Loading...
348 Aquatic Dr RES21-0298 Siding �i-�vi,.% RESIDENTIAL PERMIT PERMIT NUMBER [' \51 RES21-0298 ;-• yr CITY OF ATLANTIC BEACH ISSUED: io/1/lou 1 800 SEMINOLE ROAD ---t. ' ATLANTIC BEACH. FL 32233 EXPIRES: 3/30/2022 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 348 AQUATIC DR RESIDENTIAL SIDING REPLACE T1-11 WITH HARDI $2000.00 LAP SIDING TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 171818 5116 AQUATIC GARDENS COMPANY: ADDRESS: CITY: STATE: ZIP: OWNER: ADDRESS: CITY: STATE: ZIP: ONEILL ROBERT W JR 327 PLAZA ATLANTIC BEACH FL 32233-5441 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. BUILDING IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: IN-PROGRESS INSPECTIONS ARE REQUIRED FOR EXTERIOR SIDING,WINDOW,AND DOOR INSPECTIONS,AND SHOULD BE SCHEDULED FOR THE FIRST DAY OF WORK. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $65.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $32.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 Issued Date: 10/1/2021 1 of 2 01-41-1- .. RESIDENTIAL PERMIT PERMIT NUMBER A A . 0 RES21-0298 ! CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ISSUED: 10/1/2021 f 9 ATLANTIC BEACH. FL 32233 EXPIRES: 3/30/2022 STATE DCA SURCHARGE I 455-0000-208-0600 0 $2.00 TOTAL:$101.50 Issued Date: 10/1/2021 2 of 2 JOB COP" REVIEWED FOR CODE COMPLIANCE. rei'''?-- Building Permit Application u `' City of Atlantic Beach Building Department REVIEWED 800 Seminole Road, Atlantic Beach, FL 32233 By Mike Jones at 8:46 am, Sep 29, 2021 2Plhone: (904) 247-5826 Email: Building-Dept@coab.us ) (�� �2 Job Address: l l$ AA0-1 iL P -W g Permit Number; ��Z I - t�z 1 C w-� z -1I� k o o k G ' o HC- Legal Description t f v" 3 S - �( 17. E-2.9 RE# 1 f i C)!0 J 1 ((,/7 Valuation of Work(Replacement Cost)$ 2O0.00 Heated/Cooled SF _ Non-Heated/Cooled__. • Class of Work: ❑New ❑Addition DAlteration F ��( Move ❑Demo ❑Pool UWindow/Door • Use of existing/proposed structure(s): ❑Commercial P'1Residential • If an existing structure,is a fire sprinkler system installed?: ❑Yes C94o , • Will tree(s)be removed in association with proposed project? LiYes(must submit separate Tree Removal Permit) Iglo Describe in d ai(the type of work to be performed: C1i7" O ,6'17G,' OF /747-04 i/fl ! ted 1.1-e w trk, � put wiD� ov - cv t /tok S0 we4er + }"�p> `fr 1/P y t4 4-1"0-d Al As f/N1 Site) El—r- 210,12-. -- Florida Product Approval tt / Z ,I o for multiple products use product approval form Propertx Owner Information i �/ 'n"t 1A.' eim iL)' Address 3V8 1// ry� /'e Dr' Name 013 City R tlAtir/L f3.01-t State , Zip 3223 3 Phone (9: 27-- 7429 E-Mail P r! - J I c • 1.Lvnk Owner or Agent(If Agent, Power o'Attorney or Agency Letter Required) Contractor Information Name of Company lid/040144eriLQualifying Agent Address City State Zip Office Phone Job Site Contact Number State Certification/Registration# E-Mail /r/-. Architect Name&Phone# _-_ _______ --- Engineer's Name&Phone f_ / Workers Compensation Insurer - OR Exempt 0 Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS, POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECOR NG YOUR NpTICE OF COMMENCEMENT. /-;-( /- ,,,, - (Signature of Owner or Agent) (Signature of Contr tor) Signed and sworn- to(of affirmed)before me this/ da of Signed and sworn to(or affirme. ••efore me this day of ��207 t7J? by_ Ii e _�tt-�� 'i 'by - Z...'14,."! .."\. ERIN MA' E STEHL(Sig '1°1 'o . V) (Signature of Notary) My COMMISSIO' #GC 266132 •c {.,r EXPIRES pctober 14.2022 `ferstmall Known OR i J [ I Personally Known OR it-ro lice. ...n i i a i -i [ ]Produced Identification Type of Identification: L ___-____ — Type of Identification: _ JOP COPY Owner Builder Affidavit **ALL INFORMATION HIGHLIGHTED IN - City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: RES21-0298 I. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING" REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7), FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY, TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF $25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE,THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE,WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE,THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. . III. IRS WITHHOLDING;OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES.OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO. 455-228(1). AN "OCCUPATIONAL LICENSE" IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY"CERTIFICATE OF COMPETENCY" OR THE FLORIDA"CONTRACTORS CERTIFICATE"TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. CONTACT THE BUILDING DEPARTMENT(904- 247-5826 OR BUILDING-DEPT@COAB.US) IF IN DOUBT. V. ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. Job Address: gY8 u/'n'G ),/kir Owner Name: 1U,6JAT �' /A"41w PhonePh� Number:(0 2. 7-34 2- Mailing Address: '! e AQ4'4 C i2l(i 1i" City:MAO /( /OM State: ft- Zip: 322-53 Notarized Signature of Owner `-e �/ TThe e ngksytument was acknowledged before me this g2day ofy_ / , 20c2/in t State of Florida, County (---) Signature of Notary Pu is_ t f,:°` T'•. ERIN MARIE STEHI My COMMISSION x GG 166181 I I Personally Known R oduucced Identification '.' -t r./PIRES October 11.2022 ,\ 4 Type of Identification: Updated 10/24/18 • JOB COP" REVIEWED By Mike Jones at 8:47 am, Sep 29, 2021 Florida Product Approval HardiePlank® Lap Siding • For use inside HVHZ: HardiePlank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami-Dade County Florida NOA 07- 0418.04. Consult the HardiePlank product installation instructions on the follow pages for all other installation requirements. • For use outside of HVHZ, HardiePlank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2298-11 or RIO-2300-11. Consult the HardiePlank product installation instructions on the follow pages for all other installation requirements. JOB COPY HardiePlank®/�Z- JamesHardie 1� Lap Siding EFFECTIVE NOVEMBER 2010'. INSTALLATION REQUIREMENTS-PRIMED&COLORPLUS PRODUCTS visit ywrlginx,stiailie,com to me must recent version. SELECT CEDARMILLL-SMOOTH•COLONIAL SMOOTH®•COLONIAL ROUGHSAWN®•BEADED CEDARMILL© BEADED SMOOTH-STRAIGHT-EDGE SHINGLE PLANK IMPORTANT:FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY,AFFECT SYSTEM PERFORMANCE,VIOLATE LOCAL BUILDING CODES,AND VOID THE PRODUCT ONLY WARRANTY.BEFORE INSTALLATION,CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONETM PRODUCT INSTRUCTION&. INSTALLATION OF HZtO®PRODUCTS OUTSIDE AN HZ10®LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONETM'APPLIES TO YOUR LOCATION,VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343(866 9HARDIE) STORAGE& HANDLING: m CUTTING INSTRUCTIONS Store fiat and keep dry and oumoonS 0400010 covered prior to installation.Installing l Pc bon lallrg state so eel rind v4I dow dost aver limn kee 1 (lit My using Score ad snap.a Sheets Irraud,electric a pneumatic). and taus n wvtig aea 2 Poshirn n1tng statin m we*ventiWfed area siding wet or saturated may result in 2.Use ere d Ile toiumrg metals shnrtkage at butt joints.Carry planks a Best h Score and snap e Seers(nan (dalrk a actuate) NEVER use a power saw indoors on edge. Proted edges and corners b.Bela: L Dust axiom cicala saw epurr{nd reel a -NEVER use a circular saw blade that does not cry the Itineiefkale saw blade tradenurk from breakage.James Hardie is not l lend Blade saw bade and IPPA maw em-adm NEVER dry sweep-Use wet sumwessim or HEPA Vacuum responsible for c Good i Dust reAuQd h rg data saw viti a harada saw)lade ; (my use la low tondo-4e attain) damage caused I by improper `, icor moan!Me far maarun adman Pawed rtsprable dad erodumoni,Ares Hartle maenads eAvays using lied'level cutting nemod Mere feesrhte Storage and ) hA631-arixtwe1 resetaas can be used n calm:trn vial atom ailing practwes to tutu rattle dust exposures Addend Paiposre information is amiable a wwwJarestiade.com to help you delarrita the most appropde olinll melted la you pb requirements.I ratan sti eels about exposure levels a you handling of the product it not cram eft net above pac4om.you staid*sem mar a qualified ndatrial r reglad a=tact James Flank kw hulee donna= GENERAL REQUIREMENTS: • HardiePlank"lap siding can be installed over braced wood or steel studs spaced a maximum of 24"o.c.or directly to minimum 7/16"thick OSB sheathing. Irregularities in framing and sheathing can mirror through the finished application. • HardiePlank"lap siding can also be installed over foam insulation/sheathing up to 1"thick.When using foam Insulation/sheathing,avoid over-driving nails (fasteners),which can result in dimpling of the siding due to the compressible nature of the foam insulation/sheathing.Extra caution Is necessary if power-driven nails(fasteners)are used for attaching siding over foam insulation/sheathing. • A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements.James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap"Weather Barrier,a non-woven non-perforated housewrapl,which complies with building code requirements. • When installing James Hardie products all clearance details in figs.3,4,5,6,7,8,&9 must be followed. • Adjacent finished grade must slope away from the building in accordance with local building Figure 1 Douce Walt Single Wall codes-typically a minimum of 6"in the first 10'. Cebu Construction • Do not use HardiePlank lap siding in fascia or trip applications. wiser-resetue weer let tracing • Do not install James Hardie products,such that they may remain in contact with starling water. �a 24'o c man • HardiePlank lap siding may be installed on flat vertical wall applications only. `_0" �'�""g ir--• For larger projects,including commercial and multi-famiy projects,where the span of thewall is significant in length,the designer and/or architect should take into consideration i —`� the coefficient of thermal expansion and moisture movement of the product in their design These values can be found in the Technical Bulletin"Expansion Characteristics of James Hardie`Siding Products"at wrwv.JamesHardie.com.• DO NOT use stain on James Hardie`products. INSTALLATION: JOINT TREATMENT•(Required fa CdarRus+'Finish,Recommended(r Primed produ tJames Hardie does not recommend the use of caulk at feld bum pmts 11/ vc erresrstive s'a Install factory finished edges Figure 2 Owner '= together at butt joints 1 kat / de° 7.1,g T ow* /it/ . �M „,ng_ rn2ter�eerstne mstall planks m ■h :.'_- on // bourder moderate contact I °u r°, ° o /en fastener .-- 'p° Instal a 1 1:4'staler stip to ° • ensure a consistent plank angle 'Fir other jointing options refer to local building code or NER 405 "As required by local buffing code "'Apply caulk in accordance with caulk manufacturers written application insbucbons. bare appropriate gap between 'For additional information on HardeWrap"Weather Barney,consult James Hardie at 1.1366.4Harche or emir ardi bee/rap Com 1>lafis and trim then caulk . WARNING:AVOID BREATHING SILICA DUST James Harks•products contain respirable crystalline silica.which is known to the State of Ca torn to cause cancer and is considered by IARC and NIOSH to be a cause of cancer tom some ocorpabonal sources Breathing excess.*amounts of respirable silica dust can also cause a disabling and parentally fatal brig d sease rased shicots,and has been lurked with other diseases Some terries suggest smoking may increase these risks During etstaaation or handlnq(1)work in outdoor areas wit ample ventilation(2)use fiber cement shears for Cutting or.where not feasible.use a Haidiel34de saw blade and dust-reduarq°netar saw attached to a NEPA vacuum.(3)warn others in the immediate area.(4)wear a property-feted.NIOSH-apreoved dust mask or respirator(e g N-95)at accordance with appkcable government regrlabons and manufacturer instructions to further ten respirable slew e*posures During dean-up,use NEPA vacuums or wet deenup methods-neva dry sweep For further Womack refer to ou instaaaoon aakucbpns and Maternal Salety Data Sheet amiable al www iamesharde corn or by calling I-800-9HARDIE(1 a0O-942 7343) FAILURE TO ADOIERE TO OUR WARNINGS.MSDS,AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH HS092U-P114 10/10 JOB COPY yI = CLEARANCESAt the juncture of the roof and vertical Install siding and trim products in compliance Maintain a 1'-2'clearance between surfaces,flashing and counterflashirg shall with local building code requirements forJames Hardie nP ts and decking be instAled per the roofing manufacturer's clearance between the bottom edge of theMaintain a 1"-2'clearance material instructions.Provide a 1"-2"clearance siding and the adjacent finished grade. between James Hardie' iwire 5 between the roofing and the bottom edge of products and paths.steps IT the siding and trim. Figure 3 s,a,,,g t .race gll stud and dnveways. `,� res+st've Figure 6 rater-rM6tHe 1 barn& e �� Figure 4 1 -7 = r-r , /! Sio I0,. low l It I rasrung r.1001r • 9 min lap wog L--_ Figure 9 .,. . Maintain a 1/4'clearance Maintain a minimum 1"gap •i�; :� '� KICKOUT FLASHING � Because of the volume of water that can pour down between the bottom of James between gutter end caps and „a,o,,. ,��9s a sloped roof,one of the most critical flashing Hardie products and horizontal skiing&trim • f details occurs where a roof intersects a sidewall, flashing.Do not caulk gap. Figure 8 ,•�•.rar•,• The roof must be flashed with step flashing. Where JAM `� • the rod terminates,install a lockout to deflect water Figure 7 /f�ai r� away from the siding. srduq ` It is best to install a self-adhering membrane on the Do r� 114 adK gI wall before the subfascia and trim boards are nailed Caulk { s I in place,and then come back to install the lockout ` fasoa Figure 9,Kickout Flashing=To prevent water from dumping behind the siding and the eaA"'9 �`!' all end of the roof intersection,install a"lockout"of sufficient length and angle to direct the gutter and end cap water running down the roof away from the siding. FASTENER REQUIREMENTS " Blind Nailing is the preferred method of installation for all HardiePtank•lap siding products BLIND HALING FACE NAILING Nails-Wood Framing Nails-Wood Framing •Siding nail(0.09"shank x D.221"HD x 2"long) •(id(0.113"shank x 0.267"HD x 2"long) •1 lga.roofing nail(0.121"shank x 0.371"HO x 1.25"long) •Siding nail(0.09"shank x 0 221"HD x 2'lung) Screws-Steel Framing Screws-Steel Framing •Ribbed Water-head Or equivalent(No.8 x 1 1/4"long •Ribbed Bugle-head or equivalent(No.8-18 x 1-5/8"long x x 0.375"HD)Screws must penetrate 3 threads into metal framing 0.323"HD)Screws must penetrate 3 threads into metal framing Nails-Steel Framing Nails-Steel Framing •ET&F Panelfast"nails a equivalent(0.10"shank x 0.313"HD x 1-1/2"long) •ET&F pin or equivalent(0.10"shank x 0.25"HD x 1-1/2"long) Nails must penetrate minimum 1/4"into metal framing. Nails must penetrate minimum 1/4"into metal framing OSB minimum 7116" 0S8 minimum 7/16" •11 ga.roofing nail(0.121"shank x 0.371'HD x 1.75'long) •Siding nail(0.09"shank x 0.221"HD x 1-1/2"long)' •Ribbed Wafer-head or equivalent(No.8 x 1 5/8`long x 0.375'HD). 24"---------i' stud - —�0 C.max - V 24" Figure 10 Figure 11 �j `- 1 1i4'mm. stud O C.max � Yi — overlap water-resrsnve _ Minimum overlap barrier _. -- ° for Botts Face ' ' .J.- 0blind nail 1 and Blind Nailing \ _ - - oc ,...-"1-/ a II1(I &41/1/1111111111111 mm1 1/4" Iverlap1111-4- 101t � ; __ water-res,stne water-resrstrve ' �.Jy barrier 1 1.4"inn. banner .__1' -- overlap L. Laminate sheet to be removed immediately after installation of each course for ColorPlus°products. z The illustration(figure 9)and associated text was reprinted with permission of IHI:JOUHNAI OF LIGHT CONSTRICTION For subscnption information.visit wvwvjkl)nline.com. • When face nailing to OSB.planks must be no greater than 9 1/4"wide and fasteners must be 12"o.c.or less. • Also see General Fastening Requirement and when consderlrlg alternative fastening optics refer to James Hardie's Technical Bulletin USTB 17-Fastening Tips for BardtePtank•Lap Siding HS0920-P214 10,10 JOB COPY 1.1714. GENERAL FASTENING REQUIREMENTS •Consult applicable code compliance report for correct fasteners type and Fasteners must be corrosion resistant,galvanized,or stainless steel placement to achieve specified design wind loads. Electro-galvanized are acceptable but may exhibit premature corrosion. •NOTE Published wind loads may not be applicable to all areas where James Hardie recommends the use of quality,tot dipped galvanized Local Building Codes have specific jurisdiction Consult James Hardie nails. James Hardie is not responsible for the corrosion resistance of Technical Services if you are unsure of applicable compliance documentation. •Drive fasteners perpendicular to siding and framing fasteners. Stainless steel fasteners are recommended when installing •Fastener heads should fit snug against siring(no air space).(fig.A i James Hardie products near the ocean.large bodies of water,or in •Do not overdrive nail heads or drive nails at an angle. very humid climates. •If nail is countersunk,caulk nail hole and add a nail (fig B) PNEUMATIC FASTENING •For wood framing,under driven nails should be hit flush to the plank with a James Hardie products can be hand nailed or fastened with a pneumatic tool. hammer(For steel framing,remove and replace nail) Pneumatic fastening is highly recommended. Set air pressure so that the •Do not use aluminum fasteners,staples,or clipped head nails. fastener is driven snug with the surface of the siding A flush mount Snug Flush attachment on the pneumatic tool is recommended. This will help control the t��Coucauntersunk, (Lb, 0 depth the nail is driven If setting the nail depth proves difficult,choose a t�• ',P add 111ai1 setting that under drives the nail. (Drive under driven nails snug with a do not under DO NOT smooth faced hammer-Does not apply for installation to steel framing). Figure A Figure B drive nails STAPLE CAULKING PAINTING For best results use an Elastomeric Joint Sealant complying DO NOT use stain on James Hardie•products.James Hardie products must be with ASTM C920 Grade NS.Class 25 or higher ora Latex painted within 180 days for primal product and 90 days for unpnmed.100% Joint Sealant complying with ASTM C834 Caulking7Sealant acrylic topcoats are recommended. Do not paint when wet.For application rates must be applied in accordance with the caulking/sealant refer to paint manufacturers specifications.Back-rolling is recommended if the manufacturer's written instructions or ASTM C1193. siding is sprayed. COLORPLUS°TECHNOLOGY CAULKING,TOUCH-UP& LAMINATE •Touch up nicks,scrapes and nail heads using the CobrPlus•Technology touch-up applicator Touch-up paint should he used spanngly If large areas require touch-up,replace the damaged area with new HardiePlank•lap skiing with ColorPlus Technology. •Laminate sheet must be removed immediately after installation of each course. •Terminate non-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPlus product dealer. •Treat all other non-factory cut edges using the ColorPlus Technology edge coolers,available from your ColorPlus product dealer. PAINTING JAMES HARDIE°SIDING AND TRIM PRODUCTS WITH COLORPLUSa TECHNOLOGY When repainting ColorPlus products,James Hardie recommends the following regarding surface preparation and topcoat application •Ensure the surface is clean,dry,and free of any dust,dart,or mildew •Repriming is normally not necessary • 100%acrylic topcoats are recommended •DO NOT use stain or oil/alkyd base paints on James Hardie'products •Apply finish coat in accordance with paint manufacturers written instructions regarding coverage.application methods,and application temperature COVERAGE CHARTIESTIMATING GUIDE Number of 12'planks,does not include waste COVERAGE AREA LESS OPENINGS HARDIEPLANK'LAP SIDING WIDTH SO 5114 614 114 71(2 8 61/4 9114 91/2 12 (1 so=100 sq 1( (exposure) 4 5 6 6114 614 7 8 8114 103/4 1 25 20 17 16 15 14 13 13 9 2 50 40 33 32 30 29 25 25 19 3 75 60 50 48 4-4 43 38 38 28 4 100 80 67 64 59 57 50 50 37 5 125 100 83 80 74 71 63 63 47 6 150 120 100 96 89 86 75 75 56 7 175 140 117 112 104 100 88 88 65 8 200 160 133 128 119 114 100 100 74 9 225 180 150 144 133 129 113 113 84 10 250 200 167 160 148 143 125 125 93 11 275 220 183 176 163 157 138 138 102 12 300 240 200 192 178 171 150 150 112 13 325 260 211 208 193 186 163 163 121 14 350 280 233 224 207 200 175 175 130 15 375 300 250 240 222 214 188 188 140 16 400 320 267 256 237 229 200 200 149 17 425 340 283 272 252 243 213 213 158 18 450 360 300 288 267 257 225 225 167 19 475 380 317 304 281 271 238 238 t77 20 500 400 333 320 296 286 250 250 186 This coverage chart is meant as a guide.Actual usage is subject to variables such as building design.James Hardie does not assume responsibility for over or under ordering of product. RECOGNITION:in accordance rah ICC-ES legacy Report NER405 HadrPtank lap Wing a recognized as a suitable alternate to that spoofed or the BOCA National Bidding Code)1999,the 1997 Standard Bakig Code.the 1997 Uniform Bidding Code.the 1998 kee'rateral ore-ant Iao•Farry NON Code.the 20031neruataoal Budding Code and the 2003 Mernahond i2esdeneal Code for One-and Two Feely Owings.Hard,ePtahk lap snag 4 also recognized for appkaon in the fdaeleg Cory or Los Angeles Research Report No 24862,State of Florida Wog F Le889 Oade County Fbrda NOA No 02-0729 02. u S Dep at 111X)Wends Release 1263c,Texas Departney of ksumce Product Evaluation EC-23.City of New Yat IAEA 223-93-It and Cadorrsa OSA M-019 These docunecis should abo be mesa*ed for adddaxral srlennatioe concerning the suitability of this product to spede appfcakas HS0920-P3/4 10/10