759 Sailfish Dr ROOF21-0075 Mod Bit Roof over CarportOWNER:ADDRESS:CITY:STATE:ZIP: BARTLEY LAWILDA 4424 ELLIPSE DR JACKSONVILLE FL 32246 COMPANY:ADDRESS:CITY:STATE:ZIP: Roofcrafters Roofing, LLC 12724 GranBay Parkway #410 Jacksonville FL 32258 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171236 0000 ROYAL PALMS UNIT 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 759 SAILFISH DR ROOF NON SHINGLE MODIFIED BITUMEN ROOF OVER CARPORT $5355.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING PERMIT 455-0000-322-1000 0 $80.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.55 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $174.55 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/19/2021 PERMIT NUMBER ROOF21-0075 ISSUED: 10/19/2021 EXPIRES: 4/17/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 2 of 2Issued Date: 10/19/2021 PERMIT NUMBER ROOF21-0075 ISSUED: 10/19/2021 EXPIRES: 4/17/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $174.55 ROOF21-0075 Address: 759 SAILFISH DR APN: 171236 0000 $174.55 BLDG SUBSEQUENT PLAN REVIEW FEES $50.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING $80.00 BUILDING PERMIT 455-0000-322-1000 0 $80.00 BUILDING PLAN REVIEW $40.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE SURCHARGES $4.55 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.55 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R17740 $174.55 Printed: Tuesday, October 19, 2021 2:56 PM Date Paid: Tuesday, October 19, 2021 Paid By: Roofcrafters Roofing, LLC Pay Method: CREDIT CARD 533939801 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R17740 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION ROOF21-0075 ROOF21-0075 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 1 of 101 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6 1B Wood New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-10 1C Wood New, Reroof (Tear-Off), Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-13 1D Wood New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 14 1E Wood New, Reroof (Tear-Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 14-15 1F Wood New, Reroof (Tear-Off), Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16 1G Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-17 1H Wood New, Reroof (Tear-Off), Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 18 1I Wood New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18 2A Steel or Structural concrete New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-28 2B Steel or Structural concrete New, Reroof (Tear-Off), Recover B-2 Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 29-32 2C Steel or Structural concrete New, Reroof (Tear-Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 33-40 2D Steel or Structural concrete New, Reroof (Tear-Off), Recover C-1A Thermal Barrier with Vapor Barrier, Mech. Attached Insulation, Bonded Roof Cover 41 2E Steel or Structural concrete New, Reroof (Tear-Off), Recover C-3 Bonded and Mech. Attached Insulation, Bonded Roof Cover 41 2F Steel or Structural concrete New, Reroof (Tear-Off), Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 42-45 3A Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 46-48 3B Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 48-58 3C Structural concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 59 4A Lightweight concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 60-62 4B Lightweight concrete New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 63 4C Lightweight concrete New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 64-67 4D Lightweight concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 67 5A Cementitious wood fiber New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 68 5B Cementitious wood fiber New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 68-69 5C Cementitious wood fiber New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 70 6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 71 6B Gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 71-72 6C Gypsum Reroof (Tear-Off) C-1 Mech. Attached Insulation, Bonded Roof Cover 72 6D Gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 72-73 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 74-83 7B Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 84-101 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S, Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate, Drill-Tec #12 DP Fastener or Drill-Tec #14 HD Fastener with Drill-Tec 3” Flat Steel Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3” Recessed Steel Plate, Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 2 of 101 ➢ Steel Deck: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only); Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate; Drill-Tec Extra Heavy Duty ASAP Roofing Fastener - Insulation, Drill-Tec #12 DP Fastener, Drill-Tec #14 HD Fastener or Drill-Tec #15 EHD Fastener with Drill-Tec 3” Flat Steel Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3” Recessed Steel Plate, Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate, Drill-Tec #14 HD Fastener with Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” ASAP Flat (#14 only). Minimum 1- inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for, or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. ➢ Hot asphalt: Full Coverage at 25-30 lbs/square. If applying to concrete deck; deck shall be primed with ASTM D41 primer. ➢ GAF 2-Part Roofing Adhesive (G-2-Part): Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c. ➢ GAF LRF Adhesive M (LRF-M): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ GAF LRF Adhesive XF (LRF-XF): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ H.B. Fuller Millennium One-Step Foamable Adhesive (M-OSFA): Continuous 1-inch wide ribbons, 12-inch o.c. ➢ OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. using OMG PaceCart, SpotShot or Canister delivery methods. Note: OlyBond Classic may be used where OlyBond 500 is referenced ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. ➢ Hot asphalt: MDP = -240.0 psf (Min. 0.5-inch thick) ➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP = -117.5 psf (Min. 1.0-inch thick) ➢ GAF LRF Adhesive M (LRF-M): MDP = -232.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation) ➢ H.B. Fuller Millennium One-Step Foamable Adhesive (M-OSFA): MDP = -157.5 psf (Min. 0.5-inch thick polyisocyanurate) ➢ GAF LRF Adhesive XF (LRF-XF) or OlyBond 500 (OB500): MDP = -292.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation) ➢ OlyBond 500 (OB500): MDP = -315.0 psf (Min. 0.5-inch thick EnergyGuard RH or RN) ➢ GAF LRF Adhesive XF (LRF-XF) or OlyBond 500 (OB500): MDP = -487.5 psf (Min. 0.5-inch thick EnergyGuard RA) 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 3 of 101 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP-AA (Base/ Ply sheets, Asphalt-Applied) Base Ply: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet Hot asphalt at 25 lbs/square. Ply: One or more plies GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M BP-CA (Base/ Ply sheets, Cold-Applied) Base Ply: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Matrix 102 SBS Membrane Adhesive at 1.5 gal/sq. SBS-AA (SBS, Asphalt-Applied) Base Ply or Ply: One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth Hot asphalt at 25 lbs/square. Cap Ply: Ruberoid 30 Granule, Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth, Ruberoid Mop Granule FR, Ruberoid Mop Granule, Tri-Ply SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid Mop Plus Granule FR, Ruberoid Mop Plus Granule, Ruberoid EnergyCap Mop Plus Granule FR SBS-CA (SBS, Cold-Applied) Base Ply or Ply: Ruberoid 20 Smooth Matrix 102 SBS Membrane Adhesive at 1.5 gal/sq. Cap Ply: Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop Plus Granule FR SBS-CA1 (SBS, Cold-Applied) Base Ply: Ruberoid 20 Smooth or Ruberoid Mop Smooth 1.5 Matrix 101 Premium SBS Membrane Adhesive at 1.5 – 2.0 gal/square Cap Ply: Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop Plus Granule FR SBS-TA (SBS, Torch-Applied) Base Ply or Ply: One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Torch applied Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid EnergyCap HW Plus Granule FR APP-TA (APP, Torch-Applied) Base Ply or Ply: One or two plies Ruberoid Torch Smooth, Tri-Ply APP Smooth Membrane Cap Ply: Ruberoid Torch Granule, Tri-Ply APP Granule Membrane, Ruberoid Torch Plus Granule FR, Ruberoid EnergyCap Torch Granule FR, Ruberoid EnergyCap Torch Plus Granule FR NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 4 of 101 MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-SA (self-adhering) Base Ply or Ply: Liberty SBS Self-Adhering Base/Ply Sheet Self-adhered Cap Ply Liberty SBS Self-Adhering Cap Sheet Note: Systems with a smooth-surfaced cap ply shall be surfaced in accordance with GAF requirements, meeting the fire resistance requirements of FBC Section 1505. Refer to FBC Section 1504.8 for limitations in the use of aggregate surfacing. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A: OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE APPLICATION C-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied Hot asphalt -360.0 C-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied GAF 2-Part, 12-inch o.c. -169.0 C-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied GAF 2-Part, 12-inch o.c. -180.0 C-VB-4. GAF SA Primer GAF SA Vapor Retarder Self-adhering GAF 2-Part, 12-inch o.c. -202.5 C-VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering GAF 2-Part, 12-inch o.c. -250.0 C-VB-6. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied GAF 2-Part, 12-inch o.c. -262.5 C-VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied GAF 2-Part, 12-inch o.c. -270.0 C-VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-M, 12-inch o.c. -180.0 C-VB-9. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-M, 12-inch o.c. -202.5 C-VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied LRF-M, 12-inch o.c. -495.0 C-VB-11. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied LRF-XF, 12-inch o.c. -169.0 C-VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-XF, 12-inch o.c. -180.0 C-VB-13. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-XF, 12-inch o.c. -202.5 C-VB-14. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering LRF-XF, 12-inch o.c. -250.0 C-VB-15. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied LRF-XF, 12-inch o.c. -262.5 C-VB-16. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied LRF-XF, 12-inch o.c. -270.0 C-VB-17. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch-applied OlyBond 500, 12-inch o.c. -165.0 C-VB-18. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch-applied OlyBond 500, 12-inch o.c. -180.0 C-VB-19. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering OlyBond 500, 12-inch o.c. -187.5 C-VB-20. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane Adhesive at 1.5 gal/square OlyBond 500, 12-inch o.c. -202.5 C-VB-21. GAF SA Primer GAF SA Vapor Retarder Self-adhering OlyBond 500, 12-inch o.c. -202.5 C-VB-22. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied OlyBond 500, 12-inch o.c. -225.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 5 of 101 VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A: OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE APPLICATION C-VB-23. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch-applied OlyBond 500, 12-inch o.c. -232.5 C-VB-24. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied OlyBond 500, 12-inch o.c. -352.5 16A Vapor barrier options for over structural concrete deck followed by cellular lightweight insulating concrete carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Tables 4A through 4D applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK FOLLOWED BY CELLULAR LIGHTWEIGHT INSULATING CONCRETE PER TABLES 4A THROUGH 4D: OPTION # PRIMER VAPOR BARRIER LIGHTWEIGHT CONCRETE MDP (PSF) TYPE ATTACH LWC-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 200 psi Mearlcrete (FL13492) -82.5 LWC-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 300 psi Celcore Cellular Concrete (FL2037) -135.0 LWC-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 300 psi Elastizell (FL4994) -302.5 17 Fire barriers of FireOut™ Fire Barrier Coating, VersaShield Solo™ Fire-Resistant Slip Sheet are optional in all assemblies when overlying components are mechanically fastened. 18 The following insulations are interchangeable within the scope of this Evaluation Report: ACCEPTABLE ALTERNATES (INSULATION) Listed Product Alternate EnergyGuard Polyiso Insulation EnergyGuard NH Polyiso Insulation EnergyGuard Ultra Polyiso Insulation EnergyGuard NH Ultra Polyiso Insulation EnergyGuard HD Polyiso Insulation EnergyGuard NH HD Polyiso Insulation EnergyGuard HD Plus Polyiso Insulation EnergyGuard NH HD Plus Polyiso Insulation 19 For System Types B-1, B-2, C-1, C-2, D-1 or Type D-2, GAF SA Vapor Retarder may be installed atop the roof deck prior to installation of the insulation and roof cover. Refer to FM Loss Prevention Data Sheet 1-29 (February 2020) for design and installation limitations. 20 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 6 of 101 TABLE 1A: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-1. Min. 19/32-inch plywood or OSB; 2 ft span Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 W-2. Min. 19/32-inch plywood or OSB; 2 ft span Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 W-3. Min. 19/32-inch plywood or OSB; 2 ft span Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-4. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 W-5. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 7 of 101 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-6. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 W-7. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 W-8. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at the 4-inch lap and 6- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 W-9. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at the 4-inch lap and 6- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 8 of 101 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-10. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 W-11. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 W-12. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -60.0 W-13. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -60.0 SELF-ADHERING BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 9 of 101 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-14. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 2-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA or APP-TA SBS-SA, SBS-TA or APP- TA -45.0 VENTING SYSTEMS: W-15. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -45.0 W-16. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -45.0 W-17. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 4-inch laps and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -52.5 W-18. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 10 of 101 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-19. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -60.0 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-20. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-21. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 11 of 101 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-22. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 W-23. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 W-24. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-25. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 12 of 101 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-26. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 2-inch lap and 12-inch o.c. in three, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-27. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 2-inch lap and 12-inch o.c. in three, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-28. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec 3” Ribbed Galvalume Plate (Flat) with Drill- Tec #14 Fasteners or Drill-Tec #14 HD Fastener with Drill- Tec 3” Flat Steel Plate 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Insulation Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA SBS-AA -67.5* W-29. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8- inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 13 of 101 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-30. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8- inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -82.5 VENTING SYSTEMS: W-31. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS- AA SBS-AA, SBS-TA, APP-TA -52.5 W-32. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS- AA SBS-AA, SBS-TA, APP-TA -60.0 W-33. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8- inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS- AA SBS-AA, SBS-TA, APP-TA -82.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 14 of 101 TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-34. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation Drill-Tec #12 Fastener with Drill-Tec 3” Steel Plate 1 per 1.8 ft2 Optional additional layer(s), min. 1.5- inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -52.5 W-35. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch EnergyGuard RN Drill-Tec #12 Fastener with Drill-Tec AccuTrac Flat Plate or AccuTrac Recessed Plate 1 per 1.8 ft2 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -52.5 TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-36. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 0.75-inch, one or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Composite or EnergyGuard RA Composite Note 2 1 per 3.0 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-37. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 0.75-inch, one or more layers, any combination, loose laid Min. 1-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Note 2 1 per 2.0 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-38. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 only) 1 per 1.8 ft2 BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 SELF-ADHERING BASE PLY: W-39. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 (#14 Fasteners only) 1 per 2.0 ft2 SBS-SA (Optional) SBS- SA SBS-SA -45.0 W-40. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec #12 Fasteners and Drill-Tec 3” Steel Plates 1 per 1.8 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -52.5 W-41. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec #12 Fasteners and Drill-Tec 3” Steel Plates 1 per 1.6 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 15 of 101 TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply VENTING SYSTEMS: W-42. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.3 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0* COLD-APPLIED SYSTEMS: W-43. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 fasteners only) 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0* W-44. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 fasteners only) 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -60.0 W-45. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 fasteners only) 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -82.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 16 of 101 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-46. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-47. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -60.0 W-48. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 8-inch o.c. at min. 2-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -75.0 SELF-ADHERING BASE PLY: W-49. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Loose laid Liberty SBS Mechanically Attached Base Sheet Note 2 8-inch o.c. at min. 3-inch laps and 8-inch o.c. at two, equally spaced, staggered center rows SBS-SA None SBS-SA -97.5 TABLE 1G: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: W-50. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8- inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -45.0 W-51. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 12 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. at two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -45.0 W-52. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 12- inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-53. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 4-inch laps and 6- inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 17 of 101 TABLE 1G: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply W-54. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA, SBS-CA, APP-TA -52.5 W-55. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. in two, equally spaced, staggered center rows (Optional) APP- TA APP-TA -60.0 W-56. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 12 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8- inch o.c. at three, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -75.0 W-57. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA, SBS-CA, APP-TA -82.5 W-58. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at min. 2-inch laps and 4- inch o.c. in four (4), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -97.5 W-59. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 3-inch o.c. at min. 3-inch laps and 3- inch o.c. at five (5), equally spaced, staggered center rows. Base sheet and tin-caps shall be primed with Matrix 307 Premium Asphalt Primer prior to base ply installation (Optional) SBS- TA Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid EnergyCap HW Plus Granule FR -120.0 SELF-ADHERING BASE PLY: W-60. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Liberty SBS Mechanically Attached Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- SA SBS-SA, SBS-TA or APP-TA -37.5 W-61. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span Liberty SBS Mechanically Attached Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 3-inch laps and 8- inch o.c. in three, equally spaced, staggered center rows (Optional) SBS- SA SBS-SA, SBS-TA or APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 18 of 101 TABLE 1H: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: W-62. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at 2-inch laps and 12- inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-63. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at 4-inch laps and 16- inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA SBS-AA -52.5 W-64. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at 4-inch laps and 12- inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA SBS-AA -60.0 W-65. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at 2-inch laps and 12- inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -60.0 W-66. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 Note 2 9-inch o.c. at 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-TA SBS-TA (polyester only) -60.0 W-67. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at 4-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA SBS-AA -97.5 W-68. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 8-inch o.c. at 2-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -105.0 SELF-ADHERING BASE PLY: W-69. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span StormSafe Anchor Sheet Note 2 (Drill-Tec AccuTrac Flat Plate, Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” Recessed Steel Plate only) 9-inch o.c. at 4-inch laps and 9-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA Note: Seams sealed with TOPCOAT SB900 or Flexseal -60.0 W-70. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span Liberty SBS Mechanically Attached Base Sheet Note 2 (HD Fasteners only) 8-inch o.c. at 3-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, SBS-TA or APP- TA -60.0 TABLE 1I: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Cap Ply W-71. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span, 8d rink shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square None SBS-SA -75.0 W-72. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span, #8 x 2½” deck screws, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square None SBS-SA -90.0 W-73. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span, 8d rink shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square SBS-SA SBS-SA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 19 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: SC-1 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) One or more BP-AA, SBS- AA SBS-AA -37.5* SC-2 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.625-inch DensDeck Prime Note 2 1 per 4.0 ft2 Min. 1.5-inch EnergyGuard followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -45.0* SC-3 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.5-inch DensDeck Prime Note 2 1 per 2.7 ft2 Min. 1.5-inch EnergyGuard followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -45.0* SC-4 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.7 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* SC-5 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* SC-6 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* SC-7 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA -60.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 20 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-8 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0* SC-9 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.5 ft2 Min. 1.0-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA or SBS-TA -60.0 SC-10 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.3 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA SBS-AA, SBS-TA -60.0 SC-11 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.5 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA or SBS-TA -67.5 SC-12 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-13 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 21 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-14 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt, GAF 2-Part or OB500 BP-AA, SBS- AA None SBS-CA -45.0* SC-15 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-16 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -52.5 SC-17 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 SC-18 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-19 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-20 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-21 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 22 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-22 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 SELF-ADHERING BASE PLY: SC-23 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-EnergyGuard RH, EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-24 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-EnergyGuard RH, EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-25 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Additional layer(s), min. 0.5-inch thick base insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-26 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Additional layer(s), min. 0.5-inch thick base insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-27 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Additional layer(s), min. 1.5-inch thick base insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-28 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-29 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 23 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-30 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-31 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-32 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-33 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-34 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA SBS-TA -52.5 SC-35 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS-TA SBS-TA -60.0 SC-36 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-37 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 24 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-38 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-39 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-40 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-41 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Additional layer(s), min. 0.5-inch thick base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-42 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Additional layer(s), min. 0.5-inch thick base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-43 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Additional layer(s), min. 1.5-inch thick base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-44 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-45 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 25 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-46 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-47 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-48 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-49 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-50 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA SBS-TA -52.5 SC-51 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 VENTING SYSTEMS: SC-52 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Additional layer(s) of base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* COLD-APPLIED SYSTEMS: SC-53 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 26 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-54 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -37.5* SC-55 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -45.0* SC-56 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -45.0* SC-57 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -52.5 SC-58 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -45.0* SC-59 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -45.0* SC-60 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -52.5 HYBRID HOT/COLD-APPLIED SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 27 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-61 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-62 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.7 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-63 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 3.2 ft2 Optional additional layers base insulation followed by min.0.5-inch EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-64 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 4.0 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-65 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 3.2 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-66 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-67 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -60.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 28 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-68 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.3 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -60.0 SC-69 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-70 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-71 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -52.5 SC-72 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-73 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-74 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 29 of 101 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap CONVENTIONAL SYSTEMS: SC-75 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -45.0* SC-76 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -45.0* SC-77 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -45.0* SC-78 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -45.0* SC-79 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 SC-80 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -67.5 SELF-ADHERING BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 30 of 101 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-81 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA None SBS-SA -45.0* SC-82 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-83 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA None SBS-SA -45.0* SC-84 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25- inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-85 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-86 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation LRF-M or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-87 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 31 of 101 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-88 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -67.5 VENTING SYSTEMS: SC-89 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -45.0* SC-90 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -45.0* SC-91 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -67.5 COLD-APPLIED SYSTEMS: SC-92 Min. 22 ga., Type B, Grade 33 steel Min.0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -45.0* SC-93 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation LRF-M or OB500 SBS-CA1 None SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 32 of 101 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-94 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-CA1 None SBS-CA1 -45.0* SC-95 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-CA1 None SBS-CA1 -67.5 HYBRID HOT/COLD APPLIED SYSTEMS: SC-96 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-97 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-98 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 33 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: SC-99 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -30.0* SC-100 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -37.5* SC-101 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.625-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-102 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.13 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-103 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-104 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Note 2 1 per 4.0 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA, SBS-TA, APP-TA -45.0* SC-105 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or Structodek High Density Fiberboard Roof Insulation Note 2 1 per 2.0 ft2 SBS-AA (Optional) SBS-AA SBS-AA, SBS-TA -45.0* SC-106 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-107 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -45.0* SC-108 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 SBS-AA, SBS-TA, APP- TA (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 SC-109 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime Note 2 1 per 1.5 ft2 SBS-AA, SBS-TA, APP- TA (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 34 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-110 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.8 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -52.5 SC-111 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.8 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 SC-112 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-113 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -60.0 SC-114 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 1.0 ft2 SBS-AA (Optional) SBS-AA or SBS-TA SBS-AA, SBS-TA -67.5 SC-115 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime Note 2 1 per 1.5 ft2 SBS-TA (Optional) SBS-TA SBS-TA -67.5 SC-116 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -67.5 SC-117 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.5 ft2 SBS-TA (Optional) SBS-TA SBS-TA -75.0 SC-118 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -82.5 SC-119 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 35 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-120 Min. 20 ga., type B, Grade 33 steel or min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 1 per 1.0 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -90.0 SC-121 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.0 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -97.5 SC-122 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.5 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -97.5 SC-123 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 (#14 only) 1 per 1.0 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -105.0 SC-124 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.0 ft2 APP-TA (Optional) APP-TA APP-TA -105.0 SC-125 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.0 ft2 SBS-TA (Optional) SBS-TA SBS-TA -120.0 SC-126 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 1 per 1.0 ft2 SBS-TA (Optional) SBS-TA SBS-TA -127.5 SELF-ADHERING BASE PLY: SC-127 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, SBS-TA, APP-TA -30.0* SC-128 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 4.0 ft2 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, SBS-TA, APP-TA -37.5* SC-129 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 36 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-130 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.7 ft2 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, SBS-TA, APP-TA -45.0* SC-131 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-132 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-133 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-134 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-135 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-136 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-137 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-138 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-139 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA SBS-TA -60.0 SC-140 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-141 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 1.5 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 37 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-142 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-143 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0 SC-144 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0 SC-145 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -67.5 SC-146 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -67.5 VENTING SYSTEMS: SC-147 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -37.5* SC-148 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-149 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-150 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RH Note 2 1 per 2.9 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-151 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Ultra Note 2 1 per 3.2 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-152 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.5-inch EnergyGuard RA Note 2 1 per 4.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA -45.0* SC-153 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 3.2 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 38 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-154 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per 3.2 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-155 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per 4.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-AA -45.0* SC-156 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -52.5 SC-157 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RH Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -52.5 SC-158 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.8 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 SC-159 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Ultra Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 SC-160 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 SC-161 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.5 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -67.5 SC-162 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -67.5 SC-163 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.5 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -75.0 SC-164 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Ultra Note 2 1 per 1.5 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 39 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-165 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Note 2 1 per 1.5 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA (ASTM D6164, polyester only) -82.5 SC-166 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.6 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -82.5 SC-167 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -82.5 SC-168 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -97.5 COLD-APPLIED SYSTEMS: SC-169 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 2.0 ft2 BP-CA None SBS-CA -45.0* SC-170 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 SBS-CA None SBS-CA -45.0* SC-171 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0* SC-172 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation Note 2 1 per 2.9 ft2 SBS-CA1 None SBS-CA1 -45.0* SC-173 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0* SC-174 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1.5-inch Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -45.0* SC-175 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (AccuTrac Flat Plates only) 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 40 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-176 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -60.0 SC-177 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -67.5 SC-178 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -67.5 SC-179 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -67.5 HYBRID HOT/COLD-APPLIED SYSTEMS: SC-180 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -45.0* SC-181 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (AccuTrac Flat Plates) 1 per 1.3 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -52.5 SC-182 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -60.0 SC-183 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -82.5 SC-184 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -90.0 SC-185 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.5 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 41 of 101 TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SELF-ADHERING BASE PLY: SC-186 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.625-inch DensDeck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with GAF SA Vapor Retarder, self-adhered Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* COLD-APPLIED BASE PLY: SC-187 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.625-inch DensDeck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with GAF SA Vapor Retarder, self-adhered Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -45.0* TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-3: BONDED AND MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Adhesive & Fasteners (Notes 6,7,8,11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: SC-188 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: OB500 Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 SC-189 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: LRF-XF Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 SELF-ADHERING BASE PLY: SC-190 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: OB500 Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 SC-191 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: LRF-XF Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 42 of 101 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply CONVENTIONAL SYSTEMS: SC-192 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 24-inch o.c. at min. 2-inch laps and 24-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -30.0* SC-193 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 18-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -37.5* SC-194 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 18-inch o.c. at min. 2-inch laps and 18-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -45.0* SC-195 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 12-inch o.c. at min. 2-inch laps and 18-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-196 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 12-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-AA SBS-AA, SBS-TA -45.0* SC-197 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation. Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth Note 2 18-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -45.0* SC-198 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3.5-inch laps BP-AA, SBS- AA SBS-AA -45.0* SC-199 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 Off-centered in the lap by 0.5-inch towards the sheet-edge and spaced 18-inch o.c. within the min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* SC-200 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill- Tec #12 (steel only) or #14 18-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 43 of 101 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply SC-201 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid HW Smooth Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 12-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* SC-202 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth Note 2 12-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -52.5 SC-203 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 Off-centered in the lap by 0.5-inch towards the sheet-edge and spaced 12-inch o.c. within the min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -52.5 SC-204 Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2-3/8 in. Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plates with Drill-Tec XHD Off-centered in the lap by 0.25- inch towards the sheet-edge and spaced 12-inch o.c. within the min. 5-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -67.5 SC-205 Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill- Tec XHD 12-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -67.5 SC-206 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-AA SBS-AA, SBS-TA -82.5 SC-207 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP- TA SBS-TA, APP-TA -82.5 SC-208 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Note 2 (Drill-Tec 3” Standard Steel Plate; Drill-Tec ASAP 3S (steel) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate only) 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP- TA SBS-TA, APP-TA -82.5 SC-209 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3.25-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 44 of 101 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply SC-210 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth Note 2 6-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -112.5 SC-211 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-TA SBS-TA -150.0 SC-212 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec #14 Fasteners with Drill-Tec 2 3/8 in. Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plates 6-inch o.c. at min. 3.25-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows SBS-TA SBS-TA -150.0 SC-213 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Note 2 (Drill-Tec 3” Standard Steel Plate; Drill-Tec ASAP 3S (steel) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate only) 6-inch o.c. at min. 3.5-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows (Optional) Ruberoid HW Smooth SBS-TA -150.0 SELF-ADHERING BASE PLY: SC-214 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Mechanically Attached Base Sheet Note 2 12-inch o.c. at min. 3.5-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA, SBS- SA-T, SBS-TA or APP-TA SBS-SA, SBS-TA or APP-TA -30.0* SC-215 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Mechanically Attached Base Sheet Note 2 9-inch o.c. at min. 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -37.5 SC-216 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Self-Adhering Base/Ply Sheet Note 2 12-inch o.c. at min. 3.5-inch laps and 18-inch o.c. in one center row (Optional) SBS-SA SBS-SA -45.0* COLD-APPLIED SYSTEMS: SC-217 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3-inch laps None SBS-CA or SBS-CA1 -30.0* SC-218 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid 20 Smooth Note 2 12-inch o.c. at min. 3-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows None SBS-CA or SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 45 of 101 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply SC-219 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows None SBS-CA -45.0* SC-220 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 24-inch o.c. at min. 3-inch laps and 24-inch o.c. in two, equally spaced, staggered center rows None SBS-CA or SBS-CA1 -45.0 SC-221 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-CA at 2.0 gal/sq. SBS-CA at 2.0 gal/sq. -82.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 46 of 101 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY C-1. Primed structural concrete Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -140.0 C-2. Primed structural concrete Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-3. Primed structural concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-4. Primed structural concrete Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA SBS-AA, SBS-TA or APP-TA -270.0 C-5. Structural concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-6. Structural concrete Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-TA (Optional) One or more SBS- TA SBS-TA -245.0 C-7. Structural concrete Min. 0.25-inch DensDeck Prime LRF-XF SBS-TA (Optional) One or more SBS- TA SBS-TA -300.0 C-8. Structural concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-9. Structural concrete Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) One or more SBS- TA SBS-TA -300.0 SELF-ADHERING BASE PLY WITH BASE INSULATION LAYER ONLY C-10. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP- TA -90.0 C-11. Primed structural concrete Min. 1.5-inch EnergyGuard RN Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 C-12. Primed structural concrete Min. 1.5-inch EnergyGuard RA Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-13. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5 C-14. Structural concrete Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -167.5 C-15. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -180.0 C-16. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -180.0 C-17. Structural concrete Min. 1.5-inch EnergyGuard RN GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 47 of 101 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-18. Structural concrete Min. 1.5-inch EnergyGuard RA GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-19. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-20. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5 C-21. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -180.0 C-22. Structural concrete Min. 0.5-inch EnergyGuard Ultra LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-23. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -285.0 C-24. Structural concrete Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-25. Structural concrete Min 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0 C-26. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 C-27. Structural concrete Min. 0.25-inch DensDeck OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -122.5 C-28. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5 C-29. Structural concrete Min. 1-inch EnergyGuard RN OB 500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -162.5 C-30. Structural concrete Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -167.5 C-31. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-32. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -285.0 VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY C-33. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -150.0 C-34. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 48 of 101 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-35. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -150.0 C-36. Primed structural concrete Min. 0.5-inch EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet SBS-AA SBS-AA -172.5 C-37. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -172.5 C-38. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-TA or APP-TA -172.5 C-39. Primed structural concrete Min. 1-inch EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-AA -292.5 COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY C-40. Structural concrete Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF SBS-CA1 None SBS-CA1 -60.0 C-41. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 SBS-CA1 None SBS-CA1 -60.0 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-42. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA (Optional) BP-AA SBS-AA or SBS-TA -112.5 C-43. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck Prime Hot asphalt APP-TA (Optional) APP-TA APP-TA -127.5 C-44. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, EnergyGuard Perlite Recover Board, min. 0.75-inch EnergyGuard Perlite Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 49 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-45. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -172.5 C-46. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -187.5 C-47. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-48. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA (Optional) SBS-TA SBS-TA -232.5 C-49. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -240.0 C-50. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 C-51. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA SBS-AA, SBS- TA -255.0 C-52. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA SBS-AA, SBS- TA or APP-TA -270.0 C-53. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -307.5 C-54. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 50 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-55. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 C-56. Structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-57. Structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -232.5 C-58. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck or DensDeck Prime GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 C-59. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 C-60. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 C-61. Structural concrete Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, primed with Matrix 307 Premium Asphalt Primer LRF-XF SBS-TA (Optional) SBS-TA SBS-TA -210.0 C-62. Structural concrete Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-63. Structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -232.5 C-64. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 C-65. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -240.0 C-66. Structural concrete Min. 1.5-inch EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-TA (Optional) SBS-TA SBS-TA -300.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 51 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-67. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -150.0 C-68. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -165.0 C-69. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 C-70. Structural concrete Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, primed with Matrix 307 Premium Asphalt Primer OB500 SBS-TA (Optional) SBS-TA SBS-TA -210.0 C-71. Structural concrete Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-72. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -240.0 C-73. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) SBS-TA SBS-TA -300.0 SELF-ADHERING BASE PLY WITH POLYISOCYANURATE BASE INSULATION LAYER C-74. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-75. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -180.0 C-76. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) GAF 2-Part SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -180.0 C-77. Structural concrete Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 52 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-78. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) LRF-M SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-79. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M (Optional) Additional layer(s) base insulation LRF-M SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-80. Structural concrete Min. 1.5-inch EnergyGuard RH LRF-XF Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 C-81. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-82. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-83. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-84. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-85. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -270.0 C-86. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -285.0 C-87. Structural concrete Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 C-88. Structural concrete Min. 1-inch EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -120.0 C-89. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -122.5 C-90. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-91. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -167.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 53 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-92. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-93. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-94. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -270.0 C-95. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -285.0 VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-96. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-97. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-98. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-99. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-100. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-101. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-102. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -150.0 C-103. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 54 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-104. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -172.5 C-105. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -240.0 C-106. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -240.0 C-107. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-108. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-109. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-110. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-111. Structural concrete Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -172.5 C-112. Structural concrete Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -172.5 C-113. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -180.0 C-114. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -180.0 C-115. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck or DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 55 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-116. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck or DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -240.0 C-117. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-118. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-119. Structural concrete Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -172.5 C-120. Structural concrete Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -172.5 C-121. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -180.0 C-122. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -180.0 C-123. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -240.0 C-124. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -240.0 C-125. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-126. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-127. Structural concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 56 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-128. Structural concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-129. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-130. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-131. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-132. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-133. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-CA1 None SBS-CA1 -127.5 C-134. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -172.5 C-135. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-M, M- OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -97.5 C-136. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-XF Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-XF SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -97.5 C-137. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-CA1 None SBS-CA1 -127.5 C-138. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 57 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-139. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0 C-140. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -97.5 C-141. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 C-142. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 HYBRID COLD/HOT-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-143. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -255.0 C-144. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -180.0 C-145. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -240.0 C-146. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -180.0 C-147. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -240.0 C-148. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 C-149. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 CONVENTIONAL SYSTEMS WITH POLYSTYRENE BASE INSULATION LAYER: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 58 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-150. Structural concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 C-151. Structural concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 C-152. Structural concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 C-153. Structural concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 C-154. Structural concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -240.0 C-155. Structural concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -240.0 C-156. Structural concrete Min. 1.0-inch Foamular 250 or 2.0-inch STYROFOAM Deckmate Plus FA OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -240.0 C-157. Structural concrete Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -277.5 SELF-ADHERING BASE PLY WITH POLYSTYRENE BASE INSULATION LAYER: C-158. Structural concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -87.5 C-159. Structural concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with D41 primer GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -87.5 C-160. Structural concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-161. Structural concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with D41 primer GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -180.0 C-162. Structural concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with D41 primer GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -240.0 C-163. Structural concrete Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 59 of 101 TABLE 3C: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: C-164. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer APP-TA (Optional) APP-TA APP-TA -90.0 C-165. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer None None SBS-TA -283.1 C-166. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA, SBS-AA BP-AA, SBS-AA SBS-AA -442.5 C-167. Structural concrete (Optional) Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-TA (Optional) SBS-TA SBS-TA -465.0 SELF-ADHERING BASE PLY: C-168. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -72.5 C-169. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -140.0 VENTING SYSTEMS: C-170. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA -185.0 COLD-APPLIED SYSTEMS: C-171. Structrual concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA, BP-CA, SBS-CA (Optional) SBS-CA SBS-CA -307.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 60 of 101 TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CELCORE (FL2037): LWC-1. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-2. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-3. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-4. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-5. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -222.5 LWC-6. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -222.5 ELASTIZELL (FL4994): LWC-7. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-8. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-9. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -222.5 LWC-10. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -222.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 61 of 101 TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-11. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-12. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-13. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-14. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-15. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -225.0 LWC-16. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -225.0 LWC-17. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 2.0-inch, min. 1.0 pcf, Insulfoam OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -120.0 LWC-18. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 MEARLCRETE (FL13492): LWC-19. Structural concrete Mearlcrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 62 of 101 TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-20. Structural concrete Mearlcrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 LWC-21. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-22. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-23. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-24. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-25. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -240.0 LWC-26. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 63 of 101 TABLE 4B: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CELCORE (FL2037): CONVENTIONAL SYSTEMS: LWC-27. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0 LWC-28. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0 VENTING SYSTEMS: LWC-29. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt GAFGLAS Stratavent Perforate d Venting Base Sheet BP-AA, SBS-AA SBS-AA, SBS-TA, APP-TA -75.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 64 of 101 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CELCORE (FL2037): CONVENTIONAL SYSTEMS: LWC-30. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two (2), equally spaced, staggered center rows SBS-TA SBS-TA -45.0 LWC-31. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat Ruberoid Mop Granule, Tri-Ply SBS Granule Cap Sheet (granules down) Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. BP-AA or SBS- AA SBS-AA, SBS-TA or APP- TA -75.0 LWC-32. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 3-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. Two plies BP- AA or SBS-AA SBS-AA -75.0 HYBRID HOT/COLD-APPLIED SYSTEMS: LWC-33. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 12-inch o.c. at min. 2-inch side laps and 12-inch o.c. at three equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -45.0 LWC-34. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 9-inch o.c. at min. 2-inch side laps and 9-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -45.0 LWC-35. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7.5-inch o.c. at min. 2-inch side laps and 7.5-inch o.c. at one center row. BP-AA or SBS- AA SBS-CA1 -45.0 LWC-36. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 9-inch o.c. at min. 3-inch side laps and 18-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 65 of 101 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply LWC-37. Min. 22 ga., type B, Grade 33 steel; 5 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 3-inch side laps and 7-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -75.0 ELASTIZELL (FL4994): LWC-38. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two (2), equally spaced, staggered center rows SBS-TA SBS-TA -45.0 MEARLCRETE (FL13492): CONVENTIONAL SYSTEMS: LWC-39. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid Mop Plus Granule (granules down) Drill-Tec Locking Impact Nail 6-inch o.c. at min. 4-inch side laps and 9-inch o.c. in two, equally spaced staggered center rows. (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -45.0 LWC-40. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 7.5-inch o.c. at min. 4-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -52.5 LWC-41. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.) 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -52.5 LWC-42. Structural concrete Mearlcrete (min. 300 psi) with optional min. 1 pcf Corrugated EPS Holey Board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in two, equally spaced, staggered center rows SBS-TA SBS-TA -52.5 LWC-43. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 742 psi) min. 2-inch thick top coat GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Drill-Tec Base Sheet Fastener (1.2) 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. (Optional) BP- AA, SBS-AA SBS-AA (polyester reinforced, D6164 only) -52.5 SELF-ADHERING BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 66 of 101 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply LWC-44. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat StormSafe Anchor Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 7.5-inch o.c. at min. 4-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -52.5 PRE-EXISTENT CELLULAR LIGHTWEIGHT CONCRETE: CONVENTIONAL SYSTEMS: LWC-45. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid Mop Smooth Drill-Tec XHD Fasteners with Drill- Tec Eyehook AccuSeam Plates, Drill-Tec 2-3/8 in. Barbed XHD Plates, Dekfast Galvalume Steel Round 2-3/8” 20-Ga. Barbed Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 18-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -37.5 LWC-46. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid HW Smooth Drill-Tec XHD Fasteners with Drill- Tec 2-3/8 in. Barbed XHD Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 18-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -37.5 LWC-47. Min. 22 ga. type B, Grade 33 steel; 6’- 6”spans or min. 2,500 psi structural concrete Min 250-300 psi pre-existent cellular LWC with min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid Mop Smooth #14 HD Drill-Tec fasteners and 2” Drill-Tec Double-Barbed Round Steel Plates Fasten through LWC to structural deck 6-inch o.c. within 4-inch heat welded side laps (Optional) SBS-TA SBS-TA -52.5 LWC-48. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans, or min. 2,500 psi structural concrete Min. 340 psi, min. 2-inch thick pre- existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve an average withdrawal of 60 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.), Drill-Tec Locking Impact Nail, Drill-Tec DL 1.7” Base Sheet Fastener 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two (2), equally spaced staggered center rows. SBS-AA, SBS- TA SBS-AA, SBS-TA, APP-TA -52.5 LWC-49. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid Mop Smooth Drill-Tec XHD Fasteners with Drill- Tec Eyehook AccuSeam Plates, Drill-Tec 2-3/8 in. Barbed XHD Plates, Dekfast Galvalume Steel Round 2-3/8” 20-Ga. Barbed Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 12-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -60.0 LWC-50. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid HW Smooth Drill-Tec XHD Fasteners with Drill- Tec 2-3/8 in. Barbed XHD Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 12-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 67 of 101 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply LWC-51. Min. 22 ga. type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 250-300 psi pre-existent cellular LWC with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Note 2 Fasten through LWC to structural deck 12-inch o.c. at 4-inch side laps and 12-inch o.c. in two, equally spaced staggered center rows. (Optional) BP- AA, SBS-AA SBS-AA, SBS-TA -67.5 LWC-52. Min. 22 ga., type BV, Grade 40 steel at max. 6 ft spans or min. 2,500 psi structural concrete Re-Roof Only: Min. 210 psi, min. 2-inch thick pre-existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve an average withdrawal of 95 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.), Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in two, equally spaced, staggered center rows Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch applied SBS-TA, APP-TA -82.5 LWC-53. Min. 22 ga., type BV, Grade 40 steel at max. 6 ft spans or min. 2,500 psi structural concrete Re-Roof Only: Min. 210 psi, min. 2-inch thick pre-existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve an average withdrawal of 95 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.), Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in two, equally spaced, staggered center rows Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch applied SBS-TA, APP-TA -82.5 LWC-54. Min. 22 ga. type B, Grade 33 steel; 5-ft spans or min. 2,500 psi structural concrete Min 250 psi pre-existent cellular LWC with optional min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid HW Granule (granules down) Note 2 Fasten through LWC to structural deck 12-inch o.c. at 4-inch side laps and 12-inch o.c. in two, equally spaced staggered center rows. (Optional) SBS-TA SBS-TA (polyester, D6164 only) -97.5 TABLE 4D: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply CELCORE (FL2037): LWC-55. Structural concrete Min. 250-300 psi Celcore Cellular Concrete Matrix 307 Premium Asphalt Primer or ASTM D41 SBS-SA None SBS-TA -52.5 LWC-56. Structural concrete Min. 250-300 psi Celcore Cellular Concrete TOPCOAT PRECOTE SBS-SA None SBS-TA -100.0 ELASTIZELL (FL4994): LWC-57. Structural concrete Min. 250-300 psi Elastizell Lightweight Insulating Concrete Matrix 307 Premium Asphalt Primer or ASTM D41 SBS-SA None SBS-SA -137.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 68 of 101 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-1. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 CWF-2. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 CWF-3. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 CWF-4. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 SELF-ADHERING BASE PLY: CWF-5. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP-TA -52.5 CWF-6. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP-TA -45.0 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-7. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 69 of 101 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-8. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* CWF-9. Min. 2-inch Tectum I Plank GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 6-inch o.c. at the 3- inch lap and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA SBS-AA -60.0 CWF-10. Min. 2-inch Tectum I Plank GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 6-inch o.c. at the 3- inch lap and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation Hot asphalt Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 70 of 101 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-11. Existing Tectum (re- roof only) GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -30.0 CWF-12. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA or APP-TA -45.0* CWF-13. Existing Tectum (re- roof only) Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -60.0 CWF-14. Existing Tectum (re- roof only) Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -60.0 CWF-15. Existing Tectum (re- roof only) GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet or Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 CWF-16. Existing Tectum (re- roof only) Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -67.5 CWF-17. Min. 2-inch Tectum I Plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 6-inch o.c. at the 4-inch lap and 6-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- AA or SBS-TA SBS-AA or SBS-TA -75.0 HYBRID HOT/COLD-APPLIED SYSTEMS: CWF-18. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 2-inch lap and 9-inch o.c. at two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 71 of 101 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: G-1. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA (Optional) SBS- TA SBS-TA -190.0 SELF-ADHERING BASE PLY: G-2. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation or EnergyGuard RH OB500 (Optional) Additional layer(s) of base insulation OB500 SBS-SA None SBS-SA -87.5 G-3. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -105.0 G-4. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation or EnergyGuard RN OB500 (Optional) Additional layer(s) of base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -147.5 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: G-5. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* G-6. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* VENTING SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 72 of 101 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-7. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Min. 1.8-inch Drill-Tec Locking Impact Nail or Drill-Tec Base Sheet Fastener (1.2 in) 9-inch o.c. at the 2- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite Recover Board or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA or SBS- TA -45.0* G-8. Existing sound gypsum or gypsum plank GAFGLAS Stratavent Nailable Venting Base Sheet Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 2- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt None N/A GAFGLAS Stratavent Perforated Venting Base Sheet Two plies SBS-AA SBS-AA -45.0* TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply G-9. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Drill-Tec Polymer Gyptec Fastener with Drill-Tec Gyptec Plate 1 per 1.3 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -62.5* TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: G-10. Existing sound gypsum or gypsum plank GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -30.0 G-11. Existing sound gypsum or gypsum plank GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS- TA or APP-TA -45.0* G-12. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows SBS-TA SBS-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 73 of 101 TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply G-13. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA or APP-TA -50.0* G-14. Existing sound gypsum or gypsum plank Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -60.0 G-15. Existing sound gypsum or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -60.0 G-16. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 9-inch o.c. in three, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA or APP-TA -57.5* G-17. Existing sound gypsum or gypsum plank GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet or Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 G-18. Existing sound gypsum or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -67.5 HYBRID HOT/COLD-APPLIED SYSTEMS: G-19. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 9-inch o.c. at min. 2-inch laps and 18-inch o.c. at two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA1 -45.0* G-20. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 7.5-inch o.c. at min. 2-inch laps and 7.5-inch o.c. at one center rows BP-AA or SBS-AA SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 74 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY R-1. Existing asphaltic roof cover Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -140.0 R-2. Existing asphaltic roof cover Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-3. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-4. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA SBS-AA, SBS-TA or APP-TA -240.0 R-5. Existing granule surface cap sheet Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 R-6. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -110.0 R-7. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part, 6-inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -157.5 R-8. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-9. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part, 4-inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-10. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-11. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 6-inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-12. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-13. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 4-inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-14. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime GAF 2-Part, 4-inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -200.0 R-15. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-TA (Optional) SBS-TA SBS-TA -245.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 75 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-16. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-17. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-18. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-19. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-20. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime LRF-XF, 4- inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -200.0 R-21. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime LRF-XF SBS-TA (Optional) SBS-TA SBS-TA -245.0 R-22. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -110.0 R-23. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-24. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -120.0 R-25. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) One or more SBS-TA SBS-TA -120.0 R-26. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6- inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -157.5 R-27. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-28. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 4- inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-29. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 4- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -200.0 R-30. Existing granule surface cap sheet Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 SELF-ADHERING BASE PLY WITH BASE INSULATION LAYER ONLY R-31. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP-TA -90.0 R-32. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 76 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-33. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-34. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA or EnergyGuard RN GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-35. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-36. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-37. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-38. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-39. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 6-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -137.5 R-40. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA or EnergyGuard RN GAF 2-Part, 6-inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-41. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part, 6-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-42. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part, 6-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-43. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part, 4-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -167.5 R-44. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-45. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part, 4-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 77 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-46. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA or EnergyGuard RN GAF 2-Part, 4-inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -200.0 R-47. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 R-48. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-49. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -75.0 R-50. Existing smooth surfaced BUR or granule surface roof cover Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -75.0 R-51. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-52. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-53. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -200.0 R-54. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0 R-55. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA LRF-XF SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-56. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-57. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-58. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-59. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -137.5 R-60. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-61. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 78 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-62. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-63. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-64. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -180.0 R-65. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA LRF-XF, 4- inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -200.0 R-66. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA LRF-XF SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-67. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -97.5 R-68. Existing asphaltic roof cover or gravel- surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0 R-69. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -110.0 R-70. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-71. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN, Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-72. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-73. Existing asphaltic roof cover Min. 0.25-inch DensDeck, optionally primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-74. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 79 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-75. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-76. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-77. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -122.5 R-78. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -137.5 R-79. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-80. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN, Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-81. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN OB500, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -162.5 R-82. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -167.5 R-83. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -200.0 R-84. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0 VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY R-85. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -150.0 R-86. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS- AA SBS-TA or APP- TA -150.0 R-87. Existing smooth- or granule-surface BUR, granule-surface modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 80 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-88. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -172.5 R-89. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS- AA SBS-TA or APP- TA -172.5 R-90. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-91. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 6-inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 R-92. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -180.0 R-93. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 4-inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-94. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -75.0 R-95. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-96. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 R-97. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 4- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-98. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -225.0 R-99. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-100. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 6- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 R-101. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -180.0 R-102. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 4- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-103. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-104. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 6- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 81 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-105. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 4- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-106. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -225.0 COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY R-107. Existing mineral surface cap or asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -127.5 R-108. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -172.5 R-109. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -110.0 R-110. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -120.0 R-111. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime GAF 2-Part, 6-inch o.c. SBS-CA1 None SBS-CA1 -127.5 R-112. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 6-inch o.c. SBS-CA1 None SBS-CA1 -157.5 R-113. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 4-inch o.c. SBS-CA1 None SBS-CA1 -172.5 R-114. Existing smooth surfaced BUR or granule surface roof cover Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -75.0 R-115. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -110.0 R-116. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -120.0 R-117. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime LRF-XF, 6- inch o.c. SBS-CA1 None SBS-CA1 -127.5 R-118. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. SBS-CA1 None SBS-CA1 -157.5 R-119. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4- inch o.c. SBS-CA1 None SBS-CA1 -172.5 R-120. Existing smooth APP, mineral surface cap, asphaltic BUR or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-CA1 None SBS-CA1 -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 82 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-121. Existing smooth surfaced BUR / APP modified bitumen, granule surface roof cover or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel over structural concrete deck Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -97.5 R-122. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -110.0 R-123. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -120.0 R-124. Existing smooth APP or mineral surface cap Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 R-125. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime OB500, 6- inch o.c. SBS-CA1 None SBS-CA1 -127.5 R-126. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-CA1 None SBS-CA1 -157.5 R-127. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -165.0 R-128. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 R-129. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4- inch o.c. SBS-CA1 None SBS-CA1 -172.5 HYBRID HOT/COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY R-130. Existing mineral surface cap or asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-131. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-132. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-133. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-134. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime GAF 2-Part, 6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-135. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-136. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 4-inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-137. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 83 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-138. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-139. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime LRF-XF, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-140. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-141. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-142. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-143. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-144. Existing smooth APP or mineral surface cap Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-145. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime OB500, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-146. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-147. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -165.0 R-148. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-149. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 84 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS (BASE AND TOP LAYER INSULATION): R-150. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA (Optional) BP-AA SBS-AA or SBS- TA -112.5 R-151. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -127.5 R-152. Existing smooth- or granule- surface BUR, granule-surface modified bitumen or smooth- surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, EnergyGuard Perlite Recover Board, min. 0.75-inch EnergyGuard Perlite Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-153. Existing granule surface cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -172.5 R-154. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -172.5 R-155. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -187.5 R-156. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -225.0 R-157. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA (Optional) SBS- TA SBS-TA -232.5 R-158. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP- TA APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 85 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-159. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or Min. 1.5-inch EnergyGuard Composite or min. 0.25-inch DensDeck Prime Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 R-160. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-161. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-162. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board GAF 2-Part BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-163. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-164. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-165. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 R-166. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 4-inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 R-167. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 4-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 86 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-168. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, 4-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -200.0 R-169. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -225.0 R-170. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -232.5 R-171. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck or DensDeck Prime GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 R-172. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -75.0 R-173. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -110.0 R-174. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 87 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-175. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-176. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-177. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board LRF-XF BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-178. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-179. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 4- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 R-180. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF, 4- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -200.0 R-181. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -225.0 R-182. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -232.5 R-183. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 88 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-184. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-185. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-186. Existing asphalt BUR or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -120.0 R-187. Existing asphalt BUR or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -120.0 R-188. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -150.0 R-189. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board OB500 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-190. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -150.0 R-191. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-192. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 89 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-193. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-194. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -165.0 R-195. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -165.0 R-196. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -165.0 R-197. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -187.5 R-198. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) SBS- TA SBS-TA -200.0 R-199. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-200. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -200.0 R-201. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 SELF-ADHERING BASE PLY WITH POLYISOCYANURATE BASE INSULATION LAYER NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 90 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-202. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-203. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS- SA SBS-SA -110.0 R-204. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-205. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 6-inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-206. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -180.0 R-207. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 4-inch o.c. (Optional) Additional layer(s) base insulation GAF 2-Part SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 R-208. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 4-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 R-209. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -75.0 R-210. Existing smooth surfaced BUR or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M- OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -75.0 R-211. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -97.5 R-212. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 91 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-213. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-214. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 4- inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-215. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -225.0 R-216. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-217. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS- SA SBS-SA -110.0 R-218. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-219. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 6- inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-220. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -180.0 R-221. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 4- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 R-222. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 92 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-223. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -97.5 R-224. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -97.5 R-225. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-226. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA -110.0 R-227. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-228. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- SA SBS-TA or APP- TA -120.0 R-229. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -120.0 R-230. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-231. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-232. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 6- inch o.c. (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-233. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 93 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-234. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -165.0 R-235. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.25-inch DensDeck; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -167.5 R-236. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 4- inch o.c. (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-237. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-238. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -225.0 R-239. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (primer optional) OB500, 6- inch o.c. SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -240.0 VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-240. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-241. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-242. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-243. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-244. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 94 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-245. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -150.0 R-246. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 R-247. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -172.5 R-248. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -240.0 R-249. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -240.0 R-250. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-251. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-252. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-253. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-254. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-255. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 95 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-256. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part, 6-inch o.c. (Optional) EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-257. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part, 6-inch o.c. (Optional) EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-258. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-259. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-260. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part, 4-inch o.c. (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 R-261. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part, 4-inch o.c. (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -172.5 R-262. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -200.0 R-263. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -200.0 R-264. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-265. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-266. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 96 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-267. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-268. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 6- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-269. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 6- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-270. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-271. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-272. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 4- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 R-273. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 4- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -172.5 R-274. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -200.0 R-275. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -200.0 R-276. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 97 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-277. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-278. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-279. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-280. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-281. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-282. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500, 6- inch o.c. (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 R-283. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500, 6- inch o.c. (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -150.0 R-284. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 R-285. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -150.0 COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-286. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 98 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-287. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -127.5 R-288. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -110.0 R-289. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-CA1 None SBS-CA1 -127.5 R-290. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -157.5 R-291. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 4-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -172.5 R-292. Existing smooth surfaced BUR or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M- OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -75.0 R-293. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -110.0 R-294. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-M SBS-CA1 None SBS-CA1 -127.5 R-295. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -157.5 R-296. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -172.5 R-297. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -110.0 R-298. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF SBS-CA1 None SBS-CA1 -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 99 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-299. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -157.5 R-300. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -172.5 R-301. Existing asphaltic roof cover or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0 R-302. Existing smooth surfaced BUR / APP modified bitumen, granule surface roof cover or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel over structural concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -97.5 R-303. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -110.0 R-304. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -120.0 R-305. Existing smooth APP or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 R-306. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 R-307. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -157.5 R-308. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -165.0 R-309. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 R-310. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 100 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID HOT/COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-311. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-312. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-313. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-314. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-315. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-316. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 4-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-317. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-318. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-319. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-320. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-321. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-322. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 101 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-323. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-324. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-325. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-326. Existing smooth APP or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-327. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -165.0 R-328. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-329. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-330. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-331. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-332. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT GAF 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 Evaluation Report 01506.11.05-R30 FL5680-R30 Date of Issuance: 11/07/2005 Revision 30: 03/08/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: GAF Modified Bitumen Roof Systems for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in i ts entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 101-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 03/08/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R30 GAF Modified Bitumen Roof Systems Revision 30: 03/08/2021 Page 2 of 6 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: GAF Modified Bitumen Roof Systems, as produced by GAF, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1515.1.1 Wind resistance TAS 114, Appendix C, D or J 2011 1504.7 Impact resistance FM 4470 2016 1507.10.2 Material standard ASTM D2178 2015 1507.10.2 Material standard ASTM D4601 2012 1507.10.2 Material standard ASTM D4897 2009 1507.11.2 Material standard ASTM D6163 2015 1507.11.2 Material standard ASTM D6164 2011 1507.11.2 Material standard ASTM D6222 2011 3. REFERENCES: Entity Examination Reference Date Entity Examination Reference Date ACRC (TST4671) TAS 114 ACRC 06-041 11/10/2006 FM (TST1867) FM 4470/4474 797-07038-267 01/10/2012 ACRC (TST4671) TAS 114 ACRC 06-042 11/14/2006 FM (TST1867) FM 4470/4474 797-07073-267 01/19/2012 ACRC (TST4671) TAS 114 ACRC 06-043 11/16/2006 FM (TST1867) FM 4470/4474 3038128 07/26/2010 ACRC (TST4671) TAS 114 ACRC 006-044 11/16/2006 FM (TST1867) FM 4470/4474 3040738 11/16/2010 ACRC (TST4671) TAS 114 ACRC 06-048 12/21/2006 FM (TST1867) FM 4470/4474 3041535 06/08/2011 ACRC (TST4671) TAS 114 ACRC 06-049 12/22/2006 FM (TST1867) FM 4470/4474 3044688 03/01/2012 ACRC (TST4671) TAS 114 ACRC 06-050 12/28/2006 FM (TST1867) FM 4470/4474 797-07198-267 03/01/2012 ACRC (TST4671) TAS 114 ACRC 07-006 01/17/2007 FM (TST1867) FM 4470/4474 3044688 (Re-Issue) 03/16/2012 ACRC (TST4671) TAS 114 ACRC 07-018 04/20/2007 FM (TST1867) FM 4470/4474 3044541 04/04/2012 ACRC (TST4671) TAS 114 ACRC 07-028 05/08/2007 FM (TST1867) FM 4470/4474 3044862 05/11/2012 ACRC (TST4671) TAS 114 ACRC 07-030 05/09/2007 FM (TST1867) FM 4470/4474 3043900 08/16/2012 ACRC (TST4671) TAS 114 ACRC 07-032 05/10/2007 FM (TST1867) FM 4470/4474 3046280 08/22/2012 ACRC (TST4671) TAS 114 ACRC 07-033 05/10/2007 FM (TST1867) FM 4470/4474 3046388 09/24/2012 ACRC (TST4671) TAS 114 ACRC 07-041 08/31/2007 FM (TST1867) FM 4470/4474 3041769 09/27/2012 ACRC (TST4671) TAS 114 ACRC 07-044 09/05/2007 FM (TST1867) FM 4470/4474 3046403 09/28/2012 ACRC (TST4671) TAS 114 ACRC 07-047 09/07/2007 FM (TST1867) FM 4470/4474 3046054 12/21/2012 ACRC (TST4671) TAS 114 ACRC 07-081 01/10/2008 FM (TST1867) FM 4470/4474 3046081 02/13/2013 ACRC (TST4671) TAS 114 ACRC 07-082 01/11/2008 FM (TST1867) FM 4470/4474 797-08216-267 04/11/2013 ACRC (TST4671) TAS 114 ACRC 08-024 04/18/2008 FM (TST1867) FM 4470/4474 3048122 04/29/2013 ACRC (TST4671) TAS 114 ACRC 08-034 05/19/2008 FM (TST1867) FM 4470/4474 3047104 05/10/2013 ACRC (TST4671) TAS 114 ACRC 08-044 07/01/2008 FM (TST1867) FM 4470/4474 797-08263-267 05/23/2013 ACRC (TST4671) TAS 114 ACRC 11-043 08/08/2011 FM (TST1867) FM 4470/4474 797-08264-267 05/23/2013 ACRC (TST4671) TAS 114 ACRC 11-046 08/09/2011 FM (TST1867) FM 4470/4474 3047237 07/15/2013 ACRC (TST4671) TAS 114 ACRC 11-048 08/10/2011 FM (TST1867) FM 4470/4474 797-08670-267 09/16/2013 ACRC (TST4671) TAS 114 ACRC 11-049 08/10/2011 FM (TST1867) FM 4470/4474 797-08873-267 11/26/2013 ACRC (TST4671) TAS 114 ACRC 11-050 08/11/2011 FM (TST1867) FM 4470/4474 3048871 12/11/2013 ACRC (TST4671) TAS 114 ACRC 11-051 08/11/2011 FM (TST1867) FM 4470/4474 3048066 12/13/2013 ACRC (TST4671) TAS 114 ACRC 11-052 08/12/2011 FM (TST1867) FM 4470/4474 797-09016-267 12/17/2013 ACRC (TST4671) TAS 114 ACRC 11-053 08/17/2011 FM (TST1867) FM 4470/4474 3048496 12/19/2013 ACRC (TST4671) TAS 114 ACRC 11-054 08/17/2011 FM (TST1867) FM 4470/4474 3049601 01/29/2014 ACRC (TST4671) TAS 114 ACRC 12-015 04/24/2012 FM (TST1867) FM 4470/4474 797-09984-267 10/28/2014 ACRC (TST4671) TAS 114 ACRC 12-026 05/10/2012 FM (TST1867) FM 4470/4474 797-09987-267 10/28/2014 ACRC (TST4671) TAS 114 ACRC 12-034 08/10/2012 FM (TST1867) FM 4470/4474 797-10017-267 11/06/2014 ACRC (TST4671) TAS 114 ACRC 12-035 08/13/2012 FM (TST1867) FM 4470/4474 RR205568 06/15/2016 ACRC (TST4671) TAS 114 ACRC 16-002 03/04/2016 FM (TST1867) FM 4470/4474 RR205474 08/31/2016 ERD (TST6049) TAS 114/FM4474 01880.09.03 09/10/2003 FM (TST1867) FM 4470 / 4474 3058483 12/09/2016 ERD (TST6049) TAS 114/FM4474 01516.04.06 04/20/2006 FM (TST1867) FM 4470 / 4474 RR208244 02/02/2017 ERD (TST6049) TAS 114/FM4474 4482.10.97-1 12/02/2006 FM (TST1867) FM 4470 / 4474 RR208306 02/02/2017 ERD (TST6049) TAS 114/FM4474 G4280LAB.10.06-R1 12/06/2007 FM (TST1867) FM 4470 / 4474 RR208456 02/13/2017 ERD (TST6049) ASTM D6164 (CA-S) G6850.08.08-1 08/29/2008 FM (TST1867) FM 4470 / 4474 3062588 (PLA) 08/01/2017 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R30 GAF Modified Bitumen Roof Systems Revision 30: 03/08/2021 Page 3 of 6 Entity Examination Reference Date Entity Examination Reference Date ERD (TST6049) ASTM D6222 (CA-S) G6850.10.08 10/06/2008 FM (TST1867) FM 4470 / 4474 Letter 02/13/2018 ERD (TST6049) ASTM D6222 (GA) G6850.11.08 11/05/2008 FM (TST1867) FM 4470 / 4474 3061784 07/25/2018 ERD (TST6049) ASTM D6163 (GA) G34140.04.11-2 04/25/2011 FM (TST1867) FM 4470 / 4474 3055904 10/25/2018 ERD (TST6049) ASTM D4601 (GA) G34140.04.11-4 04/25/2011 FM (TST1867) FM 4470 / 4474 RR215191-267 11/07/2018 ERD (TST6049) ASTM D4897 (GA) G34140.04.11-5 04/25/2011 FM (TST1867) FM 4470 PR452971 02/19/2020 ERD (TST6049) TAS 114/FM4474 G36780.07.11-R1 07/18/2011 FM (TST1867) FM 4474 PR455417 12/23/2020 ERD (TST6049) ASTM D6222 (GA) G43190.11.13-1 11/15/2013 FM (TST1867) FM 4474 PR458073 04/08/2021 ERD (TST6049) ASTM D6163 (GA) G40630.01.14-1 01/06/2014 IRT (TST7408) TAS 114 00001 03/30/2000 ERD (TST6049) ASTM D6164 (GA) G40630.01.14-2A-1-R1 01/07/2014 IRT (TST7408) TAS 114 00002 03/30/2000 ERD (TST6049) ASTM D6164 (GA) G40630.01.14-2B-R2 01/07/2014 IRT (TST7408) TAS 114 01-039 01/24/2002 ERD (TST6049) ASTM D6164 (GA) G40630.01.14-2C 01/07/2014 IRT (TST7408) TAS 114 02-005 01/24/2002 ERD (TST6049) ASTM D4601 (IN) G43180.01.14-1 01/10/2014 IRT (TST7408) TAS 114 02-014 03/26/2002 ERD (TST6049) ASTM D6222 (IN) G43180.03.14 03/03/2014 IRT (TST7408) TAS 114 03-003 04/21/2003 ERD (TST6049) ASTM D6222 (CA-S) G43190.03.14-1 03/06/2014 IRT (TST7408) TAS 114 03-004 04/21/2003 ERD (TST6049) ASTM D6222 (CA-S) G43190.03.14-2 03/06/2014 IRT (TST7408) TAS 114 04-008 01/26/2004 ERD (TST6049) ASTM D6222 (GA) G43190.05.14-R1 05/14/2014 ITS (TST1558) TAS 114 H9486.03-109-18 09/17/2018 ERD (TST6049) ASTM D6163 (CA-S) G46160.09.14-2A 09/09/2014 ITS (TST1558) TAS 114 H9486.04-109-18 09/17/2018 ERD (TST6049) ASTM D6164 (GA) G46160.09.14-3A 09/09/2014 M-D (CER1592) TAS 114 13-0617.20 09/05/2013 ERD (TST6049) ASTM D6164 (GA) G46160.09.14-3B 09/09/2014 M-D (CER1592) TAS 114 13-0307.02 09/26/2013 ERD (TST6049) ASTM D6164 (GA) G46160.09.14-3C 09/09/2014 M-D (CER1592) TAS 114 13-1007.09 01/30/2014 ERD (TST6049) ASTM D6164 (GA) G46160.12.14-3E 12/29/2014 NEMO (TST6049) ASTM D6222 (GA) G30250.02.10-2-R1 02/11/2010 ERD (TST6049) TAS 114/FM4474 SC8580.11.15-3 11/09/2015 NEMO (TST6049) ASTM D6164 (CA-S) G33470.01.11-R1 01/13/2011 ERD (TST6049) TAS 114/FM4474 SC8580.01.16-1 01/20/2016 NEMO (TST6049) ASTM D6163 (GA) G34140.04.11-2-R1 04/25/2011 ERD (TST6049) ASTM D4601 (GA) GAF-SC13285.02.17-2 02/08/2017 NEMO (TST6049) ASTM D6222 (GA) G40620.07.12-2-R1 07/17/2012 ERD (TST6049) ASTM D6163 (GA) G46160.02.15-2D-1 02/09/2017 NEMO (TST6049) ASTM D6163 (GA) 4S-GAF-18-001.11.18 11/06/2018 ERD (TST6049) ASTM D6164 (GA) GAF-SC13285.03.17-5 03/23/2017 NEMO (TST6049) ASTM D2178 (GA) 4S-GAF-18-001.01.19-1 01/02/2019 ERD (TST6049) ASTM D6164 (GA) GAF-SC13105.03.17-R1 04/04/2017 NEMO (TST6049) ASTM D6222 (IN) 4S-GAF-18-001.03.19.A 03/13/2019 ERD (TST6049) D4601/D1970 (IN) GAF-SC16440.12.17 12/31/2017 NEMO (TST6049) ASTM D6164 (AR) 4q-GAF-19-SSMBB-01A 04/08/2019 ERD (TST6049) TAS 114/FM4474 GAF-SC16825.12.17-1 12/31/2017 NEMO (TST6049) ASTM D6163 (AR) 4q-GAF-19-SSMBB-02A 04/08/2019 F-TEC (TST7393) TAS 114 08-050187 04/28/2008 NEMO (TST6049) FM 4474 4L-GAF-18-002.05.19.A 05/29/2019 F-TEC (TST7393) TAS 114 08-050188 04/28/2008 PRI (TST5878) FM 4470/4474 GAF-434-02-01 09/16/2013 F-TEC (TST7393) TAS 114 08-070077 07/25/2008 PRI (TST5878) FM 4470/4474 GAF-434-02-03 09/16/2013 F-TEC (TST7393) TAS 114 08-070084 07/25/2008 PRI (TST5878) FM 4470/4474 GAF-434-02-04 09/16/2013 F-TEC (TST7393) TAS 114 08-050181R 04/01/2009 PRI (TST5878) FM 4470/4474 GAF-436-02-02 03/06/2014 F-TEC (TST7393) TAS 114 08-050186 10/14/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-03 03/06/2014 F-TEC (TST7393) TAS 114 08-070126 10/14/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-04 03/06/2014 F-TEC (TST7393) TAS 114 08-070122 10/14/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-05 03/06/2014 F-TEC (TST7393) TAS 114 08-070127 10/14/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-08 03/06/2014 F-TEC (TST7393) TAS 114 08-080077 11/17/2008 PRI (TST5878) FM 4470/4474 GAF-436-02-09 03/06/2014 FM (TST1867) FM 4470 1B9A8.AM 09/04/1997 PRI (TST5878) FM 4470/4474 GAF-549-02-01 08/08/2014 FM (TST1867) FM 4470 3007500 06/15/2000 PRI (TST5878) FM 4470/4474 GAF-549-02-02 08/08/2014 FM (TST1867) FM 4470 3005640 11/09/2000 PRI (TST5878) FM 4470/4474 GAF-559-02-01 10/16/2014 FM (TST1867) FM 4470 3008178 12/27/2000 PRI (TST5878) FM 4470/4474 GAF-559-02-05 10/16/2014 FM (TST1867) FM 4470 3010215 03/01/2001 PRI (TST5878) FM 4470/4474 GAF-559-02-06 10/16/2014 FM (TST1867) FM 4470 3009788 03/28/2001 PRI (TST5878) FM 4470/4474 GAF-559-02-07 10/16/2014 FM (TST1867) FM 4470 3011140 08/14/2001 PRI (TST5878) Criticality GAF-559-02-08 10/16/2014 FM (TST1867) FM 4470 3013614 05/06/2002 PRI (TST5878) FM 4470/4474 GAF-559-02-09 10/16/2014 FM (TST1867) FM 4470 3013788 01/10/2003 PRI (TST5878) FM 4470/4474 GAF-559-02-11 10/16/2014 FM (TST1867) FM 4470 3014547 05/22/2003 PRI (TST5878) FM 4470/4474 GAF-559-02-12 10/16/2014 FM (TST1867) FM 4470 3014692 08/05/2003 PRI (TST5878) FM 4470/4474 GAF-559-02-13 10/16/2014 FM (TST1867) FM 4470 3014960 03/05/2004 PRI (TST5878) FM 4470/4474 GAF-559-02-14 10/16/2014 FM (TST1867) FM 4470/4474 3017250 04/05/2004 PRI (TST5878) FM 4470/4474 GAF-559-02-15 10/16/2014 FM (TST1867) FM 4470/4474 3022139 05/26/2005 PRI (TST5878) FM 4470/4474 GAF-559-02-16 10/16/2014 FM (TST1867) FM 4470/4474 3022508 07/20/2005 PRI (TST5878) FM 4470/4474 GAF-559-02-17 10/16/2014 FM (TST1867) FM 4470/4474 3025023 12/14/2005 PRI (TST5878) FM 4470/4474 GAF-559-02-18 10/16/2014 FM (TST1867) FM 4470/4474 797-02095-267 04/26/2006 PRI (TST5878) FM 4470/4474 GAF-559-02-04-R1 03/04/2015 FM (TST1867) FM 4470/4474 3023458 07/18/2006 PRI (TST5878) FM 4470/4474 GAF-559-02-19 04/17/2015 FM (TST1867) FM 4470/4474 3028039 09/11/2006 PRI (TST5878) FM 4470/4474 GAF-746-02-05 12/15/2016 FM (TST1867) FM 4470/4474 3024805 11/20/2006 PRI (TST5878) FM 4470/4474 GAF-746-02-06 12/15/2016 FM (TST1867) FM 4470/4474 3032388 10/30/2008 PRI (TST5878) FM 4470/4474 GAF-755-02-01 02/02/2017 FM (TST1867) FM 4470/4474 3032695 10/30/2008 PRI (TST5878) FM 4470/4474 GAF-755-02-02 02/02/2017 FM (TST1867) FM 4470/4474 3032943 11/06/2008 PRI (TST5878) FM 4470/4474 GAF-755-02-03 02/02/2017 FM (TST1867) FM 4470/4474 3032811 12/11/2008 PRI (TST5878) FM 4470/4474 GAF-755-02-04 02/02/2017 FM (TST1867) FM 4470/4474 3033719 01/16/2009 PRI (TST5878) ASTM D2178 (AL) MSA-039-02-01 09/27/2017 FM (TST1867) FM 4470/4474 3035864 06/03/2009 PRI (TST5878) ASTM D2178 (AL) MSA-039-02-02 09/27/2017 FM (TST1867) FM 4470/4474 3032172 06/12/2009 PRI (TST5878) FM 4470/4474 GAF-747-02-04 09/13/2018 FM (TST1867) FM 4470/4474 3035140 08/10/2009 PRI (TST5878) FM 4470/4474 GAF-747-02-05 09/13/2018 FM (TST1867) FM 4470/4474 3036225 08/10/2009 PRI (TST5878) Criticality GAF-743-02-01 09/14/2018 FM (TST1867) FM 4470 (s/s) 3036980 08/14/2009 PRI (TST5878) Criticality GAF-743-02-02 09/14/2018 FM (TST1867) FM 4470/4474 3034978 09/17/2009 PRI (TST5878) FM 4470/4474 GAF-743-02-03 09/21/2018 FM (TST1867) FM 4470/4474 797-05447-267 04/13/2010 PRI (TST5878) FM 4470/4474 GAF-743-02-04 09/21/2018 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R30 GAF Modified Bitumen Roof Systems Revision 30: 03/08/2021 Page 4 of 6 Entity Examination Reference Date Entity Examination Reference Date FM (TST1867) FM 4470/4474 797-05487-267 05/12/2010 PRI (TST5878) FM 4470/4474 GAF-743-02-05 09/21/2018 FM (TST1867) FM 4470/4474 797-05550-267 05/25/2010 PRI (TST5878) FM 4470/4474 GAF-743-02-06 09/21/2018 FM (TST1867) FM 4470/4474 797-05538-267 05/25/2010 PRI (TST5878) FM 4470/4474 GAF-743-02-08 09/21/2018 FM (TST1867) FM 4470/4474 797-05594-267 06/01/2010 PRI (TST5878) FM 4470/4474 GAF-765-02-02 09/21/2018 FM (TST1867) FM 4470/4474 797-05695-267 07/15/2010 PRI (TST5878) FM 4470/4474 GAF-901-02-01 02/27/2019 FM (TST1867) FM 4470/4474 797-05683-267 07/21/2010 PRI (TST5878) FM 4470/4474 GAF-901-02-02 02/27/2019 FM (TST1867) FM 4470/4474 797-05687-267 07/21/2010 PRI (TST5878) FM 4470/4474 GAF-903-02-01 08/15/2019 FM (TST1867) FM 4470/4474 797-05748-267 08/10/2010 PRI (TST5878) Criticality 376T0006-1 09/06/2019 FM (TST1867) FM 4470/4474 3040738 11/16/2010 PRI (TST5878) Criticality 376T0006-3 09/06/2019 FM (TST1867) FM 4470/4474 3036960 11/30/2010 PRI (TST5878) FM 4470/4474 376T0042 12/20/2019 FM (TST1867) FM 4470/4474 797-06129-267 01/13/2011 PRI (TST5878) FM 4474 376T0063 04/02/2020 FM (TST1867) FM 4470/4474 797-06177-267 03/16/2011 PRI (TST5878) FM 4470, impact 376T0064 04/02/2020 FM (TST1867) FM 4470/4474 797-06540-267 06/21/2011 UL (QUA9625) QA Service confirmation 09/29/2020 FM (TST1867) FM 4470/4474 797-06800-267 09/29/2011 UL (QUA9625) QA Florida BCIS Current 4. PRODUCT DESCRIPTION: This Evaluation Report covers GAF Modified Bitumen Roof Systems installed in accordance with GAF published installation instructions and the Limitations / Conditions of Use herein. TABLE 1: EVALUATED MEMBRANES Type Product Material Standard Plant(s) Reference Type Grade Base Sheets GAFGLAS® #75 Base Sheet ASTM D4601 II N/A CA-F, GA Tri-Ply® #75 Base Sheet ASTM D4601 II N/A CA-F, GA GAFGLAS® #80 Ultima™ Base Sheet ASTM D4601 II N/A GA Liberty™ SBS Mechanically Attached Base Sheet ASTM D4601 II N/A IN GAFGLAS® Stratavent® Nailable Venting Base Sheet ASTM D4897 II N/A CA-F, GA GAFGLAS® Stratavent® Perforated Venting Base Sheet ASTM D4897 II N/A CA-F, GA StormSafe™ Anchor Sheet not codified Ontario Ply Sheets GAFGLAS® Ply 4 ASTM D2178 IV N/A CA-F, GA GAFGLAS® Ply 4 M ASTM D2178 IV N/A AL Tri-Ply® Ply 4 Ply Sheet ASTM D2178 IV N/A CA-F, GA GAFGLAS® FlexPly™ 6 ASTM D2178 VI N/A CA-F, GA GAFGLAS® FlexPly™ 6 M ASTM D2178 VI N/A AL Liberty™ SBS Self-Adhering Base/Ply Sheet ASTM D4601 II N/A GA ,IN APP, Smooth- Surface Membranes Ruberoid® Torch Smooth ASTM D6222 I S GA, IN Tri-Ply® APP Smooth Membrane ASTM D6222 I S GA, IN APP, Granule Surfaced Membranes Ruberoid® Torch Granule ASTM D6222 I G GA, IN Tri-Ply® APP Granule Membrane ASTM D6222 I G GA, IN Ruberoid® Torch Plus Granule FR ASTM D6222 II G GA Ruberoid® EnergyCap™ Torch Granule FR ASTM D6222 I G CA-S Ruberoid® EnergyCap™ Torch Plus Granule FR ASTM D6222 II G CA-S SBS, Smooth- Surface Membranes Ruberoid® 20 Smooth ASTM D6163 I S AR, CA-S, GA Ruberoid® HW 25 Smooth ASTM D6163 I S GA Ruberoid® HW Smooth ASTM D6164 I S GA Ruberoid® Mop Smooth ASTM D6164 I S CA-S, GA Ruberoid® Mop Smooth 1.5 ASTM D6164 I S CA-S, GA Ruberoid® Mop Plus Smooth ASTM D6164 II S CA-S SBS, Granule- Surface Membranes Ruberoid® 30 Granule ASTM D6163 I G GA Ruberoid® 30 Granule FR ASTM D6163 I G GA Ruberoid® EnergyCap™ 30 Granule FR ASTM D6163 I G CA-S, GA Liberty™ SBS Self-Adhering Cap Sheet ASTM D6164 I G AR, GA, IN Ruberoid® Mop Granule FR ASTM D6164 I G GA Ruberoid® Mop Granule ASTM D6164 I G GA Intec Flex PRF ASTM D6164 I G GA Tri-Ply® SBS Granule Cap Sheet ASTM D6164 I G GA NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R30 GAF Modified Bitumen Roof Systems Revision 30: 03/08/2021 Page 5 of 6 TABLE 1 (CONTINUED): EVALUATED MEMBRANES Type Product Material Standard Plant(s) Reference Type Grade SBS, Granule- Surface Membranes Ruberoid® HW Granule ASTM D6164 I G GA Ruberoid® HW Granule FR ASTM D6164 I G GA Ruberoid® Mop Plus Granule FR ASTM D6164 II G GA Ruberoid® Mop Plus Granule ASTM D6164 II G GA Ruberoid® EnergyCap™ Mop Plus Granule FR ASTM D6164 II G CA-S Ruberoid® HW Plus Granule ASTM D6164 II G GA Ruberoid® HW Plus Granule FR ASTM D6164 II G GA Ruberoid® EnergyCap™ HW Plus Granule FR ASTM D6164 II G CA-S 5. LIMITATIONS: 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classificat ion. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low-slope roofs. 5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.6.2 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. 5.7.1 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5680-R30 GAF Modified Bitumen Roof Systems Revision 30: 03/08/2021 Page 6 of 6 5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: GAF Modified Bitumen Roof Systems shall be installed in accordance with GAF published installation instructions, subject to the Limitations / Conditions of Use noted herein. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL, LLC – QUA9625: (414) 248-6409, karen.buchmann@ul.com - THE 101-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 1 of 101 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6 1B Wood New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-10 1C Wood New, Reroof (Tear-Off), Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-13 1D Wood New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 14 1E Wood New, Reroof (Tear-Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 14-15 1F Wood New, Reroof (Tear-Off), Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16 1G Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-17 1H Wood New, Reroof (Tear-Off), Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 18 1I Wood New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18 2A Steel or Structural concrete New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-28 2B Steel or Structural concrete New, Reroof (Tear-Off), Recover B-2 Mech. Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 29-32 2C Steel or Structural concrete New, Reroof (Tear-Off), Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 33-40 2D Steel or Structural concrete New, Reroof (Tear-Off), Recover C-1A Thermal Barrier with Vapor Barrier, Mech. Attached Insulation, Bonded Roof Cover 41 2E Steel or Structural concrete New, Reroof (Tear-Off), Recover C-3 Bonded and Mech. Attached Insulation, Bonded Roof Cover 41 2F Steel or Structural concrete New, Reroof (Tear-Off), Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 42-45 3A Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 46-48 3B Structural concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 48-58 3C Structural concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 59 4A Lightweight concrete New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 60-62 4B Lightweight concrete New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 63 4C Lightweight concrete New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 64-67 4D Lightweight concrete New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 67 5A Cementitious wood fiber New, Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 68 5B Cementitious wood fiber New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 68-69 5C Cementitious wood fiber New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 70 6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 71 6B Gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 71-72 6C Gypsum Reroof (Tear-Off) C-1 Mech. Attached Insulation, Bonded Roof Cover 72 6D Gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 72-73 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base Insulation Layer Only) 74-83 7B Various Recover A-1 Bonded Insulation, Bonded Roof Cover (Base and Top Insulation Layers) 84-101 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S, Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate, Drill-Tec #12 DP Fastener or Drill-Tec #14 HD Fastener with Drill-Tec 3” Flat Steel Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3” Recessed Steel Plate, Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 2 of 101 ➢ Steel Deck: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only); Drill-Tec ASAP 3S; Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate; Drill-Tec Extra Heavy Duty ASAP Roofing Fastener - Insulation, Drill-Tec #12 DP Fastener, Drill-Tec #14 HD Fastener or Drill-Tec #15 EHD Fastener with Drill-Tec 3” Flat Steel Plate, Drill-Tec #12 DPH Fastener with Drill-Tec 3” Recessed Steel Plate, Drill-Tec 3” ASAP Flat or Drill-Tec 3” ASAP Recessed. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate, Drill-Tec #14 HD Fastener with Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” ASAP Flat (#14 only). Minimum 1- inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for, or installed below, rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. ➢ Hot asphalt: Full Coverage at 25-30 lbs/square. If applying to concrete deck; deck shall be primed with ASTM D41 primer. ➢ GAF 2-Part Roofing Adhesive (G-2-Part): Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c. ➢ GAF LRF Adhesive M (LRF-M): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ GAF LRF Adhesive XF (LRF-XF): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ H.B. Fuller Millennium One-Step Foamable Adhesive (M-OSFA): Continuous 1-inch wide ribbons, 12-inch o.c. ➢ OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. using OMG PaceCart, SpotShot or Canister delivery methods. Note: OlyBond Classic may be used where OlyBond 500 is referenced ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. ➢ Hot asphalt: MDP = -240.0 psf (Min. 0.5-inch thick) ➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP = -117.5 psf (Min. 1.0-inch thick) ➢ GAF LRF Adhesive M (LRF-M): MDP = -232.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation) ➢ H.B. Fuller Millennium One-Step Foamable Adhesive (M-OSFA): MDP = -157.5 psf (Min. 0.5-inch thick polyisocyanurate) ➢ GAF LRF Adhesive XF (LRF-XF) or OlyBond 500 (OB500): MDP = -292.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation) ➢ OlyBond 500 (OB500): MDP = -315.0 psf (Min. 0.5-inch thick EnergyGuard RH or RN) ➢ GAF LRF Adhesive XF (LRF-XF) or OlyBond 500 (OB500): MDP = -487.5 psf (Min. 0.5-inch thick EnergyGuard RA) 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 3 of 101 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP-AA (Base/ Ply sheets, Asphalt-Applied) Base Ply: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet Hot asphalt at 25 lbs/square. Ply: One or more plies GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M BP-CA (Base/ Ply sheets, Cold-Applied) Base Ply: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Matrix 102 SBS Membrane Adhesive at 1.5 gal/sq. SBS-AA (SBS, Asphalt-Applied) Base Ply or Ply: One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth Hot asphalt at 25 lbs/square. Cap Ply: Ruberoid 30 Granule, Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberoid Mop Plus Smooth, Ruberoid Mop Granule FR, Ruberoid Mop Granule, Tri-Ply SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid Mop Plus Granule FR, Ruberoid Mop Plus Granule, Ruberoid EnergyCap Mop Plus Granule FR SBS-CA (SBS, Cold-Applied) Base Ply or Ply: Ruberoid 20 Smooth Matrix 102 SBS Membrane Adhesive at 1.5 gal/sq. Cap Ply: Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop Plus Granule FR SBS-CA1 (SBS, Cold-Applied) Base Ply: Ruberoid 20 Smooth or Ruberoid Mop Smooth 1.5 Matrix 101 Premium SBS Membrane Adhesive at 1.5 – 2.0 gal/square Cap Ply: Ruberoid 30 Granule FR, Ruberoid EnergyCap 30 Granule FR, Ruberoid Mop Plus Granule FR, Ruberoid EnergyCap Mop Plus Granule FR SBS-TA (SBS, Torch-Applied) Base Ply or Ply: One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Torch applied Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid EnergyCap HW Plus Granule FR APP-TA (APP, Torch-Applied) Base Ply or Ply: One or two plies Ruberoid Torch Smooth, Tri-Ply APP Smooth Membrane Cap Ply: Ruberoid Torch Granule, Tri-Ply APP Granule Membrane, Ruberoid Torch Plus Granule FR, Ruberoid EnergyCap Torch Granule FR, Ruberoid EnergyCap Torch Plus Granule FR NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 4 of 101 MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-SA (self-adhering) Base Ply or Ply: Liberty SBS Self-Adhering Base/Ply Sheet Self-adhered Cap Ply Liberty SBS Self-Adhering Cap Sheet Note: Systems with a smooth-surfaced cap ply shall be surfaced in accordance with GAF requirements, meeting the fire resistance requirements of FBC Section 1505. Refer to FBC Section 1504.8 for limitations in the use of aggregate surfacing. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A: OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE APPLICATION C-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied Hot asphalt -360.0 C-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied GAF 2-Part, 12-inch o.c. -169.0 C-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied GAF 2-Part, 12-inch o.c. -180.0 C-VB-4. GAF SA Primer GAF SA Vapor Retarder Self-adhering GAF 2-Part, 12-inch o.c. -202.5 C-VB-5. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering GAF 2-Part, 12-inch o.c. -250.0 C-VB-6. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied GAF 2-Part, 12-inch o.c. -262.5 C-VB-7. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied GAF 2-Part, 12-inch o.c. -270.0 C-VB-8. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-M, 12-inch o.c. -180.0 C-VB-9. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-M, 12-inch o.c. -202.5 C-VB-10. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied LRF-M, 12-inch o.c. -495.0 C-VB-11. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied LRF-XF, 12-inch o.c. -169.0 C-VB-12. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth Torch-applied LRF-XF, 12-inch o.c. -180.0 C-VB-13. GAF SA Primer GAF SA Vapor Retarder Self-adhering LRF-XF, 12-inch o.c. -202.5 C-VB-14. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering LRF-XF, 12-inch o.c. -250.0 C-VB-15. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied LRF-XF, 12-inch o.c. -262.5 C-VB-16. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 30 Hot asphalt applied LRF-XF, 12-inch o.c. -270.0 C-VB-17. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Smooth Torch-applied OlyBond 500, 12-inch o.c. -165.0 C-VB-18. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW 25 Smooth Torch-applied OlyBond 500, 12-inch o.c. -180.0 C-VB-19. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Liberty SBS Self-Adhering Cap Sheet Self-adhering OlyBond 500, 12-inch o.c. -187.5 C-VB-20. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth Matrix 102 SBS Membrane Adhesive at 1.5 gal/square OlyBond 500, 12-inch o.c. -202.5 C-VB-21. GAF SA Primer GAF SA Vapor Retarder Self-adhering OlyBond 500, 12-inch o.c. -202.5 C-VB-22. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch Granule Torch-applied OlyBond 500, 12-inch o.c. -225.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 5 of 101 VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A: OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE APPLICATION C-VB-23. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid HW Smooth Torch-applied OlyBond 500, 12-inch o.c. -232.5 C-VB-24. Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet or GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Hot asphalt applied OlyBond 500, 12-inch o.c. -352.5 16A Vapor barrier options for over structural concrete deck followed by cellular lightweight insulating concrete carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Tables 4A through 4D applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK FOLLOWED BY CELLULAR LIGHTWEIGHT INSULATING CONCRETE PER TABLES 4A THROUGH 4D: OPTION # PRIMER VAPOR BARRIER LIGHTWEIGHT CONCRETE MDP (PSF) TYPE ATTACH LWC-VB-1. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 200 psi Mearlcrete (FL13492) -82.5 LWC-VB-2. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 300 psi Celcore Cellular Concrete (FL2037) -135.0 LWC-VB-3. Matrix 307 Premium Asphalt Primer or ASTM D41 primer Base Ply (Optional): One or two plies Ruberoid HW 25 Smooth, Ruberoid HW Smooth Cap Ply: Ruberoid HW Granule, Ruberoid HW Granule FR, Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR Torch- applied Min. 300 psi Elastizell (FL4994) -302.5 17 Fire barriers of FireOut™ Fire Barrier Coating, VersaShield Solo™ Fire-Resistant Slip Sheet are optional in all assemblies when overlying components are mechanically fastened. 18 The following insulations are interchangeable within the scope of this Evaluation Report: ACCEPTABLE ALTERNATES (INSULATION) Listed Product Alternate EnergyGuard Polyiso Insulation EnergyGuard NH Polyiso Insulation EnergyGuard Ultra Polyiso Insulation EnergyGuard NH Ultra Polyiso Insulation EnergyGuard HD Polyiso Insulation EnergyGuard NH HD Polyiso Insulation EnergyGuard HD Plus Polyiso Insulation EnergyGuard NH HD Plus Polyiso Insulation 19 For System Types B-1, B-2, C-1, C-2, D-1 or Type D-2, GAF SA Vapor Retarder may be installed atop the roof deck prior to installation of the insulation and roof cover. Refer to FM Loss Prevention Data Sheet 1-29 (February 2020) for design and installation limitations. 20 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 6 of 101 TABLE 1A: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-1. Min. 19/32-inch plywood or OSB; 2 ft span Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 W-2. Min. 19/32-inch plywood or OSB; 2 ft span Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 W-3. Min. 19/32-inch plywood or OSB; 2 ft span Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-4. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 W-5. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 7 of 101 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-6. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 W-7. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -45.0 W-8. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at the 4-inch lap and 6- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 W-9. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at the 4-inch lap and 6- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 8 of 101 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-10. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 W-11. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -52.5 W-12. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -60.0 W-13. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS- AA, SBS-TA, APP-TA -60.0 SELF-ADHERING BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 9 of 101 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-14. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 2-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA or APP-TA SBS-SA, SBS-TA or APP- TA -45.0 VENTING SYSTEMS: W-15. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -45.0 W-16. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -45.0 W-17. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 4-inch laps and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -52.5 W-18. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1- 5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at the 4-inch lap and 8- inch o.c. in two staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 10 of 101 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-19. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1- 5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at the min. 4-inch lap and 9-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -60.0 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-20. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-21. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 11 of 101 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-22. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 W-23. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 W-24. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-25. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 12 of 101 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-26. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 2-inch lap and 12-inch o.c. in three, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-27. Min. 19/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at the min. 2-inch lap and 12-inch o.c. in three, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-28. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec 3” Ribbed Galvalume Plate (Flat) with Drill- Tec #14 Fasteners or Drill-Tec #14 HD Fastener with Drill- Tec 3” Flat Steel Plate 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Insulation Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA SBS-AA -67.5* W-29. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8- inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or Min. 0.75- inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 13 of 101 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-30. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8- inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso or min. 1.5- inch EnergyGuard RA or EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -82.5 VENTING SYSTEMS: W-31. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at the min. 4-inch lap and 16-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS- AA SBS-AA, SBS-TA, APP-TA -52.5 W-32. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at the min. 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS- AA SBS-AA, SBS-TA, APP-TA -60.0 W-33. Min. 15/32- inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at the 4-inch lap and 8- inch o.c. in three staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS- AA SBS-AA, SBS-TA, APP-TA -82.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 14 of 101 TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-34. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation Drill-Tec #12 Fastener with Drill-Tec 3” Steel Plate 1 per 1.8 ft2 Optional additional layer(s), min. 1.5- inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -52.5 W-35. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch EnergyGuard RN Drill-Tec #12 Fastener with Drill-Tec AccuTrac Flat Plate or AccuTrac Recessed Plate 1 per 1.8 ft2 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -52.5 TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-36. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 0.75-inch, one or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Composite or EnergyGuard RA Composite Note 2 1 per 3.0 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-37. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 0.75-inch, one or more layers, any combination, loose laid Min. 1-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Note 2 1 per 2.0 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 W-38. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 only) 1 per 1.8 ft2 BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 SELF-ADHERING BASE PLY: W-39. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 (#14 Fasteners only) 1 per 2.0 ft2 SBS-SA (Optional) SBS- SA SBS-SA -45.0 W-40. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec #12 Fasteners and Drill-Tec 3” Steel Plates 1 per 1.8 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -52.5 W-41. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec #12 Fasteners and Drill-Tec 3” Steel Plates 1 per 1.6 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 15 of 101 TABLE 1E: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply VENTING SYSTEMS: W-42. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.3 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0* COLD-APPLIED SYSTEMS: W-43. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 fasteners only) 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0* W-44. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 fasteners only) 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -60.0 W-45. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board Note 2 (#14 fasteners only) 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -82.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 16 of 101 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: W-46. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-47. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -60.0 W-48. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Prelim attach GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 8-inch o.c. at min. 2-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -75.0 SELF-ADHERING BASE PLY: W-49. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span Min. 1-inch, one or more layers, any combination Loose laid Liberty SBS Mechanically Attached Base Sheet Note 2 8-inch o.c. at min. 3-inch laps and 8-inch o.c. at two, equally spaced, staggered center rows SBS-SA None SBS-SA -97.5 TABLE 1G: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: W-50. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8- inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -45.0 W-51. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 12 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. at two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -45.0 W-52. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 12- inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-53. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 4-inch laps and 6- inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 17 of 101 TABLE 1G: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply W-54. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA, SBS-CA, APP-TA -52.5 W-55. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. in two, equally spaced, staggered center rows (Optional) APP- TA APP-TA -60.0 W-56. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 12 ga. annular ring shank nails 8-inch o.c. at min. 4-inch laps and 8- inch o.c. at three, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA SBS-AA -75.0 W-57. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Eliminator Nailable Venting Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA, SBS-CA, APP-TA -82.5 W-58. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at min. 2-inch laps and 4- inch o.c. in four (4), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -97.5 W-59. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 3-inch o.c. at min. 3-inch laps and 3- inch o.c. at five (5), equally spaced, staggered center rows. Base sheet and tin-caps shall be primed with Matrix 307 Premium Asphalt Primer prior to base ply installation (Optional) SBS- TA Ruberoid HW Plus Granule, Ruberoid HW Plus Granule FR, Ruberoid EnergyCap HW Plus Granule FR -120.0 SELF-ADHERING BASE PLY: W-60. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span Liberty SBS Mechanically Attached Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at min. 4-inch laps and 9- inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- SA SBS-SA, SBS-TA or APP-TA -37.5 W-61. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span Liberty SBS Mechanically Attached Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 3-inch laps and 8- inch o.c. in three, equally spaced, staggered center rows (Optional) SBS- SA SBS-SA, SBS-TA or APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 18 of 101 TABLE 1H: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY FASTEDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: W-62. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at 2-inch laps and 12- inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -45.0 W-63. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 16-inch o.c. at 4-inch laps and 16- inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA SBS-AA -52.5 W-64. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 12-inch o.c. at 4-inch laps and 12- inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA SBS-AA -60.0 W-65. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 12-inch o.c. at 2-inch laps and 12- inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -60.0 W-66. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #80 Ultima Base Sheet, Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 Note 2 9-inch o.c. at 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-TA SBS-TA (polyester only) -60.0 W-67. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 (#14 ONLY) 8-inch o.c. at 4-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA SBS-AA -97.5 W-68. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Note 2 8-inch o.c. at 2-inch laps and 8-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA, SBS-TA, SBS-CA, APP-TA -105.0 SELF-ADHERING BASE PLY: W-69. Min. 19/32-inch plywood or 1-inch wood plank; 2 ft span StormSafe Anchor Sheet Note 2 (Drill-Tec AccuTrac Flat Plate, Drill-Tec 3” Flat Steel Plate or Drill-Tec 3” Recessed Steel Plate only) 9-inch o.c. at 4-inch laps and 9-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA Note: Seams sealed with TOPCOAT SB900 or Flexseal -60.0 W-70. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span Liberty SBS Mechanically Attached Base Sheet Note 2 (HD Fasteners only) 8-inch o.c. at 3-inch laps and 8-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA, SBS-TA or APP- TA -60.0 TABLE 1I: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Cap Ply W-71. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span, 8d rink shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square None SBS-SA -75.0 W-72. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span, #8 x 2½” deck screws, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square None SBS-SA -90.0 W-73. Min. 15/32-inch plywood or 1-inch wood plank; 2 ft span, 8d rink shank nails, 6” o.c. Matrix 307 Premium Asphalt Primer at 1.0 gal/square SBS-SA SBS-SA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 19 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: SC-1 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) One or more BP-AA, SBS- AA SBS-AA -37.5* SC-2 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.625-inch DensDeck Prime Note 2 1 per 4.0 ft2 Min. 1.5-inch EnergyGuard followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -45.0* SC-3 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.5-inch DensDeck Prime Note 2 1 per 2.7 ft2 Min. 1.5-inch EnergyGuard followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -45.0* SC-4 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.7 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* SC-5 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* SC-6 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* SC-7 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA -60.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 20 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-8 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0* SC-9 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.5 ft2 Min. 1.0-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA or SBS-TA -60.0 SC-10 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.3 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA SBS-AA, SBS-TA -60.0 SC-11 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.5 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA or SBS-TA -67.5 SC-12 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-13 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 21 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-14 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt, GAF 2-Part or OB500 BP-AA, SBS- AA None SBS-CA -45.0* SC-15 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-16 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -52.5 SC-17 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 SC-18 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-19 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-20 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-21 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 22 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-22 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 SELF-ADHERING BASE PLY: SC-23 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-EnergyGuard RH, EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-24 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-EnergyGuard RH, EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* SC-25 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Additional layer(s), min. 0.5-inch thick base insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-26 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Additional layer(s), min. 0.5-inch thick base insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-27 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Additional layer(s), min. 1.5-inch thick base insulation OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-28 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-29 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 23 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-30 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-31 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-32 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-33 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-34 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA SBS-TA -52.5 SC-35 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS-TA SBS-TA -60.0 SC-36 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-37 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 24 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-38 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-39 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-40 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt, GAF 2-Part SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-41 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Additional layer(s), min. 0.5-inch thick base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-42 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Additional layer(s), min. 0.5-inch thick base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-43 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Additional layer(s), min. 1.5-inch thick base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-44 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-45 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 25 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-46 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-47 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-48 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-49 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-50 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA SBS-TA -52.5 SC-51 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 1.6 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 VENTING SYSTEMS: SC-52 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 Additional layer(s) of base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -45.0* COLD-APPLIED SYSTEMS: SC-53 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 26 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-54 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH Note 2 1 per 2.9 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500, LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -37.5* SC-55 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -45.0* SC-56 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -45.0* SC-57 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -52.5 SC-58 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -45.0* SC-59 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -45.0* SC-60 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -52.5 HYBRID HOT/COLD-APPLIED SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 27 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-61 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-62 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.7 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-63 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 3.2 ft2 Optional additional layers base insulation followed by min.0.5-inch EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-64 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 4.0 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-65 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 3.2 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-66 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-67 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -60.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 28 of 101 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-68 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.3 ft2 Optional additional layers base insulation followed by min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -60.0 SC-69 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-70 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 0.5-inch thick base insulation followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-71 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -52.5 SC-72 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 2.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-73 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH Note 2 1 per 4.0 ft2 Optional additional layer(s) min. 1.5-inch thick base insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-74 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard Ultra Note 2 1 per 1.8 ft2 Optional additional layer(s) min. 1.5-inch thick EnergyGuard Polyiso Insulation or EnergyGuard Ultra Polyiso Insulation followed by Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 29 of 101 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap CONVENTIONAL SYSTEMS: SC-75 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -45.0* SC-76 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -45.0* SC-77 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -45.0* SC-78 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -45.0* SC-79 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 SC-80 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA -67.5 SELF-ADHERING BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 30 of 101 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-81 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA None SBS-SA -45.0* SC-82 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-83 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA None SBS-SA -45.0* SC-84 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN followed by min. 0.25- inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-85 Min. 22 ga., Type B, Grade 33 steel Min. 0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-86 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation LRF-M or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* SC-87 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 31 of 101 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-88 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -67.5 VENTING SYSTEMS: SC-89 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -45.0* SC-90 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -45.0* SC-91 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS- AA SBS-AA -67.5 COLD-APPLIED SYSTEMS: SC-92 Min. 22 ga., Type B, Grade 33 steel Min.0.5-inch SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.7 ft2 Liberty SBS Self-Adhering Cap Sheet Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -45.0* SC-93 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation LRF-M or OB500 SBS-CA1 None SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 32 of 101 TABLE 2B: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Thermal Barrier Temp Roof Insulation Layer(s) Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Cap SC-94 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-CA1 None SBS-CA1 -45.0* SC-95 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation GAF 2-Part, LRF-M, LRF- XF or OB500 SBS-CA1 None SBS-CA1 -67.5 HYBRID HOT/COLD APPLIED SYSTEMS: SC-96 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard RN Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-97 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 4.0 ft2 Primer: GAF SA Primer or Matrix 307 Premium Asphalt Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -45.0* SC-98 Min. 22 ga., Type B, Grade 33 steel 0.5-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) 1 per 2.0 ft2 Primer: GAF SA Primer Vapor Retarder: GAF SA Vapor Retarder, self- adhering One or more layers, base layer min. 1-inch thick, optional subsequent layer(s) min. 1.5- inch thick EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, LRF-M, LRF- XF or OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 33 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: SC-99 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -30.0* SC-100 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -37.5* SC-101 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.625-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-102 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.13 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-103 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-104 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Note 2 1 per 4.0 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA, SBS-TA, APP-TA -45.0* SC-105 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or Structodek High Density Fiberboard Roof Insulation Note 2 1 per 2.0 ft2 SBS-AA (Optional) SBS-AA SBS-AA, SBS-TA -45.0* SC-106 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* SC-107 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -45.0* SC-108 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 SBS-AA, SBS-TA, APP- TA (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 SC-109 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime Note 2 1 per 1.5 ft2 SBS-AA, SBS-TA, APP- TA (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 34 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-110 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.8 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -52.5 SC-111 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.8 ft2 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 SC-112 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-113 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -60.0 SC-114 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 1.0 ft2 SBS-AA (Optional) SBS-AA or SBS-TA SBS-AA, SBS-TA -67.5 SC-115 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime Note 2 1 per 1.5 ft2 SBS-TA (Optional) SBS-TA SBS-TA -67.5 SC-116 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -67.5 SC-117 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.5 ft2 SBS-TA (Optional) SBS-TA SBS-TA -75.0 SC-118 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -82.5 SC-119 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 35 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-120 Min. 20 ga., type B, Grade 33 steel or min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 1 per 1.0 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -90.0 SC-121 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.0 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -97.5 SC-122 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.5 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA SBS-AA, SBS-TA -97.5 SC-123 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 (#14 only) 1 per 1.0 ft2 SBS-TA, APP-TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -105.0 SC-124 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.0 ft2 APP-TA (Optional) APP-TA APP-TA -105.0 SC-125 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.0 ft2 SBS-TA (Optional) SBS-TA SBS-TA -120.0 SC-126 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime Note 2 1 per 1.0 ft2 SBS-TA (Optional) SBS-TA SBS-TA -127.5 SELF-ADHERING BASE PLY: SC-127 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, SBS-TA, APP-TA -30.0* SC-128 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 4.0 ft2 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, SBS-TA, APP-TA -37.5* SC-129 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 4.0 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -37.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 36 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-130 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.7 ft2 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, SBS-TA, APP-TA -45.0* SC-131 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -45.0* SC-132 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-133 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-134 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-135 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 3.2 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-136 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0* SC-137 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-138 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SC-139 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA SBS-TA -60.0 SC-140 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-141 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Note 2 1 per 1.5 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 37 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-142 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -60.0 SC-143 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0 SC-144 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (#14 only) 1 per 1.8 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -60.0 SC-145 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -67.5 SC-146 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -67.5 VENTING SYSTEMS: SC-147 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 4.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -37.5* SC-148 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-149 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-150 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard RH Note 2 1 per 2.9 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-151 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Ultra Note 2 1 per 3.2 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-152 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.5-inch EnergyGuard RA Note 2 1 per 4.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA -45.0* SC-153 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 3.2 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 38 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-154 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per 3.2 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -45.0* SC-155 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per 4.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-AA -45.0* SC-156 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -52.5 SC-157 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RH Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -52.5 SC-158 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.8 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 SC-159 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Ultra Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 SC-160 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -60.0 SC-161 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.5 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -67.5 SC-162 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard RH, EnergyGuard RN Note 2 1 per 1.6 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -67.5 SC-163 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.5 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -75.0 SC-164 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2.0-inch EnergyGuard Ultra Note 2 1 per 1.5 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 39 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-165 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Note 2 1 per 1.5 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA (ASTM D6164, polyester only) -82.5 SC-166 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 3-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.6 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -82.5 SC-167 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -82.5 SC-168 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.0 ft2 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -97.5 COLD-APPLIED SYSTEMS: SC-169 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 2.0 ft2 BP-CA None SBS-CA -45.0* SC-170 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 SBS-CA None SBS-CA -45.0* SC-171 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0* SC-172 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation Note 2 1 per 2.9 ft2 SBS-CA1 None SBS-CA1 -45.0* SC-173 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 SBS-CA1 None SBS-CA1 -45.0* SC-174 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1.5-inch Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -45.0* SC-175 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (AccuTrac Flat Plates only) 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 40 of 101 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply SC-176 Min. 22 ga., type B, Grade 50 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard Polyiso Insulation Note 2 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -60.0 SC-177 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -67.5 SC-178 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Note 2 1 per 1.8 ft2 SBS-CA1 None SBS-CA1 -67.5 SC-179 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.3 ft2 SBS-CA1 None SBS-CA1 -67.5 HYBRID HOT/COLD-APPLIED SYSTEMS: SC-180 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 4.0 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -45.0* SC-181 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Note 2 (AccuTrac Flat Plates) 1 per 1.3 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -52.5 SC-182 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -60.0 SC-183 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -82.5 SC-184 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -90.0 SC-185 Min. 20 ga., type B, Grade 33 steel, min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.5 ft2 BP-AA or SBS-AA (Optional) BP- AA or SBS-AA SBS-CA1 -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 41 of 101 TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SELF-ADHERING BASE PLY: SC-186 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.625-inch DensDeck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with GAF SA Vapor Retarder, self-adhered Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -45.0* COLD-APPLIED BASE PLY: SC-187 Min. 22 ga., Type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 0.625-inch DensDeck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with GAF SA Vapor Retarder, self-adhered Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Note 2 1 per 2.0 ft2 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -45.0* TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-3: BONDED AND MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Adhesive & Fasteners (Notes 6,7,8,11) Attach Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: SC-188 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: OB500 Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 SC-189 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: LRF-XF Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 SELF-ADHERING BASE PLY: SC-190 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: OB500 Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 SC-191 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra, loose-laid Min. 0.25-inch DensDeck Prime Adhesive: LRF-XF Fasteners: Drill-Tec XHD (steel only) or Drill- Tec #14 HD (concrete only) & Drill-Tec Plates Adhesive: 12-inch o.c. Fasteners: 1 per 1.3 ft2 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 42 of 101 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply CONVENTIONAL SYSTEMS: SC-192 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 24-inch o.c. at min. 2-inch laps and 24-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -30.0* SC-193 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 18-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -37.5* SC-194 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 18-inch o.c. at min. 2-inch laps and 18-inch o.c. in three, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -45.0* SC-195 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 12-inch o.c. at min. 2-inch laps and 18-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP- TA SBS-TA, APP-TA -45.0* SC-196 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 12-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-AA SBS-AA, SBS-TA -45.0* SC-197 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation. Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth Note 2 18-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -45.0* SC-198 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3.5-inch laps BP-AA, SBS- AA SBS-AA -45.0* SC-199 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 Off-centered in the lap by 0.5-inch towards the sheet-edge and spaced 18-inch o.c. within the min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* SC-200 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill- Tec #12 (steel only) or #14 18-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 43 of 101 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply SC-201 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid HW Smooth Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 12-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -45.0* SC-202 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth Note 2 12-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -52.5 SC-203 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2 in. Barbed Plates with Drill-Tec #12 (steel only) or #14 Off-centered in the lap by 0.5-inch towards the sheet-edge and spaced 12-inch o.c. within the min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -52.5 SC-204 Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec 2-3/8 in. Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plates with Drill-Tec XHD Off-centered in the lap by 0.25- inch towards the sheet-edge and spaced 12-inch o.c. within the min. 5-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -67.5 SC-205 Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec Batten Bar with Drill- Tec XHD 12-inch o.c. within min. 4-inch wide, heat-welded laps (Optional) SBS-TA SBS-TA -67.5 SC-206 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-AA SBS-AA, SBS-TA -82.5 SC-207 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP- TA SBS-TA, APP-TA -82.5 SC-208 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Note 2 (Drill-Tec 3” Standard Steel Plate; Drill-Tec ASAP 3S (steel) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate only) 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-TA, APP- TA SBS-TA, APP-TA -82.5 SC-209 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3.25-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS- AA SBS-AA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 44 of 101 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply SC-210 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Optional BP-AA or SBS-AA vapor barrier over concrete deck. One or more layers, any combination insulation Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5, Ruberiod Mop Plus Smooth Note 2 6-inch o.c. at min. 3.5-inch laps (Optional) SBS-TA SBS-TA -112.5 SC-211 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-TA SBS-TA -150.0 SC-212 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Drill-Tec #14 Fasteners with Drill-Tec 2 3/8 in. Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plates 6-inch o.c. at min. 3.25-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows SBS-TA SBS-TA -150.0 SC-213 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Note 2 (Drill-Tec 3” Standard Steel Plate; Drill-Tec ASAP 3S (steel) or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with a 3” Metal Plate only) 6-inch o.c. at min. 3.5-inch laps and 6-inch o.c. in three, equally spaced, staggered center rows (Optional) Ruberoid HW Smooth SBS-TA -150.0 SELF-ADHERING BASE PLY: SC-214 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Mechanically Attached Base Sheet Note 2 12-inch o.c. at min. 3.5-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA, SBS- SA-T, SBS-TA or APP-TA SBS-SA, SBS-TA or APP-TA -30.0* SC-215 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Mechanically Attached Base Sheet Note 2 9-inch o.c. at min. 4-inch laps and 9-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -37.5 SC-216 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Liberty SBS Self-Adhering Base/Ply Sheet Note 2 12-inch o.c. at min. 3.5-inch laps and 18-inch o.c. in one center row (Optional) SBS-SA SBS-SA -45.0* COLD-APPLIED SYSTEMS: SC-217 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 18-inch o.c. at min. 3-inch laps None SBS-CA or SBS-CA1 -30.0* SC-218 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid 20 Smooth Note 2 12-inch o.c. at min. 3-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows None SBS-CA or SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 45 of 101 TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Cap Ply SC-219 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Note 2 12-inch o.c. at min. 2-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows None SBS-CA -45.0* SC-220 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination Ruberoid Mop Smooth 1.5 Note 2 24-inch o.c. at min. 3-inch laps and 24-inch o.c. in two, equally spaced, staggered center rows None SBS-CA or SBS-CA1 -45.0 SC-221 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete One or more layers, any combination GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Note 2 6-inch o.c. at min. 3.5-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows SBS-CA at 2.0 gal/sq. SBS-CA at 2.0 gal/sq. -82.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 46 of 101 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY C-1. Primed structural concrete Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -140.0 C-2. Primed structural concrete Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-3. Primed structural concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-4. Primed structural concrete Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA SBS-AA, SBS-TA or APP-TA -270.0 C-5. Structural concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-6. Structural concrete Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-TA (Optional) One or more SBS- TA SBS-TA -245.0 C-7. Structural concrete Min. 0.25-inch DensDeck Prime LRF-XF SBS-TA (Optional) One or more SBS- TA SBS-TA -300.0 C-8. Structural concrete Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 C-9. Structural concrete Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) One or more SBS- TA SBS-TA -300.0 SELF-ADHERING BASE PLY WITH BASE INSULATION LAYER ONLY C-10. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP- TA -90.0 C-11. Primed structural concrete Min. 1.5-inch EnergyGuard RN Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 C-12. Primed structural concrete Min. 1.5-inch EnergyGuard RA Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-13. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5 C-14. Structural concrete Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -167.5 C-15. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -180.0 C-16. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -180.0 C-17. Structural concrete Min. 1.5-inch EnergyGuard RN GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 47 of 101 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-18. Structural concrete Min. 1.5-inch EnergyGuard RA GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-19. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-20. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5 C-21. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -180.0 C-22. Structural concrete Min. 0.5-inch EnergyGuard Ultra LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-23. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -285.0 C-24. Structural concrete Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 C-25. Structural concrete Min 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0 C-26. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 C-27. Structural concrete Min. 0.25-inch DensDeck OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -122.5 C-28. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -137.5 C-29. Structural concrete Min. 1-inch EnergyGuard RN OB 500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -162.5 C-30. Structural concrete Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -167.5 C-31. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 C-32. Structural concrete Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -285.0 VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY C-33. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -150.0 C-34. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-TA or APP-TA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 48 of 101 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-35. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -150.0 C-36. Primed structural concrete Min. 0.5-inch EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet SBS-AA SBS-AA -172.5 C-37. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -172.5 C-38. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-TA or APP-TA -172.5 C-39. Primed structural concrete Min. 1-inch EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS-AA SBS-AA -292.5 COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY C-40. Structural concrete Min. 1.5-inch EnergyGuard RA or EnergyGuard RH LRF-XF SBS-CA1 None SBS-CA1 -60.0 C-41. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 SBS-CA1 None SBS-CA1 -60.0 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-42. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA (Optional) BP-AA SBS-AA or SBS-TA -112.5 C-43. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck Prime Hot asphalt APP-TA (Optional) APP-TA APP-TA -127.5 C-44. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, EnergyGuard Perlite Recover Board, min. 0.75-inch EnergyGuard Perlite Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 49 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-45. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -172.5 C-46. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -187.5 C-47. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-48. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA (Optional) SBS-TA SBS-TA -232.5 C-49. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -240.0 C-50. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 C-51. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA SBS-AA, SBS- TA -255.0 C-52. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA SBS-AA, SBS- TA or APP-TA -270.0 C-53. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -307.5 C-54. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 50 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-55. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 C-56. Structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-57. Structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -232.5 C-58. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck or DensDeck Prime GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 C-59. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 C-60. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 C-61. Structural concrete Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, primed with Matrix 307 Premium Asphalt Primer LRF-XF SBS-TA (Optional) SBS-TA SBS-TA -210.0 C-62. Structural concrete Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-63. Structural concrete Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -232.5 C-64. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 C-65. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -240.0 C-66. Structural concrete Min. 1.5-inch EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-TA (Optional) SBS-TA SBS-TA -300.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 51 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-67. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -150.0 C-68. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -165.0 C-69. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 C-70. Structural concrete Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, primed with Matrix 307 Premium Asphalt Primer OB500 SBS-TA (Optional) SBS-TA SBS-TA -210.0 C-71. Structural concrete Min. 2.0-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 C-72. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -240.0 C-73. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) SBS-TA SBS-TA -300.0 SELF-ADHERING BASE PLY WITH POLYISOCYANURATE BASE INSULATION LAYER C-74. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-75. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -180.0 C-76. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) GAF 2-Part SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -180.0 C-77. Structural concrete Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 52 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-78. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) LRF-M SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-79. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M (Optional) Additional layer(s) base insulation LRF-M SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-80. Structural concrete Min. 1.5-inch EnergyGuard RH LRF-XF Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-XF SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 C-81. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-82. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-83. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-84. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-85. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -270.0 C-86. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -285.0 C-87. Structural concrete Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -97.5 C-88. Structural concrete Min. 1-inch EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -120.0 C-89. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -122.5 C-90. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-91. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -167.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 53 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-92. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (optional Matrix 307 Premium Asphalt Primer) OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-93. Structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -232.5 C-94. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -270.0 C-95. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -285.0 VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-96. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-97. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-98. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-99. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-100. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-101. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-102. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) BP-AA, SBS-AA SBS-AA -150.0 C-103. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 54 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-104. Primed structural concrete Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -172.5 C-105. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -240.0 C-106. Primed structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -240.0 C-107. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-108. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-109. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-110. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-111. Structural concrete Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -172.5 C-112. Structural concrete Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -172.5 C-113. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -180.0 C-114. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -180.0 C-115. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck or DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 55 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-116. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck or DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -240.0 C-117. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-118. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-119. Structural concrete Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -172.5 C-120. Structural concrete Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -172.5 C-121. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -180.0 C-122. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -180.0 C-123. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -240.0 C-124. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -240.0 C-125. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -90.0 C-126. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -90.0 C-127. Structural concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 56 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-128. Structural concrete Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-129. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-130. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 C-131. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS- AA SBS-AA -150.0 C-132. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP-TA -150.0 COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-133. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-CA1 None SBS-CA1 -127.5 C-134. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -172.5 C-135. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-M, M- OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -97.5 C-136. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-XF Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-XF SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -97.5 C-137. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-CA1 None SBS-CA1 -127.5 C-138. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 57 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-139. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0 C-140. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS-CA1 -97.5 C-141. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 C-142. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 HYBRID COLD/HOT-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: C-143. Primed structural concrete Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -255.0 C-144. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -180.0 C-145. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -240.0 C-146. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -180.0 C-147. Structural concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -240.0 C-148. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 C-149. Structural concrete Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 CONVENTIONAL SYSTEMS WITH POLYSTYRENE BASE INSULATION LAYER: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 58 of 101 TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP INSULATION LAYERS) SEE NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-150. Structural concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 C-151. Structural concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 C-152. Structural concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 C-153. Structural concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 C-154. Structural concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -240.0 C-155. Structural concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -240.0 C-156. Structural concrete Min. 1.0-inch Foamular 250 or 2.0-inch STYROFOAM Deckmate Plus FA OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP- TA -240.0 C-157. Structural concrete Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -277.5 SELF-ADHERING BASE PLY WITH POLYSTYRENE BASE INSULATION LAYER: C-158. Structural concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -87.5 C-159. Structural concrete Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with D41 primer GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -87.5 C-160. Structural concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -152.5 C-161. Structural concrete Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with D41 primer GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -180.0 C-162. Structural concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with D41 primer GAF 2-Part SBS-SA (Optional) SBS-SA SBS-SA -240.0 C-163. Structural concrete Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA -152.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 59 of 101 TABLE 3C: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: C-164. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer APP-TA (Optional) APP-TA APP-TA -90.0 C-165. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer None None SBS-TA -283.1 C-166. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA, SBS-AA BP-AA, SBS-AA SBS-AA -442.5 C-167. Structural concrete (Optional) Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-TA (Optional) SBS-TA SBS-TA -465.0 SELF-ADHERING BASE PLY: C-168. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -72.5 C-169. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer SBS-SA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -140.0 VENTING SYSTEMS: C-170. Structural concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA -185.0 COLD-APPLIED SYSTEMS: C-171. Structrual concrete Matrix 307 Premium Asphalt Primer or ASTM D41 primer BP-AA, BP-CA, SBS-CA (Optional) SBS-CA SBS-CA -307.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 60 of 101 TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CELCORE (FL2037): LWC-1. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-2. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-3. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-4. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-5. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -222.5 LWC-6. Structural concrete Celcore Cellular Concrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -222.5 ELASTIZELL (FL4994): LWC-7. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-8. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-9. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -222.5 LWC-10. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -222.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 61 of 101 TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-11. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-12. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-13. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-14. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-15. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -225.0 LWC-16. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -225.0 LWC-17. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 2.0-inch, min. 1.0 pcf, Insulfoam OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -120.0 LWC-18. Structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) Min. 1.0-inch Foamular 250 OB500 Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 MEARLCRETE (FL13492): LWC-19. Structural concrete Mearlcrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 62 of 101 TABLE 4A: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-20. Structural concrete Mearlcrete (min. 200 psi) (Optional) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) One or more BP-AA, SBS- AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -240.0 LWC-21. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-22. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.25 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -87.5 LWC-23. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-24. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 1.5 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 LWC-25. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -240.0 LWC-26. Structural concrete Mearlcrete (min. 200 psi) Min. 1.5-inch, min. 2.0 pcf Insulfoam GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 63 of 101 TABLE 4B: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CELCORE (FL2037): CONVENTIONAL SYSTEMS: LWC-27. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0 LWC-28. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0 VENTING SYSTEMS: LWC-29. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two equally spaced, staggered center rows Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation or EnergyGuard RH Polyiso Hot asphalt (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt GAFGLAS Stratavent Perforate d Venting Base Sheet BP-AA, SBS-AA SBS-AA, SBS-TA, APP-TA -75.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 64 of 101 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CELCORE (FL2037): CONVENTIONAL SYSTEMS: LWC-30. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two (2), equally spaced, staggered center rows SBS-TA SBS-TA -45.0 LWC-31. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat Ruberoid Mop Granule, Tri-Ply SBS Granule Cap Sheet (granules down) Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. BP-AA or SBS- AA SBS-AA, SBS-TA or APP- TA -75.0 LWC-32. Min. 22 ga. type B, Grade 33 vented steel; 5-ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 3-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. Two plies BP- AA or SBS-AA SBS-AA -75.0 HYBRID HOT/COLD-APPLIED SYSTEMS: LWC-33. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 12-inch o.c. at min. 2-inch side laps and 12-inch o.c. at three equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -45.0 LWC-34. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 9-inch o.c. at min. 2-inch side laps and 9-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -45.0 LWC-35. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7.5-inch o.c. at min. 2-inch side laps and 7.5-inch o.c. at one center row. BP-AA or SBS- AA SBS-CA1 -45.0 LWC-36. Min. 22 ga., type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 9-inch o.c. at min. 3-inch side laps and 18-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 65 of 101 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply LWC-37. Min. 22 ga., type B, Grade 33 steel; 5 ft spans or min. 2,500 psi structural concrete Celcore Cellular Concrete (min. 300 psi) with min. 1 pcf EPS board and min. 2- inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 3-inch side laps and 7-inch o.c. at two equally spaced staggered center rows. BP-AA or SBS- AA SBS-CA1 -75.0 ELASTIZELL (FL4994): LWC-38. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Elastizell Range II Lightweight Insulating Concrete (min. 200 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two (2), equally spaced, staggered center rows SBS-TA SBS-TA -45.0 MEARLCRETE (FL13492): CONVENTIONAL SYSTEMS: LWC-39. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid Mop Plus Granule (granules down) Drill-Tec Locking Impact Nail 6-inch o.c. at min. 4-inch side laps and 9-inch o.c. in two, equally spaced staggered center rows. (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -45.0 LWC-40. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 7.5-inch o.c. at min. 4-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -52.5 LWC-41. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.) 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -52.5 LWC-42. Structural concrete Mearlcrete (min. 300 psi) with optional min. 1 pcf Corrugated EPS Holey Board and min. 2-inch thick top coat GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7) 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in two, equally spaced, staggered center rows SBS-TA SBS-TA -52.5 LWC-43. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 742 psi) min. 2-inch thick top coat GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Drill-Tec Base Sheet Fastener (1.2) 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two, equally spaced staggered center rows. (Optional) BP- AA, SBS-AA SBS-AA (polyester reinforced, D6164 only) -52.5 SELF-ADHERING BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 66 of 101 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply LWC-44. Min. 22 ga. type B, Grade 33 vented steel; 6 ft spans or min. 2,500 psi structural concrete Mearlcrete (min. 300 psi) with min. 1 pcf EPS board and min. 2-inch thick top coat StormSafe Anchor Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 7.5-inch o.c. at min. 4-inch laps and 12-inch o.c. in three, equally spaced, staggered center rows (Optional) SBS-SA SBS-SA -52.5 PRE-EXISTENT CELLULAR LIGHTWEIGHT CONCRETE: CONVENTIONAL SYSTEMS: LWC-45. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid Mop Smooth Drill-Tec XHD Fasteners with Drill- Tec Eyehook AccuSeam Plates, Drill-Tec 2-3/8 in. Barbed XHD Plates, Dekfast Galvalume Steel Round 2-3/8” 20-Ga. Barbed Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 18-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -37.5 LWC-46. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid HW Smooth Drill-Tec XHD Fasteners with Drill- Tec 2-3/8 in. Barbed XHD Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 18-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -37.5 LWC-47. Min. 22 ga. type B, Grade 33 steel; 6’- 6”spans or min. 2,500 psi structural concrete Min 250-300 psi pre-existent cellular LWC with min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid Mop Smooth #14 HD Drill-Tec fasteners and 2” Drill-Tec Double-Barbed Round Steel Plates Fasten through LWC to structural deck 6-inch o.c. within 4-inch heat welded side laps (Optional) SBS-TA SBS-TA -52.5 LWC-48. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans, or min. 2,500 psi structural concrete Min. 340 psi, min. 2-inch thick pre- existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve an average withdrawal of 60 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.), Drill-Tec Locking Impact Nail, Drill-Tec DL 1.7” Base Sheet Fastener 7-inch o.c. at min. 4-inch side laps and 7-inch o.c. in two (2), equally spaced staggered center rows. SBS-AA, SBS- TA SBS-AA, SBS-TA, APP-TA -52.5 LWC-49. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid Mop Smooth Drill-Tec XHD Fasteners with Drill- Tec Eyehook AccuSeam Plates, Drill-Tec 2-3/8 in. Barbed XHD Plates, Dekfast Galvalume Steel Round 2-3/8” 20-Ga. Barbed Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 12-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -60.0 LWC-50. Min. 22 ga. type BV, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 200 psi pre-existent cellular LWC Ruberoid HW Smooth Drill-Tec XHD Fasteners with Drill- Tec 2-3/8 in. Barbed XHD Plates or Trufast 2.4” Barbed Metal Seam Plates (MCRF > 345 lbf) Fasten through LWC to structural deck 12-inch o.c. within 5-inch wide, torched or heat-welded side laps (Optional) SBS-TA SBS-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 67 of 101 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply LWC-51. Min. 22 ga. type B, Grade 33 steel; 6 ft spans or min. 2,500 psi structural concrete Min 250-300 psi pre-existent cellular LWC with min. 1 pcf EPS board and min. 2-inch thick top coat GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M Note 2 Fasten through LWC to structural deck 12-inch o.c. at 4-inch side laps and 12-inch o.c. in two, equally spaced staggered center rows. (Optional) BP- AA, SBS-AA SBS-AA, SBS-TA -67.5 LWC-52. Min. 22 ga., type BV, Grade 40 steel at max. 6 ft spans or min. 2,500 psi structural concrete Re-Roof Only: Min. 210 psi, min. 2-inch thick pre-existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve an average withdrawal of 95 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in.) or Drill-Tec Base Sheet Fastener E (1.7 in.), Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in two, equally spaced, staggered center rows Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch applied SBS-TA, APP-TA -82.5 LWC-53. Min. 22 ga., type BV, Grade 40 steel at max. 6 ft spans or min. 2,500 psi structural concrete Re-Roof Only: Min. 210 psi, min. 2-inch thick pre-existent cellular lightweight insulating concrete; Note: To qualify the pre-existent LWIC under this assembly, the selected fastener shall achieve an average withdrawal of 95 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.7 in.), Drill-Tec Locking Impact Nail 7-inch o.c. at min. 4-inch laps and 7- inch o.c. in two, equally spaced, staggered center rows Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch applied SBS-TA, APP-TA -82.5 LWC-54. Min. 22 ga. type B, Grade 33 steel; 5-ft spans or min. 2,500 psi structural concrete Min 250 psi pre-existent cellular LWC with optional min. 1 pcf EPS board and min. 2-inch thick top coat Ruberoid HW Granule (granules down) Note 2 Fasten through LWC to structural deck 12-inch o.c. at 4-inch side laps and 12-inch o.c. in two, equally spaced staggered center rows. (Optional) SBS-TA SBS-TA (polyester, D6164 only) -97.5 TABLE 4D: LIGHTWEIGHT INSULATING CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER SEE NOTE 16A FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Lightweight Concrete (Note 14) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply CELCORE (FL2037): LWC-55. Structural concrete Min. 250-300 psi Celcore Cellular Concrete Matrix 307 Premium Asphalt Primer or ASTM D41 SBS-SA None SBS-TA -52.5 LWC-56. Structural concrete Min. 250-300 psi Celcore Cellular Concrete TOPCOAT PRECOTE SBS-SA None SBS-TA -100.0 ELASTIZELL (FL4994): LWC-57. Structural concrete Min. 250-300 psi Elastizell Lightweight Insulating Concrete Matrix 307 Premium Asphalt Primer or ASTM D41 SBS-SA None SBS-SA -137.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 68 of 101 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-1. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 CWF-2. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 CWF-3. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 CWF-4. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0 SELF-ADHERING BASE PLY: CWF-5. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP-TA -52.5 CWF-6. Existing Tectum (re- roof only) Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP-TA -45.0 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-7. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 69 of 101 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-8. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* CWF-9. Min. 2-inch Tectum I Plank GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 6-inch o.c. at the 3- inch lap and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous), min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or EnergyGuard Perlite Recover Board or min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA SBS-AA -60.0 CWF-10. Min. 2-inch Tectum I Plank GAFGLAS #75 Base Sheet, Tri- Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 6-inch o.c. at the 3- inch lap and 6-inch o.c. in two, equally spaced, staggered center rows Min. 1-inch EnergyGuard Polyiso Insulation Hot asphalt Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 70 of 101 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-11. Existing Tectum (re- roof only) GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -30.0 CWF-12. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS-TA or APP-TA -45.0* CWF-13. Existing Tectum (re- roof only) Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -60.0 CWF-14. Existing Tectum (re- roof only) Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -60.0 CWF-15. Existing Tectum (re- roof only) GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet or Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 CWF-16. Existing Tectum (re- roof only) Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -67.5 CWF-17. Min. 2-inch Tectum I Plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 6-inch o.c. at the 4-inch lap and 6-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- AA or SBS-TA SBS-AA or SBS-TA -75.0 HYBRID HOT/COLD-APPLIED SYSTEMS: CWF-18. Existing Tectum (re- roof only) GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 2-inch lap and 9-inch o.c. at two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 71 of 101 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: G-1. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA (Optional) SBS- TA SBS-TA -190.0 SELF-ADHERING BASE PLY: G-2. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation or EnergyGuard RH OB500 (Optional) Additional layer(s) of base insulation OB500 SBS-SA None SBS-SA -87.5 G-3. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -105.0 G-4. Existing sound gypsum or gypsum plank Min. 1-inch EnergyGuard Polyiso Insulation or EnergyGuard RN OB500 (Optional) Additional layer(s) of base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -147.5 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: G-5. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* G-6. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, #80 Ultima Base Sheet, Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth, Mop Smooth Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 3- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1-inch EnergyGuard Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA, APP-TA SBS-TA, APP-TA -45.0* VENTING SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 72 of 101 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-7. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Min. 1.8-inch Drill-Tec Locking Impact Nail or Drill-Tec Base Sheet Fastener (1.2 in) 9-inch o.c. at the 2- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite Recover Board or min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet BP-AA, SBS-AA SBS-AA or SBS- TA -45.0* G-8. Existing sound gypsum or gypsum plank GAFGLAS Stratavent Nailable Venting Base Sheet Min. 1.8-inch Drill-Tec Locking Impact Nail 9-inch o.c. at the 2- inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt None N/A GAFGLAS Stratavent Perforated Venting Base Sheet Two plies SBS-AA SBS-AA -45.0* TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply G-9. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Drill-Tec Polymer Gyptec Fastener with Drill-Tec Gyptec Plate 1 per 1.3 ft2 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -62.5* TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply CONVENTIONAL SYSTEMS: G-10. Existing sound gypsum or gypsum plank GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -30.0 G-11. Existing sound gypsum or gypsum plank GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows BP-AA, SBS-AA SBS-AA, SBS- TA or APP-TA -45.0* G-12. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 18-inch o.c. in two, equally spaced, staggered center rows SBS-TA SBS-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 73 of 101 TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fastener (Note 11) Attachment Base Ply Cap Ply G-13. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA or APP-TA -50.0* G-14. Existing sound gypsum or gypsum plank Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -60.0 G-15. Existing sound gypsum or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -60.0 G-16. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet or GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Base Sheet Fastener (1.2 in.) 9-inch o.c. at min. 2-inch laps and 9-inch o.c. in three, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA or APP-TA -57.5* G-17. Existing sound gypsum or gypsum plank GAFGLAS Ply 4, GAFGLAS Ply 4 M, Tri-Ply Ply 4 Ply Sheet, GAFGLAS FlexPly 6, GAFGLAS FlexPly 6 M, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet or Ruberoid 20 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 G-18. Existing sound gypsum or gypsum plank Ruberoid HW 25 Smooth Drill-Tec LD Fasteners and Drill-Tec LD Plates 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) SBS- TA SBS-TA -67.5 HYBRID HOT/COLD-APPLIED SYSTEMS: G-19. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 9-inch o.c. at min. 2-inch laps and 18-inch o.c. at two, equally spaced, staggered center rows BP-AA or SBS-AA SBS-CA1 -45.0* G-20. Existing sound gypsum or gypsum plank GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet Drill-Tec Locking Impact Nail 7.5-inch o.c. at min. 2-inch laps and 7.5-inch o.c. at one center rows BP-AA or SBS-AA SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 74 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS WITH BASE INSULATION LAYER ONLY R-1. Existing asphaltic roof cover Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -140.0 R-2. Existing asphaltic roof cover Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-3. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-4. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Composite Hot asphalt BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA SBS-AA, SBS-TA or APP-TA -240.0 R-5. Existing granule surface cap sheet Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 R-6. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -110.0 R-7. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part, 6-inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -157.5 R-8. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-9. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part, 4-inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-10. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-11. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 6-inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-12. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-13. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 4-inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-14. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime GAF 2-Part, 4-inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -200.0 R-15. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-TA (Optional) SBS-TA SBS-TA -245.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 75 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-16. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-17. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-18. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-19. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-20. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime LRF-XF, 4- inch o.c. SBS-TA (Optional) SBS-TA SBS-TA -200.0 R-21. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime LRF-XF SBS-TA (Optional) SBS-TA SBS-TA -245.0 R-22. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -110.0 R-23. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-24. Existing asphaltic roof cover Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -120.0 R-25. Existing asphaltic roof cover Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) One or more SBS-TA SBS-TA -120.0 R-26. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6- inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -157.5 R-27. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-28. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 4- inch o.c. BP-AA, SBS-AA (Optional) One or more BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA or APP-TA -165.0 R-29. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 4- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -200.0 R-30. Existing granule surface cap sheet Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-TA, APP-TA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -240.0 SELF-ADHERING BASE PLY WITH BASE INSULATION LAYER ONLY R-31. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, SBS-TA, APP-TA -90.0 R-32. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 76 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-33. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-34. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA or EnergyGuard RN GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-35. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-36. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-37. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-38. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-39. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 6-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -137.5 R-40. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA or EnergyGuard RN GAF 2-Part, 6-inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-41. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part, 6-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-42. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part, 6-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-43. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part, 4-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -167.5 R-44. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-45. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer GAF 2-Part, 4-inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 77 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-46. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA or EnergyGuard RN GAF 2-Part, 4-inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -200.0 R-47. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RN GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -210.0 R-48. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA GAF 2-Part SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-49. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -75.0 R-50. Existing smooth surfaced BUR or granule surface roof cover Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -75.0 R-51. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-52. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-53. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -200.0 R-54. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0 R-55. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA LRF-XF SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -110.0 R-56. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-57. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-58. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-59. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -137.5 R-60. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -157.5 R-61. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 78 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-62. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-63. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -180.0 R-64. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer LRF-XF, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -180.0 R-65. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA LRF-XF, 4- inch o.c. SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -200.0 R-66. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA LRF-XF SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-TA, APP-TA -217.5 R-67. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -97.5 R-68. Existing asphaltic roof cover or gravel- surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -110.0 R-69. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -110.0 R-70. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-71. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN, Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -110.0 R-72. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-73. Existing asphaltic roof cover Min. 0.25-inch DensDeck, optionally primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-74. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 79 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-75. Existing asphaltic roof cover Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -120.0 R-76. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-77. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -122.5 R-78. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -137.5 R-79. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-80. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN, Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 6- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -157.5 R-81. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RN OB500, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -162.5 R-82. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -167.5 R-83. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500, 4- inch o.c. SBS-SA (Optional) SBS-TA or APP- TA SBS-TA or APP- TA -200.0 R-84. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 SBS-SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -225.0 VENTING SYSTEMS WITH BASE INSULATION LAYER ONLY R-85. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -150.0 R-86. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS- AA SBS-TA or APP- TA -150.0 R-87. Existing smooth- or granule-surface BUR, granule-surface modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 80 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-88. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -172.5 R-89. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP-AA, SBS- AA SBS-TA or APP- TA -172.5 R-90. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-91. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 6-inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 R-92. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -180.0 R-93. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 4-inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-94. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -75.0 R-95. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-96. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 R-97. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 4- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-98. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -225.0 R-99. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-100. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 6- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 R-101. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -180.0 R-102. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 4- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-103. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -110.0 R-104. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 6- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 81 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-105. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 4- inch o.c. GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -200.0 R-106. Existing smooth- or granule-surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP- AA, SBS-AA SBS-AA -225.0 COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY R-107. Existing mineral surface cap or asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -127.5 R-108. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -172.5 R-109. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -110.0 R-110. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -120.0 R-111. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime GAF 2-Part, 6-inch o.c. SBS-CA1 None SBS-CA1 -127.5 R-112. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 6-inch o.c. SBS-CA1 None SBS-CA1 -157.5 R-113. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 4-inch o.c. SBS-CA1 None SBS-CA1 -172.5 R-114. Existing smooth surfaced BUR or granule surface roof cover Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -75.0 R-115. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -110.0 R-116. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -120.0 R-117. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime LRF-XF, 6- inch o.c. SBS-CA1 None SBS-CA1 -127.5 R-118. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. SBS-CA1 None SBS-CA1 -157.5 R-119. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4- inch o.c. SBS-CA1 None SBS-CA1 -172.5 R-120. Existing smooth APP, mineral surface cap, asphaltic BUR or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 SBS-CA1 None SBS-CA1 -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 82 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-121. Existing smooth surfaced BUR / APP modified bitumen, granule surface roof cover or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel over structural concrete deck Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -97.5 R-122. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -110.0 R-123. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -120.0 R-124. Existing smooth APP or mineral surface cap Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 R-125. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime OB500, 6- inch o.c. SBS-CA1 None SBS-CA1 -127.5 R-126. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. SBS-CA1 None SBS-CA1 -157.5 R-127. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -165.0 R-128. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 R-129. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4- inch o.c. SBS-CA1 None SBS-CA1 -172.5 HYBRID HOT/COLD-APPLIED SYSTEMS WITH BASE INSULATION LAYER ONLY R-130. Existing mineral surface cap or asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-131. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-132. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-133. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-134. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime GAF 2-Part, 6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-135. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 6-inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-136. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part, 4-inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-137. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 83 of 101 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE INSULATION LAYER ONLY) System No. Substrate (Notes 1 & 12) Base Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-138. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-139. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime LRF-XF, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-140. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-141. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF, 4- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-142. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-143. Existing asphalt BUR Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-144. Existing smooth APP or mineral surface cap Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-145. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch DensDeck Prime OB500, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-146. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-147. Existing smooth APP Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -165.0 R-148. Existing mineral surface cap Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-149. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4- inch o.c. BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 84 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS (BASE AND TOP LAYER INSULATION): R-150. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA (Optional) BP-AA SBS-AA or SBS- TA -112.5 R-151. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -127.5 R-152. Existing smooth- or granule- surface BUR, granule-surface modified bitumen or smooth- surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, EnergyGuard Perlite Recover Board, min. 0.75-inch EnergyGuard Perlite Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-153. Existing granule surface cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -172.5 R-154. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -172.5 R-155. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch EnergyGuard Perlite Recover Board Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA SBS-AA -187.5 R-156. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -225.0 R-157. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA (Optional) SBS- TA SBS-TA -232.5 R-158. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP- TA APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 85 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-159. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or Min. 1.5-inch EnergyGuard Composite or min. 0.25-inch DensDeck Prime Hot asphalt BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 R-160. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-161. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-162. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board GAF 2-Part BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-163. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-164. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-165. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 R-166. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 4-inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 R-167. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 4-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 86 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-168. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation GAF 2-Part, 4-inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -200.0 R-169. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -225.0 R-170. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -232.5 R-171. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck or DensDeck Prime GAF 2-Part BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 R-172. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -75.0 R-173. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -110.0 R-174. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 87 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-175. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board LRF-M BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-176. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-177. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum Fiber Roof Board LRF-XF BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-178. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-179. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 4- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 R-180. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation LRF-XF, 4- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -200.0 R-181. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -225.0 R-182. Existing asphaltic roof cover Min. 2.0-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -232.5 R-183. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 88 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-184. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-185. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -110.0 R-186. Existing asphalt BUR or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -120.0 R-187. Existing asphalt BUR or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -120.0 R-188. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -150.0 R-189. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Gypsum Fiber Roof Board OB500 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -150.0 R-190. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck or DensDeck Prime OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -150.0 R-191. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-192. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 89 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-193. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -157.5 R-194. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -165.0 R-195. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -165.0 R-196. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 BP-AA, SBS-AA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -165.0 R-197. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -187.5 R-198. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-TA (Optional) SBS- TA SBS-TA -200.0 R-199. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-TA, APP-TA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-200. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -200.0 R-201. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500, 6- inch o.c. BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) One or more BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 SELF-ADHERING BASE PLY WITH POLYISOCYANURATE BASE INSULATION LAYER NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 90 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-202. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-203. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS- SA SBS-SA -110.0 R-204. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-205. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 6-inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-206. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -180.0 R-207. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 4-inch o.c. (Optional) Additional layer(s) base insulation GAF 2-Part SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 R-208. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra GAF 2-Part, 4-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 R-209. Existing smooth-surface BUR over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -75.0 R-210. Existing smooth surfaced BUR or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M- OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -75.0 R-211. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -97.5 R-212. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 91 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-213. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 6- inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-214. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, 4- inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-215. Existing granule-surface BUR or modified bitumen or smooth-surface SBS modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M, M- OSFA Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-M, M- OSFA SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -225.0 R-216. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-217. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS- SA SBS-SA -110.0 R-218. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-219. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 6- inch o.c. (Optional) Additional layer(s) base insulation and/or Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-220. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -180.0 R-221. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 4- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 R-222. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-XF, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 92 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-223. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over structural concrete deck Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -97.5 R-224. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -97.5 R-225. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-226. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA -110.0 R-227. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -110.0 R-228. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- SA SBS-TA or APP- TA -120.0 R-229. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -120.0 R-230. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-231. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS- SA SBS-SA -152.5 R-232. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 6- inch o.c. (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 R-233. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 93 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-234. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -165.0 R-235. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.25-inch DensDeck; surface shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -167.5 R-236. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500, 4- inch o.c. (Optional) Additional layer(s) base insulation OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-237. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -200.0 R-238. Existing smooth- or granule- surface BUR or modified bitumen over concrete deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum Fiber Roof Board OB500 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -225.0 R-239. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA or EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board (primer optional) OB500, 6- inch o.c. SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -240.0 VENTING SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-240. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-241. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.75-inch EnergyGuard Perlite Roof Insulation (homogeneous) Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-242. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-243. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-244. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 94 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-245. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -150.0 R-246. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 R-247. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard Ultra Hot asphalt (Optional) Additional layer(s) base insulation Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -172.5 R-248. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -240.0 R-249. Existing asphaltic roof cover Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra Hot asphalt Min. 0.25-inch DensDeck or DensDeck Prime Hot asphalt GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -240.0 R-250. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 R-251. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-252. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-253. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-254. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-255. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 95 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-256. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part, 6-inch o.c. (Optional) EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-257. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part, 6-inch o.c. (Optional) EnergyGuard Ultra GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-258. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-259. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-260. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part, 4-inch o.c. (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 R-261. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra GAF 2-Part, 4-inch o.c. (Optional) Additional layer(s) base insulation GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -172.5 R-262. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -200.0 R-263. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra GAF 2-Part Min. 0.25-inch DensDeck Prime GAF 2-Part GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -200.0 R-264. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-265. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-266. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 96 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-267. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-268. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 6- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-269. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 6- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-270. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -157.5 R-271. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -157.5 R-272. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 4- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -172.5 R-273. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra LRF-XF, 4- inch o.c. (Optional) Additional layer(s) base insulation LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -172.5 R-274. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -200.0 R-275. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH or EnergyGuard Ultra LRF-XF Min. 0.25-inch DensDeck Prime LRF-XF GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -200.0 R-276. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 97 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-277. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -90.0 R-278. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-279. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500 (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-280. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -110.0 R-281. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -110.0 R-282. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500, 6- inch o.c. (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 R-283. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Ultra OB500, 6- inch o.c. (Optional) Additional layer(s) base insulation OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -150.0 R-284. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet (Optional) One or more BP-AA, SBS-AA SBS-AA -150.0 R-285. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra OB500, 6- inch o.c. Min. 0.25-inch DensDeck or DensDeck Prime OB500 GAFGLAS Stratavent Perforated Venting Base Sheet One or more BP- AA, SBS-AA SBS-TA or APP- TA -150.0 COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-286. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 98 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-287. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-CA1 None SBS-CA1 -127.5 R-288. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -110.0 R-289. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part SBS-CA1 None SBS-CA1 -127.5 R-290. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -157.5 R-291. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 4-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part SBS-CA1 None SBS-CA1 -172.5 R-292. Existing smooth surfaced BUR or granule surface roof cover Min. 1.5-inch EnergyGuard RH LRF-M, M- OSFA Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M, M- OSFA SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -75.0 R-293. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -110.0 R-294. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-M SBS-CA1 None SBS-CA1 -127.5 R-295. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -157.5 R-296. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M SBS-CA1 None SBS-CA1 -172.5 R-297. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -110.0 R-298. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF SBS-CA1 None SBS-CA1 -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 99 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-299. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -157.5 R-300. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF SBS-CA1 None SBS-CA1 -172.5 R-301. Existing asphaltic roof cover or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OB500 SBS-CA None SBS-CA -45.0 R-302. Existing smooth surfaced BUR / APP modified bitumen, granule surface roof cover or gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel over structural concrete deck Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 SBS-CA or SBS-CA1 None SBS-CA or SBS- CA1 -97.5 R-303. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -110.0 R-304. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -120.0 R-305. Existing smooth APP or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 R-306. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime OB500 SBS-CA1 None SBS-CA1 -127.5 R-307. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -157.5 R-308. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -165.0 R-309. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 R-310. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -172.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 100 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID HOT/COLD-APPLIED SYSTEMS WITH POLYISOCYANURATE BASE INSULATION LAYER: R-311. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-312. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Hot asphalt Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-313. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-314. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch DensDeck Prime GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-315. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 6-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-316. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2-Part, 4-inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2-Part BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-317. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-318. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-319. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-320. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-321. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-322. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch DensDeck Prime LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 01506.11.04-R30 for FL5680-R30 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 30: 03/08/2021 ©2019 NEMO ETC, LLC GAF Modified Bitumen Roof Systems; (800) 766-3411 Appendix 1, Page 101 of 101 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER (BASE AND TOP LAYER INSULATION) Sys No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-323. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-324. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH LRF-XF, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-XF BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-325. Existing asphalt BUR Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -120.0 R-326. Existing smooth APP or mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-327. Existing smooth APP Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -165.0 R-328. Existing mineral surface cap Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5 R-329. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -110.0 R-330. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch DensDeck Prime OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -127.5 R-331. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -157.5 R-332. Existing gravel-surfaced BUR, brushed/spudded and vacuumed to remove loose gravel Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500, 4- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-CA1 -172.5