1 FLEET LANDING Coleman Bldg Reno COMM21-0042 Electrical COMcheck_1COMcheck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project Title:
2018 IECC
Project Type:Alteration
Construction Site:Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Fleet Coleman Remodel
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed
Watts
1-Total building area (Dining: Bar Lounge/Leisure)31652 0.90 28487
28487Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixture
Total building area (Dining: Bar Lounge/Leisure, 31652 sq.ft.)
LED: A1: 1X4 FLAT PANEL: LED Panel 44W:1 10 45 450
LED: A3: 2X4 FLAT PANEL: LED Panel 19W:1 44 39 1716
LED: AC: 2X2 FLAT PANEL: LED Panel 19W:1 4 41 164
LED: B1: MULTI HEAD RETAIL: LED A Lamp 2.5W:1 8 55 440
LED: B2: LINEAR: LED Linear 8W:1 4 14 56
LED: C1: 8" CYLINDER: LED MR 2W:1 4 75 300
LED: C2: 4" CYLINDER: LED MR 2W:1 18 21 378
LED: C3: 4" CYLINDER: LED MR 2W:1 8 27 216
LED: F4: STRIP: LED Linear 8W:1 23 37 851
LED: HA4: 4" DOWNLIGHT: LED MR 2W:1 73 12 876
LED: HB4: 4" DOWNLIGHT: LED MR 2W:1 97 13 1261
LED: HC4: 4" DOWNLIGHT: LED MR 2W:1 11 23 253
LED: K2: 2X4 TROFFER: LED Panel 19W:1 13 34 442
LED: KA: 2X2 TROFFER: LED Panel 19W:1 41 30 1230
LED: KC: 2X2 TROFFER: LED Panel 19W:1 5 37 185
LED: L4A: 4' LINEAR: LED Panel 19W:1 6 18 108
LED: L4B: 4' LINEAR: LED Linear 8W:1 25 36 900
LED: L4W: 4' LINEAR: LED Linear 8W:1 1 36 36
LED: L6A: 6' LINEAR: LED Linear 8W:1 25 27 675
LED: L6C: 6' LINEAR: LED Linear 8W:1 2 53 106
LED: L8A: 8' LINEAR: LED Linear 8W:1 26 36 936
LED: L22: 2' LINEAR: LED Linear 8W:1 10 19 190
LED: L33: 3' LINEAR: LED Linear 8W:1 7 28 196
LED: S1: SMALL PENDANT: LED Other Fixture Unit 6.5W:1 3 13 39
LED: S2: SEMI-FLUSH MOUNT: LED Other Fixture Unit 6.5W:1 3 24 72
LED: S3: WALL SCONCE: LED Other Fixture Unit 6.5W:1 4 16 64
Project Title:
Data filename:
Fleet Coleman Remodel 08/04/21Report date:
61 ofPage
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixture
LED: S4: PENDANT: LED Other Fixture Unit 6.5W:1 1 96 96
LED: S5: SMALL PENDANT: LED Other Fixture Unit 6.5W:1 1 9 9
LED: S6: CHANELIER: LED Other Fixture Unit 6.5W:1 1 72 72
LED: S8: SEMI FLUSH: LED Other Fixture Unit 6.5W:1 3 240 720
LED: S9: WALL SCONCE: LED Other Fixture Unit 6.5W:1 2 10 20
LED: S10: WALL SCONCE: LED Other Fixture Unit 6.5W:1 2 24 48
LED: S11: CHANDELIER: LED Other Fixture Unit 6.5W:1 1 64 64
LED: S12: PENDANT: LED Other Fixture Unit 6.5W:1 1 60 60
LED: S13: CHANDELIER: LED Other Fixture Unit 6.5W:6 1 8 8
LED: S14: CIRCLE PENDANT: LED Other Fixture Unit 6.5W:1 3 112 336
LED: S15: CIRCLE PENDANT: LED Other Fixture Unit 6.5W:1 1 270 270
LED: S16: CHANDELIER: LED Other Fixture Unit 6.5W:8 3 8 24
LED: S17: CHANDELIER: LED Other Fixture Unit 6.5W:6 6 15 90
LED: S18: SEMI FLUSH MOUNT: LED Other Fixture Unit 6.5W:6 4 10 40
LED: S21: WALL SCONCE: LED Other Fixture Unit 6.5W:1 2 8 16
LED: S22: WALL SCONCE: LED Other Fixture Unit 6.5W:1 3 24 72
14085Total Proposed Watts =
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES
Project Title:
Data filename:
Fleet Coleman Remodel 08/04/21Report date:
62 ofPage
Inspection Checklist
Requirements: 100.0% were addressed directly in the COMcheck software
COMcheck Software Version COMcheckWeb
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2018 IECC
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR4]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the interior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Fleet Coleman Remodel 08/04/21Report date:
63 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.2.
2
[EL22]1
Spaces required to have light-
reduction controls have a manual
control that allows the occupant to
reduce the connected lighting load in
a reasonably uniform illumination
pattern >= 50 percent.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.1,
C405.2.1.
1
[EL18]1
Occupancy sensors installed in
classrooms/lecture/training rooms,
conference/meeting/multipurpose
rooms, copy/print rooms,
lounges/breakrooms, enclosed offices,
open plan office areas, restrooms,
storage rooms, locker rooms,
warehouse storage areas, and other
spaces <= 300 sqft that are enclosed
by floor-to-ceiling height partitions.
Reference section language
C405.2.1.2 for control function in
warehouses and section C405.2.1.3
for open plan office spaces.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.1.
2
[EL19]1
Occupancy sensors control function in
warehouses: In warehouses, the
lighting in aisleways and open areas is
controlled with occupant sensors that
automatically reduce lighting power
by 50% or more when the areas are
unoccupied. The occupant sensors
control lighting in each aisleway
independently and do not control
lighting beyond the aisleway being
controlled by the sensor.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.1.
3
[EL20]1
Occupant sensor control function in
open plan office areas: Occupant
sensor controls in open office spaces
>= 300 sq.ft. have controls 1)
configured so that general lighting can
be controlled separately in control
zones with floor areas <= 600 sq.ft.
within the space, 2) automatically turn
off general lighting in all control zones
within 20 minutes after all occupants
have left the space, 3) are configured
so that general lighting power in each
control zone is reduced by >= 80% of
the full zone general lighting power
within 20 minutes of all occupants
leaving that control zone, and 4) are
configured such that any daylight
responsive control will activate space
general lighting or control zone
general lighting only when occupancy
for the same area is detected.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.2,
C405.2.2.
1,
C405.2.2.
2
[EL21]2
Each area not served by occupancy
sensors (per C405.2.1) have time-
switch controls and functions detailed
in sections C405.2.2.1 and C405.2.2.2.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Fleet Coleman Remodel 08/04/21Report date:
64 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.3,
C405.2.3.
1,
C405.2.3.
2
[EL23]2
Daylight zones provided with
individual controls that control the
lights independent of general area
lighting. See code section C405.2.3
Daylight-responsive controls for
applicable spaces, C405.2.3.1 Daylight
responsive control function and
section C405.2.3.2 Sidelit zone.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.4
[EL26]1
Separate lighting control devices for
specific uses installed per approved
lighting plans.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.4
[EL27]1
Additional interior lighting power
allowed for special functions per the
approved lighting plans and is
automatically controlled and
separated from general lighting.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.3
[EL6]1
Exit signs do not exceed 5 watts per
face.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.6
[EL26]2
Low-voltage dry-type distribution
electric transformers meet the
minimum efficiency requirements of
Table C405.6.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.7
[EL27]2
Electric motors meet the minimum
efficiency requirements of Tables
C405.7(1) through C405.7(4).
Efficiency verified through certification
under an approved certification
program or the equipment efficiency
ratings shall be provided by motor
manufacturer (where certification
programs do not exist).
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.8.2,
C405.8.2.
1
[EL28]2
Escalators and moving walks comply
with ASME A17.1/CSA B44 and have
automatic controls configured to
reduce speed to the minimum
permitted speed in accordance with
ASME A17.1/CSA B44 or applicable
local code when not conveying
passengers.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.9
[EL29]2
Total voltage drop across the
combination of feeders and branch
circuits <= 5%.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Fleet Coleman Remodel 08/04/21Report date:
65 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C303.3,
C408.2.5.
2
[FI17]3
Furnished O&M instructions for
systems and equipment to the
building owner or designated
representative.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.4.1
[FI18]1
Interior installed lamp and fixture
lighting power is consistent with what
is shown on the approved lighting
plans, demonstrating proposed watts
are less than or equal to allowed
watts.
Complies
Does Not
Not Observable
Not Applicable
See the Interior Lighting fixture schedule for values.
C408.1.1
[FI57]1
Building operations and maintenance
documents will be provided to the
owner. Documents will cover
manufacturers' information,
specifications, programming
procedures and means of illustrating
to owner how building, equipment and
systems are intended to be installed,
maintained, and operated.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.2.5.
1
[FI16]3
Furnished as-built drawings for
electric power systems within 90 days
of system acceptance.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.3
[FI33]1
Lighting systems have been tested to
ensure proper calibration, adjustment,
programming, and operation.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Fleet Coleman Remodel 08/04/21Report date:
66 ofPage