336 12th St ROOF21-0074 Metal RoofOWNER:ADDRESS:CITY:STATE:ZIP:
BODGE KEVIN R 336 12TH ST ATLANTIC BEACH FL 32233-5514
COMPANY:ADDRESS:CITY:STATE:ZIP:
WOFFORD ROOFING &
WATER PROFING 2933 W. Southern Hills Cir JACKSONVILLE FL 32225
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
171926 0000 SELVA MARINA UNIT 01
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
336 12TH ST ROOF NON SHINGLE METAL ROOF $76500.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $388.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $194.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 BUILDING BUILDING OFFICIAL NOTES INFORMATIONAL
Notes:
BUILDING OFFICIAL NOTES
In-progress inspection required-dried in
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 9/30/2021
PERMIT NUMBER
ROOF21-0074
ISSUED: 9/30/2021
EXPIRES: 3/29/2022
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
STATE DBPR SURCHARGE 455-0000-208-0700 0 $8.73
STATE DCA SURCHARGE 455-0000-208-0600 0 $5.82
TOTAL: $596.55
2 of 2Issued Date: 9/30/2021
PERMIT NUMBER
ROOF21-0074
ISSUED: 9/30/2021
EXPIRES: 3/29/2022
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $596.55
ROOF21-0074 Address: 336 12TH ST APN: 171926 0000 $596.55
BUILDING $388.00
BUILDING PERMIT 455-0000-322-1000 0 $388.00
BUILDING PLAN REVIEW $194.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $194.00
STATE SURCHARGES $14.55
STATE DBPR SURCHARGE 455-0000-208-0700 0 $8.73
STATE DCA SURCHARGE 455-0000-208-0600 0 $5.82
TOTAL FEES PAID BY RECEIPT: R17419 $596.55
Printed: Thursday, September 30, 2021 8:55 AM
Date Paid: Thursday, September 30, 2021
Paid By: WOFFORD ROOFING & WATER PROFING
Pay Method: CREDIT CARD 518101680
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R17419
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
8
Se
p
t
e
m
b
e
r
2
0
2
1
J
e
r
o
d
W
o
f
f
o
r
d
X
RO
O
F
2
1
-
0
0
7
4
ROOF21-0074
5 V CRIMP Panel over Plywood
Florida Building Code 2017 6th ed.
Compliance: Per Rule 61G20-3 Method: 1-D
Category: Roofing -Subcategory: Metal Roofing NON-HVHZ
9450 AJysbury Place
Montgomery, AL 36117
Premier Metal
17613 South Hwy. 475
Summerfied, FL. 34491
352-356-1609
Engineer Validator
Diane Marotta, P.E.
555 Prospect Road
Oakland, FL 33309
Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code
Product Description:
Material:
Panel Dimensions:
Fastener: 2017
Section 1506.7.
26ga steel 49ksi conforming to Florida Building Code 2017 Section 1507.4.3
Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section
1507.4.3 Panel Widths: 24” width panels Rib height: THRU FASTENED *see install details.
#10 X 1-" Hi Lo HWH fastener w/weather seal washer Corrosion Resistant per Florida Building Code
1/4" minimum penetration through bottom of plywood . Plywood supports at maximum 24' O.C.
Design of plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017.
Minimum Slope :
Installation:
Underlayment:
Fire Classification:
Shear Diaphragm:
Design Procedure:
Range Slope per Florida Building Code 2017 6TH ed., in accordance with Manufacturers recommendations.
Install per manufacturer's recommended details.
Per Manufacturer's installation guidelines per Florida Building Code 2017, CHAPTER 1507, CHART 1507.1.1
Classification not part of this report.
Values are outside the scope of this report.
Based on the dimensions of the structure, applicable wind loads are determined using Chapter 16 of the
Florida Building Code 2017 for roof cladding wind loads. These component wind loads for roof cladding are
Compared to the allowable pressure listed above. The design professional shall select the applicable
erection details to reference in drawings for correct fastener attachment to his structure and analyze the
panel fasteners for pullout and pullover. Support framing must be compliant with Florida Building Code
2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
Florida Product Approval # FL 30343
Locke Bowden, P.E.
FL # 49704
over 15/32" APA Plywood decking over supports @ 24” O.C. Non-structural Application.
2017 6th ed., Sections 1504.3.2, 1507.4.3, 1507.1.1
5 V CRIMP Panel, 24" Wide. 3/8" rib height panels restrained with fasteners
Engineer Evaluator
Locke Bowden, P.E.
_______________________________________________________________________________________
ROOF21-0074
Design Uplift Pressures: Uplift Design Pressure: with Safety Factor of 2
-82.25psf 9-9-9-9 FASTENING PATTERN 24" O.C.
-123.5psf 9-9-9-9 FASTENER PATTERN 12"O.C.
___________________________________________________________
INTERTEK Test References: I4625-450-44-R0
UL 580-06-Test for Uplift Resistance of Roof Assemblies
Integrity Metal authorizes sharing this report.
Certificate of Independence: Locke Bowden, P.E. does not have nor will acquire financial interest in any company
manufacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned or operated or
controlled by any company manufacturing or distributing product under this report.
INSTALL DETAILS PER MANUFACTURER'S DETAILS AND IN ACCORDANCE WITH FBC 2017.
_____________________________________________________
______________________________________________________
1.Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.. see Chart 1507.1.1
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer’s installation reference.
3.Products are compliant with State of Florida product approval per Rule 61G20‐3. Compliance Method: 1‐D
4.Engineering analysis for “project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5.Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6th ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
LIMITATIONS
Allowable Design Pressure -63.5psf or -86psf DESIGN PRESSURE SAFETY MARGIN 2:1
16" o.c. 12" o.c.
Fastenen at each seam and intermediate ribINSTALL DETAILS: