Loading...
348 AQUATIC DR RES21-0298 �';'-L`'%1` Building Permit Application Updated 10/9/18 r ; City of Atlantic Beach Building Department **ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY 7y,, IS REQUIRED. 2Phonje.: (904)A4)247-5826 Email: Building-Dept@coab.us j�C Job Address: V M'th t rL DitIW Permit Number: I\l�SZ I — 02 Legal Description t WR014 3 g-7( i 7-- ZS-29 C RE# 171316 —S L ((AV Valuation of Work(Replacement Cost)$ 1400,ob Heated/Cooled SF Non-Heated/Cooled • Class of Work: ❑New ❑Addition ❑AlterationRepair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial 'Residential • If an existing structure, is a fire sprinkler system installed?: ❑Yes re o • Will tree(s)be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) GR‘ Describe in�d aitthe type of work to be erformed: cry �j ,6arro14 or Ra7Tgi 77 1' f ,Q.�r —tf turrt- 'l p1-K wod) Go v�`- r' Ilk.5t& -f + /4/91-p) G fr J/D/114 4-- ,'14 As f/Nt Sim •)(r liev 011-• Florida Product Approval# Z JO for multiple products use product approval form Property Owner Information Name /POe�� aiti /L-.• Address 3Y6 '9T y ii Dr. City*7tA-(47t Pef State R, Zip 3223 ('Phone v) 240-7-3 429 E-Mail roiled! Y/ 4.14 j ,z-artti Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information ./ Name of Company JM1 a wIVelt, Qualifying Agent Address City State Zip Office Phone Job Site Contact Number State Certification/Registration# E-Mail Architect Name& Phone# ' Engineer's Name&Phone# Workers Compensation Insurer OR Exempt 0 Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECOR NG Y�jR �TICE F OMMENCEMENT. (Signature of Owner or Agent) (Signature of Contr tf or) Signed a d sworn to(o affirmed)before me this49da of Signed and sworn to(or affirme. .efore me this day of ,by ..e. "s , , by (Sig " 'o ) (Signature of Notary) 1.•,‘":.•.. ..:,6A ERIN MA' E STEHL lii 1. . ;•? MY COMMISSIO 1 #GG 266182 %`' ; EXPIRES:Qctober 14,2022 rsf)nall Known O I [ ]Personally Known OR O'-ro.uce• .-n i i a is [ ]Produced Identification Type of Identification: /..--. Type of Identification: Owner Builder Affidavit **ALL INFORMATION HIGHLIGHTED IN "' City of Atlantic Beach Building Department GRAY IS REQUIRED. / 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: I. FLORIDA STATUTES;CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING" REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7), FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY,TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF$25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE,THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE,WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE,THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. . III. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES. OWNERS BEING SUBJECT TO$5,000 PENALTY UNDER FLORIDA STATUTE NO.455-228(1). AN "OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY"CERTIFICATE OF COMPETENCY" OR THE FLORIDA"CONTRACTORS CERTIFICATE"TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. CONTACT THE BUILDING DEPARTMENT(904- 247-5826 OR BUILDING-DEPT@COAB.US) IF IN DOUBT. V. ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. Job Address: 1Y8 4a11471 C-)1 "Ogg/2-7--- i / Owner Name: W 14.61' Phone Number:(122T Mailing Address: � gavel i2 t J A City: �8.01a/e 8�%� State: Zip: 3U-/3 Notarized Signature of Owner W / The e pgks>?fument was acknowledged before me this day of 5 , 20.91, in t - State of Florida, County f VVPi Signature of Notary Pu is � • ERIN MARIE STEW :+�, ;•`•MV COMMISSION#GG 266182 [ ) Personally Knownoduced Identification ;.; ''';i Jam'•r° LXPIRES:October 14.2022 •1%.1117• 0 Type of Identification: Updated 10/24/18 Florida Product Approval HardiePlank® Lap Siding • For use inside HVHZ: o HardiePlank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami-Dade County Florida NOA 07- 0418.04. Consult the HardiePlank product installation instructions on the follow pages for all other installation requirements. • For use outside of HVHZ, o HardiePlank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2298-11 or R1O-2300-11. Consult the HardiePlank product installation instructions on the follow pages for all other installation requirements. HardiePlank®Ii !o Lap Siding E0 JamesHardie EFFECTIVE NOVEMBER 2010 INSTALLATION REQUIREMENTS- PRIMED&COLORPLUS®® PRODUCTS Visitwww.jameshardie.comfor the most recent version, SELECT CEDARMILL© SMOOTH•COLONIAL SMOOTH®•COLONIAL ROUGHSAWN®•BEADED CEDARMILL© BEADED SMOOTH•STRAIGHT-EDGE SHINGLE PLANK IMPORTANT:FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY,AFFECT SYSTEM PERFORMANCE,VIOLATE LOCAL BUILDING CODES,AND VOID THE PRODUCT ONLY WARRANTY.BEFORE INSTALLATION,CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONETM PRODUCT INSTRUCTIONS. INSTALLATION OF HZ1 O®PRODUCTS OUTSIDE AN HZ10®LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONETM APPLIES TO YOUR LOCATION,VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343(866 9HARDIE) STORAGE&HANDLING: © CUTTING INSTRUCTIONS Store flat and keep dry and OUTDOORS INDOORS covered prior to installation.Installing 1.Posmon GI-sir station so that wind will blow dust away from user 1.Cut only using score and snap,or shears(manual,electric or pneumatic). and otheratdrg area. 2.Position cutting station in welt-ventilated area siding wet or saturated may result in 2.use one of the following methods: shrinkage at butt joints.Carry planks a.Best: i.Score and snap ii.Shears(manual,electric or pneunatic) -NEVER use a power saw indoors on edge. Protect edges and corners b.Better: i.Dust reducing circular saw equipped with a -NEVER use a circular saw blade that does not carry the HanlieBlade saw blade trademark from breakage.James Hardie is not HardieBlade1 saw blade and I-EPA vaaxm extraction -NEVER dry sweep—Use wet suppression or HEPA Vacuum c.Good: i.Drat reducing circular saw with a HardieBlade saw blade responsible for (only use for ion,to moderate cutting) damage caused (,��`�' — �� Important Note:For maximum protection(lowest respirable drat production),JamesHardie recommends always using g"Best"-level cuttingmethods where feasible. by improper ���' storage and NIOSH-approved respirators can beused in conjunction with above cutting practices to further reduce dust exposures.Additional exposure information is available at www.jarneshardie.com to help you determine the most appropriate cutting method fa your job requirements.If concern still exists about exposure levels or you handling of the product. do not corn*with the above practices,you should always consult a qualified industrial hygienist or contact James Hardie for further information. 5)083105 GENERAL REQUIREMENTS: • HardiePlankn lap siding can be installed over braced wood or steel studs spaced a maximum of 24"o.c.or directly to minimum 7/16"thick OSB sheathing. Irregularities in framing and sheathing can mirror through the finished application. • HardiePlank®lap siding can also be installed over foam insulation/sheathing up to 1"thick.When using foam insulation/sheathing,avoid over-driving nails (fasteners),which can result in dimpling of the siding due to the compressible nature of the foam insulation/sheathing.Extra caution is necessary if power-driven nails(fasteners)are used for attaching siding over foam insulation/sheathing. • A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements.James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap•Weather Barrier,a non-woven non-perforated housewrapl,which complies with building code requirements. • When installing James Hardie products all clearance details in figs.3,4,5,6,7,8,&9 must be followed. • Adjacent ed grad slope from building in accordance with local building Construction Wall Single nsWallFigure 1 coieiypica amum of in the first i • Do not use HardiePlank lap siding in fascia or trip applications. water-resistive barrier let-in bracing • Do not install James Hardie products,such that they may remain in contact with standing water. plywood or 24"o.c.max. • HardiePlank lap siding may be installed on flat vertical wall applications only. OSB sheathing i • For larger projects,including commercial and multi-family projects,where the span of the r wall is significant in length,the designer and/or architect should take into consideration \1,1,/the coefficient of thermal expansion and moisture movement of the product in their design.These values can be found in the Technical Bulletin"Expansion Characteristics of James Hardie®Siding Products"at www.JamesHardie.com.• DO NOT use stain on James Hardie®products. INSTALLATION: JOINTTREATMENT*(Required forColorRus®Finish,Recommended for Primed product)James Hardie does not recommend the use of caulk at field butt joints.Figure 2 water-resistive stdInstall factory finished edgestogether at butt joints.o—T plank, oo,joint flashing _ �f BkGanuedge -resistive nstall p cols in arriermoderate contact ( '411"I Install a 1 tl4"starter slip to o ensue a consistent plank angle • *For other jointing options,refer to local building code or NER 405 **As required by local building code **"Apply caulk in accordance with caulk manufacturers written application instructions. leave appropriate gap between 'For additional information on HardieWrap wm Weather Barrier,consult James Hardie at 1-866-4Hardie or ww.hardiewrap.coplanks and trim,then caulk* WARNING:AVOID BREATHING SILICA DUST James Hardie®products contain respirable crystalline silica,which is known to the State of California to cause cancer and is considered by ARC and NIOSH to be a cause of cancer from some occupational sources.Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis,and has been linked with other diseases.Some studies suggest smoking may increase these risks. During installation or handling:(1)work in outdoor areas with ample ventilation;(2)use fiber cement shears for cutting or,where not feasible,use a HardieBlade saw blade and dust-reducing circular saw attached to a HEPA vacuum;(3)warn others in the immediate area;(4)wear a properly-fitted,NIOSH-approved dust mask or respirator(e.g.N-95)in accordance with applicable government regulations and manufacturer instructions to further limit respirable silica exposures. During clean-up,use NEPA vacuums or wet cleanup methods-never dry sweep. For further information,refer to our installation instructions and Material Safety Data Sheet available at www.jameshardie.com or by calling 1-800-9HARDIE(1-800-942-7343). FAILURE TO ADHERE TO OUR WARNINGS,MSDS,AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH. SD060905 HS0920-P1/4 10/10 /fir ro CLEARANCES the juncture of the roof and vertical Install siding and trim products in compliance Maintain a 1" 2"clearance between surfaces,flashing and counterflashing shall with local building code requirements for James Hardie products and decking be installed per the roofing manufacturer's clearance between the bottom edge of the Maintain a 1"-2"clearance material. instructions.Provide a 1"-2"clearance siding and the adjacent finished grade. between James Hardie' Fi r ure 5 between the roofing and the bottom edge of products and paths,steps f the siding and trim. siding water Figure 3 stud and driveways. g resistive water-resistive barrier Figure 6 r bare '��-� Figure 4 j t 1"-2" deck material /,( concrete y 111 1 2 ..._ _./1--- 1 T foundation 1'-2' 1 I_ 11 /— \ 101st II flashing FillilaftFi_ •4' '111 10/ 111111 \ III �.�i edger flashing i01111111111111111111111Hard ePlank® I.min lap siding 'Figure 9 Maintain a 1/4"P clearance Maintain a minimum 1"gap < ` KICKOUT FLASHING senoras x '' Because of the volume of water that can pour down between the bottom of James between gutter end caps and se" ^g/.`, .' nt�; ��9! a sloped roof,one of the most critical flashing Hardie products and horizontal siding&trim. t'4„. " > details occurs where a roof intersects a sidewall. flashing.Do not caulk gap. Figure 8 vesme_ame The roof must be flashed with step flashing. Where 9 9 p g eaves me ewt ���� the roof terminates,install a kickout to deflect water nig Figure 7 ��' ` away from the siding. m siding ft is best to install a self adhering membrane on the Do not 114'gap siding Or- lwall before the subfascia and trim boards are nailed 11 caulk +- t !! I; in place,and then come back to install the kickout. fascia Figure 9,Kickout Flashing To prevent water from dumping behind the siding and the flashing 1111� end of the roof intersection,install a"kickout"of sufficient length and angle to direct the gutter and end cap water running down the roof away from the siding. FASTENER REQUIREMENTS ** Blind Nailing is the preferred method of installation for all HardiePlank®lap siding products BLIND NAILING FACE NAILING Nails-Wood Framing Nails-Wood Framing •Siding nail(0.09"shank x 0.221"HD x 2"long) •6d(0.113"shank x 0.267"HD x 2"long) • 11ga.roofing nail(0.121"shank x 0.371"HD x 1.25"long) •Siding nail(0.09"shank x 0.221"HD x 2"long) Screws-Steel Framing Screws-Steel Framing •Ribbed Wafer-head or equivalent(No.8 x 1 1/4"long •Ribbed Bugle-head or equivalent(No.8-18 x 1-5/8"long x x 0.375"HD)Screws must penetrate 3 threads into metal framing. 0.323"HD)Screws must penetrate 3 threads into metal framing. Nails-Steel Framing Nails-Steel Framing •ET&F Panelfast`a nails or equivalent(0.10"shank x 0.313"HD x 1-1/2"long) •ET&F pin or equivalent(0.10"shank x 0.25"HD x 1-1/2"long) Nails must penetrate minimum 1/4"into metal framing. Nails must penetrate minimum 1/4"into metal framing. OSB minimum 7/16" OSB minimum 7/16" •11ga.roofing nail(0.121"shank x 0.371"HD x 1.75"long) •Siding nail(0.09"shank x 0.221"HD x 1-1/2"long)* •Ribbed Water-head or equivalent(No.8 x 1 5/8"long x 0.375"HD). stud 24"----------w O.0 max. V 24" Figure 10 Figure 11 -, _- 1 1/4"min. stud - - O C max overlap water-resistive Minimum overlap -- — -- barrier �V _ _ o for Both Face --o and Blind Nailing —- - - II blind nail \ _ - _ - ° 3/4"-1" — — I I jEIter-r min.11/4" �Il�r face nail over1M111 esistive ) barrier I water-resistive 1 1/4"min. barrier overlap Laminate sheet to be removed immediately after installation of each course for ColorPlus®products. $ The illustration(figure 9)and associated text was reprinted with permission of THE JOURNAL OF LIGHT CONSTRUCTION.For subscription information,visit www.jlconline.com. • When face nailing to OSB,planks must be no greater than 9 1/4"wide and fasteners must be 12"o.c.or less. **Also see General Fastening Requirements;and when considering alternative fastening options refer to James Hardie's Technical Bulletin USTB 17-Fastening Tips for HardiePlank®Lap Siding. HS0920-P2/4 10/10 y ro GENERAL FASTENING REQUIREMENTS •Consult applicable code compliance report for correct fasteners type and Fasteners must be corrosion resistant,galvanized,or stainless steel. placement to achieve specified design wind loads. Electro-galvanized are acceptable but may exhibit premature corrosion. •NOTE:Published wind loads may not be applicable to all areas where James Hardie recommends the use of quality,hot-dipped galvanized Local Building Codes have specific jurisdiction.Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. nails. James Hardie is not responsible for the corrosion resistance of •Drive fasteners perpendicular to siding and framing. fasteners. Stainless steel fasteners are recommended when installing •Fastener heads should fit snug against siding(no air space).(fig.A) James Hardie®products near the ocean,large bodies of water,or in •Do not over-drive nail heads or drive nails at an angle. very humid climates. •ff nail is countersunk,caulk nail hole and add a nail.(fig.B) PNEUMATIC FASTENING •For wood framing,under driven nails should be hit flush to the plank with a James Hardie products can be hand nailed or fastened with a pneumatic tool. hammer(For steel framing,remove and replace nail). Pneumatic fastening is highly recommended. Set air pressure so that the •Do not use aluminum fasteners,staples,or clipped head nails. fastener is driven snug with the surface of the siding.A flush mount Snug Flush Countersunk, 611114� attachment on the pneumatic tool is recommended. This will help control the Caulk& 41 depth the nail is driven.If setting the nail depth proves difficult,choose a 'add nail MO setting that under drives the nail. (Drive under driven nails snug with a do not under DO NOT smooth faced hammer-Does not apply for installation to steel framing). Figure A Figure B drive nails STAPLE CAULKING PAINTING For best results use an Elastomeric Joint Sealant complying DO NOT use stain on James Hardie'products.James Hardie products must be with ASTM C920 Grade NS,Class 25 or higher or a Latex painted within 180 days for primed product and 90 days for unprimed.100% Joint Sealant complying with ASTM C834.Caulking/Sealant acrylic topcoats are recommended. Do not paint when wet.For application rates must be applied in accordance with the caulking/sealant refer to paint manufacturers specifications.Back-rolling is recommended if the manufacturer's written instructions or ASTM C1193. siding is sprayed. COLORPLUS®TECHNOLOGY CAULKING,TOUCH-UP& LAMINATE •Touch up nicks,scrapes and nail heads using the ColorPluse Technology touch-up applicator.Touch-up paint should be used sparingly. If large areas require touch-up,replace the damaged area with new HardiePlank"lap siding with ColorPlus Technology. •Laminate sheet must be removed immediately after installation of each course. •Terminate non-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPlusu product dealer, •Treat all other non-factory cut edges using the ColorPlus Technology edge coaters,available from your ColorPlus product dealer. PAINTING JAMES HARDIE®SIDING AND TRIM PRODUCTS WITH COLORPLUS®TECHNOLOGY When repainting ColorPlus products,James Hardie recommends the following regarding surface preparation and topcoat application: •Ensure the surface is clean,dry,and free of any dust,dirt,or mildew •Repriming is normally not necessary •100%acrylic topcoats are recommended •DO NOT use stain or oil/alkyd base paints on James Hardie'products •Apply finish coat in accordance with paint manufacturers written instructions regarding coverage,application methods,and application temperature COVERAGE CHART/ESTIMATING GUIDE Number of 12'planks,does not include waste COVERAGE AREA LESS OPENINGS HARDIEPLANK'LAP SIDING WIDTH SQ 51/4 6114 71/4 7112 8 81/4 91/4 91/2 12 (1 So=100 sq.tt) (exposure) 4 5 6 6114 6 3/4 7 8 8114 10 314 1 25 20 17 16 15 14 13 13 9 2 50 40 33 32 30 29 25 25 19 3 75 60 50 48 44 43 38 38 28 4 100 80 67 64 59 57 50 50 37 5 125 100 83 80 74 71 63 63 47 6 150 120 100 96 89 86 75 75 56 7 175 140 117 112 104 100 88 88 65 8 200 160 133 128 119 114 100 100 74 9 225 180 150 144 133 129 113 113 84 10 250 200 167 160 148 143 125 125 93 11 275 220 183 176 163 157 138 138 102 12 300 240 200 192 178 171 150 150 112 13 325 260 217 208 193 186 163 163 121 14 350 280 233 224 207 200 175 175 130 15 375 300 250 240 222 214 188 188 140 16 400 320 267 256 237 229 200 200 149 17 425 340 283 272 252 243 213 213 158 18 450 360 300 288 267 257 225 225 167 19 475 380 317 304 281 271 238 238 177 20 500 400 333 320 296 286 250 250 186 This coverage chart is meant as a guide.Actual usage is subject to variables such as building design.James Hardie does not assume responsibility for over or under ordering of product. RECOGNITION: In accordance wlth ICC-ES Legacy Report NER-405,HardePlank'lap siding is recognized as a suitable alternate to that specified in the BOCA National Building Code/1999.the 1997 Standard Building Code.the 1997 Uniform Building Code,the 1998 International One-and Two-Family Dwelling Code,the 2003 International Building Code,and the 2003 International Residential Code for One-and Two- Family Dwellings. HardiePlank lap siding is also recognized for application in the following: City of Los Angeles Research Report No 24862.State of Fbnda listing FL#889,Dade County,Fbrida NOA No.02-0729.02. U S.Dept of HUD Materials Release 1263c,Texas Deparhnent of Insurance Product Evaluation EC-23,City of New York MEA 223-93-M,and California DSA PA-019.These documents should also be consulted for additional information concerning the suitability of this product for specific applications. HS0920-P3/4 10/10 ',ME. ®2010 James Hardie Technology Limited.All rights reserved. Additional Installation Information, TM,aSes and®echnteol trademarks or ris airegi dt traredema m of Warranties,and Warnings are available at JamesHardieyisaregisteredtrademark 9 JamesHardie of James Hardie Technology Limited. WWW.f ameStlardle.COm Panelfast is a registered trademark of ET&F Fastening Systems,Inc. HS0920-P4/4 10/10