1691 Atlantic Beach Dr POOL21-0032 pool permitOWNER:ADDRESS:CITY:STATE:ZIP:
SHABBY CHIC HOLDINGS
LLC 3948 3rd ST JACKSONVILLE
BEACH FL 32250
COMPANY:ADDRESS:CITY:STATE:ZIP:
COASTAL LUXURY
OUTDOORS LLC 115 Solana Rd Suite C PONTE VEDRA
BEACH FL 32082
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169505 1375 ATLANTIC BEACH
COUNTRY CLUB UNIT 02
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1691 ATLANTIC BEACH DR SWIMMING POOL SWIMMING
POOL RESIDENTIAL SWIMMING POOL $30000.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247-
5814) to request an Erosion and Sediment Control Inspection prior to start of construction.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN
YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 8/27/2021
PERMIT NUMBER
POOL21-0032
ISSUED: 8/27/2021
EXPIRES: 2/23/2022
SWIMMING POOL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $205.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $102.50
PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.61
STATE DCA SURCHARGE 455-0000-208-0600 0 $3.08
ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00
TOTAL: $515.19
2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
3 PUBLIC WORKS POOL WELLPOINT INFORMATIONAL
Notes:
Pool Wellpoint (if used) must discharge into vegetated area 10 foot minimum from street or drainage feature (swale, structure or lagoon).
4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
6 PUBLIC WORKS RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site. Cannot raise lot elevation.
7 PUBLIC WORKS DECKING REMOVED INFORMATIONAL
Notes:
All old decking and debris must be removed from job site by Contractor.
8 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
2 of 2Issued Date: 8/27/2021
PERMIT NUMBER
POOL21-0032
ISSUED: 8/27/2021
EXPIRES: 2/23/2022
SWIMMING POOL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
POOL21-0032
POOL21-0032
Project Name: Shabby Chic Holdings, LLC Date: 8-13-2021
Address: 1691 Atlantic Beach Dr
Atlantic Beach, FL 32233
Construction: Inground concrete swimming pool
Occupancy Class: Single Family Dwelling Group R-3
Existing Lot Coverage:
Lot Square Footage: 7,200 sq ft
House: 2,587sq ft
Driveway & front walk: 448 sq ft
AC pad and Wall: 17 sq ft
Existing Paver Patio with Firepit: 838
Total Lot Coverage: 3,873 sq ft
Percentage: 53.8%
Revised Lot Coverage
Lot Square Footage: 7,200 sq ft
House: 2,587sq ft
Driveway & front walk: 448 sq ft
Remove Existing Paver: -838 sq ft
AC Pad, Pool Equipment Pad and Wall: 29 sq ft
Existing Fire Pit: 13 sq ft
New Paver Deck: 310 sq ft
New Pool: 297 sq ft = 149 sq ft @ 50%
Total Coverage: 3,536
Percentage: 49.1%
Index:
Cover Letter
Notice of Commencement
Agent Ltr
Permit Application
Tree Removal Affidavit
Coastal Luxury Outdoors 115 Solana Rd, Suite
Ponte Vedra Beach, FL 32082
Office (904) 543-2626 Fax (866) 609-2717
CPC 1458340
POOL21-0032
Proposed Topo Survey
Proposed Topo Survey with Pool
Permit Construction Drawing
Permit Plumbing Drawing
Engineered Drawings
TDH
Data Sheets
Lot Coverage
Lot - 7,180
House - 2587 sq ft
Driveway & Front walkway - 448 sq ft
A/C Pad & Wall - 17 sq ft
Existing Paver Patio - 838 sq ft
Total Lot Coverage = 3,892 = 53.8%
Revised Lot Coverage
Lot - 7,200
House - 2587 sq ft
Driveway & Front walkway - 448 sq ft
Remove Existing Paver Patio - 838 sq ft
A/C Pad & Wall and pool equipment pad- 29sq ft
New Pool Deck - 310 sq ft
Existing Firepit - 13 sq ft
Pool (at 50%) - 29 sq ft =149 sq ft
Total Lot Coverage = 3,536sq ft = 49.1%
Existing 4ft
Black
Aluminum
Fence per safety
Code
Existing 4ftBlackAluminumFence per safetyCode
3' x 4' Pool
equipment pad
Remove existing paversand stack them off to theside to reuse. Also removeexisting bench anddispose of.
13'8' 9"22' 8"6' 3"Scale: 1/30" = 1 ft
R 3'REQUIRED:
(4) 3' LONG 8 GAUGE COPPER WIRE
BONDING POINTS FROM POOL
STEEL CONNECTED TOEQUIPOTENTIAL BONDING GRID4" - 6" DEEP AND 18" - 24" FROM
WATERS EDGE.
Bubbler
Skimmer
Side Suction
Wall Return
Main Drains
Plumb Only for Cleaner
Auto Fill
Water /Hose Bib
F Spa Fountain Line
Spa Jets
LED Pool Light
Spa Lights
Existing Gas Tank
LEGEND
G
R
3'
SJ
RETURN LOOP PIPING
1.5" SCH 40 PVC FROM
TRUNK PIPE
TRUNK PIPING 2.5"
SCH 40 PVC TO THE
BRANCH PIPING 3.0"
SCH 40 PVC BETWEEN
MAIN DRAINS
RETURN TRUNK
PIPING 2.0" SCH 40
PVC FROM THE PUMP
TO RETURN LOOPPIPE AROUND POOL
Scale: 1/8" = 1 ft
Name:SHABBY CHIC LLC (ANDREW COWN
Address:1691 ATLANTIC BEACH DR
City, State, Zip:ATLANTIC BEACH, FL 32233
CLIENT INFORMATION
Size:12' X 24'Area:297SQ FT Pool Gallons:8,886
Depth:3' - 5'Perimeter:75 LN FT Spa Gallons:
Plaster Type:CRYSTAL STONE NATURAL Plaster Color:ONYX
POOL SPECIFICATIONS
# of Returns:3 # of Skimmers:1
# of Pool Main Drains:2 FLOOR # of Spa Main Drain:N/A
Cleaning System:PLUMB ONLY # of In-Floors:N/A
# of Vac Lines:1 Type of Robot Vac:PRESSURE
Water Features:BUBBLER Branch Piping:3.0
Trunk Piping:3 Return Piping:2.0
PLUMBING SPECIFICATIONS
Pool Pump:PENTAIR INTELLIFLO VSF 2nd Pump:N/A
Filteration Type:PENTAIR CLEAN & CLEAR Filter Size:200 SQ FT
Heat Pump:N/A Heater:N/A
Chlorinator:PENTAIR INTELLICHLOR Blower:N/A
Pool Automation:N/A Computer Controls:INTELLICONNECT
# of Pool Lights:1 LED (WITH NICHE)# of Spa Lights:N/A
EQUIPMENT SPECICATIONS
Tile Vendor:NOBLE Tile Product #:NEAG 636
Locations:POOL WATERLINE Spillways:N/A
Glass Tile Vendor:N/A Glass Tile Location:N/A
Spa Interior:NA Spa Exterior:N/A
TILE SPECIFICATIONS
Type of Paver:TREMRON Pool Deck Area:SQ FT
Size of Pavers:REUSE EXISTINGPAVERS
Paver Color:Reuse Existing Pavers
Type of Coping:TREMRON Coping Perimeter:122 LN FT
Size of Coping:4" X 9"Coping Color:SAND DUNE
Footer:N/A Retaining Wall:NON STRUCTURAL TREMRONSTONEGATE BLOCK
DECK SPECIFICATIONS
Baby Barrier Screen Enclosure:
Fence: x Pool/Spa Water Alarms: X
SAFETY REQUIREMENTS PER SAFETY CODE
Sales Team:KEVIN CARROLL & CHRIS MYERS
Checked By:JASON WINTER
Drawn By:CHRIS MYERS
Date of Contract:
Date of Drawings:
Contractor & License #KEVIN J. CARROLL, CPC1458340
PAGE DOCUMENT INFORMATION
115 Solana Rd, Suite C
Ponte Vedra Beach, FL 32082
Office 904-543-2626 - CPC 1458340
Scale: 1/8" : 1'
PLUMBING PLAN
Scale: 1/8" : 1'
PLUMBING PLAN
6' 4"12'24'
3'
6'12' x 24'
297 sq ft
75 linear ft 8'10' 1"9'40 ft of deck
drain 12' ft long Swimout, 18" deepStandard pool
light
Existing firepit
to remain.19' 4"6' 4"5ft deep3ft deep
72 linear ft of
Tremron
Stonegate block
9'6'4' 9"Existing pavers
to remain on
lanai
Firewater bowls with 30" x 30"
columns raised 12" from ground
level (same level as the pool
deck)
Bench
Step StepSun shelf with
umbrella
& bubbler
Existing 4ft Black
Aluminum Fence
per safety code
Existing 4ft
Black
Aluminum
Fence per safety
Code7'7' x 10' Slat wall
painted white
15' L-shape summer
kitchen with green
egg platform (egg by
homeowner), fridge,
kegerator and
extended countertop
bar
3' x 4' Pool
equipment pad1' 8"10'1' 6"6'
9'9'
12' 3"12' 3"
R 3'REQUIRED:
(4) 3' LONG 8 GAUGE COPPER WIRE
BONDING POINTS FROM POOL
STEEL CONNECTED TO
EQUIPOTENTIAL BONDING GRID
4" - 6" DEEP AND 18" - 24" FROM
WATERS EDGE.
Bubbler
Skimmer
Side Suction
Wall Return
Main Drains
Plumb Only for Cleaner
Auto Fill
Water /Hose Bib
F Spa Fountain Line
Spa Jets
LED Pool Light
Spa Lights
Existing Gas Tank
LEGEND
G
R
3'
SJ
R
R
Remove existing pavers
and stack them off to the
side to reuse. Also remove
existing bench and dispose
of.
Scale: 1/8" = 1 ft
Name:SHABBY CHIC LLC (ANDREW COWN
Address:1691 ATLANTIC BEACH DR
City, State, Zip:ATLANTIC BEACH, FL 32233
CLIENT INFORMATION
Size:12' X 24'Area:297SQ FT Pool Gallons:8,886
Depth:3' - 5'Perimeter:75 LN FT Spa Gallons:
Plaster Type:CRYSTAL STONE NATURAL Plaster Color:ONYX
POOL SPECIFICATIONS
# of Returns:3 # of Skimmers:1
# of Pool Main Drains:2 FLOOR # of Spa Main Drain:N/A
Cleaning System:PLUMB ONLY # of In-Floors:N/A
# of Vac Lines:1 Type of Robot Vac:PRESSURE
Water Features:BUBBLER Branch Piping:3.0
Trunk Piping:3 Return Piping:2.0
PLUMBING SPECIFICATIONS
Pool Pump:PENTAIR INTELLIFLO VSF 2nd Pump:N/A
Filteration Type:PENTAIR CLEAN & CLEAR Filter Size:200 SQ FT
Heat Pump:N/A Heater:N/A
Chlorinator:PENTAIR INTELLICHLOR Blower:N/A
Pool Automation:N/A Computer Controls:INTELLICONNECT
# of Pool Lights:1 LED (WITH NICHE)# of Spa Lights:N/A
EQUIPMENT SPECICATIONS
Tile Vendor:NOBLE Tile Product #:NEAG 636
Locations:POOL WATERLINE Spillways:N/A
Glass Tile Vendor:N/A Glass Tile Location:N/A
Spa Interior:NA Spa Exterior:N/A
TILE SPECIFICATIONS
Type of Paver:TREMRON Pool Deck Area:SQ FT
Size of Pavers:REUSE EXISTINGPAVERS
Paver Color:Reuse Existing Pavers
Type of Coping:TREMRON Coping Perimeter:122 LN FT
Size of Coping:4" X 9"Coping Color:SAND DUNE
Footer:N/A Retaining Wall:NON STRUCTURAL TREMRONSTONEGATE BLOCK
DECK SPECIFICATIONS
Baby Barrier Screen Enclosure:
Fence: x Pool/Spa Water Alarms: X
SAFETY REQUIREMENTS PER SAFETY CODE
Sales Team:KEVIN CARROLL & CHRIS MYERS
Checked By:JASON WINTER
Drawn By:CHRIS MYERS
Date of Contract:
Date of Drawings:
Contractor & License #KEVIN J. CARROLL, CPC1458340
PAGE DOCUMENT INFORMATION
115 Solana Rd, Suite C
Ponte Vedra Beach, FL 32082
Office 904-543-2626 - CPC 1458340
Construction Drawing
Scale: 1/8" : 1'
Construction Drawing
Scale: 1/8" : 1'
CPC1458340
www.coastalluxurypv.com
8/13/2021
115 Solana Rd, Suite C
Ponte Vedra Beach, FL, 32082
Office 904-272-7946
Office 904-543-2626
Fax 866-609-2717
Customer Name:
Address:
City, State, Zip:
Determine Maximum System Flow Rate
Minimum Flow Rate Required: 35gpm per skimmer (required: 1 skimmer per 800 sq ft of surf. area)
1. Calculate Pool Volume x x 7.48 (gal./cubic foot)=
(Surface Area) (Avg Depth)(Volume in Gallons)
2. Determine preferred Turnover Time in Hours: x 60 (Min/Hr) =
3. Determine Max Flow Rate /+=
4. Spa Jets:x GPM per jet =Flow Rate
(For Single Pump pool/spa combo, use the higher of No. 3 or No. 4 in the following calculations for the pool & Spa)
Determine Pipe Sizes:
Branch Piping to be inch to keep velocity @ 6 fps max. at gpm Maximum System Flow Rate
Return Piping to be inch to keep velocity @ 8 fps max. at gpm Maximum System Flow Rate
Suction Piping to be inch to keep velocity @ 8 fps max. at gpm Maximum System Flow Rate
1. Distance from pool, to pump in Ft:
2. Friction loss (in suction pipe) in inch pipe per 1 t. @ gpm =(from pipe flow/friction loss chart)
3. Friction loss (in return pipe) in inch pipe per 1 t. @ gpm =(from pipe flow/friction loss chart)
4.x =
(Length of Return Pipe)
5.x =
(Length of Suction Pipe)
Flow and Friction Loss Per Foot
TDH in Piping
Filter loss in TDH (from filter data sheet)
Heater loss in TDH (from heater data sheet)
Total all other loss
Total Dynamic Head (TDH)
Determine the Number and Type of Required In---floor Suction Outlets:
(Check all that apply)
3 gpm max. flow (see note 2)
gpm max. flow (see note 3)
gpm w/ ports (see note 4)
Filter Make/Size
70 0.08 5.6
2 suction outlets @
suction outlets @
70
136
82
117
2" 62gpm 0.06' 82gpm .10'
2.5" 88gpm 0.05' 117gpm
3" 136gpm 0.04' 181gpm .07'
.08'
channel drains @
144
(2) Star Guard 8"
19.6
Pipe Size 6 FPS 8 FPS
Velocity - Feet Per Second
1.5" 37gpm 0.08' 50gpm .14'
Shabby Chic Holdings, LLC
1691 Atlantic Beach Dr
Atlantic Beach, FL 32233
70
2.5
0 15 0
(No of Jets) (Jet Flow)(Total Jet Flow Rate)
3
Simplified Total Dynamic Head (TDH) Calculation Worksheet
297
ANSI/APSPt 7, 2013 Specifies three methods for determining the maximum system flow rate. The following simplified TDH
calculation is one of the methods specified.
6 360
(Hours)(Turnover in Min.)
8,886 360
12.6
4 8886.24
(Volume in Gallons)(Turnover in Min.) (Auxiliary Flow Rate) (System Flow Rate)
2
0.08
0.1
Determine Simplified TDH:
2.5
(Ft of head/1 ft of Pipe)(TDH Suction Pipe)
(Schedule 40 pvc Pipe)
0.1
(Ft of head/1 ft of Pipe)
7
(TDH Return Pipe)
2
0 24.684
7
CPC1458340
www.coastalluxurypv.com
8/13/2021
115 Solana Rd, Suite C
Ponte Vedra Beach, FL, 32082
Office 904-272-7946
Office 904-543-2626
Fax 866-609-2717
Pool Water Volume ÷ 360 =gpm = filtration flow rate
Is there an Auxiliary load on the filtration pump? Yes
If so, what is the auxiliary flow rate gpm
Maximum Flow Rate gpm (maximum auxiliary pool loads or
the filtration flow rate, whichever is greater.
The pool filtration flow rate shall not be greater than the rate needed
to turn over the pool water volume in 6 hours or 36 gpm whichever is
greater. This means that for pools of less than 13000 gallons, the pump
shall be sized to have a flow rate of 36 gpm or less.
Suction Pipe size @ 6 fps inch
Return Pipe size @ 8 FPS inch
Filter Factors: (Cartridge .375) or (D.E 2) or (Sand 15)
÷ =
(flow rate) (filter factor) (minimum filter size)
Filter Make/Size
Backwash valve? Yes No X (if yes, must be 2 inch min)
Pump Selection from APSP database on Curve A (less than 17000
gallons) or C (greater than 17000 gallons) (circle one)
Model
Flow Rate (low speed)gpm@ rpm
Flow Rate (high speed) gpm@ rpm
(not required if no auxiliary load on filtration pump)
Pump Controls:
Standard time clock / 2 speed time clock or other
Heater Model:
Note: Suction Piping in Front of Pump Inlet Must Be 4 pipe diameters in length.
Must have 18" of straight pipe after the filter for Solar.
Swimming Pool Specifications for:
Owner: Shabby Chic Holdings, LLC
Address: 1691 Atlantic Beach Dr
City, State, Zip: Atlantic Beach, FL 32233
904-548-2626
Telephone Number
Certification Number
Print Name
Contractors Signature
6" 534gpm 0.02' 712gpm .03'
CPC 1458340
Kevin J. Carroll
Date
0.03' 313gpm .05'
117gpm .08'
3" 136gpm 0.04' 181gpm .07'
2.5" 88gpm 0.05'
4" 234gpm
2.5
2
24.684 0.375 65.824
Pentair Cllean & Clear Cartridge 200
Pentair Intelliflo VSF - Variable and be embossed with that edition approval
None
2" 62gpm 0.06' 82gpm .10'
3450
62513.3
Variable Speed Pump
6 FPS 8 FPS
6. Pump, Filter and Heater make and model cannot
change, and equipment location cannot be move
closer to the pool without submitting a revised plan
and TDH calculation worksheet for approval
72.5
Velocity - Feet Per Second
37gpm 0.08' 50gpm .14'1.5"
Pipe Size
4. See installation instructions for number of ports
to be used
5. In---Floor suction outlet cover/grate must conform
to most recent edition of ASME/ANSI A112.19.8
☐ Maximum Flow Capacity
of the new or replacement pump
Notes:
1. If a variable speed pump is used, use the max pump
flow in calculations
2. For side wall drains, use appropriate side wall drain
flow as published by manufacturer
3. Insert manufacturer’s name and approved
maximum flow
TDH Calculation Options
(For each Pump)
Check one
☐ Simplified Total Dynamic Head (STDH)
Complete STDH Worksheet – Fill in all blanks
☐ Total Dynamic Head (TDH)
Complete Program or other calcs. Fill in required
blanks on worksheet & attach calculations
ANSI/APSP/ICC Worksheet
Swimming Pool Energy Efficiency Compliance Information
Note: These Requirements Apply ONLY to the Filtration Pump
Maximum Filtration Flow Rate Calcutlations
8886.24
NO
24.684
0
24.684
CPC1458340
www.coastalluxurypv.com
8/13/2021
115 Solana Rd, Suite C
Ponte Vedra Beach, FL, 32082
Office 904-272-7946
Office 904-543-2626
Fax 866-609-2717
P
S
I
94.4 96.6 98.983.1
85.4
85.3
87.6
87.6
89.9
89.8
92.2
92.1
94.4 96.7 98.9 101.2
92 94.3
33 76.2 78.5 80.7 83 85.3 87.5 89.8 92 94.3 96.6
32 73.9 76.2 78.4 80.7 83.1 85.2 87.5 89.7
87.4 89.6
31 71.6 73.9 76.1 78.4 80.7 82.9 85.2 87.4 89.7 92
30 69.3 71.6 73.8 76.1 78.3 80.6 82.9 85.1
85
29 67 69.3 71.5 73.8 78.3 80.5 82.8 85.1 87.3
28 64.7 66.9 69.2 71.5 76 78.2 80.5 82.873.7
76
80.4
27 62.4 64.6 66.9 69.2 73.7 75.9 78.2 90.5 82.7
26 60.1 62.3 64.6 66.8 71.4 73.6 75.9 78.169.1
71.4
25 57.8 60 62.3 64.5 69.1 73.6 75.8 7866.8
69 71.2 73.5
24 55.4 57.7 60 62.5 66.7 71.3 73.5 75.864.5
55.2
22 50.8 53.1 55.3 57.6
23 53.1 55.4 57.7 59.9
20
21 48.5
46.2 48.5
50.8 53
53
55.3 57.6
59.9
62.2
18
19
41.6
43.9
43.8
46.2
48.4
50.7
50.6
52.9
43.6
16
17
37
39.3
39.2
41.5
43.7
46.1
46
48.3
14
15 34.6
34.6
36.9
39.1
41.4
41.4
43.7 45.9
48.3
50.6
12
13
30
32.3
34.5
36.8
36.8
39.1
39
41.3
10
11
25.4
27.7
29.9
32.2
32.1
34.5
34.4
36.7
8
9
20.7
23.1
25.3
27.6
27.5
29.8
29.8
32.1
6
7
16.1
18.4
29.7 31.9 34.2
32 34.3 36.5
20.6
23
5
11.5
13.8
25.1 27.3 29.6
27.4 29.6 31.918.3
3 9.2
20.4 22.7 25
22.8 25 27.3
4
13.7
16
0
1
2
6
6.8
9.1
11.4
78.5
80.9
2
2.3
4.6
6.9
34
35
0
2.3
0
4.6
6.9
9.2
11.5
13.9
16.2
18.5
20.8
23.1
25.4
27.7
30
32.3
80.8
83.1
4
4.5
5.8
6.1
11.5
13.8
16.1
18.4
20.7
23
25.3
27.6
29.9
32.2
34.5
36.9
39.2
41.5
43.8
46.1
48.4
50.7
8
9
11.4
13.7
16
18.3
20.6
22.9
25.2
10
11.3
13.6
15.9
18.2
20.5
22.8
25.2
27.5
52.9
55.2
57.5
59.8
62.1
64.4
12
13.6
15.9
18.2
20.5
22.8
25.1
27.4
29.7
32
34.3
36.7
39
41.3
43.6
45.9
48.2
50.5
52.8
55.1
57.4
59.8
62.1
64.4
66.7
69
71.3
14 16 18
15.8 18.1 20.3
18.1 20.4 22.7
34.4 36.6 38.8
36.6 38.9 41.1
38.9 41.2 43.4
50.5 52.7 55
52.8 55 57.3
41.2 43.5 45.8
43.5 45.8 48.1
45.9 48.1 50.4
* NOTE: FIELD TDH MUST BE EQUAL TO OR HIGHER THAN THE
CALCULATED TDH.
** GAGES TO BE INSTALLED AT THE TIME OF FINAL INSPECTION FOR
VERIFICATION.
Total Head In Feet Conversion Chart
Inches Mercury (Vacuum Gauge)
62 64.3 66.5
64.3 66.6 58.9
66.6 68.9 71.2
55.1 57.4 59.6
57.4 59.7 61.9
59.7 62 64.2
48.2 50.4 52.7
6' 4"12'24'
3'
6'12' x 24'
297 sq ft
75 linear ft 8'10' 1"9'40 ft of deck
drain 12' ft long Swimout, 18" deepStandard pool
light
Existing firepit
to remain.19' 4"6' 4"5ft deep3ft deep
72 linear ft of
Tremron
Stonegate block
9'6'4' 9"Existing pavers
to remain on
lanai
Firewater bowls with 30" x 30"
columns raised 12" from ground
level (same level as the pool
deck)
Bench
Step StepSun shelf with
umbrella
& bubbler
Existing 4ft Black
Aluminum Fence
per safety code
Existing 4ft
Black
Aluminum
Fence per safety
Code7'7' x 10' Slat wall
painted white
15' L-shape summer
kitchen with green
egg platform (egg by
homeowner), fridge,
kegerator and
extended countertop
bar
3' x 4' Pool
equipment pad1' 8"10'1' 6"6'
9'9'
12' 3"12' 3"
R 3'REQUIRED:
(4) 3' LONG 8 GAUGE COPPER WIRE
BONDING POINTS FROM POOL
STEEL CONNECTED TO
EQUIPOTENTIAL BONDING GRID
4" - 6" DEEP AND 18" - 24" FROM
WATERS EDGE.
Bubbler
Skimmer
Side Suction
Wall Return
Main Drains
Plumb Only for Cleaner
Auto Fill
Water /Hose Bib
F Spa Fountain Line
Spa Jets
LED Pool Light
Spa Lights
Existing Gas Tank
LEGEND
G
R
3'
SJ
R
R
Remove existing pavers
and stack them off to the
side to reuse. Also remove
existing bench and dispose
of.
Scale: 1/8" = 1 ft
Name:SHABBY CHIC LLC (ANDREW COWN
Address:1691 ATLANTIC BEACH DR
City, State, Zip:ATLANTIC BEACH, FL 32233
CLIENT INFORMATION
Size:12' X 24'Area:297SQ FT Pool Gallons:8,886
Depth:3' - 5'Perimeter:75 LN FT Spa Gallons:
Plaster Type:CRYSTAL STONE NATURAL Plaster Color:ONYX
POOL SPECIFICATIONS
# of Returns:3 # of Skimmers:1
# of Pool Main Drains:2 FLOOR # of Spa Main Drain:N/A
Cleaning System:PLUMB ONLY # of In-Floors:N/A
# of Vac Lines:1 Type of Robot Vac:PRESSURE
Water Features:BUBBLER Branch Piping:3.0
Trunk Piping:3 Return Piping:2.0
PLUMBING SPECIFICATIONS
Pool Pump:PENTAIR INTELLIFLO VSF 2nd Pump:N/A
Filteration Type:PENTAIR CLEAN & CLEAR Filter Size:200 SQ FT
Heat Pump:N/A Heater:N/A
Chlorinator:PENTAIR INTELLICHLOR Blower:N/A
Pool Automation:N/A Computer Controls:INTELLICONNECT
# of Pool Lights:1 LED (WITH NICHE)# of Spa Lights:N/A
EQUIPMENT SPECICATIONS
Tile Vendor:NOBLE Tile Product #:NEAG 636
Locations:POOL WATERLINE Spillways:N/A
Glass Tile Vendor:N/A Glass Tile Location:N/A
Spa Interior:NA Spa Exterior:N/A
TILE SPECIFICATIONS
Type of Paver:TREMRON Pool Deck Area:SQ FT
Size of Pavers:REUSE EXISTINGPAVERS
Paver Color:Reuse Existing Pavers
Type of Coping:TREMRON Coping Perimeter:122 LN FT
Size of Coping:4" X 9"Coping Color:SAND DUNE
Footer:N/A Retaining Wall:NON STRUCTURAL TREMRONSTONEGATE BLOCK
DECK SPECIFICATIONS
Baby Barrier Screen Enclosure:
Fence: x Pool/Spa Water Alarms: X
SAFETY REQUIREMENTS PER SAFETY CODE
Sales Team:KEVIN CARROLL & CHRIS MYERS
Checked By:JASON WINTER
Drawn By:CHRIS MYERS
Date of Contract:
Date of Drawings:
Contractor & License #KEVIN J. CARROLL, CPC1458340
PAGE DOCUMENT INFORMATION
115 Solana Rd, Suite C
Ponte Vedra Beach, FL 32082
Office 904-543-2626 - CPC 1458340
Construction Drawing
Scale: 1/8" : 1'
Construction Drawing
Scale: 1/8" : 1'
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $515.19
POOL21-0032 Address: 1691 ATLANTIC BEACH DR APN: 169505 1375 $515.19
BUILDING $205.00
BUILDING PERMIT 455-0000-322-1000 0 $205.00
BUILDING PLAN REVIEW $102.50
BUILDING PLAN CHECK 455-0000-322-1001 0 $102.50
PUBLIC WORKS PLAN REVIEW $100.00
PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00
STATE SURCHARGES $7.69
STATE DBPR SURCHARGE 455-0000-208-0700 0 $4.61
STATE DCA SURCHARGE 455-0000-208-0600 0 $3.08
ZONING PLAN REVIEW $100.00
ZONING REVIEW SINGLE AND TWO FAMILY
USES 001-0000-329-1003 0 $100.00
TOTAL FEES PAID BY RECEIPT: R16883 $515.19
Printed: Thursday, August 26, 2021 5:01 PM
Date Paid: Thursday, August 26, 2021
Paid By: Chris Myers
Pay Method: CREDIT CARD 503199238
1 of 1
Cashier: JJ
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R16883