Loading...
44 Dewees Ave ACRS21-0329 HVAC revisionJob #: Performed for: Slater Residence 44 Dewes Ave Atlantic Beach, FL Exclusively for the use of: Environmental Air Cond iti onin g Scale: 1 : 82 Page 1 Right-Suite® Universal 2019 19.0.17 RSU17457 2021-Dec-15 22:13:48 ...dence, 44 Dewes Ave, Atl Bch.rup N 1st Floor Entry Guest Bed 1 Guest Bath 1 Guest Bed 2 Bed 3 Den Hall 1 Guest Bath 2 64 cfm 136 cfm 100 cfm 77 cfm 6 " 5 " 6 " 196 cfm 4 " 800 cfm 12 " 12 " 12 " 6 " 10 " 8 " 115 cfm7 " 8 " 116 cfm 6 " Job #: Performed for: Slater Residence 44 Dewes Ave Atlantic Beach, FL Exclusively for the use of: Environmental Air Cond iti onin g Scale: 1 : 82 Page 2 Right-Suite® Universal 2019 19.0.17 RSU17457 2021-Dec-15 22:13:48 ...dence, 44 Dewes Ave, Atl Bch.rup N 2nd Floor Dining Room Living Room Owner Bath Powder Kitchen Pantry Owner Closet Master Bed W IC Hallway 21 cfm 501 cfm 9 cfm 81 cfm 54 cfm 4 " 4 " 5 " 4 " 14 " 132 cfm 7 " 501 cfm 14 " 12 " 132 cfm 7 " 164 cfm 10 " 6 " 122 cfm 6 " 122 cfm 6 " 17 " 85 cfm 6 " 85 cfm 6 " Bold/italic values have been manually overridden 2021-Dec-15 22:13:45 Right-Suite® Universal 2019 19.0.17 RSU17457 Page 1 ...AC, Slater Residence, 44 Dewes Ave, Atl Bch.rup Calc = MJ8 Front Door faces: N Job:Duct System Summary Date: 1st Floor By: Exclusively for the use of:, Environmental Air Conditioning Project Information Slater ResidenceFor: 44 Dewes Ave, Atlantic Beach, FL CoolingHeating External static pressure in H2O0.20in H2O0.20 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.20in H2O0.20 Supply / return available pressure 0.100 / 0.100 in H2O in H2O0.100 / 0.100 Lowest friction rate in/100ft0.099in/100ft0.099 Actual air flow cfm800cfm800 Total effective length (TEL)ft203 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st3180.023.0ShMt0x06.00.0991361364804cBed 3 st1140.030.0ShMt0x07.00.1181151153930hDen st2180.018.0ShMt0x04.00.1011941966686hEntry st3140.012.0ShMt0x06.00.13264622239cGuest Bath 1 st2150.021.0ShMt0x05.00.11775772637hGuest Bath 2 st2140.012.0ShMt0x06.00.132100983536cGuest Bed 1 st1105.014.0ShMt0x06.00.1681161154074cGuest Bed 2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 230 231 0.118 662 8.0 0x0 ShtMetl st2 Peak AVF 371 369 0.101 681 10.0 0x0 ShtMetl st3 Peak AVF 198 200 0.099 573 8.0 0x0 ShtMetl Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb4 0x 8000 800 0 0 0 0 x0 0 ShMt Bold/italic values have been manually overridden 2021-Dec-15 22:13:45 Right-Suite® Universal 2019 19.0.17 RSU17457 Page 2 ...AC, Slater Residence, 44 Dewes Ave, Atl Bch.rup Calc = MJ8 Front Door faces: N Job:Duct System Summary Date: 2nd Floor By: Exclusively for the use of:, Environmental Air Conditioning Project Information Slater ResidenceFor: 44 Dewes Ave, Atlantic Beach, FL CoolingHeating External static pressure in H2O0.20in H2O0.20 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.20in H2O0.20 Supply / return available pressure 0.122 / 0.078 in H2O in H2O0.122 / 0.078 Lowest friction rate in/100ft0.062in/100ft0.062 Actual air flow cfm1000cfm1000 Total effective length (TEL)ft325 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st4175.015.0ShMt0x06.00.06484852341hDining Room st4175.024.0ShMt0x06.00.06284852341hDining Room-A st4165.013.0ShMt0x06.00.0691641634872cKitchen st4140.014.0ShMt0x06.00.0801221223381hLiving Room st4140.023.0ShMt0x06.00.0751221223381hLiving Room-A st5140.023.0ShMt0x07.00.0751311323660hMaster Bed st5105.032.0ShMt0x07.00.0891311323660hMaster Bed-A st4160.015.0ShMt0x05.00.07081802413cOwner Bath st5150.08.0ShMt0x04.00.0782118613cOwner Closet st4150.09.0ShMt0x04.00.07798261cPowder st5160.018.0ShMt0x04.00.06952541492hWIC Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st4 Peak AVF 664 666 0.062 623 14.0 0x0 ShtMetl st5 Peak AVF 336 334 0.069 617 10.0 0x0 ShtMetl Bold/italic values have been manually overridden 2021-Dec-15 22:13:45 Right-Suite® Universal 2019 19.0.17 RSU17457 Page 3 ...AC, Slater Residence, 44 Dewes Ave, Atl Bch.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb7 0x 5010 499 126.0 0.062 637 12.0 x0 0 ShMt rt1 rb5 0x 4990 501 116.0 0.067 468 14.0 x0 0 ShMt rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 1000 1000 0.062 634 17.0 0x0 ShtMetl