED TO EQUIPOTENTIAL BONDING GRID 4" - 6" DEEP AND 18" - 24" FROM WATERS EDGE. Bubbler Skimmer Side Suction Wall Return Main Drains Plumb Only for Cleaner Auto Fill Water /Hose Bib F Spa Fountain Line Spa Jets LED Pool Light Spa Lights Existing Gas Tank LEGEND G R 3' SJ R R Remove existing pavers and stack them off to the side to reuse. Also remove existing bench and dispose of. Scale: 1/8" = 1 ft Name:SHABBY CHIC LLC (ANDREW COWN Address:1691 ATLANTIC BEACH DR City, State, Zip:ATLANTIC BEACH, FL 32233 CLIENT INFORMATION Size:12' X 24'Area:297SQ FT Pool Gallons:8,886 Depth:3' - 5'Perimeter:75 LN FT Spa Gallons: Plaster Type:CRYSTAL STONE NATURAL Plaster Color:ONYX POOL SPECIFICATIONS # of Returns:3 # of Skimmers:1 # of Pool Main Drains:2 FLOOR # of Spa Main Drain:N/A Cleaning System:PLUMB ONLY # of In-Floors:N/A # of Vac Lines:1 Type of Robot Vac:PRESSURE Water Features:BUBBLER Branch Piping:3.0 Trunk Piping:3 Return Piping:2.0 PLUMBING SPECIFICATIONS Pool Pump:PENTAIR INTELLIFLO VSF 2nd Pump:N/A Filteration Type:PENTAIR CLEAN & CLEAR Filter Size:200 SQ FT Heat Pump:N/A Heater:N/A Chlorinator:PENTAIR INTELLICHLOR Blower:N/A Pool Automation:N/A Computer Controls:INTELLICONNECT # of Pool Lights:1 LED (WITH NICHE)# of Spa Lights:N/A EQUIPMENT SPECICATIONS Tile Vendor:NOBLE Tile Product #:NEAG 636 Locations:POOL WATERLINE Spillways:N/A Glass Tile Vendor:N/A Glass Tile Location:N/A Spa Interior:NA Spa Exterior:N/A TILE SPECIFICATIONS Type of Paver:TREMRON Pool Deck Area:SQ FT Size of Pavers:REUSE EXISTINGPAVERS Paver Color:Reuse Existing Pavers Type of Coping:TREMRON Coping Perimeter:122 LN FT Size of Coping:4" X 9"Coping Color:SAND DUNE Footer:N/A Retaining Wall:NON STRUCTURAL TREMRONSTONEGATE BLOCK DECK SPECIFICATIONS Baby Barrier Screen Enclosure: Fence: x Pool/Spa Water Alarms: X SAFETY REQUIREMENTS PER SAFETY CODE Sales Team:KEVIN CARROLL & CHRIS MYERS Checked By:JASON WINTER Drawn By:CHRIS MYERS Date of Contract: Date of Drawings: Contractor & License #KEVIN J. CARROLL, CPC1458340 PAGE DOCUMENT INFORMATION 115 Solana Rd, Suite C Ponte Vedra Beach, FL 32082 Office 904-543-2626 - CPC 1458340 Construction Drawing Scale: 1/8" : 1' Construction Drawing Scale: 1/8" : 1' CPC1458340 www.coastalluxurypv.com 8/13/2021 115 Solana Rd, Suite C Ponte Vedra Beach, FL, 32082 Office 904-272-7946 Office 904-543-2626 Fax 866-609-2717 Customer Name: Address: City, State, Zip: Determine Maximum System Flow Rate Minimum Flow Rate Required: 35gpm per skimmer (required: 1 skimmer per 800 sq ft of surf. area) 1. Calculate Pool Volume x x 7.48 (gal./cubic foot)= (Surface Area) (Avg Depth)(Volume in Gallons) 2. Determine preferred Turnover Time in Hours: x 60 (Min/Hr) = 3. Determine Max Flow Rate /+= 4. Spa Jets:x GPM per jet =Flow Rate (For Single Pump pool/spa combo, use the higher of No. 3 or No. 4 in the following calculations for the pool & Spa) Determine Pipe Sizes: Branch Piping to be inch to keep velocity @ 6 fps max. at gpm Maximum System Flow Rate Return Piping to be inch to keep velocity @ 8 fps max. at gpm Maximum System Flow Rate Suction Piping to be inch to keep velocity @ 8 fps max. at gpm Maximum System Flow Rate 1. Distance from pool, to pump in Ft: 2. Friction loss (in suction pipe) in inch pipe per 1 t. @ gpm =(from pipe flow/friction loss chart) 3. Friction loss (in return pipe) in inch pipe per 1 t. @ gpm =(from pipe flow/friction loss chart) 4.x = (Length of Return Pipe) 5.x = (Length of Suction Pipe) Flow and Friction Loss Per Foot TDH in Piping Filter loss in TDH (from filter data sheet) Heater loss in TDH (from heater data sheet) Total all other loss Total Dynamic Head (TDH) Determine the Number and Type of Required In---floor Suction Outlets: (Check all that apply) 3 gpm max. flow (see note 2) gpm max. flow (see note 3) gpm w/ ports (see note 4) Filter Make/Size 70 0.08 5.6 2 suction outlets @ suction outlets @ 70 136 82 117 2" 62gpm 0.06' 82gpm .10' 2.5" 88gpm 0.05' 117gpm 3" 136gpm 0.04' 181gpm .07' .08' channel drains @ 144 (2) Star Guard 8" 19.6 Pipe Size 6 FPS 8 FPS Velocity - Feet Per Second 1.5" 37gpm 0.08' 50gpm .14' Shabby Chic Holdings, LLC 1691 Atlantic Beach Dr Atlantic Beach, FL 32233 70 2.5 0 15 0 (No of Jets) (Jet Flow)(Total Jet Flow Rate) 3 Simplified Total Dynamic Head (TDH) Calculation Worksheet 297 ANSI/APSPt 7, 2013 Specifies three methods for determining the maximum system flow rate. The following simplified TDH calculation is one of the methods specified. 6 360 (Hours)(Turnover in Min.) 8,886 360 12.6 4 8886.24 (Volume in Gallons)(Turnover in Min.) (Auxiliary Flow Rate) (System Flow Rate) 2 0.08 0.1 Determine Simplified TDH: 2.5 (Ft of head/1 ft of Pipe)(TDH Suction Pipe) (Schedule 40 pvc Pipe) 0.1 (Ft of head/1 ft of Pipe) 7 (TDH Return Pipe) 2 0 24.684 7 CPC1458340 www.coastalluxurypv.com 8/13/2021 115 Solana Rd, Suite C Ponte Vedra Beach, FL, 32082 Office 904-272-7946 Office 904-543-2626 Fax 866-609-2717 Pool Water Volume ÷ 360 =gpm = filtration flow rate Is there an Auxiliary load on the filtration pump? Yes If so, what is the auxiliary flow rate gpm Maximum Flow Rate gpm (maximum auxiliary pool loads or the filtration flow rate, whichever is greater. The pool filtration flow rate shall not be greater than the rate needed to turn over the pool water volume in 6 hours or 36 gpm whichever is greater. This means that for pools of less than 13000 gallons, the pump shall be sized to have a flow rate of 36 gpm or less. Suction Pipe size @ 6 fps inch Return Pipe size @ 8 FPS inch Filter Factors: (Cartridge .375) or (D.E 2) or (Sand 15) ÷ = (flow rate) (filter factor) (minimum filter size) Filter Make/Size Backwash valve? Yes No X (if yes, must be 2 inch min) Pump Selection from APSP database on Curve A (less than 17000 gallons) or C (greater than 17000 gallons) (circle one) Model Flow Rate (low speed)gpm@ rpm Flow Rate (high speed) gpm@ rpm (not required if no auxiliary load on filtration pump) Pump Controls: Standard time clock / 2 speed time clock or other Heater Model: Note: Suction Piping in Front of Pump Inlet Must Be 4 pipe diameters in length. Must have 18" of straight pipe after the filter for Solar. Swimming Pool Specifications for: Owner: Shabby Chic Holdings, LLC Address: 1691 Atlantic Beach Dr City, State, Zip: Atlantic Beach, FL 32233 904-548-2626 Telephone Number Certification Number Print Name Contractors Signature 6" 534gpm 0.02' 712gpm .03' CPC 1458340 Kevin J. Carroll Date 0.03' 313gpm .05' 117gpm .08' 3" 136gpm 0.04' 181gpm .07' 2.5" 88gpm 0.05' 4" 234gpm 2.5 2 24.684 0.375 65.824 Pentair Cllean & Clear Cartridge 200 Pentair Intelliflo VSF - Variable and be embossed with that edition approval None 2" 62gpm 0.06' 82gpm .10' 3450 62513.3 Variable Speed Pump 6 FPS 8 FPS 6. Pump, Filter and Heater make and model cannot change, and equipment location cannot be move closer to the pool without submitting a revised plan and TDH calculation worksheet for approval 72.5 Velocity - Feet Per Second 37gpm 0.08' 50gpm .14'1.5" Pipe Size 4. See installation instructions for number of ports to be used 5. In---Floor suction outlet cover/grate must conform to most recent edition of ASME/ANSI A112.19.8 ☐ Maximum Flow Capacity of the new or replacement pump Notes: 1. If a variable speed pump is used, use the max pump flow in calculations 2. For side wall drains, use appropriate side wall drain flow as published by manufacturer 3. Insert manufacturer’s name and approved maximum flow TDH Calculation Options (For each Pump) Check one ☐ Simplified Total Dynamic Head (STDH) Complete STDH Worksheet – Fill in all blanks ☐ Total Dynamic Head (TDH) Complete Program or other calcs. Fill in required blanks on worksheet & attach calculations ANSI/APSP/ICC Worksheet Swimming Pool Energy Efficiency Compliance Information Note: These Requirements Apply ONLY to the Filtration Pump  Maximum Filtration Flow Rate Calcutlations 8886.24 NO 24.684 0 24.684 CPC1458340 www.coastalluxurypv.com 8/13/2021 115 Solana Rd, Suite C Ponte Vedra Beach, FL, 32082 Office 904-272-7946 Office 904-543-2626 Fax 866-609-2717 P S I 94.4 96.6 98.983.1 85.4 85.3 87.6 87.6 89.9 89.8 92.2 92.1 94.4 96.7 98.9 101.2 92 94.3 33 76.2 78.5 80.7 83 85.3 87.5 89.8 92 94.3 96.6 32 73.9 76.2 78.4 80.7 83.1 85.2 87.5 89.7 87.4 89.6 31 71.6 73.9 76.1 78.4 80.7 82.9 85.2 87.4 89.7 92 30 69.3 71.6 73.8 76.1 78.3 80.6 82.9 85.1 85 29 67 69.3 71.5 73.8 78.3 80.5 82.8 85.1 87.3 28 64.7 66.9 69.2 71.5 76 78.2 80.5 82.873.7 76 80.4 27 62.4 64.6 66.9 69.2 73.7 75.9 78.2 90.5 82.7 26 60.1 62.3 64.6 66.8 71.4 73.6 75.9 78.169.1 71.4 25 57.8 60 62.3 64.5 69.1 73.6 75.8 7866.8 69 71.2 73.5 24 55.4 57.7 60 62.5 66.7 71.3 73.5 75.864.5 55.2 22 50.8 53.1 55.3 57.6 23 53.1 55.4 57.7 59.9 20 21 48.5 46.2 48.5 50.8 53 53 55.3 57.6 59.9 62.2 18 19 41.6 43.9 43.8 46.2 48.4 50.7 50.6 52.9 43.6 16 17 37 39.3 39.2 41.5 43.7 46.1 46 48.3 14 15 34.6 34.6 36.9 39.1 41.4 41.4 43.7 45.9 48.3 50.6 12 13 30 32.3 34.5 36.8 36.8 39.1 39 41.3 10 11 25.4 27.7 29.9 32.2 32.1 34.5 34.4 36.7 8 9 20.7 23.1 25.3 27.6 27.5 29.8 29.8 32.1 6 7 16.1 18.4 29.7 31.9 34.2 32 34.3 36.5 20.6 23 5 11.5 13.8 25.1 27.3 29.6 27.4 29.6 31.918.3 3 9.2 20.4 22.7 25 22.8 25 27.3 4 13.7 16 0 1 2 6 6.8 9.1 11.4 78.5 80.9 2 2.3 4.6 6.9 34 35 0 2.3 0 4.6 6.9 9.2 11.5 13.9 16.2 18.5 20.8 23.1 25.4 27.7 30 32.3 80.8 83.1 4 4.5 5.8 6.1 11.5 13.8 16.1 18.4 20.7 23 25.3 27.6 29.9 32.2 34.5 36.9 39.2 41.5 43.8 46.1 48.4 50.7 8 9 11.4 13.7 16 18.3 20.6 22.9 25.2 10 11.3 13.6 15.9 18.2 20.5 22.8 25.2 27.5 52.9 55.2 57.5 59.8 62.1 64.4 12 13.6 15.9 18.2 20.5 22.8 25.1 27.4 29.7 32 34.3 36.7 39 41.3 43.6 45.9 48.2 50.5 52.8 55.1 57.4 59.8 62.1 64.4 66.7 69 71.3 14 16 18 15.8 18.1 20.3 18.1 20.4 22.7 34.4 36.6 38.8 36.6 38.9 41.1 38.9 41.2 43.4 50.5 52.7 55 52.8 55 57.3 41.2 43.5 45.8 43.5 45.8 48.1 45.9 48.1 50.4 * NOTE: FIELD TDH MUST BE EQUAL TO OR HIGHER THAN THE CALCULATED TDH. ** GAGES TO BE INSTALLED AT THE TIME OF FINAL INSPECTION FOR VERIFICATION. Total Head In Feet Conversion Chart Inches Mercury (Vacuum Gauge) 62 64.3 66.5 64.3 66.6 58.9 66.6 68.9 71.2 55.1 57.4 59.6 57.4 59.7 61.9 59.7 62 64.2 48.2 50.4 52.7 6' 4"12'24' 3' 6'12' x 24' 297 sq ft 75 linear ft 8'10' 1"9'40 ft of deck drain 12' ft long Swimout, 18" deepStandard pool light Existing firepit to remain.19' 4"6' 4"5ft deep3ft deep 72 linear ft of Tremron Stonegate block 9'6'4' 9"Existing pavers to remain on lanai Firewater bowls with 30" x 30" columns raised 12" from ground level (same level as the pool deck) Bench Step StepSun shelf with umbrella & bubbler Existing 4ft Black Aluminum Fence per safety code Existing 4ft Black Aluminum Fence per safety Code7'7' x 10' Slat wall painted white 15' L-shape summer kitchen with green egg platform (egg by homeowner), fridge, kegerator and extended countertop bar 3' x 4' Pool equipment pad1' 8"10'1' 6"6' 9'9' 12' 3"12' 3" R 3'REQUIRED: (4) 3' LONG 8 GAUGE COPPER WIRE BONDING POINTS FROM POOL STEEL CONNECTED TO EQUIPOTENTIAL BONDING GRID 4" - 6" DEEP AND 18" - 24" FROM WATERS EDGE. Bubbler Skimmer Side Suction Wall Return Main Drains Plumb Only for Cleaner Auto Fill Water /Hose Bib F Spa Fountain Line Spa Jets LED Pool Light Spa Lights Existing Gas Tank LEGEND G R 3' SJ R R Remove existing pavers and stack them off to the side to reuse. Also remove existing bench and dispose of. Scale: 1/8" = 1 ft Name:SHABBY CHIC LLC (ANDREW COWN Address:1691 ATLANTIC BEACH DR City, State, Zip:ATLANTIC BEACH, FL 32233 CLIENT INFORMATION Size:12' X 24'Area:297SQ FT Pool Gallons:8,886 Depth:3' - 5'Perimeter:75 LN FT Spa Gallons: Plaster Type:CRYSTAL STONE NATURAL Plaster Color:ONYX POOL SPECIFICATIONS # of Returns:3 # of Skimmers:1 # of Pool Main Drains:2 FLOOR # of Spa Main Drain:N/A Cleaning System:PLUMB ONLY # of In-Floors:N/A # of Vac Lines:1 Type of Robot Vac:PRESSURE Water Features:BUBBLER Branch Piping:3.0 Trunk Piping:3 Return Piping:2.0 PLUMBING SPECIFICATIONS Pool Pump:PENTAIR INTELLIFLO VSF 2nd Pump:N/A Filteration Type:PENTAIR CLEAN & CLEAR Filter Size:200 SQ FT Heat Pump:N/A Heater:N/A Chlorinator:PENTAIR INTELLICHLOR Blower:N/A Pool Automation:N/A Computer Controls:INTELLICONNECT # of Pool Lights:1 LED (WITH NICHE)# of Spa Lights:N/A EQUIPMENT SPECICATIONS Tile Vendor:NOBLE Tile Product #:NEAG 636 Locations:POOL WATERLINE Spillways:N/A Glass Tile Vendor:N/A Glass Tile Location:N/A Spa Interior:NA Spa Exterior:N/A TILE SPECIFICATIONS Type of Paver:TREMRON Pool Deck Area:SQ FT Size of Pavers:REUSE EXISTINGPAVERS Paver Color:Reuse Existing Pavers Type of Coping:TREMRON Coping Perimeter:122 LN FT Size of Coping:4" X 9"Coping Color:SAND DUNE Footer:N/A Retaining Wall:NON STRUCTURAL TREMRONSTONEGATE BLOCK DECK SPECIFICATIONS Baby Barrier Screen Enclosure: Fence: x Pool/Spa Water Alarms: X SAFETY REQUIREMENTS PER SAFETY CODE Sales Team:KEVIN CARROLL & CHRIS MYERS Checked By:JASON WINTER Drawn By:CHRIS MYERS Date of Contract: Date of Drawings: Contractor & License #KEVIN J. CARROLL, CPC1458340 PAGE DOCUMENT INFORMATION 115 Solana Rd, Suite C Ponte Vedra Beach, FL 32082 Office 904-543-2626 - CPC 1458340 Construction Drawing Scale: 1/8" : 1' Construction Drawing Scale: 1/8" : 1' DESCRIPTION ACCOUNT QTY PAID PermitTRAK $515.19 POOL21-0032 Address: 1691 ATLANTIC BEACH DR APN: 169505 1375 $515.19 BUILDING $205.00 BUILDING PERMIT 455-0000-322-1000 0 $205.00 BUILDING PLAN REVIEW $102.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $102.50 PUBLIC WORKS PLAN REVIEW $100.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE SURCHARGES $7.69 STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.61 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.08 ZONING PLAN REVIEW $100.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL FEES PAID BY RECEIPT: R16883 $515.19 Printed: Thursday, August 26, 2021 5:01 PM Date Paid: Thursday, August 26, 2021 Paid By: Chris Myers Pay Method: CREDIT CARD 503199238 1 of 1 Cashier: JJ Cash Register Receipt City of Atlantic Beach Receipt Number R16883