Loading...
962 Ocean Blvd ROOF21-0087 Shingle, TPOOWNER:ADDRESS:CITY:STATE:ZIP: HALVORSEN JOSEF DANIEL 1895 ATLANTIC BEACH DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: RELIANT ROOFING INC 8000 Belfort Parkway Suite 200 Jacksonville FL 32256 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170343 0100 ATLANTIC BEACH PARKWAY JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 962 OCEAN BLVD ROOF NON SHINGLE SHINGLE AND TPO ROOF $46273.00 FEES LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. b. All roofing projects require an In-Progress Inspection. c. Sheathing installation and replacement guidelines per APA. d. Underlayment must conform to FBC-R Table 905.1.1 e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 11/17/2021 PERMIT NUMBER ROOF21-0087 ISSUED: 11/17/2021 EXPIRES: 5/16/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING PERMIT 455-0000-322-1000 0 $285.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $142.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $7.16 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.78 TOTAL: $489.44 2 of 2Issued Date: 11/17/2021 PERMIT NUMBER ROOF21-0087 ISSUED: 11/17/2021 EXPIRES: 5/16/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $489.44 ROOF21-0087 Address: 962 OCEAN BLVD APN: 170343 0100 $489.44 BLDG SUBSEQUENT PLAN REVIEW FEES $50.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BUILDING $285.00 BUILDING PERMIT 455-0000-322-1000 0 $285.00 BUILDING PLAN REVIEW $142.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $142.50 STATE SURCHARGES $11.94 STATE DBPR SURCHARGE 455-0000-208-0700 0 $7.16 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.78 TOTAL FEES PAID BY RECEIPT: R18066 $489.44 Printed: Wednesday, November 17, 2021 11:42 AM Date Paid: Wednesday, November 17, 2021 Paid By: RELIANT ROOFING INC Pay Method: CREDIT CARD 547089045 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R18066 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION ROOF21-0087 Page 1 of 4 Updated 10/17/18 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) *Project Address: _________________________________________________________________________ Permit #: ___________________________ *Owner/Project Name: _______________________________________________________________________________________________________ As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4. Garage Roll-Up 5. Automatic 6. Other B. WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Page 2 of 4 Updated 10/17/18 Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other Page 4 of 4 Updated 10/17/18 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name (Print Name):_________________________________ *Contractor Signature: ___________________________________________ *Company Name: __________________________________________________________________________________________________________ *Mailing Address: __________________________________________________________________________________________________________ *City: _______________________________________________ *State: ______________________ *Zip Code: _______________________________ *Telephone Number: ___________________________________ *E-mail Address: _______________________________________________________ Cell Phone Number: _____________________________________ Fax Number: _________________________________________________________ Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 (904) 247-5800 BUILDING REVIEW COMMENTS Date: 11/8/2021 Permit #: ROOF21-0087 Site Address: 962 OCEAN BLVD Review Status: Denied RE#: 170343 0100 Applicant: RELIANT ROOFING INC Property Owner: HALVORSEN JOSEF DANIEL Email: AMANDA@reliantroofing.com Email: DHALVORSEN@BOEMORTGAGE.COM Phone: 9047123111 9047123111 Phone: 9047073669 9043863295 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. All non-shingled roofing systems go through plan review in Atlantic Beach. Please submit the manufacturer’s installation instructions and the Evaluation Report for the FL# submitted for the TPO roof system. 2. Please only submit the pages that pertain to the site specific installation process for this job. High light the information on those pages. 3. Please don’t submit the whole entire package of the evaluation report (90 some pages). Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 247-5844 Email:mjones@coab.us Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with “clouding”. The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings. The original sheets must be clearly marked “VOID” but are to be left within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. 800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com Overview InsulBase is a rigid-roof insulation panel composed of a closed-cell polyisocyanurate foam core bonded on each side to glass-reinforced felt (GRF). Features and Benefi ts »InsulBase polyiso insulation provides the highest R-value per inch of commercially available insulation products »Environmentally friendly construction with 0% ozone-depleting components and CFC free »Approved for direct application to steel decks Panel Characteristics »Available in 4' x 4' (1220 mm x 1220 mm) and 4' x 8' (1220 mm x 2440 mm) panels in thickness of ½" (13 mm) to 4.5" (115 mm) Applications »Single-Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered) Installation Ballasted Single-Ply Systems Each InsulBase panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifi cations. Mechanically Attached Single-Ply Systems InsulBase panels must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifi cations. Fully Adhered Single-Ply Systems InsulBase panels must be secured to the roof deck with fasteners and plates (appropriate to deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifi cations. InsulBase 4' x 8' panels can be secured to the roof deck with Carlisle’s FAST® Adhesive, either full coverage or bead spacing. InsulBase 4' x 4' panels may be adhered to prepared concrete deck with a full mopping of Type III or IV asphalt. Review Carlisle specifi cations and details for complete installation information. Thickness (inches) Thickness (MM) LTTR R-value Flute Spanability 22.8130.50 5⁄8" 25.7251.00 5⁄8" 48.6381.50 3⁄8" 411.4512.00 3⁄8" 414.4642.50 3⁄8" 417.4763.00 3⁄8" 420.5893.50 3⁄8" 423.61024.00 3⁄8" 426.81144.50 3⁄8" EXPERIENCE THE CARLISLE DIFFERENCE InsulBase Polyiso Thermal Values ONE layer of 4' X 8' boards R-20: 3.5" ISO to be used EXPERIENCE THE CARLISLE DIFFERENCE 800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com 12.04.18 © 2018 Carlisle. REPRINT CODE: 600491 - “InsulBase Polyiso Product Data Sheet” Carlisle, SecurShield, InsulBase and FAST are trademarks of Carlisle. Codes and Compliances »ASTM C1289, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi) »International Building Code (IBC) Section 2603 »UL Standard 790, 263 and 1256: Component of Class A Roof Systems (refer to UL Roof Materials’ system directory) »FM® Standards 4450/4470: Class 1 approval for steel roof-deck constructions (refer to FM RoofNavSM) »California Code of Regulations, Title 24, Insulation Quality Standard License #TI-1418 »Third-party certifi cation with the PIMA Quality Mark for Long-Term Thermal Resistance (LTTR) values »CAN/ULC S704, Type 2 & 3, Class 2 »Florida Building Code Approval Precautions Insulation must be protected from open fl ame and kept dry at all times. Install only as much insulation as can be covered the same day by completed roof-covering material. Protect installed product from excessive foot traffi c. Carlisle will not be responsible for specifi c building and roof design by others, for defi ciencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling. Technical specifi cations shown in this literature are intended to be used as general guidelines only and are subject to change without notice. Call Carlisle for more specifi c details, or refer to PIMA Technical Bulletin No. 109: Storage & Handling Recommendations for Polyiso Roof Insulation. Typical Properties and Characteristics (ASTM C1289) Physical Property Test Method Value Compressive Strength ASTM D1621 20 psi* minimum (138 kPa, Grade 2) Dimensional Stability ASTM D2126 2% linear change (7 days) Moisture Vapor Permeance ASTM E96 <1 perm (57.5 ng/(Pa•s•m²)) Water Absorption C1763 <1% volume Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not refl ect the specifi cation range for any particular property of this product. *Also available in 25 psi minimum, Grade 3 Foamed plastic as roof deck construction material with resistance to an internal fi re exposure only for use in construction no.(s) 120 and 123. See UL Directory of Products Certifi ed for Canada and UL Roofi ng Materials and Systems Directory. 99DL. 800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Overview InsulBase Tapered is a sloped rigid roof insulation panel composed of a closed cell polyisocyanurate foam core bonded during the manufacturing process to fi ber reinforced paper facers. Tapered systems are designed to promote positive drainage and prevent ponding water. Contact Carlisle’s Tapered Systems Group for design assistance. Features and Benefi ts »InsulBase tapered polyiso insulation provides the highest R-value per inch of commercially available insulation products. »Environmentally friendly construction with 0% ozone depleting components and CFC free. »Approved for direct application to steel decks. Panel Characteristics »Available in 4' x 4' (1220 mm x 1220 mm) in thickness of ½" (12 mm) minimum to 4.5" (115 mm) maximum in a single layer »Available slopes are 1⁄16" (2 mm), 1⁄8" (3 mm), 3⁄16" (5 mm), ¼" (6 mm), 3⁄8" (10 mm) and ½" (12 mm) per foot »Available in two grades of compressive strengths per ASTM C1289, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi) Applications »Constructions requiring FM Class 1 and UL Class A ratings »Single-Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered) Installation Ballasted Single-Ply Systems Each InsulBase Tapered panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle’s specifi cations. Standard Panel Profi les ¼" Slope 1.5" 3.5" 7.5"5.5"0.5" 2.5" 4.5" 6.5" 8.5" X X X X Y Y Y Y 1/4" Slope Reference Fill Below 2.0" ISO 2.0" ISO 2.0" ISO 6.5" 10.5"2.5"0.5" 4.5" 8.5" 12.5" 2.0" ISO 2.0" ISO 2.0" ISO 2.0" ISO 2.0" Q QQ1 Q Q Q Q Q Q2 Q3 Q4 Q5 1/2" S l o p e Reference Fill Below ½" Slope 0.5"1.0" 2.0" 3.0" 4.0" 5.0" 6.0" 8.0"7.0"1.5" 2.5" 3.5" 4.5" 5.5" 6.5" 7.5" 8.5" ABC2.0" ISO 2.0" ISO 2.0" ISO 1/8" Slope Reference Fill Below 1⁄8" Slope A BC A BC A BC Extended Panel Profi les AA AA 0.5"1.0" 2.0" 3.0" 4.0" 5.0" 6.0" 8.0"7.0"1.5" 2.5" 3.5" 4.5" 5.5" 6.5" 7.5" 8.5" AA AA1 A A A A1 B B B B1 C C C C1 4.0" ISO D D D D1 E E E E1 F F F F1 FF FF FF FF1 1/8" Slope Reference Fill Below 1⁄8" Slope 1.5" 3.5" 7.5"5.5"0.5" 2.5" 4.5" 6.5" 8.5" X YZZZ 4.0" ISO X X X1 Y Y Y1 Z Z Z1 ZZ ZZ ZZ1 1/4" Slope Reference Fill Below ¼" Slope 6.5"2.5"0.5" 4.5" 8.5" 4.0" ISO Q Q QQ QQ Q Q1 QQ QQ1 1/2" S l o p e Fill Below ½" Slope AA AA AA AA EXPERIENCE THE CARLISLE DIFFERENCE 800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com 12.20.16 © 2013 Carlisle. REPRINT CODE: 603256 - “InsulBase Tapered Polyiso Product Data Sheet” Carlisle, InsulBase, StormBase, SecurShield and FAST are trademarks of Carlisle. Mechanically Attached & Fully Adhered Single-Ply Systems Each InsulBase Tapered panel must be secured to the roof deck with fasteners and plates (appropriate to deck type). Butt edges and stagger joints of adjacent panels.Install the roof membrane according to Carlisle’s specifi cations. For fully adhered single-ply, InsulBase Tapered 4' x 8' panels can be secured to the roof deck with Carlisle’s FAST® Adhesive, either full coverage or bead spacing of no less than 6" on center. Review Carlisle specifi cations and details for complete installation information. InsulBase Tapered Codes and Compliances »ASTM C1289, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi) »International Building Code (IBC) Section 2603 NOTE: Please be aware the Federal Specifi cation HH-I-1972/GEN has been replaced. Underwriters Laboratories, Inc. »Component of Class A Roof Systems (UL 790) »Hourly Rated P series roof assemblies (UL 263) P 225, 230, 259, 302, 303, 508, 510, 514, 519, 701, 710, 713, 717, 718, 719, 720, 722, 723, 727, 728, 729, 730, 732, 734, 735, 739, 741, 742, 743, 819, 824, 827, 828 »Insulated metal deck assemblies - (UL 1256) nos. 120, 123, 292 »InsulBase Tapered classifi ed by ULC Factory Mutual Research »FM Class 1 approval for steel roof-deck constructions, (FM 4450) »FM 4470 (Subject to the conditions of approval described in Roofnav.com) »FLORIDA BUILDING CODE APPROVAL FL#1296 »MIAMI-DADE COUNTY, FLORIDA NOA NO: 04-1018.01 Precautions Insulation must be protected from open fl ame and kept dry at all times. Install only as much insulation as can be covered the same day by completed roof covering material. Protect installed product from excessive foot traffi c. Carlisle will not be responsible for specifi c building and roof design by others, for defi ciencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling. Technical specifi cations shown in this literature are intended to be used as general guidelines only and are subject to change without notice. Call Carlisle for more specifi c details, or refer to PIMA Technical Bulletin No. 109: Storage & Handling Recommendations for Polyiso Roof Insulation. Typical Properties and Characteristics Physical Property Test Method Value Compressive Strength ASTM D1621 ASTM 1289 20 psi* minimum (138 kPa, Grade 2) Dimensional Stability ASTM D2126 2% linear change (7 days) Moisture Vapor Transmission ASTM E96 12.10 <1 perm (57.5 ng/(Pa•s•m²)) Water Absorption ASTM C209 <1% volume Service Temperature -100°F to 250°F (-73°C to 122°C) Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not refl ect the specifi cation range for any particular property of this product. Foamed plastic as roof deck construction material with resistance to an internal fi re exposure only for use in construction no.(s) 120 and 123. See UL Directory of Products Certifi ed for Canada and UL Roofi ng Materials and Systems Directory. 99DL. Other Polyiso Products by Carlisle »Flat and Tapered SecurShield™ – Polyiso bonded to coated glass facers »Flat Polyiso bonded to fi ber-reinforced paper facers »HP-F – Polyiso bonded to foil »StormBase® – Polyiso bonded to Oriented Strand Board »SecurShield HD – ½" Polyiso coverboard, 100 PSI »SecurShield HD Composite – Polyiso bonded on-line to ½" SecurShield HD Coverboard »SecurShield HD Plus – ½" Polyiso coverboard, 100 PSI – FM 1-90 with reduced fastening »SecurShield CD – 1" Class A Polyiso on a combustible deck EXPERIENCE THE CARLISLE DIFFERENCE TPO (Thermoplastic) Rooftop Guide/Inspection Checklist800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 Fax: 717-245-7053 | www.carlislesyntec.com Carlisle, Piranha, SecurTAPE and Elastoform Flashing are trademarks of Carlisle. 08.16.16 © 2016 Carlisle. REPRINT CODE: 608956 - “TPO (Thermoplastic) Rooftop Guide/Inspection Checklist” Guide for Inspecting Your System This guide will illustrate the minimum requirements of a roof inspection and provide a basic understanding of some common details. Below is a simple roof drawing with penetrations included. It shows the path followed by Carlisle Field Service Representatives (FSRs) when they inspect a roof for warranty. Step 1: Inspect the perimeter. Update the roof plan to show the location of all curbs, penetrations, drains, etc. Focus on securement and termination. Mark defi ciencies on the roof plan as they are found. Step 2: Inspect all seams on the roof level. Focus on plate placement and proper seaming. Step 3: Inspect all curbs, penetrations, drains, etc. Focus on one detail at a time, confi rming proper securement, termination, and fl ashing minimums. Step 4: Finally, walk across the roof, update areas in need of repair, and perform a general check of the system. – Roof Hatch – Curb – Pipe – Pourable Sealer Pocket Quick Reference Note: This drawing is for your records. Applicators should complete all repairs by the end of each work day. When the roof has multiple levels, inspect one level at a time. For larger roof levels, break into smaller sections to eliminate confusion. NOTE: USE TPO PRIMER WITH ALL PRESSURE-SENSITIVE (PS) PRODUCTS. Heat Welding Procedures: Temperature settings for automatic welder: TPO = 1004°F All welds must be a minimum of 1½" wide, regardless of warranty duration. Minimum requirements for test welds: Perform a test weld at the start of work each morning and afternoon by using like material over the same substrate. Carlisle does not require the use of destructive testing. Once cooled, peel the test sample apart to examine delamination of the membrane from the scrim reinforcement. Welding Troubleshooting Checklist: • Temperature and/or speed of welder • Outside temperature (humidity and time of day) • Heat transfer over insulation plates • Cold welds/voids can be found where seams cross over plates • Cord size and distance from power source • Generator size and wattage • Minimum 6500-watt generator for 1 automatic welder • Minimum 3000-watt generator for 2 hand welders • Regular service/maintenance for welder • Cleanliness of membrane • Proper cleaning materials/rags • Weathered Membrane Cleaner for TPO membrane • Cleanliness of automatic welder/hand welder nozzle • Check all start and stop points thoroughly All seams must be probed prior to fi nal roof inspection. Voids in the membrane must be repaired by the end of each work day. Please consult Carlisle’s Specifi cation Supplement (section T-01-11) for more information about welding procedures, generator usage, and general troubleshooting. – Scupper – Drain – Sleeper IMPORTANT INFORMATION: If you need assistance, it’s only one call away. Local FSR phone number: Additional FSR phone number(s): Sales Representative phone number: Technical Sales Representative phone number: Distributor phone number(s): As a reminder, this guide is meant to help with details commonly seen in the fi eld. Not all details are included in this guide. Carlisle applicators are encouraged to call with any questions. For assistance, please call 1-800-479-6832 and ask for the Technical Warranty Services Department. Scan the QR Code to view the Inspection Quick Reference Video 6 U-1A SecurSeal Drip Edge 1. Is wood nailer wider than metal fl ange? 2. Is wood nailer fl ush with insulation? 3. A continuous cleat and the metal must be fastened 6" OC using ring shank nails. a. Installed according to SMACNA ES-1 requirements. 4. Deck fl ange must be completely covered by TPO PS Cover Strip with a minimum of 2" coverage past nail heads. • Apply TPO PS Coverstrip using TPO Primer or Low-VOC Primer. • Wood nailer must be securely anchored. • When using metal by others, the metal fl ange must be fastened so it does not bow prior to overlaying. U-2A/MF- 2A Membrane Splice 1. Are all seams probed? Are all welds a minimum of 1½" wide? 2. If reinforced edging is exposed, is 1/8" bead of TPO Cut-Edge Sealant present? 3. For 60-mil and thicker membranes, are TPO T-Joint Covers present at fi eld splice intersections? 4. On mechanically fastened systems, are Piranha™ Plates fastened minimum 12" OC within the fi eld splice? U-5A Curb Flashing Thermoplastic 1. Is 1½" hot air weld past plates and fasteners present? 2. Is membrane terminated properly at the top of the curb? a. Is counter-fl ashing used? If so, was it fastened with neoprene washers? b. Are fasteners present underneath metal counter-fl ashing? c. Is Water Cut-Off Mastic present? 3. Membrane securement at inside angle changes? 4. Are outside corners complete? 5. On 60-mil and thicker membranes, have factory-fabricated T-Joint Covers been installed? 6. If Termination Bar is used, follow U-9D Details. U-6A Drain Details 1. Are all drain bolts or clamps are in place to provide constant compression? 2. Hole in membrane must be larger than drain hole itself, minimum ½" from inside the drain ring. 3. Is Water Cut-Off Mastic present between the cleaned drain bowl and the membrane? 4. If seams are present in drain: a. Entire splice overlap at drain base must be hot air welded. 5. Drain ring must not be broken/cracked (must be replaced if found this way). U-8 Pipes/Single Penetrations Note: Temperature of pipes must not exceed 160°F. Field-fabricated Hot Stack must be installed per Detail U-8E. Pre-molded Pipe Flashing 1. Is it on a fl at surface (fl anges cannot be overlapped)? 2. Is cut in pipe boot above rib? 3. Are Water Cut-Off Mastic and clamping ring present at top of boot? Field-fabricated Pipe Flashing 1. Are two wraps present? a. Base wrap goes up pipe ½" minimum? b. Top wrap overlaps base wrap 1" with a 1½" minimum splice on the vertical overlap? c. Are Water Cut-Off Mastic and clamping ring present at top of fi eld-fabrication? d. Fully adhered systems: Securement is needed at any pipes greater than 18" in diameter. Mechanically fastened systems: securement is always required. U-9 Termination Bars 1. If warranty duration is 15 years or longer, Termination Bar must be present. a. For warranties longer than 20 years, counter-fl ashing and Termination Bar must be used. 2. Is Water Cut-Off Mastic present? 3. Is Universal Single-Ply Sealant/sealant by others present at top of Termination Bar? a. If counter-fl ashing is used, Universal Single-Ply Sealant/ sealant by others is required at top edge of metal fl ashing: not on top of Termination Bar. 4. Termination Bar not bent? 5. Fastening of bar shall never exceed 12" OC and must always be suffi ciently fastened to keep constant compression on Water Cut- Off Mastic. 6. Do not wrap Termination Bar around corners. Apply on hard, smooth surfaces only: not for use on exposed wood. a. See Detail U-9E for additional requirements if Termination Bar is used at tilt-up panel joints. b. Water Cut-Off Mastic must be installed at approximately 10’ per tube. U-12 Parapet/Curb Angle Change 1. Is securement present? Note: TPO Primer is required to mate membrane to PS RUSS, bonding adhesive is not acceptable. a. Appropriate fastening rate for required warranty? No more than 12" OC. b. 6" OC for warranty wind speeds greater than 90 mph. 2. Verify all fl ashings are properly adhered. 3. When seam is present at angle change, there must be a 1½" weld. a. If 1½" weld is not achieved, overlay using TPO Non- Reinforced Flashing with a minimum 1½" splice in all directions around the splice. 4. How is membrane terminated? a. See Detail U-9. U-13 Tie-ins to Existing Roofi ng System 1. Is membrane securement present? 2. If the deck slopes toward the new roofi ng system, refer to tie-in details: Concrete Deck Termination or Weep Holes Steel Deck. 3. For built-up roof tie-ins: a. Cold Tie-in – PS Elastoform Flashing® used with Two- Part Pourable Sealer. b. Hot Tie-in – multiple layers of felt and asphalt must be used. Refer to pg. 50 of the Field Guide for exact steps. See Detail U-13B. 4. Tie-ins for existing membrane/EPDM or TPO U-13C, D, and E: a. PS Cured Coverstrip or fi eld membrane in conjunction with PS SecurTAPE™. 5. Shingle roof tie-ins: Detail U-13F (extend above anticipated slush line). 6. When tying in to PVC, a complete isolation of the system must be built and separation walls must be constructed. U-15 Inside/Outside Corner With or Without PS RUSS 1. Is membrane securement present at angle change? 2. Are plates and fasteners 6"-9" away from Inside/Outside Corner? 3. Are plates and fasteners minimum 12" OC? Note: 6" OC must be used when warranty wind speed is greater than 90 mph. See U-12 Details. 4. Pig ear fold in Inside Corner: a. Fold on vertical wall and shedding water? 1½" weld achieved? 5. When fl ashing Inside or Outside Corners, use one of the following: a. TPO Inside Corners or TPO Outside Corners. Please note: TPO accessory corners are not universal. b. Or, when cutting your own 6" x 6" TPO Non-Reinforced Flashing: i. Flashing must be formed before application of Inside or Outside Corners. See Details U-15 B and F. U-16 Molded Sealant Pockets 1. For use on multiple hard-to-fl ash penetrations. Pipe clusters must have a minimum of 1" clearance between penetrations. 2. Entire area inside Molded Sealant Pocket, as well as all penetrations, must be primed using TPO Primer or Low-VOC Primer. 3. Carlisle One-Part Pourable Sealer must be used: fi ller by others is not allowed. Is Pourable Sealer at least 2" deep? 4. 1½" weld present on deck fl ange? 5. Securement is required on mechanically fastened systems: Not required on fully adhered systems. a. In fully adhered systems, pockets larger than 18" in diameter must have plates and fasteners. U-18 Metal Scupper 1. Metal scupper box must have a continuous fl ange with rounded corners. 2. Is wood nailer present underneath metal? 3. Is Water Cut-Off Mastic present underneath metal and on top of membrane? 4. Is Cut-Edge Sealant present? 5. Sealant by others is needed on outside of scupper where the scupper meets the outside wall. U-24 Sleepers/Wood Blocking 1. Are slip sheets present underneath to prevent damage to new membrane? Check usage of Walkway Rolls. 1. Present at all fi xed access points, HVAC units that are regularly serviced, and concentrated walk areas? U-27 Insulation Fastening 1. Is insulation fastening in accordance with current specifi cations and details? 2. Has proper fastener penetration been achieved? 3. Reduced fastening patterns are approved on 22-gauge or heavier steel, concrete, minimum 1½" wood, and ¾" plywood decks only. Common Details 3 7 4 6 5 2 3 A 6 54 U-1A SecurSeal Drip Edge Fascia B B U-12A Parapet Flashing U-16A Molded Sealant Pocket U-5A Curb Flashing Sure-Weld TPO Membrane Carlisle's Sure-Weld TPO is a premium, heat-weldable, single-ply thermoplastic polyolefi n membrane, engineered to provide outstanding long-term performance in new roof construction and re-roofi ng applications. All Sure-Weld TPO membranes utilize the patented OctaGuard XT™ weathering package technology, which is able to withstand extreme durability testing intended to stimulate exposure to several climates. Sure-Weld TPO Accessories Carlisle also offers over a dozen prefabricated, in-stock, standard-order accessories, and countless custom-order accessories. All carry a CFA (Certifi ed Fabricated Accessory) stamp of approval, so you know they are manufactured to the highest standards. Every Carlisle CFA-approved accessory saves time and money during installation. Installation Carlisle’s Sure-Weld TPO Fully Adhered Roofi ng System utilizes white, gray, or tan membranes in standard reinforced 45- or 60-mil thicknesses or 80-mil-thick reinforced Sure-Weld EXTRA membranes. Insulation, where required, is secured to an acceptable roof deck. Sure- Weld TPO membrane sheets are fully adhered to the insulation or substrate with Carlisle’s Sure-Weld TPO Bonding Adhesive. Adjoining sheets are hot-air welded. The above information represents a typical Carlisle Sure-Weld TPO Fully Adhered Roofi ng System. Refer to Carlisle’s published specifi cations and details for more complete information. Membrane and System Strengths »Sure-Weld TPO membrane is available in white, gray, and tan, in 6', 8', 10', and 12' widths »Provides superior puncture and hail resistance » White and tan Sure-Weld TPO refl ectivity values exceed industry standards; they both are ENERGY STAR* qualifi ed »Puncture warranty available with 60- and 80-mil Sure-Weld EXTRA membrane »Membranes are eco-friendly as they do not contain chlorine or plasticizers System Codes » UL Class A, B, and Universal Slope ratings are available over any deck type »FM uplift values of up to 150 psf can be achieved For code specifi cs, refer to Carlisle’s Sure-Weld Code Approval Guide. Quality Assurance Carlisle Authorized Roofi ng Contractors have received training to install Carlisle’s Sure-Weld TPO Roofi ng Systems. Inspection Upon installation completion, and prior to the issuance of a membrane system warranty, an inspection will be conducted by a Carlisle Field Service Representative. Warranty Consult your roofi ng contractor or Carlisle Manufacturer’s Representative/Distributor for associated warranty charges. This system, properly installed and inspected on a commercial project, may receive: »A 10-year Total System or 15-year Golden Seal Warranty when all materials used for the roofi ng installation are manufactured or marketed by Carlisle »A 10-year Refl ectivity Warranty (based on ENERGY STAR criteria) with white membrane »A 20-year Golden Seal Warranty with 60-mil Sure-Weld EXTRA membranes »A 25- or 30-year Golden Seal Warranty with 80-mil Sure-Weld EXTRA membrane »Higher wind speed warranties (up to 120 mph peak gust wind speed) available upon review by Carlisle For more specifi cs or for International warranty programs, contact Carlisle. EXPERIENCE THE CARLISLE DIFFERENCE Fully Adhered Roofi ng Systems 800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com 12.04.18 © 2018 Carlisle. REPRINT CODE: 600337 - “Sure-Weld TPO Fully Adhered System Sheet” Carlisle, Sure-Weld, OctaGuard XT and FAST are trademarks of Carlisle. ENERGY STAR is a registered trademark owned by the U.S. Government. *ENERGY STAR qualifi cation is only valid in the U.S. *ENERGY STAR recommends that using the Roof Savings Calculator (rsc.ornl.gov), which factors in both heating and cooling costs, to determine whether a cool roof will be an energy effi cient choice for your geographic climate and building type.