469 11th St ROW21-0059 Verizon AttenasOWNER:ADDRESS:CITY:STATE:ZIP:
CITY OF ATLANTIC BEACH 800 SEMINOLE RD ATLANTIC BEACH FL 32233-5444
COMPANY:ADDRESS:CITY:STATE:ZIP:
J CROMPTON ELECTRIC INC 1290 OLD CONGRESS AVE WEST PALM BEACH FL 323409
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
172026 0000 SECTION LAND
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
469 11TH ST RIGHT OF WAY COMMERCIAL
RIGHT OF WAY
VERIZON - RELOCATE
ANTENNAS AT WATER
TOWER
$21000.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247-
5814) to request an Erosion and Sediment Control Inspection prior to start of construction.
2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 9/23/2021
PERMIT NUMBER
ROW21-0059
ISSUED: 9/23/2021
EXPIRES: 12/22/2021
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
3 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
4 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
5 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
2 of 2Issued Date: 9/23/2021
PERMIT NUMBER
ROW21-0059
ISSUED: 9/23/2021
EXPIRES: 12/22/2021
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
ROW21-0059
'r Building Permit Application Updated 10/9/18
**ALL INFORMATION
HIGHLIGHTED IN GRAY
IS REQUIRED.
,,
.~ City of Atlantic Beach Building Department
800 Seminole Road, Atlantic Beach, Fl 32233
Phone: (904) 247-5826 Email: Building-Dept@coab.us
Job Address: 469 11th Street. Atlantic Beach 32233 (VZW Site 610397) Permit Number: _________ _
Legal Description PT GOVT LOT 5 RECD DBK 1761-104 RE# 172026-0000
Valuation of Work (Replacement Cost) $_2_1_,o_oo _____ Heated/Cooled SF _____ Non-Heated/Cooled _____ _
• Class of Work: □New □Addition EAlteration □Repair □Move □Demo □Pool □Window/Door
• Use of existing/proposed structure(s): ECommercial □Residential
• If an existing structure, is a fire sprinkler system installed?: □Yes ENo
• Will treelsl be removed in association with nronosed nroiect? □Yes /must submit seoarate Tree Removal Permit) 15aNo
Describe in detail the type of work to be performed:
At existing water tower cellular site, relocate antennas to temporary cell-on-wheels tower.
Florida Product Approval# ___________________ for multiple products use product approval form
Property Owner Information
Name Verizon Wireless -Lessee Address 7701 Telecom Parkway
City Tampa State _F_L __ Zip 33637 Phone 410-952 -3860 -Paul Bailey/Agent
E-Mail paul.bailey@caawireless.com
Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) ____________________ _
Contractor Information
Name of Company J. Crompton Electric, Inc.
Address 1290 Old Congress Avenue
Office Phone 561-588-6559
State Certification/Registration # SCC131151549
Qualifying Agent Jonathan Crompton
City West Palm Beach State _F_L __ Zip 33409
Job Site Contact Number _______________ _
E-M a ii pennitting@jcromptonelectric.com
Architect Name & Phone# ___________________________________ _
Engineer's Name & Phone# Hugh Reilly, P.E. / CBVR Telecom Design Phone: 770-853 -1233
Workers Compensation Insurer ________________ OR Exempt □ Expiration Date _______ _
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this
permit, there may be additional restrictions applicable t o this property that may be found in the public records of this county, and
there may be additional permits required from other governmental entities such as water management districts, state agencies, or
federal agencies.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN F NCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
U N E F MENCEMENT.
Signed and sworn to (or affirmed) before me this_/_ day of
Q"/)T@ll.8c7f , '2-t>Z..I , by /Ji u{ 6?A t fe'o/
... <t1,.' 'lii•·•.JSilmatuc U \ . f!~"\:, Notary Pub'lic · a e f Flonda
\~OOl} Commission# GG 328639
··/for f\-'<!,;.-· My Comm. Expires Apr 29, 2023
[ Personally Known OR .......... Bonded throuih National Notary ,\s1,11.
[ ] Produced ldentificati~.,,..,..,..,.,..,.. __ .._ __ ,.
Type of Identification: _____________ _
(Signature of Contractor)
Signed and sworn to (or affirmed) before me this _L day of
-sr-rran.9~~ z.c ,_ r fly ;;;}1,1 '4 nft>,..; CMm. flmAl ,L~V\~· .
/"J.-1-.' \,t.. MARK MORRIS ("~ :I Notary Publk · State of Florida ,~~~i Comm1ss1on ;/ HH 110847
[ Personally Known OR ··· ... or F;c.°rf.-My Comm. Expires Ju ! 21, 2025
[ ] Produced Identification Bondec through Nationai Notary Assn. Type of Identification: ..,.. ___ ,... ______ ...,..,;.,
ROW21-0059
Site Name: Mayport Road
Site ID: 100402
TIIIS FORM PREPARED BY
Tirso M. Carreja, Jr.
Fowler White Boggs P.A.
501 E. Kennedy Blvd., Suite 1700
Tampa, Florida 33602
Doc# 2011055287, OR BK 15539 Page 477.
Number Pages: 3
Recorded 03/10/2011 at 12:32 PM,
JIM FULLER CLERK CIRCUIT COURT DUVAL
COUNTY
RECORDING $27.00
FIRST AMENDED SHORT FORM LEASE
-Jl.--
This First Amended Short Form Lease is made this ,.;), l{: day a£ LLOv , 2011, between
Delaware limited City of Atlantic Beach (the "OWNER"), and Verizon Wireless Personal Communications
partnership d/b/a Verizon Wireless ("LESSEE").
I. Owner and LE~SEE entered into a PCS Site Lease, dated November 9, 1995 (the "Lease"), as amended
on c,_ • c 2-4 , 2011, by that certain First Amendment to PCS Site Lease (the "First Amendment")
for the lease of a IJOrt on of certain real property and a communications facility (the "Site"), located at 469 11"
Street, Atlantic Behe , Duval County, Florida, together with that certain Short Form Lease (the "Short Form
Lease"), recorded in O.R. Book 8391 Page 201 of the Public Records of Duval County, Florida.
2. OWNER and LESSEE execute this First Amended Short Fo1m Lease to delete sketch on Attachment
"A" of Short Form Lease and replace the sketch with Attachment "A-1", which depicts the 202 square feet of
ground space leased to Lessee, under the terms of the Lease and the First Amendment.
3. Nothing contained herein shall be deemed to impair or change the priority of the Lease with respect to
any other encumbrance on the Site. All terms and provisions of the Short Form Lease not expressly modified herein
shall remain in full force and effect.
4. The 1e1ms, covenants and provisions of the Lease of which this is the First Amended Short Form Lease,
shall extend to and be binding upon the respective executors, administrators, heirs, successors and assigns of O\VNER
and LESSEE.
[Signatures on Following Page]
IN WITNESS WHEREOF, hereunto and to a duplicate hereof, OWNER and LESSEE have caused this Amended
Sholi Form Lease to be duly executed on the date below.
O\Vl\1ER:
City of Atlantic Beach
City Clerk
WITNESSES: LESSEE:
Verizon \Vireless rs a ommunications LP,
a Delaware · · p n hip d/b/a Verizon \Virelcss
By:
Name: H . eutenegger
~~::: Area Vice~T~~n\){)\}
OWNER NOTARY ACKNOWLEDGi\IENT:
LESSEE NOTARY ACKNOWLEDGMENT:
STATE OF NORTH CAROLINA
COUNTYOFMECKLENBURG f\ll rt. ~\\
The foregoing instrument was acknowledged before me this ~c!'\-'1'7-__ day of--c'\_ 's~---__:,.::,c,-~~l,-e 2ttt'6':by Hans F. Leutenegger, as Area
Vice President Net\vork of · Vireless Personal Communications LP, a Delaware limited n rship d/b/a Verizon Wireless, on behalf of
the partnership. He is,f\!er~ofr~,a::lly=kn:o:~:n::.=m=e~o=r=ha=s~p=ro=d=u=cc=d=-=-=-=-=-=-=-=-=-=-~=-=-Q--~as entification. vnre-Car .. -(1 . f\, n
(Printed!Typed/Stamped Notal)' N"l''FNNE CARLISLE ~
Notary Public, North Carolina
Mecklenburg County
/ _~~--_ . _ My ~;~~~i~~~~g;fires
ATTACHMENT "A-1"
Site Sketch
EXISTING HANO HOLE\ 16'-8"
D
EXISTING POWER~-------
POLE WITH GUY WIRE
~· .. "'-" T INLET
EXISTING HAND ,_,,1
HOLE I
\
\
--8'
EXISTH'lG LESSEE 8'-0" x 15'-0"
CONCRETE EQUIPMENT PAD
WITH EQUIPMENT CABINETS ON
2'-5" x 15'•2" I-BEAM OVERHANGING
THE PAD 1'·7"
EXISTING ICE BRIDGE
EXISTING WATER TANK
LEG FOUNDATION
EXISTING LESSEE 15 KW
GENERATOR WITH 97 GAL
BELLY TANK ON 3'--0" x 3'--0"
\
CONCRETE EQUIPMENT PAD
TO BE REPLACED WITH
7'-9" 30 KW LP GENERATOR ON
EXISTING CONCRETE PAD
EXISTING LESSEE
UTILITY RACK
PROPOSED LESSEE 3'-0" x 4'--0"
CONCRETE PAD EXTENSION FOR
PROPOSED GENERATOR
PROPOSED LESSEE GAS LINE ROUTE
EXISTING LESSEE 120 GAL
PROPANE TANK
TO BE REMOVED
,( EXISTING TREE
/ / ~ 10' RADIUS SAFETY
BUFFER FROM LP
TANK FILL POINT
PROPOSED LESSEE 500 GALLON LP FUEL TANK
ON 4'·0" x 10'--0" CONCRETE PAD
,-x--x--x--x--x--x--x--x--x--x--x~
i
EXISTING V11'1YL /1
FENCF I
I J~
469 11th ST ROW21-0059
craig land l associates
July 2, 2021
To Whom it May Concern,
Craig & Associates is a consultant for Verizon Wireless and has been hired to submit bui lding
permit applications on their behalf. Craig and Associates has hired and currently e_mploys Paul
Thomas Bailey as a Permit Special ist to prepare building permit documents and tddeiiver sai~
documents to jurisdictions throughout the State of Florida.
Please accept this notarized letter as confirmation that Paul Bailey is qualified to represent
Cra ig and Associates, Verizon Wireless and building contractors as properly authorized to you .
Sincerely,
~
~ert
Vice President
Craig & Associates
727-457-3646
wendy.reinert@caawireless.com
Subscribed and sworn before me this .J.rJctay of , :=:s:;4 1\ y
' \
by We,\~ Re,,, ne~t
. 2021,
Personally Known \L . or Produced Identification ____ _
Type ofldentification Produced _______ _
Signe d ~2f«J34;~ (Notary)
~~v "CJt FLORENCE B STEPHENS ~~ Commlsslon #GG357747
-; ~: Expires July 31, 2023
~~ OF f\.~,$! -iondtd TlllU lludget.NolalySerYlceJ
Printed Name fua -enr<e r/J. 2tefHtn.J (Notary)
Corporate Office: 1324 Seven Springs Blv d. #314, New Po rt Rich ey , FL 3465 5
ROW21-0059verizon✓
PERMIT APPLICATION AUTHORIZATION
Charlie Craig & Associates, LLC and representatives thereof, are herby authorized to
act on behalf of Cellco Partnership d/b/a Verizon Wireless ("Verizon Wireless") or
("Applicant") to apply for and obtain the necessary building permits associates with
the application in order for the Applicant to upgrade its facilities at the
Telecommunications Site ("Site").
STATE OF FLORIDA D _
couNTY oF /2ci m ex::::ach
Applicant:
Cellco Partnership
d/b/a Verizon Wireless
By: onathan Montenegro
Title: Sr. Real Estate Manager
The foregoing instrument was acknowledged before me
this 2(.n-h day of JGCr, UW'\ ~ . 2021 by
Jhonathan Montenegro, who is pers ally known to me. 1) to::.i~=4 (NOTARY SEAL) \~ :"j Expns: August 27, 2023
~,~t;i,t' ,: ,~ Bonded Thru Aaron Notary
SignatU<eofNotary, ~
Name of Notary: kAT7~/ C,( CfE. D
4700 Exchange Court, Suite 110, Boca Raton, FL 33431
tnxTower Report - version 8.1.1.0
Date: August 03, 2021
Cale Lamothe SMW Engineering Group, Inc.
Verizon Wireless 158 Business Center Drive
7701 E Telecom Parkway Birmingham, AL 35244
Temple Terrace, FL 33637 (205) 252-6985
Subject: Structural Analysis Report
Carrier Designation: Verizon Co-Locate
Project Number: 16567179
Location Number: 610397
Carrier Site Name: Selva Marina Relo.
Engineering Firm Designation: SMW Engineering Project Number: 21-5291
Site Data: 469 11th Street, Atlantic Beach, FL 32233 (Duval County)
Latitude 30° 20' 10.22'', Longitude -81° 24' 19.85''
102 Foot – Cow/Colt
Dear Cale Lamothe,
SMW Engineering is pleased to submit this “Structural Analysis Report” to determine the structural integrity
of the above-mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
Proposed Equipment Configuration Sufficient Capacity
This analysis utilizes an ultimate 3-second gust wind speed of 129 mph as required by the 2020 Florida Building
Code 7th Edition and Pinellas County Requirements. Applicable standard references and design criteria are
listed in Section 2 – Analysis Criteria.
Respectfully submitted by:
Jeremy Sharit
Project Engineer
FL CA #33693
E N G I N E E R I N G G R O U P, I N C.
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 2
tnxTower Report - version 8.1.1.0
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Proposed Equipment Configuration
3) ANALYSIS PROCEDURE
Table 2 - Documents Provided
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 3 - Section Capacity (Summary)
4.1) Recommendations
5) APPENDIX A
tnxTower Output
6) APPENDIX B
Base Level Drawing
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 3
tnxTower Report - version 8.1.1.0
1) INTRODUCTION
This tower is a 102’-0” Cow/Colt Tower.
2) ANALYSIS CRITERIA
Building Code: 2020 FBC, 7th Edition (2018 IBC)
TIA-222 Revision: TIA-222-H
Risk Category: II
Ultimate Wind Speed: 129 mph
Exposure Category: C
Topographic Factor: 1
Service Wind Speed: 60 mph
Table 1 - Proposed Equipment Configuration
Mounting
Level (ft)
Center
Line
Elevation
(ft)
Number
of
Antennas
Antenna
Manufacturer Antenna Model
Number
of Feed
Lines
Feed
Line
Size (in)
102.0 102.0 3 Commscope NHH-65B-R2B 18 1/2
3) ANALYSIS PROCEDURE
Table 2 - Documents Provided
Document Remarks Reference Source
RFDS Verizon - Verizon
Tower Drawings Peak Industries, Inc - Verizon
3.1) Analysis Method
tnxTower (version 8.1.1.0), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) Tower and structures were built in accordance with the manufacturer’s specifications.
2) The tower and structures have been maintained in accordance with the manufacturer’s
specification.
3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
This analysis may be affected if any assumptions are not valid or have been made in error. SMW
Engineering should be notified to determine the effect on the structural integrity of the tower.
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 4
tnxTower Report - version 8.1.1.0
4) ANALYSIS RESULTS
Table 3 - Section Capacity (Summary)
Section
No. Elevation (ft) Component Type Size Critical
Element P (lb) SF*P_allow
(lb) %
Capacity Pass / Fail
L1 102 - 82 Pole HSS5x5x1/4 1 -13911.60 54410.10 29.8 Pass
Guy A@102 3/8 15 7208.05 9240.00 78.0 Pass
Guy B@102 3/8 14 7204.92 9240.00 78.0 Pass
Guy C@102 3/8 13 7204.92 9240.00 78.0 Pass
L2 82 - 62.2917 Pole HSS6x6x1/4 2 -28534.00 30979.50 92.1 Pass
Guy A@79.9254 3/8 9 8098.28 9240.00 87.6 Pass
Guy B@79.9254 3/8 8 8090.84 9240.00 87.6 Pass
Guy C@79.9254 3/8 7 8090.84 9240.00 87.6 Pass
L3 62.2917 -
42.875 Pole HSS7x7x1/4 3 -29139.60 50368.70 74.9 Pass
L4 42.875 - 23.75 Pole HSS8x8x1/4 4 -38458.60 63273.80 71.3 Pass
Guy A@41.8684 3/8 12 6336.44 9240.00 68.6 Pass
Guy B@41.8684 3/8 11 6334.04 9240.00 68.6 Pass
Guy C@41.8684 3/8 10 6334.04 9240.00 68.6 Pass
L5 23.75 - 4.917 Pole HSS9x9x1/4 5 -39820.30 91286.00 44.8 Pass
L6 4.917 - 0 Pole HSS10x10x1/4 6 -40035.90 126190.00 35.0 Pass
Summary
Pole (L2) 92.1 Pass
Guy A (L2) 87.6 Pass
Guy B (L2) 87.6 Pass
Guy C (L2) 87.6 Pass
Rating = 92.1 Pass
Structure Rating (max from all components) = 92.1%
4.1) Recommendations
The tower has sufficient capacity to carry the proposed loads with the following conditions.
All of the guy wire sizes should be 3/8” at 15% initial tension. The anchor radius should be 21’-6” but
no closer to the base. For the anchor at radius 21’-6” there will need to be 21,472 pounds of
anchorage weight. If these conditions are not met as stated, then this analysis is void.
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 5
tnxTower Report - version 8.1.1.0
APPENDIX A
TNXTOWER OUTPUT
Consulting Engineers
SMW Engineering
158 Business Center Drive
Birmingham, AL 35244
Phone: (205) 252-6985
FAX: (205) 795-7262
Job: Selva Marina Relo COW
Project: 21-5291
Client: Verizon Wireless Drawn by: Joe McAllister App'd:
Code: TIA-222-H Date: 08/03/21 Scale: NTS
Path: C:\Work from Home\21-5291 SELVA MARINA RELO TEMP\TNX Files\21-5291 Selva Marina Relo Temp.eri Dwg No. E-1
3
/
8
E
H
S
L
C
=
8
2
.
7
0
f
t
I
T
=
1
5
%
R=21.50 ft
3
/
8
E
H
S
L
C
=
4
6
.
9
1
f
t
I
T
=
1
5
%
3
/
8
E
H
S
L
C
=
1
0
4
.
2
0
f
t
I
T
=
1
5
%
102.0 ft
82.0 ft
62.3 ft
79.9 ft79.9 ft79.9 ft
42.9 ft
23.8 ft
41.9 ft41.9 ft41.9 ft
4.9 ft
0.0 ft
6766 lb
20378 lb
2
1
4
7
2
l
b
ALL REACTIONS ARE FACTORED
REACTIONS - 129 mph WIND
TORQUE 17 lb-ft
1072 lb
SHEAR
12908 lb-ft
MOMENT
40036 lb
AXIAL
ARE FACTORED
ALL REACTIONS
S
e
c
t
i
o
n
1
2
3
4
5
6
S
i
z
e
HS
S
5
x
5
x
1
/
4
HS
S
6
x
6
x
1
/
4
HS
S
7
x
7
x
1
/
4
HS
S
8
x
8
x
1
/
4
HS
S
9
x
9
x
1
/
4
HS
S
1
0
x
1
0
x
1
/
4
L
e
n
g
t
h
(
f
t
)
20
.
0
0
19
.
7
1
19
.
4
2
19
.
1
3
18
.
8
3
4.
9
2
G
r
a
d
e
A5
0
0
-
4
6
W
e
i
g
h
t
(
l
b
)
31
2
.
4
35
1
.
4
40
7
.
7
46
2
.
1
51
4
.
6
14
9
.
9
21
9
8
.
0
PLAN
R=21.50 ft R=21.50 ft
R=21.50 ft
R=21.50 ft R=21.50 ft
R=21.50 ft
R=21.50 ft R=21.50 ft
R=21.50 ft
NHH-65B-R2B 102 NHH-65B-R2B 102 NHH-65B-R2B 102DESIGNED APPURTENANCE LOADING
TYPE TYPEELEVATION ELEVATION
NHH-65B-R2B 102
NHH-65B-R2B 102
NHH-65B-R2B 102
MATERIAL STRENGTH
GRADE GRADEFy FyFu Fu
A500-46 46 ksi 62 ksi
TOWER DESIGN NOTES
1. Tower is located in Duval County, Florida.
2. Tower designed for Exposure C to the TIA-222-H Standard.
3. Tower designed for a 129 mph basic wind in accordance with the TIA-222-H Standard.
4. Deflections are based upon a 60 mph wind.
5. Tower Risk Category II.
6. Topographic Category 1 with Crest Height of 0.00 ft
7. TOWER RATING: 92.1%
I I
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 6
tnxTower Report - version 8.1.1.0
Tower Input Data
The tower is a Cow/Colt.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
Tower is located in Duval County, Florida.
Tower base elevation above sea level: 7.00 ft.
Basic wind speed of 129 mph.
Risk Category II.
Exposure Category C.
Simplified Topographic Factor Procedure for wind speed-up calculations is used.
Topographic Category: 1.
Crest Height: 0.00 ft.
Deflections calculated using a wind speed of 60 mph.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Safety factor used in guy design is 1.
Tower analysis based on target reliabilities in accordance with Annex S.
Load Modification Factors used: Kes(Fw) = 0.95.
Maximum demand-capacity ratio is: 1.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not
considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules
Consider Moments - Horizontals Assume Legs Pinned √ Calculate Redundant Bracing Forces
Consider Moments - Diagonals √ Assume Rigid Index Plate Ignore Redundant Members in FEA
Use Moment Magnification √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression
√ Use Code Stress Ratios √ Use Clear Spans For KL/r √ All Leg Panels Have Same Allowable
√ Use Code Safety Factors - Guys √ Retension Guys To Initial Tension Offset Girt At Foundation
Escalate Ice Bypass Mast Stability Checks √ Consider Feed Line Torque
Always Use Max Kz √ Use Azimuth Dish Coefficients Include Angle Block Shear Check
Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-H Bracing Resist.
Exemption
√ Include Bolts In Member Capacity √ Autocalc Torque Arm Areas Use TIA-222-H Tension Splice
Exemption
√ Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles
√ Secondary Horizontal Braces Leg Sort Capacity Reports By Component Include Shear-Torsion Interaction
Use Diamond Inner Bracing (4 Sided) √ Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow
√ SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets
SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole Without Linear Attachments
Pole With Shroud Or No
Appurtenances
Outside and Inside Corner Radii Are
Known
Pole Section Geometry
Section Elevation
ft
Section
Length
ft
Pole
Size
Pole
Grade
Socket Length
ft
L1 102.00-82.00 20.00 HSS5x5x1/4 A500-46
(46 ksi)
L2 82.00-62.29 19.71 HSS6x6x1/4 A500-46
(46 ksi)
L3 62.29-42.88 19.42 HSS7x7x1/4 A500-46
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 7
tnxTower Report - version 8.1.1.0
Section Elevation
ft
Section
Length
ft
Pole
Size
Pole
Grade
Socket Length
ft
(46 ksi)
L4 42.88-23.75 19.13 HSS8x8x1/4 A500-46
(46 ksi)
L5 23.75-4.92 18.83 HSS9x9x1/4 A500-46
(46 ksi)
L6 4.92-0.00 4.92 HSS10x10x1/4 A500-46
(46 ksi)
Tower
Elevation
ft
Gusset
Area
(per face)
ft2
Gusset
Thickness
in
Gusset Grade Adjust. Factor
Af
Adjust.
Factor
Ar
Weight Mult.
Double Angle
Stitch Bolt
Spacing
Diagonals
in
Double Angle
Stitch Bolt
Spacing
Horizontals
in
Double Angle
Stitch Bolt
Spacing
Redundants
in
L1 102.00-
82.00
1 1 1
L2 82.00-
62.29
1 1 1
L3 62.29-
42.88
1 1 1
L4 42.88-
23.75
1 1 1
L5 23.75-4.92 1 1 1
L6 4.92-0.00 1 1 1
Guy Data
Guy
Elevation
ft
Guy
Grade
Guy
Size
Initial
Tension
lb
%
Guy
Modulus
ksi
Guy
Weight
plf
Lu
ft
Anchor
Radius
ft
Anchor
Azimuth
Adj.
°
Anchor
Elevation
ft
End
Fitting
Efficiency
%
79.9254 EHS A
B
C
3/8
3/8
3/8
2310.00
2310.00
2310.00
15%
15%
15%
23000
23000
23000
0.273
0.273
0.273
82.60
82.60
82.60
21.50
21.50
21.50
0.0000
0.0000
0.0000
0.00
0.00
0.00
100%
100%
100%
41.8684 EHS A
B
C
3/8
3/8
3/8
2310.00
2310.00
2310.00
15%
15%
15%
23000
23000
23000
0.273
0.273
0.273
46.86
46.86
46.86
21.50
21.50
21.50
0.0000
0.0000
0.0000
0.00
0.00
0.00
100%
100%
100%
102 EHS A
B
C
3/8
3/8
3/8
2310.00
2310.00
2310.00
15%
15%
15%
23000
23000
23000
0.273
0.273
0.273
104.07
104.07
104.07
21.50
21.50
21.50
0.0000
0.0000
0.0000
0.00
0.00
0.00
100%
100%
100%
Guy Data(cont’d)
Guy
Elevation
ft
Mount
Type
Torque-Arm
Spread
ft
Torque-Arm
Leg Angle
°
Torque-Arm
Style
Torque-Arm
Grade
Torque-Arm
Type
Torque-Arm Size
79.9254 Corner
41.8684 Corner
102 Corner
Guy Data (cont’d)
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 8
tnxTower Report - version 8.1.1.0
Guy
Elevation
ft
Diagonal
Grade
Diagonal
Type
Upper Diagonal
Size
Lower Diagonal
Size
Is
Strap.
Pull-Off
Grade
Pull-Off Type Pull-Off Size
79.93 A572-50
(50 ksi)
Solid Round No A36
(36 ksi)
Flat Bar 2x3/8
41.87 A572-50
(50 ksi)
Solid Round No A36
(36 ksi)
Flat Bar 2x3/8
102.00 A572-50
(50 ksi)
Solid Round No A36
(36 ksi)
Flat Bar 2x3/8
Guy Data (cont’d)
Guy
Elevation
ft
Cable
Weight
A
lb
Cable
Weight
B
lb
Cable
Weight
C
lb
Cable
Weight
D
lb
Tower
Intercept
A
ft
Tower
Intercept
B
ft
Tower
Intercept
C
ft
Tower
Intercept
D
ft
79.9254 22.55 22.55 22.55 0.40
1.1
sec/pulse
0.40
1.1
sec/pulse
0.40
1.1 sec/pulse
41.8684 12.79 12.79 12.79 0.13
0.6
sec/pulse
0.13
0.6
sec/pulse
0.13
0.6 sec/pulse
102 28.41 28.41 28.41 0.64
1.4
sec/pulse
0.64
1.4
sec/pulse
0.64
1.4 sec/pulse
Guy Data (cont’d)
Torque Arm Pull Off Diagonal
Guy
Elevation
ft
Calc
K
Single
Angles
Calc
K
Solid
Rounds
Kx Ky Kx Ky Kx Ky
79.9254 No No 1 1 1 1
41.8684 No No 1 1 1 1
102 No No 1 1 1 1
Guy Data (cont’d)
Torque-Arm Pull Off Diagonal
Guy
Elevation
ft
Bolt Size
in
Number Net Width
Deduct
in
U
Bolt Size
in
Number Net Width
Deduct
in
U
Bolt Size
in
Number Net Width
Deduct
in
U
79.9254 0.6250
A325N
0 0.0000 0.75 0.6250
A325N
0 0.0000 0.75 0.6250
A325N
0 0.0000 0.75
41.8684 0.6250
A325N
0 0.0000 0.75 0.6250
A325N
0 0.0000 0.75 0.6250
A325N
0 0.0000 0.75
102 0.6250
A325N
0 0.0000 0.75 0.6250
A325N
0 0.0000 0.75 0.6250
A325N
0 0.0000 0.75
Guy Pressures
Guy
Elevation
ft
Guy
Location
z
ft
qz
psf
qz
Ice
psf
Ice
Thickness
in
79.9254 A
B
39.96
39.96
40
40
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 9
tnxTower Report - version 8.1.1.0
Guy
Elevation
ft
Guy
Location
z
ft
qz
psf
qz
Ice
psf
Ice
Thickness
in
C 39.96 40
41.8684 A
B
C
20.93
20.93
20.93
35
35
35
102 A
B
C
51.00
51.00
51.00
42
42
42
Guy-Tensioning Information
Temperature At Time Of Tensioning
0 F
20 F
40 F
60 F
80 F
100 F
120 F
Guy
Elevation
ft
H
ft
V
ft
Initial
Tension
lb
Intercept
ft
Initial
Tension
lb
Intercept
ft
Initial
Tension
lb
Intercept
ft
Initial
Tension
lb
Intercept
ft
Initial
Tension
lb
Intercept
ft
Initial
Tension
lb
Intercept
ft
Initial
Tension
lb
Intercept
ft
79.9254 A
B
C
21.25
21.25
21.25
79.93
79.93
79.93
2357
2357
2357
0.39
0.39
0.39
2341
2341
2341
0.40
0.40
0.40
2326
2326
2326
0.40
0.40
0.40
2310
2310
2310
0.40
0.40
0.40
2294
2294
2294
0.40
0.40
0.40
2279
2279
2279
0.41
0.41
0.41
2263
2263
2263
0.41
0.41
0.41
41.8684 A
B
C
21.17
21.17
21.17
41.87
41.87
41.87
2455
2455
2455
0.12
0.12
0.12
2407
2407
2407
0.12
0.12
0.12
2358
2358
2358
0.13
0.13
0.13
2310
2310
2310
0.13
0.13
0.13
2262
2262
2262
0.13
0.13
0.13
2214
2214
2214
0.14
0.14
0.14
2165
2165
2165
0.14
0.14
0.14
102 A
B
C
21.29
21.29
21.29
102.00
102.00
102.00
2340
2340
2340
0.63
0.63
0.63
2330
2330
2330
0.63
0.63
0.63
2320
2320
2320
0.63
0.63
0.63
2310
2310
2310
0.64
0.64
0.64
2300
2300
2300
0.64
0.64
0.64
2290
2290
2290
0.64
0.64
0.64
2280
2280
2280
0.65
0.65
0.65
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Sector Exclude
From
Torque
Calculation
Componen
t
Type
Placement
ft
Total
Number
Number
Per Row
Start/En
d
Position
Width or
Diamete
r
in
Perimete
r
in
Weight
plf
1/2 C No Surface Ar
(CaAa)
85.00 -
0.00
18 9 0.000
0.000
1.0300 0.33
Feed Line/Linear Appurtenances Section Areas
Tower
Sectio
n
Tower
Elevation
ft
Face AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
lb
L1 102.00-82.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
2.781
0.000
0.000
0.000
0.00
0.00
17.82
L2 82.00-62.29 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
18.270
0.000
0.000
0.000
0.00
0.00
117.07
L3 62.29-42.88 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
17.999
0.000
0.000
0.000
0.00
0.00
115.34
L4 42.88-23.75 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
17.729
0.000
0.000
0.000
0.00
0.00
113.60
L5 23.75-4.92 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
17.458
0.000
0.000
0.000
0.00
0.00
111.87
L6 4.92-0.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
4.558
0.000
0.000
0.000
0.00
0.00
29.21
Feed Line Center of Pressure
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 10
tnxTower Report - version 8.1.1.0
Section Elevation
ft
CPX
in
CPZ
in
CPX
Ice
in
CPZ
Ice
in
L1 102.00-82.00 0.0000 0.0000 0.0000 0.0000
L2 82.00-62.29 0.0000 0.0000 0.0000 0.0000
L3 62.29-42.88 0.0000 0.0000 0.0000 0.0000
L4 42.88-23.75 0.0000 0.0000 0.0000 0.0000
L5 23.75-4.92 0.0000 0.0000 0.0000 0.0000
L6 4.92-0.00 0.0000 0.0000 0.0000 0.0000
Note: For pole sections, center of pressure calculations do not consider feed line shielding.
Shielding Factor Ka
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment
Elev.
Ka
No Ice
Ka
Ice
L1 1 1/2 82.00 -
85.00
1.0000 1.0000
L2 1 1/2 62.29 -
82.00
1.0000 1.0000
L3 1 1/2 42.88 -
62.29
1.0000 1.0000
L4 1 1/2 23.75 -
42.88
1.0000 1.0000
L5 1 1/2 4.92 - 23.75 1.0000 1.0000
L6 1 1/2 0.00 - 4.92 1.0000 1.0000
Discrete Tower Loads
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustmen
t
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
lb
NHH-65B-R2B A From Leg 1.00
0.00
0.00
0.0000 102.00 No Ice 4.16 2.49 43.70
NHH-65B-R2B B From Leg 1.00
0.00
0.00
0.0000 102.00 No Ice 4.16 2.49 43.70
NHH-65B-R2B C From Leg 1.00
0.00
0.00
0.0000 102.00 No Ice 4.16 2.49 43.70
Tower Pressures - No Ice
GH = 1.100
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 11
tnxTower Report - version 8.1.1.0
Section
Elevation
ft
z
ft
KZ
qz
psf
AG
ft2
F
a
c
e
AF
ft2
AR
ft2
Aleg
ft2
Leg
%
CAAA
In
Face
ft2
CAAA
Out
Face
ft2
L1 102.00-
82.00
92.00 1.244 48 8.333 A
B
C
8.333
8.333
8.333
0.000
0.000
0.000
8.333 100.00
100.00
100.00
0.000
0.000
2.781
0.000
0.000
0.000
L2 82.00-
62.29
72.15 1.182 45 9.854 A
B
C
9.854
9.854
9.854
0.000
0.000
0.000
9.854 100.00
100.00
100.00
0.000
0.000
18.270
0.000
0.000
0.000
L3 62.29-
42.88
52.58 1.105 42 11.326 A
B
C
11.326
11.326
11.326
0.000
0.000
0.000
11.326 100.00
100.00
100.00
0.000
0.000
17.999
0.000
0.000
0.000
L4 42.88-
23.75
33.31 1.004 39 12.750 A
B
C
12.750
12.750
12.750
0.000
0.000
0.000
12.750 100.00
100.00
100.00
0.000
0.000
17.729
0.000
0.000
0.000
L5 23.75-4.92 14.33 0.85 33 14.125 A
B
C
14.125
14.125
14.125
0.000
0.000
0.000
14.125 100.00
100.00
100.00
0.000
0.000
17.458
0.000
0.000
0.000
L6 4.92-0.00 2.46 0.85 33 4.098 A
B
C
4.098
4.098
4.098
0.000
0.000
0.000
4.098 100.00
100.00
100.00
0.000
0.000
4.558
0.000
0.000
0.000
Tower Pressure - Service
GH = 1.100
Section
Elevation
ft
z
ft
KZ
qz
psf
AG
ft2
F
a
c
e
AF
ft2
AR
ft2
Aleg
ft2
Leg
%
CAAA
In
Face
ft2
CAAA
Out
Face
ft2
L1 102.00-
82.00
92.00 1.244 10 8.333 A
B
C
8.333
8.333
8.333
0.000
0.000
0.000
8.333 100.00
100.00
100.00
0.000
0.000
2.781
0.000
0.000
0.000
L2 82.00-
62.29
72.15 1.182 9 9.854 A
B
C
9.854
9.854
9.854
0.000
0.000
0.000
9.854 100.00
100.00
100.00
0.000
0.000
18.270
0.000
0.000
0.000
L3 62.29-
42.88
52.58 1.105 9 11.326 A
B
C
11.326
11.326
11.326
0.000
0.000
0.000
11.326 100.00
100.00
100.00
0.000
0.000
17.999
0.000
0.000
0.000
L4 42.88-
23.75
33.31 1.004 8 12.750 A
B
C
12.750
12.750
12.750
0.000
0.000
0.000
12.750 100.00
100.00
100.00
0.000
0.000
17.729
0.000
0.000
0.000
L5 23.75-4.92 14.33 0.85 7 14.125 A
B
C
14.125
14.125
14.125
0.000
0.000
0.000
14.125 100.00
100.00
100.00
0.000
0.000
17.458
0.000
0.000
0.000
L6 4.92-0.00 2.46 0.85 7 4.098 A
B
C
4.098
4.098
4.098
0.000
0.000
0.000
4.098 100.00
100.00
100.00
0.000
0.000
4.558
0.000
0.000
0.000
Tower Forces - No Ice - Wind Normal To Face
Section
Elevation
ft
Add
Weight
lb
Self
Weight
lb
F
a
c
e
e CF
qz
psf
DF
DR
AE
ft2
F
lb
w
plf
Ctrl.
Face
L1 102.00-
82.00
17.82 312.38 A
B
C
1
1
1
2.1
2.1
2.1
48 1
1
1
1
1
1
16.667
16.667
16.667
920.17* 46.01 C
L2 82.00-
62.29
117.07 351.41 A
B
C
1
1
1
2.1
2.1
2.1
45 1
1
1
1
1
1
19.708
19.708
19.708
1033.81* 52.46 C
L3 62.29-
42.88
115.34 407.66 A
B
C
1
1
1
2.1
2.1
2.1
42 1
1
1
1
1
1
22.653
22.653
22.653
1111.72* 57.26 C
L4 42.88- 113.60 462.05 A 1 2.1 39 1 1 25.500 1136.78
* 59.44 C
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 12
tnxTower Report - version 8.1.1.0
Section
Elevation
ft
Add
Weight
lb
Self
Weight
lb
F
a
c
e
e CF
qz
psf
DF
DR
AE
ft2
F
lb
w
plf
Ctrl.
Face
23.75 B
C
1
1
2.1
2.1
1
1
1
1
25.500
25.500
L5 23.75-
4.92
111.87 514.60 A
B
C
1
1
1
2.1
2.1
2.1
33 1
1
1
1
1
1
28.249
28.249
28.249
1066.03* 56.60 C
L6 4.92-0.00 29.21 149.91 A
B
C
1
1
1
2.1
2.1
2.1
33 1
1
1
1
1
1
8.195
8.195
8.195
309.25* 62.89 C
Sum Weight: 504.90 2198.01 *2.1Ag
limit
5577.75
Tower Forces - No Ice - Wind 45 To Face
Section
Elevation
ft
Add
Weight
lb
Self
Weight
lb
F
a
c
e
e CF
qz
psf
DF
DR
AE
ft2
F
lb
w
plf
Ctrl.
Face
L1 102.00-
82.00
17.82 312.38 A
B
C
1
1
1
2.1
2.1
2.1
48 1.2
1.2
1.2
1.2
1.2
1.2
20.000
20.000
20.000
920.17* 46.01 C
L2 82.00-
62.29
117.07 351.41 A
B
C
1
1
1
2.1
2.1
2.1
45 1.2
1.2
1.2
1.2
1.2
1.2
23.650
23.650
23.650
1033.81* 52.46 C
L3 62.29-
42.88
115.34 407.66 A
B
C
1
1
1
2.1
2.1
2.1
42 1.2
1.2
1.2
1.2
1.2
1.2
27.183
27.183
27.183
1111.72* 57.26 C
L4 42.88-
23.75
113.60 462.05 A
B
C
1
1
1
2.1
2.1
2.1
39 1.2
1.2
1.2
1.2
1.2
1.2
30.600
30.600
30.600
1136.78* 59.44 C
L5 23.75-
4.92
111.87 514.60 A
B
C
1
1
1
2.1
2.1
2.1
33 1.2
1.2
1.2
1.2
1.2
1.2
33.899
33.899
33.899
1066.03* 56.60 C
L6 4.92-0.00 29.21 149.91 A
B
C
1
1
1
2.1
2.1
2.1
33 1.2
1.2
1.2
1.2
1.2
1.2
9.834
9.834
9.834
309.25* 62.89 C
Sum Weight: 504.90 2198.01 *2.1Ag
limit
5577.75
Tower Forces - Service - Wind Normal To Face
Section
Elevation
ft
Add
Weight
lb
Self
Weight
lb
F
a
c
e
e CF
qz
psf
DF
DR
AE
ft2
F
lb
w
plf
Ctrl.
Face
L1 102.00-
82.00
17.82 312.38 A
B
C
1
1
1
2.1
2.1
2.1
10 1
1
1
1
1
1
16.667
16.667
16.667
187.48* 9.37 C
L2 82.00-
62.29
117.07 351.41 A
B
C
1
1
1
2.1
2.1
2.1
9 1
1
1
1
1
1
19.708
19.708
19.708
210.64* 10.69 C
L3 62.29-
42.88
115.34 407.66 A
B
C
1
1
1
2.1
2.1
2.1
9 1
1
1
1
1
1
22.653
22.653
22.653
226.51* 11.67 C
L4 42.88-
23.75
113.60 462.05 A
B
C
1
1
1
2.1
2.1
2.1
8 1
1
1
1
1
1
25.500
25.500
25.500
231.62* 12.11 C
L5 23.75- 111.87 514.60 A 1 2.1 7 1 1 28.249 217.20
* 11.53 C
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 13
tnxTower Report - version 8.1.1.0
Section
Elevation
ft
Add
Weight
lb
Self
Weight
lb
F
a
c
e
e CF
qz
psf
DF
DR
AE
ft2
F
lb
w
plf
Ctrl.
Face
4.92 B
C
1
1
2.1
2.1
1
1
1
1
28.249
28.249
L6 4.92-0.00 29.21 149.91 A
B
C
1
1
1
2.1
2.1
2.1
7 1
1
1
1
1
1
8.195
8.195
8.195
63.01* 12.81 C
Sum Weight: 504.90 2198.01 *2.1Ag
limit
1136.46
Tower Forces - Service - Wind 45 To Face
Section
Elevation
ft
Add
Weight
lb
Self
Weight
lb
F
a
c
e
e CF
qz
psf
DF
DR
AE
ft2
F
lb
w
plf
Ctrl.
Face
L1 102.00-
82.00
17.82 312.38 A
B
C
1
1
1
2.1
2.1
2.1
10 1.2
1.2
1.2
1.2
1.2
1.2
20.000
20.000
20.000
187.48* 9.37 C
L2 82.00-
62.29
117.07 351.41 A
B
C
1
1
1
2.1
2.1
2.1
9 1.2
1.2
1.2
1.2
1.2
1.2
23.650
23.650
23.650
210.64* 10.69 C
L3 62.29-
42.88
115.34 407.66 A
B
C
1
1
1
2.1
2.1
2.1
9 1.2
1.2
1.2
1.2
1.2
1.2
27.183
27.183
27.183
226.51* 11.67 C
L4 42.88-
23.75
113.60 462.05 A
B
C
1
1
1
2.1
2.1
2.1
8 1.2
1.2
1.2
1.2
1.2
1.2
30.600
30.600
30.600
231.62* 12.11 C
L5 23.75-
4.92
111.87 514.60 A
B
C
1
1
1
2.1
2.1
2.1
7 1.2
1.2
1.2
1.2
1.2
1.2
33.899
33.899
33.899
217.20* 11.53 C
L6 4.92-0.00 29.21 149.91 A
B
C
1
1
1
2.1
2.1
2.1
7 1.2
1.2
1.2
1.2
1.2
1.2
9.834
9.834
9.834
63.01* 12.81 C
Sum Weight: 504.90 2198.01 *2.1Ag
limit
1136.46
Force Totals (Does not include forces on guys)
Load
Case
Vertical
Forces
lb
Sum of
Forces
X
lb
Sum of
Forces
Z
lb
Sum of
Torques
lb-ft
Leg Weight 2198.01
Bracing Weight 0.00
Total Member Self-Weight 2198.01
Guy Weight 191.25
Total Weight 3025.26
Wind 0 deg - No Ice 0.00 -6060.16 0.00
Wind 30 deg - No Ice 3030.08 -5248.26 0.00
Wind 60 deg - No Ice 5248.26 -3030.08 0.00
Wind 90 deg - No Ice 6060.16 0.00 0.00
Wind 120 deg - No Ice 5248.26 3030.08 0.00
Wind 150 deg - No Ice 3030.08 5248.26 0.00
Wind 180 deg - No Ice 0.00 6060.16 0.00
Wind 210 deg - No Ice -3030.08 5248.26 0.00
Wind 240 deg - No Ice -5248.26 3030.08 0.00
Wind 270 deg - No Ice -6060.16 0.00 0.00
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 14
tnxTower Report - version 8.1.1.0
Load
Case
Vertical
Forces
lb
Sum of
Forces
X
lb
Sum of
Forces
Z
lb
Sum of
Torques
lb-ft
Wind 300 deg - No Ice -5248.26 -3030.08 0.00
Wind 330 deg - No Ice -3030.08 -5248.26 0.00
Total Weight 3025.26
Wind 0 deg - Service 0.00 -1234.75 0.00
Wind 30 deg - Service 617.38 -1069.33 0.00
Wind 60 deg - Service 1069.33 -617.38 0.00
Wind 90 deg - Service 1234.75 0.00 0.00
Wind 120 deg - Service 1069.33 617.38 0.00
Wind 150 deg - Service 617.38 1069.33 0.00
Wind 180 deg - Service 0.00 1234.75 0.00
Wind 210 deg - Service -617.38 1069.33 0.00
Wind 240 deg - Service -1069.33 617.38 0.00
Wind 270 deg - Service -1234.75 0.00 0.00
Wind 300 deg - Service -1069.33 -617.38 0.00
Wind 330 deg - Service -617.38 -1069.33 0.00
Load Combinations
Comb.
No.
Description
1 Dead Only
2 1.2 Dead+1.0 Wind 0 deg - No Ice+1.0 Guy
3 1.2 Dead+1.0 Wind 30 deg - No Ice+1.0 Guy
4 1.2 Dead+1.0 Wind 60 deg - No Ice+1.0 Guy
5 1.2 Dead+1.0 Wind 90 deg - No Ice+1.0 Guy
6 1.2 Dead+1.0 Wind 120 deg - No Ice+1.0 Guy
7 1.2 Dead+1.0 Wind 150 deg - No Ice+1.0 Guy
8 1.2 Dead+1.0 Wind 180 deg - No Ice+1.0 Guy
9 1.2 Dead+1.0 Wind 210 deg - No Ice+1.0 Guy
10 1.2 Dead+1.0 Wind 240 deg - No Ice+1.0 Guy
11 1.2 Dead+1.0 Wind 270 deg - No Ice+1.0 Guy
12 1.2 Dead+1.0 Wind 300 deg - No Ice+1.0 Guy
13 1.2 Dead+1.0 Wind 330 deg - No Ice+1.0 Guy
14 Dead+Wind 0 deg - Service+Guy
15 Dead+Wind 30 deg - Service+Guy
16 Dead+Wind 60 deg - Service+Guy
17 Dead+Wind 90 deg - Service+Guy
18 Dead+Wind 120 deg - Service+Guy
19 Dead+Wind 150 deg - Service+Guy
20 Dead+Wind 180 deg - Service+Guy
21 Dead+Wind 210 deg - Service+Guy
22 Dead+Wind 240 deg - Service+Guy
23 Dead+Wind 270 deg - Service+Guy
24 Dead+Wind 300 deg - Service+Guy
25 Dead+Wind 330 deg - Service+Guy
Maximum Member Forces
Sectio
n
No.
Elevation
ft
Component
Type
Condition Gov.
Load
Comb.
Axial
lb
Major Axis
Moment
lb-ft
Minor Axis
Moment
lb-ft
L1 102 - 82 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 10 -14134.76 1426.81 -812.82
Max. Mx 11 -12112.62 -2836.53 168.51
Max. My 2 -13883.45 -0.00 -2777.37
Max. Vy 11 905.65 -1163.79 60.87
Max. Vx 2 891.87 -0.00 -1260.84
Max. Torque 7 4.21
Guy A Bottom Tension 7 7183.53
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 15
tnxTower Report - version 8.1.1.0
Sectio
n
No.
Elevation
ft
Component
Type
Condition Gov.
Load
Comb.
Axial
lb
Major Axis
Moment
lb-ft
Minor Axis
Moment
lb-ft
Top Tension 7 7208.05
Top Cable Vert 7 7052.41
Top Cable Norm 7 1488.83
Top Cable Tan 7 53.71
Bot Cable Vert 7 -6993.10
Bot Cable Norm 7 1636.84
Bot Cable Tan 7 142.89
Guy B Bottom Tension 11 7180.41
Top Tension 11 7204.92
Top Cable Vert 11 7049.37
Top Cable Norm 11 1488.09
Top Cable Tan 11 53.70
Bot Cable Vert 11 -6990.07
Bot Cable Norm 11 1636.10
Bot Cable Tan 11 142.87
Guy C Bottom Tension 5 7180.41
Top Tension 5 7204.92
Top Cable Vert 5 7049.37
Top Cable Norm 5 1488.09
Top Cable Tan 5 53.70
Bot Cable Vert 5 -6990.07
Bot Cable Norm 5 1636.10
Bot Cable Tan 5 142.87
L2 82 - 62.2917 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 10 -28534.02 1333.27 -769.87
Max. Mx 4 -19406.54 3245.65 -1869.83
Max. My 8 -19415.02 0.00 3752.48
Max. Vy 11 -737.57 2632.95 226.73
Max. Vx 8 -767.22 0.00 -1362.50
Max. Torque 7 13.99
Guy A Bottom Tension 7 8078.71
Top Tension 7 8098.28
Top Cable Vert 7 7815.81
Top Cable Norm 7 2119.28
Top Cable Tan 7 62.08
Bot Cable Vert 7 -7764.62
Bot Cable Norm 7 2227.03
Bot Cable Tan 7 128.69
Guy B Bottom Tension 11 8071.27
Top Tension 11 8090.84
Top Cable Vert 11 7808.68
Top Cable Norm 11 2117.16
Top Cable Tan 11 62.08
Bot Cable Vert 11 -7757.49
Bot Cable Norm 11 2224.91
Bot Cable Tan 11 128.68
Guy C Bottom Tension 5 8071.27
Top Tension 5 8090.84
Top Cable Vert 5 7808.68
Top Cable Norm 5 2117.16
Top Cable Tan 5 62.08
Bot Cable Vert 5 -7757.49
Bot Cable Norm 5 2224.91
Bot Cable Tan 5 128.68
L3 62.2917 -
42.875
Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 10 -29139.63 15724.59 -9092.98
Max. Mx 11 -25706.16 16354.96 -1892.45
Max. My 2 -29102.21 0.00 18121.34
Max. Vy 5 1243.42 -16354.96 -1892.45
Max. Vx 8 1294.72 0.00 -13659.22
Max. Torque 7 13.99
L4 42.875 -
23.75
Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 10 -39072.66 5156.03 -2982.19
Max. Mx 11 -25743.17 17599.20 -1856.14
Max. My 2 -29139.03 0.00 19211.40
Max. Vy 11 -1266.33 17599.20 -1856.14
Max. Vx 8 1330.46 0.00 -14971.18
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 16
tnxTower Report - version 8.1.1.0
Sectio
n
No.
Elevation
ft
Component
Type
Condition Gov.
Load
Comb.
Axial
lb
Major Axis
Moment
lb-ft
Minor Axis
Moment
lb-ft
Max. Torque 7 17.34
Guy A Bottom Tension 9 6325.38
Top Tension 9 6336.44
Top Cable Vert 9 5654.71
Top Cable Norm 9 2859.12
Top Cable Tan 9 9.76
Bot Cable Vert 9 -5620.21
Bot Cable Norm 9 2902.07
Bot Cable Tan 9 40.90
Guy B Bottom Tension 11 6322.98
Top Tension 11 6334.04
Top Cable Vert 11 5652.58
Top Cable Norm 11 2858.01
Top Cable Tan 11 9.77
Bot Cable Vert 11 -5618.08
Bot Cable Norm 11 2900.96
Bot Cable Tan 11 40.90
Guy C Bottom Tension 5 6322.98
Top Tension 5 6334.04
Top Cable Vert 5 5652.58
Top Cable Norm 5 2858.01
Top Cable Tan 5 9.77
Bot Cable Vert 5 -5618.08
Bot Cable Norm 5 2900.96
Bot Cable Tan 5 40.90
L5 23.75 -
4.917
Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 10 -39820.27 6877.25 -3966.79
Max. Mx 5 -35884.92 -8494.86 -409.25
Max. My 8 -28610.66 0.00 -8267.54
Max. Vy 12 -708.44 7161.89 4137.42
Max. Vx 8 814.34 0.00 -8267.54
Max. Torque 7 17.31
L6 4.917 - 0 Pole Max Tension 1 0.00 0.00 0.00
Max. Compression 10 -40035.95 9673.33 -5580.31
Max. Mx 5 -36100.86 -12301.59 18.01
Max. My 8 -28826.91 0.00 -12903.84
Max. Vy 12 -933.00 11176.91 6457.98
Max. Vx 8 1073.63 0.00 -12903.84
Max. Torque 7 17.31
Maximum Reactions
Location Condition Gov.
Load
Comb.
Vertical
lb
Horizontal, X
lb
Horizontal, Z
lb
Mast Max. Vert 10 40036.13 672.67 -384.49
Max. Hx 12 28817.28 926.26 539.00
Max. Hz 2 40000.24 0.00 781.77
Max. Mx 2 11199.11 0.00 781.77
Max. Mz 5 12301.59 -894.78 91.01
Max. Torsion 7 17.32 -371.84 -814.67
Min. Vert 1 22682.80 0.00 2.95
Min. Hx 4 28817.28 -926.26 539.00
Min. Hz 8 28827.20 0.00 -1065.85
Min. Mx 8 -12903.84 0.00 -1065.85
Min. Mz 11 -12301.59 894.78 91.01
Min. Torsion 9 -17.32 371.84 -814.67
Guy C @ 21.5 ft
Elev 0 ft
Azimuth 240 deg
Max. Vert 10 -1074.84 -93.45 53.95
Max. Hx 10 -1074.84 -93.45 53.95
Max. Hz 3 -20354.67 -5697.36 3649.26
Min. Vert 5 -20365.63 -6012.27 3110.38
Min. Hx 5 -20365.63 -6012.27 3110.38
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 17
tnxTower Report - version 8.1.1.0
Location Condition Gov.
Load
Comb.
Vertical
lb
Horizontal, X
lb
Horizontal, Z
lb
Min. Hz 9 -1282.62 -214.19 9.85
Guy B @ 21.5 ft
Elev 0 ft
Azimuth 120 deg
Max. Vert 6 -1074.84 93.45 53.95
Max. Hx 11 -20365.63 6012.27 3110.38
Max. Hz 13 -20354.67 5697.36 3649.26
Min. Vert 11 -20365.63 6012.27 3110.38
Min. Hx 6 -1074.84 93.45 53.95
Min. Hz 7 -1282.62 214.19 9.85
Guy A @ 21.5 ft
Elev 0 ft
Azimuth 0 deg
Max. Vert 2 -1076.21 0.00 -108.23
Max. Hx 10 -17689.01 461.36 -5685.95
Max. Hz 2 -1076.21 0.00 -108.23
Min. Vert 9 -20377.93 312.47 -6765.93
Min. Hx 6 -17689.01 -461.36 -5685.95
Min. Hz 9 -20377.93 312.47 -6765.93
Tower Mast Reaction Summary
Load
Combination
Vertical
lb
Shearx
lb
Shearz
lb
Overturning
Moment, Mx
lb-ft
Overturning
Moment, Mz
lb-ft
Torque
lb-ft
Dead Only 22682.80 0.00 -2.95 1.33 0.00 0.00
1.2 Dead+1.0 Wind 0 deg -
No Ice+1.0 Guy
40000.24 -0.00 -781.77 -11199.11 0.00 0.00
1.2 Dead+1.0 Wind 30 deg -
No Ice+1.0 Guy
36068.72 523.02 -736.23 -10662.02 -6165.07 -16.75
1.2 Dead+1.0 Wind 60 deg -
No Ice+1.0 Guy
28817.28 926.26 -539.00 -6457.98 -11176.91 0.08
1.2 Dead+1.0 Wind 90 deg -
No Ice+1.0 Guy
36101.10 894.78 -91.01 -18.01 -12301.59 16.70
1.2 Dead+1.0 Wind 120 deg
- No Ice+1.0 Guy
40036.13 672.67 384.49 5580.31 -9673.33 -0.63
1.2 Dead+1.0 Wind 150 deg
- No Ice+1.0 Guy
36101.37 371.84 814.67 10657.25 -6137.36 -17.32
1.2 Dead+1.0 Wind 180 deg
- No Ice+1.0 Guy
28827.20 0.00 1065.85 12903.84 0.00 0.00
1.2 Dead+1.0 Wind 210 deg
- No Ice+1.0 Guy
36101.37 -371.84 814.67 10657.25 6137.36 17.32
1.2 Dead+1.0 Wind 240 deg
- No Ice+1.0 Guy
40036.13 -672.67 384.49 5580.31 9673.33 0.63
1.2 Dead+1.0 Wind 270 deg
- No Ice+1.0 Guy
36101.10 -894.78 -91.01 -18.01 12301.59 -16.70
1.2 Dead+1.0 Wind 300 deg
- No Ice+1.0 Guy
28817.28 -926.26 -539.00 -6457.98 11176.91 -0.08
1.2 Dead+1.0 Wind 330 deg
- No Ice+1.0 Guy
36068.72 -523.02 -736.23 -10662.02 6165.07 16.75
Dead+Wind 0 deg -
Service+Guy
22759.92 -0.00 -239.79 -2789.44 0.00 0.00
Dead+Wind 30 deg -
Service+Guy
22760.69 118.41 -208.08 -2416.56 -1397.26 0.33
Dead+Wind 60 deg -
Service+Guy
22761.41 205.07 -121.46 -1397.09 -2418.84 -0.00
Dead+Wind 90 deg -
Service+Guy
22760.68 236.75 -3.10 -2.64 -2790.92 -0.33
Dead+Wind 120 deg -
Service+Guy
22759.89 205.01 115.30 1393.87 -2415.21 -0.00
Dead+Wind 150 deg -
Service+Guy
22760.64 118.34 201.99 2417.50 -1393.66 0.32
Dead+Wind 180 deg -
Service+Guy
22761.36 0.00 233.73 2792.49 0.00 0.00
Dead+Wind 210 deg -
Service+Guy
22760.64 -118.34 201.99 2417.50 1393.66 -0.32
Dead+Wind 240 deg - 22759.89 -205.01 115.30 1393.87 2415.21 0.00
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 18
tnxTower Report - version 8.1.1.0
Load
Combination
Vertical
lb
Shearx
lb
Shearz
lb
Overturning
Moment, Mx
lb-ft
Overturning
Moment, Mz
lb-ft
Torque
lb-ft
Service+Guy
Dead+Wind 270 deg -
Service+Guy
22760.68 -236.75 -3.10 -2.64 2790.92 0.33
Dead+Wind 300 deg -
Service+Guy
22761.41 -205.07 -121.46 -1397.09 2418.84 0.00
Dead+Wind 330 deg -
Service+Guy
22760.69 -118.41 -208.08 -2416.56 1397.26 -0.33
Solution Summary
Load
Comb.
Sum of Applied Forces Sum of Reactions
% Error PX
lb
PY
lb
PZ
lb
PX
lb
PY
lb
PZ
lb
1 0.00 -3025.24 0.00 0.00 3025.21 -0.01 0.001%
2 0.00 -3595.71 -7149.94 0.00 3595.69 7149.89 0.001%
3 3574.96 -3592.05 -6192.02 -3574.94 3592.04 6191.88 0.002%
4 6192.03 -3588.38 -3574.97 -6191.52 3588.37 3574.74 0.007%
5 7149.93 -3592.05 0.00 -7149.80 3592.04 0.05 0.002%
6 6192.03 -3595.71 3574.97 -6191.99 3595.69 -3574.95 0.001%
7 3574.96 -3592.05 6192.02 -3574.86 3592.04 -6191.93 0.002%
8 0.00 -3588.38 7149.94 0.00 3588.37 -7149.38 0.007%
9 -3574.96 -3592.05 6192.02 3574.86 3592.04 -6191.93 0.002%
10 -6192.03 -3595.71 3574.97 6191.99 3595.69 -3574.95 0.001%
11 -7149.93 -3592.05 0.00 7149.80 3592.04 0.05 0.002%
12 -6192.03 -3588.38 -3574.97 6191.52 3588.37 3574.74 0.007%
13 -3574.96 -3592.05 -6192.02 3574.94 3592.04 6191.88 0.002%
14 0.00 -3025.99 -1456.79 0.00 3025.99 1456.24 0.016%
15 728.39 -3025.24 -1261.62 -728.14 3025.24 1261.15 0.016%
16 1261.62 -3024.50 -728.40 -1261.17 3024.50 728.14 0.015%
17 1456.79 -3025.24 0.00 -1456.25 3025.24 0.01 0.016%
18 1261.62 -3025.99 728.40 -1261.14 3025.99 -728.12 0.017%
19 728.39 -3025.24 1261.62 -728.11 3025.24 -1261.16 0.016%
20 0.00 -3024.50 1456.79 0.00 3024.50 -1456.27 0.016%
21 -728.39 -3025.24 1261.62 728.11 3025.24 -1261.16 0.016%
22 -1261.62 -3025.99 728.40 1261.14 3025.99 -728.12 0.017%
23 -1456.79 -3025.24 0.00 1456.25 3025.24 0.01 0.016%
24 -1261.62 -3024.50 -728.40 1261.17 3024.50 728.14 0.015%
25 -728.39 -3025.24 -1261.62 728.14 3025.24 1261.15 0.016%
Non-Linear Convergence Results
Load
Combination
Converged? Number
of Cycles
Displacement
Tolerance
Force
Tolerance
1 Yes 6 0.00000001 0.00002098
2 Yes 51 0.00009871 0.00003082
3 Yes 35 0.00008147 0.00003285
4 Yes 18 0.00000001 0.00004429
5 Yes 35 0.00008259 0.00003328
6 Yes 52 0.00009132 0.00002837
7 Yes 35 0.00008269 0.00003331
8 Yes 18 0.00000001 0.00004458
9 Yes 35 0.00008269 0.00003331
10 Yes 52 0.00009132 0.00002837
11 Yes 35 0.00008259 0.00003328
12 Yes 18 0.00000001 0.00004429
13 Yes 35 0.00008147 0.00003285
14 Yes 13 0.00000001 0.00000988
15 Yes 13 0.00000001 0.00000962
16 Yes 13 0.00000001 0.00000938
17 Yes 13 0.00000001 0.00000969
18 Yes 13 0.00000001 0.00000995
19 Yes 13 0.00000001 0.00000971
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 19
tnxTower Report - version 8.1.1.0
20 Yes 13 0.00000001 0.00000948
21 Yes 13 0.00000001 0.00000971
22 Yes 13 0.00000001 0.00000995
23 Yes 13 0.00000001 0.00000969
24 Yes 13 0.00000001 0.00000938
25 Yes 13 0.00000001 0.00000962
Maximum Tower Deflections - Service Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
L1 102 - 82 2.381 20 0.0405 0.0002
L2 82 - 62.2917 1.966 20 0.1273 0.0001
L3 62.2917 - 42.875 1.371 20 0.2072 0.0001
L4 42.875 - 23.75 0.530 20 0.1421 0.0001
L5 23.75 - 4.917 0.196 20 0.0569 0.0000
L6 4.917 - 0 0.012 24 0.0224 0.0000
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
102.00 Guy 20 2.381 0.0405 0.0002 144904
79.93 Guy 20 1.917 0.1383 0.0001 25797
41.87 Guy 20 0.499 0.1366 0.0001 5527
Maximum Tower Deflections - Design Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
L1 102 - 82 30.805 10 1.8366 0.0036
L2 82 - 62.2917 21.608 6 2.3891 0.0015
L3 62.2917 - 42.875 11.979 10 2.3196 0.0038
L4 42.875 - 23.75 4.008 2 1.2674 0.0040
L5 23.75 - 4.917 1.060 13 0.3868 0.0016
L6 4.917 - 0 0.057 12 0.1040 0.0003
Critical Deflections and Radius of Curvature - Design Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
102.00 Guy 10 30.805 1.8366 0.0036 12432
79.93 Guy 6 20.612 2.4236 0.0016 3279
41.87 Guy 2 3.733 1.2073 0.0040 700
Guy Design Data
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 20
tnxTower Report - version 8.1.1.0
Section
No.
Elevation
ft
Size
Initial
Tension
lb
Breaking
Load
lb
Actual
Tu
lb
Allowable
Tn
lb
Required
S.F.
Actual
S.F.
L1 102.00 (A)
(15)
3/8 EHS 2310.00 15399.96 7208.05 9240.00 1.000 1.282
102.00 (B)
(14)
3/8 EHS 2310.00 15399.96 7204.92 9240.00 1.000 1.282
102.00 (C)
(13)
3/8 EHS 2310.00 15399.96 7204.92 9240.00 1.000 1.282
L2 79.93 (A) (9) 3/8 EHS 2310.00 15399.96 8098.28 9240.00 1.000 1.141
79.93 (B) (8) 3/8 EHS 2310.00 15399.96 8090.84 9240.00 1.000 1.142
79.93 (C) (7) 3/8 EHS 2310.00 15399.96 8090.84 9240.00 1.000 1.142
L4 41.87 (A) (12) 3/8 EHS 2310.00 15399.96 6336.44 9240.00 1.000 1.458
41.87 (B) (11) 3/8 EHS 2310.00 15399.96 6334.04 9240.00 1.000 1.459
41.87 (C) (10) 3/8 EHS 2310.00 15399.96 6334.04 9240.00 1.000 1.459
Compression Checks
Pole Design Data
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
lb
Pn
lb
Ratio
Pu
Pn
L1 102 - 82 (1) HSS5x5x1/4 20.00 22.07 138.1 4.5900 -13911.60 54410.10 0.256
L2 82 - 62.2917
(2)
HSS6x6x1/4 19.71 38.06 195.5 5.2400 -28534.00 30979.50 0.921 1
L3 62.2917 -
42.875 (3)
HSS7x7x1/4 19.42 38.06 166.4 6.1700 -29139.60 50368.70 0.579
L4 42.875 -
23.75 (4)
HSS8x8x1/4 19.13 41.87 159.2 7.1000 -38458.60 63273.80 0.608
L5 23.75 - 4.917
(5)
HSS9x9x1/4 18.83 41.87 141.0 8.0300 -39820.30 91286.00 0.436
L6 4.917 - 0 (6) HSS10x10x1/4 4.92 41.87 126.7 8.9600 -40035.90 126190.00 0.317
1 P u / Pn controls
Pole Bending Design Data
Section
No.
Elevation
ft
Size
Mux
lb-ft
Mnx
lb-ft
Ratio
Mux
Mnx
Muy
lb-ft
Mny
lb-ft
Ratio
Muy
Mny
L1 102 - 82 (1) HSS5x5x1/4 2786.35 34983.00 0.080 0.00 34983.00 0.000
L2 82 - 62.2917
(2)
HSS6x6x1/4 1539.58 49335.00 0.031 0.00 49335.00 0.000
L3 62.2917 -
42.875 (3)
HSS7x7x1/4 18164.42 68753.58 0.264 0.00 68753.58 0.000
L4 42.875 -
23.75 (4)
HSS8x8x1/4 17802.00 91468.33 0.195 0.00 91468.33 0.000
ti'
ti'
ti'
ti'
ti'
ti'
ti'
ti'
ti'
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 21
tnxTower Report - version 8.1.1.0
Section
No.
Elevation
ft
Size
Mux
lb-ft
Mnx
lb-ft
Ratio
Mux
Mnx
Muy
lb-ft
Mny
lb-ft
Ratio
Muy
Mny
L5 23.75 - 4.917
(5)
HSS9x9x1/4 7939.27 117300.00 0.068 0.00 117300.00 0.000
L6 4.917 - 0 (6) HSS10x10x1/4 11167.50 145935.00 0.077 0.00 145935.00 0.000
Pole Shear Design Data
Section
No.
Elevation
ft
Size
Actual
Vu
lb
Vn
lb
Ratio
Vu
Vn
Actual
Tu
lb-ft
Tn
lb-ft
Ratio
Tu
Tn
L1 102 - 82 (1) HSS5x5x1/4 34.40 114016.00 0.000 0.16 8280.00 0.000
L2 82 - 62.2917
(2)
HSS6x6x1/4 471.21 130162.00 0.004 0.50 31464.00 0.000
L3 62.2917 -
42.875 (3)
HSS7x7x1/4 1097.39 153263.00 0.007 0.50 43470.00 0.000
L4 42.875 -
23.75 (4)
HSS8x8x1/4 901.93 176364.00 0.005 0.63 57442.50 0.000
L5 23.75 - 4.917
(5)
HSS9x9x1/4 538.59 199465.00 0.003 0.63 73140.00 0.000
L6 4.917 - 0 (6) HSS10x10x1/4 784.21 222566.00 0.004 0.63 91080.00 0.000
Pole Interaction Design Data
Section
No.
Elevation
ft
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Ratio
Vu
Vn
Ratio
Tu
Tn
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
L1 102 - 82 (1) 0.256 0.080 0.000 0.000 0.000 0.298
1.000 4.8.1
L2 82 - 62.2917
(2)
0.921 0.031 0.000 0.004 0.000 0.921 1
1.000 4.8.1
L3 62.2917 -
42.875 (3)
0.579 0.264 0.000 0.007 0.000 0.749
1.000 4.8.1
L4 42.875 -
23.75 (4)
0.608 0.195 0.000 0.005 0.000 0.713
1.000 4.8.1
L5 23.75 - 4.917
(5)
0.436 0.068 0.000 0.003 0.000 0.448
1.000 4.8.1
L6 4.917 - 0 (6) 0.317 0.077 0.000 0.004 0.000 0.350
1.000 4.8.1
1 P u / Pn controls
Section Capacity Table
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
lb
øPallow
lb
%
Capacity
Pass
Fail
L1 102 - 82 Pole HSS5x5x1/4 1 -13911.60 54410.10 29.8 Pass
Guy A@102 3/8 15 7208.05 9240.00 78.0 Pass
Guy B@102 3/8 14 7204.92 9240.00 78.0 Pass
Guy C@102 3/8 13 7204.92 9240.00 78.0 Pass
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 22
tnxTower Report - version 8.1.1.0
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
lb
øPallow
lb
%
Capacity
Pass
Fail
L2 82 - 62.2917 Pole HSS6x6x1/4 2 -28534.00 30979.50 92.1 Pass
Guy A@79.9254 3/8 9 8098.28 9240.00 87.6 Pass
Guy B@79.9254 3/8 8 8090.84 9240.00 87.6 Pass
Guy C@79.9254 3/8 7 8090.84 9240.00 87.6 Pass
L3 62.2917 -
42.875
Pole HSS7x7x1/4 3 -29139.60 50368.70 74.9 Pass
L4 42.875 - 23.75 Pole HSS8x8x1/4 4 -38458.60 63273.80 71.3 Pass
Guy A@41.8684 3/8 12 6336.44 9240.00 68.6 Pass
Guy B@41.8684 3/8 11 6334.04 9240.00 68.6 Pass
Guy C@41.8684 3/8 10 6334.04 9240.00 68.6 Pass
L5 23.75 - 4.917 Pole HSS9x9x1/4 5 -39820.30 91286.00 44.8 Pass
L6 4.917 - 0 Pole HSS10x10x1/4 6 -40035.90 126190.00 35.0 Pass
Summary
Pole (L2) 92.1 Pass
Guy A (L2) 87.6 Pass
Guy B (L2) 87.6 Pass
Guy C (L2) 87.6 Pass
RATING = 92.1 Pass
August 03, 2021
102 Ft Cow/Colt Structural Analysis Selva Marina Relo
Project Number 21-5291 Page 23
tnxTower Report - version 8.1.1.0
APPENDIX B
BASE LEVEL DRAWING
Consulting Engineers
SMW Engineering
158 Business Center Drive
Birmingham, AL 35244
Phone: (205) 252-6985
FAX: (205) 795-7262
Job: Selva Marina Relo COW
Project: 21-5291
Client: Verizon Wireless Drawn by: Joe McAllister App'd:
Code: TIA-222-H Date: 08/03/21 Scale: NTS
Path: C:\Work from Home\21-5291 SELVA MARINA RELO TEMP\TNX Files\21-5291 Selva Marina Relo Temp.eri Dwg No. E-7
Feed Line Distribution Chart
0' - 102'
Round Flat App In Face App Out Face Truss Leg
Face A
82.00
62.29
79.9379.9379.93
42.88
23.75
4.92
0.00
102.00
El
e
v
a
t
i
o
n
(
f
t
)
Face B
85.00
Face C
82.00
62.29
79.9379.9379.93
42.88
23.75
4.92
0.00
102.00
85.00
(1
8
)
1
/
2
T-1
9/02/2021
NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATION
OF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGN
GROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVR
TELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANS
ARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BE
CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT
APPROVALS ARE OBTAINED.
610397
SELVA MARINA RELO - COW
469 11TH ST
ATLANTIC BEACH, FL 32233
CBVR PROJECT #: VZW.125.21
ISSUE FOR PERMIT / CONSTRUCTION0
TITLE PAGE
REAL STATE #: 172026-0000
JURISDICTION: CITY OF ATLANTIC BEACH
LATITUDE: 30° 20' 10.2199" NORTH
LONGITUDE: 81° 24' 19.85" WEST
ADDRESS: 469 11TH ST, ATLANTIC BEACH, FL 32233
COUNTY: DUVAL COUNTY
ARCHITECT/ ENGINEER:
CBVR / HUGH O. REILLY, PE
6505 N HIMES AVE,
TAMPA, FL 33634
PH: 305.439.6266
T-1 TITLE PAGE
GENERAL
ARCHITECTURAL/ CIVIL PLANS
C-1 OVERALL VIEW WITH AERIAL
C-3 PROPOSED TOWER ELEVATION
G-1 GENERAL NOTES
APPLICABLE CODES
LIST OF DRAWINGS
SITE INFORMATION
PROJECT SUMMARY
APPROVALS
CONTACT INFORMATIONLOCATION SKETCH
SITE DIRECTIONS
C-2 PROPOSED COW COMPOUND PLAN
APPLICANT :
VERIZON WIRELESS
7701 E TELECOM PKWY.
TEMPLE TERRACE, FL
33637
FROM I-95 N (TAMPA)
1. Get onto I-95 N toward Jacksonville.
2. Take exit 333 to merge onto FL-9B N toward Jax Beaches.
3. Merge onto I-295 N.
4. Take exit 48 toward FL-10 E/Atlantic Blvd.
5. Keep right at the fork, follow signs for Neptune Beach/Atlantic
Beach/Jacksonville Beach and merge onto FL-10 E/Atlantic Blvd.
6. Merge onto FL-10 E/Atlantic Blvd.
7. Use the right lane to take the ramp to Hanna Park/St Johns River Ferry.
8. Merge onto Mayport Rd.
9. Turn right onto Donner Rd.
10. Turn left onto Sandpiper Ln E.
11. Turn right onto Linkside Dr.
12. Turn right onto 11th St.
13. The site is on the right.
PROPERTY OWNER: _______________________________________
RF ENGINEER:_____________________________________________
CONSTRUCTION:___________________________________________
SITE ACQUISITION:_________________________________________
ZONING:__________________________________________________
NETWORK:________________________________________________
OPERATIONS:_____________________________________________
PROPERTY INFORMATION :
CITY OF ATLANTIC BEACH
469 11TH ST
ATLANTIC BEACH, FL 32233
C-5 CONSTRUCTION DETAILS
C-4 COW DETAILS
ELECTRICAL PLANS
E-1 GROUNDING DETAILS
PROPERTY OWNER :
CITY OF ATLANTIC BEACH
800 SEMINOLE RD
ATLANTIC BEACH, FL 32233
SITE NUMBER: 610397
SITE NAME: SELVA MARINA RELO - COW
STRUCTURE TYPE: COW
MARKET TYPE: JACKSONVILLE
PROJECT: TEMPORARY COW AT
ATLANTIC BEACH
FLORIDA BUILDING CODE 2020 (7TH EDITION)
WIND DESIGN CRITERIA
A. ASCE 7 - 16
ULTIMATE WIND SPEED1 =129 MPH
RISK CATEGORY = II
EXPOSURE = C
B. ANSI/ TIA-222-H
STRUCTURE CLASS = II
TOPOGRAPHIC CATEGORY = 1
- FLORIDA FIRE PREVENTION CODE - 2020 - 7TH EDITION
- NATIONAL ELECTRIC CODE (NFPA 70-2017)
- CITY AND OR COUNTY ORDINANCES
THE SCOPE OF WORK CONSISTS OF INSTALLING EQUIPMENT ON AN
EXISTING CONCRETE PAD AND ANTENNAS ON A TEMPORARY COW.
EQUIPMENT AREA:
·INSTALLATION OF PROPOSED COW
·INSTALLATION OF PROPOSED SLEEPERS W/ UNISTRUTS
·INSTALLATION OF PROPOSED (3) 4449 RRUs
·INSTALLATION OF PROPOSED (3) 8843 RRUs
·INSTALLATION OF PROPOSED (3) DBC-AP-4SF QUADPLEXERS
·INSTALLATION OF PROPOSED PRECAST CONCRETE SLAB
·INSTALLATION OF PROPOSED FIBER CABINET
TOWER RAD:
·INSTALLATION OF PROPOSED (3) ANTENNAS
·INSTALLATION OF PROPOSED (18) 1/2" COAX CABLES
SITE LOCATION
C-6 CONSTRUCTION DETAILS
Fllnt Cons1ruct1on
<~ Seftc@s
•.,. T ("'
1
~
\_
l
\ \
'; "
\ r, b
.;z ~~a•'f-
L1nkt1d•Dr -,~----,---!
;;( _______________ j \ i i ~ Pt ~=----
Know what's below
® Call before yo~ dig
BY
TELECOM DESIGN GROUP
6505 N HIMES AVE
TAMPA, FLORIDA 33614
(77 o) 853-1233
FL CA# 31014
Al
\\ Ill I/
IHI\\\\
~ ~ ~ .,., ---------
erizon✓
7701 E TE
TEMPLE TER~~~~MFPLKWY • 33637
G-1
9/02/2021
NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATION
OF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGN
GROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVR
TELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANS
ARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BE
CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT
APPROVALS ARE OBTAINED.
610397
SELVA MARINA RELO - COW
469 11TH ST
ATLANTIC BEACH, FL 32233
CBVR PROJECT #: VZW.125.21
ISSUE FOR PERMIT / CONSTRUCTION0
GENERAL NOTES
SITE WORK NOTES
1. FOR THE PURPOSES OF THESE CONSTRUCTION DRAWINGS. THE FOLLOWING DEFINITIONS SHALL APPLY:
OWNER - VERIZON WIRELESS
ENGINEER - CBVR TELECOM DESIGN GROUP
CONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION)
2. PRIOR TO SUBMITTING HIS BID. THE CONTRACTOR SHALL VISIT THE JOB SITE IN ORDER TO (1) VERIFY ALL EXISTING CONDITIONS, (2)
CONFIRM WHETHER ALL DIMENSIONS ARE AS SHOWN ON THE PLANS AND (3) CONFIRM WHETHER THE WORK MAY BE ACCOMPLISHED AS
SHOWN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER.
3. A 9-FOOT (MIN) HORIZONTAL CLEARANCE DISTANCE SHALL BE MAINTAINED FROM ALL EXISTING POWER LINES.
4. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY.
4. THE CONTRACTOR'S USE OF A CONSTRUCTION STAGING AREA SHALL BE COORDINATED WITH THE OWNER WELL IN ADVANCE OF THE
CONSTRUCTION START DATE.
5. LABOR, MATERIAL, TOOLS, EQUIPMENT, TRANSPORTATION AND TEMPORARY POWER SERVICES NECESSARY FOR AND INCIDENTAL TO
COMPLETION OF ALL WORK SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS AND/OR AS SPECIFIED HEREIN. LABOR AND MATERIALS
SHALL BE FURNISHED AS REQUIRED FOR COMPLETE SYSTEMS. INCLUDING ALL ELEMENTS OBVIOUSLY OR REASONABLY INCIDENTAL TO A
COMPLETE INSTALLATION, WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS.
6. FOR TASKS REQUIRED TO BE PERFORMED BUT NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. THE CONTRACTOR
SHALL NOT START WORK ON SUCH TASKS WITHOUT HAVING RECEIVED WRITTEN AUTHORIZATION FROM THE CONSTRUCTION MANAGER TO
PROCEED.
7. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS OTHERWISE
INDICATED BY DIMENSIONS OR DETAILS, EXACT EQUIPMENT LOCATIONS MAY BE MODIFIED AS REQUIRED BY ACTUAL FIELD CONDITIONS. IF
THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, CONTRACTOR SHALL PROPOSE AN ALTERNATIVE
INSTALLATION FOR APPROVAL BY THE ENGINEER AND THE CONSTRUCTION MANAGER.
8. THE CONTRACTOR SHALL OBTAIN, PAY FOR AND DELIVER ALL REQUIRED PERMITS. CERTIFICATES OF INSPECTION, INCLUDING UTILITY
CONNECTION FEES, ETC., REQUIRED BY THE AUTHORITIES HAVING JURISDICTION AND SHALL DELIVER SUCH DOCUMENTS TO THE OWNER
PRIOR TO FINAL ACCEPTANCE OF THE WORK.
9. THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED TO AREAS OF NEW CONSTRUCTION.
10. ALL NECESSARY PROVISIONS SHALL BE MADE TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, GALVANIZED SURFACES, ETC. AND
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO SAME RESULTING FROM THE CONSTRUCTION WORK. ALL DISTURBED AND
DAMAGED AREAS SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR BETTER UPON COMPLETION OF ALL WORK TO THE SATISFACTION
OF THE CONSTRUCTION MANAGER.
11. THE FOLLOWING CLEANUP TASKS SHALL BE PERFORMED AS FOLLOWS: (1) ON A DAILY BASIS. KEEP THE GENERAL AREA CLEAN AND HAZARD
FREE, REMOVING ALL WASTE, DEBRIS AND TRASH FROM THE SITE AND DISPOSING OF SAME IN A LEGAL MANNER. (2) UPON COMPLETION.
LEAVE THE PREMISES IN A CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE.
12. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE RESPECTIVE MANUFACTURER'S RECOMMENDATIONS
EXCEPT WHERE IT IS SPECIFICALLY INDICATED OTHERWISE IN THE CONTRACT DOCUMENTS OR WHERE LOCAL CODES OR REGULATIONS
TAKE PRECEDENCE.
13. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND
ORDINANCES. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS. ORDINANCES, RULES, REGULATIONS AND LAWFUL
ORDERS OF ANY PUBLIC AUTHORITY HAVING JURISDICTION OVER THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL
SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AS WELL AS
LOCAL AND STATE CODES. ORDINANCES AND APPLICABLE REGULATIONS.
14. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AT ALL TIMES. USING THE BEST SKILLS AND ATTENTION. HE SHALL BE SOLELY
RESPONSIBLE FOR ALL OF THE CONSTRUCTION MEANS. METHODS. TECHNIQUES. SEQUENCES AND PROCEDURES AND FOR COORDINATING
ALL PORTIONS OF THE WORK. INCLUDING CONTACT AND COORDINATION WITH THE CONSTRUCTION MANAGER AND WITH THE OWNER'S
AUTHORIZED REPRESENTATIVE.
15. WITHIN TEN (10) WORKING DAYS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT
DRAWINGS. SWEEP TEST. CYLINDER TESTS. LIEN RELEASES. AND OTHER CLOSEOUT DOCUMENTATION AS REQUIRED BY THE OWNER. ALL
SYSTEMS SHALL BE COMPLETELY ASSEMBLED, TESTED, ADJUSTED AND DEMONSTRATED TO BE READY FOR OPERATION PRIOR TO THE
OWNER'S ACCEPTANCE.
16. THE PROPOSED INSTALLATION WILL NOT:
· INTERFERE WITH THE SAFE OPERATION OF TRAFFIC CONTROL EQUIPMENT;
· INTERFERE WITH SIGHT LINES OR CLEAR ZONES FOR TRANSPORTATION, PEDESTRIANS, OR PUBLIC SAFETY PURPOSES;
· INTERFERE WITH COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT OR SIMILAR FEDERAL OR STATE STANDARDS
VERIZON WIRELESS MEETS ALL FCCS PLANNING IN REGARDS TO FREQUENCY AND POWER ASSIGNMENTS. THIS TAKES INTO ACCOUNT
PUBLIC SAFETY AS WELL AS COMMERCIAL DEPLOYMENTS OF WIRELESS SYSTEMS. IN DOING SO, ISSUES WITH INTERFERENCE ARE VERY
RARE BY DESIGN AND VERIZON WIRELESS ADHERES, TO ESTABLISHED FFC PROCEDURES SHOULD ANYTHING ARISE.
1. MATERIAL:
A. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE LATEST EDITION OF THE AISC "STEEL CONSTRUCTION MANUAL".
B. ALL STRUCTURAL STEEL WF BEAMS SHALL BE ASTM A992 AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM
A153 STANDARDS.
C. ALL STRUCTURAL PLATES, ANGLES. AND CHANNELS SHALL BE ASTM A36 AND ”HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM
A123 AND ASTM A153 STANDARDS.
D. ALL TS MEMBERS SHALL BE ASTM A500 GRADE B (Fy=46ksi), AND ”HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM
A153 STANDARDS.
E. ALL STRUCTURAL PIPE MEMBERS SHALL BE ASTM A500 GRADE B (Fy-42ksi), AND ”HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM
A123 AND ASTM A153 STANDARDS.
F. ALL NON-STRUCTURAL PIPE MEMBERS SHALL BE ASTM A53 GRADE B, AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123
AND ASTM A153 STANDARDS.
2. DESIGN, FABRICATION, AND CONSTRUCTION OF ALL CONNECTIONS SHALL CONFORM TO AISC STEEL CONSTRUCTION MANUAL.
3. WELDING:
A. ALL WELDS, WELDERS, AND WELD INSPECTIONS SHALL CONFORM TO THE REQUIREMENTS OF AWS D 1.1, LATEST REVISION.
B. ALL WELDS SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES.
C. ALL STEEL SHALL BE SPRAY GALVANIZED AFTER WELDING.
4. ALL BOLTS SHALL BE GALVANIZED 3/4" DIAMETER, A325-N, UNLESS NOTED OTHERWISE AND TIGHTENED TO A “SNUG TIGHT'” CONDITION AS
DEFINED BY AISC. SECURE NUT WITH LOCKING WASHER.
5. ANCHOR BOLTS SHALL CONFORM TO ASTM A307, UNLESS NOTED OTHERWISE.
6. THE CONTRACTOR/STEEL FABRICATOR SHALL LOCATE ANY REINFORCEMENT IN THE STRUCTURAL MEMBERS IN SUCH A MANNER SO THAT
THERE WILL NOT BE CONFLICT WITH THE REINFORCEMENT WHEN INSTALLING ANCHORS. THE ANCHORS SHALL BE INSTALLED PER THE
MANUFACTURER'S INSTRUCTION.
7. THE CONTRACTOR/STEEL FABRICATOR SHALL CONFORM TO THE MINIMUM EDGE DISTANCE REQUIREMENTS IN ACCORDANCE WITH THE AISC
MANUAL OF STEEL CONSTRUCTION.
8. ALL STRUCTURAL STEEL SHALL BE FABRICATED TO FIT AT BOLTED CONNECTIONS WITHIN 1/16 INCH TOLERANCE. STRUCTURAL STEEL SHALL
NOT BE FLAME CUT UNDER ANY CIRCUMSTANCES WITHOUT APPROVAL OF THE ENGINEER.
9. THE CONTRACTOR/STEEL FABRICATOR SHALL CAP OR SEAL ALL PIPES AS REQUIRED TO PREVENT RAINWATER INTRUSION.
10. THE CONTRACTOR/STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO ANY STEEL FABRICATION. AT THE
CONTRACTOR'S OPTION, FIELD SPLICES MAY BE USED FOR ERECTION PURPOSES. IF FIELD SPLICES ARE USED. THE SHOP DRAWINGS SHALL
INCLUDE ALL DETAILS FOR THE PROPOSED FIELD SPLICES.
11. AT THE CONTRACTOR'S OPTION, SHOP WELDS MAY BE USED INSTEAD OF FIELD WELDS.
12. SUBMIT ORIGINAL SHOP DRAWINGS. INCLUDING COMPLETE DETAILS. SCHEDULES OF FABRICATION AND ASSEMBLY, PROCEDURES, AND
DIAGRAMS. INCLUDE DETAILS OF CUTS, CONNECTIONS, CAMBER, HOLE, AND OTHER PERTINENT DATA. INDICATE WELDS BY STANDARD AWS
A2.1 AND A2.4 SYMBOLS, AND SHOW SIZE, LENGTH, AND TYPE OF WELD. PROVIDE SETTING DRAWINGS, TEMPLATES, AND DIRECTIONS FOR
INSTALLATION OF ANCHOR BOLTS AND OTHER ANCHORAGES TO BE INSTALLED AS WORK OF OTHERS' SECTIONS.
5. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES THAT INTERFERE WITH THE EXECUTION OF THE WORK SHALL
BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS THAT WILL NOT INTERFERE WITH THE EXECUTION OF
THE WORK, SUBJECT TO THE APPROVAL OF THE CITY AND/OR LOCAL UTILITIES.
6. DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION SHALL BE MINIMIZED.
7. ANY AREAS OF THE CONSTRUCTION SITE DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL
BE GRADED TO A UNIFORM SLOPE. SUCH GRADING SHALL CAUSE SURFACE WATER TO FLOW AWAY FROM ANY EQUIPMENT AND POLE AREAS
AND THE SOIL SHALL BE STABILIZED TO PREVENT EROSION. EROSION CONTROL MEASURES REQUIRED DURING CONSTRUCTION, SHALL BE IN
CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL.
8. THE SUB-GRADE SHALL BE COMPACTED AND BROUGHT TO A UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION.
9. BACKFILL SHALL CONSIST OF CLEAN SAND FILL APPROVED FOR USE BY THE ENGINEER. NO UNAPPROVED MATERIAL WILL BE ALLOWED.
CLEAN SAND FILL SHALL BE FREE OF ALL ROOTS, BOULDERS, OR OTHER DELETERIOUS MATERIAL.
10. THE CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EQUAL TO OR BETTER CONDITION THAN ORIGINAL.
11. SITE SIGNAGE SHALL BE PROVIDED IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR SUCH SIGNAGE AS MAY BE CONTAINED IN
THESE DRAWINGS.
1. THE APPROPRIATE UTILITY LOCATING SERVICES SHALL BE CONTACTED PRIOR TO THE START OF CONSTRUCTION IN ORDER TO VERIFY THE
EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES.
2. THE INSTALLATION OF NEW UTILITIES SHALL BE COORDINATED WITH LOCAL AUTHORITIES.
3. ALL EXISTING ACTIVE SEWER, WATER, GAS. ELECTRIC AND OTHER UTILITIES, WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT
ALL TIMES. WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SUCH UTILITIES SHALL BE RELOCATED BY THE CONTRACTOR AS
DIRECTED BY THE CONSTRUCTION MANAGER. EXTREME CAUTION SHALL BE USED WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR
UTILITIES.
GENERAL NOTES:SITE WORK NOTES:
STRUCTURAL STEEL NOTES:
CBY
TELECOM DESIGN GROUP
DISCLAIMER:
6505 N HIMES AVE.
TAMPA, FLORIDA 33614
(770) 853-1233
FL CA# 31014
PREPARED FOR---------..
verizon✓
7701 E TELECOM PKWY
TEMPLE TERRACE, FL 33637
PROJECT INFOR'-IATION -------
ISSUED DATES ----------
09 .03.21
SHEET NAME---------
SHEET NUMBER ----------
X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
P
P
P
P
P
P
P
P
F
F
F
F
F
F
F
F
F
C-1
9/02/2021
NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATION
OF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGN
GROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVR
TELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANS
ARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BE
CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT
APPROVALS ARE OBTAINED.
610397
SELVA MARINA RELO - COW
469 11TH ST
ATLANTIC BEACH, FL 32233
CBVR PROJECT #: VZW.125.21
ISSUE FOR PERMIT / CONSTRUCTION0
OVERALL VIEW WITH AERIALOVERALL VIEW WITH AERIAL25' 50'
11x17 SCALE: 1"=50'
GRAPHIC SCALE
(SCALE IN FEET)
0'
PROPOSED TEMPORARY 102' COW WITH
VERIZON WIRELESS ANTENNAS
PARCEL ID:
172026-0000
EXISTING PROPERTY
BOUNDARY LINE, APPROX.
EXISTING CHAIN-LINK FENCE,
TYP.
PROPOSED EQUIPMENT CABINETS AND
ELECTRICAL EQUIPMENT ON PROPOSED
COW,
COORDINATE LOCATION
LATITUDE: 30.336157
LONGITUDE: -81.405452
PROPOSED ELECTRICAL POWER ROUTE TO
EXISTING METER ALONG FENCE LINE
CONDUIT TO BE ABOVE GROUND SCH. 80
SUPPORTED BY UNISTRUTS ON SLEEPERS (±430' )
11TH STREET
L
I
N
K
S
I
D
E
D
R
I
V
E
PROPOSED 40'X30' LEASE AREA
FOR TEMPORARY USE COW
EXISTING VERIZON WIRELESS LP
GENERATOR AND 500 GAL. LP TANK TO
BE RELOCATED AND USED BY LESSEE
EXISTING
BUILDINGEXISTING
BUILDING
EXISTING
BUILDING
EXISTING
BUILDING
L
I
N
K
S
I
D
E
D
R
I
V
E
±
3
0
'
±40'
EXISTING EQUIPMENT TO BE
REMOVED AND STORED, BY OTHERS
RELOCATED EXISTING VERIZON WIRELESS
LP GENERATOR ON CONCRETE BALLASTS
RELOCATED EXISTING VERIZON WIRELESS
500 GAL. LP TANK ON CONCRETE BALLASTS
±
6
'
EXISTING ELECTRICAL H-FRAME
WITH METER CENTER TO BE
UTILIZED BY VERIZON WIRELESS
EXISTING WATER TOWER TO BE
REMOVED AND REPLACED WITH
PROPOSED MONOPOLE, BY OTHERS
PROPOSED FIBER ROUTE TO EXISTING FIBER
HAND HOLE AT ROW . CONTRACTOR TO SPLICE
FIBER WITHIN EXISTING HAND HOLE.
CONDUIT TO BE UNDERGROUND FROM FIBER
HAND HOLE TO INSIDE FENCED COMPOUND THEN
ABOVE GROUND WITH SCH. 80 CONDUIT
SUPPORTED BY UNISTRUTS ON SLEEPERS (±430' )
EXISTING DOUBLE
SWINGING ACCESS GATE
HAND DIG TRENCH FROM FIBER
HANDHOLE TO INSIDE FENCED
COMPOUND. COORDINATE WITH VRZ CPM
EXISTING FIBER HANDHOLES AT
ROW CONTRACTOR TO IDENTIFY
VERIZON FIBER HANDHOLE
CBY
TELECOM DESIGN GROUP
DISCLAIMER:
6505 N HIMES AVE.
TAMPA, FLORIDA 33614
(770) 853-1233
FL CA# 31014
~ 01. 1111 111111\\\\
PREPARED FOR
-
verizon✓
7701 E TELECOM PKWY
TEMPLE TERRACE, FL 33637
PROJECT INFOR'-IATION
ISSUED DATES
SHEET NAME
SHEET NUMBER
09 .03.21
P
P
P
P
P
P
P
P
P
F
F
F
F
F
F
F
F
C-2
9/02/2021
NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATION
OF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGN
GROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVR
TELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANS
ARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BE
CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT
APPROVALS ARE OBTAINED.
610397
SELVA MARINA RELO - COW
469 11TH ST
ATLANTIC BEACH, FL 32233
CBVR PROJECT #: VZW.125.21
ISSUE FOR PERMIT / CONSTRUCTION0
PROPOSED COW
COMPOUND PLANPROPOSED COW COMPOUND PLAN
3' 6'
11x17 SCALE: 1"=6'
GRAPHIC SCALE
(SCALE IN FEET)
0'
PROPOSED TEMPORARY 102' COW WITH
VERIZON WIRELESS ANTENNAS
PROPOSED EQUIPMENT CABINETS AND
ELECTRICAL EQUIPMENT ON PROPOSED COW,
COORDINATE LOCATION
LATITUDE: 30.336157
LONGITUDE: -81.405452
PROPOSED 40'X30' LEASE AREA
FOR TEMPORARY USE COW
RELOCATED EXISTING VERIZON WIRELESS
LP GENERATOR ON CONCRETE BALLASTS
RELOCATED EXISTING VERIZON WIRELESS
500 GAL. LP TANK ON CONCRETE BALLASTS
±
3
0
'
±40'
±
6
'
EXISTING
CONCRETE AREA
10' SAFETY BUFFER
EXISTING
GRASSY AREA
EXISTING
GRASSY AREA
PROPOSED ELECTRICAL POWER ROUTE TO
EXISTING METER ALONG FENCE LINE
CONDUIT TO BE ABOVE GROUND SCH. 80
SUPPORTED BY UNISTRUTS ON SLEEPERS (±430' )
PROPOSED FIBER ROUTE TO EXISTING FIBER
HAND HOLE AT ROW . CONTRACTOR TO SPLICE
FIBER WITHIN EXISTING HAND HOLE.
CONDUIT TO BE UNDERGROUND FROM FIBER
HAND HOLE TO INSIDE FENCED COMPOUND THEN
ABOVE GROUND WITH SCH. 80 CONDUIT
SUPPORTED BY UNISTRUTS ON SLEEPERS (±430' )
PROPOSED FIBER CABINET ON PREFAB
CONCRETE SLAB SEE DETAIL SHT C-5
/
I I ~~------~--------------_--I
I ----~
I \
--------
-
\ \ 0 i
/G.\ /
---------
'1---'-----/
\ -------/
\
\
\
\
\ -\ --l ------------------~---------------------
\
\
_J
BY
TELECOM DESIGN
6505 N HIMES GROUP
TAMPA AVE (770~\0
5~'. ~~3~3614
FL CA# 31014
erizon
7701 ET TEMPLE TE~~~COM PKWY CE, FL 33637
C-3
9/02/2021
NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATION
OF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGN
GROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVR
TELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANS
ARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BE
CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT
APPROVALS ARE OBTAINED.
610397
SELVA MARINA RELO - COW
469 11TH ST
ATLANTIC BEACH, FL 32233
CBVR PROJECT #: VZW.125.21
ISSUE FOR PERMIT / CONSTRUCTION0
PROPOSED TOWER
ELEVATION
NOTES:
1. REQUEST CURRENT RFDS BEFORE INSTALLATION
2. ANTENNA DIAGRAMS ARE FROM RFDS
T.O. SECTION
±105'
TRAILER
TELESCOPING TOWER
PROPOSED (18) 1/2" Ø
COAXIAL CABLES
SECURED TO THE COW
PROPOSED VZW ANTENNAS
RAD CENTER ±102'
PROPOSED ANTENNA MOUNT DETAIL & SCHEDULE
NOT TO SCALE
ANT.
MARK SECTOR PROPOSED ANTENNA AZIMUTH
RAD
CENTER
ELEC
DOWN
MECH
DOWN CABLE LENGTH PROPOSED CABLE
A-1 A NHH-65B-R2B 0° 102' * *
110 +/- LFT (18) 1/2" Ø
COAXIAL CABLEB-1 B 120° 102' * *
* *
PROPOSED COW ELEVATION
NOT TO SCALE
AZ
=
A
N
T
E
N
N
A
B
-
1
12
0
.
0
0
°
PROPOSED (3) ANTENNAS
MOUNTED TO TEMPORARY COW
PROPOSED NHH-65B-R2B
ANTENNA (TYP. OF 3)
* PER RFDS
EL.
102'
AZ
=
AN
T
E
N
N
A
A
-
1
0°
PROPOSED RRU MOUNT DETAIL
NOT TO SCALE
PROPOSED RRU 4449 (TYP. OF 3)
PROPOSED RRU 8843 (TYP. OF 3)
EL.
98'
PROPOSED VZW RRUS
RAD CENTER ±98'
C-1 C
NHH-65B-R2B
NHH-65B-R2B 240° 102'
AZ=ANTE
N
N
A
C
-
1
240.
0
0
°
GROUND LEVEL
PROPOSED DBC-A-P-4SF QUADPLEXER
(TYP. OF 3, 1 PER SECTOR)
NOTE:
1. CBVR HAS NOT COMPLETED A STRUCTURAL ANALYSIS
REPORT OF THE PROPOSED COW, GUY WIRES, OR
BALLAST AS PART OF OUR SCOPE.
2. REFERENCE COW STRUCTURAL ANALYSIS REPORT BY
OTHERS. AND FOLLOW ALL REQUIRED
SPECIFICATIONS FOR GUY WIRE AND BALLAST SIZE,
WEIGHT, TENSION, AND CONFIGURATION.
\ \_
----~..,_; --------~~
V
CBV
TELECOM DESIGN GROUP
DISCLAIMER:
6505 N HIMES AVE.
TAMPA, FLORIDA 33614
(770) 853-1233
FL CA# 31014
PREPARED FOR-------~
verizon✓
7701 E TELECOM PKWY
TEMPLE TERRACE, FL 33637
PROJECT INFORMATION-----------..
ISSUED DATES
09.03.21
SHEET NAME---------
SHEET NUMBER -------
C-4
9/02/2021
NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATION
OF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGN
GROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVR
TELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANS
ARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BE
CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT
APPROVALS ARE OBTAINED.
610397
SELVA MARINA RELO - COW
469 11TH ST
ATLANTIC BEACH, FL 32233
CBVR PROJECT #: VZW.125.21
ISSUE FOR PERMIT / CONSTRUCTION0
COW DETAILS
PROPOSED COW DETAILS
NOT TO SCALE
I N D U S T R I E S • I N C. Industry leader setting the standard for mobile tower vertical loading.
Peak Industries Inc.
Standard Trailer w/ 120' Pinned Tower
Trailer:
Model: PK-120PTH
Dimensions: 8'6" x 21'6" {80" x 18' Deck)
Deck Height: 24"
Deck Material: 14ga Diamond Treadplate
Axels: Tandem 7000Ib Axle's {Total GVWR 14000Ibs) Optional Weights
Dry Weight: 9520Ibs
lounge: Ball 2 5/16"
Tower:
Model: PK-120PTH (Pinned Tower Horizontal Travel)
Height: 120' Rad Center
Mechanical: Hydraulic
Structural: Steel Tube ¼" Wall (Engineered 90 mph Winds, ½" Radial Ice)
Locking Mechanism: Pinned (Manual)
Support: Guyed -¼" Galvanized IPS Wire Rope
CBY
TELECOM DESIGN GROUP
DISCLAIMER:
6505 N HIMES AVE.
TAMPA, FLORIDA 33614
(770) 853-1233
FL CA# 31014
PREPARED FOR--------
verizon✓
7701 E TELECOM PKWY
TEMPLE TERRACE, FL 33637
PROJECT INFOR'-IATION -------
ISSUED DATES
09 .03.21
SHEET NAME----------
SHEET NUMBER --------
C-5
9/02/2021
NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATION
OF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGN
GROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVR
TELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANS
ARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BE
CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT
APPROVALS ARE OBTAINED.
610397
SELVA MARINA RELO - COW
469 11TH ST
ATLANTIC BEACH, FL 32233
CBVR PROJECT #: VZW.125.21
ISSUE FOR PERMIT / CONSTRUCTION0
CONSTRUCTION DETAILS
FOR CONDUIT & FIBER SUPPORT
PROPOSED DURA-BLOK CABLE SUPPORT
(B-LINE (DURA-BLOK) P/N DBXX).
INSTALL PER MANUFACTURER'S
RECOMMENDATIONS AT 5'-0" O.C. MAX.
2'-8"
24"x24" MAT
CONDUIT CABLE SUPPORT SLEEPER DETAIL
PROVIDE DURA-BLOK (OR APPROVED EQUAL)
SLEEPERS, GALVANIZED OR ALIMINUM
UNISTRUT FRAME.
CABLE SUPPORT DETAILS
NOT TO SCALE
PROPOSED DURA-BLOK CABLE SUPPORT
(B-LINE (DURA-BLOK) P/N DBXX).
INSTALL PER MANUFACTURER'S
RECOMMENDATIONS AT 5'-0" O.C. MAX.
PROPOSED
CONDUIT, TYP.
PROPOSED 36" x 48" x 4" HURRICANE PAD
ITEM # H3648-4 BY DIVERSITECH OR
APPROVED EQUIVALENT
CABINET ANCHOR DETAIL
NOT TO SCALE
PROPOSED FIBER CABINET
PROPOSED HURRICANE PADPROPOSED 36" x 48" x 4" HURRICANE PAD
ITEM # H3648-4 BY DIVERSITECH OR
APPROVED EQUIVALENT
SECURED THE FIBER CABINET WITH
(2) AUGER STYLE EARTH ANCHOR
STRAP CABINET WITH 1-1/4 GALVANIZED
STEEL STRAPS AND OR 7/32 CABLES
FISH STRAP THOUGHT THE
CABINET PULL BRACKETS
P·art No. Height Width Overan Length
DBS 511 (127mm) 6u (152mm) 4.8'"' (122mm)
D810 5" (127mm) 6" (152mm) 9.6" 1244mm)
D820 5" (127mm) 6' (152mm) 20.2" (513mm)
D830 5" (127mm) 6' (152mm) 30.8' (782mm)
D840 5' (1127mm) 6" (152mm) 41 .4" (1052mm)
D848 5" (127mm) 6" (152mm) 52.0JI (1321 mm) DB10
CBY
TELECOM DESIGN GROUP
DISCLAIMER:
6505 N HIMES AVE.
TAMPA, FLORIDA 33614
(770) 853-1233
FL CA# 31014
PREPARED FOR-------
verizon✓
7701 E TELECOM PKWY
TEMPLE TERRACE, FL 33637
PROJECT INFOR'-IATION ------
ISSUED DATES -------
09 .03.21
SHEET NAME-------
SHEET NUMBER --------
C-6
9/02/2021
NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATION
OF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGN
GROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVR
TELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANS
ARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BE
CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT
APPROVALS ARE OBTAINED.
610397
SELVA MARINA RELO - COW
469 11TH ST
ATLANTIC BEACH, FL 32233
CBVR PROJECT #: VZW.125.21
ISSUE FOR PERMIT / CONSTRUCTION0
CONSTRUCTION DETAILS
SIDE VIEW END VIEW
TIE @ CONCRETE FLOOR
NOTE:
IF IT IS REQUIRED TO APPRECIABLY ALTER THE LENGTH OF THE FUEL LINE
OR THE NUMBER OF BENDS FROM WHAT IS SHOWN IN THIS DIAGRAM,
CONTRACTOR SHALL CONTACT ENGINEERING FIRM FOR RECALCULATION
OF FUEL LINE SIZE.
1. PIPING (EFFECTIVE LENGTH) = 25'
2. FUEL DEMAND OF GENERATOR = 546,862 BTU/HR
3. BTU CAPACITY OF PIPING SYSTEM = 1,843,000 BTU/HR
4. ABOVE GROUND GALVANIZED PIPING SHALL BE GALVANIZED STEEL PIPING PER ASME B31.3
5. ALL GAS PIPING MATERIALS AND INSTALLATION TO BE IN ACCORDANCE WITH NFPA 58 AND 2017 FUEL GAS.
PROPANE
GENERATOR
3/4" SCH 40
METALLIC PIPE
DIELECTRIC UNION
AUTOMATIC SHUT OFF
VALVE, IF NOT SUPPLIED
WITH GENERATOR (SEE
NOTE 6)
11" W.C. SECOND STAGE
PROPANE REGULATOR
3/4" SCH 40 GALVANIZED
STEEL PIPING (SEE NOTE 4)
LENGTH = 1'-6"
FBC TABLE 402.4(25)
STEEL 500
GALLON PROPANE
TANK
DIELECTRIC UNION
10 PSI 1ST STAGE
PROPANE
REGULATOR
MANUAL SHUT
OFF VALVE
3/4" SCH 40
GALVANIZED STEEL
PIPING LENGTH = 25'-0"
(SEE NOTE 4)
FUEL LINE DETAIL
NOT TO SCALE
1-1/4" GALVANIZED
STEEL CLASS B
STRAP
GROUND AUGER
STYLE GROUND
ANCHOR
NOTE: VIEWS OF PROPANE TANK ARE FOR
INFORMATIONAL PURPOSES ONLY. SEE
MANUFACTURERS SPECIFICATIONS FOR EXACT
DIMENSIONS AND DETAILS.
TOP VIEW
PROPOSED 18" x 40" x 4" HURRICANE PAD
ITEM # H1840-4 BY DIVERSITECH OR
APPROVED EQUIVALENT
SECURED THE TANK WITH
(4) AUGER STYLE EARTH ANCHOR
STRAP CABINET WITH 1-1/4 GALVANIZED
STAINLESS STEEL STRAPS
GENERATOR
METAL
ENCLOSURE
PROPOSED 18" x 40" x 4" HURRICANE PAD
ITEM # H1840-4 BY DIVERSITECH OR
APPROVED EQUIVALENT
SECURED THE GENERATOR WITH
(4) AUGER STYLE EARTH ANCHOR
STRAP GENERATOR WITH (2) 1-1/4
GALVANIZED STAINLESS STEEL STRAPS
AND OR 7/32 CABLES
PROPANE TANK ANCHOR DETAIL
NOT TO SCALE
PROPANE GENERATOR ANCHOR DETAIL
NOT TO SCALE
1-1/4" GALVANIZED
STEEL CLASS B
STRAP
NOTE: CONTRACTOR TO PREPARE THE GROUND
SURFACE FREE OF ANY ORGANIC MATERIAL
PRIOR TO THE INSTALLATION OF THE PREFAB
HURRICANE PADS
NOTES:
1. CONTRACTOR TO PROVIDE & INSTALL A 500 GALLON LP TANK PER ASME & N.F.P.A. 58 (MOST CURRENT
EDITIONS).
2. DESIGN CODE: ASME BOILER AND PRESSURE VESSEL CODE, SECTION VIII, DIVISION I, MOST CURRENT EDITION
AND ADDENDUMS
3. DESIGN STANDARDS: N.F.P.A. 58 LP GAS CODE
4. DESIGN CONDITIONS: WATER CAPACITY = 500 GALLONS ALLOWABLE WORKING PRESSURE(PSIG) = 250
HYDROSTATIC TEST PRESSURE(PSIG) = 325
5. WIRELESS LPG FUEL MONITORING SYSTEM TO BE PROVIDED BY VERIZON AND INSTALLED BY CONTRACTOR.
CONTRACTOR TO INSTALL SO THAT UNIT HAS A DIRECT VIEW TO THE LPG TANK.
6. TANK SHALL BE EQUIPPED WITH ROCHESTER WIRELESS REMOTE READY GAUGE WITH REED SWITCH MODULE
(OR EQUIVALENT).
7. AFTER TANK INSTALLATION THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INITIAL FUELING.
8. CONTRACTOR SHALL INSTALL A MANUAL SHUT-OFF VALVE. TANK LID SHALL BE SIZED APPROPRIATELY TO
ACCOMMODATE ADDITION OF SHUT-OFF VALVE. SHUT-OFF VALVE SHALL MEET THE CODE REQUIREMENTS OF
NFPA 58.11.15.2.3.
GAS PIPING NOTES FOR LINE BETWEEN 2ND STAGE REGULATOR & GENERATOR (PER 7TH EDITION 2020 FLORIDA
BUILDING CODE FUEL GAS):
1. PIPING (EFFECTIVE LENGTH) = < 10'
2. FUEL DEMAND OF GENERATOR = 546,862 BTU/HR
3. BTU CAPACITY OF PIPING SYSTEM = 608,000 BTU/HR
4. ABOVE GROUND GALVANIZED PIPING SHALL BE GALVANIZED STEEL PIPING PER ASME B31.3
5. ALL GAS PIPING MATERIALS AND INSTALLATION TO BE IN ACCORDANCE WITH 7TH EDITION 2020 FLORIDA
BUILDING CODE FUEL GAS.
6. GENERATOR SHALL BE EQUIPPED WITH A MANUAL AND AN AUTOMATIC SHUT-OFF VALVE PER NFPA 37,
SECTION 5.4.
GAS PIPING NOTES FOR LINE BETWEEN 1ST & 2ND STAGE REGULATORS (PER NFPA 58):
1-
Q
1-1-
=== === === === === ~~ = === === === === ===
CBY
TELECOM DESIGN GROUP
DISCLAIMER:
6505 N HIMES AVE.
TAMPA, FLORIDA 33614
(770) 853-1233
FL CA# 31014
PREPARED FOR------------..
verizon✓
7701 E TELECOM PKWY
TEMPLE TERRACE, FL 33637
PROJECT INFOR'-IATION -------
ISSUED DATES ---------
09 .03.21
SHEET NAME---------
SHEET NUMBER ---------
E-1
9/02/2021
NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATION
OF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADE
WITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGN
GROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVR
TELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANS
ARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BE
CONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENT
APPROVALS ARE OBTAINED.
610397
SELVA MARINA RELO - COW
469 11TH ST
ATLANTIC BEACH, FL 32233
CBVR PROJECT #: VZW.125.21
ISSUE FOR PERMIT / CONSTRUCTION0
GROUNDING DETAILS
EXTERIOR GROUND RING. #2
SOLID BARE TINNED COPPER
GROUNDING CONDUCTOR
NO SLAG OR
DEFORMITIES ALLOWED
EXOTHERMIC WELD
(THERMOWELD OR
EQUIVALENT) PARALLEL, NO
T-WELD ALLOWED.
MIN. TURNING
RADIUS 45° (TYP.)
JUMPER. #2 SOLID BARE
TINNED COPPER
GROUNDING CONDUCTOR
EXOTHERMIC WELD DETAIL
ELECTRICAL NOTES:
ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION OF THE
NATIONAL ELECTRICAL CODE (N.E.C.), AND APPLICABLE LOCAL CODES.
GROUNDING SHALL COMPLY WITH ARTICLE 250 OF NATIONAL ELECTRICAL
CODE.
ALL ELECTRICAL ITEMS SHALL BE U.L. APPROVED OR LISTED.
ALL WIRES SHALL BE AWG MIN #12 THHN COPPER UNLESS NOTED.
CONDUCTORS SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUIT UNLESS
NOTED OTHERWISE.
ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND
STRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 8"
RADIUS.
ENGAGE AN INDEPENDENT TESTING FIRM TO TEST AND VERIFY THAT
RESISTANCE DOES NOT EXCEED 5 OHMS TO GROUND. TEST GROUND RING
RESISTANCE PRIOR TO MAKING FINAL GROUND CONNECTIONS TO
INFRASTRUCTURE AND EQUIPMENT. GROUNDING AND OTHER OPERATIONAL
TESTING SHALL BE WITNESSED BY VERIZON WIRELESSS REPRESENTATIVE.
PROVIDE PULL BOXES AND JUNCTION BOXES WHERE REQUIRED SO THAT
CONDUIT BENDS DO NOT EXCEED 360°.
OBTAIN PERMITS AND PAY FEES RELATED TO ELECTRICAL WORK
PERFORMED ON THIS PROJECT. DELIVER COPIES OF ALL PERMITS TO
VERIZON WIRELESS REPRESENTATIVE.
SCHEDULE AND ATTEND INSPECTIONS RELATED TO ELECTRICAL WORK
REQUIRED BY JURISDICTION HAVING AUTHORITY. CORRECT AND PAY FOR
ANY WORK REQUIRED TO PASS ANY FAILED INSPECTION.
REDLINED AS-BUILTS ARE TO BE DELIVERED TO VERIZON WIRELESS
REPRESENTATIVE.
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL
APPLICABLE BUILDING CODES AND LOCAL ORDINANCES, INSTALLED IN A
NEAT MANNER, AND SHALL BE SUBJECT TO APPROVAL BY VERIZON
WIRELESS REPRESENTATIVE.
CONDUCT A PRE-CONSTRUCTION SITE VISIT AND VERIFY EXISTING SITE
CONDITIONS AFFECTING THIS WORK. REPORT ANY OMISSIONS OR
DISCREPANCIES FOR CLARIFICATION PRIOR TO THE START OF
CONSTRUCTION.
PROTECT ADJACENT STRUCTURES AND FINISHES FROM DAMAGE. REPAIR TO
ORIGINAL CONDITION ANY DAMAGED AREA.
REMOVE DEBRIS ON A DAILY BASIS. DEBRIS NOT REMOVED IN A TIMELY
FASHION WILL BE REMOVED BY OTHERS AND THE RESPONSIBLE
SUBCONTRACTOR SHALL BE CHARGED ACCORDINGLY. REMOVAL OF DEBRIS
SHALL BE COORDINATED WITH THE OWNER'S REPRESENTATIVE. DEBRIS
SHALL BE REMOVED FROM THE PROPERTY AND DISPOSED OF LEGALLY.
UPON COMPLETION OF WORK, THE SITE SHALL BE CLEAN AND FREE OF DUST
AND FINGERPRINTS.
TYP. METALLIC GROUNDING DETAIL
GROUNDING NOTES:
ALL DOWN GROUND WIRE AND GROUND SYSTEM WIRE SHALL BE #2 AWG, SOLID,
BARE, TINNED COPPER. ALL CONNECTIONS TO GROUND SYSTEM SHALL BE
EXOTHERMICALLY WELDED.
WHERE MECHANICAL GROUNDING CONNECTIONS ARE SPECIFIED, BOLTED,
COMPRESSION-TYPE CLAMPS OR SPLIT-BOLT TYPE CONNECTORS SHALL BE USED.
GRIND OFF GALVANIZING IN AFFECTED AREA. EXOTHERMICALLY WELD #2
CONDUCTOR. COLD-GALV AFTER. EXOTHERMICALLY WELD OTHER END TO GROUND.
FOLLOWING COMPLETION OF WORK, CONDUCT GROUND TEST. SUBMIT WRITTEN
TEST TO CONSTRUCTION MANAGER AND PROJECT MANAGER.
ALL GROUNDING WORK SHALL COMPLY WITH VERIZON WIRELESS STANDARDS.
UNLESS NOTED OTHERWISE, ALL GROUNDING SHALL BE IN ACCORDANCE WITH
VERIZON WIRELESS'S REQUIREMENTS FOR "BONDING, GROUNDING AND TRANSIENT
PROTECTION FOR CELL SITES", AND "SITE RESISTANCE TO EARTH TESTING". ALL
GROUNDING SHALL ALSO COMPLY WITH ALL STATE AND LOCAL CODES, AND THE
NATIONAL ELECTRICAL CODE (NEC).
UNLESS NOTED OTHERWISE, ALL GROUNDING CONNECTIONS SHALL BE MADE BY AN
EXOTHERMIC WELD.
RESISTANCE TO EARTH TESTING IS REQUIRED PER NEC STANDARDS ON ALL NEW
SITES.
NEW INSTALLED ANTENNA PIPE MOUNTS SHALL BE EXOTHERMICAL GROUNDED W/
#2 AWG SOLID TINNED COPPER TO EXISTING GROUND SYSTEM (EACH SECTOR).
ALL NEW COAX OR HYBRID CABLES SHALL BE GROUNDED W/ SUPPLIED GROUND KIT
TO SECTOR GROUND SYSTEM.
COVER
HANDHOLE SHALL BE
A MINIMUM OF 12"Wx12"L
FINISH
GRADE
MIN. 30" DEPTH
EXISTING
EARTH
2 AWG
TEST PIGTAIL
MIN. 30"
BELOW FROSTLINE
GROUND RING SHALL BE
A MINIMUM OF 30" BELOW GRADE AND
BE BELOW LOCAL FROSTLINE
6"
EXOTHERMIC WELD CONNECTION
TREATED WITH TWO (2) COATS COLD
GALVANIZED PAINT
EXOTHERMIC
CONNECTION
DRIVEN COPPER
CLAD GROUND ROD
WELL SIZE OF 12"X24" WITH 6" CLEARANCE BELOW EXOTHERMIC WELD
CONNECTION ALLOWS FOR USE OF CLAMP-ON GROUND METERS FOR
TESTING GROUND SYSTEM.
GROUND ROD DETAIL
N.T.S.
SRC No. 6 AGGREGATES OR SRC CR-6
CRUSH RUN MIN. 12" DEEP
10'-0"
5/8" DIAMETER COPPER CLAD STEEL GROUND
ROD 10' LONG. AT LEAST 8' OF GROUND ROD IN
CONTACT WITH SOIL
GROUND ROD SHALL NOT BE ANGLED MORE
THAN 30° FROM VERTICAL. ANGLE AWAY FROM
SHELTER OR PAD WHERE POSSIBLE.
GROUND
RING
FINISHED GRADE
TEST WELL DETAIL
N.T.S.
4
7/16""
2
3/4"
2 "
1
LEGEND:
1. GROUND BAR, 1/4"X 4"X 20"
2. 5/8" LOCKWASHERS, H.K. PORTER OR APPROVED EQUIVALENT.
3. #2 TWO HOLE LONG BARRELL COMPRESSION LUG BY BURNDY OR APPROVED EQUIVALENT.
4. 5/8-11 X 1" HHCS BOLTS, H.K. PORTER OR APPROVED EQUIVALENT.
* APPLY A NO-OXIDATION COMPOUND BEHIND AND ON ALL CONNECTIONS TO GROUND BUSS
BAR.
GROUND BAR DETAIL
N.T.S.
3
1
N.T.S.
N.T.S.
BRASS TWO HOLE
MECHANICAL
CONNECTOR WITH
STAINLESS
HARDWARE
PARALLEL EXOTHERMIC
WELD TO GROUND RING
#2 AWG BARE
TINNED SOLID
COPPER WIRE
(UNIT BOND)
METALLIC BOX,
HOUSING ETC.
30°
MAX
----------------~
"'"'"'
/
CBY
TELECOM DESIGN GROUP
DISCLAIMER:
6505 N HIMES AVE.
TAMPA, FLORIDA 33614
(770) 853-1233
FL CA# 31014
~ 01.
I I I I //UI I\\\
PREPARED FOR
---
verizon✓
7701 E TELECOM PKWY
TEMPLE TERRACE, FL 33637
PROJECT INFOR'-IATION
ISSUED DATES
SHEET NAME
SHEET NUMBER
09 .03.21