338 6th St ROOF20-0028 Metal RoofOWNER:ADDRESS:CITY:STATE:ZIP:
FORD DONALD COLIN 338 6TH ST ATLANTIC BEACH FL 32233-5348
COMPANY:ADDRESS:CITY:STATE:ZIP:
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169863 0000 ATLANTIC BEACH
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
338 6TH ST ROOF NON SHINGLE repair roof with metal roof $2350.00
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $65.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $32.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $101.50
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 1Issued Date: 1/5/2022
PERMIT NUMBER
ROOF20-0028
ISSUED: 1/5/2022
EXPIRES: 7/4/2022
ROOF NON SHINGLE PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
DESCRIPTION ACCOUNT QTY PAID
PermitTRAK $101.50
ROOF20-0028 Address: 338 6TH ST APN: 169863 0000 $101.50
BUILDING $65.00
BUILDING PERMIT 455-0000-322-1000 0 $65.00
BUILDING PLAN REVIEW $32.50
BUILDING PLAN CHECK 455-0000-322-1001 0 $32.50
STATE SURCHARGES $4.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL FEES PAID BY RECEIPT: R18416 $101.50
Printed: Wednesday, January 5, 2022 9:15 AM
Date Paid: Wednesday, January 05, 2022
Paid By: FORD DONALD COLIN
Pay Method: CREDIT CARD 570522232
1 of 1
Cashier: CG
Cash Register Receipt
City of Atlantic Beach
Receipt Number
R18416
FL 9555.1-R4
C2172-1
8.20.2017
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Support Description: Nom. 1" x 4" (min) lumber (Southern Yellow Pine Untreated)
(Must be designed by others)
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 70.25 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) (3 or more spans)
Panel Attachment: #9-15 or #10-14 x 1-1/2" long wood screws with washer
At panel ends @ 12" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with ASTM E1592-01 ‘Test
Method for Structural Performance of Sheet Metal Roof and Siding
Systems by Uniform Static Air Pressure Difference’ and FM 4470
Section 5.5 ‘Resistance to Foot Traffic’.
Test Equivalency: The test procedure in ASTM E1592-01 comply with test procedure
prescribed in ASTM E1592-05(2012).
The test procedure in FM 4470 (1992) comply with test procedure
prescribed in FM 4470 (2012).
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer. This product is not approved for use in the High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
approved roofing materials directory for fire ratings of this product.
FL 9555.1-R4
C2172-1
8.20.2017
Page 3 of 3
Supporting Documents: ASTM E1592 Test Report
Farabaugh Engineering and Testing Inc
Project No. T246-06, Revised Reporting Date 11/7/06
FM 4470 Test Report
ENCON Technology Inc
C1583-3, Reporting Date 7/24/08