Loading...
1710 Maritime Oak Dr MCRS21-0009 PV Solar SystemOWNER:ADDRESS:CITY:STATE:ZIP: DLUHOS SEBESTO CASEY 1710 MARITIME OAK DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: Titan Solar Power Fl 901 Armstrong Blvd Kissimmee Fl 34741 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 1880 ATLANTIC BEACH COUNTRY CLUB UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1710 MARITIME OAK DR MECHANICAL RESIDENTIAL OTHER PV SOLAR SYSTEM $55000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 SOLAR COLLECTOR SYSTEM 455-0000-322-1000 0 $30.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $89.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 9/24/2021 PERMIT NUMBER MCRS21-0009 ISSUED: 9/24/2021 EXPIRES: 3/23/2022 MECHANICAL RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD 2 of 2Issued Date: 9/24/2021 PERMIT NUMBER MCRS21-0009 ISSUED: 9/24/2021 EXPIRES: 3/23/2022 MECHANICAL RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD DESCRIPTION ACCOUNT QTY PAID PermitTRAK $89.00 MCRS21-0009 Address: 1710 MARITIME OAK DR APN: 169505 1880 $89.00 MECHANICAL $85.00 SOLAR COLLECTOR SYSTEM 455-0000-322-1000 0 $30.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R17324 $89.00 Printed: Friday, September 24, 2021 2:01 PM Date Paid: Friday, September 24, 2021 Paid By: Titan Solar Power Fl Pay Method: CREDIT CARD 516263807 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R17324 ~+; CENTRALSQUARE Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION IN fE'1r l@N l lN E~ ~I@ ~1-iM Musr CAIi. BY 4PM PREVIOUS DAY FOR NIEXI' DAY INSPECIION MCRS21-0009 TSPss Building Permit Application City of Atlantic Beach Building Department 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Bui l ding-Dept@coab.us Updated 10/9/18 **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Job Address: 1710 Maritime Oak Drive Atlantic Beach FL 32233 Permit Number: ___________ _ Legal Description 67-132 08-2S-29E .152 ATLANTIC BEACH COUNTRY CLUB UNIT 2 LOT 117 RE# __________ _ Valuation of Work (Replacement Cost) $_5_5o_o_o _____ Heated/Cooled SF _____ Non-Heated/Cooled _____ _ • Class of Work: □New □Addition 0Alteration □Repair □Move □Demo □Pool □Window/Door • Use of existing/proposed structure(s): □Commercial 0Residential • If an existing structure, is a fire sprinkler system installed?: □Yes □No • Wi ll t r eelsl be removed in association with orooosed oro iect? □Y es /must submit seoarate Tree Remov al Permit\ □No ____ 1 Describe in detail the type of work to be performed: PV SOLAR INSTALLATION Florida Product Approval # ___________________ for multiple products use product approval form Property Owner Information Name DLUHOS SEBESTO CASEY & SEBESTO JASON Address 171 O Maritime Oak Drive Atlantic Beach FL 32233 City Atlantic Beach State _F_L __ Zip 32233 Phone _9_12_)_3_0_8-_5_11_3 ________ _ E-Mail jasonsebesto@gmail.com Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) ____________________ _ Contractor Information Name of Company Titan Solar Power FL Qualifying Agent ________________ _ Address 901 Armstrong Blvd City Kissimmee State _F_L __ Zi p __ 34_7_4_1 __ _ Office Phone _(8_5_5_)7_2_9-_76_5_2 ___________ Job Site Contact Number ________________ _ State Certification/Registration# EC13009924 E-Mail flpermitting@titansolarpower.com Architect Name & Phone# ___________________________________ _ Engineer's Name & Phone It ___________________________________ _ Workers Compensation Insurer Lovitt Marsh Touche A Mcclennan OR Exempt □ Expiration Date _41_1_12_2 _____ _ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of al I the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO R NOTICl OF: COMMENCEMENT. ~ 21 (Signature of Contracto r) Signed and sw orn t o (or affirmed) before me this a day of f\v%usr . aoa ~ <o:-0'\'T ~o('t\tY-~t £=~ (Sig~ature~~ ,~, KRYSTAL RODRIGUEZ OTERO l~ ~Notary Public-State of Florida §;, ;§ Commission, HH 89764 ~z,,_,,,...,1$ My Co a,miui,on E~pires I . . .G~v-0~ TSP86693 Electrical Permit Application City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. PERMIT#: ______ _ JOB ADDRESS: 1710 Maritime Oak Drive Atlantic Beach FL 32233 PROJECT VALUE $_55_0_0_0 ______ _ JEA INFORMATION REQUIRED ON ALL PERMITS: __ AMPS VOLTS PHASE 0 NEW SERVICE: □Overhead □Underground □Underground up Pole □Residential (Main) Service: □0-100 amps (J101-150amps [:)151-200amps O. ___ amps # of Meters __ _ OC:ommercial (Main} Service: □0-100 amps O101-lS0amps IJ1s1-2ooamps □. ___ amps [JCT Service ___ amps Conductor Type _______ Size _____ _ □Multi-Family (iviain) Sen;ice: [l)-100 amps O1Dl-150amps O1Sl-200a mps D ___ amps # of Unit Meters --- □ TEMPORARY POLE: ___ amps □ SERVICE UPGRADE: 0. ___ amps [JCT Service ___ amps 0 NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.): 0100 amps O1soamps □2ooamps D. ___ amps 0:T Service ___ amps □ ADDITIONS, REMODELS, REPAIRS, BUILD-OUTS, ACCESSORY STRUCTURES, ETC: Outlets/Switches: ___ 0-30amps ___ 31-lO0amps ___ 101-200amps Appliances: ___ 0 -30amps ___ 31-lO0amps ___ 101-200amps A/C Circuits: ___ 0-60amps ___ 61-lO0amps Heat Circuits: ___ #circuits @ ___ kw Number of Lighting Outlets, Including Fixtures: __ _ □ OTHER ELECTRICAL PROJECTS: OSwimming Pool []Sign Dsmoke Detectors ___ (Qty) Orransformers ____ KVA □Motors ___ HP □ FIRE ALARM SYSTEM (Requires 3 sets of plans): Qty ____ volts/amps ____ _ □ REPAIRS/MISCELLANEOUS: □Replace Burnt/Damaged Meter Can Q)ther: □Safety Inspection □Panel Change OOH to UG Updated 10/17/18 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. q D I J / ~ / -/"tQQ Owner Name : __ D_L_U_H_O_S_S_E_B_E_S_T_O_C_A_S_E_Y_&_S_E_B_E_S_T_O_J_A_S_O_N ______ Phone Number: 7 fo ~-7 \Vl.11 Electrical Company: _J_EA _______________ Office Phone: 'FOO 41 t3 65 '-1<:l Fax: _____ _ Co. Address : dl W (,hun:,l) 5tree-\-State: _fL Zip: ~Oc}.._ license Holder: Scott ?Dr-+-, -er State Certification/Registration#: EC\ :0 00 9 q a y Notarized Signature of license Holder ---'L'------""::::::::.,--:____J/~2===--±=--4----------------------- e State of Florida, County of ___ _ ~~ KRYSTAL RODRIGUEZ OTERO _ JP ~~Notary Public_:Stete_ol Florida _._ •: Gommissinn # HH AQ7RA Signature of Not.:iry Public __,...::;:ts;~,z;.~~~~.e.J.~~~~~~~------ ~0Aallv Known OR [ 1 Produe'er:1-ldentification Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 09/16/2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 TITAN SOLAR POWER FL INC. (855) 729-7652 flpermitting@titansolarpower.com FILLED IN OMITTED INFORMATION TITAN SOLAR POWER FL INC. 4 4 4 SOLR21-0004 andMCRS21-0009 □ □ □ □ □ □ □ □ □ MCRS21-0009 TSPss Building Permit Application City of Atlantic Beach Building Department 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Bui l ding-Dept@coab.us Updated 10/9/18 **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Job Address: 1710 Maritime Oak Drive Atlantic Beach FL 32233 Permit Number: ___________ _ Legal Description 67-132 08-2S-29E .152 ATLANTIC BEACH COUNTRY CLUB UNIT 2 LOT 117 RE# __________ _ Valuation of Work (Replacement Cost) $_5_5o_o_o _____ Heated/Cooled SF _____ Non-Heated/Cooled _____ _ • Class of Work: □New □Addition 0Alteration □Repair □Move □Demo □Pool □Window/Door • Use of existing/proposed structure(s): □Commercial 0Residential • If an existing structure, is a fire sprinkler system installed?: □Yes □No • Wi ll t r eelsl be removed in association with orooosed oro iect? □Y es /must submit seoarate Tree Remov al Permit\ □No ____ 1 Describe in detail the type of work to be performed: PV SOLAR INSTALLATION Florida Product Approval # ___________________ for multiple products use product approval form Property Owner Information Name DLUHOS SEBESTO CASEY & SEBESTO JASON Address 171 O Maritime Oak Drive Atlantic Beach FL 32233 City Atlantic Beach State _F_L __ Zip 32233 Phone _9_12_)_3_0_8-_5_11_3 ________ _ E-Mail jasonsebesto@gmail.com Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) ____________________ _ Contractor Information Name of Company Titan Solar Power FL Qualifying Agent ________________ _ Address 901 Armstrong Blvd City Kissimmee State _F_L __ Zi p __ 34_7_4_1 __ _ Office Phone _(8_5_5_)7_2_9-_76_5_2 ___________ Job Site Contact Number ________________ _ State Certification/Registration# EC13009924 E-Mail flpermitting@titansolarpower.com Architect Name & Phone# ___________________________________ _ Engineer's Name & Phone It ___________________________________ _ Workers Compensation Insurer Lovitt Marsh Touche A Mcclennan OR Exempt □ Expiration Date _41_1_12_2 _____ _ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of al I the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO R NOTICl OF: COMMENCEMENT. ~ 21 (Signature of Contracto r) Signed and sw orn t o (or affirmed) before me this a day of f\v%usr . aoa ~ <o:-0'\'T ~o('t\tY-~t £=~ (Sig~ature~~ ,~, KRYSTAL RODRIGUEZ OTERO l~ ~Notary Public-State of Florida §;, ;§ Commission, HH 89764 ~z,,_,,,...,1$ My Co a,miui,on E~pires I . . .G~v-0~ Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 09/16/2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 TITAN SOLAR POWER FL INC. (855) 729-7652 flpermitting@titansolarpower.com FILLED IN OMITTED INFORMATION TITAN SOLAR POWER FL INC. 4 4 4 SOLR21-0004 andMCRS21-0009 □ □ □ □ □ □ □ □ □ MCRS21-0009 TSPss Building Permit Application City of Atlantic Beach Building Department 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Bui l ding-Dept@coab.us Updated 10/9/18 **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Job Address: 1710 Maritime Oak Drive Atlantic Beach FL 32233 Permit Number: ___________ _ Legal Description 67-132 08-2S-29E .152 ATLANTIC BEACH COUNTRY CLUB UNIT 2 LOT 117 RE# __________ _ Valuation of Work (Replacement Cost) $_5_5o_o_o _____ Heated/Cooled SF _____ Non-Heated/Cooled _____ _ • Class of Work: □New □Addition 0Alteration □Repair □Move □Demo □Pool □Window/Door • Use of existing/proposed structure(s): □Commercial 0Residential • If an existing structure, is a fire sprinkler system installed?: □Yes □No • Wi ll t r eelsl be removed in association with orooosed oro iect? □Y es /must submit seoarate Tree Remov al Permit\ □No ____ 1 Describe in detail the type of work to be performed: PV SOLAR INSTALLATION Florida Product Approval # ___________________ for multiple products use product approval form Property Owner Information Name DLUHOS SEBESTO CASEY & SEBESTO JASON Address 171 O Maritime Oak Drive Atlantic Beach FL 32233 City Atlantic Beach State _F_L __ Zip 32233 Phone _9_12_)_3_0_8-_5_11_3 ________ _ E-Mail jasonsebesto@gmail.com Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) ____________________ _ Contractor Information Name of Company Titan Solar Power FL Qualifying Agent ________________ _ Address 901 Armstrong Blvd City Kissimmee State _F_L __ Zi p __ 34_7_4_1 __ _ Office Phone _(8_5_5_)7_2_9-_76_5_2 ___________ Job Site Contact Number ________________ _ State Certification/Registration# EC13009924 E-Mail flpermitting@titansolarpower.com Architect Name & Phone# ___________________________________ _ Engineer's Name & Phone It ___________________________________ _ Workers Compensation Insurer Lovitt Marsh Touche A Mcclennan OR Exempt □ Expiration Date _41_1_12_2 _____ _ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of al I the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO R NOTICl OF: COMMENCEMENT. ~ 21 (Signature of Contracto r) Signed and sw orn t o (or affirmed) before me this a day of f\v%usr . aoa ~ <o:-0'\'T ~o('t\tY-~t £=~ (Sig~ature~~ ,~, KRYSTAL RODRIGUEZ OTERO l~ ~Notary Public-State of Florida §;, ;§ Commission, HH 89764 ~z,,_,,,...,1$ My Co a,miui,on E~pires I . . .G~v-0~ SYSTEM CAPACITY: 12.95 KW DC / 7.6 KW AC PV PANELS: (35) SIL-TITAN 370 NX (66 CELL) BY SILFAB OPTIMIZERS: (4) PV LINK BY GENERAC INVERTER: (1) PWRCELL 7.6 BY GENERAC RACKING SYSTEM: CROSSRAIL 44X BY K2 COVER SHEET C-1 1 PROJECT LATITUDE PROJECT LONGITUDE WIND EXPOSURE MIN AMBIENT TEMP MAX AMBIENT TEMP AHJ 30.344162 -81.410296 º C MAX WIND SPEED PROJECT DESCRIPTION C-1 COVER SHEET E-1 E-2 S-1 S-2 D-1 PV MODULES DATA SHEET GENERAL NOTES D 129 CITY OF ATLANTIC BEACH D-2 D-3 SMART MONITORING DATA SHEET INVERTER DATA SHEET RACKING PLAN SAFETY LABELS STRUCTURAL PLAN ONE LINE RISER DIAGRAM 35 1 º C MPH C-2 SAFETY PLANS ROOF PLAN VIEW / BOS LOCATION1N.T.S. LOCATION MAP / WIND ZONES2N.T.S. IRRADIANCE MAP3N.T.S. 3D RENDERING4N.T.S. DRAWINGS INDEX " P R O P E R T Y S I D E F A C I N G S T R E E T " PROJECT INFORMATION NORTH PV DISCONNECT PV STRING INVERTER #1 EXISTING ELECTRICAL METER OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC PER FL. STATUTE 377.705 (REVISED 7/1/2017), I RAFAEL A. GONZALEZ SOTO, P.E. 83104 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. APPLICABLE CODES: 2020 FLORIDA BUILDING CODE 7TH EDITION, ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES, FFPC 7TH EDITION, NFPA 2018, NFPA 70 AND NEC 2017. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2020 FLORIDA BUILDING CODE 7TH EDITION OR LOCAL GOVERNING CODE. ALL WIRING METHODS AND INSTALLATION PRACTICES SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (NEC) 2017, LOCAL STATE CODES, AND OTHER APPLICABLE LOCAL CODES. MEANS SHALL BE PROVIDED TO DISCONNECT ALL CURRENT CARRYING CONDUCTORS OF THE PHOTOVOLTAIC POWER SOURCE FROM ALL OTHER CONDUCTORS IN THE BUILDING. CONNECTORS TO BE TORQUED PER DEVICE LISTING, OR MANUFACTURERS RECOMMENDATIONS. NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING. REQUIRED SAFETY SIGNS AND LABELS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE, OR OTHER MECHANICAL MEANS, LABELS SHALL COMPLY WITH ARTICLE 690 VI OF THE NEC 2017 OR OTHER APPLICABLE STATE AND LOCAL CODES. SEE LABELS AND MARKING PAGE FOR MORE INFORMATION. RACKING ROOF MOUNT SYSTEM SHALL BE INSTALLED FOLLOWING MANUFACTURERS INSTRUCTION SPEC'S, INCLUDING ALL GROUNDING WEEB CLIPS, GROUND LUGS, AND RAIL SPLICE KITS FOR ELECTRICAL CONTINUITY. MECAWIND TOOL IS BASED ON THE C&C WIND LOADS FOR ENCLOSED BUILDINGS. DESIGN WIND PRESSURES ARE CALCULATED USING ASCE 7-16 EQUATION 30.6-1. ALL NOTES IN FIGURES ASCE 7-16 30.4-1 AND 30.4-2(A,B AND /67C) HAVE BEEN INCORPORATED. MEAN ROOF HEIGHT MUST BE LESS THAN 60 FEET. D-4 RAPID SHUTDOWN DATA SHEET 0 TL1:AN p O W E R N O R T H SAFETY PLAN C-2 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC NOTES: 1. INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME 2. INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF NEAREST URGENT CAR FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK NAME: LOCATION OF NEAREST URGENT CARE FACILITY ADDRESS: PHONE NUMBER: SAFETY PLAN1N.T.S. "P R O P E R T Y S I D E F A C I N G S T R E E T " 2 PV DISCONNECT PV STRING INVERTER #1 EXISTING ELECTRICAL METER L_ ______ I TITAN SOLAR POWER B2.1 C3.1 B2.2 B2.3 B2.4 B2.5 B2.6 B2.7 C2.8 C2.9 C3.1 C3.2 C3.3 C3.4 C3.5 C3.6 C3.7 C3.8 C3.9 A1.1 A1.2 A1.3 A1.4 A1.5 A1.6 A1.7 A1.8 A1.9 PV LINK OPTIMIZER #1 PV LINK OPTIMIZER #2 PV LINK OPTIMIZER #3 5 5 4 30A/2P 30A/2P 1 STRING #1 2 3 4 1 STRING #2 2 3 4 1 STRING #3 2 3 5 11 9 7 50A 8 15 12 40A 17 14 FUSED 200A 1313 16 13 JB 5 5 6 10 C4.1C4.1 C4.2 C4.3 C4.4 C4.5 C4.6 C4.7 C4.8 PV LINK OPTIMIZER #4 4 1 STRING #4 2 3 0(7(5 200A 1 #4 THWN-2 GROUND EXISTING UNDERGROUND SERVICE 240V/120V 200A BUS BAR 3 #2/0 THWN-2 INVERTER TOTAL OUTPUT: 32A SAFETY RATING (125%): 40A TOTAL PV SYSTEM OCPD: 40A MAIN BREAKER RATING: 200A BUS BAR RATING: 200A 120% BACKFEED RATING: 40A 5 LEGEND: 1 4 7 10 2 5 8 11 3 6 9 12 14 1513 16 2 #10 PV WIRE 1 #8 BARE WIRE GROUND 3/4" EMT CONDUIT 2 #10 THWN-2 1 #10 THWN-2 GROUND 3/4" EMT CONDUIT GENERAC PV LINK SUBSTRING OPTIMIZER S2502 PWRCELL7600A BY GENERAC REFER TO D-3 SHEET 2 #8 L1,L2 THWN-2 1 #8 THWN-2 NEUTRAL 1 #8 TWHN-2 GROUND 3/4" EMT CONDUIT EXISTING INTERIOR SUB-PANEL RATED FOR 200A CAT5 CABLE FOR RJ-45 CONNECTOR BREAKOUT ADAPTER GENERAC PWRCELL CT PV INTERCONNECTION POINT - LOAD SIDE UTILITY DISCONNECT FUSED RATED FOR 200A GENERAC SNAP RS801 GENERAC AUTOTRANSFER SWITCH RATED 200A 2 #2/0 L1,L2 THWN-2 1 #2/0 THWN-2 NEUTRAL 1 #4 TWHN-2 GROUND 1 1/2" EMT CONDUIT NEMA3R JUNCTION BOX (35) SIL-TITAN 370 NX (66 CELL) BY SILFAB REFER TO SHEET D-1 17 18 19 20 NOT USEDNOT USEDUTILITY ELECTRICAL SERVICE NOT USED 2 #6 L1,L2 THWN-2 1 #6 THWN-2 NEUTRAL 1 #8 TWHN-2 GROUND 3/4" EMT CONDUIT WIRE SIZES, QUANTITY & TYPE RACEWAY SIZE, TYPE, LOCATION & INFO.WIRE AMPACITY CALCULATIONS ADDITIONAL INFORMATION WIRE TAG CONDUCTOR QTY. SIZE & TYPE NEUTRAL QTY. SIZE & TYPE GROUND QTY. SIZE & TYPE RACEWAY SIZE & TYPE RACEWAY LOCATION RACEWAY HEIGHT ABOVE ROOF OUTPUT CURRENT 125% OF OUTPUT CURRRENT MIN OCPD WIRE DE-RATED CALCULATION DIST. VOLTAGE VOLTAGE DROP % CONDUIT FILL %WIRE RATING AMBIENT TEMP # OF COND. FINAL AMPACITY DC (BEFORE JB) DC (AFTER JB) AC (INVERTER TO METER) (2) #10 AWG PV WIRE (4) #10 AWG THWN-2 (2) #6 AWG THWN-2 N/A N/A (1) #8 AWG BARE COPPER (1) #8 AWG THWN-2 (1) #8 AWG THWN-2 NOT APPLICABLE 3/4" EMT CONDUIT 3/4" EMT CONDUIT UNDER ARRAY ABOVE ROOF EXTERIOR WALL 1/2" TO 3-1/2" 1/2" TO 3-1/2" "N/A" 15A 15A 32A 18.8A 18.8A 40.0A 20A 20A 40A 40A X 0.76 X 1 = 30.4 A 40A X 0.76 X 0.8 = 24.3 A 75A X 0.76 X 1 = 57.0 A 10 FT. 20 FT. 5 FT. 350V 350V 240V 0.11% 0.21% 0.1% 6.4% 8.1% 7.7% OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC ONE LINE RISER DIAGRAM E-1 3 ONE LINE RISER DIAGRAM1N.T.S. I (1 )#6 AWG THWN-2 ~ '~ V r '1 ~ J ) A A II -+ II . + II . + II . + I L.,_J L...,_J L.,_J I + II 7 +· u (/ l ,~ r---, ~~ j u ~ ) A G A 11 -+ II . + II . + II . + IL _+_J L_+_J L _+_JI . + II ~ ~ 7 +· u (/ [ l 9 ~ _J L, i1 _ I 11 ~ - - - ~ ~0-------1/ d 1/ l u /2 (/ 9 u l ~ to ) ~~0------ J (/ ii Q 11 -+ II . + II . + 11 . + I L..,_J L...,_J L..,_J I . + II o"~ 7 +· u (/ ;1 -- c{-o---,,_}~\ -------c{-'= ,; -' □ ' -~ u y ~}J J ~ "'\; r +J ) '----------" IJ' 11 =+II. + II . + II . + I . + II . + II . + II +· u (/ ~~ =i 0 j j j j 1 1 TITAN S O L A R P O W E R LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.13 (B) LABEL LOCATION: AC DISCONNECT, MAIN PANEL PER CODE: NEC 110.27 (C) OSHA 1910.145(f)(7) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL DO NOT DISCONNECT UNDER LOAD WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING: PHOTOVOLTAIC POWER SOURCE CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SYSTEM SHUTDOWN MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 690.15, NEC 690.13(B) WARNING SECOND SOURCE IS PHOTOVOLTAIC SYSTEM DUAL POWER SOURCE PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 32 A 240V MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) 480 VDC 20A INVERTER #1 240 V 60 HZ MAXIMUM AC POWER NOMINAL OPERATING AC FREQUENCY MAXIMUM AC CURRENT NOMINAL OPERATING AC VOLTAGE 7.6 KW 32 A MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION N/A 15 A LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.13 (B) LABEL LOCATION: MAIN SERVICES DISCONNECT, DC CONDUIT PER CODE: NEC 690.31 (G) (3) LABEL LOCATION: INVERTER PER CODE: NEC 690.53 LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.54 LABEL LOCATION: INVERTER PER CODE: NEC 690.52 LABEL LOCATION: MAIN SERVICE PANEL PER CODE: NEC 690.45(B)(5) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 705.12 (B)(3) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 705.12(B)(2)(3)(b) LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 690.33(E)(2) & NEC 690.15 (C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, MAIN PANEL PER CODE: NEC 690.56(C)(3) LABEL LOCATION: AC DISCONNECT POINT OF INTERCONNECTION PER CODE: NEC 690.56(C) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS LOAD SIDE SAFETY LABELS E-2 4 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC PV SAFETY LABELS DATA1N.T.S. [& ] ] [ ~ ~, r ~ [ ~ ] ----~] [.._____ ___ _ 0 --- TITAN SOLAR POWER N O R T H OBS OBS OBS OBS OBS PV STRING INVERTER #1 PV DISCONNECT EXISTING ELECTRIC METER ARRAY C TILT=20.14º AZIMUTH= 141º (SE) ARRAY A TILT=20.14º AZIMUTH= 231º (SW) ARRAY B TILT=20.14º AZIMUTH= 231º (SW) SOLAR MODULE - TYP. SEE D-1 ROOF MOUNTS LOCATED AT CENTER OF ROOF TRUSS - TYP. WOOD TRUSSES/RAFTERS LOCATION - INSTALLER MUST VERIFY IN FIELD 4' 4' A1.1 A1.9 B2.1 B2.7 C2.8 C2.9 C3.1 C3.9C4.1 C4.8 72.13" 39.4" SIL-TITAN 370 NX (66 CELL) NOTES: -INSTALL MID CLAMPS BETWEEN MODULES AND ENDS CLAMPS AT THE END OF EACH ROW OF MODULES. -ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORE THAN ONE FOOTING ON BOTH SIDES OF THE SPLICE. UL 1703 CERTIFIED MAX. DESIGN LOAD: 79.3 psf APPLIED WIND LOAD : 57.94 psf RISK CATEGORY ZONES 1 (PSF) PRESSURES SPAN (FT) MAX. CANTI- LEVER (IN) MAX. EXPOSURE CATEGORY ROOF SLOPE (°) ROOF TYPE ULTIMATE WIND SPEED DESIGN WIND SPEED mph mph PRESSURE ZONE: MEAN ROOF HEIGHT: PERIMETER WIDTH: KD KZT KH VELOCITY PRESSURE (q) = 0.60*0.00256* KHKZTKDV2 VELOCITY PRESSURE (ASD) EXTERNAL PRESSURE COEFFICIENT Z1 EXTERNAL PRESSURE COEFFICIENT Z2e EXTERNAL PRESSURE COEFFICIENT Z2r EXTERNAL PRESSURE COEFFICIENT Z3 0.7 0.7 0.7 0.7 -1.4 -2.0 -2.0 -2.0 TOTAL ROOF AREA sq.-ft sq.-ft TOTAL MODULES: TOTAL PHOTOVOLTAIC AREA: WIND LOAD (PSF): TOTAL WIND LOAD (LBS): TOTAL ROOF MOUNTS: TENSION FORCE PER MOUNT (LBS): INTERNAL PRESSURE COEFFICIENT 0.18 3 130 129 II D 20 HIPPED 1&2 23.15 4.0 0.85 1.0 1.111 24.14 2,825.44 35 690.18 -57.94 -39,989.03 137 -291.89 38.14 52.62 52.62 52.62 4 4 4 N/A 2r 2e - - - - ' ' ' " " " MATERIAL ROOF TYPE ARRAY EQUALIZATION FACTOR: a = 0.8 (PSF) INTERIOR PRESSURES (PSF) EXTERIOR PRESSURES 27.04 38.62 38.62 38.62 40.56 57.94 57.94 57.94 EXTERIOR EDGE FACTOR: E = 1.5 INTERIOR EDGE FACTOR: E = 1.0 - - - - - - - - ASPHALT SHINGLES 16 16 16 N/A WORST CASE MODULE: ZONE 2e: 100% -57.94(1.00) = -57.94psf OBS ROOF OBSTRUCTIONS PV MODULES TRUSSES OR RAFTERS ROOF MOUNTS ROOF SLOPE XX.X ARRAY # STRING # MODULE # & RAIL EXTERIOR PV MODULEEXT. STRUCTURAL PLAN S-1 5 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC STRUCTURAL ROOF PLAN & PV MODULES LAYOUT1N.T.S. SOLAR MODULE ROOF INSPECTION NOTE: PV MODULE IN LAYOUT IS CONSIDERED NON-EXPOSED AFTER COMPLYING WITH THE FOLLOWING STATEMENTS BASED ON ASCE7-16: -NO INDIVIDUAL PV MODULE IS MORE THAN 0.5(MEAN ROOF HEIGHT) AWAY FROM ROOF EDGE OR ANOTHER MODULE. -NO INDIVIDUAL PV MODULE IS MORE THAN 4 FT AWAY FROM ROOF EDGE OR ANOTHER MODULE. -INDIVIDUAL PV MODULE IS MORE THAN 1.5(MODULE LENGTH) AWAY FROM CLOSEST EXPOSED EDGE ASCE 7.16 - 29.4-7 DESIGNED WIND PRESSURES: p = qh (GCp)(E)( a) ROOF'S GENERAL NOTES: 1- CONTRACTOR/INSTALLER TO VERIFY ROOF CONDITIONS FOR PROPER INSTALLATION OF THE PV SYSTEM. 2- CONTRACTOR/INSTALLER TO NOTIFY THE OWNER IMMEDIATELY OF ANY ROOF DEFICIENCIES AND/OR REPAIR REQUIRED TO INSTALL THE PV SYSTEM. 3- EOR DOES NOT ASSUME ANY RESPONSIBILITY FOR THE INSTALLATION OF ANY PV SYSTEM ON DEFICIENT ROOFS. 4-CONTRACTOR/INSTALLER ASSUMES ALL RESPONSIBILITY TO INSTALL AS PER MANUFACTURER STANDARDS. WEIGHTED AVERAGE LEGEND & SYMBOLS ·-----. ■-- /--=-=- ~// -■--• - ---------- y----■----■ I ,■ t ~I ~ ------t--------i------',-------r----t-~lli 11 1 l Ii i [ i ~ ~ t 'T ci------------t~-------r--~----::1::::..._~-------, c---; - I 1 Gll :,... ~ 0 o.a 11'1 t.i E, m 0.6 ,Q. u.. > C: f .2 0.4 ... --=(. ID ,.. = 0.2 ftl ,a 0 ::I 111 I~ 0 TITAN SOLAR POWER - 1 ) " 10 . r ' ""~ .. __ 100 1000 1-----------------------1 2X4 RAFTERS 24" O.C. ASPHALT SHINGLES 2 ' ' C L E A R A N C E T Y P . 1/4" SS 18-8 BOLT 1/4" SS SERRATED FLANGE NUT <25 % M O D U L E L E N G T H T Y P . ATTACHMENT DIAGRAM 2 ROWS OF RAILS PER MODULE CROSSRAIL END CLAMP SEALANT L-FOOT 5/16" SS LAG BOLT 5/16" SS FENDER WASHER K2 SYSTEMS CROSS RAIL RT MINI NOTE: SEAL BASE MOUNT TO EXISTING ROOF UNDERLAYMENT WITH ROOF SEALANT AND MEMBRANE 6" TY P . "A" "A"SEE DATA SHEET ABOVE SHINGLE ROOF MOUNT DETAIL & DATA1N.T.S. SPAN TABLE FOR RT MINI ANCHORAGE SYSTEM DISTRIBUTED LOAD CALCULATIONS PV MODULES & RACKING WEIGHT = (INDIVIDUAL MODULE WEIGHT + 3.5 LBS) * (MODULE QTY) = (47.9 LBS) * (35) = 1,676.5 LBS PER SQUARE FEET (PSF) ARRAY LOAD = PV MODULES & RACKING WEIGHT / TOTAL ARRAY AREA = 1,676.5 LBS / 690.18 SQFT = 2.43 PSF HENCE, ROOF WILL CARRY THE ADDITIONAL SOLAR SYSTEM LOAD Lag Screw Installation Guidelines 1. Determine location for the Mount on roof by drilling through the center of truss from bottom with 5/32" drill bit. 2. Mark mounting holes for Mount on underlayment. Mounting holes should be centered on the trusses. 3. Drill 15/64" pilot hole. 4. Apply sealant to bottom of Mount. 5. Place Mount over roof underlayment with holes in roof. 6. Apply sealant to bottom of Mount, apply sealant to lag screws and fasten Mount securely to trusses. 7. Apply additional sealant to top assembly to be sure all penetrations are sealed. Notes: (1) Thread must be embedded in the side grain of a Trusses or other structural member integral with the building structure. (2) Lag Bolts must be located in the middle third of the structural member. (3) These values are not valid for wet services. (4) This table does not include shear capacities. If necessary, contact a local engineer to specify lag bolt size with regard to shear forces. (5) Install lag bolts with head ad washer flush to surface (no gap). Do nor over-torque. (6) Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessary. See table 10.3.1 in the American Wood Council NDS for Wood Construction. ASCE 7-16 Velocity Pressure qz10 = 0.00256Kz Kzt Kd V2 Where: qz10 = ASCE 7-16 velocity pressure evaluated at mean roof height (psf) Kz = velocity pressure exposure coefficient Kzt = topographic factor Kd = wind directionality factor V = basic wind speed (mph) from ASCE 7-16 maps referred to as ultimate wind speed maps in 2020 FBC. As an example, for an array having an area of 158.04 sq.-ft., the total uplifting (resultant) force acting on the array would be -39.1 psf x 158.04 sq. ft. = -6,179.364 lb. Knowing this resultant force, the design engineer can now determine the number of attachment points and the size of the mounting hardware necessary to safely carry this load. Live Loads: Live loads associated with photovoltaic systems are usually assumed to be distributed uniformly and are small, on the order of 4 psf or less. Uni-Rac Specs. Lag pull-out (withdrawal) capacities (lbs) in typical roof lumber (ASD) STAINLESS STEEL Lag screw specifications Specific gravity per inch thread depth 5 16" shaft, * Douglas Fir, Larch Douglas Fir, South Engelman Spruce, Lodgepole Pine (MSR 1650 f & higher) Hem, Fir, Redwood (close grain) Hem, Fir (North) Southern Pine Spruce, Pine, Fir Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) Sources: American Wood Council, NDS 2005, Table 11.2A, 11.3A. 0.50 0.46 0.46 0.43 0.46 0.55 0.42 266 235 212 235 307 235 205 0.50 266 Th r e a d de p t h Spruce, Pine,Per inch Thread Depth 266lbs SS Lag Bolt 5/16" x 4"Min. Thread Depth 0'-3" Wood Strength x Thread Depth = Pull Out Strength 266 lbs. x 3 in = 798 lbs. Allowable Pull Out Strength per Lag Bolt 798 lbs. Max. Pull Out Strength Required per Lag Bolt 291.89 Lag Bolt Pull Out Strength Safety Factor 2.73 LAG BOLT PULL OUT CALCULATIONS EQ.EQ. CL EXIST. 2X WD. TRUSSES OR RAFTERS SECTION "A-A" FLASHING LAG BOLT N.T.S. PLACE BOLT AT C.L. OF TRUSS OR RAFTER K2 SYSTEM 44-X Landscape 72-Cell Ground Snow Load Exposure Category Panel Angle Wind Speed 130 mph Roof Zone 1' 1 2e 2r 2n 3e 3r 0 psf D 7 to 20 Array Interior 71 71 71 62 62 62 57 Array Edge 62 62 62 51 51 51 47 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC RACKING PLAN S-2 6 We support PV systems Fnrm Arly F.vAT R"t;:;nlAr;:;y,,1Am«!i!" CIWSSl~AIL LILI-X Mechanic al Properties Ut,m(lteTi:ns ,leStren~th Sectio nal Propert ies A[X-Ser.tion] Units:[mm]in 37.7 ksi [260MPo] □.H9□i n3 [C.278 ~cm3) 0.H50in3(0.35a3cm3J 0.ll0S 0in2[1 .C23'i cm2 • Structurrn rnluos and sp an char rndot onlinod in occordancBv.ith Al uminurr Dosi~n Mamal rnd ~SCE 7-16 • UL27U:3Listc d::i1·ste 11torfirea11 dllev1dino We support PV systems FrrmArly F.vArA"t;:;nlAr;:;y,,tAm'l iei 0 0 0 0 ' o~- o---C o----l 0 ~ We support PV systems FrrmArlyF.vArA"t;;nlArSy"tAm'I!' • T g CrossRail End Clamp CrossRail Mid Clamp TECHNICAL SHEET Tl:Cl-11\ilCAL SHEET lt•ml.umtier nascrnx Technical Da ta S:ap~ of applicatio n FJste11lngtype/Roof fixture CJnpatiblemodulafromo s,ze ~O □OJ.J~g I CP EC Sil ver 3 □-S□m1'1, Shared P.L3D-I.J :imm 4U lJUll~ll I ~H EC Dark JU -SUmm, She!rE d RL :J[-i.J:C,mm MB 3cr ·atcd Flomyo H~;., Hc~d Bo lt..13mm ~000601-H ICR 1-iC Sitl-c1·30-~7mr1, l3mn He,; ~O □OS0 2-H !CR '-4~ Dark 30-1Omrr, 13 mrr He~ C11m~i::pr ing,3Srnmltmgth Mld ClclTl p S1a1o□ti Technical Dota CJ mpat ibl e module'ramesii ~ RT-MINI Flexible Flashing cert1f1ed by the International Code Council (ICC) Eng ineered to ASTM D 1761 (Standard-esl Melh:,d~fc-rl,llacl1anlcalF11.mm~111 nWood) Components Dimensions in (mm) RT2-00-MINIBK ♦--. Optional item ~,~:,□;,;: ~t:~~,:~:;~~~;~~~~~::~~:~J~: ea.'1Jag RT-Butyl (RT204 BLJTYLT)• 10 e~_,fux RT-Butyl is Roo"Tech 's fl exible flash ing used i n 700 ,UUOresi,jentia l PVsystems for thelast 24years 11 lsthe f irst PV m:iuntlng system wi th Flexible Fl as hing cer11fle::lbylhe IC C Mmlelas~ ,, ':"°'~ :lexib~e~ ; -- Rafter installation RoofT ech Inc ~ WWW roof-tech us 1nfo@roof-tech us ~~~s,~ 10620 Treena Stree1s5s"~fs2lg1;J"" Diego, CA 92131 /"~ fs, TITAN SO L AR POWER I I I We support PV systems FnrmArlyF.vATA .. t!>nlArSy .. tAffl'I ~ ~,,r J] + + L-Foot [n .n] ... TECl-il\llCAL SHEET Tech nic al Da ta [1111111 i,,ci,~~ Vi e d Strength • ,I.II K2 _-foul P.Kl,; leCcmp K L.anc ~lcll!Jd L-Foot ] hcl'e th~ s~rne e~trusion Q~umetr f/8. The3E compcne nt~ bohavc thc ~omc otn.Jc:1..n :il ly -l!'!n"lliou~ :mnrt t o liiffirulr <;u h<;tr,it·p~ PE r Tlanen:Lyflexible -~;t'~~i;~-~~e cpp 1 oval NGA 17-0329.18, I I I =i t t V PV MODULES DATASHEET D-1 7 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC Subject: Update to Silfab's UL 1703 Mechanical Load Test Ratings To whom it may concern, Silfab Solar Inc. 240 Courtneypark Drive East Mississauga, Ontario, Canada L5T 2Y3 Tel: +1-905-255-2501 Fax: +1-905-696-0267 Web: www.silfabsolar.com Email: info@silfabsolar.com February 10th , 2021 Thank you for your choice of employing Silfab PV Modules in your PV rooftop projects, some of which can be located in areas with above normal windload design requirements. Silfab Solar Inc. has made recent targeted efforts to extend the mechanical test load ratings under the UL 1703 PV module standard for Silfab's residential PV module product offerings with regards to extreme uplift design load needs, namely the PV modules identified as follows: SIL-xxxNL, SIL-xxxHL, SIL-xxxBK, and SIL- xxxNX . This letter serves to clarify the achieved maximum test load ratings, and the associated design load ratings, according to the following modifications to the design of the module's mounting locations under a 2-rail configuration which must be followed in order to ensure compliance: (i) (ii) SIL-xxxNL and SIL-xxxHL: the mounting/clamping locations must be made along the long edge of the module frame and be spaced apart 1100mm +/-25mm in a symmetric/centered fashion. SIL-xxxBK and SIL-xxxNX : the mounting/clamping locations must be made along the long edge of the module frame and be spaced apart 1200mm +/-25mm in a symmetric/centered fashion . As long as the design and installation of the aforementioned PV module types follows the guidelines above, the maximum test load ratings in both downward and upward orientation s have been confirmed as 119psf (5700Pa) which corresponds to a maximum design load rating of 79 .3psf (3800Pa). Jr~ ltai Suez, PhD -Vice President of Product Development Silfab Solar Inc. AOOOl Rev. D Sep. 3, 2019 Electrical S ec1ficat1ons SIL-370 NX mono PERC Test Conditions STC NOCT Module Power (Pmax) w 370 266 Maximum power voltage (Vpmax) V 37.2 33.7 Maximum power current (lpmax) A 10.0 7.9 Open circuit voltage (Voe) V 44.8 40.7 Short circuit current (lsc) A 10.6 8 .3 Module efficienc % 20.2 18.2 V 1000 Series fuse ratin A 20 Power Tolerance w +/-3% Measurement conditions: STC 1000 W lm2 • AM 1.5 • Temperature 25 °C • NOCT 800 Wlm' • AM 1.5 • Measu rement uncertainty~ 3% .. Sun simu la tor calibration reference modules from Fraun hofer Institute. Electrical diaract_er_ist_ics_m_a ... yv_a ..... ry-'by'-=-5_%_an_d :...po_we_r....;by_+_l-_3%_,. ----------------------~ Temperature Coefficient lsc Temperature Coefficient Vo e Temperature Coefficient Pmax NOCT (± 2°C) Oeerating temeerature Module wei ht Dimensions (H x L x D) Maximum surface load (wind/snow)* Hail im act resistance Cells Glass Cables and connectors (refer to installation manual) Backsheet Frame By pa ss diodes Junction Box Warranties Module product workmanship warranty Linear power performance guarantee Certifications Product Facto All states except California ill Modules Per Pallet: 26 i!! Pallets Per Truck: 34 m Modules Per Truck: 884 California ill Modules Per Pallet: 26 Hi Pallets Per Truck: 32 m Mod ule s Per Truck: 832 * A Warning. Read the Safety and Insta llati on Manual For mounti ng specifications and before han dli ng, insta lli ng and operating modules. ''12 yea r ex tendable to 25 years subject to reg is trati on and cond i- tions outlined under"Warranty" at www.s ilFab so la r.com. '**Cert 1ficat1 on and CEC listing in progress. PAN files generated from 3rd par ty pe rforma nc e data are available for download at: www. si lfabs o la r.co m/d ow nloads. Titan So lar Power 525 W Base lin e Rd Mesa ,Af 85210 Tel 855 SAY -SOLAR Titanso la rpower.com info@)tita nsolar power Si lfa b So lar In c. 240 Courtneypa rk Drive East Mississauga ON L5T 2Y3 Canada Tel +1905-255-2501 I Fax +1905-696-0267 info@)silfabso lar.com I www.silfabso lar.co m Silfab So lar In c. 800 Cornwa ll Ave Bellingham WA 98225 USA Tel +1 360-569-4733 TITAN SOLAR POWER SIL-370 NX mono PERC 0.064%/°C -0.28 %/°C -0 .36 %/°C 46°C -40/+85 °C SIL-370 NX mono PERC 44±0.4 lbs 72.13 in x 39.4 in x 1.5 in 83.5/112.8 lb/ft"2 0 1 in at 51.6 m h 66 -Si mono -PERC -5 busbar, 62.25 x 62.25 in 0.126 in hi h transmittance, tern ered, DSM anti -reflective coa ti 47.2 in, 0 0.22 in, MC4 from Staubli Hi h durabili , su erior h drol sis and UV resistance, multi -la er dielectri c film, Auorine -free PV backsheet Anodized Aluminum (Black) 3 diodes-30SQ045T (45V max DC blocking volta e, 30Amax forward rectified current) UL3730 Certified, IEC 62790 Certified, IP67 rated SIL-370 NX mono PERC ;:,, 97.1% end 1~ ear ;:,, 91.6% end 12th ear ;:,, 85.1% end 25th ear ~ 82.6% end 30th ear SIL-370 NX mono PERC ULC ORD C1703, UL1703, CEC listed"', UL 61215-1/-1-1/-2 , UL 61730 -1/-2, IEC 61215-1/-1-1/-2***. IEC61730-1/-2'*', CSA C22.2#61730-1/-2, IEC 62716 Ammonia Corrosion; IEC61701:2011 Salt Mist Corrosion Certifed, UL Fire Rating: Ty pe 2 ISO9001:2015 38 ,11" [968mm] 39.3 7" [1000mm] 1.5" (38mm( 1 1 SMART MONITORING DATASHEET D-2 8 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC PV Link™ 2500W MPPT Substr ing Optimizer Model: APKE00010 Certification Mode l Reference: S2502 PV Link is the simple solar optimizer for quick installation and long-lasting performance. Connect as few as two or as many as nine PV modules to each PV Link to overcome shad ing and challenging roof lines. ADDITIONAL FEATURES Quick connections w ith MC4 connectors 2500W capacity Compat ib le w ith high-vo ltage smart batteries Cost-e ffective so lution for high-p erformanc e PV Ground -fault protection Generac PWRce ll Invert er GENERAC" Generac PV Link Single-string PV Array with Generac SnapRS'" devices SnapRS devices (RS) installed to negat-,e (-) whip of each PV module. RS Generac Power Systems. Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1-888-GENERAC (1-888-436-3722) Specifications [;,;y [YRl3 ~ RATED POWER 2500 W PEAK EFFICIENCY 99% MPPT VOLTAGE RANGE 60-360 VMP MAX INPU T VOLTAGE 420 VOC; max when cold MAX OUTPUT 420 voe NOMINAL OUTPUT (REBUS ·) 380 VDC MAX OUTPUT CURRENT BA MAX SHORT CIRCUIT 18A CURRENT (ISC) STANDBY POWER <1W GENERAc· TITAN SOLAR POWER M ' I PROTECTIO NS Ground-fault, Arc-fau lt (Arc-fault Type 1 AFCI, Integrated) MAX OPERATING TEMP 70 °( SYSTEM MONITORING ENCLOSURE WEIGHT DIMENSIONS (L,W.H) COMPLIANCE WARRANTY PWRv iew Web Portal and Mobile App Type 3R 7.3 lb 2" X 15.4 " X 9.6" UL 1741, CSA 22.2 25 Years Specifications subject to change without notice. Genemc Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha , WI 53189 www.Generac.com 1-888-GENERAC (1 -888-436-3722) Part No. A0000528162 REV A INVERTER DATASHEET D-3 9 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC GENERAC9 PWR 7.6kW 10 PWRcell Inverter Wl l h CTs Model II. X7602 (Ordering SKU. APKE00014) 11.4 kW 30 PWRcell Inverter with CTs Model 11 · X11402 (Ordering SKU: APKE00013 CELL GENEAAC PWR I Solar+ sto rage is simple with the Generac PWR cel l'" Inver te r. This bi-direct ional , RE b us"'-p o wered inverter offers a simple, efficien t d esign for integrating smart batt eries w ith solar. Ideal for self-supp ly, backup power, zero -export and energy cost management, the PWRcell Inverter is t he industry's most featu re-r ich line of inverters , ava ilable in single-phase and th ree-phase models. FEATURES & BENEFITS • Sing le inverter for grid-tied solar with smart battery integration • Simplified system des ign: No autot ransfo rmer or battery inverter needed • User-se le ctable modes for backup power, self-supply, time-of-use, zero-impo rt and export limiting • Free system monitoring inclu d ed via PWRview™ Web Po rta l and Mobile App MAX. CONT. GR ID·TIED AC POWER @ so ·c (122 °F)· AC OU TPUT VOLTAGE : AC FREQUENCY: MAXIMUM CONTINUOUS OUTPUT CURRENT : GROUND -FAULT ISO LAT ION DETEC TION: CHARGE BIITTERY FROM AC : THO (CURRE NT): TY PICAL NIGHTTIME POWER CONSUMPTION: MAX . CONT. AC POWER @ 40'C (104 "F) W/ SINGLE 6 MODULE BATTERY CAB INET ': MAX . CONT . AC POWER @ 40'C (104 "F) WITH 2 BATTERY CAB IN ETS (8 MODULES MINIMUM): MAX . CONT. AC POW ER @ 50"C (122"FI: PEAK MOTOR STARTING CURRENT (2 SEC): AC BACKUP OUTPUT VOLTAGE: AC FREQUENCY: 7600W 1201 240 , 10 VAC 60 Hz 32 A, RMS In cluded Yes <2% <7W 9,000 W 11,000 IV 8 .800 W 50 120/240, 10 VAC 60 Hz 11400 W DC INPUT VOLTAGE RANGE : 12 01208, 30 VAC NOMINAL DC BUS VOLTAGE : 60 Hz DC DISTR IBUT ION INPUT BREAKERS : 32 A, RMS MAX INPUT CURR ENT PE R DC INPUT: In cluded REVERSE -PO LAR ITY PROTEC TION : Yes TRANSFORMER LESS. UNGROUNDED · <2% TYPICAL NIGHTTIME POWER CONSU MPTION : <7W DC BUS EXPOR T FUSES(+/·): 2-POLE DISCO NNE CT ION : 9,000 W PEAK EFFICIENCY : 9.600 -11 .000 W' CEC WEIGHTED EFFIC IENCY : 7,500-8,800 W' , RMS 12 01208 , 10 VAC 60 Hz 'Peak Performance 360-420 VDC 380 VDC 4 x 2P30 A 30 A Yes Yes <7 W 40 A Yes 97 .3% 96.5% lntertek 360-420 VDC 380 VDC 4 x 2P30 A 30 A Yes Yes <7 W 40 A Yes 97 .7% 97.5 % THO (VOLTAGE): <2% AUTOMAT IC SW ITC HOVER TIME: < 1 Seco nd s <2% < 1 Seco nd s 21n Island mode X11402 protected loads only supply 2 phases 120 VAC L-N, 208 L-L which results In lower power thon in grid tied 3 phase mode. The low value of the range Is for full L-L loading whlle high value of the range is full L•N loading Specifications FEATURES AND MODES ISLANDING 3: GR ID SELL: SELF CONSUMPTION : PR IORIT IZED CHARGING FROM RENEWABLES: GR ID SUPPORT -ZERO EXPORT: ESS PCS OPERATION MODES (IMPORT ONLY, EXPORT ONLY): ADDITIONAL FEATURES SUPPOR TED COMMUN ICATION INTERFACES: SYSTEM MONITORING BACKUP LOADS DISCO NNEC P: IN VERTER BYPASS SW ITC H: WARRANTY : STANDARDS COMPLIANCE SA FETY: GR ID CONNECT ION STANDARDS: EMISS IONS: DIMENSIONS AND INSTALLATION SPECIFICATIONS ENCLOSURE KNOCK OUTS -QTY, SIZE -IN (MM): DIMENSIO NS L x W x H -I N (MM): WE IGHT · LB (KG): COOLI NG: AUDIBLE NOISE: OPE RATING TEM PERATURE -FAHRENHE IT (CELSIUS ): PROTECTION RAT ING INSTALLATION GUIDELINES BATTERY TYPES SUPPORTED: MODULE STRING SIZE PER PV LI NK OPT IMIZER: MAXIMUM RECOMM ENDED DC POWER FROM PV: 330 inverters offer islanding for 10 loads. Yes Yes Yes Yes Yes Yes REbus ~, CANbus, Et hernet PWRview '" Web Portal and Mobile App Yes , 50 A Circui t Breaker Auto mat ic 10 Years UL 1741 SA , CSA 22.2 , UL 1998 IEEE 15 47, Rule 21, Ru le 14H , CS IP, UL 1741 PCS CRD (Import Only, Expo rt Only) FCC Part 15 Class B 6 x Combo 3/4" x 1" (19 x 25.4) 7 x Combo 1/2" x 3/4" (12.7 x 19) 24.5" X 19.25 " X 8" (622.3 X 488.9 X 203.2) 62.7 (28 .4) Forced co nv ec t ion < 40 dBA -4 to 122 °F (-20 to 50 °C)' NEMA 3R PWRcel lN Battery Var ies , refer to PV Link Installa tio n Manual 15 kW 'Includes ambient temperature rising from inverter operation. Reduced power at extreme temperatures. Sp ecifications listed in this document are achieved with firmware version 13310 or greater. Confirm invertE!r has lo test firm wort? to ensurE! full performancE!. Generac Pow er Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1888-GENERAC (436 -3722) A0000528185 REV E ©2020 Generac Powe r Systems. Al l righ t s re served. Specifications are subject to change without notice. TITAN SOLAR POWER GENERAC® - RAPID SHUTDOWN DATA SHEET D-4 10 OF 10 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 (813) 982 -9001 #EC13008093 CONTRACTOR CONTACT INFORMATION REV DESCRIPTION CONTRACTOR LOGODATEENGINEERING STAMPENGINEER CONTACT INFORMATION C.A. 32661 255 GIRALDA AVE CORAL GABLES, FL 33134 DESIGN@ENGIPARTNERS.COM 833 - 888 - 3644 JASON SEBESTOS 07-27-2021 1710 MARITIME OAK DRIVE ATLANTIC BEACH FL 32233 SHEET TITLE: SHEETS: ENG. RAFAEL A. GONZALEZ SOTO, PE SHEET NAME: PROJECT ADDRESS: CUSTOMER: ENGINEER OF RECORD: DATE: 19514-00087 PARCEL NUMBER: PROJECT ID: TSP86693 DOCUMENT CONTROL 08-05-2021 ENGIPARTNERS LLC TITAN SOLAR POWER FLISSUED FOR PERMIT CAD QC KC JG DATE CAD QC GENERAC® SnapRS™ In line Disconnect Switch Model: APKE00011 Certification Model Reference: RS801 Generac Snap RS are a simple way to satisfy rapid shutdown compliance for solar+ storage systems . Generac Snap RS are 2017/2020 NEC 690.12 compliant, don't require any extra hardware to mount, and need no pairing or fussy digital communications. FEATURES & BENEFITS • Fast, easy, and simple to install • One SnapRS device per PV module • Achieves PVRSS Compliance • Low cost, high efficiency solution SYSTEM DESIGN Snap a Generac SnapRS disconnect device (RS) to the negative lead(-) of each module in the solar array for simple module-level rapid shutdown compliance. Snap RS devices isolate array voltage when a rapid shutdown is initiated at a PWRcell '" Inverter. When rapid shutdown is initiated , SnapRS units isolate each PV module in the array, reducing array voltage to <80V in seconds . PWRcell Inverter PV Link RS c@us l.1srEO lntertek RS Diagram is applicable for most 60 cell PV modules. Modules w ith higher cell c ount may require a different arrangement. Contact Generac for more details. S ·,· • ~ pec11cat1ons Snap RS • (APKE00011) PV MODULE MAX voe: 75 V EFFICIENCY: 99 .8%* MAX INPUT CURRENT: 13 A SHUTDOWN TIME: < 10 Seconds ENCLOSURE RATING: NEMA 6P OPERATING TEMPERATURE --40 to 158 °F FAHRENHEIT (CELSIUS): (-40 to 70 °C) CERTIFICATIONS: UL1741 PROTECTIONS : PVRSE WEIGHT -LB (KG): 0.17 (0.08) DIMENSIONS , L x W x H -IN (MM): 7" X 1" X 1" (177.8 X 25.4 X 25.4) WARRANTY: 25 Years *When used with a SOV panel Connect one Sn ap RS device to the negative lead of each PV modu le in the PV Link controlled array for complete PV Rapid shutdown performance Generac Power Systems, Inc. 545 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1888-GENERAC (436-3722) A0000528183 REV C ©2020 Genera c Power Sys tems . All rights rese rved. Specificat i ons are subject to change without notice. TITAN SOLAR POWER GENERAC® -