Loading...
1889 Atlantic Beach Dr ROW21-0061 Comcast CableOWNER:ADDRESS:CITY:STATE:ZIP: AMERAULT JAMES F 1889 ATLANTIC BEACH DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: SOUTHEAST UTILITIES 1 ENERGY PL PENSACOLA FL 32520 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 1575 ATLANTIC BEACH COUNTRY CLUB UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1889 ATLANTIC BEACH DR RIGHT OF WAY COMMERCIAL RIGHT OF WAY COMCAST - CABLE REPLACEMENT $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247-5878 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/11/2021 PERMIT NUMBER ROW21-0061 ISSUED: 10/11/2021 EXPIRES: 1/9/2022 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: 2 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. 3 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 6 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 7 PUBLIC WORKS AS-BUILT INFORMATIONAL Notes: Contractor must submit As-Built plans to City within 30 days after completion of project. 2 of 2Issued Date: 10/11/2021 PERMIT NUMBER ROW21-0061 ISSUED: 10/11/2021 EXPIRES: 1/9/2022 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ½;W-\.i'J:r 1$ !r} Q • ,j> ~ 11\ ;:;' ,.!\ -;> _, ,. S-) u .....,..-2: ~J.Q;il\:J~ I I I I I I I I I I I I I I l I I l ROW210061 RIGHT-OF-WAY/ EASEMENT PERMIT APPLICATION City of Atlantic Beach 800 Seminole Road, Atlantic Beach, FL 32233 PERMITTEE RE PONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES 0 ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Job Address 1aa9 ATlANTic BEACH DR Permit Number __________ _ Contractor Information Address 1 Energ Pl Phone (850) 363-3284 City Pensacola Emai l ggavagni@icdllc.com State Eh__ Zip 32520 State Certification/Regi tration # ______________________________ _ Architect __________________ Phone __________ Email _________ _ Engineer Gina Gavagni Phone (850) 363-3284 Email ggavagni@icdllc .com Wor ers Compensation lnsurer_0 ____________________ 0R ExemptOExpiration Date ____ _ • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Public Works Director, any or all said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursem ent is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of nm Salyard {Project Superintendent} with (Company Name} SEU Phone_(9_0_4_) _53_1_-6_9_85 _______ _ • All materials and equ ipment shall be subject to inspection by the Public Works Director. • • • • All city property shall be restored to its original condition as far as practical, in keeping with City specificat ions and the manner satisfactory to the City. A sketch of plans covering details of this installation, as well as a copy of a recent survey shall be made a part of this permit . calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be ncl ded is application. The permittee shall commence actual construction in good faith within 30 days . If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder, and the holder will, at all times, assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss, damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. The Publi Works · ecto shall be notified 24 hours prior to starting work and again immediately upon completion. --+~....,.~--__.,,,_,¥..;lt.....;=..y...~.,__ ____________________ Date-\::ci-i&-h-:r--.'-+~~==~...--\ STATE OF FLORIDA, COUNTY OF DUVAL The foregoing instrument was acknowledged this Signatur H:\Applicatlons & Forms\Word Documents\201801001 Right-of-Way Easement Permit Appllcatlon.docx Revision Date: 10/1/18 I DUVAL COUNTY I VICINITY MAP: OKALOOS COUNTY 1889 ATLANTIC BEACH DR ATLANTIC BEACH, FL 32233 HARDEE COUNTY DESOTO COUNTY CHARLOTT E COUNTY OSCEOLA COUNTY OKEECHOBEE OUNTY GLADES COUNTY HENDRY COUNTY MONROE COUNTY PALM BEACH COUNTY BROWARD COUNTY MIAMI -DADE COUNTY COMCAST PERMIT REQUEST FOR LOCATION: 1889 ATLANTIC BEACH DR ATLANTIC BEACH, FL 32233 THESE PLANS WERE PREPARED UNDER THE RESPONSIBLE CHARGE OF COMCAST JB798449 NO EXPECTED CONFLICTS WITH OTHER UTILITIES LOCATION: 1889 ATLANTIC BEACH DR ATLANTIC BEACH, FL 32233 TOTAL LENGTH OF JOB: 73' UG DESCRIPTIO : DIRECTIONAL BORE PLACEMENT DRAWN BY: JDO DATE: 09/28/2021 SCALE: NTS SHEET 1 OF 4 NOTES: ALL PROPOSED UNDERGROUND CATV WILL BE BURIED A MINIMUM OF 36". ALL PROPOSED UNDERGROUND CATV ROAD BORES WILL USE CITY APPROVED DIRECTIONAL BORE MACHINE, AS WELL AS COUNTY APPROVED CONDUIT. ALL PROPOSED CATV ROAD BORES WILL EXTEND A MINIMUM OF 7' BEYOND THE EDGE OF PAVEMENT. ALL PROPOSED CATV DRIVEWAY BORES WILL EXTEND A MINIMUM OF 6' BEYOND THE EDGE OF PAVEMENT. ALL PROPOSED BORES WILL BE IN A ( 4'X4'X4') PIT AND WILL USE (2)2" HOPE CONDUIT AT 48" DEPTH USING A 5 1 / 4" DRILL HEAD. ALL PROPOSED AERIAL WILL BE .700" DIAMETER AND WILL BE LASHED TO .250" STEEL STRAND CABLE USING .125" STANDARD GALVANIZED LASHING WIRE. ALL PROPOSED AERIAL CATV CROSSING ROADWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 18' -0" ALL PROPOSED AERIAL CATV CROSSING DRIVEWAYS WILL HAVE MINIMUM MID-SPAN HEIGHT OF 16' -0" LOCATES WILL BE REQUIRED IN ALL PROPOSED UNDERGROUND AREAS AT LEAST 48 HRS PRIOR TO CONSTRUCTION. NOTIFICATIONS TO ALL UTILITIES INVOLVED WILL BE MADE PRIOR TO CONSTRUCTION. ALL DISTRIBUTED AREA WITHIN THE RIGHT OF WAY WILL BE RESTORED TO ORIGINAL OR BETTER CONDITION BY GRADING AND RE-SODDING. SOD ALL AREAS DISTURBED BY CONSTRUCTION WITH BERMUDA SOD. "ALL CRACKED SIDEWALK IS TO BE REPLACED FROM JOINT TO JOINT WITHIN 7 DAYS OF WORK COMPLETION." WORK OPERATIONS ARE TO BE MINDFUL NOT TO DAMAGE THE PAVER SIDEWALK WHEN POSITIONING EQUIPMENT. ANY DAMAGE INCLUDING TRACK MARKS WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR. CONSTRUCTION NOTES: IN ORDER TO REDUCE THE DISRUPTION AND COST OF UTILITY DAMAGES OCCURRING IN THE RIGHT-OF-WAY AND EASEMENTS. THE PERMITTEE SHALL PREVENT DAMAGES TO EXISTING UTILITIES CAUSED BY THE WORK THROUGH FIELD VERIFICATION OF THE LOCATION OF THE EXISTING UTILITIES IN CASE OF OPEN EXCAVATION. VERIFICATION MAY BE PERFORMED DURING THE PERMITTEES WORK. IN THE CASE OF DIRECTIONAL DRILLING, VERIFICATION SHALL TAKE PLACE PRIOR TO MOBILIZATION OF THE DRILLING EQUIPMENT. THE PERMITTEE SHALL VERIFY THE LOCATION OF THE EXISTING UTILITIES AS NEEDED TO AVOID CONTACT WITH DETECTION EQUIPMENT OR OTHER ACCEPTABLE MEANS, SUCH METHODS MAY INCLUDE BUT SHALL NOT BE LIMITED TO-"SOFT DIG"-EQUIPMENT AND GROUND PENETRATION RADAR (GPR). THE EXCAVATOR SHALL BE HELD LIABLE FOR DAMAGES CAUSED TO CITY'S/COUNTIES/STATE INFRASTRURE AND THE EXISTING FACILITIES OF THE OTHER UTILITY COMPANIES NO REAMER USED THE FOLLOWING STANDARD PLANS ARE IN ACCORDANCE WITH THE FL DEPARTMENT OF TRANSPORTATION 602 INDEX AND APPLY TO: 1889 ATLANTIC BEACH DR, ATLANTIC BEACH, FL 32233 COMCAST PERMIT REQUEST FOR LOCATION: 1889 ATLANTIC BEACH DR ATLANTIC BEACH, FL 32233 I NO BACKREAMER USED I I NO EXPECTED CONFLICTS I WITH OTHER UTILITIES LOCATION: 1889 ATLANTIC BEACH DR ATLANTIC BEACH, FL 32233 TOTAL LENGTH OF JOB: 73' UG DESCRIPTION: CATV DIRECTIONAL BORE PLACEMENT DRAWN BY: JDO DATE: 09/28/2021 SCALE: NTS SHEET 2 OF 4 ATLANTIC BEACH DR ;:: TYP ALLOCATION ......... o' 13' t, 20' t, ~ ~ Uo... 0... u 5' S -0 0 NW w N C/L I 1 i~ ~ <( u V) 1895 1894 ;:: BEGIN UG ~1~~ CATV PED .,, ,,,,---=--.: ----.... ......... 13' / I -36" MIN I I -48" MIN I I \ 0 ...J WWW I-: ...J I-<( ~w u \ \ PROPOSED BORE PLACEMENT FOR 73' ALONG ATLANTIC BEACH DR AT MIN DEPTH OF 36" USING 2" 13.5 SDR ROLL PIPE WITH COAXIAL CABLE INSIDE / / / I / I I \ I I I I +73 END UG HERE CATV PED I \ I \ I \ ~ NO BACKREAMER USED NO EXPECTED CONFLICTS WITH 0TH ER UTILITIES LOCATION: 1889 ATLANTIC BEACH DR ATLANTIC BEACH, FL 32233 TOTAL LENGTH OF JOB: 73' UG DESCRIPTIO : BORE PLACEMENT DRAWN BY: JOO DATE: 09/28/2021 SCALE: NTS SHEET 3 OF 4 EN D ROA D WOR K tjJ <= A <= tjJ ROAD WORK AHEAD ---------------------------------------------<f------------------------------ ==:> I ==:> [p [p [p ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ [p I ■ A B * I ROAD I({;, WORK AHEAD SPEEDING FINES DOUBLED WHEN WORKERS PRESENT Device Spacing-Taper Device Spacing-Tan gent See Table I See Table I Table I 500' EN D ROAD WORK Device Spacinq Max. Distance Between Devices (ft.) Speed Cones or Type I or Type II Barricades or Vertical DISTANCE BETWEEN SIGNS (mph) Tubular Markers Panels or Drums Speed 40 mp h or less 45 mph 50 mph or greater *Midway between signs . SYMBOLS ~ Work Area ■ Channelizing Device (See Index 102-600) [p Work Zone Sign ==:> Lane Identification + Direction of Traffic <: DESCRIPTION: 0 Spacing (ft.) T aper Ta ngent Tap er A B 25 25 50 25 200 350 500 200 30 to 45 25 50 30 350 50 to 70 500 25 50 50 GENERAL NOTES 1. When four or more work vehicles enter the through traffic lanes in a one hour period or less (excluding establishing and terminating the work area}, the advanced FLAGGER sign shall be substituted for the WORKERS sign . For location of flaggers and FLAGGER signs. see Index 102-603. 2. SHOULDER WORK sign may be used as an alternate to the WO RKER symbol sign only on the side where the shoulder work is being performed. 3. When a side road intersects the highway within the TT C zone, additional TT C devices shall be placed in accordance with o t her applicable TCZ Indexes. 4. For general TCZ requirements and additional information, ref er to Ind ex 102-600. FY 2020-21 T angent 50 50 100 DURATION NOTES 1. Signs and channelizing devices may be omitted if all of the following conditions are met : a. Work operations are 60 minutes or less. b. Vehicles in the work area have high-intensity, rotating, flashing, oscillating, or strobe lights operating. Table II Taper Length -Shoulder ½L (ft) Speed (mph) 8 ' 10' Notes 12' Shldr. Shldr. Shldr. 25 28 35 42 30 40 50 60 L= ws 2 35 55 68 82 60 40 72 90 107 45 120 150 180 50 133 167 2 00 55 147 183 220 60 160 200 240 L=WS 65 173 217 260 70 187 233 280 8' minimum shoulder width ½L = Length of shoulder taper in feet W = Width of total shoulder in feet (combined paved and unpav ed width) 5 = Posted speed limit (mph) CONDITIONS WHERE ANY VEHICLE , EQUIPMENT, WORKERS OR THEIR ACTIVITIES ENCROACH THE AREA CLOSER THAN 15' BUT NOT CLOSER TH AN 2' TO THE EDGE OF TRAVEL WAY. INDEX LAST REVISION 11/01/17 vi ;;; ST AN OARD PLANS TWO -LANE , TWO -WAY, WORK ON SHOULDER 102-602 LU Ct'. SHEET 4 OF 4