Loading...
2139 Seminole Rd ROOF21-0098 MetalOWNER:ADDRESS:CITY:STATE:ZIP: Camille Adams 2139 SEMINOLE RD ATLANTIC BEACH FL 32233-5921 COMPANY:ADDRESS:CITY:STATE:ZIP: HAGERTY CONSTRUCTION AND ROOFING INC 12850 WINTHROP COVE DR JACKSONVILLE FL 32224 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169515 0500 SECTION LAND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 2139 SEMINOLE RD ROOF NON SHINGLE METAL ROOF $6120.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: IN-PROGRESS INSPECTIONS ARE REQUIRED FOR EXTERIOR SIDING, WINDOW, AND DOOR INSPECTIONS, AND SHOULD BE SCHEDULED FOR THE FIRST DAY OF WORK. 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 12/29/2021 PERMIT NUMBER ROOF21-0098 ISSUED: 12/29/2021 EXPIRES: 6/27/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $85.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $42.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $131.50 2 of 2Issued Date: 12/29/2021 PERMIT NUMBER ROOF21-0098 ISSUED: 12/29/2021 EXPIRES: 6/27/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $131.50 ROOF21-0098 Address: 2139 SEMINOLE RD APN: 169515 0500 $131.50 BUILDING $85.00 BUILDING PERMIT 455-0000-322-1000 0 $85.00 BUILDING PLAN REVIEW $42.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $42.50 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R18380 $131.50 Printed: Wednesday, December 29, 2021 10:58 AM Date Paid: Wednesday, December 29, 2021 Paid By: HAGERTY CONSTRUCTION AND ROOFING INC Pay Method: CREDIT CARD 567350082 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R18380 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION R OOF21-009999 ROOF21-0098 This item has been electronically signed and sealed by James L. Buckner, P.E., on this date using a Digital Signature. Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies. 2020.10.11 21:24:38 -04'00' Specialty Structural Engineering CBUCK, Inc. – Palm Beach County, Florida Phone: (561) 491-9927 · Email: cbuck@cbuckinc.net · Website: www.cbuckinc.net Main Office: 1374 Community Drive, Jupiter, Florida 33458 CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Evaluation Report “M-Seam” Metal Roof Assembly Manufacturer: Millennium Metals, Inc. 10200 Eastport Road Jacksonville, FL 32218 (877) 358-7663 for Florida Product Approval # FL 5211.3 R8 Florida Building Code 7th Edition (2020) Per Rule 61G20-3 Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: “M-Seam” Material: Steel Panel Thickness: 26 gauge, (Minimum) Panel Width: 16” Support: Wood Deck Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Report No. 20-224-M-S6W-ER Date: 10 / 11 / 2020 Contents: Evaluation Report Pages 1 – 7 ROOF21-0098 FL #: FL 5211.3-R8 Date: 10 / 11 / 2020 Report No.: 20-224-M-S6W-ER Page 2 of 7 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Manufacturer: Millennium Metals, Inc. Product Name: “M-Seam” Product Category: Roofing Product Sub-Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System Description: “M-Seam” 26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Evaluated: Refer to Page 4 of this report for product assembly components/materials & standards: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32 (min.) or 19/32” or greater plywood, • or Wood plank (min. specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer’s recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure: (Refer to “Table A” attachment details herein) Refer to Table “A” FL #: FL 5211.3-R8 Date: 10 / 11 / 2020 Report No.: 20-224-M-S6W-ER Page 3 of 7 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Performance Standards: The product described herein has demonstrated compliance with: • UL580-06 – Test for Uplift Resistance of Roof Assemblies • UL 1897-12 – Uplift test for roof covering systems Standards Equivalency: • The UL 580-94 standard version used to test the evaluated product assembly is equivalent to UL580-06 standard version adopted by the Florida Building Code 7th Edition (2020). • The UL 1897-98 standard version used to test the evaluated product assembly is equivalent to UL1897-12 standard version adopted by the Florida Building Code 7th Edition (2020). Code Compliance: The product described herein has demonstrated compliance with the performance standards listed above as referenced in the Florida Building Code 7th Edition (2020). Evaluation Report Scope: This product evaluation is limited to compliance with the structural requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and Conditions of Use: • Scope of “Limitations and Conditions of Use” for this evaluation: This evaluation report for “Optional Statewide Approval” contains technical documentation, specifications and installation method(s) which include “Limitations and Conditions of Use” throughout the report in accordance with Rule 61G20- 3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under “Optional Statewide Approval”. • Option for application outside “Limitations and Conditions of Use” Rule 61G20-3.005(1)(e) allows engineering analysis for “project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code”. Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • All metal components and fasteners shall be corrosion resistant in accordance with applicable sections of FBC, including but limited to Sections 1504.3.2, 1506.6 and 1507.4.4. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824). FL #: FL 5211.3-R8 Date: 10 / 11 / 2020 Report No.: 20-224-M-S6W-ER Page 4 of 7 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Components/Materials (by Manufacturer): Roof Panel: Product Identification: Material: Thickness: Panel Width: Rib Height: Yield Strength: Corrosion Resistance: M-Seam Steel 26 gauge Minimum 16” (max.) Coverage 1” 40 ksi min. In compliance with FBC Section 1507.4.3: • ASTM A792 coated, or • ASTM A653 G90 galvanized steel Fastener: Type: Size: Penetration Through: Corrosion Resistance: Standard: Pancake-Head Wood Screw #10 (× length to meet min. penetration through deck) 3/16” min. through wood deck Per FBC Section 1506.6 and 1507.4.4 Per ANSI/ASME B18.6.4 Components/Materials (by Others): Underlayment: Material and application shall be in compliance with FBC Section 1507.1.1 and in accordance with applicable code sections and manufacturer’s recommendations. Insulation (Optional): Type: Thickness: Properties: Density: Or Compressive Strength: Rigid Insulation Board 3” (max.) 2.25 pcf (lbs/ft3) min. 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16”. FL #: FL 5211.3-R8 Date: 10 / 11 / 2020 Report No.: 20-224-M-S6W-ER Page 5 of 7 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Installation: Installation Method: (Refer to drawings on Pages 6-7 of this report.)  Fastener spacing: Refer to Table “A” Below (along the length of the panel)  Rib Interlock: Snap Lock (Panel ribs shall be fully engaged to form an integral interlock.)  Minimum fastener penetration thru bottom of support, 3/16”.  For panel construction at the end of panels, refer to manufacturer’s instructions and any site specific design. TABLE “A” ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: - 84.25 PSF - 91.75 PSF Deck Thickness: 15/32” or 19/32” 15/32” or 19/32” Fastener Spacing: 8” 4” * Allowable design pressure for allowable stress design (ASD) with a margin of safety of 2 to 1. Install the “M-Seam” roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 7th Edition (2020). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL580-94 & UL 1897-98 Uplift Test By Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527) Report #: 0232-0508-05, Report Date: 6/29/05, Specimens #1-3 2. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) Millennium Metals Licensee # 423 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) FL #: FL 5211.3-R8 Date: 10 / 11 / 2020 Report No.: 20-224-M-S6W-ER Page 6 of 7 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Installation Method Millennium Metals “M-Seam” Roof Panel Attached to Wood Deck Profile Drawings 16" Coverage 1" 3/4" Optional Striations Typical Panel Profile View (Not To Scale) 16" o.c. Integral Snap Lock #10 Pancake-Head Screw 3/16" min. penetration thru deck Typical Assembly Profile View (Not To Scale) FL #: FL 5211.3-R8 Date: 10 / 11 / 2020 Report No.: 20-224-M-S6W-ER Page 7 of 7 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Installation Method Millennium Metals “M-Seam” Roof Panel Attached to Wood Deck 8" o.c Typical Fastener:#10 Pancake-Head Screw Support:- 15/32" or 19/32" CDX Plywood Deck, or- Wood plank "M-Seam" Roof Panel Insulation:(Optional) 3" max or 25 psi min. Typical Assembly Profile View (Not To Scale) TABLE “A” ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: - 84.25 PSF - 91.75 PSF Deck Thickness: 15/32” or 19/32” 15/32” or 19/32” Fastener Spacing: 8” 4” * Allowable design pressure for allowable stress design (ASD) with a margin of safety of 2 to 1.