Loading...
1725 Beach Avenue SITE PLAN ElevationE1 7'-0" AFFE1E1 E1E1 8'-0" AFFin ceiling lighting E1 A3.1 1. 2. 3. 4. Do not scale Drawings. Use only dimensions shown on drawings. If dimensions are in question, the electrician shall be responsible for obtaining clarification before continuing with construction. Builder shall verify all dimensions & conditions at jobsite. See A0.1 for specifications & Notes See E2.4 for exterior lighting schedule. Sea turtle protection requirements F.A.C 62B-34.070(4) : (a.) All windows and glass doors on the seaward and shore parallel sides of the dwelling shall be tinted to a Transmittance Value of 45% or less through the use of tinted glass, window film or screens. (b.) All lighting will comply with types of lighting authorized by the general Permit." Elevation Notes West Elevation 34'-4" from average calculated grade to peak of roof19.9' average calculated grade as per Boatwright Surveyors2'-7"3'-6"3'-1"0' NAVD 100 yr Floor 15.1' NAVD 15.100' flood elevation4'-0"Sheet Copyright ©2019 Starr Sanford Design Associates, Inc. All rights reserved. The design concepts, drawings, written material, and specifications of this document are the property of Starr Sanford Design Associates, Inc. No part of these documents shall be copied, disclosed to others, or reproduced in part or whole in any form without the written consent of Starr Sanford Design Associates, Inc. Do not scale drawings. Use given dimensions only. If not shown, verify the correct dimensions with Starr Sanford Design Associates, Inc. Contractor shall check and verify all dimensions and conditions of the job site. residential design Atlantic Caribbean Pacific info@starrsanford.com 904-707-9761 Project #: Date: Revised: drawn: MLS DEP approval set 18011 5/13/19F r i s c h R e s i d e n c e 1 7 2 5 B e a c h A v e . A t l a n t i c B e a c h , F l w w w . s t a r r s a n f o r d . c o m ( 9 0 4 ) 7 0 7 - 9 7 6 1Scale1/4" 1'-0" E1 9'-0" AFFE2 1'-0" above2nd floor FFsee plan for exterior lighting in this area A3.2 North Elevation 1. 2. 3. 4. Do not scale Drawings. Use only dimensions shown on drawings. If dimensions are in question, the electrician shall be responsible for obtaining clarification before continuing with construction. Builder shall verify all dimensions & conditions at jobsite. See A0.1 for specifications & Notes See E2.4 for exterior lighting schedule. Sea turtle protection requirements F.A.C 62B-34.070(4) : (a.) All windows and glass doors on the seaward and shore parallel sides of the dwelling shall be tinted to a Transmittance Value of 45% or less through the use of tinted glass, window film or screens. (b.) All lighting will comply with types of lighting authorized by the general Permit." Elevation Notes Sheet Copyright ©2019 Starr Sanford Design Associates, Inc. All rights reserved. The design concepts, drawings, written material, and specifications of this document are the property of Starr Sanford Design Associates, Inc. No part of these documents shall be copied, disclosed to others, or reproduced in part or whole in any form without the written consent of Starr Sanford Design Associates, Inc. Do not scale drawings. Use given dimensions only. If not shown, verify the correct dimensions with Starr Sanford Design Associates, Inc. Contractor shall check and verify all dimensions and conditions of the job site. residential design Atlantic Caribbean Pacific info@starrsanford.com 904-707-9761 Project #: Date: Revised: drawn: MLS DEP approval set 18011 5/13/19F r i s c h R e s i d e n c e 1 7 2 5 B e a c h A v e . A t l a n t i c B e a c h , F l w w w . s t a r r s a n f o r d . c o m ( 9 0 4 ) 7 0 7 - 9 7 6 1Scale1/4" 1'-0" E2 in stepE2in stepE2in step E2 1'-0" above2nd floor FFE2 1'-0" above2nd floor FFE1 11'-0" AFFE1 11'-0" AFFE1 11'-0" AFFlocated on East wall of house above doors A3.3 East Elevation 1. 2. 3. 4. Do not scale Drawings. Use only dimensions shown on drawings. If dimensions are in question, the electrician shall be responsible for obtaining clarification before continuing with construction. Builder shall verify all dimensions & conditions at jobsite. See A0.1 for specifications & Notes See E2.4 for exterior lighting schedule. Sea turtle protection requirements F.A.C 62B-34.070(4) : (a.) All windows and glass doors on the seaward and shore parallel sides of the dwelling shall be tinted to a Transmittance Value of 45% or less through the use of tinted glass, window film or screens. (b.) All lighting will comply with types of lighting authorized by the general Permit." Elevation Notes Sheet Copyright ©2019 Starr Sanford Design Associates, Inc. All rights reserved. The design concepts, drawings, written material, and specifications of this document are the property of Starr Sanford Design Associates, Inc. No part of these documents shall be copied, disclosed to others, or reproduced in part or whole in any form without the written consent of Starr Sanford Design Associates, Inc. Do not scale drawings. Use given dimensions only. If not shown, verify the correct dimensions with Starr Sanford Design Associates, Inc. Contractor shall check and verify all dimensions and conditions of the job site. residential design Atlantic Caribbean Pacific info@starrsanford.com 904-707-9761 Project #: Date: Revised: drawn: MLS DEP approval set 18011 5/13/19F r i s c h R e s i d e n c e 1 7 2 5 B e a c h A v e . A t l a n t i c B e a c h , F l w w w . s t a r r s a n f o r d . c o m ( 9 0 4 ) 7 0 7 - 9 7 6 1Scale1/4" 1'-0" E2 1'-0" above2nd floor FFsee plan for exterior lighting in this area A3.4 South Elevation 1. 2. 3. 4. Do not scale Drawings. Use only dimensions shown on drawings. If dimensions are in question, the electrician shall be responsible for obtaining clarification before continuing with construction. Builder shall verify all dimensions & conditions at jobsite. See A0.1 for specifications & Notes See E2.4 for exterior lighting schedule. Sea turtle protection requirements F.A.C 62B-34.070(4) : (a.) All windows and glass doors on the seaward and shore parallel sides of the dwelling shall be tinted to a Transmittance Value of 45% or less through the use of tinted glass, window film or screens. (b.) All lighting will comply with types of lighting authorized by the general Permit." Elevation Notes Sheet Copyright ©2019 Starr Sanford Design Associates, Inc. All rights reserved. The design concepts, drawings, written material, and specifications of this document are the property of Starr Sanford Design Associates, Inc. No part of these documents shall be copied, disclosed to others, or reproduced in part or whole in any form without the written consent of Starr Sanford Design Associates, Inc. Do not scale drawings. Use given dimensions only. If not shown, verify the correct dimensions with Starr Sanford Design Associates, Inc. Contractor shall check and verify all dimensions and conditions of the job site. residential design Atlantic Caribbean Pacific info@starrsanford.com 904-707-9761 Project #: Date: Revised: drawn: MLS DEP approval set 18011 5/13/19F r i s c h R e s i d e n c e 1 7 2 5 B e a c h A v e . A t l a n t i c B e a c h , F l w w w . s t a r r s a n f o r d . c o m ( 9 0 4 ) 7 0 7 - 9 7 6 1Scale1/4" 1'-0" 20 Risers @ 7.0875" = 11' 9 3/4" 19 Treads @ 1' 2" = 22' 2" stairs Office/Laundry Powder 2 Wine Kitchen Sun Room elevator elevator 18" floor truss scissor truss by others property line2x6 gable wall2x6 gable wall20" floor truss 16" floor truss20" floor truss ceiling break line beyond 8" CMU8" CMU8" CMU8" CMU8" CMUtruss by others 8" CMU8" CMU8" CMU8" CMU2x4 wallslope 2" overall 12.938' garage entry floor15.1' flood elevation23.000' main house floor8'-0"9'-2"1'-6 34"9'-6 34"11' Garage Floor height varies in gable6"20.374' NTS 0' NAVD 11' grade @ property line12.438' garage floor11'-10"59'-8"10'-1"1'-8 34"8'-11 34"height varies in gable110'-10" 0' NAVD23' garage 2nd floorHouse 1st Floor 23.000' main house floorGarage Floor House 1st Floor 19.9' average calculated grade as per Boatwright Surveyors24'-0"7'-4" A3.5 House 2nd Floor 11'-9 34"Do not scale Drawings. Use only dimensions shown on drawings. If dimensions are in question, the builder shall be responsible for obtaining clarification before continuing with construction. Builder shall verify all dimensions & conditions at jobsite. All structural information shown is for reference purposes only. Builder shall have a local licensed structural engineer review actual site conditions & design all structural elements such as framing, footings, foundation walls & slabs. Their design must take into account locally-required live loads, wood species, and types of joists and rafters (dimensional lumber, LVL, metal- or plywood-web truss-joists, etc.,) any of which may vary with your locality, contractor, and building material supplier. Building sections are abstracted outlines of actual building components. See wall sections & other details for actual configurations. Finished grade lines shown are approximate. Verify that finished grade slopes away from building for at least 48" outside building perimeter. Builder shall establish finish floor elevation in consultation with Homeowner, or Architect. Builder shall take into account design intent, including number of steps, water table masonry, etc. Builder shall also assure that there is adequate clearance between finish grade & any wood construction. See details for exterior materials not shown here. Wall height dimensions are to top & bottom of wall. Actual stud height will be less, depending on number of top & bottom plates (see wall sections). Floor system dimensions are to top of plywood floor decking and bottom of joist, which typically coincides with top of wall plate for walls below or bottom of wall plate for walls above. Masonry dimensions are to top of brick or CMU. Because of drawing limitations, section cut lines on floor plans may be shown cutting through doors, windows, or other openings. But some building sections may not show openings for clarity. Because of the scale of building sections, items beyond the section plane such as doors, windows, cabinets, etc., are typically not shown unless they are required to communicate the intent of the drawing, such as columns beyond that support a porch beam. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Building Section Notes 12" CMU wall 4" CMU wall 8" CMU wall masonry veneer concrete Building Section Material Key Drawing #A A3.5 Longitudinal Building Section 100 yr Floor 15.1' NAVD 100 yr Floor 15.1' NAVD 8'-2" bottom of beam8'-2" bottom of beam7'-8" beam9'-0"12.271' garage floor19.9' Average Calculated Grade see engineering forelevator pit heightSheet Copyright ©2019 Starr Sanford Design Associates, Inc. All rights reserved. The design concepts, drawings, written material, and specifications of this document are the property of Starr Sanford Design Associates, Inc. No part of these documents shall be copied, disclosed to others, or reproduced in part or whole in any form without the written consent of Starr Sanford Design Associates, Inc. Do not scale drawings. Use given dimensions only. If not shown, verify the correct dimensions with Starr Sanford Design Associates, Inc. Contractor shall check and verify all dimensions and conditions of the job site. residential design Atlantic Caribbean Pacific info@starrsanford.com 904-707-9761 Project #: Date: Revised: drawn: MLS DEP approval set 18011 5/13/19F r i s c h R e s i d e n c e 1 7 2 5 B e a c h A v e . A t l a n t i c B e a c h , F l w w w . s t a r r s a n f o r d . c o m ( 9 0 4 ) 7 0 7 - 9 7 6 1Scale1/4" 1'-0" 0 2'4'6'8'10'12'14'16' 8" CMU8" CMU20" floor truss 20" floor truss foundation & piles as per engineeringfoundation & piles as per engineering18" floor truss framing or roof truss by others framing or roof truss by others scissor truss by others 8" CMU8" CMU8" CMU8" CMU8" CMU8" CMUA3.68'-2" bottom of beam8'-2" bottom of beam10 12 9'-0"1'-6 34"10'-1"1'-8 34"25'-0" 20'-0"8'-11 34"3" heel6'-10 34"7 12 12 12 11'-1"1'-8 34"24'-0"7'-11 34"10 12 5 12"5 12"5 12 align 6"10'-0"10"0' NAVD 12'-5 14"10'-6 34"23'-0"23' garage 2nd floor8'-0"8'-0" Garage Floor House 1st Floor 34'-4" from average calculated grade to peak of roof19.9' average calculated grade as per Boatwright Surveyors10'-1"1'-8 34"23.000' main house floor0' NAVD House 1st Floor House 2nd Floor 11'-9 34"100 yr Floor 15.1' NAVD 15.100' flood elevationDrawing #A A3.6 Traverse Building SectionStair Hall SectionDrawing #B A3.6 Drawing #B A3.6 Garage Building Section 10'-0"10"9'-2" 100 yr Floor 15.1' NAVD 22'-6"23'-0"22'-5"Sheet Copyright ©2019 Starr Sanford Design Associates, Inc. All rights reserved. The design concepts, drawings, written material, and specifications of this document are the property of Starr Sanford Design Associates, Inc. No part of these documents shall be copied, disclosed to others, or reproduced in part or whole in any form without the written consent of Starr Sanford Design Associates, Inc. Do not scale drawings. Use given dimensions only. If not shown, verify the correct dimensions with Starr Sanford Design Associates, Inc. Contractor shall check and verify all dimensions and conditions of the job site. residential design Atlantic Caribbean Pacific info@starrsanford.com 904-707-9761 Project #: Date: Revised: drawn: MLS DEP approval set 18011 5/13/19F r i s c h R e s i d e n c e 1 7 2 5 B e a c h A v e . A t l a n t i c B e a c h , F l w w w . s t a r r s a n f o r d . c o m ( 9 0 4 ) 7 0 7 - 9 7 6 1Scale1/4" 1'-0" 0 2'4'6'8'10'12'14'16' Scale1/4" 1'-0" Scale1/4" 1'-0" 8" CMU20" floor truss foundation & piles as per engineering scissor truss by others 8" CMU10'-1"1'-8 34"20'-0"3'-7 34"12 12 5 12"23' main house floor0' NAVD 5'-1"9'-10"5'-1"7'-0"A3.7 House 1st Floor House 2nd Floor 11'-9 34"19.9' average calculated grade as per Boatwright Surveyors15.100' flood elevation100 yr Floor 15.1' NAVD Drawing #A A3.7 Master Suite Building Section Sheet Copyright ©2019 Starr Sanford Design Associates, Inc. All rights reserved. The design concepts, drawings, written material, and specifications of this document are the property of Starr Sanford Design Associates, Inc. No part of these documents shall be copied, disclosed to others, or reproduced in part or whole in any form without the written consent of Starr Sanford Design Associates, Inc. Do not scale drawings. Use given dimensions only. If not shown, verify the correct dimensions with Starr Sanford Design Associates, Inc. Contractor shall check and verify all dimensions and conditions of the job site. residential design Atlantic Caribbean Pacific info@starrsanford.com 904-707-9761 Project #: Date: Revised: drawn: MLS DEP approval set 18011 5/13/19F r i s c h R e s i d e n c e 1 7 2 5 B e a c h A v e . A t l a n t i c B e a c h , F l w w w . s t a r r s a n f o r d . c o m ( 9 0 4 ) 7 0 7 - 9 7 6 1Scale1/4" 1'-0" 0 2'4'6'8'10'12'14'16'