Loading...
1 FLEET LANDING Coleman Bldg Reno COMM21-0042 _STRU permit set_1SHEET PRINTED ON:FILE PATH:DATE: 1414 UNDERWOOD AVE. WAUWATOSA, WI 53213 414.431.3131 TEL 414.431.0531 FAX WWW.AGARCH.COM AG PROJECT NUMBER: SHEET INDEX OWNER DEVELOPMENT CONSULTANT Clark Advisory Services 1015 Atlantic Boulevard Atlantic Beach, FL 32233 904.834.9373 407.235.8053 (C) One Fleet Landing Boulevard Atlantic Beach, FL 32233 Fleet Landing FOOD SERVICE CONSULTANT Scopos Hospitality Group 300 West Chestnut Street, Suite 201 Ephrata, PA 17522 717.733.5810 INTERIOR DESIGN Studio 121 Inc. 2305 Kline Ave Suite 100 Nashville, TN 37211 615.469.4121 615.469.6121 (fax) STRUCTURAL CONSULTANT McVeigh & Mangum Engineering, Inc 9133 RG Skinner Pkwy Jacksonville, FL 62256 904.438.5200 MEP CONSULTANT Professional Engineering Consultants 303 South Topeka Wichita, KS 67202 (316) 206-1456 PERMIT SET 7/29/2021 4:05:24 PMBIM 360://200801-Fleet Coleman Remodel/201162 Coleman Bldg at Fleet Landing_STRU_R20.rvtAtlantic Beach, Florida Coleman Remodel 16 APRIL 2021 200801 STRUCTURAL S000 COVER SHEET S001 DESIGN CRITERIA & GENERAL NOTES S100 FOUNDATION PLAN S101 2ND FLOOR FRAMING PLAN S102 ROOF FRAMING PLAN S201 SPORTS BAR, DUMB WAITER, AND STAIR SECTIONS S301 HOOD, STATUE SUPPORT AND ELEVATOR LOBBY SECTIONS METAL DECK S/S SD STEEL JOIST CALCULATIONS S/S SD STRUCTURAL STEEL CONNECTIONS S/S SD STRUCTURAL STEEL S/S SD CONCRETE MIX DESIGNS S/S SD CONCRETE EMBED LAYOUT S/S SD CONCRETE CONSTRUCTION JOINT LAYOUT S/S SD CONCRETE REINFORCING LAYOUT S/S SD PRE-ENGINEERED METAL STAIRS AND LANDINGS S/S SD MISC STEEL FABRICATIONS S/S SD EXTERIOR CLADDING (CURTAINWALLS)S/S SD STEEL JOIST DRAWINGS S/S SD N GENERAL SYMBOLS PLAN, SECTION OR DETAIL NO SHEET NUMBER KEYED NOTE TO PLAN NORTH ARROW 1 S STRUCTURAL ABBREVIATIONS 1 GA GALV GB GC GT HGT HORIZ HSA HT IF INFO INT JNT JST LB LG LLH LLV LSH LSV MANUF MAT'L MAX MECH MIN MISC NIC NO or No NS NTS OC OD OF O/O OPNG OPP PEMB PERP PL PNL PREFAB PSF PSI PT QTY R or RAD RD REF REINF REQ REQ'D RET REV GAGE GALVANIZED GRADE BEAM GENERAL CONTRACTOR GIRDER TRUSS HEIGHT HORIZONTAL HEADED STUD ANCHOR HIP TRUSS INSIDE FACE INFORMATION INTERIOR JOINT JOIST POUND LONG LONG LEG HORIZONTAL LONG LEG VERTICAL LONG SIDE HORIZONTAL LONG SIDE VERTICAL MANUFACTURER MATERIAL MAXIMUM MECHANICAL MINIMUM MISCELLANEOUS NOT IN CONTRACT NUMBER NEAR SIDE NOT TO SCALE ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OUT TO OUT OPENING OPPOSITE PRE-ENGINEERED METAL BUILDING PERPENDICULAR PLATE PANEL PREFABRICATED POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POST TENSIONED QUANTITY RADIUS ROUND REFERENCE REINFORCE(MENT) REQUIRE REQUIRED RETAINING REVISION # Ø □ & @ ALUM AR ARCH ASSY B/ BETWN BLDG BM BOT BPL BRG C TO C CANT CFS CJ CL CLR CMU COL CONC CONN CONST CONT CONTR CTR CTRD DBA DEFL DET DIA DIAG DIFF DIM DO DWG EA EF EJ EL ELEC ELEV ENGR EOD EOR EOS EQ EQUIP EXIST EXP EXT EW FB FD FDN FF FLR FS FTG NUMBER OR POUND ROUND OR DIAMETER SQUARE AND AT ALUMINUM ANCHOR ROD ARCHITECTURE ASSEMBLY BOTTOM OF BETWEEN BUILDING BEAM BOTTOM BASE PLATE BEARING CENTER TO CENTER CANTILEVER COLD FORMED STEEL CONSTRUCTION JOINT CENTER LINE CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONTRACTION CENTER CENTERED DEFORMED BAR ANCHOR DEFLECTION DETAIL DIAMETER DIAGONAL DIFFERENT DIMENSION DITTO DRAWING EACH EACH FACE EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR ENGINEER EDGE OF DECK ENGINEER OF RECORD EDGE OF SLAB EQUAL EQUIPMENT EXISTING EXPANSION EXTERIOR EACH WAY FLAT BAR FLOOR DRAIN FOUNDATION FINISH FLOOR FLOOR FAR SIDE FOOTING SECT SCHED SIM SOG SP SPA SPEC SQ STD STIFF STL STR STRUCT SYM SYP T&B T/ T/U PANEL TE THK THRD TRANSV TS TYP UON VER VERT WA w/ or W/ w/o WP WS WWF SECTION SCHEDULE SIMILAR SLAB ON GRADE SPRUCE PINE SPACE SPECIFICATION SQUARE STANDARD STIFFENER STEEL STRAIGHT STRUCTURAL SYMMETRICAL SOUTHERN YELLOW PINE TOP & BOTTOM TOP OF TILT-UP PANEL THICKENED EDGE THICK THREADED TRANSVERSE THICKENED SLAB TYPICAL UNLESS OTHERWISE NOTED VERIFY VERTICAL WHERE APPLICABLE WITH WITHOUT WORK POINT WATERSTOP WELDED WIRE FABRIC FOUNDATION TYPE REVISION NUMBER FOOTING STEP 1 GENERAL NOTES STEEL ALL BOLTS SHALL BE SNUG TIGHT (AS DEFINED BY AISC) UON. UNLESS OTHERWISE NOTED, BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE AS SHOWN IN DETAIL 1/S301. BEAM REACTIONS AND CONNECTIONS THAT FALL OUTSIDE OF THE LIMITS OF THE DETAILS NOTED ABOVE SHALL BE DESIGNED BY THE SPECIALTY ENGINEER LICENSED IN THE STATE OF THE PROJECT AND SHALL BE SUBMITTED AS SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL. MINIMUM SIZE OF ALL FILLET WELDS SHALL CONFORM TO SECTION J2 AISC SPECIFICATIONS EVEN THOUGH SHOWN OTHERWISE ON ARCHITECTURAL, MECHANICAL, OR STRUCTURAL DRAWINGS. ALL WELDS ALONG THE LENGTH OF MEMBERS INDICATED ON ARCHITECTURAL OR STRUCTURAL DRAWINGS, BUT NOT SIZED, SHALL BE A MINIMUM OF: PROVIDE ANGLE SUPPORT (USE L2-1/2x2-1/2x1/4) ALONG FACE OF STEEL COLUMNS WHERE METAL DECK OR GRATING SPANS INTO IT. NON-COMPOSITE STEEL FLOOR DECK SHALL BE ATTACHED WITH 5/8" DIA PUDDLE WELDS (USE WELD WASHERS WHEN DECK IS LESS THAN 22 GA). WELD SIDELAPS EA SIDE @ EA BEAM OR JOIST. PROVIDE WELDS AT 18" AT END LAPS. PROVIDE PERIMETER WELDS AT 18" MAX. 3/16 2-12 3/16 2-12 DESIGN CRITERIA OPEN WEB STEEL JOIST (DESIGN PER CURRENT EDITION SJI WITH AN ALLOWABLE TENSILE STRESS OF 30,000 PSI) STRUCTURAL STEEL (DESIGN PER CURRENT EDITION AISC), UNLESS OTHERWISE NOTED (UON) MATERIALS SHALL BE AS FOLLOWS: DESIGN PER 2020 FLORIDA BUILDING CODE, UNLESS OTHERWISE NOTED. ALL REINFORCING STEEL ASTM A615 GRADE 60. REINFORCING STEEL SHOWN ON THESE DRAWINGS TO BE WELDED SHALL BE ASTM A706 AND WELDING SHALL BE IN ACCORDANCE WITH AWS D1.4. 130 MPH 101 MPH 40 FT II C ENCLOSED ± 0.18 0.85 PER CODE FASTENERS EXPANSION BOLTS SHALL BE HILTI KWIK BOLT 3, SIMPSON STRONG-TIE STRONG-BOLT2, DEWALT POWER-STUD+ SD1 OR APPROVED EQUAL, UON. EMBEDMENT DEPTH INTO CONCRETE OR SOLID GROUTED MASONRY SHALL BE AT LEAST 7 TIMES THE BOLT DIAMETER, UON. CLEAN HOLE AND INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS. SCREW ANCHORS SHALL BE HILTI KWIK HUS-EZ, SIMPSON STRONG-TIE TITEN HD, DEWALT SCREW-BOLT+ OR APPROVED EQUAL, UON. EMBEDMENT IN CONCRETE OR SOLID GROUTED MASONRY SHALL BE AT LEAST 9 TIMES THE BOLT DIAMETER, UON. CLEAN HOLE AND INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS. POWER ACTUATED FASTENERS (PAF) SHALL BE 0.157" DIAMETER HILTI X-U, SIMPSON STRONG- TIE PDPA, DEWALT CSI PIN OR EQUAL, UON. EMBED MIN 1-1/4" INTO CONCRETE AND CMU, UON. DO NOT PLACE WITHIN 1" OF CMU MORTAR JOINT. PAF SHALL COMPLETELY PENETRATE STRUCTURAL STEEL. ADHESIVE ANCHORING (EPOXY): • ADHESIVE ANCHORING FOR CONCRETE SHALL BE HILTI RE-500 V3 CARTRIDGE SYSTEM, SIMPSON STRONG-TIE SET-3G, DEWALT PURE 110+ (OR EQUIVLANT ACRYLIC AC200+, HY 200, OR ATXP) OR APPROVED EQUAL, UON. EMBEDMENT DEPTH SHALL BE AT LEAST 12 TIMES THE INSERT DIAMETER, UON. HOLE DIAMETER SHALL BE NO GREATER THAN RECOMMENDED BY MANUFACTURER. THE HOLE SHALL BE CLEANED PER MANUFACTURER'S RECOMMENDATIONS BY BRUSHING OUT WITH WIRE BOTTLE BRUSH AND BLOWN OUT WITH AIR USING A COMPRESSOR WITH A FUNCTIONAL OIL TRAP (EXCEPT WHERE PERMITTED WHEN USING A DUST EXTRACTION SYSTEM IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS). • ADHESIVE ANCHORING FOR MASONRY SHALL BE HILTI HIT-HY 70 OR HY 270 CARTRIDGE SYSTEM, SIMPSON STRONG-TIE SET-XP, DEWALT AC100+ OR APPROVED EQUAL, UON. EMBEDMENT DEPTH INTO SOLID GROUTED MASONRY SHALL BE AT LEAST 9 TIMES THE INSERT DIAMETER, UON. HOLE DIAMETER SHALL BE NO GREATER THAN RECOMMENDED BY MANUFACTURER. HOLES SHALL NOT BE PLACED WITHIN 1" OF A VERTICAL MORTAR JOINT. CLEAN HOLE IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS. • GENERAL - ANCHORS SHALL MEET THE REQUIREMENTS OF ACI 355.4. INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND PERFORMED BY AN INSTALLER TRAINED BY THE MANUFACTURER. INSTALLATION OF ADHESIVE ANCHORS HORIZONTALLY OR UPWARDLY, WHICH SUPPORT SUSTAINED TENSION LOADS SHALL BE PERFORMED BY A CERTIFIED ADHESIVE ANCHOR INSTALLER IN ACCORDANCE WITH ACI318 AND CONTINUOUSLY INSPECTED PER ACI318. PROOF OF CURRENT CERTIFICATION SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL. • CAPACITIES - UON, DESIGN BOND STRENGTH OF ANCHORS HAVE BEEN BASED ON CRACKED CONCRETE, ACI 355.4 TEMPERATURE CATEGORY B, AND INSTALLATIONS INTO DRY HOLES DRILLED WITH A ROTARY IMPACT DRILL OR ROCK DRILL INTO CONCRETE THAT HAS CURED AT LEAST 21 DAYS AND HAS A CONCRETE TEMPERATURE OF AT LEAST 50 DEGREES F AT TIME OF ANCHOR INSTALLATION. SPECIFICATIONS CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 301. "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" (LATEST EDITION). EXCEPT AS MODIFIED BY THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL EMPLOY AND PAY AN INDEPENDENT TESTING LABORATORY TO PERFORM CONCRETE TESTING. ALL STRUCTURAL STEEL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF AISC "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS", AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES", AND AWS D1.1" "STRUCTURAL WELDING CODE", EXCEPT AS MODIFIED BY THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. PROOF OF WELDER CERTIFICATION SHALL BE AVAILABLE AT THE JOB SITE DURING TIMES OF INSPECTION. BOLTED CONNECTIONS SHALL BE ASSEMBLED AND INSPECTED IN ACCORDANCE WITH RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS". STEEL JOIST AND JOIST GIRDERS WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITIONS OF THE STEEL JOIST INSTITUTE (SJI) "STANDARD SPECIFICATIONS FOR OPEN WEB STEEL JOISTS, K-SERIES" AND "STANDARD SPECIFICATIONS FOR JOIST GIRDERS". BOLTED AND WELDED CONNECTIONS: THE CONTRACTOR SHALL EMPLOY AND PAY AN INDEPENDENT TESTING LABORATORY TO INSURE THAT ALL FASTENERS AND WELDS ARE INSTALLED IN ACCORDANCE WITH THE SPECIFICATIONS. A VISUAL INSPECTION SHALL BE MADE OF ALL WELDED AND BOLTED CONNECTIONS. IN ADDITION, A MINIMUM OF 10% OF ALL HIGH STRENGTH BOLTS SHALL BE CHECKED FOR PROPER TENSION AND A MINIMUM OF 10% OF ALL FULL PENETRATION WELDS SHALL BE CHECKED BY ULTRASONIC TESTING. ADDITIONAL BOLTS AND WELDS MAY BE TESTED AT THE OPTION OF THE TESTING LAB REPRESENTATIVE. DEFECTIVE BOLTS OR WELDS SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL COST TO THE OWNER. GALVANIZING: CONFORM TO ASTM STANDARDS A 123, A 386, AND A 153 AS APPLICABLE WHEREVER SURFACES ARE INDICATED OR SPECIFIED TO BE GALVANIZED. GALVANIZE AFTER FABRICATION UNLESS OTHERWISE INDICATED OR SPECIFIED. REPAIR ALL GALVANIZED COATINGS THAT BECOME DAMAGED IN HANDLING, TRANSPORTING, WELDING, OR BOLTING. MAKE THE REPAIRS BY APPLICATION OF A GALVANIZING REPAIR PAINT CONFORMING TO ASTM A 780. CLEAN ALL AREAS THAT ARE TO BE REPAIRED; REMOVE SLAG FROM WELDS. APPLY REPAIR PAINT TO COLD SURFACES. METAL DECK WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITION OF THE STEEL DECK INSTITUTE (SDI) SPECIFICATIONS AND COMMENTARY FOR STEEL ROOF DECK", "SDI SPECIFICATIONS AND COMMENTARY FOR COMPOSITE STEEL FLOOR DECK", "SDI SPECIFICATIONS AND COMMENTARY FOR NON-COMPOSITE FLOOR DECK", AND "SDI CODE OF RECOMMENDED STANDARD PRACTICE FOR COMPOSITE DECK, FORM DECK AND ROOF DECK CONSTRUCTION". A GEOTECHNICAL ENGINEER SHALL BE EMPLOYED TO CONFIRM BEARING PRESSURE STATED PRIOR TO CONSTRUCTION. THE ENGINEER SHALL DEVELOP & ENSURE IMPLEMENTATION OF A SITE PREPARATION PROGRAM AS HE DEEMS NECESSARY TO ACHIEVE THE STATED BEARING PRESSURE. FOOTING AND SLAB SUBGRADE PREPARATION SHALL BE IN COMPLIANCE WITH APPLICABLE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. ASTM A1064 SUPPLEMENTARY NOTES PROVIDE ALL TEMPORARY BRACING, SHORING, GUYING OR OTHER MEANS TO AVOID EXCESSIVE STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. THE STRUCTURE SHOULD NOT BE CONSIDERED STABLE UNTIL ALL STRUCTURAL ELEMENTS HAVE BEEN CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. MCVEIGH & MANGUM ENGINEERING, INC OR ANY OF ITS EMPLOYEES SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES OR SEQUENCES FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING THE WORK, OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. VISUAL OBSERVATIONS OF THE STRUCTURAL SYSTEM BY MCVEIGH & MANGUM ENGINEERING FOR GENERAL CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR THE INSPECTIONS REQUIRED BY THE INTERNATIONAL BUILDING CODE. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR EMBEDS, OPENINGS, SLEEVES, ETC. NOT SHOWN ON THE STRUCTURAL DRAWINGS. ALL STRUCTURAL OPENINGS AROUND OR AFFECTED BY MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT SHALL BE VERIFIED WITH EQUIPMENT PURCHASED BEFORE PROCEEDING WITH STRUCTURAL WORK AFFECTED. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS OF EXISTING STRUCTURE AND SITES THAT ARE AFFECTED BY NEW WORK BEFORE PROCEEDING WITH FABRICATION AND CONSTRUCTION. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF THE PROJECT. SHOP DRAWINGS AND SUBMITTALS SHOP DRAWING SUBMITTALS ARE ONLY REVIEWED FOR GENERAL CONFORMANCE WITH THE INFORMATION SHOWN ON THE CONSTRUCTION DOCUMENTS. THE GENERAL CONTRACTOR MUST REVIEW AND APPROVE THE SHOP DRAWINGS PRIOR TO THEIR SUBMITTAL TO THE ARCHITECT. SUBMITTALS WHICH DO NOT CONTAIN THE CONTRACTOR'S SHOP DRAWING STAMP SHALL BE RETURNED WITHOUT REVIEW. ANY REQUESTED CHANGES TO THE CONTRACT DOCUMENTS SHALL BE COMMUNICATED IN WRITING PRIOR TO SUBMITTING THE SHOP DRAWINGS AND CLOUDED ON THE SHOP DRAWINGS. SHOP DRAWINGS MUST BE SUBMITTED FOR ENGINEER'S REVIEW OF THE FOLLOWING ITEMS: (S/S = SIGNED & SEALED SHOP DRAWING WITH CALCS, SD = SHOP DRAWING FOR REVIEW ONLY) COMPLETE SHOP DRAWINGS FOR CONSTRUCTION OF EACH BUILDING COMPONENT NOT DESIGNED BY THE DESIGN TEAM OF RECORD AND NOT SPECIFIED ON THE PROJECT CONSTRUCTION DOCUMENTS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THE PROJECT AND SHALL BE AVAILABLE AT THE JOB SITE DURING TIMES OF INSPECTION. SOME STRUCTURAL SYSTEMS ARE DEFINED AS VENDOR-DESIGNED COMPONENTS PER THE STRUCTURAL DOCUMENTS. THESE ELEMENTS OF THE DESIGN ARE DEFERRED SUBMITTAL COMPONENTS AND HAVE NOT BEEN PERMITTED UNDER THE BASE BUILDING APPLICATION. VENDOR-DESIGNED COMPONENT SHOP DRAWINGS SHALL BE APPROVED BY THE COMPONENT DESIGNER ENGINEER PRIOR TO CURSORY REVIEW BY THE ENGINEER OF RECORD FOR LOADS IMPOSED ON THE BASE STRUCTURE. THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE CONFORMANCE AND ALL NECESSARY CONNECTIONS NOT SPECIFICALLY CALLED OUT ON ARCHITECTURAL OR STRUCTURAL DRAWINGS. SHOP DRAWINGS SHALL INDICATE MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON BASIC STRUCTURE. THE CONTRACTOR SHALL SUBMIT THE STAMPED COMPONENT SYSTEM DOCUMENTS TO THE BUILDING OFFICIAL FOR APPROVAL. WIRE SPACING PLUS 6" 40 BAR DIAMETERS WELDED WIRE FABRIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REINFORCING BARS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LIVE LOADS: ROOFS AND CANOPIES (REDUCIBLE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STAIRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FLOORS (REDUCIBLE). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIND LOADS: ULTIMATE WIND SPEED: (ASCE 7-16) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NOMINAL WIND SPEED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MEAN ROOF HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RISK CATEGORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIND EXPOSURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ENCLOSURE CLASSIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INTERNAL PRESSURE COEFFICIENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DIRECTIONALITY FACTOR (Kd) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHAPE FACTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W-SHAPES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OTHER SHAPES & PLATES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HSS SQUARE & RECTANGULAR SHAPES . . . . . . . . . . . . . . . . . . . HSS ROUND SHAPES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STEEL PIPES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WELDING ELECTRODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HIGH-STRENGTH BOLTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANCHOR RODS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WELDED STUDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEFORMED BARS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WELDABLE BARS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PAINT & PROTECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GROUT - NONMETALLIC, SHRINKAGE-RESISTANT . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM A992, Fy=50 KSI ASTM A36, Fy=36 KSI ASTM A500 GRADE B, Fy=46 KSI ASTM A500 GRADE B, Fy=42 KSI ASTM A53 GRADE B, Fy=35 KSI AWS A5.1 OR A5.5 SERIES E70 MIN 3/4Ø ASTM A325 GRADE 36 ASTM F1554 ASTM A108 ASTM A496 ASTM A706 SSPC PAINT 25 ASTM C1107 20 PSF 100 PSF 100 PSF 20 PSF 20 PSF DEAD LOADS: FLOOR (SUPERIMPOSED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ROOF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THIS BUILDING IS LOCATED IN THE WIND BORNE DEBRIS REGION. IMPACT RESISTANT GLAZING IS REQUIRED. F'C= 3000 PSI F'C= 3000 PSI F'C= 3000 PSI CONCRETE (DESIGN PER CURRENT EDITION ACI 318): SLAB ON GRADE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FOOTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ALL OTHER CONCRETE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WELDED WIRE FABRIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FOOTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SLABS ON GRADE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FOUNDATION IF FOOTING ELEVATIONS SHOWN OCCUR IN A DISTURBED, UNSTABLE, OR UNSUITABLE SOIL, THE ENGINEER SHALL BE NOTIFIED. 3" 2" FROM TOP CONCRETE UNLESS OTHERWISE NOTED (UON) ON THE DRAWINGS, MINIMUM COVER FOR REINFORCING SHALL BE AS FOLLOWS: ALL REINFORCING SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES IN CONFORMANCE WITH CRSI MANUAL OF STANDARD PRACTICE AND ACI 318 DURING THE PLACING OF THE CONCRETE. UNLESS OTHERWISE NOTED, SPLICES IN REINFORCING, WHERE PERMITTED, SHALL BE AS FOLLOWS: ALL HOOKS IN REINFORCING BARS SHALL BE AN ACI STANDARD HOOK, UNLESS OTHERWISE NOTED. DOWELS FROM FOUNDATIONS OR SLABS TO WALLS SHALL MATCH WALL REINFORCING, UNLESS OTHERWISE NOTED. DOWELS SHALL BE PLACED BEFORE CONCRETE IS POURED. THEY SHALL NOT BE PUSHED INTO THE CONCRETE. SOIL BEARING (ASSUMED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 PSF 4.25 IN/HR N/A RAIN: RAIN INTENSITY, i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RAIN LOAD, R (MAXIMUM LOAD AT PRIMARY DRAIN) . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 55 5 4 4 3 a a a a 3 3 3 1 2e 2e 2r 2e 1 2e 1 2r 1 2r 2e 2e 2r 2r 1 2e12e 3 3 33 1 1 aaa aaa a a 2eo 2eo 3o3o2eo ROOF PLAN (GENERIC BUILDING SHOWN) WALLS (GENERIC BUILDING SHOWN) a=12'-6" + 29.2 - 56.8 - 69.8 - 89.2 + 69.8 + 69.1 - 86.5 - 106.0 -99.8 + 33.8 - 56.8 - 76.0 - 99.0 - 76.0 - 69.1 - 88.3 - 111.3 - 111.3 + 18.4 - 45.3 - 55.3 - 66.6 - 55.3 - 76.8 - 82.4 - 93.6 -72.9 + 18.4 - 45.3 - 49.1 - 56.8 - 49.1 - 76.8 - 80.6 - 88.3 - 61.4 500 SF200 SF 200 SF 100 SF10 SF 10 SF 20 SF POSITIVE ALL ZONES NEGATIVE 1 NEGATIVE 2e NEGATIVE 2r NEGATIVE 3 OVERHANG 1 OVERHANG 2e OVERHANG 2r OVERHANG 3 POSITIVE ZONES 4 & 5 NEGATIVE 4 NEGATIVE 5 ZONE COMPONENT & CLADDING DESIGN WIND PRESSURES (PSF) ROOF WALL NOTES: 1. TABLE PRESSURES ARE FOR THE SQUARE FOOT (SF) TRIBUTARY AREA SHOWN. FOR OTHER TRIBUTARY AREAS, LINEARLY INTERPOLATE BETWEEN VALUES SHOWN ABOVE. 2. POSITIVE PRESSURES ACT TOWARD THE BUILDING. NEGATIVE PRESSURES ACT AWAY FROM THE BUILDING. 3. SEE DIAGRAMS FOR LOCATION OF ZONES. 4. PRESSURES SHOWN ARE ULTIMATE PRESSURES. MULTIPLY VALUES BY 0.6 FOR NOMINAL PRESSURES. + 45.3 - 49.1 - 60.6 + 38.5 - 42.3 - 47.1 + 36.5 - 40.3 - 43.0 + 33.8 - 37.6 - 37.6 100 SFZONE DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS 9133 R.G. Skinner Parkway Jacksonville, Florida 32256 Ph: (904) 483-5200 email: mail@McVeighMangum.com E N G I N E E R I N G · I N C www.McVeighMangum.com Atlanta · Charlotte · Jacksonville · Raleigh CA 6330 Eng. of Record:License No.:7/29/2021 4:05:24 PMBIM 360://200801-Fleet Coleman Remodel/201162 Coleman Bldg at Fleet Landing_STRU_R20.rvt16 APRIL 2021 200801 S001DESIGN CRITERIA & GENERAL NOTES Atlantic BeachFleet LandingColeman RemodelFloridaDesigner 80678Timothy R. Moore NO. DATE DESCRIPTION 1 2 3 4 5 6 A B C D E F PRE-ENGINEERED STEEL MONUMENTAL STAIR EXIST COL TO REMAIN EXIST 2'-0"x1'-0" FTG TO REMAIN REMOVE EXIST WALL & COL TO 8" BELOW SLAB & PATCH EXIST SLAB PER DETAIL 10/S201 EXIST 3'-0"x1'-0" FTG REMOVE EXISTING, SLOPING SLAB AND REPLACE w/ 4" CONCRETE SLAB ON GRADE w/ WWF 6x6 -W1.4xW1.4 ON VAPOR RETARDER AND COMPACTED FILL. T/SLAB EL TO MATCH EXISTING BUILDING SLAB. SEE NOTE 5 SLOPE, SEE ARCH EXIST STEEL COLUMN ON ISOLATED SPREAD FOOTING TO REMAIN, (TYP 2 PLACES) EXIST 12" CMU COL ON THICKENED SLAB FTG TO REMAIN, TYP WHERE SHOWN. SEE DETAIL 3/S201 FOR PARTIAL FTG REMOVAL DETAIL EXIST SLAB AND THICKENED EDGE 3 S201 ____2 S201 ____SLAB JOINTS SEE 1/S201, TYP1/S201 10/S201 FOUNDATION PLAN NOTES: 1) ELEVATIONS ARE BASED ON T/SLAB DATUM EL 0'-0". 2) FOR DESIGN CRITERIA AND GENERAL NOTES, SEE SHEET S001. 3) TOP OF FOOTINGS EL = MATCH EXISTING. 4) FOR DIMENSIONS, SECTIONS & ELEVATIONS NOT SHOWN, SEE ARCH. 5) DENOTES SUPPORT POST FOR PRE-ENGINEERED STAIR. COORDINATE LOCATIONS w/ ARCH AND STAIR MANUF. FOR FOOTING REQUIREMENTS, SEE DETAIL 8/S201. DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS 9133 R.G. Skinner Parkway Jacksonville, Florida 32256 Ph: (904) 483-5200 email: mail@McVeighMangum.com E N G I N E E R I N G · I N C www.McVeighMangum.com Atlanta · Charlotte · Jacksonville · Raleigh CA 6330 Eng. of Record:License No.:7/29/2021 4:05:26 PMBIM 360://200801-Fleet Coleman Remodel/201162 Coleman Bldg at Fleet Landing_STRU_R20.rvt16 APRIL 2021 200801 S100FOUNDATION PLAN Atlantic BeachFleet LandingColeman RemodelFloridaDesigner 80678Timothy R. Moore SCALE: 1/8" = 1'-0"S100 1 FOUNDATION PLAN NO. DATE DESCRIPTION EXIST W21x50EXIST W21x50EXIST W18x35EXIST W24x68EXIST W24x68EXIST W21x62EXIST W24x68EXIST W24x68EXIST W24x68EXIST W24x68(E) W24x162EXIST W12x22EXIST W12x22EXIST W12x19EXIST W12x22 EXIST W24x68EXIST W24x68EXIST W18x40EXIST W16x26 EXISTEXIST W16x26EXIST W21x62EXIST W21x57EXIST W18x35EXIST W21x44EXIST W18x35EXIST W21x62EXIST W12x14 EXIST W12x14 (E) W16x31EXIST W12x19 EXIST W12x19EXIST W12x19EXIST W12x19EXIST W12x19 EXIST W21x44 1 2 3 4 5 6 7 A B C D E F W10x22EXISTW10x22EXIST W18x40EXIST W16x26 8 EQ SPACES16K3EXISTEXISTW16x26W16x26EXISTW10x22EXIST EXIST W8x10 W8x10 C10x25 C8x11.5 C8x11.5 W8x21 14'-0" ATTACH NEW JOISTS TO EXIST CONC BEAM w/ STEEL PLATE ATTACHED w/ EPOXY ANCHORS & STEEL ANGLE SEAT FOR JOIST ATTACH NEW JOISTS TO EXIST CONC BEAM w/ STEEL PLATE ATTACHED w/ EPOXY ANCHORS & STEEL ANGLE SEAT FOR JOIST EXIST BEAM WILL REQUIRE FLANGE REINFORCEMENT BY WELDING CONTINUOUS PLATES ON TO THEM TO CARRY THE ADDED LOAD OF THE STAIR, SEE DETAIL 5/S201. CHANNEL FRAMING SHOWN IS TO BE WELDED TO EXIST JOISTS. SHORE UP JOISTS BEFORE CUTTING THEM AND WELDING THE FRAMING, SEE SECTION 9/S201.EXIST STEEL FLOOR JOISTS (TYP UON)EXIST W12x22 EXIST W16x26 EXIST W12x22 EXIST W12x22 EXIST W12x22 EXIST W21x50EXIST W21x50EXIST W21x50EXIST W18x405/S201 EXIST 2-2x12 EXIST 2-2x12 EXIST 2-2x12 EXIST 2-2x12 EXIST 2-2x12 EXIST 2-2x12 @ 2'-0" OC EXIST WOOD ROOF TRUSSES EXIST WOOD ROOF TRUSSES @ 2'-0" OC EXIST WOOD ROOF TRUSSES @ 2'-0" OC 4 S201 ____ 7 S201 ____6 S201 ____EXIST W18x35L6x6x5/16 EXIST W21x623" CONC SLAB ON 9/16" 28GA METAL FORM DECK 9 S201 ____ 3" CONC SLAB ON 9/16" 28GA METAL FORM DECK 2 S301 ____ 3 S301 ____ 9/S201 PRE-ENGINEERED STEEL MONUMENTAL STAIR 4 S301 ____ 5 S301 ____ C8x11.5 (LO) W8x21 W8x21 C5x6.7 (HI) C5x6.7 C5x6.7 (HI) PROVIDE NEW, FIELD WELDED SHEAR TAB IN EXISTING BEAM WEB FOR NEW BEAM ATTACHMENT PER DETAIL 1/S301 (TYP) 4 S201 ____ 13 S201 ____ FLOOR FRAMING PLAN NOTES: 1) ELEVATIONS ARE BASED ON T/SLAB DATUM EL 0'-0". 2) TOP OF STEEL (T/STL) ELEVATION, SEE SECTIONS. 3) FOR DESIGN CRITERIA AND GENERAL NOTES, SEE SHEET S001. 4) FOR BEAM TO BEAM & BEAM TO COLUMN CONNECTIONS, SEE DETAIL 1/S301. 5) SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS, SECTIONS & ELEVATIONS NOT SHOWN. 1/S301 DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS 9133 R.G. Skinner Parkway Jacksonville, Florida 32256 Ph: (904) 483-5200 email: mail@McVeighMangum.com E N G I N E E R I N G · I N C www.McVeighMangum.com Atlanta · Charlotte · Jacksonville · Raleigh CA 6330 Eng. of Record:License No.:7/29/2021 4:05:29 PMBIM 360://200801-Fleet Coleman Remodel/201162 Coleman Bldg at Fleet Landing_STRU_R20.rvt16 APRIL 2021 200801 S1012ND FLOOR FRAMING PLAN Atlantic BeachFleet LandingColeman RemodelFloridaDesigner 80678Timothy R. Moore SCALE: 1/8" = 1'-0"S101 1 2ND FLOOR FRAMING PLAN NO. DATE DESCRIPTION 1 2 3 4 5 6 7 A B C D E F EXIST W12x22EXIST W12x19EXIST W12x19 EXIST W12x22 EXIST W12x22 EXIST W12x22 EXIST W12x19 EXIST W12x19EXIST W12x19GIRDER TRUSSGIRDER TRUSSGIRDER TRUSSGIRDER TRUSS EXIST W16x31 GIRDER TRUSS GIRDER TRUSSEXIST TIMBER EXIST TIMBER EXIST TIMBEREXIST TIMBEREXIST TIMBEREXIST TIMBERGIRDER TRUSSGIRDER TRUSSEXIST TIMBEREXIST TIMBERGIRDER TRUSSEXIST TIMBERGIRDER TRUSSGIRDER TRUSSGIRDER TRUSS EXIST TIMBER EXIST TIMBER EXIST TIMBER ROOF TRUSSES @ 2'-0" OC EXISTING PRE-ENGINEERED WOOD ROOF TRUSSES @ 2'-0" OCEXISTING PRE-ENGINEERED WOODGIRDER TRUSSEXIST TIMBERGIRDER TRUSS EXIST TIMBER EXIST W16x31EXIST W16x31EXIST W16x31 ____________ S102 2W12x19W12x14W12x14W12x14W12x19HOOD OVER EXHIBITION KITCHEN, SEE ARCH AND MECH. COORD T/STEEL FRAMING EL w/ ARCH & HOOD REQUIREMENTS. SEE SECTION 7/S301. ____________ S102 4____________ S102 3 9"9"6"W12x19 W12x14W12x14W12x14 BEAMS TO BE CENTERED ON HOOD CONNECTIONS BELOW. CONTRACTOR COORDINATE w/ EQUIPMENT PURCHACED 8 S301 ____ 7 S301 ____ 6 S301 ____ 6 S301 ____ SIM PROVIDE NEW, FIELD WELDED SHEAR TAB IN EXISTING BEAM WEB FOR NEW BEAM ATTACHMENT PER DETAIL 1/S301 (TYP) ____________ S301 9 ____________ S301 9 OPP 4x12 WOOD BEAM 4x12 WOOD BEAM BEAMS BETWEEN ROOF TRUSSES TO SUPPORT OP WALL TRACK BELOW, SEE NOTE 6 W12x19EXIST EXISTEXISTW8x10W8x1011 S201 ____ 11 S201 ____ FOR DUCT AND SCREEN SUPPORT UNDER TRUSSES, SEE DETAIL 11/S301 3 4 C D EXIST W12x16 EXIST W12x16EXIST W12x16EXIST W12x16 PROVIDE STEEL TO SUPPORT 500# POINT LOAD FROM HUNG SCULPTURE W10x12 10 S301 ____ 1/S301 ROOF FRAMING PLAN NOTES: 1. ELEVATIONS ARE BASED ON TOP OF SLAB ON GRADE DATUM 0'-0". 2. TOP OF STEEL (T/STL) ELEVATION, SEE SECTIONS. 3. FOR DESIGN CRITERIA AND GENERAL NOTES, SEE SHEET S001. 4. FOR BEAM TO BEAM & BEAM TO COLUMN CONNECTION, SEE DETAIL 1/S301. 5. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS, SECTIONS, AND ELEVATIONS NOT SHOWN. 6. ATTACH EACH END OF BEAM TO EXISTING GIRDER TRUSS W/ SIMPSON HU46 HANGER W/ 6-10d INTO BEAM AND 12-16d INTO GIRDER TRUSS BOTTOM CHORD. PROVIDE 45º SKEWED HANGER AT ONE END. IF ATTACHMENT POINT IS NOT WITHIN 6" OF A TRUSS WEB CONNECTION POINT, PROVIDE THE REQUIREMENTS OF DETAIL 12/S201.12/S201 2 3 C D 4 5 C D DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS 9133 R.G. Skinner Parkway Jacksonville, Florida 32256 Ph: (904) 483-5200 email: mail@McVeighMangum.com E N G I N E E R I N G · I N C www.McVeighMangum.com Atlanta · Charlotte · Jacksonville · Raleigh CA 6330 Eng. of Record:License No.:7/29/2021 4:05:32 PMBIM 360://200801-Fleet Coleman Remodel/201162 Coleman Bldg at Fleet Landing_STRU_R20.rvt16 APRIL 2021 200801 S102ROOF FRAMING PLAN Atlantic BeachFleet LandingColeman RemodelFloridaDesigner 80678Timothy R. Moore SCALE: 1/8" = 1'-0"S102 1 ROOF FRAMING PLAN SCALE: 1/8" = 1'-0"S102 2 HIGH ROOF FRAMING PLAN SCALE: 1/8" = 1'-0"S102 3 MEZZ FRAMING PLAN SCALE: 1/8" = 1'-0"S102 4 MEZZ FRAMING PLAN NO. DATE DESCRIPTION CONT PL 1/2"x1-3/4" REINFORCEMENT STRIP EXIST W18 BEAM, SEE PLAN CONT PL 1/2"x1-3/4" REINFORCEMENT STRIP 3/16 2@12 4" @ EACH END 3/16 2@12 4" @ EACH END EXIST SLAB AND EDGE ANGLE EXIST STEEL BEAM, SEE PLAN. SEE DETAIL 5/S201 FOR REINFORCEMENTS STEEL BEAM, SEE PLAN PERPINDICULAR STEEL FRAMING, SEE PLAN CONCRETE SLAB ON METAL DECK, SEE PLAN 3/8" STIFNER PLATES NS/FS ALIGNED w/ BEAM FLANGE ABOVE 3/8" STIFNER PLATES EACH SIDE ALIGNED w/ EDGE OF BEAM FLANGES BELOW, TYP 4 PLACES. INSTALL REINFORCEMENTS BEFORE STIFNER PLATES 3/16 3/16 FOR CONNECTION, SEE DETAIL 1/S301. STEEL BEAM, SEE PLAN EXIST STEEL JOIST BEYOND CONT. L3x3x1/4" EDGE ANGLE STEEL BEAM, SEE PLAN BEAM, SEE PLAN FOR CONNECTION, SEE DETAIL 1/S301 HSS3x3x1/4 TUBE HANGER 3/16 ATTACH BRACE TO BEAM w/ 2-SDS25600 SCREWS EXIST WOOD BEAM, SEE PLAN EXIST ROOF TRUSS, SEE PLAN GLAZING, SEE ARCH 2x4 BRACE @ EACH EXIST TRUSS ATTACH MULLION TO BEAM w/ VERTICAL SLIP CLIP CONNECTION BY MANUFACTURER 5-10d NAILS STOP REINF (IF REQ'D) EA SIDE OF JOINT PREMOLDED EXP JOINT MATERIAL CRACK CONTROL JOINT CONSTRUCTION JOINT EXPANSION JOINT @ WALL NOTES: 1. USE CONSTRUCTION JOINT INSTEAD OF CRACK CONTROL JOINT WHEREVER CONSTRUCTION IS STOPPED OR WHERE CALLED FOR ON PLAN."T"/21/8" CONTROL JOINT "T"/4"T"CONT VAPOR RETARDER, TYP BREAK BOND w/ CURING COMPOUND"T"1/2" SAW CUT JOINT, CUT BETWEEN 4 & 12 HOURS AFTER CONC IS PLACED PROVIDE FULL DEPTH BULKHEAD HELD FIRMLY IN A VERTICAL POSITION WWF, SEE PLAN (1) #4 TOP (2) #4 CONT w/ #3 @ 36" TRANSV1'-4"1'-0"SEE PLANT/SLAB EL, MATCH EXIST 12" MINGLAZING, SEE ARCH ATTACHMENT TO CONCRETE BY MANUFACTURER EXIST THICKENED SLAB EDGE FTG #4 DOWEL @ 24" OC, 12" LG w/ STD HK. EMBED 6". INSTALL w/ EPOXY PER GEN NOTES T/EXIST SLAB EL 8"x8" THICKENED SLAB EDGE w/ 1-#4 CONT EXISTING SLOPING SLAB TO BE REMOVED 3"EXIST 2'-0"x2'-0" THICKENED SLAB FOOTING NEW CONCRETE SLAB, SEE PLAN CUT AND REMOVE TOP OF EXISTING THICKENED SLAB FOOTING FOR DEPTH SHOWN CUT AROUND COLUMN EXISTING 12" CMU COLUMN #4 CONT ____________ S201 2 #4 DOWEL W/ 8" HOR LEG AND 6" EMBED W/ HOR LEG CTRD IN NEW SLAB. TYP 4 PLACES. INSTALL W/ EPOXY PER GEN NOTES 1'-0"2'-6" x 2'-6"3" CLR T/FTG EL = T/EXIST SLAB EL POST & FTG CL EXIST CONC SLAB CUT & REMOVE EXIST SLAB TO INSTALL NEW CONC FTG FOR STAIR SUPPORT POST 3-#5 EW BOT CONNECTION OF STAIR POST BY STAIR MANUF STAIR SUPPORT POST, SEE PLAN EXIST STEEL JOIST, SEE PLAN STEEL BEAM, SEE PLAN 3/16 1 1/2 @ 48" MAX 3/16 1 1/2 @ EACH DIAGNAL EXIST SLAB #3 BAR @ 24" OC, 30" LG EMBED 6". INSTALL w/ EPOXY PER GEN NOTES T/EXIST SLAB EL 6" COMPACTED SOIL TO 95% MODIFIED PROCTOR DENSITY CONT #3 BAR @ 12" OC EXIST ROOF SHEATHING EXIST ROOF TRUSS EXIST STEEL BEAM EXIST WOOD NAILER GLAZING, SEE ARCH ATTACH MULLION TO BEAM w/ VERTICAL SLIP CLIP CONNECTION BY MANUFACTURER EXISTING TRUSS TOP CHORD EXIST TRUSS WEB MEMBERS EXIST TRUSS BOTTOM CHORD OP WALL BEAM AND HANGER, SEE PLAN ADDED 2x6 SUPPORTS (#2 SYP). ATTACH EACH END TO EXIST w/ 2-SDS25300 SCREWS EXIST TRUSS WEB MEMBERS EXISTING ROOF TRUSS 2x4 BLOCKING BETWEEN EXISTING TRUSSES. ATTACH w/ 4-10d TOENAILS EACH END GLAZING, SEE ARCH ATTACH MULLION TO BEAM w/ VERTICAL SLIP CLIP CONNECTION BY MANUFACTURER EXISTING ROOF TRUSS 2x4 BLOCKING BETWEEN EXISTING TRUSSES. ATTACH w/ 4-10d TOENAILS EACH END 2x6 BRACE AT EACH END OF WALL AND @ 4'-0" OC MAX 6-10d, TYP DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS 9133 R.G. Skinner Parkway Jacksonville, Florida 32256 Ph: (904) 483-5200 email: mail@McVeighMangum.com E N G I N E E R I N G · I N C www.McVeighMangum.com Atlanta · Charlotte · Jacksonville · Raleigh CA 6330 Eng. of Record:License No.:7/29/2021 4:05:33 PMBIM 360://200801-Fleet Coleman Remodel/201162 Coleman Bldg at Fleet Landing_STRU_R20.rvt16 APRIL 2021 200801 S201SPORTS BAR, DUMB WAITER, AND STAIR SECTIONS Atlantic BeachFleet LandingColeman RemodelFloridaDesigner 80678Timothy R. Moore SCALE: NTSS201 5 REINFORCEMENT OF EXIST BEAM SCALE: NTSS201 6 2ND FLOOR LANDING SECTION SCALE: NTSS201 7 BACK OF CANTILEVER CONNECTION SCALE: NTSS201 4 SECTION SCALE: NTSS201 1 TYP SLAB ON GRADE JOINTS SCALE: NTSS201 2 TYPICAL TURNDOWN SCALE: NTSS201 3 SECTION AT EXISTING TE FOOTING SCALE: NTSS201 8 STAIR POST FOOTING DETAIL SCALE: NTSS201 9 DUMB WAITER FRAMING SCALE: NTSS201 10 NEW TO EXISTING SLAB TIE IN NO. DATE DESCRIPTION SCALE: NTSS201 11 SECTION AT 2ND FLOOR EXTENSION SCALE: NTSS201 12 OP WALL BEAM SUPPORT SCALE: NTSS201 13 WALL BRACE DETAIL A A B B SINGLE PLATE CONN CONNECTION TABLE CL SUPPORTED BEAM MAX 3" 4"3"3 1/2" MAX 2 1/2" MAX 2 3/4" 4" 3 1/2" SUPPORTING MEMBER EDGE PL 5/16" CONNECTION ANGLE OR PL CONNECTION TYPE SUPPORTED BEAM 1. 2. 3. 4. 5. 6. 7. CONN TYPE SINGLE PLATE CONNECTION MINIMUM SUPPORTED MEMBER SIZEDOUBLE ANGLESIZE SIZE LENGTHLENGTH FACTORED LOAD CAPACITY SINGLE ANGLE SINGLE PLATE NOTES: 1. CONNECTION BOLTS SHALL BE 3/4"Ø A325-N BEARING TYPE. BOLT LIMIT STATE IN SINGLE SHEAR = 17.9 KIPS. 2. CONNECTION ANGLE THICKNESS: 5/16" FOR DOUBLE ANGLE CONNECTIONS TYPE 2 THRU 7. 3/8" FOR SINGLE ANGLE CONNECTIONS TYPE 2 THRU 7. 3. SINGLE PLATE CONNECTIONS ARE BASED ON FLEXIBLE CONNECTIONS WITH STANDARD HOLES. 4. ANY CONNECTION THAT IS OUTSIDE THE LIMITS OF THE CONNECTION TABLE SHALL BE DESIGNED BY THE SPECIALTY ENGINEER LICENSED IN THE STATE OF PROJECT AND SHALL BE SUBMITTED AS SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL. 5. ALL CONNECTIONS WITH AXIAL LOADS SHOWN ON PLAN SHALL BE DESIGNED BY THE SPECIALTY ENGINEER LICENSED IN THE STATE OF THE PROJECT AND SHALL BE SUBMITTED AS SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL. 6. BOLTED/WELDED SINGLE AND DOUBLE ANGLE CONNECTIONS MAY BE USED PROVIDED THAT THE WELDS ARE SIZED TO RESIST THE LOADS SHOWN IN ACCORDANCE WITH AISC STANDARDS. DOUBLE & SINGLE ANGLE CONNECTION 7 L4x3 1/2 L4x3 1/2 L4x3 1/2 L4x3 1/2 L4x3 1/2 L4x3 1/2 L6x4x3/8 6 5 4 3 2 1 1' - 8 1/2" 1' - 5 1/2" 1' - 2 1/2" 11 1/2" 8 1/2" 5 1/2" 2 1/2" PL 5/16"x4" PL 5/16"x4" PL 5/16"x4" PL 5/16"x4" PL 5/16"x4" PL 5/16"x4" - - 217k 112k 108k 89k 81k 62k 39k 23k - - 93k 74k 55k 35k 18k 176k 112k 64k 39k 23k 16k W36, W33 W30, W27 W24, W21 W18, W16 C6, WT W10, C10, W8, C8 W14, C15, W12, C12 2 1/2" 4"1 1/4"1 1/4"3" SPACINGMAX 2 1/2" WEB FACE OF SUPPORTING MEMBER 2 1/2"2 1/2"2 1/2" (TYP) 1/4 1 3/4"TYP 3" SPACINGMIN 1 1/4"TYP ALL SINGLE PL CONN TYPES SECTION A-A BOLTED DOUBLE ANGLE CONN SECTION B-B BOLTED SINGLE ANGLE CONN3"WEB FACE OF SUPPORTING MEMBER CL SUPPORTED BEAM 1' - 8 1/2" 1' - 5 1/2" 1' - 2 1/2" 11 1/2" 8 1/2" 5 1/2" CONC FLOOR ON METAL DECK, SEE PLAN STEEL JOIST, SEE PLAN 1/8 T/JOIST EL, SEE PLAN T/SLAB EL, (MATCH EXIST) CONT L3x3x1/4 1/8 2 L6x4x7/16 (LLV)x1'-0" LG 2-3/4" EPOXY ANCHORS w/ 6" MIN EMBED ELEV SHAFT EXIST MASONRY WALL EXIST 20" MASONRY BEAM CONC FLOOR ON METAL DECK, SEE PLAN STEEL JOIST, SEE PLAN 1/8 T/JOIST EL, SEE PLAN T/SLAB EL, (MATCH EXIST) CONT L3x3x1/4 1/8 2 L6x4x7/16 (LLV)x1'-0" LG 2-3/4" EPOXY ANCHORS w/ 6" MIN EMBED EXIST MASONRY WALL EXIST 20" MASONRY BEAM CONC FLOOR ON METAL DECK, SEE PLAN EXIST STEEL JOIST EXIST STEEL JOIST 3/16 2@12 SEE NOTE 1 CONT L4x4x1/4" NEW SLAB & METAL DECK, SEE PLAN EXIST CONC SLAB STEEL JOIST, SEE PLAN NOTES: 1) AT CONTRACTOR OPTION, ANGLE MAY BE OMITED IF EXISTING SLAB IS CUT BACK 1.5" ONTO EXISTING JOIST FOR NEW DECK BEARING. EXIST STEEL BEAM EXIST CONC SLAB SEE NOTE 1 NOTE: 1) CUT EXISTING DECK BACK OVER EXISTING BEAM FLANGE FOR DISTANCE SHOWN. 2 1/2" BEAM, ANGLE, & CONNECTION CL CONNECTION ROD BY STATUE MANUF L3x3x1/4"x0'-6" LG 3/8" STIFNER PLATES NS/FS CTRD ON VERT ANGLE LEG 3/16 STEEL BEAM, SEE PLAN BEAM, ANGLE, & CONNECTION CL CONNECTION ROD BY HOOD MANUF L3x3x1/4"x0'-6" LG 3/8" STIFNER PLATES NS/FS CTRD ON VERT ANGLE LEG 3/16 STEEL BEAM, SEE PLAN EQ EQ AT SIM WHERE TWO CONN RODS ARE REQUIRED, PROVIDE AS SHOWN. INCREASE ANGLE LENGTH AS NEEDED BEAM CL 3/8" STIFNER PLATES 3/8" STIFNER PLATE STEEL BEAM, SEE PLAN BEAM CL T/SCREEN EL, SEE ARCH T/STEEL EL 4"PRE-ENGINEERED CUSTOM STEEL TUBE & GLASS SCREEN, SEE ARCH. ATTACHMENT AT T&B FLANGE OF BEAM BY MANUF L2x2x1/4x-BRACING @ 5'-0" OC MAX STEEL BEAM, SEE PLAN COL BEYOND CL SEE PLAN BEAM CL CONNECTION ROD BY HOOD MANUF MC8x18.7 3/8" STIFNER PLATE 3/16 STEEL BEAM, SEE PLAN FOR CONNECTION, SEE DETAIL 1/S301. CONNECTION CL w/ EQUIP PURCHACED CONTRACTOR COORD EQ EQ 3/16 2" CL BEAM 3/16 CL BEAM CL COL CL COL SEE PLANSEE PLAN L4x4x5/16x8 1/2" LG CONNECTION ANGLE. SEE CONN TYPE 3 FROM 1/S301 FOR REMAINDER OF CONNECTION INFO STEEL BEAM, SEE PLAN FOR CONNECTION, SEE 1/S301 STEEL BEAM, SEE PLAN EXISTING W8x31 STEEL COLUMN 2-10d @ EACH BEARING LOCATION, TYP CONT 2x8 RUNNING FLAT ALLONG TOP OF TRUSS BOT CHORDS EXISTING ROOF TRUSS BOTTOM CHORD 1/2" ALL THREAD ROD FOR DUCT AND SCREEN ATTACHMENT. MAX SPACING = 24" MAX LOAD = 300# DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS 9133 R.G. Skinner Parkway Jacksonville, Florida 32256 Ph: (904) 483-5200 email: mail@McVeighMangum.com E N G I N E E R I N G · I N C www.McVeighMangum.com Atlanta · Charlotte · Jacksonville · Raleigh CA 6330 Eng. of Record:License No.:7/29/2021 4:05:35 PMBIM 360://200801-Fleet Coleman Remodel/201162 Coleman Bldg at Fleet Landing_STRU_R20.rvt16 APRIL 2021 200801 S301HOOD, STATUE SUPPORT AND ELEVATOR LOBBY SECTIONS Atlantic BeachFleet LandingColeman RemodelFloridaDesigner 80678Timothy R. Moore SCALE: NTSS301 1 BEAM TO GIRDER & COLUMN CONNECTIONS SCALE: NTSS301 2 FLOOR ATTACHMENT AT ELEVATOR SCALE: NTSS301 3 FLOOR ATTACHMENT AT CMU WALL SCALE: NTSS301 4 DECK SPLICE AT EXISTING JOIST SCALE: NTSS301 5 DECK SPLICE AT EXISTING BEAM SCALE: NTSS301 10 STATUE SUPPORT SECTION SCALE: NTSS301 6 TYPICAL HOOD SUPPORT SECTION SCALE: NTSS301 7 SCREEN SECTION SCALE: NTSS301 8 EXTENDED HOOD SUPPORT SECTION SCALE: NTSS301 9 PLAN VIEW OF CONNECTION NO. DATE DESCRIPTION SCALE: NTSS301 11 SUPPORT AT EXISTING TRUSSES