Loading...
1205 Hibiscus St ROW21-0071 JEA PoleOWNER:ADDRESS:CITY:STATE:ZIP: HUTCHCRAFT WILL J 1205 HIBISCUS ST ATLANTIC BEACH FL 32233-2609 COMPANY:ADDRESS:CITY:STATE:ZIP: JEA 21 WEST CHURCH ST JACKSONVILLE FL 32202 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171058 0100 ATLANTIC BEACH SEC H JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1205 HIBISCUS ST RIGHT OF WAY SINGLE OR TWO FAMILY RIGHT OF WAY NEW JEA POLE $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed, call 247-5878. 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 12/30/2021 PERMIT NUMBER ROW21-0071 ISSUED: 12/30/2021 EXPIRES: 3/30/2022 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: 3 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list. Approved list can be obtained at the Building Department at City Hall. Roll off container cannot be placed on City right-of-way. 4 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 5 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 2 of 2Issued Date: 12/30/2021 PERMIT NUMBER ROW21-0071 ISSUED: 12/30/2021 EXPIRES: 3/30/2022 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ROW21-0071 CUE Reports Estimate Number: 50613 1205 HIBISCUS ST./ SET 35/4W Estimate Type: SR Contract: 069-19-SPE OH FY22 Estimate Version:By: SIMPRB MWO#/Task: 30770830 Required Date: Oracle Project #: 8006654 Estimated On: 12/09/2021 _________________________________________________________________________________________ Cost Estimate Materials JEA Contractor 1. New Material Cost (w/ sales tax)$341.35 $341.35 2. Transformer Cost (w/ sales tax)$0.00 $0.00 3. Returned Material Salvage Value $0.00 $0.00 Labor 4. Crew Time $275.15 $1,755.51 5. Extraordinary Costs $0.00 $0.00 JEA Overhead 6. Fringe Benefits (45.01% of lines 4 & 7)$158.46 $125.76 7. Engineering Costs (Variable % of line 4)$76.90 $279.40 8. Project Equipment Costs (40% of total equipment costs)$164.74 $0.00 9. Material Handling (7.18% of lines 1 & 2)$24.51 $24.51 10. Inspection (6.84% of line 4)$0.00 $120.08 11. Total Cost of Project $1,041.10 $2,646.61 12. Work Order Estimate (Line 11 minus line 8, 9, & 10)$851.86 $2,622.10 13. Billable Equipment Depreciation (60% of total equipment costs)$247.11 $0.00 14. Billing Estimate (Including Transformer Cost) (Lines 11 + 13 + (64.66% of 4 & 7))$1,515.85 $2,827.27 15. Billing Estimate (W/O Transformer Cost) (Lines 11 + 13 + (64.66% of 4 & 7) - Line 2)$1,515.85 $2,827.27 _________________________________________________________________________________________ Time Estimate Crew Hours Total Manhours 1.74 6.95 ----------------------------------------------------------------------------------------------------------------------------------- ROW21-0071 CUE Reports Estimate Number: 50613 1205 HIBISCUS ST./ SET 35/4W Estimate Type: SR Contract: 069-19-SPE OH FY22 Estimate Version: By: SIMPRB MWO#/Task: 30770830 Required Date: Oracle Project #: 8006654 Estimated On: 12/09/2021 _________________________________________________________________________________________ CU Detail StationStation:01 1215 HIBISCUS ST. SET 35/4W AND OH Build Transfer Remain in Place Remove C.2/0P 75 G3W*2 1 P.35/4W 1 S4*2/0 1 StationStation:2 1266 HIBISCUS ST. MAKE UP SEC. Build Transfer Remain in Place Remove RUBUP 2 S20ES*4/0-2/0 1 S4*2/0 1 RUBDOWN 2 _____________________________________________________________________________________________________________________________ CUE Reports Estimate Number: 50613 1205 HIBISCUS ST./ SET 35/4W Estimate Type: SR Contract: 069-19-SPE OH FY22 Estimate Version: By: SIMPRB MWO#/Task: 30770830 Required Date: Oracle Project #: 8006654 Estimated On: 12/09/2021 _________________________________________________________________________________________ Conductor, Conduit and Pipe Detail Quantities From Station To Station CU Build Transfer Remain Remove 01 2 C.2/0P 75 0 0 0 CUE Reports Estimate Number: 50613 1205 HIBISCUS ST./ SET 35/4W Estimate Type: SR Contract: 069-19-SPE OH FY22 Estimate Version: By: SIMPRB MWO#/Task: 30770830 Required Date: Oracle Project #: 8006654 Estimated On: 12/09/2021 _________________________________________________________________________________________ Material Summary Item Quantity Item Number Item Description 75 CAIOS002 CABLE, 2/0 (PAP), OVERHEAD SERVICE DROP, 600 VOLT MULTIPLEX CABLE "MESA VERDE" PRE-ASSEMBLED PARALLEL SOUTHWIRE 61- 28-96-1, 1500 FOOT REELS 1 CLAGR001 CLAMP, GROUND ROD, 5/8" - 4SOL "HAMMERLOCK" 1 CLASR002 CLAMP, STRAIN RELIEF WEDGE, ALUMINUM, 1/0 TRI - 4/0 PAP 2 CLASS004 CLAMP, STRAIGHT STRAIN, ALUMINUM, 5000#, 4-3/0 ALUM 2 CNNCP002 CONNECTOR, #2, 6-2 MAIN, 2-1/0 TAP, ALUMINUM COMPRESSION, PARALLEL TAP, 3 CNNCP006 CONNECTOR, #6, 1/0-2/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP, ALUMINUM, 1 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL, VISE GRIP PARALLEL, BRONZE 3 COBCO028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON PLASTIC REEL, 4" X 11.5" W/ 2" HOLE 70 COBCW014 CONDUCTOR, #4, TYPE 40 DSA, COPPERWELD & COPPERWELD- COPPER .204" DIAMETER 1480# BREAKING STRENGTH ( 50# COIL - 427' ) 2 COVIC002 COVER, "D" DIE, INSULATING, 2-1/2" 1 GUAGW001 GUARD, GROUND WIRE, 1/2" X 1/2" X 96", GRAY PLASTIC 2 INSSU002 INSULATOR, SUSPENSION, 4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 1 POLWO003 POLE, WOOD, 35' CLASS 4 (T/L = 44), WEIGHT=1,026 LBS 1 RODGR003 ROD, GROUND, THREADLESS, 5/8" X 8', SHIP ON OPEN FLATBED ONLY! 1 TAGHO007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR "SLIDE IN" CHARACTERS)). 19.5" HIGH X 2" WIDE WITH 3-1/8" NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) CUE Reports Estimate Number: 50613 1205 HIBISCUS ST./ SET 35/4W Estimate Type: SR Contract: 069-19-SPE OH FY22 Estimate Version: By: SIMPRB MWO#/Task: 30770830 Required Date: Oracle Project #: 8006654 Estimated On: 12/09/2021 _________________________________________________________________________________________ CU Summary BUILD CU Name Quantity Description C.2/0P 75 2/0 AAC PAP W/ 2/0 AAAC NEUTRAL G3W*2 1 WOOD POLE - NON-EQUIPMENT GROUND P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBUP 2 LINE RUBBER INSTALLATION, PER SECT. S20ES*4/0-2/0 1 SECONDARY CONNECTION AT POLE S4*2/0 2 SECONDARY DEADEND REMOVE CU Name Quantity Description RUBDOWN 2 LINE RUBBER REMOVAL, PER SECT. CUE Reports Estimate Number: 50613 1205 HIBISCUS ST./ SET 35/4W Estimate Type: SR Contract: 069-19-SPE OH FY22 Estimate Version: By: SIMPRB MWO#/Task: 30770830 Required Date: Oracle Project #: 8006654 Estimated On: 12/09/2021 _________________________________________________________________________________________ CU's with Zero for Contractor CU Name Workfunction Quantity RUBDOWN REMOVE 2 ã U Ø Ø D D D D D D 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 #* #* #* #* #* #* #* #* ® ® ® ® ® T $T $ T $ T $ T " ¯ ¯ ¯ 8 2/ 0 P 1/ 0 T 1/ 0 T 1/ 0 T 4T 1/ 0 T 1 /0 T 4T 2/ 0 P 1/ 0 T 1 /0 T 1/ 0 T 1/ 0 T T 2/0P 2 /0P 1/0T 1 /0 T 1 /0 T T 1/ 0 T 2/0P 1151 1275 1189 25C 25C 50C 1266 1201 50C 132155 ST O C K S S T 14TH ST W HI B I S C U S S T __________________ ORACLE PROJECT #:50613 ________________________ PERMIT N.O.:30770830 __________________ MAXIMO WO #:8006654 _______________ DATE REL CONST:12/13/21 ____________________________________________________SUB-STA:NEPTUNE BEACH __________ CIR. N.O.:561 ____________________________________________________ENGINEER:ROBERT SIMPSON _______________ CELL N.O.:N/A __________ PHONE N.O.:665-7793____________________________________________________ CUSTOMER/ LOCATION:1205 HIBISCUS ST../ 35/4W INSTALL 561 __________________ SVC CENTER:SSSC __________ TREE TRIMMING REQ'D:NO __________________ZIP CODE:N/A ENGINEERING DESIGN / STA 1 STA 2 STA 1, P# 1215 HIBISTCUS ST./ SET 35/4W, RUN NEW 2/0P TO STA 2. STA 2, P# 1266 HIBISTCUS ST. ***** SERVICE UPGRADE ***** ROW21-0071