Loading...
338 6th St ROOF20-0028 Metal RoofOWNER:ADDRESS:CITY:STATE:ZIP: FORD DONALD COLIN 338 6TH ST ATLANTIC BEACH FL 32233-5348 COMPANY:ADDRESS:CITY:STATE:ZIP: TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169863 0000 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 338 6TH ST ROOF NON SHINGLE repair roof with metal roof $2350.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $65.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $32.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $101.50 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 1Issued Date: 1/5/2022 PERMIT NUMBER ROOF20-0028 ISSUED: 1/5/2022 EXPIRES: 7/4/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $101.50 ROOF20-0028 Address: 338 6TH ST APN: 169863 0000 $101.50 BUILDING $65.00 BUILDING PERMIT 455-0000-322-1000 0 $65.00 BUILDING PLAN REVIEW $32.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $32.50 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R18416 $101.50 Printed: Wednesday, January 5, 2022 9:15 AM Date Paid: Wednesday, January 05, 2022 Paid By: FORD DONALD COLIN Pay Method: CREDIT CARD 570522232 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R18416 FL 9555.1-R4 C2172-1 8.20.2017 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: 5V Panel Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Support Description: Nom. 1" x 4" (min) lumber (Southern Yellow Pine Untreated) (Must be designed by others) Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2 Design Uplift Pressure: 70.25 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) (3 or more spans) Panel Attachment: #9-15 or #10-14 x 1-1/2" long wood screws with washer At panel ends @ 12" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with ASTM E1592-01 ‘Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference’ and FM 4470 Section 5.5 ‘Resistance to Foot Traffic’. Test Equivalency: The test procedure in ASTM E1592-01 comply with test procedure prescribed in ASTM E1592-05(2012). The test procedure in FM 4470 (1992) comply with test procedure prescribed in FM 4470 (2012). Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. The design uplift pressure for reduced support spacing may be computed using rational analysis prepared by a Florida Professional Engineer. This product is not approved for use in the High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory for fire ratings of this product. FL 9555.1-R4 C2172-1 8.20.2017 Page 3 of 3 Supporting Documents: ASTM E1592 Test Report Farabaugh Engineering and Testing Inc Project No. T246-06, Revised Reporting Date 11/7/06 FM 4470 Test Report ENCON Technology Inc C1583-3, Reporting Date 7/24/08