Loading...
1232 Main St ROOF21-0090 8 Squares Metal Roof ReplacementOWNER:ADDRESS:CITY:STATE:ZIP: SMITH KEVIN P 1232 MAIN ST ATLANTIC BEACH FL 32233-2643 COMPANY:ADDRESS:CITY:STATE:ZIP: RELIANT ROOFING INC 8000 Belfort Parkway Suite 200 Jacksonville FL 32256 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171052 0070 ATLANTIC BEACH SEC H JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1232 MAIN ST ROOF NON SHINGLE 8 squares metal roof replacement $12823.00 FEES LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a. The roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved. b. All roofing projects require an In-Progress Inspection. c. Sheathing installation and replacement guidelines per APA. d. Underlayment must conform to FBC-R Table 905.1.1 e. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 12/1/2021 PERMIT NUMBER ROOF21-0090 ISSUED: 12/1/2021 EXPIRES: 5/30/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BLDG 3RD PLAN REVIEW FEE 455-0000-322-1006 0 $75.00 BLDG 4TH PLAN REVIEW FEE 455-0000-322-1006 0 $150.00 BUILDING PERMIT 455-0000-322-1000 0 $115.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $57.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.71 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.48 TOTAL: $458.69 2 of 2Issued Date: 12/1/2021 PERMIT NUMBER ROOF21-0090 ISSUED: 12/1/2021 EXPIRES: 5/30/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $401.19 ROOF21-0090 Address: 1232 MAIN ST APN: 171052 0070 $401.19 BLDG SUBSEQUENT PLAN REVIEW FEES $275.00 BLDG 2ND PLAN REVIEW FEE 455-0000-322-1006 0 $50.00 BLDG 3RD PLAN REVIEW FEE 455-0000-322-1006 0 $75.00 BLDG 4TH PLAN REVIEW FEE 455-0000-322-1006 0 $150.00 BUILDING $115.00 BUILDING PERMIT 455-0000-322-1000 0 $115.00 STATE SURCHARGES $11.19 STATE DBPR SURCHARGE 455-0000-208-0700 0 $6.71 STATE DCA SURCHARGE 455-0000-208-0600 0 $4.48 TOTAL FEES PAID BY RECEIPT: R18161 $401.19 Printed: Wednesday, December 1, 2021 10:33 AM Date Paid: Wednesday, December 01, 2021 Paid By: RELIANT ROOFING INC Pay Method: CREDIT CARD 553690676 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R18161 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION Page 1 of 4 Updated 10/17/18 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) *Project Address: _________________________________________________________________________ Permit #: ___________________________ *Owner/Project Name: _______________________________________________________________________________________________________ As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # A. EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional 4. Garage Roll-Up 5. Automatic 6. Other B. WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Page 2 of 4 Updated 10/17/18 Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # C. PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other Page 4 of 4 Updated 10/17/18 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name (Print Name):_________________________________ *Contractor Signature: ___________________________________________ *Company Name: __________________________________________________________________________________________________________ *Mailing Address: __________________________________________________________________________________________________________ *City: _______________________________________________ *State: ______________________ *Zip Code: _______________________________ *Telephone Number: ___________________________________ *E-mail Address: _______________________________________________________ Cell Phone Number: _____________________________________ Fax Number: _________________________________________________________ Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 2 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX B Approved Systems for GulfLok over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) LOK-W-4 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC 24 ga. GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-1/8 in. o.c. -96.75 LOK-W-5 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-3/16 in. o.c. Titebond Weathermaster Metal Roof Sealant applied to male rib. -116 LOK-W-6 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfLok Max. 16-inch coverage GulfLok Type 1 attachment with #10-12 x 1” Pancake Type A screws spaced 5-3/16 in. o.c. Titebond Weathermaster Metal Roof Sealant applied to male rib. -121.75 LOK-W-7 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC 26 ga., Grade 80 GulfLok Max. 16-inch coverage GulfLok Type 2 attachment with #10-12 x 1” Pancake Type A screws through clip and spaced 5-3/16 in. o.c. -161 Approved Systems for GulfSeam over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) SEAM-W- Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with clips spaced 18 in. o.c. -60 SEAM-W- Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with stainless steel clips spaced 18 in. o.c. -60 SEAM-W-1 Min. 15/32 B-C plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 24 ga. GulfSeam Max. 18-inch coverage GulfSeam Type 1 attachment with clips spaced 24 in. o.c. -69.25 SEAM-W- Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 26 ga. GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with clips spaced 6 in. o.c. -75 SEAM-W- Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC Min. 0.032” Al GulfSeam Max. 16-inch coverage GulfSeam Type 1 attachment with stainless steel clips spaced 6 in. o.c. -75 Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 6 of 6 Page 6 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. This report is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be in accordance with FBC Section 1511. Recovery versus replacement shall be evaluated in accordance with FBC Section 1511.3. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products und er this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A – Installation (5 pages) 2) APPENDIX B – Approved Roof Systems (7 pages) 3) APPENDIX C – Design Wind Loads (4 pages) This item has been digitally signed and sealed by Zachary R. Priest, PE, on 4/13/2021. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 2021.04.13 15:33:13 -04'00' A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 1 of 5 Page 1 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A INSTALLATION Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail Fasteners #9-15 HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion resistant in accordance with FBC section 1507.4.4. #9-15 HWH WoodZAC screw #10-12 Pancake Type A screw #12-11 Pancake Type A screw #12-8 HWH Woodgrip XG screw with sealing washer 1/4-14 HWH ZAC Impax Lap screw Installed at panel side lap; Shall be corrosion resistant in accordance with FBC section 1507.4.4. Clips GulfLok Clip 24 ga. in-seam clip Fixed Clip 18 ga. in-seam clip A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 2 of 5 Page 2 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A Component Product Installation Detail Clips (Cont’d) NC-33003-3 Sliding Clip 1500SC Sliding Clip 22 ga. top; 16 ga. base; in-seam clip Sealants TiteBond Weathermaster Metal Roof Sealant Shall be applied in 1/4”- 5/16” continuous beads on the male rib along the seam Fastening Details Nomenclature Attachment GulfLok Type 1 GulfLok Overlap A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 3 of 6 Page 3 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing PRODUCT DESCRIPTION GulfLok Profile: 1 in. snap lock seam; Max.16 in. coverage Description: Non-structural, snap lock standing seam roof panel with 7/8 in. slotted nail strip Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Fluropon® paint finish; Fy = min. 24 ksi; Shall conform with FBC Section 1507.4.3 GulfSeam Profile: 1 3/4 in. snap lock seam; Max. 18 in. coverage Description: Non-structural, snap lock standing seam roof panel Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032-inch ASTM B209, 3105 H24 aluminum, Optional Fluropon® paint finish; Fy = min. 21 ksi; Shall conform with FBC Section 1507.4.3 MegaLoc Profile: 2 in. mechanical seam; Max. 18 in. coverage Description: Non-structural, mechanical lock 180º standing seam roof panel Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 Permit Number: ROOF21-0090 Site Address: 1232 MAIN ST City, State Zip Code: Atlantic Beach, Fl 32233 Applied: 11/5/2021 Approved: Issued: Parent Permit: Parent Project: Applicant: <NONE> Owner: SMITH KEVIN P Contractor: <NONE> Description: 8 squares metal roof replacement Finaled: Status: RECEIVED Details: LIST OF REVIEWS SENT DATE RETURNED DATE DUE DATE TYPE CONTACT STATUS REMARKS Review Group: AUTO 11/5/2021 11/5/2021 SUBMITTAL COMPLETENESS Jennifer Johnston APPROVED Notes: received via email, uploaded as attachment 11/5/2021 11/8/2021 11/22/2021 BUILDING Building DENIED Notes: Correction Comments: 1. All non-shingled roof systems go through plan review in Atlantic Beach, FL. 2. Please submit the manufacturer’s installation instructions and the Evaluation Report for the FL# submitted for the metal roof system. Printed: Tuesday, 09 November, 2021 1 of 1 Permit Reviews City of Atlantic Beach a CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 1 of 6 Page 1 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Registry No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: GULF COAST SUPPLY & MANUFACTURING, LLC Issued April 13, 2021 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 (352) 498-7852 www.gulfcoastsupply.com Manufacturing Locations: Alachua, FL Sebring, FL Montgomery, AL Quality Assurance: Keystone Certifications, Inc. (QUA1824) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year Force Engineering & Testing (TST5328) 72-0313T-06A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 72-0198T-07A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0033T-05 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0053T-05 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07D-F UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07G-I UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0062T-07J-K UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0065T-07A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0076T-12A UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0089T-05.1 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0089T-05.2 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0102T-05 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0165T-11B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0238T-09D FM 4471 1992 Force Engineering & Testing (TST5328) 117-0238T-09E FM 4471 1992 Force Engineering & Testing (TST5328) 117-0238T-11A FM 4471 1992 Force Engineering & Testing (TST5328) 117-0248T-07A,B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0284T-09A UL 580 UL 1897 2006 2012 A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 2 of 6 Page 2 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing Entity Report No. Standard Year Force Engineering & Testing (TST5328) 117-0285T-09A UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0301T-10A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0330T-10A-B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0331T-08A UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0331T-08B UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0331T-08D UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0337T-10 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0378T-11A FM 4471 1992 Force Engineering & Testing (TST5328) 117-0378T-11B FM 4471 1992 Force Engineering & Testing (TST5328) 117-0378T-11C FM 4471 1992 Force Engineering & Testing (TST5328) 117-0407T-09 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 117-0407T-09A UL 580 UL 1897 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) B9000.01-450-18 UL 580 UL 1897 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) C0308.01-450-18 UL 580 UL 1897 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) D0818.01-450-18 UL 580 2006 Intertek- West Palm Beach (an ATI company) (TST1527) D1692.01-450-44 UL 580 UL 1897 ASTM E 8 2006 2012 Intertek- West Palm Beach (an ATI company) (TST1527) G7287.01-450-44 UL 580 2006 PRI Construction Materials Technologies (TST5878) 1272T0005 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) 2292T0001 UL 580 UL 1897 2006 2012 PRI Construction Materials Technologies (TST5878) 2292T0002 UL 580 UL 1897 2006 2012 A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 3 of 6 Page 3 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing PRODUCT DESCRIPTION GulfLok Profile: 1 in. snap lock seam; Max.16 in. coverage Description: Non-structural, snap lock standing seam roof panel with 7/8 in. slotted nail strip Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Fluropon® paint finish; Fy = min. 24 ksi; Shall conform with FBC Section 1507.4.3 GulfSeam Profile: 1 3/4 in. snap lock seam; Max. 18 in. coverage Description: Non-structural, snap lock standing seam roof panel Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032-inch ASTM B209, 3105 H24 aluminum, Optional Fluropon® paint finish; Fy = min. 21 ksi; Shall conform with FBC Section 1507.4.3 MegaLoc Profile: 2 in. mechanical seam; Max. 18 in. coverage Description: Non-structural, mechanical lock 180º standing seam roof panel Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 4 of 6 Page 4 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing VersaLoc Profile: 1.5 in. mechanical seam; Max. 18 in. coverage Description: Non-structural, mechanical lock 180º standing seam roof panel Material: Min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 5V Crimp Profile: 7/16 in. ribs at 12 in. o.c.; 24 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3 Min. 0.032 in. ASTM B209, 3105 H24 aluminum; Optional Fluropon® paint finish; Fy = min. 25 ksi; Shall conform with FBC Section 1507.4.3 GulfPBR Profile: 1 1/4 in. ribs at 12 in. o.c.; 36 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 5 of 6 Page 5 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing GulfRib Profile: 3/4 in. ribs at 9 in. o.c.; 36 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 29 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3 GulfWave Profile: 3/4 in. corrugation; 29 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Optional Fluropon® paint finish; Fy = min. 80 ksi; Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 6 of 6 Page 6 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. This report is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be in accordance with FBC Section 1511. Recovery versus replacement shall be evaluated in accordance with FBC Section 1511.3. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products und er this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A – Installation (5 pages) 2) APPENDIX B – Approved Roof Systems (7 pages) 3) APPENDIX C – Design Wind Loads (4 pages) This item has been digitally signed and sealed by Zachary R. Priest, PE, on 4/13/2021. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 2021.04.13 15:33:13 -04'00' A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 1 of 5 Page 1 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A INSTALLATION Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail Fasteners #9-15 HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion resistant in accordance with FBC section 1507.4.4. #9-15 HWH WoodZAC screw #10-12 Pancake Type A screw #12-11 Pancake Type A screw #12-8 HWH Woodgrip XG screw with sealing washer 1/4-14 HWH ZAC Impax Lap screw Installed at panel side lap; Shall be corrosion resistant in accordance with FBC section 1507.4.4. Clips GulfLok Clip 24 ga. in-seam clip Fixed Clip 18 ga. in-seam clip A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 2 of 5 Page 2 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A Component Product Installation Detail Clips (Cont’d) NC-33003-3 Sliding Clip 1500SC Sliding Clip 22 ga. top; 16 ga. base; in-seam clip Sealants TiteBond Weathermaster Metal Roof Sealant Shall be applied in 1/4”- 5/16” continuous beads on the male rib along the seam Fastening Details Nomenclature Attachment GulfLok Type 1 GulfLok Overlap A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 3 of 5 Page 3 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A Fastening Details Nomenclature Attachment GulfLok Type 2 GulfSeam Type 1 MegaLoc Type 1 VersaLoc Type 1 5V Type 1 5V Type 2 A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 4 of 5 Page 4 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A Fastening Details Nomenclature Attachment 5V Type 3 GulfPBR Type 1 GulfPBR Type 2 GulfRib Type 1 GulfRib Type 2 A CREEK Technical Services, LLC GCS20002.1a FL33818-R1 Page 5 of 5 Page 5 of 23 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GULF COAST SUPPLY & MANUFACTURING, LLC Metal Roofing APPENDIX A Fastening Details Nomenclature Attachment GulfRib Type 3 GulfRib Type 4 GulfWave Type 1 Copyright ©2019 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 11/19 • Doc# Polystick TU MAX POLYSTICK® TU MAX PREMIUM SELF-ADHERED HIGH TEMPERATURE ROOF UNDERLAYMENT www.polyglass.us PRODUCT DESCRIPTION Polystick TU MAX is a homogeneous rubberized asphalt waterproofing membrane designed specifically for use as an underlayment in adhesive foam or mechanically fastened roof tile applications. TU Max features a superior polyester reinforced surface fabric which provides for exceptional durability, UV exposure rating, and proven foam set adhesion. Additionally, the surfacing has been tested to comply with all minimum requirements for roof tile applications including skid resistance, tile stackability and high temperature ratings. Polystick TU MAX is designed for use in new construction and re-roof applications where tiles may be stacked on rooftops for extended periods of time. Polystick TU MAX is rated for 180 day exposure. Polystick TU MAX underlayment is manufactured using patented ADESO® Self-Adhered Technology. This membrane meets or exceeds applicable ASTM and TAS testing requirements for steep slope roofing products. Polystick TU MAX features patented SEALLap®, a factory applied adhesive treatment at the membrane overlap, which provides for improved ease of application, as well as improved immediate and long term performance. TYPICAL APPLICATIONS • Multi-purpose steep slope underlayment, specially designed for tile applications though suitable as a high performance underlayment for most steep roof coverings • Designed as effective reinforcement for perimeter and flashing details • For use in both adhesive set and mechanically fastened roof tile applications FEATURES AND BENEFITS • Proprietary self-adhered technology for exceptional performance • Polyester reinforced surface engineered for superior slip resistance • Approved exposure rating to 180 days (or as limited by local building codes) TECHNICAL DESCRIPTION* Physical Properties ASTM Method ASTM Value Maximum Load, Longitudinal and Transverse, min, kN/m [lbf/in.]D5147 4.4 [25] Elongation at break, min of modified bitumen portion [%]D5147 10 Tear Resistance, Longitudinal and Transverse, min, N [lbf]D5147 89 [20] Moisture Vapor Permeability, max, perms E96 0.1 Adhesion to Plywood min at 40ºF, lbf/ft width D1970 2.0 Adhesion to Plywood min at 75ºF, lbf/ft width D1970 12.0 Sealability around nail D1970 pass Waterproof integrity after low temp flexibility D1970 pass Waterproof integrity of lap seam D1970 pass Slip Resistance D1970 pass *The properties in this table are “as manufactured” unless otherwise noted PRODUCT DATA** Coverage (Approx) ....200 sq ft (18.5 m2) Weight (Approx) ...............70 lbs (32 kg) Thickness (Nominal) .......60 mils (1.5 mm) Roll Size .......65'8" × 39 3⁄8" (20 m × 1 m) Rolls/Pallet .......................................25 **All values are nominal at time of manufacturing APPLICABLE STANDARDS • ASTM D1970, ASTM D5147 • ICC ESR-1697 • Florida Building Code • Miami-Dade County Approved • Texas Department of Insurance TM PRODUCT CODES • PSTUMAXQ Copyright ©2019 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 11/19 • Doc# Polystick TU MAX POLYSTICK® TU MAX PREMIUM SELF-ADHERED HIGH TEMPERATURE ROOF UNDERLAYMENT www.polyglass.us APPLICATION INSTRUCTIONS • Polystick TU MAX may be directly to the roof deck. • Do not apply to shingles or other finished roof coverings. • Apply only when the weather is dry and material interface temperatures (air, roof deck, membrane) are 40° F and rising. • Always start at the lowest point of the roof deck where possible. • Cut the Polystick TU MAX to a suitable, workable length prior to placement. • Lay the material flat in place, starting at the lowest point. Overlap seams 3" minimum and endlaps 6" minimum. • Peel half of the backing off the roll and apply firm, even pressure from the center to the outer edges. • Remove the backing from the remaining half of the roll and apply pressure. • Always ensure that Polystick TU MAX is applied over the area to cover the highest point of “ice damming”. • Be sure to follow all local building code recommendations and requirements with regards to the width of ice dam materials. • If full roof coverage application is desired, proper venting of the structure is required. Consult a design professional for proper venting requirements. • In steep slope applications(i.e. 3:12 slope or higher) where backnailing will be required, be sure that all nails are covered by the overlapping next sheet. • Polystick TU MAX must be covered within 180 days of installation unless otherwise limited by local authorities. • Use PolyPlus® 50 or PG 500 to seal all end laps, hip and ridge details, and any adhesive compound splices, patches or details. • Apply a bed of cement on any metals, vents, stacks, chimneys, and other roof accessories. • Use as any repair membrane to the underlayment prior to application of the final roof covering. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Waco, TX • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.us General Line: (888) 410-1375 (954) 233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 802-8017 Questions? technical@polyglass.com Product Disclaimer: Unless other wise incorporated into or part of a supplemental manufacturer’s warranty, Polyglass warrants its product(s) against manufacturing defects in its product that directly results in leakage for a period of 1 year. Refer to safety data sheet (SDS) for specific data and handling of our products. All data furnished refers to standard production and is given in good faith within the applicable manufacturing and testing tolerances. Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time without prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products under conditions beyond its own control. For most current product data and warranty information, visit www.polyglass.us