Loading...
135 Pine St RESO21-0083 Demo Screen RoomOWNER:ADDRESS:CITY:STATE:ZIP: GOLDSCHMIDT SONDRA ATLANTIC BEACH FL 32233-4011 COMPANY:ADDRESS:CITY:STATE:ZIP: IMPACT ENCLOSURES INC 11653 Central Parkway Jacksonville FL 32224 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170636 0100 SALTAIR SEC 03 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 135 PINE ST RESIDENTIAL OTHER SINGLE OR TWO FAMILY RESIDENTIAL OTHER DEMO EXISTING SCREEN ENCLOSURE AND BUILDING NEW WITH SLAB $13597.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 10/29/2021 PERMIT NUMBER RESO21-0083 ISSUED: 10/29/2021 EXPIRES: 4/27/2022 RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING PERMIT 455-0000-322-1000 0 $120.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $60.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.45 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.30 TOTAL: $235.75 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 4 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 5 PUBLIC WORKS DECKING REMOVED INFORMATIONAL Notes: All old decking and debris must be removed from job site by Contractor. 2 of 2Issued Date: 10/29/2021 PERMIT NUMBER RESO21-0083 ISSUED: 10/29/2021 EXPIRES: 4/27/2022 RESIDENTIAL OTHER PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 RESO21-0083 RESO21-0083 RESO21-0083 RESO21-0083 23' 10"8' 12 ' 3 " Composite Roof Screen Room All setbacks are measured to walls 11 ' 6 " 2' 0 " RESO21-0083 This item has been electronically signed and sealed by Harold W Coffield,PE on using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 2020 Florida Building Code, Category 1 Top View Top View Right ViewLeft View Goldschmidt Residence 135 Pine St Atlantic Beach, FL 32233 Builder: Impact Enclosures Exposure: C Wind Zone: 120 mph New Concrete 3' 0" 9' 0" 8' 7" 14' 0" 7' 8 " 3' 0 " 8' 7 " 9' 0 " 3' 0" 8' 7" 9' 0" 12' 3" 6' 2"6' 2" 1x2 TYP 2x2 TYP 2x3 TYP 2x 3 S P 2x 3 S P 2x 4 2x3 SP2x3 SP 1x2 1x2 1x 2 T Y P 2x 2 T Y P 1 x 2 T Y P 2 x 2 T Y P 3' Composite Roof 2 x 3 T Y P 2 x 3 T Y P DocuSign Envelope ID: 84BCF5C4-FA6F-45F7-974F-696953DA6F33 9/30/2021 CONTINUOUS CANT BEAD OF COMPATIBLE SEALANTEXIST I N G RAFTE ROR TR U S S 2X2X1/5’’ CONTINOUS ANGLE TOP AND BOTTOM #10x3/4’ SMS @ 6” O.C. TOP AND BOTTOM 1/4” LAG BOLT TOP AND BOTTOM THROUGH RECEIVING CHANNEL @12” O.C. ROOF PANEL ATTACHMENT - WOOD FRAME1 2 2” NOMINAL STRUCTURAL FASCIA MIN. CONTINUOUS CANT BEAD OF COMPATIBLE SEALANT #10X3/4” SMS @ 12” O.C. TOP ROOF PANEL ATTACHMENT - WOOD FRAME 3 ROOF PANEL JOINT SEAL JOINT W/ COMPATIBLE SEALANT 4 1/4” LAG BOLTS @ 12” O.C. W/ 1 1/2” MIN. WASHER DIAMETER, 1” MIN. LONGER THAN PANEL THICKNESS. POST TOP PLATE FASTEN MIN. 2”X2”X1/8” ALUMINUM ANGLE W/ (3)#10x1 SMS TO TOP PLATE ON EACH SIDE OF POST. CARRIER BEAM & SUPER GUTTER CONNECTION DETAIL SHEET 1 5 6 GUTTER & SMB ATTACHMENT (2X8 & LARGER) PURLIN ATTACHMENT (2X8 & LARGER) BEAM IS ATTACHED TO GUTTER W/ 2X2X1/8” RECEIVING CHANNEL. (5)#10X1” INTO GUTTER. ONE LESS #10X1” THAN SIZE OF BEAM INTO BEAM. SMB 2” GUTTER STRAP IS ATTACHED TO GUTTER W/ (3) #10 X 2” EACH SIDE (1)#10 X 2” SMS SCREW @ 24” O.C. ENTIRE LENGTH OF GUTTER MIN. 2X6 NOM. STRUCTURAL FACIA BEAM PURLIN PURLIN IS ATTACHED TO GUTTER / FASCIA & BEAM W/ 1”X2” INTERNAL CLIP OR EXTERNAL C-CHANNEL 2” GUTTER STRAP IS ATTACHED TO GUTTER W/ (3) #10 X 2” EACH SIDE MIN. 2X6 NOM. STRUCTURAL FACIA 2” NOMINAL STRUCTURAL FASCIA MIN 1/4”X3 LAG BOLT THROUGH RECEIVING CHANNEL @ 12” O.C. 3” RECEIVING CHANNEL (1)#10 X 2” SMS SCREW @ 24” O.C. ENTIRE LENGTH OF GUTTER EXIS T I N G R A F T E R OR T R U S S Harold W Coffield, PE 2743 Anniston Rd Jacksonvile, FL 32246 904-343-3052 FL PE #50407 2020 Florida Building Code, Category 1 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 84BCF5C4-FA6F-45F7-974F-696953DA6F33 TYPICAL INTERNAL/EXTERNAL GUSSET (2X8 & LARGER)7 MIN. 2X6 NOM. STRUCTURAL FACIA GUTTER & SMB ATTACHMENT (2X7 SMB & SMALLER)8 PURLIN ATTACHMENT (2X7 SMB & SMALLER)9 PURLINS ATTACHED TO BEAM W/ (4) #10 X 1” SELF TAPPING SCREWS. Harold W Coffield, PE 2743 Anniston Rd Jacksonvile, FL 32246 904-343-3052 FL PE #50407 2020 Florida Building Code, Category 1 DETAIL SHEET 2 TYPICAL INTERNAL/EXTERNAL GUSSET (2X7 SMB & SMALLER)10 PURLIN DETAIL OPTIONS11 12” LONG X 3/18” THICK ALUMINUM INTERNAL OR EXTERNAL GUSSET EACH SIDE. WIDTH TO MATCH BEAM BEAM IS ATTACHED TO GUTTER W/ 2X2X1/8” RECEIVING CHANNEL. (5)#10X1” INTO GUTTER. ONE LESS #10X1” THAN SIZE OF BEAM INTO BEAM. PURLINS ATTACHED TO BEAM W/ (4) #10 X 3/4” SELF TAPPING SCREWS (16) #14 X 3/4” SMS EACH LEG OF GUSSET (32 SMS TOTAL) #14 X 3/4” SELF MATTING SCREWS @ 6” FROM ENDS. 24” O.C. 2” GUTTER STRAP IS ATTACHED TO GUTTER W/ (3) #10 X 2” EACH SIDE (1) #10 X 2” SMS SCREW @ 24” O.C. ENTIRE LENGTH OF GUTTER PURLIN DETAIL OPTIONS12 PURLIN IS ATTACHED TO GUTTER/FASCIA & BEAM W/ 1”X2” INTERNAL CLIP OR EXTERNAL C-CHANNEL 12” LONG X 3/16” THICK ALUMINUM INTERNAL OR EXTERNAL GUSSET EACH SIDE. WIDTH TO MATCH BEAM (10) #10X1” SMS EACH LEG OF GUSSET (20 SMS TOTAL) #10 X 1-1/4” SELF MATING SCREWS @ 6” FROM ENDS. 24”” O.C. BEAM PURLIN 2” GUTTER STRAP IS ATTACHED TO GUTTER W/ (3) #10X2” EACH SIDE (1) #10X2” SMS SCREW @ 24” O.C. ENTIRE LENGTH OF GUTTER MIN. 2X6 NOM. STRUCTURAL FACIA BEAM PURLIN TOP PLATE 2X2X1/8 ANGLE ATTACHED TO COLUMN & BEAM W/ (3) #10X1” PER SIDE. COLUMN PURLIN IS ATTACHED TO TOP PLATE / BEAM W/ 1”X2” INTERNAL CLIP OR EXTERNAL C-CHANNEL FASTEN W/ (4) #10X3/4” PURLIN IS ATTACHED TO TOP PLATE / BEAM W/ 1”X2” INTERNAL CLIP OR EXTERNAL C-CHANNEL FASTEN W/ (4) #10X3/4” (3) #10X3/4” FROM U-CHANNEL TO TOP PLATE PURLIN BEAM (3) #10X3/4” ATTACHES U-CHANNEL TO POST ON EACH SIDE COLUMN 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 84BCF5C4-FA6F-45F7-974F-696953DA6F33 SMB COLUMN CONNECTION OPTIONS 14 SMB COLUMN CONNECTION OPTIONS CABLE CONNECTIONS AT CORNER15 SELF MATING BEAM 13 PURLIN & CHAIR RAIL IS ATTACHED TO BEAM W/ INTERNAL CLIP W/ (1) #10X3/4” TOP & BOTTOM & W/ (2) #10x3/4” TO BEAM PURLIN CHAIR & RAIL CONNECTION OPTIONS16 Harold W Coffield, PE 2743 Anniston Rd Jacksonvile, FL 32246 904-343-3052 FL PE #50407 2020 Florida Building Code, Category 1 DETAIL SHEET 3 19 BOTTOM PLATE & COLUMN ATTACHMENT TOP PLATE U-CHANNEL ATTACHED TO COLUMN W/ (3) #10X1” PER SIDE AND (3) #10X1” INTO TOP PLATE COLUMN #10X3/4” INTO COLUMN & BEAM W/ (1) LESS THAN BEAM SIZE PER SIDE COLUMN #10X3/4” INTO COLUMN & BEAM W/ (1) LESS THAN BEAM SIZE PER SIDE SELF MATING BEAM(4) #10X2” SCREWED THROUGH BEAM, POST, & TOP PLATE (9) #10X3/4” SMS 7”X7” X 1/8” MIN ANGLE BRACKET ON 45° ANGLE 5/16” EYE BOLT WELDED CLOSED WITH DOUBLE NUTS & DOUBLE COMPRESSION SLEEVE. COLUMN PURLIN CHAIR & RAIL CONNECTION OPTIONS17 PURLIN & CHAIR RAIL IS ATTACHED TO BEAM W/ INTERNAL CLIP W/ (1) #10X3/4” TOP & BOTTOM & W/ (2) #10x3/4” TO BEAM 18 SELF MATING UPRIGHT COULMN FOUNDATION 2” MIN SCREWD THROUGH ANGLE TO COLUMN W/ (3) #10X1” SELF MATING SCREW ON EACH SIDE. 1X2 BOTTOM PLATE FASTEN MIN. 2”X2”X1/8” ALUMINUM ANGLE TO SLAB W/ (2) 1/4” TAPCONS ON EACH SIDE OF COLUMN. (MIN. TAPCON EMBEDMENT INTO SLAB -2”) COLUMN 1X2 BOTTOM PLATE FOUNDATION 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 84BCF5C4-FA6F-45F7-974F-696953DA6F33 S.S. CABLE ATTACHMENT20 RISER / KNEE WALL CONNECTION23 Harold W Coffield, PE 2743 Anniston Rd Jacksonvile, FL 32246 904-343-3052 FL PE #50407 2020 Florida Building Code, Category 1 DETAIL SHEET 4 3” A.S.T.M. A-36 STEEL CLIP W/ (2)2”X1/4” TAPCONS 1/8” S.S. CABLE W/ DOUBLE NUTS & DOUBLE COMPRESSION SLEEVES 45° DEGREE ANGLE 1X2 BOTTOM PLATE FASTENED TO FOUNDATION W/ 1/4” TAPCONS 24” O.C. (MIN. TAPCON EMBEDMENT INTO FOUNDATION -2”) 2”X2” HEAVY WALL ANGLE ATTACHED TO GUTTER W/ (4) #10X3/4 “ SCREWS ON EACH SIDE OF COLUMN GUTTER STRAP ATTACHED TO GUTTER W/ (2) #10X2” INTO BACK OF GUTTER THRU FASICA & W/ (2) #10X3/4” INTO FRONT OF GUTTER COLUMN ATTACHED TO HEAVY ANGLE W/ (1) LESS #10X3/4” THAN SIZE OF COLUMN ON EACH SIDE BOTTOM PLATE & COLUMN ATTACHMENT AT PAVERS 2” MIN 21 22 S.S. CABLE ATTACHMENT AT PAVERS COLUMN SCREWD THROUGH ANGLE TO COLUMN W/ (3) #10X1” SELF MATING SCREW ON EACH SIDE. 1X2 BOTTOM PLATE PAVERS ON CONCRETE FOOTING FASTEN MIN. 2”X2”X1/8” ALUMINUM ANGLE TO SLAB W/ (2) 1/4” TAPCONS ON EACH SIDE OF COLUMN. (MIN. TAPCON EMBEDMENT INTO SLAB -2”) 1X2 BOTTOM PLATE FASTENED TO FOUNDATION W/ 1/4” TAPCONS 24” O.C. (MIN. TAPCON EMBEDMENT INTO FOUNDATION -2”)45° DEGREE ANGLE 1/8” S.S. CABLE W/ DOUBLE NUTS & DOUBLE COMPRESSION SLEEVES 3” A.S.T.M. A-36 STEEL CLIP W/ (2)2”X1/4” TAPCONS 1” PLATE PAVERS ON CONCRETE FOOTING FOUNDATION 2’ 3/8” PAVER 2” EMBEDED 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 84BCF5C4-FA6F-45F7-974F-696953DA6F33 Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 NEW CONCRETE DETAIL SHEET 1 1 4” CONCRETE 2 4” CONCRETE W/ 6” EDGE 3 4” CONCRETE W/ 8”X8” FOOTING NE W C O N C R E T E 4 ” T H I C K 8” T h i c k e n e d E d g e ( 1 ) # 5 RE B A R 3 0 0 0 P S I NEW CONCRETE 4” THICK 8" Thickened Edge (1) #5 REBAR 3000 PSI NEW CONCRETE 4” THICK 6” THICKENDED EDGE 3000 PSI NE W C O N C R E T E 4 ” T H I C K 6” T H I C K E N D E D E D G E 300 0 P S I NEW CONCRETE 4” THICK 3000 PSI NE W C O N C R E T E 4 ” T H I C K 300 0 P S I 4 12"X12" FOOTING W/ PAVERS NE W P A V E R S 12 ” X 1 2 ” F O O T E R WI T H 1 # 5 T H R U O U T PAV E R S NEW PAVERS 12”X12” FOOTER WITH 1 #5 THRU OUT 5 BLOCK STEM WALL & FOOTING ALUMINUM STRUCTURE 2"2" CMU BlOCK UP TO 42"H REBAR EXTENDING UP FROM FOOTING EVERY 4'. FILLED W/ CONCRETE #5 REBAR EMBEDDED IN CONCRETE ALONG TOP ROW OF BLOCK #5 "L" SHAPE REBAR EMBEDDED INTO FOOTING TURNED UP THRU CMU BLOCKS. 4’ SPACING (2) #5 REBAR ALONG FOOTING. SEATED 2" ABOVE BOTTOM OF FOOTNG 16" FOOTING 2500 PSI CONCRETE Up To 42" ALUMINUM STRUCTURE 2"2" CMU BlOCK UP TO 42"H REBAR EXTENDING UP FROM FOOTING EVERY 4'. FILLED W/ CONCRETE #5 REBAR EMBEDDED IN CONCRETE ALONG TOP ROW OF BLOCK #5 "L" SHAPE REBAR EMBEDDED INTO FOOTING TURNED UP THRU CMU BLOCKS. 4’ SPACING (2) #5 REBAR ALONG FOOTING. SEATED 2" ABOVE BOTTOM OF FOOTNG 16" FOOTING 2500 PSI CONCRETE Up To 42" 16" GRADE 16" GRADE 6 RAISED SLAB OR PAVERS W/ BLOCK STEM WALL & FOOTING SLAB OR PAVERS 7 12"X12"X12" SPOT FOOTING #5 REBAR X PATTERN 12”X12”X12” POURED CONCRETE 3' 2' 2' PO S T 2500 PSI CONCRETE POST SUNKEN 24" INTO CONCRETE 9 SPOT FOOTING SUNKEN POST #5 REBAR X PATTERN 18”X18”X18” POURED CONCRETE 8 18"X18"X18" SPOT FOOTING 2020 Florida Building Code, Category 1 DocuSign Envelope ID: 84BCF5C4-FA6F-45F7-974F-696953DA6F33 Harold W Coffield, PE 2743 Anniston Rd Jacksonville, FL 32246 904-571-7106 FL PE #50407 2020 Florida Building Code, Category 1 Concrete Layout Goldschmidt Residence 135 Pine St Atlantic Beach, FL 32233 Builder: Impact Enclosures Exposure: C Wind Zone: 120 mph New Concrete New 12"x12" Footer W/ (1) #5 Rebar 8' 2 " 12' 7" DocuSign Envelope ID: 84BCF5C4-FA6F-45F7-974F-696953DA6F33 Roof Installation Instructions Note: Prior to installation please check underneath the first row of shingles to make sure the drip edge is properly sealed. A licensed roofer may be needed if there is a problem with the seal. I. Preparing the Header Channel Run the specified header along the wall of the house, resting it on the beam or channel. Allow for the roof overhang at each side and mark. Remove header, cut to size, pre drill for fasteners and apply two continuous lines of sealant to backside of header. Secure to existing wall. When attaching to fascia make sure that a 1/2” minimum is left between the bottom edge of roof edge trim (P.E.T.) and the top flange of header. (See figure 1 & 3) V A R I E S PRE-DRILLED HOLES @ EQUAL STAGGERED SPACING FOR CONNECTION TO FASCIA THERMAL BREAK ELITE PANEL INSERTED AND FASTENED TO HEADER ELITE R O O F P A N E L TOP BOTTOM CONTINUOUS LINE OF STRUCTURAL GRADE ADHESIVE FIGURE 1 TWO CONTINUOUS LINES OF STRUCTURAL GRADE ADHESIVE SEALANT APPLIED TO BACK OF HEADER PLAN VIEW FOR PANEL COVERAGE 11'48"48"48"48"22 7 8" COVERAGECOVERAGE COVERAGE SIDE WALL IF USED O.H. O.H. 2147 8" HEADER Note: To determine header length - multiply the number of full panels by 48”. If any partial panels are used confirm the coverage with a tape measure. Roof Installation Instructions B. When attaching the header to the fascia board make sure the header is installed a 1/2” below the drip edge. This is critical for keeping water from being trapped between the header and the drip edge. FIGURE 3 EXIST. ROO F D E C K EXIST. STRUCTURE 1/2" MIN. FASCIAHEADER ROOF EDGE TRIM SHINGLESC. Before installing the roof panels apply a continuous bead of sealant to the underside of the header channel. See figure #4. III. Roof Panel Installation A. Place roof panel #1 on front wall and slide panel into the header channel. Make top of front wall is protected (box end of Elite panel) so the panel does not scratch. It is suggested that the female edge will always attach into the male edge. 1/2" PER FT SLOPE FIGURE 2 1' 10' KNEE WALL (TYP) OUTER SUPPORT 8' HEADER ELITE INSULATED ROOF O/H 7'7" II. Attachment to the Fascia A. Preferred slope for the Elite roof panels is a 1/2” per foot. Notice in #2 with a roof span of 10’ the outside wall is 5” shorter than the fascia height. B. Square and secure panel #1 to facilitate the isolation of the remaining panels. At this time you may want to run a bead of sealant in the male recess before locking the next panel into place (See figure#4). Roof Installation Instructions IV. Sealing The System A. Apply generous beads of sealant where the header attaches to the fascia or wall. B. Apply sealant to the top facing of the panel to the header (see figure #1). C. Each panel seam (see figures 5). D. Keep in mind that a sealant tape may be used in addition to all these connections (see figure 6) E. Please remember to use denatured alcohol to remove the wax finish prior to applying sealant to the panel. Prior to running the sealant make sure you wipe down panels with a denatured alcohol where you plan to run the sealant. Place second panel onto the front wall, stay 1/2” outside of header. Raise male edge of panel 8 to 12 inches maintaining top female facing in the male recess for the full length of the panel. See figure #4 above. Allow the panel to come down until it rests on the front wall. During this process you will here a distinct “Click” indicating that the bottom facings have engaged. Slide panel into header and then push to panel #1. This will close the seam and allow the panels to properly interlock. Repeat process until all panels are in place. Square and secure panels according to the engineering plans. 1/4" Bead Min. Rotate to lock 4" to 6" FIGURE 4 INTERLOCK / UNIVERSAL LOCK Roof Installation Instructions FIGURE 7 ELITE ADJUSTABLE RIDGE BEAM ADJUSTABLE FROM 1:12 TO 7:12 SLOPE ELITE ROO F PANEL ELITE R O O F PANEL SEE MASTER PLAN FOR ATTACHMENT DETAILS V. Attachment of Gutters and Fascia A. The attachment of E-gutter and E-fascia are shown in figure #9. Fasten according to the size and spacing shown on the engineering. B. The attachment of the drip edge fascia is shown in figure #10. Fasten this according to the engineering. The drip edge will be used on all three sides of roof and will receive a house gutter. C. Sealing of the fascia and gutters are shown in figures 9-10. SEALANT TAPE NOTE: SEALANT TAPE MAY ALSO BE USED ON ALL JOINTS IN ADDITION, OR INSTEAD OF LIQUID SEALANT FIGURE 6 SEALANT TAPE FIGURE 5 PANEL LOCKING Fill with one part polyurethane or thermo-plastc adhesive sealant Sealant will exude slightly at seam Use for all Gable and A-Frame installations Roof Installation Instructions Panel Panel FIGURE 9 PANEL WITH GUTTER SEAL PRIOR TO APPLICATION TO PANEL SEAL SEAL PRIOR TO APPLICATION TO PANEL SEAL GUTTER FASCIA SEAL PRIOR TO APPLICATION TO PANEL FIGURE 10 PANEL WITH DRIP-EDGE FASCIA WEEP HOLES TO BE DRILLED IN BOTTOM SEAL PANEL (TYP) HOUSE GUTTER NOTE: Flashing is not recommended; however, if you must, please involve a licensed roofer to insure correct procedure is followed. D. One thing to keep in mind when choosing to use E-gutter- and E-fascia. In heavy rains the water can accumulate very quickly on top of the roof and not exit the gutter fast enough. Because the E-gutter and fascia rise above the roof 2 inches, you may have as much as 2 inches of water sitting on the roof with no place to exit. Consequently water can possibly find its way into the room. E. At Elite we suggest using new and improved drip edge fascia with a weep (see figure #10). The drip edge does not sit above the roof thus allowing heavy amounts of water to exit the roof and into the gutter. Also the drip edge is equipped with a 1/2” channel that sits below the panel to drain any excess water that would enter into the panel.