1889 Atlantic Beach Dr ROW21-0061 Comcast CableOWNER:ADDRESS:CITY:STATE:ZIP:
AMERAULT JAMES F 1889 ATLANTIC BEACH DR ATLANTIC BEACH FL 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
SOUTHEAST UTILITIES 1 ENERGY PL PENSACOLA FL 32520
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169505 1575 ATLANTIC BEACH
COUNTRY CLUB UNIT 02
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1889 ATLANTIC BEACH DR RIGHT OF WAY COMMERCIAL
RIGHT OF WAY
COMCAST - CABLE
REPLACEMENT $0.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL
Notes:
Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is
needed, call 247-5878
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 10/11/2021
PERMIT NUMBER
ROW21-0061
ISSUED: 10/11/2021
EXPIRES: 1/9/2022
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
2 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247-
5814) to request an Erosion and Sediment Control Inspection prior to start of construction.
3 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL
Notes:
Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container
cannot be placed on City right-of-way.
5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
6 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
7 PUBLIC WORKS AS-BUILT INFORMATIONAL
Notes:
Contractor must submit As-Built plans to City within 30 days after completion of project.
2 of 2Issued Date: 10/11/2021
PERMIT NUMBER
ROW21-0061
ISSUED: 10/11/2021
EXPIRES: 1/9/2022
RIGHT OF WAY PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
½;W-\.i'J:r 1$ !r}
Q • ,j> ~ 11\
;:;' ,.!\ -;> _, ,. S-) u .....,..-2:
~J.Q;il\:J~
I I I
I I I
I I I
I I I
I I l
I I l
ROW210061
RIGHT-OF-WAY/ EASEMENT PERMIT APPLICATION
City of Atlantic Beach
800 Seminole Road, Atlantic Beach, FL 32233
PERMITTEE RE PONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES
0 ALL INFORMATION
HIGHLIGHTED IN GRAY IS
REQUIRED.
Job Address 1aa9 ATlANTic BEACH DR Permit Number __________ _
Contractor Information
Address 1 Energ Pl
Phone (850) 363-3284
City Pensacola
Emai l ggavagni@icdllc.com
State Eh__ Zip 32520
State Certification/Regi tration # ______________________________ _
Architect __________________ Phone __________ Email _________ _
Engineer Gina Gavagni Phone (850) 363-3284 Email ggavagni@icdllc .com
Wor ers Compensation lnsurer_0 ____________________ 0R ExemptOExpiration Date ____ _
• Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial
and underground and the accurate locations are shown on the sketches.
• Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or
relocation of all, or any portion of said street or easement as determined by the Public Works Director, any or all said poles,
wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said
street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the
Permittee unless reimbursem ent is authorized.
• All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the
supervision of nm Salyard {Project Superintendent}
with (Company Name} SEU Phone_(9_0_4_) _53_1_-6_9_85 _______ _
• All materials and equ ipment shall be subject to inspection by the Public Works Director.
•
•
•
•
All city property shall be restored to its original condition as far as practical, in keeping with City specificat ions and the
manner satisfactory to the City.
A sketch of plans covering details of this installation, as well as a copy of a recent survey shall be made a part of this permit .
calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be ncl ded
is application.
The permittee shall commence actual construction in good faith within 30 days . If the beginning date is more than 60
days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no
changes have occurred in the area that would affect the permitted construction.
It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,
title and interest in the land to be entered upon and used by the holder, and the holder will, at all times, assume all risk of
and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss, damage and cost of
expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges.
The Publi Works · ecto shall be notified 24 hours prior to starting work and again immediately upon completion.
--+~....,.~--__.,,,_,¥..;lt.....;=..y...~.,__ ____________________ Date-\::ci-i&-h-:r--.'-+~~==~...--\
STATE OF FLORIDA, COUNTY OF DUVAL
The foregoing instrument was acknowledged this
Signatur
H:\Applicatlons & Forms\Word Documents\201801001 Right-of-Way Easement Permit Appllcatlon.docx Revision Date: 10/1/18
I DUVAL COUNTY I
VICINITY MAP:
OKALOOS
COUNTY
1889 ATLANTIC BEACH DR
ATLANTIC BEACH, FL 32233
HARDEE
COUNTY
DESOTO
COUNTY
CHARLOTT E
COUNTY
OSCEOLA
COUNTY
OKEECHOBEE
OUNTY
GLADES
COUNTY
HENDRY
COUNTY
MONROE
COUNTY
PALM
BEACH
COUNTY
BROWARD
COUNTY
MIAMI -DADE
COUNTY
COMCAST PERMIT REQUEST FOR LOCATION:
1889 ATLANTIC BEACH DR
ATLANTIC BEACH, FL 32233
THESE PLANS WERE PREPARED UNDER THE
RESPONSIBLE CHARGE OF COMCAST
JB798449
NO EXPECTED CONFLICTS
WITH OTHER UTILITIES
LOCATION: 1889 ATLANTIC BEACH DR
ATLANTIC BEACH, FL 32233
TOTAL LENGTH OF JOB: 73' UG
DESCRIPTIO : DIRECTIONAL BORE
PLACEMENT
DRAWN BY: JDO
DATE: 09/28/2021
SCALE: NTS
SHEET
1 OF 4
NOTES:
ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A
MINIMUM OF 36".
ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE
CITY APPROVED DIRECTIONAL BORE MACHINE, AS WELL AS
COUNTY APPROVED CONDUIT.
ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM
OF 7' BEYOND THE EDGE OF PAVEMENT.
ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A
MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT.
ALL PROPOSED BORES WILL BE IN A ( 4'X4'X4') PIT AND
WILL USE (2)2" HOPE CONDUIT AT 48" DEPTH USING A 5
1 / 4" DRILL HEAD.
ALL PROPOSED AERIAL WILL BE .700" DIAMETER AND WILL
BE LASHED TO .250" STEEL STRAND CABLE USING .125"
STANDARD GALVANIZED LASHING WIRE.
ALL PROPOSED AERIAL CATV CROSSING ROADWAYS WILL
HAVE MINIMUM MID-SPAN HEIGHT OF 18' -0"
ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL
HAVE MINIMUM MID-SPAN HEIGHT OF 16' -0"
LOCATES WILL BE REQUIRED IN ALL PROPOSED
UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO
CONSTRUCTION.
NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE
PRIOR TO CONSTRUCTION.
ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE
RESTORED TO ORIGINAL OR BETTER CONDITION BY GRADING
AND RE-SODDING. SOD ALL AREAS DISTURBED BY
CONSTRUCTION WITH BERMUDA SOD. "ALL CRACKED
SIDEWALK IS TO BE REPLACED FROM JOINT TO JOINT WITHIN
7 DAYS OF WORK COMPLETION."
WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE
THE PAVER SIDEWALK WHEN POSITIONING EQUIPMENT. ANY
DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR
REPLACED BY THE CONTRACTOR.
CONSTRUCTION NOTES:
IN ORDER TO REDUCE THE DISRUPTION AND COST OF
UTILITY DAMAGES OCCURRING IN THE RIGHT-OF-WAY AND
EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO
EXISTING UTILITIES CAUSED BY THE WORK THROUGH FIELD
VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES
IN CASE OF OPEN EXCAVATION. VERIFICATION MAY BE
PERFORMED DURING THE PERMITTEES WORK. IN THE CASE
OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE
PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT.
THE PERMITTEE SHALL VERIFY THE LOCATION OF THE
EXISTING UTILITIES AS NEEDED TO AVOID CONTACT WITH
DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH
METHODS MAY INCLUDE BUT SHALL NOT BE LIMITED
TO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION
RADAR (GPR). THE EXCAVATOR SHALL BE HELD LIABLE FOR
DAMAGES CAUSED TO CITY'S/COUNTIES/STATE INFRASTRURE
AND THE EXISTING FACILITIES OF THE OTHER UTILITY
COMPANIES
NO REAMER USED
THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE
WITH THE FL DEPARTMENT OF TRANSPORTATION
602 INDEX AND APPLY TO:
1889 ATLANTIC BEACH DR, ATLANTIC BEACH, FL 32233
COMCAST PERMIT REQUEST FOR
LOCATION:
1889 ATLANTIC BEACH DR
ATLANTIC BEACH, FL 32233
I NO BACKREAMER USED I
I NO EXPECTED CONFLICTS I
WITH OTHER UTILITIES
LOCATION: 1889 ATLANTIC BEACH DR
ATLANTIC BEACH, FL 32233
TOTAL LENGTH OF JOB: 73' UG
DESCRIPTION: CATV DIRECTIONAL BORE
PLACEMENT
DRAWN BY: JDO
DATE: 09/28/2021
SCALE: NTS
SHEET
2 OF 4
ATLANTIC BEACH DR
;:: TYP ALLOCATION
.........
o'
13'
t,
20'
t,
~ ~
Uo... 0... u
5' S -0 0 NW w N
C/L
I 1 i~
~
<( u
V)
1895
1894
;::
BEGIN UG ~1~~
CATV PED
.,, ,,,,---=--.: ----....
.........
13' /
I
-36" MIN I
I
-48" MIN I
I
\
0 ...J WWW I-: ...J I-<(
~w u \
\
PROPOSED BORE PLACEMENT
FOR 73' ALONG
ATLANTIC BEACH DR
AT MIN DEPTH OF 36"
USING 2" 13.5 SDR ROLL PIPE
WITH COAXIAL CABLE INSIDE
/
/
/
I
/
I
I
\
I
I
I
I
+73
END UG HERE
CATV PED
I
\
I
\
I
\
~
NO BACKREAMER USED
NO EXPECTED CONFLICTS
WITH 0TH ER UTILITIES
LOCATION: 1889 ATLANTIC BEACH DR
ATLANTIC BEACH, FL 32233
TOTAL LENGTH OF JOB: 73' UG
DESCRIPTIO : BORE
PLACEMENT
DRAWN BY: JOO
DATE: 09/28/2021
SCALE: NTS
SHEET
3 OF 4
EN D
ROA D WOR K
tjJ
<=
A
<=
tjJ
ROAD
WORK
AHEAD
---------------------------------------------<f------------------------------
==:> I ==:>
[p [p [p ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ [p
I ■
A B
* I
ROAD I({;, WORK
AHEAD SPEEDING FINES
DOUBLED
WHEN WORKERS
PRESENT
Device Spacing-Taper Device Spacing-Tan gent
See Table I See Table I
Table I
500'
EN D
ROAD WORK
Device Spacinq
Max. Distance Between Devices (ft.)
Speed Cones or
Type I or Type II
Barricades or Vertical
DISTANCE BETWEEN SIGNS (mph) Tubular Markers Panels or Drums
Speed
40 mp h or less
45 mph
50 mph or greater
*Midway between signs .
SYMBOLS
~ Work Area
■ Channelizing Device (See Index 102-600)
[p Work Zone Sign
==:> Lane Identification + Direction of Traffic
<: DESCRIPTION:
0
Spacing (ft.) T aper Ta ngent Tap er
A B 25 25 50 25
200
350
500
200 30 to 45 25 50 30
350 50 to 70
500 25 50 50
GENERAL NOTES
1. When four or more work vehicles enter the through traffic lanes in a one hour
period or less (excluding establishing and terminating the work area}, the advanced
FLAGGER sign shall be substituted for the WORKERS sign . For location of flaggers
and FLAGGER signs. see Index 102-603.
2. SHOULDER WORK sign may be used as an alternate to the WO RKER symbol sign only
on the side where the shoulder work is being performed.
3. When a side road intersects the highway within the TT C zone, additional TT C
devices shall be placed in accordance with o t her applicable TCZ Indexes.
4. For general TCZ requirements and additional information, ref er to Ind ex 102-600.
FY 2020-21
T angent
50
50
100
DURATION NOTES
1. Signs and channelizing devices may be omitted if all of the
following conditions are met :
a. Work operations are 60 minutes or less.
b. Vehicles in the work area have high-intensity, rotating,
flashing, oscillating, or strobe lights operating.
Table II
Taper Length -Shoulder
½L (ft)
Speed
(mph) 8 ' 10'
Notes
12'
Shldr. Shldr. Shldr.
25 28 35 42
30 40 50 60 L= ws 2
35 55 68 82 60
40 72 90 107
45 120 150 180
50 133 167 2 00
55 147 183 220
60 160 200 240 L=WS
65 173 217 260
70 187 233 280
8' minimum shoulder width
½L = Length of shoulder taper in feet
W = Width of total shoulder in feet
(combined paved and unpav ed width)
5 = Posted speed limit (mph)
CONDITIONS
WHERE ANY VEHICLE , EQUIPMENT,
WORKERS OR THEIR ACTIVITIES
ENCROACH THE AREA CLOSER
THAN 15' BUT NOT CLOSER TH AN
2' TO THE EDGE OF TRAVEL WAY.
INDEX LAST
REVISION
11/01/17
vi ;;; ST AN OARD PLANS TWO -LANE , TWO -WAY, WORK ON SHOULDER
102-602 LU
Ct'.
SHEET
4 OF 4