665 SAILFISH DR ROOF21-0083 ,L''''' Building Permit Application Updated 10/9/18 a ?. t:` City of Atlantic Beach Building Department **ALL INFORMATION x V.r 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY 15 `jt IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us 2 Job Address: 6(5 5,t`f �1 ,c `e((A- E- -517, 33 Permit Number:{{�� rr�� F00 P7 Z( - / O e 3 Legal Description �,,-)-(- — `� 0.L PaGy s U mt. 1 1.047 bt.kRE# 17 1 .•2 5 "0000 Valuation of Work(Replacement Cost)$ 13 ,a O? Heated/Cooled SF CO Non-Heated/Cooled • Class of Work: ONew [ Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial Residential • If an existing structure,is a fire sprinkler system installed?: ❑Yes ❑No • Will tree(s)be removed in association with proposed project? ❑Yes(must submit separate Tree Removal Permit) ❑No Describe in detail the type of work to be performed: j{LJ TY'.t \ F- A Or-) /.e \c`.C\neck rag f I 4- A.)Cud SCr- t r. Qom,n-, �1 a0 k :,.�(•. Florida Product Approval# FL. .5 (z �( . R n for multiple products use product approval form Property Owner Information Name e7r4¢2.„ d r rlv✓i'•"d. Address (205 S60 F',*1 DC.ke, e°,.51 City A flo(ntic, V6ae4()) State C], Zip 3 7.7-23 Phone C10,--i 3-A'7 ,\6 l LJ E-Mail NO 1`Tr.T\Df r.Ow-aN C'(`lcl� LD,\ Owner or Agent(If Agent, Po er ofAttorney or Agency Letter Required) Contractor Information Name of Company Rokriet.S L .br, CoA5)%..A..0-... Qualifying Agent W.\be/ (1.5 Address 7L2 1 SLS) ,51P- w(.x L.0-Kr &}Urf City Lc4? 60A\-r/ State FC. • Zip Office Phone .. -et L Z b ~S 1 "1 Job Site Contact Number 9'0c-( /L 2 ^3).35 State Certification/Registration# CZ-C.. ISZnY)\ E-Mail Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Insurer OR Exempt Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.R•ertify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES,BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN A NEY BEFO RECORDING YOUR-NO OF COMMENCEMENT. 4/ (A-/ S', tur or Agent) lc (Signature of Contractor) Signed and sworn to(or affirmed)before me this 11 day;Ff `�Sig an sworn too affir :• bet.re me hi ':ay of D , 4 ,by t ` ca- f►(�U' `.1 ':1L O- , Z 064 b ( I A‘, 1 1 • a.1:*24- 0 l `-v w.',r.ture AMINO ,parroN - • ��'$: .. f„,:.• '.a. •.� MYCOVIAISSION 1 NH OWN "',_ w moo. EXPIRES.Ocbber27,ZOM ;o� v.?�;., TONI GINDL'V ER '',i`•' Bonded PersonallyKnown OR s2• „ .�, [ ]Per ovally Known OR *lay ,: :*: MY COMMISSION# G 353178 [ roduced Identification ]Produced Identification :,,,,:!s,;;;.1..,,, EXPIRES:October 6,2023 Type E ( JL.,; LLLnS..Q Type of Identification: _F„' 'c: Ben::dedThruNotary Public Underwriters T e of Identification: (- �� MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 LOCAL 904-358-8366 WATTS 1-877-358-Roof (7663) FAX 904-358-8285 MMI2000.NET 5-V CRIMP — Net Coverage 24" 12" NOM. (±1/4") 1/2" Net Coverage 24" 5 1/4" — 1/2" MILLENNIUM - VFLAt-d FL ,C27/ ANTI—SIPHON CHANNEL HMI MENMININ -115lihmillhimmommum ■ if Sidelap Detail PITCH ALERT: THIS PRODUCT SHOULD NOT BE USED ON APPLICATIONS LESS THAN 3:12 PITCH WITHOUT A SECONDARY UNDERLAYMENT SUCH AS PEEL& SEAL AND SIDE LAP SEALANT APPLIED TO ANTI-SIPHON CHANNEL. THE MINIMUM PITCH ALLOWANCE WITH THE SECONDARY UNDERLAYMENT AND SIDE LAP SEALANT IS 2:12. Specifications: Gauge Finishes Nominal Thickness ASTM & Grade Specifications 29 Galvanized .0142 ASTM A-653 Grade 80 Structural Steel 26 Galvanized .0185 ASTM A-653 Grade 80 Structural Steel 26 Acrylic Galvalume .0185 ASTM A-792 AZ55 Grade 80 Structural Steel 26 PTD Galvanized * .0185 ASTM A-755 Grade 80 Structural Steel PTD Material is siliconized polyester unless otherwise noted. Millennium Metals Offers a Limited 40 year warranty on Painted Panels,25 year limited warranty on Mill Finished Galvalume Panels. Please request warranty information from your distributor. *26 Gauge Colors:Red,White,Gray,Hunter Green,Patina Green,Burnished Slate MILLENNIUM METALS INC. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 MMI2000.NET SUBJECT TO CHANGE WITHOUT NOTICE PAGE 1 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 • LOCAL 904-358-8366 WATTS 1-877-358-Roof (7663) FAX 904-358-8285 MMI2000.NET 5-V CRIMP Installation Instructions: 5-V CRIMP PANEL FASTENING RECOMMENDATIONS DetailB 1%211 OSB BOARD OR PLYWOOD i�\-7\ Detail C 15/32° OSB BOARD OR PLYWOOD Roof Application: I) Step 1:Make sure the deck is even and square. Millennium Metals recommends the use of a minimum'A"plywood or OSB board attached in accordance with code. The deck must be supported by an engineered truss system not to exceed 24"on center. A moisture barrier such as 30#felt or other ASTM approved underlayment should be used over decking to control moisture. Metal should never come in direct contact with green or pressure treated lumber,as it will cause corrosion. If tin tabs are required to attach felt it will be necessary to apply a 15#felt in the direction of the panel as an additional separation barrier. Step 2:Install Eave Drips/Roof Edge and Valleys according to details. Remember to use inside closure strips between Eave and Panel to eliminate water infiltration. Step 3:Panel placement should begin on the gable end opposite the prevailing wind.Starter edge should be the lap edge. (Opposite of Purlin Bearing Leg)After laying first panel,check for squareness. Panel 2 should be lapped over purlin bearing leg of panel 1 with the lap edge. A minimum of 1"overhang is recommended at the eave. Alternative method of panel placement may begin in the center of the roof. Often this method is used when the area to be covered is not divisible by 2 ft.or traditional placement allows for a pipe flashing to occur in a side lap. Endlaps must be a minimum of 12"and two strips of butyl sealant tape is recommended 8"on the uphill side of the lap to keep watertight. The fastener should be placed between the butyl tape strips. Step 4:Fasten panel according to detail B or C based on approved solid substrate selection. Detail C shows additional screws to be spaced on each side of major ribs for all eaves,ridges,and endlaps. Florida Product Approval requires the substrate to be plywood. Step 5:Any field cutting must be done with metal nibblers,metal snips,or blades designed for metal cutting. No cutting should be done on the roof,as it will cause iron shavings to be spread and adhere to roof panels. Proper cutting should be done with the panels fmished side down. Do not use graphite,lead,or any other marking devices that may stain panel and void warranty. Step 6:Install the remaining accessories such as pipe boots;5-V profile vents,ridge caps,gable flashings,butyl sealants,caulks,and closures are necessary to maintain watertight seals. Inspect screw fasteners to insure that they are installed properly. MILLENNIUM METALS INC. TOLL FREE:1-877-358-7663 FAX:904-358-8285 MMI2000.NET SUBJECT TO CHANGE WITHOUT NOTICE PAGE 2 1111 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 LOCAL 904-358-8366 WATTS 1-877-358-Roof (7663) FAX 904-358-8285 MMI2000.NET Step 7:Fasteners should penetrate deck material by 1/4" FASTENERS CORRECT TOO LOOSE TOO TIGHT I I I II II Aproximate Screw Chart 1111.11.1' JILL_ 1532"Plywood=250 screws per square EPDM MATERIAL EPDM NOT AT EPDM IS '/32"Plywood—150 screws per square VISIBLE AT VISIBLE JOINT. PANNED AND IS 50 Lineal Feet=t Square WASHER. NOT ENOUGH PROTRUDING FASTENER IS COMPRESSION BEYOND EDGE PROPERTY TO MAKE A SEAL. OF FASTENER. INSTALLED. Attention Installer: Please refer to the important notes section of this manual for safety,storage,oil canning disclaimer, shaving disclaimer and underlayments prior to beginning this project. • Important Notes: Code Requirements vary from project type and location. Millennium Metals recommends licensed roofing professionals to install materials. It is the responsibility of the roofing contractor to meet all prescriptive requirements if not indicated in our recommendations. Safety when using metal materials is imperative. It is necessary to inspect deck integrity to insure it is safe to walk on before beginning any work. Never walk on material when wet or unsuitable weather conditions are present. Millennium Metals recommends the use of gloves and eye goggles when working handling materials. OSHA fall protection should be strictly adhered to on all projects. Job Specific engineering should be considered for any Florida application not installed according to Florida product testing. Millennium Metals Inc has a third party engineer who can provide this documentation for a nominal fee. Millennium Metals Inc.accepts no responsibility for the information provided. Florida Product Testing Millennium Metals Inc.has Florida Product approval over'h"and 5/8"plywood. The current product approval is available on our website at mmi2000.net.Figure 2-1 and 2-2 indicate attachment for these approvals. Fastener length for new construction should be a minimum of 1- 1/2"in the field of the project. The length of the fastener should penetrate the plywood a minimum of a'/d". Re-Roofing Over Shingles If re-roofing over one layer of shingles with''/2"or 5/8"plywood and felt a minimum of a 2-1/2"fastener should be used. A Limited Warranty is available on Acrylic Galvalume and Pre-painted materials. A copy of this warranty is available to review at our website mmi2000.net. Failure to request warranty indicates customer accepts conditions stated within the • warranty. Millennium Metals warrants material only. Long life fasteners are required in warranty content. Please consult us if you have any questions regaurding fastener selection. Watertight warranties are not available. • MILLENNIUM METALS INC. TOLL FREE:1-877-358-7663 FAX:904-358-8285 MMI2000.NET SUBJECT TO CHANGE WITHOUT NOTICE PAP.F MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 • LOCAL 904-358-8366 WATTS 1-877-358-Roof (7663) FAX 904-358-8285 MMI2000.NET r RIDGE PITCH CHART 312 161' �2 152' 4%2 143' - e3 sia m i m m iliki; iimiessii fp.H polo op op.. 5/2 134' \\\\\\ S �.� \\\\` i . v 642 12T 4% / 4f HIP / RIDGE FLASHING ♦///',, //// UNDERLAYMENT /.�♦ / //// PANEL / ��j// / BUTYL TAPE SEALANT ♦/O♦/// // 5-V OUTSIDE CLOSURE ♦/�/// FASTENER, 12" O.C. MAX. HIP / RIDGE DETAIL RC- 1 * 1 BOX VERSA VENT = 100 L.F. VENT = 50 L.F. RIDGE 4mmmiiii444 �\ ' ® iii IN 4/4 �� HIP / RIDGE FLASHING // /// UNDERLAYMENT ♦///•//♦// // PANEL ♦j// //// VERSA VENT VENTING MATERIAL ♦///♦/ // FASTENER, 12" 0.C. MAX. ♦////// VENTED RIDGE DETAIL RC-6 • MILLENNIUM METALS INC. We stock screws,closures,touch up paint,pipe boots,butyl tape,ventilation and other accessories. TOLL FREE:1-877-358-7663 FAX:904-358-8285 MMI2000.NET SUBJECT TO CHANGE WITHOUT NOTICE PAGE 8 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 LOCAL 904-358-8366 WATTS 1-877-358-Roof (7663) FAX 904-358-8285 MMI2000.NET u PANEL UNDERLAYMENT FASTENER, 12" O.C. 1� °0. 5—V INSIDE CLOSURE SET IN SEALANT 'I EAVE FLASHING FASCIA EAVE DRIP DETAIL ED- 1 - 110. V\ PANEL • UNDERLAYMENT FASTENER, 12" O.C. 5—V INSIDE CLOSURE SET IN SEALANT EAVE FLASHING FASCIA • ROOF EDGE DETAIL EF-3 MILLENNIUM METALS INC. We stock screws,closures,touch up paint,pipe boots,butyl tape,ventilation and other accessories. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 MMI2000.NET SUBJECT TO CHANGE WITHOUT NOTICE PAGE 9 MILLENNIUM METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 • LOCAL 904-358-8366 WATTS 1-877-358-Roof (7663) FAX 904-358-8285 MMI2000.NET PANEL FASTENER, 12" 0.C. MAX. BUTYL TAPE SEALANT L► GABLE FLASHING �� UNDERLAYMENT �♦'.'�//// FASTENER, 12" 0.C. MAX. FASCIA I I GABLE DETAIL GR-4 WALL SEALANT COUNTER—FLASHING (SEE NOTE) FASTENER, 12" 0.C. MAX. BUTYL TAPE ��t SIDEWALL FLASHING FASTENER, 12" 0.C. MAX. BUTYL TAPE ‘111114' k\\\\ PANEL UNDERLAYMENT u NOTE: COUNTER—FLASHING `\ OPTIONAL WHERE WALL COVERING CAN'T BE APPLIED OVER FLASHING WALL FLANGE. SIDEWALL DETAIL SW- 1 MILLENNIUM METALS INC. We stock screws,closures,touch up paint,pipe boots,butyl tape,ventilation and other accessories. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 MMI2000.NET SUBJECT TO CHANGE WITHOUT NOTICE PAGE 11 MILLENNIUM 6111111111/11 METALS, INC. 10200 EASTPORT ROAD JACKSONVILLE, FL 32218 • LOCAL 904-358-8366 WATTS 1-877-358-Roof (7663) FAX 904-358-8285 MMI2000.NET TRANSITION DETAIL TF- 1 ‘ PANEL =4 UNDERLAYMENT \ ...... STAKING FASTENER BUTYL TAPE =_ 5—V INSIDE CLOSURE \ TRANSITION FLASHING /N . 11..40111‘11%0 PANEL /4 / BUTYL TAPE 5—V OUTSIDE CLOSURE •///�//%V / /! • COUNTER—FLASHING (SEE NOTE) / FASTENER, 12" 0.C. MAX. BUTYL TAPE TRANSITION / ' ENDWALL PITCH HEADWALL FLASHING CHART r_______:41 3ti2 104' 442 108' 5/Z 1 13' , kS ii *' 4/ 642 117' PANEL FASTENER, 12" 0.C. MAX. 441I 1 NOTE: COUNTER—FLASHING OPTIONAL WHERE WALL I 5 V OUTSIDE CLOSURE COVERING CAN'T BE APPLIED OVER FLASHING WALL FLANGE. UNDERLAYMENT ENDWALL DETAIL EW-1 •' MILLENNIUM METALS INC. We stock screws,closures,touch up paint,pipe boots,butyl tape,ventilation and other accessories. TOLL FREE: 1-877-358-7663 FAX:904-358-8285 MMI2000.NET SUBJECT TO CHANGE WITHOUT NOTICE PAGE 12