Loading...
338 6th St ROOF21-0101 Garage Metal Roof and FramingOWNER:ADDRESS:CITY:STATE:ZIP: FORD DONALD COLIN 338 6TH ST ATLANTIC BEACH FL 32233-5348 COMPANY:ADDRESS:CITY:STATE:ZIP: TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169863 0000 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 338 6TH ST ROOF NON SHINGLE GARAGE METAL ROOF AND FRAMING $2200.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $65.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $32.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $101.50 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 1Issued Date: 1/5/2022 PERMIT NUMBER ROOF21-0101 ISSUED: 1/5/2022 EXPIRES: 7/4/2022 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QTY PAID PermitTRAK $101.50 ROOF21-0101 Address: 338 6TH ST APN: 169863 0000 $101.50 BUILDING $65.00 BUILDING PERMIT 455-0000-322-1000 0 $65.00 BUILDING PLAN REVIEW $32.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $32.50 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL FEES PAID BY RECEIPT: R18415 $101.50 Printed: Wednesday, January 5, 2022 9:12 AM Date Paid: Wednesday, January 05, 2022 Paid By: FORD DONALD COLIN Pay Method: CREDIT CARD 570522232 1 of 1 Cashier: CG Cash Register Receipt City of Atlantic Beach Receipt Number R18415 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION ROOF21-0101 ROOF21-0101 FL 9555.5-R5 C2373-5 8.8.2020 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: MasterRib Panel Panel Description: 36" wide coverage with 3/4" high ribs at 9" o.c. Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Corrosion resistant as per FBC 2020 Section 1507.4.3. Support Description: Nom. 2" x 2" (min) SPF, SYP or DF lumber. (Must be designed by others) Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2 Design Pressure: +27.1 and -36.2 psf at support spacing of 48" o.c. (Based on testing) (at 3 span condition with FS = 2.0) Panel Attachment: #9-15 or #10-14 x 1.5" long wood screws with washers. Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4. At panel ends at 3.5"-5.5"-3.5" o.c. across panel width At intermediate at 9" o.c. across panel width Sidelap Attachment: ¼"-14 x 7/8" long SDS with washer at 24" o.c. Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4. Test Standards: Panel assembly tested in accordance with ASTM E1592-01 ‘Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference’ and FM 4470 Section 5.5 ‘Resistance to Foot Traffic’. Test Equivalency: The test procedure in ASTM E1592-01 comply with test procedure prescribed in ASTM E1592-05(2012). The test procedure in FM 4470 (1992) comply with test procedure prescribed in FM 4470 (2016) Section 4.6 ‘Resistance to Foot Traffic’. Code Compliance: The product described herein has demonstrated compliance with FBC 2020 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. The design pressure for reduced support spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Union Corrugating load span table. This product is not approved for use in the High Velocity Hurricane Zone. Fire FL 9555.5-R5 C2373-5 8.8.2020 Page 3 of 3 classification is not within scope of this Evaluation Report. Refer to FBC 2020 Section 1505 and current approved roofing materials directory for fire ratings of this product. Supporting Documents: ASTM E1592 Test Report ENCON Technology Inc. C1514-1 (Test #2 & 3), Reporting Date 9/8/07 FM 4470 Test Report ENCON Technology Inc. C1583-2, Reporting Date 7/24/08