1 FLEET LANDING Coleman Bldg Reno COMM21-0042 -MECH permit set_1SHEET PRINTED ON:FILE PATH:DATE: 1414 UNDERWOOD AVE. WAUWATOSA, WI 53213 414.431.3131 TEL 414.431.0531 FAX WWW.AGARCH.COM AG PROJECT NUMBER: SHEET INDEX OWNER DEVELOPMENT CONSULTANT Clark Advisory Services 1015 Atlantic Boulevard Atlantic Beach, FL 32233 904.834.9373 407.235.8053 (C) One Fleet Landing Boulevard Atlantic Beach, FL 32233 Fleet Landing FOOD SERVICE CONSULTANT Scopos Hospitality Group 300 West Chestnut Street, Suite 201 Ephrata, PA 17522 717.733.5810 INTERIOR DESIGN Studio 121 Inc. 2305 Kline Ave Suite 100 Nashville, TN 37211 615.469.4121 615.469.6121 (fax) STRUCTURAL CONSULTANT McVeigh & Mangum Engineering, Inc 9133 RG Skinner Pkwy Jacksonville, FL 62256 904.438.5200 MEP CONSULTANT Professional Engineering Consultants 303 South Topeka Wichita, KS 67202 (316) 206-1456 PERMIT SET 8/5/2021 7:41:53 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvtAtlantic Beach, Florida Coleman Remodel 6 AUG 2021 200801 SHEET LIST MP001 MECHANICAL COVER SHEET M101 1/8" FIRST FLOOR DEMO PLAN - HVAC M102 1/8" SECOND FLOOR DEMO PLAN - HVAC M103 1/8" ROOF DEMO PLAN - HVAC M201 1/8" FIRST FLOOR PLAN - HVAC M202 1/8" SECOND FLOOR PLAN - HVAC M203 1/8" FIRST FLOOR PLAN - HYDRONICS M204 1/8" SECOND FLOOR PLAN - HYDRONICS M205 1/8" ROOF PLAN - HVAC M300 1/2" ENLARGED CHILLER PLAN MT100 HVAC SCHEDULES MT102 HVAC SCHEDULES MT103 HVAC SCHEDULES MT200 HVAC DETAILS MT201 HVAC DETAILS MT300 HVAC CONTROLS MT301 HVAC CONTROLS P101 1/8" FIRST FLOOR DEMO PLAN - PLUMBING P102 1/8" SECOND FLOOR DEMO PLAN - PLUMBING P200 1/8" FIRST FLOOR PLAN - UNDERGROUND PLUMBING P201 1/8" FIRST FLOOR PLAN - PLUMBING P202 1/8" SECOND FLOOR PLAN - PLUMBING P300 1/4" ENALRGED PLANS - PLUMBING P400 PLUMBING RISER DIAGRAMS P401 PLUMBING RISER DIAGRAMS PT100 PLUMBING SCHEDULES AND DETAILS SHEET NUMBER WHERE DRAWN SECTION LETTER SECTIONS DETAILS FT-1 TYPICAL EQUIPMENT NUMBER UNIQUE I.D. (FAN TERMINAL NO. 1) EQUIPMENT TYPE (FT=FAN TERMINAL) DRAWING SYMBOLS GENERAL NOTES GENERAL DEMOLITION NOTES B M2.1 M3.6 M3.6 B 5 M2.1 M3.6 5 M3.6 1. VERIFY JOB SITE CONDITIONS AND DIMENSIONS BEFORE BEGINNING WORK. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. 2. NO PIPING, DUCTWORK, ETC. SHALL PENETRATE STRUCTURAL MEMBERS. 3. PROVIDE MISCELLANEOUS CUTTING, PATCHING AND REPAIRING OF FINISHES, ROOF, WALLS, ETC., AS REQUIRED TO ACCOMMODATE THE NEW WORK. 4. G.C. IS TO PATCH ANY OPENINGS IN CORRIDORS REQUIRED TO BE CONSTRUCTED TO LIMIT THE TRANSFER OF SMOKE AND IN SMOKE BARRIERS AS REQUIRED TO MEET CODE REQUIREMENTS. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS. 5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY EXACT LOCATION, CONFIGURATION AND ROUTING OF EXISTING SYSTEMS REQUIRED TO REMAIN IN OPERATION DURING THE PROJECT TO PREVENT DAMAGE DURING DEMOLITION AND PHASING. 6. REMOVE ALL EXISTING EQUIPMENT, DUCTWORK AND PIPING THAT IS NOT REQUIRED FOR A WORKING INSTALLATION. 7. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION. 8. UNLESS OTHERWISE INDICATED, INSTALL ALL SPACE THERMOSTATS AND OTHER OCCUPANT ADJUSTABLE CONTROL DEVICES SAME HEIGHT AS ADJACENT LIGHT SWITCHES, BUT IN NO CASE HIGHER THAN 48 INCHES ABOVE FINISHED FLOOR PER ADA REQUIREMENTS. COORDINATE EXACT HEIGHT WITH ARCHITECT PRIOR TO INSTALLATION. 9. ALL CUTTING AND PATCHING SHALL BE CLOSELY COORDINATED WITH THE G.C. 10. COORDINATE ROUTING OF PLUMBING, AND HVAC PIPING WITH DUCTWORK, LIGHTS, ARCHITECTURAL CEILING AND STRUCTURAL ELEMENTS. PIPING SHALL RISE AND DROP, JOG OR OFFSET AS REQUIRED TO AVOID CONFLICTS. DUCTWORK SHALL TAKE PRECEDENCE OVER ALL PIPING, EXCEPT WHERE GRADE MUST BE MAINTAINED FOR DRAINAGE. REWORK OF INSTALLED WORK TO RESOLVE CONFLICTS RISING FROM LACK OF COORDINATION SHALL NOT JUSTIFY AN INCREASE IN THE CONTRACT AMOUNT. 11. ALL DIFFUSERS ARE 4-WAY BLOW UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 12. FLEXIBLE DUCTWORK IS ALLOWED ON RUNOUTS TO SUPPLY DIFFUSERS ONLY. UTILIZE ONLY ABOVE LAY-IN ACCESSIBLE CEILINGS. DO NOT INSTALL FLEX DUCT ABOVE HARD CEILINGS OR WHERE EXPOSED. A MAXIMUM LENGTH OF 6'-0" MAY BE USED AT EACH CONNECTION. 13. SEAL DUCTWORK AS CALLED OUT BELOW USING HARDCAST DT TAPE AND FTA-20 ADHESIVE OR HARDCAST AFG-1402 "FOIL GRIP" PER MANUFACTURERS INSTRUCTIONS. TYPE OF DUCT APPLY TO JOINTS EXHAUST DUCT (ROUND OR RECT)TRANSVERSE AND LONGITUDINAL MEDIUM VELOCITY (ROUND)TRANSVERSE AND LONGITUDINAL MEDIUM VELOCITY (RECTANGULAR)TRANSVERSE AND LONGITUDINAL LOW VELOCITY SUPPLY AND RETURN (RECT)TRANSVERSE AND LONGITUDINAL LOW VELOCITY SUPPLY (ROUND)TRANSVERSE AND LONGITUDINAL 14. INSTALL BALANCE DAMPER WITH STANDOFF AND LOCKING QUADRANT IN AN ACCESSIBLE LOCATION AT EACH RUNOUT TO SUPPLY DIFFUSERS, EXHAUST GRILLES, AND RETURN GRILLES WHERE AIRFLOW IS INDICATED, OR AS INDICATED OTHERWISE. 15. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE STOPPED BY THE TRADE MAKING THE PENETRATION. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR REQUIREMENTS. 16. DO NOT ROUTE PIPING OR DUCTWORK OVER ELECTRICAL PANELS OR EQUIPMENT. PIPING OR DUCTWORK SHALL NOT BE ROUTED THROUGH ELECTRICAL ROOMS, TELECOM ROOMS OR ELEVATOR EQUIPMENT ROOMS UNLESS SPECIFICALLY SERVING THAT ROOM. COORDINATE WITH E.C. PROVIDE WATERTIGHT DRIP PAN WITH DRAIN TO NEAREST APPROVED RECEPTOR WHERE REQUIRED. 17. COORDINATE SIZE AND LOCATION OF ACCESS DOORS IN CONSTRUCTION REQUIRED FOR ACCESS TO MECHANICAL EQUIPMENT WITH G.C. 18. COORDINATE SIZE AND LOCATION OF MECHANICAL EQUIPMENT PADS WITH G.C. 19. ALL WORK IS TO CONFORM WITH APPLICABLE CODES AND STANDARDS. 20. DUCT SIZES SHOWN ARE ACTUAL INSIDE CLEAR DIMENSIONS. INCREASE SHEET METAL DIMENSIONS AS REQUIRED TO ACCOMMODATE DUCT LINER WHERE LINER IS SPECIFIED. 21. ALL EQUIPMENT SUPPORT STANDS SHALL BE PRIMED AND PAINTED WITH EPOXY ENAMEL. 22. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING MOUNTED AIR DISTRIBUTION DEVICES. 23. PAINT INSIDE OF DUCTWORK BLACK ANYWHERE VISIBLE THROUGH FACE OF GRILLE OR DIFFUSER. 24. WHERE HYDRONIC RUNOUT SIZES ARE NOT INDICATED, SIZE PER THE FOLLOWING: UP TO 3 GPM -3/4"; UP TO 6 GPM -1"; UP TO 10 GPM -1-1/4"; UP TO 17 GPM -1-1/2". 25. HYDRONIC PIPING SHALL BE MAINTAINED FULL SIZE UP TO COIL CONNECTIONS. SHUT-OFF VALVES, STRAINERS, BALANCE VALVES, ETC. WILL NOT BE ALLOWED TO REDUCE FROM LINE/RUNOUT SIZE. CONTROL VALVES MAY BE DOWN SIZED FOR FLOW RATE, NOT TO EXCEED 4 PSIG PRESSURE DROP AT DESIGN FLOW. 26. TEMPERATURE CONTROLS CONTRACTOR (T.C.C.) SHALL FURNISH AND INSTALL ALL LOW VOLTAGE WIRING AND ASSOCIATED CONDUIT REQUIRED FOR MECHANICAL CONTROL SYSTEM. WIRING SHALL BE IN CONDUIT INSIDE WALLS, IN ROOMS WITH EXPOSED CEILINGS, AND ABOVE HARD CEILINGS. LINE VOLTAGE WIRING AND ASSOCIATED CONDUIT SHALL BE PROVIDED AND INSTALLED BY E.C. CONTROL SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATIONS. 27. ALL CONTROL DAMPERS SHALL BE FURNISHED BY T.C.C. AND INSTALLED BY THE M.C. MOTOR OPERATORS SHALL BE FURNISHED AND INSTALLED BY THE T.C.C. 28. COORDINATE ACCESS TO EQUIPMENT AND VALVES INSTALLED ABOVE 'HARD' CEILINGS AND IN MASONRY CHASES WITH GENERAL CONTRACTOR. PROVIDE LOCKING ACCESS DOORS FOR INSTALLATION BY CONTRACTOR AS REQUIRED TO SERVICE CONCEALED DAMPERS, VALVES AND EQUIPMENT. CEILING ACCESS DOORS FOR FIRE DAMPERS, SMOKE DAMPERS AND FIRE SMOKE DAMPERS FURNISHED AND INSTALLED BY CONTRACTOR. 29. CONTRACTOR TO INSTALL TEMPORARY FILTERS OVER ALL RETURN AND EXHAUST GRILLES IN WORK AREA DURING CONSTRUCTION. 30. THESE DRAWINGS ARE ACCOMPANIED BY SPECIFICATIONS. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION. 31. EQUIPMENT THAT REQUIRES MAINTENANCE SHALL BE LOCATED A MINIMUM OF 10'-0" FROM THE BUILDING ROOF EDGE WHERE REQUIRED BY CODE. 32. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF TEMPORARY PARTITIONS. 33. SQUARE THROAT NOT ALLOWED ON RADIUS ELBOWS. 34. HYDRONIC AND PLUMBING VALVES, CIRCUIT SETTERS AND OTHER ACCESSORIES REQUIRING ACCESS SHALL BE ACCESSIBLE VIA A STANDARD LADDER SO COMPONENTS MAY BE REPLACED, REPAIRED, OR UTILIZED WITHOUT THE NEED FOR EXTENSIVE CEILING REMOVAL, SCAFFOLDING OR A MAN LIFT.WHERE POSSIBLE NO MORE THAN 48”ABOVE THE FINISHED CEILING. 1. VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE ARCHITECT IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. REMOVAL OF EXISTING FIXTURES AND EQUIPMENT WILL REQUIRE ISOLATING THE PIPING RISERS OR MAINS VIA SHUT-OFF VALVES. INSTALL NEW ISOLATION VALVES WHERE REQUIRED FOR COMPLETION OF WORK. 3. REMOVAL OF EXISTING PLUMBING FIXTURES AND EQUIPMENT, ETC. WILL REQUIRE CAPPING AND SEALING EXISTING MAINS OR BRANCHES AS NECESSARY AND REQUIRED TO ALLOW THE REMAINING SYSTEMS TO FULLY OPERATE WITHOUT DEGRADATION. 4. CONTRACTOR SHALL PROVIDE PROTECTIVE PLASTIC DROP CLOTHS TO PROTECT THE EXISTING OCCUPIED AREAS AND EQUIPMENT FROM DUST AND DEBRIS DURING THE CONSTRUCTION WORK, AND SHALL CLEAN THE AREAS OF ALL CONSTRUCTION DIRT DAILY, AND UPON COMPLETION OF THE WORK. 5. ALL DRAINED PIPING RISERS AND MAINS SHALL BE REFILLED WITH PROPER FLUID AND PROPERLY VENTED BY THIS CONTRACTOR, ONCE NEW WORK HAS BEEN INSTALLED. 6. COORDINATE WITH GENERAL CONTRACTOR THE REMOVAL AND REPLACEMENT OF ALL EXISTING CEILINGS, WALLS, ETC. AS REQUIRED FOR MECHANICAL DEMOLITION WORK. 7. EXISTING PIPING AND EQUIPMENT, ETC., NOT TO BE UTILIZED IN THE COMPLETED BUILDING SHALL BE DISCONTINUED OR REMOVED AS REQUIRED. ALL ENDS OF DISCONTINUED PIPING SHALL BE CAPPED IN THE NEAREST WALL, CEILING OR FLOOR SO THAT THEY ARE COMPLETELY CONCEALED. OPENINGS LEFT IN WALLS, CEILINGS, ETC., WHERE EQUIPMENT AND PIPE, ETC., ARE REMOVED AND NOT REPLACED, SHALL BE PATCHED NEATLY WITH SIMILAR MATERIAL TO ADJACENT CONSTRUCTION. REFER TO DRAWINGS DELINEATING NEW WORK FOR ADDITIONAL INFORMATION REGARDING SYSTEMS OR PORTIONS OF SYSTEMS WHERE USE IS TO BE DISCONTINUED. 8. EXISTING PIPING, FIXTURES AND EQUIPMENT THAT ARE NOT TO BE REUSED SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE OWNER IF THEY WISH TO RETAIN OWNERSHIP OF SAME. IF NOT, EQUIPMENT SHALL BECOME THE PROPERTY OF THIS CONTRACTOR AND SHALL BE REMOVED FROM THE SITE AS SOON AS PRACTICAL AND DISPOSED OF IN ACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS. 9. ALL CUTTING AND CHANNELING OF EXISTING BUILDING SHALL BE ACCOMPLISHED IN A NEAT AND WORKMANLIKE MANNER WITHOUT REMOVAL OF EXCESS MATERIALS. THIS CONTRACTOR SHALL PATCH AND REPLACE WITH MATERIAL SIMILAR TO ADJACENT CONSTRUCTION. 10. WHERE EXISTING PIPING AND EQUIPMENT, ETC., THAT ARE TO BE UTILIZED IN THE COMPLETED PROGRAM CONFLICT WITH NEW CONSTRUCTION AND THE REQUIRED DEMOLITION, THEY SHALL BE RELOCATED AND RECONNECTED TO MAINTAIN THE DESIRED SERVICE. 11. PORTIONS OF EXISTING SYSTEMS MAY BE SHOWN FOR CLARITY EVEN THOUGH IT MAY NOT BE NECESSARY TO MODIFY OR REVISE THEM. ALL EXISTING SYSTEMS ARE SHOWN BASED ON ORIGINAL OR REMODEL BUILDING DRAWINGS. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS. 12. ALL WORK MUST BE COORDINATED AND SCHEDULED WITH THE OWNER AND OCCUPANTS OF THIS BUILDING SO AS TO PROVIDE THE LEAST AMOUNT OF DISRUPTION OF BUILDING ACTIVITIES AS POSSIBLE. MAINTAIN CONDITIONED SPACE FOR ALL OWNER OCCUPIED AREAS DURING CONSTRUCTION. 13. ALL ACCESSIBLE ABANDONED PIPING AND DUCTWORK SHALL BE REMOVED AND PROPERLY DISPOSED OF. NOTE: NOT ALL MAY APPLY TO PROJECT SHEET NUMBER WHERE REFERENCED SHEET NUMBER WHERE DRAWN DETAIL NUMBER SHEET NUMBER WHERE DRAWN DETAIL NUMBER SHEET NUMBER WHERE REFERENCED EQUIPMENT CALLOUT SHEET NUMBER WHERE DRAWN SECTION LETTER 111 1 REFER TO PLAN NOTES#ROOM CALLOUT DEMOLITION PEN WEIGHT -COMPONENT MAY ALSO BE SHADED CONNECT NEW TO EXISTING. VERIFY EXACT LOCATION. REVISION NUMBER EXISTING COMPONENT PEN WEIGHT EXISTING EQUIPMENT OR MATERIAL DESIGNATION(E) DISCONNECT FROM EXISTING. VERIFY EXACT LOCATION. E.C.ELECTRICAL CONTRACTOR GENERAL CONTRACTORG.C. P.C.PLUMBING CONTRACTOR M.C.MECHANICAL CONTRACTOR TEMPERATURE CONTROL CONTRACTORT.C.C. SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC & PLUMBING SYMBOL SCHEDULE GAS COCK / GLOBE VALVE GATE VALVE -SHUT OFF VALVE VALVE IN DROP / VALVE IN RISER BUTTERFLY VALVE 2-WAY / 3-WAY CONTROL VALVE (PNEUMATIC) BALL VALVE PLUG VALVE STRAINER / UNION OR FLANGE CONNECTION THERMOMETER / PRESSURE GAUGE CHECK VALVE3 PIECE BALL VALVE / HYDRAULIC VALVE EMERGENCY VALVE WITH FIRE LINK 2-WAY / 3-WAY CONTROL VALVE (ELECTRIC) PRESSURE REDUCING VALVE (PRV) / WAFER CHECK VALVE CIRCUIT SETTER -CALIBRATED BALANCE VALVE CALIBRATED ORIFICE PLATE FLOW METER AUTOMATIC FLOW CONTROL VALVE SPRING HANGER / PIPE HANGER DOUBLE CHECK BACKFLOW ASSEMBLY REDUCED PRESSURE ZONE BACKFLOW ASSEMBLY CAP / CAPPED OUTLET PIPE DROP / PIPE RISE TOP CONNECTION, 45° OR 90° / BOTTOM CONNECTION, 45° OR 90° SIDE CONNECTIONDIRECTION OF FLOW / ANCHOR CONCENTRIC REDUCER OR INCREASER / ECCENTRIC REDUCER DOMESTIC COLD WATER LINE (CW)ABOVE FLOOR WASTE LINE (W) BELOW WASTE LINE (W)DOMESTIC HOT WATER LINE (HW) HOT WATER RECIRC LINE (HWC)PLUMBING VENT LINE (V) F RL RAIN LEADER (RL) / OVERFLOW RAIN LEADER (ORL) FIRE PROTECTION LINE (F)SWS STORM SEWER (SWS) CD COOLING COIL CONDENSATE DRAIN LINE (CD) WCO CO CO CO FLOOR DRAIN / TRENCH DRAIN PLUMBING FIXTURE CALLOUT WATER HAMMER ARRESTOR -PDI SIZE P-# WHA# DOMESTIC HOT WATER PUMPDHWP VTR VENT THROUGH ROOF WALL CLEANOUT / END OF LINE CLEANOUT CLEANOUT (FLOOR) / 2-WAY CLEANOUT (FLOOR) HOSE REEL / HOSE BIBB G NATURAL GAS LINE (G) BOTTOM OF PIPE ELEVATION ABOVE FLOORBOP TOP TOP OF PIPE ELEVATION ABOVE FLOOR ROOF DRAIN / OVERFLOW ROOF DRAIN VITRIFIED CLAY PIPE / POLYVINYL CHLORIDE PIPE CI CAST IRON F/S WH-# FILTER-SEPARATOR WATER HEATER CALLOUT WALL HYDRANTWH FS FLOOR SINK TYP.TYPICAL ALL INSTANCES NOT ALL MAY BE USED ON PROJECT THERMOSTATIC MIXING VALVETMV SR SUPPLY REGISTER MAKE-UP AIR UNITMAU HUMIDIFIERH DP DIFFERENTIAL PRESSURE UH UNIT HEATER COMPUTER ROOM AIR CONDITIONING UNITCRAC ULTRAVIOLET STERILE CONDITIONERUV 24x12 24x12 24x12 RETURN DUCT RISER SUPPLY DUCT DROP / RETURN DUCT DROP SUPPLY DUCT RISER FLEXIBLE DUCT TURNING VANES (UP)DUCT SEC., POSITIVE PRESSURE-FIRST SIZE IS TOP DIM.(TYP.) (DOWN) DUCT SECTION, POSITIVE PRESSURE (UP) DUCT SECTION, NEGATIVE PRESSURE R 24x12 18x12 BALANCING DAMPER W/ MANUAL LOCKING QUADRANT SIDE WALL SUPPLY REGISTER (DOWN) DUCT SECTION, NEGATIVE PRESSURE DUCT SIZE, FIRST FIGURE IS SIDE SHOWN-CLEAR INSIDE DIM. DUCT CHANGE OF ELEVATION RISE(R) DROP(D) FLEXIBLE CONNECTION BALANCING DAMPER W/ MOTORIZED LOCKING QUADRANT TH ELECTRIC OR DDC THERMOSTAT (TSTAT) FIRE DAMPER IN WALLFD SD SMOKE DAMPER FD FIRE DAMPER IN FLOOR ELECTRIC OR DDC HUMIDISTAT (HSTAT) T M H TEMPERATURE SENSOR MOTOR HUMIDITY SENSOR R RADIATION DAMPER COMBINATION FIRE/SMOKE DAMPER IN WALLFSD FSD COMBINATION FIRE/SMOKE DAMPER IN FLOOR OPPOSED BLADE DAMPEROBD TOP OF DUCT ELEVATION ABOVE FLOOR BOD TOD FTU / FCU SF SUPPLY AIR FAN FAN POWERED TERMINAL UNIT / FAN COIL UNIT ROOFTOP UNIT / AIR HANDLING UNITRTU / AHU F FURNACE SA / OA SUPPLY AIR / OUTSIDE AIR RETURN AIR / EXHAUST AIRRA / EA DH DUCT HEATER BOTTOM OF DUCT ELEVATION ABOVE FLOOR BOS BOTTOM OF STEEL EF / RG EXHAUST FAN / RETURN GRILLE VAV VARIABLE AIR VOLUME UNIT CVR CONSTANT VOLUME REHEAT UNIT V V R VARIABLE VOLUME REHEAT UNIT VARIABLE VOLUME VARIABLE TEMPERATUREV V T RECTANGULAR -OPPOSED BLADE / ROUND -BUTTERFLY RECTANGULAR -OPPOSED BLADE / ROUND -BUTTERFLY VARIABLE FREQUENCY DRIVEVFD CWS CHILLED WATER SUPPLY LINE (CWS) CWR CHILLED WATER RETURN LINE (CWR)CWP CHILLED WATER PUMP CWPP / CWSP CHILLED WATER PRIMARY PUMP / SECONDARY PUMP ORL FD / TD RD / ORD VCP / PVC HR / HB UNFILTERED DOMESTIC COLD WATER LINE (UCW)PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:06 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 MP001MECHANICAL COVER SHEET Atlantic BeachFleet LandingColeman RemodelFloridaJDB SHEET LIST MP001 MECHANICAL COVER SHEET M101 1/8" FIRST FLOOR DEMO PLAN - HVAC M102 1/8" SECOND FLOOR DEMO PLAN - HVAC M103 1/8" ROOF DEMO PLAN - HVAC M201 1/8" FIRST FLOOR PLAN - HVAC M202 1/8" SECOND FLOOR PLAN - HVAC M203 1/8" FIRST FLOOR PLAN - HYDRONICS M204 1/8" SECOND FLOOR PLAN - HYDRONICS M205 1/8" ROOF PLAN - HVAC M300 1/2" ENLARGED CHILLER PLAN MT100 HVAC SCHEDULES MT102 HVAC SCHEDULES MT103 HVAC SCHEDULES MT200 HVAC DETAILS MT201 HVAC DETAILS MT300 HVAC CONTROLS MT301 HVAC CONTROLS P101 1/8" FIRST FLOOR DEMO PLAN - PLUMBING P102 1/8" SECOND FLOOR DEMO PLAN - PLUMBING P200 1/8" FIRST FLOOR PLAN - UNDERGROUND PLUMBING P201 1/8" FIRST FLOOR PLAN - PLUMBING P202 1/8" SECOND FLOOR PLAN - PLUMBING P300 1/4" ENALRGED PLANS - PLUMBING P400 PLUMBING RISER DIAGRAMS P401 PLUMBING RISER DIAGRAMS PT100 PLUMBING SCHEDULES AND DETAILS NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6G DEMO (E) CHILLED WATER AIR HANDLERS, AHU-1 THRU 6, AND ALL ASSOCIATED DUCTWORK, CWS/R PIPING, FAN COILS AND RELATIVE APPURTENANCES. (E) EXAHUST SYSTEM FOR RESTROOM GROUP TO REMAIN. (E) ELEVATORS AND ASSOCIATED EQUIPMENT NOT IN SCOPE. (E) VESTIBULE HAS JUST FINISHED A RENOVATION. HVAC FOR VESTIBULE SHALL BE TIED INTO NEW SYSTEMS. HVAC DEMO NOTES 1. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. DEMOLISH ALL DUCTWORK, PIPING, AND EQUIPMENT SHOWN SHADED, DASHED AND IN A DARK LINE WEIGHT. PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:41:55 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 M1011/8" FIRST FLOOR DEMO PLAN - HVAC Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6 G (E) AIR HANDLERS, AHU-7 AND AHU-8, IN MEZZANINE ARE TO BE REMOVED AND REPLACED.(E) AIR HANDLER, AHU-9 IN MEZZANINE ARE TO BE REMOVED AND REPLACED. (E) OUTSIDE AIR DUCT AND ASSOCIATED HOOD FOR AHU-9 TO BE REMOVED AND REPLACED WITH NEW. (E) EXHAUST DUCT AND ASSOCIATED FAN TO REMAIN. (E) 22x22 OUTSIDE AIR DUCT AND ASSOCIATED HOOD SERVING (E) AHU-7 AND (E)AHU-8 TO BE REMOVED AND REPLACED. DEMO (E) SUPPLY AND RETURN DUCT AS SHOWN. CONTRACTOR SHALL FIELD VERIFY EXACT LAYOUTS. (E) KITCHEN HOOD AND ALL ASSOCIATED DUCTWORK, PIPING AND APPURTENANCES TO BE REMOVED. ALL (E) SLOT DIFFUSERS IN ATRIUM TO BE REMOVED. (E) KITCHEN NOT IN SCOPE (E) GRILLES TO BE REMOVED AND REPLACED WITH NEW. (E) GRILLES TO BE REMOVED. (E) GRILLES TO BE REMOVED AND REPLACED WITH NEW. 24x2438x24 30x30 42x24 8x248x16 24x16 HVAC DEMO NOTES 1. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. DEMOLISH ALL DUCTWORK, PIPING, AND EQUIPMENT SHOWN SHADED, DASHED AND IN A DARK LINE WEIGHT. PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:42:02 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 M1021/8" SECOND FLOOR DEMO PLAN - HVAC Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6 G (E) INTAKE HOOD TO BE REMOVED AND REPLACED. (E) EXHAUST FAN AND MAKEUP AIR UNIT FOR (E) KITCHEN HOOD TO BE REMOVED. CONTRACTOR SHALL PATCH ROOF AS NECESSARY AND MATCH (E) ROOFING. (E) RESTROOM EF. (E) INTAKE HOOD TO BE REMOVED AND REPLACED. HVAC DEMO NOTES 1. PLANS ARE SCHEMATIC IN NATURE. LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. DEMOLISH ALL DUCTWORK, PIPING, AND EQUIPMENT SHOWN SHADED, DASHED AND IN A DARK LINE WEIGHT. PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:42:11 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 M1031/8" ROOF DEMO PLAN - HVAC Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION T T T TT T T T T TT T T T T T T T T T T T T T T T T T T T T A B C D E F 1 2 3 4 5 6 G CONFERENCE ROOM 118 OFFICE 114 EXISTING WATER SUPPLY 110 EXISTING ELECT 107 ? ? ELEVATOR EQUIPMENT 104 SOCIAL MAIL 102 WORK ROOM 129 CONFERENCE ROOM 131 EXECUTIVE GATHERING 128 OFFICE 124 OFFICE 125 OFFICE 126 OFFICE 127 OFFICE 133 MECH 132 SALES & FINISHES 135 STAIR 1 001 STAIR 2 002 MARKETING 143 LIBRARY DIRECTOR 142 MECH 139 MKTG DIR 146 SPORTS BAR 155 RECEPTION 122 VEST 123 ELEVATOR LOBBY 121 CORRIDOR 101 IT 138 STORAGE 130 ATRIUM 136 CORRIDOR 137 REAR VEST 134 SALES & MARKETING 140 OFFICE 141 IL SALES 145 AL SALES 147 OFFICE 149 OFFICE 150 SUPPLY 148EXISTING LIBRARY 151 MEN 164 SHOWER 163 TOILET 162 WOMEN 161 EXT'G MECH 109 MECH/ELEC 159 A/C CLOSET 158CORR 160 ELEV 1 E001 ELEV 2 E002 ELEV 3 E003 EXISTNG VESTIBULE 119 IT 156 BAR SERVICE 154 DEVELOPMENT DIRECTOR 103 PANTRY 157 STORAGE 113 MECH 152 OFFICE 116 FOOD SERVICE DIRECTOR 117 CORRIDOR 115 JANITOR 112 EXISTING CORRIDOR 111 SJ6145 SJ8200 SJ10250 SJ10250SJ6165SJ6150 AHU-1 AHU-2 AHU-4 AHU-5 AHU-3 PROVIDE NEW CHILLED WATER VAV AIR HANDLER TO SERVE FIRST FLOOR. TYPICAL 5 SJ650 SJ6135 SJ6100 LSE8-1s100 LSE8-1s100 LSE8-1s100 LSE8-1s155 LSE10-2s210 LSE10-2s210 LSE8-1s125 LSE8-1s125 SJ650 SJ6100 SJ650 SJ650 SJ650 SJ8250 SJ10320 SJ8175 SJ8175 SJ8175 SJ8250 LSE10-2s250 LSE8-2s125 LSE8-2s125 SJ6200 LSE8-1s175 LSE8-1s150 LSE8-1s150 LSE8-2s200 SJ680 SJ6170 SJ665 SJ675 SJ675 LSE8-1s150 LSE8-1s150 LSE8-1s150 LSE8-1s150 LSE8-2s200 LSE8-2s200 LSE8-2s200 TERMINATE AHU OA INTAKE AND RELIEF WITH LOUVER IN EXTERIOR WALKWAY CEILING. TYPICAL TERMINATE AHU OA INTAKE LOUVER IN EXTERIOR WALKWAY CEILING. VAV.4.1 VAV.4.2 VAV.4.3 VAV.4.4 VAV.4.5 VAV.4.6 VAV.4.7 VAV.3.1 VAV.3.2 VAV.2.2 VAV.2.1 VAV.2.3 VAV.1.1 VAV.1.2 VAV.1.3 VAV.1.4 VAV.1.5 VAV.1.6 VAV.5.1 VAV.5.2 VAV.5.3 VAV.5.4 VAV.5.5 VAV.5.6 VAV.5.7 VAV.5.8 VAV.5.9 VAV.5.10 VAV.5.11 VAV.5.12 LSE8-1s150LSE8-1s150 LSE10-2s250 (TYP. 4) LSE8-2s200 12x12 12x10 12x10 20x1620x16 20x16 12x10 LRE12-4s400 (TYP. 3) (TYP. 3) 12x12 10x8 14x13 12x10 20x1220x20 26x1626x16 20x20 34x1212x12 12x8 16x12TYPICAL RF DIFFUSER.18x1224x20 24x20 14x10 14x10 12x10 32x1212x1220x88x8 18x10 14x14 14x1412x8LRE10-3s300 (TYP. 3) 12x8 14x10 12x8 10x1024x1214x1010x8 12x812x1012x8SB6100 SA650 SB6125 (E) RESTROOM EXHAUST FANS TO BE REUSED.14x1214x12 LRD8-3s600 SJ650 SX6x650 SJ675 SJ675 EXISTING HVAC EQUIPMENT SERVING ELEVATOR ROOM TO REMAIN. L-1 L-2 L-3 EXISTING MINI-SPLIT SREVING IT ROOM TO REMAIN.16x12SX12x12200 VAV.1.7 L-4 L-5 L-6 L-7 L-8 (TYP. 4) 8"ø 12x8AC.1 14x1214"øSJ10280 PROVIDE INSULATED BACKING FOR T-STAT ON EXTERIOR WALL. LRE10-2s250 (TYP. 2) LSE6-1s85 LSE6-1s90 MECHANICAL GENERAL NOTES 1. DUCT SIZES SHOWN ARE ACTUAL INSIDE CLEAR DIMENSIONS. INSULATION THICKNESS HAS NOT BEEN ACCOUNTED FOR. DUCTWORK EXPOSED TO SPACE SHALL NOT HAVE EXTERIOR INSULATION. 2. T-STATS AND OTHER CONTROL DEVICES SHALL BE LOCATED NEXT TO LIGHT SWITCH WITHIN THE ROOM SHOWN. COORDINATE WITH GC AND ELECTRICAL CONTRACTOR TO MATCH HEIGHT AND LOCATION. 3. AVOID ROUTING DUCTWORK OVER ELECTRICAL ROOMS AND ELECTRICAL PANELS. MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR. 4. ALL SUPPLY AIR BRANCHES FOR SUPPLY DIFFUSERS TO HAVE MANUAL BALANCE DAMPERS, NOT ALL SHOWN FOR CLARITY. WHERE HARDLID CEILINGS PREVENT BALANCE DAMPER ACCESS, CONFIRM WITH GRD SCHEDULE OR ENGINEER TO USE OBD’S OR REMOTE BALANCE DAMPERS. 5. ALL DUCTWORK SHALL BE ROUTED AS HIGH AS POSSIBLE WITHIN THE CEILING SPACE. UTILIZE JOIST SPACE WHERE POSSIBLE, ESPECIALLY WHEN CROSSING OTHER DUCT, PIPE AND ELECTRICAL. 6. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO ALL MOTORIZED EQUIPMENT. 7. VERIFY ALL EQUIPMENT ACCESS PANELS WITH MANUFACTURER AND ARCHITECT. ACCESS PANELS SHALL BE 24X24 U.N.O. LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECT AND THE LOCATIONS OF THE EQUIPMENT THEY SERVE. ACCESS PANELS SHALL NOT BE INSTALLED IN WOOD CEILINGS. 8. COORDINATE FINISH OF ALL EXPOSED DUCT WITH ARCHITECT. DUCTWORK THAT IS TO BE PAINTED SHALL HAVE A PAINT GRIP FINISH ACCEPTABLE FOR PAINTING. 9. EXPOSED SPIRAL DUCT GRILLES SHALL BE INSTALLED AT A 30 DEGREE ANGLE DOWNWARD BELOW HORIZONTAL. 10. REFER TO GRD SCHEDULE FOR DUCT CONNECTION SIZES. REFER TO TERMINAL BOX SCHEDULE FOR INLET DUCT SIZES. 11. CEILING COORDINATION OF ALL MEP SYSTEMS (LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL, ETC.) MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO THE START OF ANY NEW INSTALLATION.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:42:30 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 M2011/8" FIRST FLOOR PLAN - HVAC Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION K T T T T T T A B C D E F 1 2 3 4 5 6 G STAIR 1 001 STAIR 2 002 MENS ACCESSIBLE 208 RESTROOM 211 COATS 212 BEV STATION 209 EXISTING WOMENS 206 EXISTING MENS 207 WOMENS ACCESSIBLE 205 OFFICE 204 EXHIBITION DINING 223 EXHIBITION KITCHEN 222 KITCHEN SUPPORT 221 GALLERY 220 ELEV LOBBY 213 COMMUNITY DINING 210 BEV STATION 218 PRIVATE DINING/WINE ROOM 219 EXT'G ELEC 217 BEV SUPPLIES 225 BAR/BEV STATION 224 EXISTING MECH 226 EXISTING KITCHEN 201 ELEV 1 E001 ELEV 2 E002 ELEV 3 E003 EXISTING WALK-IN 202 PANTRY 203 J.C. 15 AHU-6 AHU-8 AHU-728x28 OA DUCT DOWN FROM NEW INTAKE HOOD ON ROOD. BRANCH DUCT IN MEZZANINE AND ROUTE 30x20 OA TO AHU-6 AND 20x16 TO AHU-8. 20x18 20x18 14x1214x12 SX22x6400(TYP. 10)40x24UP TO EXISTING EXHAUST FAN, REBALANCE TO 940 CFM UP TO NEW EXHAUST FAN, EF-1. UP TO NEW MAU ON ROOF, MAU-1. (E) KITCHEN NOT IN SCOPE VAV.7.1 VAV.7.3 VAV.7.4 VAV.7.5 VAV.7.222x2022x20 E ( )42x24 E ( )30x30 UP TO IH-1 AND RH-1ON ROOF. 34x24 28x2028x2012"ø 14"ø 16x15 E ( )24x16 30x20 22x1414x13 16x14 12x10 16x12 SC650 SJ650 SJ675 SA650 EC6x675 EC675 8x8 10"ø LSE8-1s150 LSE8-1s150 LSE10-2s250(TYP. 6) LSE6-1s75 (TYP. 10) RG12x12440 SJ10440 LSE10-2s250(TYP. 2) E ( )8x24 E ( )8x16 E ( )24x24 E ( )38x24 SJ690 SJ8160 TIE (E) DUCTWORK INTO NEW AHU. FIELD VERIFY EXISTING CONNECTIONS. E ( )16x12 VERIFY FINAL CONNECTIONS TO HOOD WITH KITCHEN CONSULTANT DRAWINGS. REFER TO HOOD DRAWINGS FOR AIRFLOW BALANCING. SX18x10700 1 SJ8160 TIE (E) DUCTWORK INTO NEW AHU. FIELD VERIFY EXISTING CONNECTIONS. SX12x10350(TYP. 2) 3 3 3 3 26x2626x26 RX42x365510 E ( )30x30 LRE10-2s250 (TYP. 2) 16x10 ALL EXTERIOR LINEAR SLOT DIFFUSERS TO HAVE TOP CONNECTIONS TO FIT IN SOFFIT. CONTRACTOR TO PROVIDE CUSTOM CONNECTION AS NEEDED. 2 KITCHEN EXHAUST DUCT LRE12-4s375 (E)350 (E)200(E)70 (E)125 (E)400(E)375(E)90 E ( )14x14DUCTWORK WITHIN CUSTOM METAL SOFFIT. DUCTWORK TO BE INSTALLED AT TOP OF SOFFIT THROUGHOUT TO MAINTAIN ELEVATION FOR GRILLE CONNECTIONS. DUCTWORK SHALL BE LINED IN THE SOFFIT; SIZES CALLED OUT ARE EXTERIOR SHEET METAL, LINING HAS BEEN ACCOUNTED FOR. COORDINATE WITH ARCHITECTURAL DRAWINGS. LRE12-4s700(TYP. 3) 26x1612x1212x1236x36 RETURN DUCT TO RELIEF HOOD, RH-2. MECHANICAL GENERAL NOTES 1. DUCT SIZES SHOWN ARE ACTUAL INSIDE CLEAR DIMENSIONS. INSULATION THICKNESS HAS NOT BEEN ACCOUNTED FOR. DUCTWORK EXPOSED TO SPACE SHALL NOT HAVE EXTERIOR INSULATION. 2. T-STATS AND OTHER CONTROL DEVICES SHALL BE LOCATED NEXT TO LIGHT SWITCH WITHIN THE ROOM SHOWN. COORDINATE WITH GC AND ELECTRICAL CONTRACTOR TO MATCH HEIGHT AND LOCATION. 3. AVOID ROUTING DUCTWORK OVER ELECTRICAL ROOMS AND ELECTRICAL PANELS. MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR. 4. ALL SUPPLY AIR BRANCHES FOR SUPPLY DIFFUSERS TO HAVE MANUAL BALANCE DAMPERS, NOT ALL SHOWN FOR CLARITY. WHERE HARDLID CEILINGS PREVENT BALANCE DAMPER ACCESS, CONFIRM WITH GRD SCHEDULE OR ENGINEER TO USE OBD’S OR REMOTE BALANCE DAMPERS. 5. ALL DUCTWORK SHALL BE ROUTED AS HIGH AS POSSIBLE WITHIN THE CEILING SPACE. UTILIZE JOIST SPACE WHERE POSSIBLE, ESPECIALLY WHEN CROSSING OTHER DUCT, PIPE AND ELECTRICAL. 6. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO ALL MOTORIZED EQUIPMENT. 7. VERIFY ALL EQUIPMENT ACCESS PANELS WITH MANUFACTURER AND ARCHITECT. ACCESS PANELS SHALL BE 24X24 U.N.O. LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECT AND THE LOCATIONS OF THE EQUIPMENT THEY SERVE. ACCESS PANELS SHALL NOT BE INSTALLED IN WOOD CEILINGS. 8. COORDINATE FINISH OF ALL EXPOSED DUCT WITH ARCHITECT. DUCTWORK THAT IS TO BE PAINTED SHALL HAVE A PAINT GRIP FINISH ACCEPTABLE FOR PAINTING. 9. EXPOSED SPIRAL DUCT GRILLES SHALL BE INSTALLED AT A 30 DEGREE ANGLE DOWNWARD BELOW HORIZONTAL. 10. REFER TO GRD SCHEDULE FOR DUCT CONNECTION SIZES. REFER TO TERMINAL BOX SCHEDULE FOR INLET DUCT SIZES. 11. CEILING COORDINATION OF ALL MEP SYSTEMS (LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL, ETC.) MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO THE START OF ANY NEW INSTALLATION. 1. CONNECT NEW 8"ø DUCT TO (E)24x24 SUPPLY MAIN AND ROUTE TO DIFFUSER IN KITCHEN SUPPORT 221. 2. CONNECT NEW 10"ø DUCT TO (E)42x24 SUPPLY MAIN AND ROUTE TO DIFFUSERS SERVING BAR/BEV STATION 224 AND BEV SUPPLIES 225. 3. (E) DUCTWORK TO BE EXTENDED INTO (E) SOFFIT IN ATRIUM. DUCTWORK TO BE TERMINATED WITH A SUPPLY GRILLE THAT THROWS AIR VERTICALLY ALONG WINDOWS. TOTAL AIR FLOW SHALL BE 1,200 CFM. FIELD VERIFY EXISTING SOFFIT DIMENSIONS TO DETERMINE GRILLE SIZE. PLAN NOTES PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:42:44 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 M2021/8" SECOND FLOOR PLAN - HVAC Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6 G AHU-1 AHU-2 AHU-3 AHU-4 AHU-5 CONFERENCE ROOM 118 OFFICE 114 EXISTING WATER SUPPLY 110 EXISTING ELECT 107 ? ? ELEVATOR EQUIPMENT 104 SOCIAL MAIL 102 WORK ROOM 129 CONFERENCE ROOM 131 EXECUTIVE GATHERING 128 OFFICE 124 OFFICE 125 OFFICE 126 OFFICE 127 OFFICE 133 MECH 132 SALES & FINISHES 135STAIR 1 001 STAIR 2 002 MARKETING 143LIBRARY DIRECTOR 142 MECH 139 MKTG DIR 146 ? ? SPORTS BAR 155 RECEPTION 122 VEST 123 ELEVATOR LOBBY 121 CORRIDOR 101 IT 138 STORAGE 130 ATRIUM 136 CORRIDOR 137 REAR VEST 134 SALES & MARKETING 140 OFFICE 141 IL SALES 145 AL SALES 147 OFFICE 149 OFFICE 150 SUPPLY 148EXISTING LIBRARY 151 MEN 164 SHOWER 163 TOILET 162 WOMEN 161 EXT'G MECH 109 MECH/ELEC 159 A/C CLOSET 158 CORR 160 ELEV 1 E001 ELEV 2 E002 ELEV 3 E003 EXISTNG VESTIBULE 119 IT 156 BAR SERVICE 154 DEVELOPMENT DIRECTOR 103 PANTRY 157 STORAGE 113 MECH 152 OFFICE 116 FOOD SERVICE DIRECTOR 117 CORRIDOR 115 JANITOR 112 EXISTING CORRIDOR 111 ( ) E 6"CWR ( ) E 6"CWS (E)6" CWS/R PIPES UP TO SECOND FLOOR. 1-1/2" CWS/R PIPES TO AHU-2. 1-1/2''CWR 1-1/2''CWS 1-1/4" CWS/R PIPES TO AHU-1. 2-1/2''CWS 2-1/2''CWR 1-1/2" CWS/R PIPES TO AHU-3. 2"CWS 2"CWR 2"CWR 2"CWS 2"CWS 2"CWR 2" CWS/R PIPES TO AHU-5. 1-1/2''CWR 1-1/2''CWS1-1/2" CWS/R PIPES TO AHU-4. 2"CWS 2"CWR HYDRONICS GENERAL NOTES 1. PIPING ON EXTERIOR WALLS OR PRE-CAST CONCRETE WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION. 2. AVOID ROUTING PIPING OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR. 3. PROVIDE FLEXIBLE PIPE CONNECTIONS TO ALL MOTORIZED EQUIPMENT. 4. VERIFY ALL EQUIPMENT ACCESS PANELS WITH MANUFACTURER AND ARCHITECT. 5. REFER TO TERMINAL BOX SCHEDULE FOR ALL BRANCH HEATING WATER PIPE SIZES. 6. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN AN ACCESSIBLE LOCATIONS, OR WITH ACCESS PANELS IN HARDLID CEILINGS. ACCESS PANELS SHALL BE 24X24 U.N.O. COORDINATE PANEL LOCATIONS WITH ARCHITECT.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:42:50 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 M2031/8" FIRST FLOOR PLAN - HYDRONICS Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6 G STAIR 1 001 STAIR 2 002 ? ? MENS ACCESSIBLE 208 RESTROOM 211 COATS 212 BEV STATION 209 EXISTING WOMENS 206 EXISTING MENS 207 ? ?OFFICE 204 EXHIBITION DINING 223 EXHIBITION KITCHEN 222 KITCHEN SUPPORT 221 GALLERY 220 ELEV LOBBY 213 COMMUNITY DINING 210 BEV STATION 218 PRIVATE DINING/WINE ROOM 219 EXT'G ELEC 217 BEV SUPPLIES 225 BAR/BEV STATION 224 EXISTING MECH 226 EXISTING KITCHEN 201 ELEV 1 E001 ELEV 2 E002 ELEV 3 E003 EXISTING WALK-IN 202 PANTRY 203 ROOF ACCESS 219A DINING 227 AHU-6 AHU-8 AHU-7 6"CWR 6"CWS ( ) E 6"CWS ( ) E 6"CWR ROUTE NEW 2" CWS/R LINES TO AHU-7 IN MEZZANINE. 2-1/2" CWS/R LINES TO AHU-6 IN MEZZANINE. 3" CWS/R LINES TO AHU-8 IN MEZZANINE. 4"CWS 4"CWR 6" CWS/R PIPIES FROM FIRST FLOOR. HYDRONICS GENERAL NOTES 1. PIPING ON EXTERIOR WALLS OR PRE-CAST CONCRETE WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION. 2. AVOID ROUTING PIPING OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR. 3. PROVIDE FLEXIBLE PIPE CONNECTIONS TO ALL MOTORIZED EQUIPMENT. 4. VERIFY ALL EQUIPMENT ACCESS PANELS WITH MANUFACTURER AND ARCHITECT. 5. REFER TO TERMINAL BOX SCHEDULE FOR ALL BRANCH HEATING WATER PIPE SIZES. 6. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN AN ACCESSIBLE LOCATIONS, OR WITH ACCESS PANELS IN HARDLID CEILINGS. ACCESS PANELS SHALL BE 24X24 U.N.O. COORDINATE PANEL LOCATIONS WITH ARCHITECT.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:42:54 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 M2041/8" SECOND FLOOR PLAN - HYDRONICS Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6 G (E) RESTROOM EF KITCHEN HOOD EXHUAST FAN, EF-1. NEW MAU FOR KITCHEN HOOD, MAU-1. NEW AHU OA INTAKE, IH-2. NEW OA INTAKE FOR AHU, IH-1. NEW RELIEF HOOD FOR AHU, RH-1. NEW RELIEF HOOD FOR AHU, RH-2.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:42:58 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 M2051/8" ROOF PLAN - HVAC Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION (E) CHILLER TO REMAIN. (E) CHILLED WATER PUMP, EXPANSION TANK AND AIR SEPARATOR TO BE REMOVED AND REPLACED. (E) EQUIPMENT PAD (E) CHILLER VERTICAL DUAL-ARM INLINE PUMP, P-1. EXPANSION TANK, ET-1 AIR SEPARATOR, AS-1 8"CWS 8"CWR (E)CWS LINE TO BUILDING. (E) CONCRETE EQUIPMENT PADS. (E)CWR LINE TO BUILDING. REFER TO DETAIL 7/MT201 FOR AIR SEPARATOR AND EXPANSION TANK PIPING.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:04 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 M3001/2" ENLARGED CHILLER PLAN Atlantic BeachFleet LandingColeman RemodelFloridaJDB 0'8'12'4'1/2" = 1'-0" HVAC DEMOLITION PLAN - CHILLER10'8'12'4'1/2" = 1'-0" HVAC PLAN - CHILLER2 NO. DATE DESCRIPTION PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:10 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 MT100HVAC SCHEDULES Atlantic BeachFleet LandingColeman RemodelFloridaJDB S R P E L M C U = = = = = = = = SUPPLY DIFFUSER RETURN GRILLE PLENUM RETURN GRILLE EXHAUST GRILLE SLOT DIFFUSER LAMINAR FLOW SUPPLY DIFFUSER SECURITY GRILLE FLOOR MOUNTED SUPPLY GRILLE 1. 2. 3. 4. 5. 6. 7. 8. SECOND LETTER DENOTES SEQUENCE. NOT ALL MAY BE USED. PROVIDE SQUARE TO ROUND ADAPTERS AS REQUIRED TO ACCOMODATE ROUND RUNOUTS. PROVIDE ALL LAY-IN GRDs WITH 24x24 LAY-IN PANEL AS REQUIRED. FINISH TO BE WHITE UNLESS OTHERWISE SPECIFIED. COORDINATE AND VERIFY ALL FINISHES WITH ARCHITECT. ALL SELECTIONS ARE BASED ON A MAXIMUM NC OF 25 UNLESS NOTED OTHERWISE. CONTRACTOR SHALL VERIFY ALL CEILING TYPES AND ASSOCIATED BORDER TYPES. LOUVERED GRILLES TO HAVE FRONT BLADES PARALLEL TO LONG DIMENSION UNLESS WALL MOUNTED. WALL MOUNTED LOUVERED GRILLES TO HAVE FRONT BLADES PARALLEL TO FLOOR. FIRST LETTER IN MARK:NOTES: GRILLE, REGISTER, AND DIFFUSER SCHEDULE MARK TYPE IMAGE BASED ON MOUNT PANEL SIZE (FACE SIZE)MATERIAL BLADE SPACING / SLOT WIDTH DEFLECTION REMARKSMFR MODEL SA SUPPLY DIFFUSER TITUS TDC-AA LAY-IN 24x24 (6x6)ALUMINUM -- -- LOUVERED FACE SB SUPPLY DIFFUSER TITUS TDC-AA LAY-IN 24x24 (9x9)ALUMINUM -- -- LOUVERED FACE SC SUPPLY DIFFUSER TITUS TDC-AA LAY-IN 24x24 (12x12)ALUMINUM -- -- LOUVERED FACE SJ SUPPLY DIFFUSER TITUS OMNI-AA LAY-IN 24x24 ALUMINUM -- -- -- LSE SLOT DIFFUSER TITUS TBDI-80 LAY-IN 48" WIDTH ALUMINUM 1" -- SEE PLANS FOR SLOT QTY SX DUCT MOUNTED SUPPLY TITUS 300FS DUCT SEE PLANS ALUMINUM 3/4" DOUBLE -- RF RETURN GRILLE TITUS PAR LAY-IN 24x12 (22x10)ALUMINUM -- -- -- RG RETURN GRILLE TITUS PAR LAY-IN 24x24 (22x22)ALUMINUM -- -- -- LRD SLOT DIFFUSER TITUS TBR-80 LAY-IN 48" WIDTH ALUMINUM 3/4" -- SEE PLANS FOR SLOT QTY LRE SLOT DIFFUSER TITUS TBR-80 LAY-IN 48" WIDTH ALUMINUM 1" -- SEE PLANS FOR SLOT QTY RX DUCT MOUNTED RETURN TITUS 350FL/S DUCT SEE PLANS ALUMINUM 3/4" 35° -- EC EXHAUST GRILLE TITUS 350FL SURFACE 12x12 (10x10)ALUMINUM 3/4" 35° -- 1. 2. ALL EXHAUST FANS SHALL HAVE PERMANENTLY LUBRICATED BEARINGS AND DISCONNECT SWITCH PROVIDED AND INSTALLED BY EC. DOWNBLAST AND UPBLAST EXHAUST FANS SHALL BE PROVIDED WITH ECM MOTOR, FAN SPEED CONTROLLER, BACKDRAFT DAMPER, BIRDSCREEN, INTERNAL WIRING PIGTAIL AND ROOF CURB. VFD PROVIDED BY EQUIPMENT MANUFACTURER WHERE APPLICABLE. REMARKS: EXHAUST FAN SCHEDULE MARK LOC AT ROOM TYPE MIN CAP FAN RPM DRIVE MOTOR (BY M.C.)WT LBS MANUFACTURER AND MODELCFM SP HP ELEC START EF-1 ROOF UPBLAST 7,700 0.55 792 DIRECT 5 460/3 VFD - CAPTIVEAIRE DU300HFA 1. UNIT IS BEING INSTALLED OUTSIDE, PROVIDE APPROPRIATE NEMA ENCLOSURE. REMARKS: PUMP SCHEDULE - HVAC MARK LOC AT ROOM TYPE MIN. CAPACITY MIN. SIZE CONN MOTOR (BY M.C.)MANUFACTURER AND MODELGPM FEET HEAD EFF SUCTION DISCH HP RPM SPEED ELECT STARTER P-1 CHILLER PLANT DUAL ARLM VERTICAL INLINE 275 40 4 4 5 1740 - 460/3 VFD ARMSTRONG SERIES 4302 VAV-7.5 Price SDV5 10 875 265 450 1.00 0.25 55.00 95.00 2.10 SCRV 480-3 4.10 7.50 15.00 24 (2) -- 12.00 10.00 VAV-7.4 Price SDV5 8 795 240 240 1.00 0.25 55.00 95.00 3.00 SCRV 480-3 3.80 4.50 15.00 22 (2) -- 12.00 10.00 VAV-7.3 Price SDV5 6 425 130 130 1.00 0.25 55.00 95.00 1.50 SCRV 120-1 10 15.60 20.00 23 (2) -- 12.00 8.00 VAV-7.2 Price SDV5 12 1275 385 450 1.00 0.25 55.00 95.00 5.00 SCRV 120-1 6.67 7.50 15.00 22 (2) -- 12.00 8.00 VAV-7.1 Price SDV5 10 940 280 300 1.00 0.25 55.00 95.00 3.50 SCRV 480-3 4.69 5.30 15.00 -- -- 14.00 12.50 VAV-5.12 Price SDV5 8 500 150 410 1.00 0.25 55.00 95.00 5.30 SCRV 480-3 6.37 8.70 15.00 22 (2) -- 12.00 10.00 VAV-5.11 Price SDV5 6 165 65 125 1.00 0.25 55.00 95.00 1.60 SCRV 120-1 13.33 18.20 20.00 -- -- 12.00 8.00 VAV-5.10 Price SDV5 6 150 65 110 1.00 0.25 55.00 95.00 1.40 SCRV 120-1 11.67 15.90 20.00 -- -- 12.00 8.00 VAV-5.9 Price SDV5 6 300 90 90 1.00 0.25 55.00 95.00 1.20 SCRV 120-1 10 13.60 15.00 23 (2) -- 12.00 8.00 VAV-5.8 Price SDV5 6 155 65 65 1.00 0.25 55.00 95.00 0.80 SCRV 120-1 6.67 9.10 15.00 -- -- 12.00 8.00 VAV-5.7 Price SDV5 8 420 125 160 1.00 0.25 55.00 95.00 2.10 SCRV 120-1 17.50 23.80 25.00 -- -- 12.00 10.00 VAV-5.6 Price SDV5 6 200 65 120 1.00 0.25 55.00 95.00 1.60 SCRV 120-1 13.33 18.20 20.00 21 (2) -- 12.00 8.00 VAV-5.5 Price SDV5 6 250 75 75 1.00 0.25 55.00 95.00 0.80 SCRV 120-1 6.67 9.10 15.00 21 (2) -- 12.00 8.00 VAV-5.4 Price SDV5 6 145 65 75 1.00 0.25 55.00 95.00 1.00 SCRV 120-1 8.33 11.30 15.00 -- -- 12.00 8.00 VAV-5.3 Price SDV5 6 150 65 65 1.00 0.25 55.00 95.00 0.80 SCRV 120-1 6.67 9.10 15.00 -- -- 12.00 8.00 VAV-5.2 Price SDV5 6 175 65 65 1.00 0.25 55.00 95.00 0.80 SCRV 120-1 6.67 9.10 15.00 -- -- 12.00 8.00 VAV-5.1 Price SDV5 8 435 130 130 1.00 0.25 55.00 95.00 1.70 SCRV 120-1 14.17 19.30 20.00 20 (2) -- 12.00 10.00 VAV-4.7 Price SDV5 6 320 95 275 1.00 0.25 55.00 95.00 3.60 SCRV 480-3 4.33 5.90 15.00 24 (2) -- 12.00 8.00 VAV-4.6 Price SDV5 6 250 75 140 1.00 0.25 55.00 95.00 1.80 SCRV 120-1 15 20.40 25.00 24 (2) -- 12.00 8.00 VAV-4.5 Price SDV5 8 525 160 320 1.00 0.25 55.00 95.00 4.10 SCRV 480-3 4.93 6.70 15.00 23 (2) -- 12.00 10.00 VAV-4.4 Price SDV5 6 150 65 65 1.00 0.25 55.00 95.00 0.80 SCRV 120-1 6.67 9.10 15.00 -- -- 12.00 8.00 VAV-4.3 Price SDV5 8 500 150 150 1.00 0.25 55.00 95.00 1.90 SCRV 120-1 15.83 21.60 25.00 22 (2) -- 12.00 10.00 VAV-4.2 Price SDV5 6 250 75 100 1.00 0.25 55.00 95.00 1.30 SCRV 120-1 10.83 14.80 15.00 24 (2) -- 12.00 8.00 VAV-4.1 Price SDV5 6 150 65 65 1.00 0.25 55.00 95.00 0.80 SCRV 120-1 6.67 9.10 15.00 -- -- 12.00 8.00 VAV-3.2 Price SDV5 10 1000 300 300 1.00 0.25 55.00 95.00 3.90 SCRV 480-3 4.69 6.40 15.00 21 (2) -- 14.00 12.50 VAV-3.1 Price SDV5 10 800 240 240 1.00 0.25 55.00 95.00 2.90 SCRV 120-1 24.17 32.90 35.00 -- -- 14.00 12.50 VAV-2.3 Price SDV5 8 600 180 320 1.00 0.25 55.00 95.00 4.10 SCRV 480-3 4.93 6.70 15.00 25 (2) -- 12.00 10.00 VAV-2.2 Price SDV5 8 600 180 320 1.00 0.25 55.00 95.00 4.10 SCRV 480-3 4.93 6.70 15.00 25 (2) -- 12.00 10.00 VAV-2.1 Price SDV5 8 555 165 165 1.00 0.25 55.00 95.00 2.10 SCRV 120-1 17.50 23.80 25.00 24 (2) -- 12.00 10.00 VAV-1.7 Price SDV5 6 200 200 200 1.00 0.25 55.00 95.00 2.30 SCRV 120-1 19.17 26.10 30.00 23 (2) -- 12.00 8.00 VAV-1.6 Price SDV5 6 235 70 175 1.00 0.25 55.00 95.00 2.30 SCRV 120-1 19.17 26.10 30.00 23 (2) -- 12.00 8.00 VAV-1.5 Price SDV5 6 250 75 175 1.00 0.25 55.00 95.00 2.30 SCRV 120-1 19.17 26.10 30.00 23 (2) -- 12.00 8.00 VAV-1.4 Price SDV5 6 230 70 70 1.00 0.25 55.00 95.00 0.80 SCRV 120-1 6.67 26.10 30.00 23 (2) -- 12.00 8.00 VAV-1.3 Price SDV5 6 375 115 115 1.00 0.25 55.00 95.00 1.50 SCRV 120-1 12.50 17.00 20.00 27 (2) 21 (3) 12.00 8.00 VAV-1.2 Price SDV5 6 75 65 65 1.00 0.25 55.00 95.00 0.80 SCRV 120-1 6.67 9.10 15.00 -- -- 12.00 8.00 VAV-1.1 Price SDV5 6 375 115 150 1.00 0.25 55.00 95.00 1.90 SCRV 120-1 15.83 21.60 25.00 27 (2) 21 (3) 12.00 8.00 Tag Manufactu... Model Inlet Dia Max Primary (CFM) Min Primary (CFM) Reheat (CFM) Inlet SP (in. w.g.) Downstream SP (in.... EAT (°F) LAT (°F) EC Capacity (kW) Steps Volts Coil Amps MCA MOP Max Dis NC Max Rad NC Dis. W (in) Dis. H (in) TERMINAL UNIT SCHEDULE 1. PROVIDE WITH ROOF CURB. REMARKS: MAKE-UP AIR UNIT SCHEDULE MARK AIR FILTERS MOTOR (BY M.C.)MANUFACTURER AND MARK CFM ESP FILTER SIZE FILTER TYPE H.P. RPM ELECT STARTER MAU-1 6160 0.5 16x20x2 MV EZ KLEEN 7.5 1226 460/3 - CAPTIVEAIRE DTP7/54 NO. DATE DESCRIPTION PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:13 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 MT102HVAC SCHEDULES Atlantic BeachFleet LandingColeman RemodelFloridaJDB AIR HANDLING UNIT SCHEDULE MARK CFM MIN OA (CFM) FAN COOLING COIL HEATING COIL VOLT/PH FILTER MANUFACTURER & MODEL ACCESSORIES & REMARKSESP (IN) @ S.L.HP TOTAL MBH SENS MBH EAT DB/WB LAT DB/WB EWT/LWT (ºF)GPM EAT ºF LAT ºF kW AHU-1 1610 240 1.5 1.5 47 34 78/66 55/55 44/56 7.5 59 65 3 460/3 MERV 13 ENGINEERED AIR LM2/K/C/MV NOTES A,B,C,E AHU-2 1755 765 1.5 2 92 55 84/71 55/55 44/56 15 50 65 8 460/3 MERV 13 ENGINEERED AIR LM3/K/C/MV NOTES A,B,C,E AHU-3 1800 1025 1.5 2.5 97 59 84/71 55/55 44/56 16 49 65 10 460/3 MERV 13 ENGINEERED AIR LM3/K/C/MV NOTES A,B,C,E AHU-4 2145 360 1.5 3 78 55 78/66 54/54 44/56 13 60 65 4 460/3 MERV 13 ENGINEERED AIR LM4/K/C/MV NOTES A,B,C,E AHU-5 3045 750 1.5 5 113 77 80/68 54/54 44/56 22 55 65 11 460/3 MERV 13 ENGINEERED AIR LM4/K/C/MV NOTES A,B,C,F AHU-6 8495 2985 1.5 10 357 257 82/69 55/54 44/56 58 56 75 60 460/3 MERV 13 SEASONS4 AH-80-EC60-CWC NOTES A,B,C,D,G AHU-7 4310 1200 1.5 5 178 120 82/69 55/55 44/56 29 54 65 25 460/3 MERV 13 SEASONS4 AH-60-EC25-CWC NOTES A,B,C,D,F AHU-8 15000 2000 0.75 15 501 394 82/66 56/55 44/56 82 54 75 60 460/3 MERV 13 SEASONS4 AH-150-EC60-CWC NOTES A,B,C,D,H MECHANICAL EQUIPMENT SCHEDULE MARK SERVICE TYPE CAPACITY/FLOW HP VOLT/ PHASE MANUFACTURER & MODEL AS-1 CHILLED WATER AIR/DIRT SEPARATOR 360 - - AMTROL 8-ADS ET-1 CHILLED WATER EXPANSION TANK 53 GALLONS - - AMTROL 200-L NOTES: A. INDOOR AHU'S WITH CHILLED WATER COILS AND ELECTRIC HEAT. PROVIDE SCR CONTROL OF ELECTRIC HEATING COIL. B. PROVIDE CORROSION RESISTANT COILS AND SUPPLY FAN WITH VFD CONTROL. C. UNITS ARE SPECIFICALLY SELECTED AND SIZED TO FIT INTO ASSOCIATED MECHANICAL CLOSETS AND MEZZANINES. D. AIR HANDLING UNIT SUPPLY FAN VFD AND CONTROL SECTION TO BE REMOTELY MOUNTED IN MEZZANINE. E. PROVIDE ATMOS AIR MATTERHORN 1000 BIPOLAR IONIZATION FOR AIR HANDLER. F. PROVIDE ATMOS AIR MATTERHORN 1002 BIPOLAR IONIZATION FOR AIR HANDLER. G. PROVIDE ATMOS AIR 500FC BIPOLAR IONIZATION FOR AIR HANDLER. H. PROVIDE ATMOS AIR 508FC BIPOLAR IONIZATION FOR AIR HANDLER. 1. 2. PROVIDE WITH BERNER AIR SMART CONTROLLER, MAGNETIC REED DOOR SWITCH AND DISCONNECT SWITCH. PROVIDE LOW VOLTAGE CIRCUIT FOR UNIT ACTIVATION (BAS CONNECTION) WHEN AUTOMATIC DOOR OPENS. REMARKS: AIR CURTAIN SCHEDULE MARK NOZZLE WIDTH (IN) MAX FPM AT NOZZLE CFM AT NOZZLE HEATER kW MOTOR HP VOLTAGE AMPS WEIGHT MANUFACTURER & MODEL AC.1 72 5,444 3,014 NO HEAT (2) @ 1/2 208/1 8.6 185 BERNER ARD12-2072A-B-R-WCA-SS 1.... PROVIDE WITH BAROMETRIC DAMPER.... REMARKS: ROOF HOOD SCHEDULE MARK SERVES INTAKE OR RELIEF HOOD SIZE (IN)CAPACITY MAXIMUM VELOCITY (FPM)REMARKSTHROAT SIZE HOOD SIZE HEIGHT CFM MAX P.D. IN H20 IH-1 AHU-7 OA INTAKE INTAKE 24x24 48x36 19 3,620 0.1 905 NOTE 1 IH-2 AHU-6 & 8 OA INTAKE INTAKE 42x48 72x84 23 10,500 0.1 750 NOTE 1 RH-1 AHU-7 RA RELIEF RELIEF 22x24 32x36 19 3,620 0.2 1,000 NOTE 2 RH-2 AHU-6 RELIEF RELIEF 36x36 54x48 19 9,000 0.2 1,000 NOTE 2 1. LOUVER MOUNTED IN EAVE OVERHANG. REMARKS: LOUVER SCHEDULE MARK TYPE MATERIAL APPROX. SIZE DEPTH FINISH USE DESIGN CFM MAX APD MIN. FREE AREA TOP AT AFF REMARKS L-1 INTAKE ALUMINUM 24x24 4" PER ARCH INTAKE 1,085 0.05 1.94 NOTE 1 AHU-3 OA INTAKE L-2 RELIEF ALUMINUM 30x24 4" PER ARCH RELIEF 2,145 0.05 2.47 NOTE 1 AHU-4 RA RELIEF L-3 INTAKE ALUMINUM 30x30 4" PER ARCH INTAKE 2,145 0.05 3.23 NOTE 1 AHU-4 OA INTAKE L-4 INTAKE ALUMINUM 36x36 4" PER ARCH INTAKE 3,005 0.05 4.49 NOTE 1 AHU-5 OA INTAKE L-5 RELIEF ALUMINUM 30x30 4" PER ARCH RELIEF 3,005 0.05 3.23 NOTE 1 AHU-5 RA RELIEF L-6 INTAKE ALUMINUM 18x12 4" PER ARCH INTAKE 220 0.05 0.54 NOTE 1 AHU-1 OA INTAKE L-7 INTAKE ALUMINUM 30x24 4" PER ARCH INTAKE 1,755 0.05 2.47 NOTE 1 AHU-2 OA INTAKE L-8 RELIEF ALUMINUM 24x24 4" PER ARCH RELIEF 1,755 0.05 1.94 NOTE 1 AHU-2 RA RELIEF NO. DATE DESCRIPTION PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT REVISIONS200332-0006 AUG 2021 200801 MT103HVAC SCHEDULES Atlantic BeachFleet LandingColeman RemodelFloridaJDB 0.14 241 0.150 Xs... Vot... % OA... System OA Intake required is Vot.RTU Total 220.10 1610 (Vou)220.1 Vps 240 VAV.1.7 Occupiable storage rooms for dry... 265 0 0.06 5 15.9 1 1.06 0.91 15.9 0.080 200 30 VAV.1.6 Office space 265 1 0.06 5 20.9 1 1.05 0.91 20.9 0.089 235 35 VAV.1.5 Office space 255 1 0.06 5 20.3 1 1.05 0.91 20.3 0.090 225 35 VAV.1.4 Office space 191 1 0.06 5 16.46 1 1.01 0.91 16.46 0.132 125 20 VAV.1.3 Conference/meeting 395 12 0.06 5 83.7 1 0.91 0.91 83.7 0.223 375 55 VAV.1.2 Office space 164 1 0.06 5 14.84 1 0.94 0.91 14.84 0.198 75 10 VAV.1.1 Lobbies 550 3 0.06 5 48 1 1.01 0.91 48 0.128 375 55 Supply... OA... Zone Type of Space Zone Area... Zone Population... cfm/ft2 (Ra) cfm/person (Rp) Vbz (Az*Ra) +... Ez (Table... Evz (1+Xs-Zd) Ev (min Evz) Voz (Vbz/Ez) Zp (Voz/Vpz) Design Airflows CFM's System: AHU-1 ZONE OA... Multi Zone... 0.16 313 0.178 Xs... Vot... % OA... System OA Intake required is Vot.RTU Total 289.20 1755 (Vou)289.2 Vps 765 VAV.2.3 Restaurant dining rooms 470 8 0.18 7.5 144.6 1 0.92 0.92 144.6 0.241 600 105 VAV.2.2 Restaurant dining rooms 470 8 0.18 7.5 144.6 1 0.92 0.92 144.6 0.241 600 105 VAV.2.1 Occupiable storage rooms for dry... 0 0 0.06 5 0 1 1.16 0.92 0 0.000 555 555 Supply... OA... Zone Type of Space Zone Area... Zone Population... cfm/ft2 (Ra) cfm/person (Rp) Vbz (Az*Ra) +... Ez (Table... Evz (1+Xs-Zd) Ev (min Evz) Voz (Vbz/Ez) Zp (Voz/Vpz) Design Airflows CFM's System: AHU-2 ZONE OA... Multi Zone... 0.18 748 0.246 Xs... Vot... % OA... System OA Intake required is Vot.RTU Total 536.48 3045 (Vou)536.48 Vps 750 VAV.5.12 Office space 307 1 0.06 5 23.42 1 1.13 0.72 23.42 0.047 500 125 VAV.5.11 Office space 146 1 0.06 5 13.76 1 1.09 0.72 13.76 0.083 165 40 VAV.5.10 Office space 165 1 0.06 5 14.9 1 1.08 0.72 14.9 0.099 150 35 VAV.5.09 Breakrooms Office 689 11 0.12 5 137.68 1 0.72 0.72 137.68 0.459 300 75 VAV.5.08 Reception areas 236 3 0.06 5 29.16 1 0.99 0.72 29.16 0.188 155 40 VAV.5.07 Lobbies 494 15 0.06 5 104.64 1 0.93 0.72 104.64 0.249 420 105 VAV.5.06 Office space 132 1 0.06 5 12.92 1 1.11 0.72 12.92 0.065 200 50 VAV.5.05 Lobbies 369 6 0.06 5 52.14 1 0.97 0.72 52.14 0.209 250 60 VAV.5.04 Office space 157 1 0.06 5 14.42 1 1.08 0.72 14.42 0.099 145 35 VAV.5.03 Office space 271 2 0.06 5 26.26 1 1.00 0.72 26.26 0.175 150 35 VAV.5.02 Conference/meeting 190 10 0.06 5 61.4 1 0.83 0.72 61.4 0.351 175 45 VAV.5.01 Office space 513 3 0.06 5 45.78 1 1.07 0.72 45.78 0.105 435 105 Supply... OA... Zone Type of Space Zone Area... Zone Population... cfm/ft2 (Ra) cfm/person (Rp) Vbz (Az*Ra) +... Ez (Table... Evz (1+Xs-Zd) Ev (min Evz) Voz (Vbz/Ez) Zp (Voz/Vpz) Design Airflows CFM's System: AHU-5 ZONE OA... Multi Zone... 0.14 362 0.169 Xs... Vot... % OA... System OA Intake required is Vot.RTU Total 302.24 2145 (Vou)302.24 Vps 360 VAV.4.7 Office space 136 1 0.06 5 13.16 1 1.10 0.83 13.16 0.041 320 55 VAV.4.6 Office space 155 1 0.06 5 14.3 1 1.08 0.83 14.3 0.057 250 40 VAV.4.5 Office space 294 3 0.06 5 32.64 1 1.08 0.83 32.64 0.062 525 90 VAV.4.4 Office space 227 3 0.06 5 28.62 1 0.95 0.83 28.62 0.191 150 25 VAV.4.3 Libraries 1026 6 0.12 5 153.12 1 0.83 0.83 153.12 0.306 500 85 VAV.4.2 Office space 370 3 0.06 5 37.2 1 0.99 0.83 37.2 0.149 250 40 VAV.4.1 Office space 220 2 0.06 5 23.2 1 0.99 0.83 23.2 0.155 150 25 Supply (Vpz) OA (Vpz x %OA) Zone Type of Space Zone Area (Az) Zone Population (Pz) cfm/ft2 (Ra) cfm/person (Rp) Vbz (Az*Ra) + (Pz*Rp) Ez (Table 6.2) Evz (1+Xs-Zd) Ev (min Evz) Voz (Vbz/Ez) Zp (Voz/Vpz) Design Airflows CFM's System: AHU-4 ZONE OA... Multi Zone... 0.41 1029 0.571 Xs... Vot... % OA... System OA Intake required is Vot.RTU Total 732.12 1800 (Vou)732.12 Vps 1025 VAV.3.2 Bars, cocktail lounges 645 8 0.18 7.5 176.1 1 1.23 0.71 176.1 0.176 1000 570 VAV.3.1 Bars, cocktail lounges 1839 30 0.18 7.5 556.02 1 0.71 0.71 556.02 0.695 800 455 Supply... OA... Zone Type of Space Zone Area... Zone Population... cfm/ft2 (Ra) cfm/person (Rp) Vbz (Az*Ra) +... Ez (Table... Evz (1+Xs-Zd) Ev (min Evz) Voz (Vbz/Ez) Zp (Voz/Vpz) Design Airflows CFM's System: AHU-3 ZONE OA... Multi Zone... 8495 2985 225 Bev Supplies 216 6 0.06 5 42.96 1 43.0 43.0 160 60 224 Bar/Bev Station 146 3 0.06 5 23.76 1 23.8 23.8 100 35 220 Atrium 1524 0 0.06 5 91.44 1 91.4 91.4 2400 840 223 Exhibition Dining 4392 150 0.18 7.5 1915.56 1 1915.6 1915.6 5400 1890 222 Exhibition Kitchen 525 2 0.12 7.5 78 1 78.0 78.0 260 95 221 Kitchen Support 222 3 0.12 7.5 49.14 1 49.1 49.1 175 65 Supply (Vpz)OAType of Space Zone Area (Az) Zone Population (Pz) cfm/ft2 (Ra) cfm/person (Rp) Vbz (Az*Ra) + (Pz*Rp) Ez (Table 6.2) Voz (Vbz/Ez) Vot (Voz) Design Airflows CFM's System: AHU-6 Single Zone Recirculati... 0.23 1197 0.278 Xs... Vot... % OA... System OA Intake required is Vot.RTU Total 1004.24 4310 (Vou)1004.24 Vps 1200 VAV.7.5 Restaurant dining rooms 750 28 0.18 7.5 345 1 0.84 0.84 345 0.394 875 245 VAV.7.4 Lobbies 525 0 0.06 5 31.5 1 1.19 0.84 31.5 0.040 795 220 VAV.7.3 Lobbies 319 10 0.06 5 69.14 1 1.07 0.84 69.14 0.163 425 120 VAV.7.2 Restaurant dining rooms 770 28 0.18 7.5 348.6 1 0.96 0.84 348.6 0.273 1275 355 VAV.7.1 Restaurant dining rooms 500 16 0.18 7.5 210 1 1.01 0.84 210 0.223 940 260 Supply... OA... Zone Type of Space Zone Area... Zone Population... cfm/ft2 (Ra) cfm/person (Rp) Vbz (Az*Ra) +... Ez (Table... Evz (1+Xs-Zd) Ev (min Evz) Voz (Vbz/Ez) Zp (Voz/Vpz) Design Airflows CFM's System: AHU-7 ZONE OA... Multi Zone... NO. DATE DESCRIPTION INSULATED PLENUMINSULATED FLEXIBLE DUCT RUNOUT MAXIMUM LENGTH = 6'-0" RUNOUT INSULATED PLENUM CROSS NOTCH OPTION ON 48"LONG SLOTS INSTALL 48"LONG DIFFUSERS OVER TEE-BAR GRID TEE-BAR GRID INSTALL 2-WAY BLOW DIFFUSERS OVER TEE-BAR GRID. G.C. SHALL TRIM CEILING TILE AS REQUIRED. LAY-IN CEILING GRID TEE-BAR GRID INSTALL 1-WAY BLOW DIFFUSERS OVER TEE- BAR GRID. G.C. SHALL TRIM CEILING TILE AS REQUIRED. NOTES: DETAILS TYPICAL FOR 1,2,3 AND 4-SLOT DIFFUSERS. GREASE TROUGH FACTORY ROOF CURB AND EXTENSION. CURB SHALL INTEGRATE WITH ROOF SYSTEM. WELDED GREASE EXHAUST DUCT. PROVIDE FIRE RATED INSULATION BY PABCO OR THERMAL CERAMICS. EXTEND ENCLOSURE DOWN TO HOOD CONNECTION. REFER ALSO TO SPECIFICATIONS. NOTES: 1. DETAIL APPLIES FOR EXHAUST FANS EXHAUSTING GREASE LADEN AIR. 2. FABRICATE CURB TO PROVIDE LEVEL FAN INSTALLATION.41" MIN.24" MIN. DIRECTION OF AIRFLOW.RECTANGULAR MAIN OR TRUNK DUCT MANUAL OPPOSED BLADE BALANCING DAMPER WITH LOCKING QUADRANT, ON BRANCH DUCT OR WHERE INDICATED. NO OBD ON MEDIUM PRESSURE DUCTS BEFORE VAVS. TYPICAL. STANDOFF FOR INSULATION THICKNESS. TYPICAL. SUPPLY EXHAUST RETURN L=4" MINIMUM OR 1/4 OF "W" W 45°LROUND MAIN OR TRUNK DUCT "LOW-LOSS" 45°F ENTRY FITTING GASKET HIGH EFFICIENCY TAKEOFF (HETO). SUPPLY EXHAUST RETURN 45° STRAIGHT GALV. INSULATED DUCT MINIMUM DISTANCE OF 3.0 TIMES BOX INLET DUCT DIAMETER AIRFLOW SENSOR HEATING COIL TRANSITION TO LOW VELOCITY DUCTWORK FLEX CONNECTION LOW VELOCITY SUPPLY AIR DUCT SEE FLOOR PLANS FOR SIZE AND ROUTING. TRANSITION AS REQUIRED TO MATCH BOX OUTLET SIZE MIN. 36" CLEAR CONTROL BOX SHEET METAL TRANSITION AS REQUIRED (REFER TO ACTUAL SUBMITTAL) HIGH EFFICIENCY TAKEOFF MEDIUM VELOCITY TRUNK DUCT FLOW FLOW MINIMUM OF 12" STRAIGHT DUCT, SAME AS VAV BOX OUTLET, OR AS REQUIRED BY MFR PRIOR TO TAKEOFFS, ELBOWS, OR FITTINGS. COIL STRAINER WITH BLOWDOWN VALVE, HOSE THREAD AND CAP SUPPLY RETURN COIL ISOLATION VALVE, 2" AND BELOW BALL VALVE, 2-1/2" AND ABOVE BUTTERFLY VALVE, TYP. FLEX CONNECTION CALIBRATED BALANCING VALVE TCC CONTROL VALVE NOTES: 1. COIL PIPING AND CONTROL VALVE TYPE FOR DIVERTING FLOW. 2. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENT CONTAINING FANS OR COMPRESSORS. BRAIDED STAINLESS STEEL ONLY, NO RUBBER. 3. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATER ENTERS MOST DOWNSTREAM COIL, LEAVES MOST UPSTREAM COIL). 4. REFER TO CONTROLS DRAWINGS FOR ADDITIONAL INFORMATION. 5. 2-WAY VALVE NORMALLY OPEN FOR HEATING AND NORMALLY CLOSED FOR COOLING. 6. COILS WITH MORE OR LESS THAN 2 CONNECTIONS SHALL BE INSTALLED IN A SIMILAR ARRANGEMENTS WITH ALL ACCESSORIES SHOWN HERE FOR EACH COIL SECTION. 7. CONFIRM SUPPLY AND RETURN CONNECTION LOCATIONS WITH EQUIPMENT MANUFACTURER'S LITERATURE PRIOR TO INSTALLATION. 8. MEET MANUFACTURER'S REQUIREMENTS FOR ACTUATOR CLEARANCES AND STEM ORIENTATION. 9. COORDINATE PIPING LOCATION WITH EQUIPMENT ACCESS DOORS, ELECTRICAL JUNCTION BOXES AND DRAIN PIPING. MANUAL AIR VENT AT HIGHEST POINT IN PIPING. PRESS.-TEMP TAP THERMOMETER PRESSURE GAUGE DRAIN DOWN WITH HOSE THREAD AND CAP RETURN COIL ISOLATION VALVE, 2" AND BELOW BALL VALVE, 2-1/2" AND ABOVE BUTTERFLY VALVE, TYP. PRESS.-TEMP TAP FLEX CONNECTION CALIBRATED BALANCING VALVE COIL ISOLATION VALVE, 2" AND BELOW BALL VALVE, 2-1/2" AND ABOVE BUTTERFLY VALVE, TYP. TCC CONTROL VALVE STRAINER WITH BLOWDOWN VALVE, HOSE THREAD AND CAP MANUAL AIR VENT AT HIGHEST POINT IN PIPING NOTES: 1. FLEXIBLE PIPE CONNECTOR REQ'D FOR EQUIPMENT CONTAINING FANS OR COMPRESSORS. BRAIDED STAINLESS STEEL ONLY, NO RUBBER. 2. PIPE ALL MULTI-ROW COILS FOR COUNTERFLOW (WATER ENTERS MOST DOWNSTREAM COIL, LEAVES MOST UPSTREAM COIL). 3. REFER TO CONTROLS DRAWINGS FOR ADDITIONAL INFORMATION. 4. 2-WAY VALVE NORMALLY OPEN FOR HEATING AND NORMALLY CLOSED FOR COOLING. 5. COILS WITH MORE OR LESS THAN 2 CONNECTIONS SHALL BE INSTALLED IN A SIMILAR ARRANGEMENTS WITH ALL ACCESSORIES SHOWN HERE FOR EACH COIL SECTION. 6. CONFIRM SUPPLY AND RETURN CONNECTION LOCATIONS WITH EQUIPMENT MANUFACTURER'S LITERATURE PRIOR TO INSTALLATION. 7. MEET MANUFACTURER'S REQUIREMENTS FOR ACTUATOR CLEARANCES AND STEM ORIENTATION. 8. COORDINATE PIPING LOCATION WITH EQUIPMENT ACCESS DOORS, ELECTRICAL JUNCTION BOXES AND DRAIN PIPING. SUPPLY PRESSURE GAUGE THERMOMETER DRAIN DOWN WITH HOSE THREAD AND CAP TOP VIEW NOTE:PUMPS CONTROLLED BY VFD'S SHALL HAVE INVERTER DUTY RATED MOTORS AND 1,600 VOLT INSULATION. REFER TO SPECIFICATIONS FOR ADDITIONAL MOTOR REQUIREMENTS. PUMP 2 ACTUATOR BY THE TCC. CHANGE OVER VALVE WITH PUMP BUILT IN CHECK VALVE. PUMP 1 PIPING SUPPORT. REFER TO SPECIFICATIONS, TYPICAL. LONG-RADIUS ELBOW SUPPORT PUMP PER MANUFACTURER'S RECOMMENDATIONS. COMBINATION FLOW, CHECK, AND SHUT-OFF VALVE (TRIPLE DUTY). THERMOMETER. ORIFICE PLATE FLOW METER. PROVIDE LENGTH OF STRAIGHT PIPE UP AND DOWNSTREAM PER MANUFACTURER. BUTTERFLY VALVE. VERTICAL INLINE PUMP. PETE'S PLUG. PROVIDE EXTENSION WHERE INSULATION OCCURS, TYPICAL. FLOOR. 1/2" MANIFOLD SUPPORTED FROM PIPE OR WALL. TRUMPET VALVE NOT ALLOWED. 1/4" GAUGE COCK, TYPICAL. 1/4" STAINLESS STEEL TUBING, TYPICAL. WELD-O-LET. SUPPORT SUCTION DIFFUSER PER MANUFACTURER'S RECOMMENDATIONS. CAPPED DRAIN BALL VALVE WITH 3/4" MALE HOSE THREAD OUTLET. SUCTION DIFFUSER WITH STRAINER. MAINTAIN PULL CLEARANCE. PROVIDE START-UP STRAINER. 4" THICK CONCRETE HOUSEKEEPING PAD. CONCENTRIC REDUCER PRESSURE GAUGE, TYPICAL._2D MIN._DREFER TO PLANS FOR PIPE SIZES (TYPICALLY 3D IN) (TYPICALLY 5D OUT)MI N 1.5 D SHORT RADIUS RIGID METAL ELBOWS WHERE 1.50 FLEX ELBOW CAN NOT BE MAINTAINED 1 1/2" DUCT WRAP INSULATION MIN. 1.5" STANDOFF BUTTERFLY DAMPER WITH ARM & LOCKING QUADRANT GASKET HIGH EFFICIENCY TAKEOFF (HETO) ROUND BRANCH DUCT, REFER TO PLANS FOR SIZE FLEX DUCT REFER TO SPECIFICATIONS FOR MAX. ALLOWABLE LENGTH (TYPICAL) STRAP HANGER SUPPLY NYLON STRAP FASTENER (TYP) LOW VELOCITY SUPPLY DUCT PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:20 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 MT200HVAC DETAILS Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO SCALE DIFFUSER DETAIL - SLOT - ADJUSTABLE BLADE8 NO SCALE EXHAUST FAN DETAIL - KITCHEN UPBLAST7 NO SCALE DUCT TAKEOFF DETAILS4 NO SCALE TERMINAL UNIT REHEAT DETAIL3 NO SCALE AHU/RTU COIL PIPING - 3-WAY6 NO SCALE AHU/RTU COIL PIPING - 2-WAY2 NO SCALE PUMP PIPING DETAIL - DUAL ARM VERTICAL IN-LINE5 NO SCALE DIFFUSER INSTALLATION DETAIL1 NO. DATE DESCRIPTION 1"x6"x18 GA. GALV. STRAP POP RIVET TO SUPPORT CHANNEL PVC OR CPVC PIPE HANGER ROD TO STRUCTURE ABOVE VEE BOTTOM CLEVIS HANGER 18 GA GALVANIZED PIPE SUPPORT CHANNEL CONTINUOUS BETWEEN HANGERS PIPE ADJUSTABLE SPLIT RING HANGER, ANVIL FIG. 104 ALL THREAD ROD (TYP) 'C' CLAMP WITH LOCK NUT ANVIL FIG. 86 SIDE BEAM BRACKET ANVIL FIG. 202 BOLT WITH LOCK NUT AND WASHER STRUCTURAL SUPPORTS REFER TO SPECIFICATIONS FOR HANGER SPACING. FIELD BUILT CURB BY G.C. FLASH & COUNTERFLASH AS REQ'D. FRESH-AIR INTAKE HOOD MIN 12"BACKDRAFT DAMPER 1" #16F FLATTENED EXPANDED STEEL W/ 78% FREE AREA CURB BY M.C. FLASH & COUNTERFLASH BY G.C. STEEL ANGLE FRAME INSECT SCREEN RELIEF HOOD MIN 8"FRAMING BY G.C. BIRD SCREEN CAULK EXTENDED SILL SHEET METAL SLEEVE LOUVER CAULK FRAMING BY G.C. EXTENDED SILL WALL OPENING AND FLASHING BY WALL PANEL SUPPLIER. DRIP CAP (METAL BUILDING) NOTE: COORDINATE LOUVER COLOR WITH ARCHITECT PER THE MANUFACTURER'S STANDARD COLOR CHART. BIRD SCREEN CONTROL DAMPER 24V SHEETMETAL SLEEVE ELECTRIC OPERATOR LOUVER FROM EQUIPMENT AIR SEPARATOR FILL CONNECTION FROM CITY WATER PRESSURE RELIEF VALVE PIPE TO FLOOR DRAIN TO PUMP(S)PRESSURE GAUGE (TYP) AUTOMATIC AIR VENT (TYP) BALL VALVE (TYP) ASME EXPANSION TANK. REFER TO SCHEDULE FOR TYPE. 4" HIGH HOUSEKEEPING PAD 3/4" DRAIN. DO NOT PIPE DRAIN LINE ON BLADDER TYPE EXPANSION TANKS. FINISHED FLOOR 3/4" DRAIN VALVE W/CAPPED HOSE BIBB SLOPE CONNECT TO SIDE OF RETURN LINE REFER TO PLANS FOR EXACT LOCATION PLUG VALVE BY-PASS LINE REDUCED PRESSURE BACKFLOW PREVENTER (RPZ) REFER TO PLANS FOR PIPE SIZES. STRAINER PRESSURE REDUCING VALVE PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:22 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 MT201HVAC DETAILS Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO SCALE PIPE SUPPORT DETAIL - CHANNEL2 NO SCALE PIPE SUPPORT DETAIL - SWIVEL RING3 0'8'12'4'NO SCALE HOOD DETAIL - INTAKE1 0'8'12'4'NO SCALE HOOD DETAIL - RELIEF4 0'8'12'4'NO SCALE LOUVER DETAIL - STATIONARY5 0'8'12'4'NO SCALE LOUVER/CONTROL DAMPER DETAIL6 0'8'12'4'NO SCALE EXPANSION TANK/AIR SEPARATOR DETAIL - CITY WATER MAKE-UP7 NO. DATE DESCRIPTION AFMS DM 3 3 5 5 5 5 2 1 3 4 2 1 3 OA RELIEF SA RA T.C.C. LOCATE DUCT STATIC PRESSURE SENSOR 2/3 DOWN MAIN DUCT. AIR FLOW MEASURING STATION(S) PROVIDED BY EQUIP. MFG. INSTALLATION NOTES: SMOKE DAMPERS FURNISHED BY OTHERS GS GR MANUAL RESET LIMIT SWITCHES TO DISABLE FANS ON ALARM DO-S/S DI-ALARM DI-STATUS AO-SPEED AI-PRESS AI-PRESS AI-PRESS AI-FLOW DI-LTD AI-PRESS AI-PRESS AI-FLOW DI-HI PRESS MNL RST AO AI-PRESS AO NC NO NC CC C E F M A S AI-TEMP AI-TEMP T AI H AI AI T AI H AI AI-TEMP T AI H AI AI AI HAI RELATIVE HUMIDITY DI DI AI AI AI AI-TEMP T AI H AI DI AO PRE-FILTER CHILLED WATER COOLING COIL FINAL FILTER FAN WALL STAT DI CSR DOSST DIALA AOSPD EMS SN PWR STAT DI CSR DOSST DIALA AOSPD EMS SN ECM MOTOR BY EQUIP. MFG. MOTOR OVERLOAD CENTER BY AHU MANUFACTURER BUILDING AUTOMATION SYSTEM INTERFACE: THE BUILDING AUTOMATION SYSTEM (BAS) SHALL SEND THE CONTROLLER OCCUPIED BYPASS, MORNING WARM-UP / PRE-COOL, OCCUPIED / UNOCCUPIED AND HEAT / COOL MODES. IF A BAS IS NOT PRESENT, OR COMMUNICATION IS LOST WITH THE BAS THE CONTROLLER SHALL OPERATE USING DEFAULT MODES AND SETPOINTS. OCCUPIED MODE: UNITS SHALL OPERATE CONTINUOSLY UNOCCUPIED MODE: UNITS SHALL OPERATE CONTINUOSLY OPTIMAL START: THE BAS SHALL MONITOR THE SCHEDULED OCCUPIED TIME, OCCUPIED SPACE SETPOINTS AND SPACE TEMPERATURE TO CALCULATE WHEN THE OPTIMAL START OCCURS. MORNING WARM-UP MODE: DURING OPTIMAL START, IF THE SPACE TEMPERATURE IS BELOW THE OCCUPIED HEATING SETPOINT A MORNING WARM-UP MODE SHALL BE ACTIVATED. WHEN MORNING WARM-UP IS INITIATED THE UNIT SHALL ENABLE THE HEATING AND SUPPLY FAN. THE OUTSIDE AIR DAMPER SHALL REMAIN CLOSED. WHEN THE SPACE TEMPERATURE REACHES THE OCCUPIED HEATING SETPOINT (ADJ.), THE UNIT SHALL TRANSITION TO THE OCCUPIED MODE. PRE-COOL MODE: DURING OPTIMAL START, IF THE SPACE TEMPERATURE IS ABOVE THE OCCUPIED COOLING SETPOINT, PRE-COOL MODE SHALL BE ACTIVATED. WHEN PRE-COOL IS INITIATED THE UNIT SHALL ENABLE THE FAN AND COOLING OR ECONOMIZER. THE OUTSIDE AIR DAMPER SHALL REMAIN CLOSED, UNLESS ECONOMIZING. WHEN THE SPACE TEMPERATURE REACHES OCCUPIED COOLING SETPOINT (ADJ.), THE UNIT SHALL TRANSITION TO THE OCCUPIED MODE. OPTIMAL STOP: THE BAS SHALL MONITOR THE SCHEDULED UNOCCUPIED TIME, OCCUPIED SETPOINTS AND SPACE TEMPERATURE TO CALCULATE WHEN THE OPTIMAL STOP OCCURS. WHEN THE OPTIMAL STOP MODE IS ACTIVE THE UNIT CONTROLLER SHALL MAINTAIN THE SPACE TEMPERATURE TO THE SPACE TEMPERATURE OFFSET SETPOINT. OCCUPIED BYPASS: THE BAS SHALL MONITOR THE STATUS OF THE “ON ” AND “CANCEL ” BUTTONS OF THE SPACE TEMPERATURE SENSOR. WHEN AN OCCUPIED BYPASS REQUEST IS RECEIVED FROM A SPACE SENSOR, THE UNIT SHALL TRANSITION FROM ITS CURRENT OCCUPANCY MODE TO OCCUPIED BYPASS MODE AND THE UNIT SHALL MAINTAIN THE SPACE TEMPERATURE TO THE OCCUPIED SETPOINTS (ADJ.). COOLING MODE: THE UNIT CONTROLLER SHALL MONITOR SPACE TEMPERATURE AND SPACE TEMPERATURE COOLING SETPOINT TO DETERMINE WHEN TO INITIATE REQUESTS FOR COOLING. WHEN THE SPACE TEMPERATURE RISES ABOVE THE SPACE TEMPERATURE COOLING SETPOINT, THE UNIT CONTROLLER SHALL MODULATE THE ECONOMIZER OR MODULATE THE COOLING COIL VALVE AS REQUIRED TO MAINTAIN THE SPACE TEMPERATURE COOLING SETPOINT. THE SUPPLY FAN SHALL MODULATE ABOVE MINIMUM SPEED TO MEET ZONE REQUIREMENTS. ONCE THE SPACE TEMPERATURE FALLS BELOW THE SETPOINT THE CHILLED WATER VALVE SHALL BE MODULATE DOWN AND THE FAN SHALL MODULATE TO MINIMUM SPEED. HEATING MODE: THE UNIT CONTROLLER SHALL MONITOR SPACE TEMPERATURE AND SPACE TEMPERATURE HEATING SETPOINT TO DETERMINE WHEN TO INITIATE REQUESTS FOR HEAT. WHEN THE SPACE TEMPERATURE DROPS BELOW THE SPACE TEMPERATURE HEATING SETPOINT, THE CONTROLLER SHALL ENABLE THE ELECTRIC HEATING COIL TO SATISFY THE SPACE TEMPERATURE HEATING SETPOINT. THE SUPPLY FAN SPEED SHALL VARY TO MEET ZONE HEATING REQUIREMENTS IN CONJUNCTION WITH THE ELECTRIC HEATING COIL. ONCE THE SPACE TEMPERATURE RISES ABOVE THE SETPOINT, THE HEATING CYCLE SHALL BE DISABLED. ECONOMIZER CONTROL / REFERENCE DRY BULB: THE SUPPLY AIR SENSOR SHALL MEASURE THE DRY BULB TEMPERATURE OF THE AIR LEAVING THE EVAPORATOR COIL WHILE ECONOMIZING. WHEN ECONOMIZING IS ENABLED AND THE UNIT IS OPERATING IN THE COOLING MODE, THE ECONOMIZER DAMPER SHALL MODULATE BETWEEN ITS MINIMUM POSITION AND 100% TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. MINIMUM POSITION SHALL BE CALCULATED BASED ON SUPPLY FAN SPEED. IF THE MIXED AIR TEMPERATURE STARTS TO FALL BELOW 53.0 DEG. F, THE ECONOMIZER STARTS TO CLOSE, AT 50.0 DEG. F, THE DAMPER SHALL BE AT MINIMUM POSITION. COMPRESSORS SHALL BE DELAYED FROM OPERATING UNTIL THE ECONOMIZER HAS OPENED TO 100% FOR 5 MINUTES. REFERENCE DRY BULB: OUTSIDE AIR (OA) TEMPERATURE IS COMPARED WITH A REFERENCE DRY BULB POINT. THE ECONOMIZER IS ENABLED WHEN OA TEMPERATURE IS LESS THAN REFERENCE DRY BULB POINT. THE ECONOMIZER IS DISABLED WHEN OA TEMPERATURE IS GREATER THAN REFERENCE DRY BULB POINT + 5.0 DEG. F. DEHUMIDIFICATION: THE UNIT SHALL BE IN DEHUMIDIFICATION MODE IF THE RETURN AIR HUMIDITY IS ABOVE THE DEHUMIDIFICATION SETPOINT. IN THE DEHUMIDIFICATION MODE, THE SUPPLY AIR FAN SHALL BE ENABLED, THE OUTSIDE AIR DAMPER SHALL BE COMMANDED TO MINIMUM POSITION, AND THE UNIT CONTROLLER SHALL ENERGIZE MECHANICAL COOLING AND THE REHEAT SOLENOID. MULTI CIRCUIT UNITS: DURING DEHUMIDIFICATION MODE THE OUTSIDE AIR TEMPERATURE SHALL BE MONITORED. IF THIS TEMPERATURE RISES ABOVE THE REHEAT CAPACITY LIMIT SETPOINT, OR FALLS BELOW THE REHEAT CAPACITY LIMIT SETPOINT – 3.0 DEG. F, THE UNIT SHALL STAGE DOWN OR STAGE UP THE COMPRESSORS RESPECTIVELY TO MEET FULL OR PART LOAD CAPACITY REQUIREMENTS BASED ON AMBIENT TEMPERATURE. SUPPLY FAN OPERATION: THE SUPPLY FAN SHALL BE ENABLED WHILE IN THE OCCUPIED MODE AND CYCLED ON DURING THE UNOCCUPIED MODE. THE UNIT CONTROLLER SHALL VARY THE SUPPLY FAN SPEED TO OPTIMIZE MINIMUM FAN SPEED IN ALL COOLING AND HEATING MODES. A DIFFERENTIAL PRESSURE SWITCH SHALL MONITOR THE DIFFERENTIAL PRESSURE ACROSS THE FAN. IF THE SWITCH DOES NOT OPEN WITHIN 40 SECONDS AFTER A REQUEST FOR FAN OPERATION A FAN FAILURE ALARM SHALL BE ANNUNCIATED, THE UNIT SHALL STOP, REQUIRING A MANUAL RESET. BUILDING PRESSURE CONTROL: THE BAROMETRIC RELIEF DAMPERS SHALL OPEN WITH INCREASED BUILDING PRESSURE. AS THE BUILDING PRESSURE INCREASES, THE PRESSURE IN THE UNIT RETURN SECTION ALSO INCREASES, OPENING THE DAMPERS AND RELIEVING AIR. SMOKE DETECTOR SHUTDOWN: THE UNIT SHALL SHUT DOWN IN RESPONSE TO A SIGNAL FROM EITHER SMOKE DETECTOR INDICATING THE PRESENCE OF SMOKE. THE SMOKE DETECTORS SHALL BE INTERLOCKED TO THE UNIT THROUGH THE DRY CONTACTS OF THE SMOKE DETECTORS. A MANUAL RESET OF THE SMOKE DETECTORS SHALL BE REQUIRED TO RESTART THE UNIT. FILTER STATUS: A DIFFERENTIAL PRESSURE SWITCH SHALL MONITOR THE DIFFERENTIAL PRESSURE ACROSS THE FILTER WHEN THE FAN IS RUNNING. IF THE SWITCH CLOSES FOR 2 MINUTES AFTER A REQUEST FOR FAN OPERATION A DIRTY FILTER ALARM SHALL BE ANNUNCIATED AT THE BAS. VARIABLE FRQUENCY DRIVE VFD ERUW VARIABLE FRQUENCY DRIVE VFD ERUW RELATIVE HUMIDITY RELATIVE HUMIDITY RELATIVE HUMIDITY RELATIVE HUMIDITY F M A S F M A S T.C.C. VERIFY # MOTORS/AHU & PROVIDE STATUS SWITCHES FOR ALL MOTORS. BAROMETRIC ELECTRIC HEAT COIL CONTROL NOTES: THE SYSTEM CONSISTS OF A PRESSURE INDEPENDENT VARIABLE AIR VOLUME BOX COMPLETE WITH MOTORIZED DAMPER, THREE STAGE ELECTIC HEATING COIL, AND AIR FLOW PRESSURE TRANDUCER. SCHEDULING: THE ROOM TEMPERATURE SETPOINT SHALL BE SCHEDULED THROUGH THE OPERATOR WORKSTATION SUCH THAT HEATING ROOM TEMPERATURE SETPOINT AND COOLING ROOM TEMPERATURE SETPOINT ARE SET UP AND SET BACK RESPECTIVELY DURING UNOCCUPIED MODES. A THERMOSTAT MOUNTED TIMED OVERRIDE BUTTON SHALL ALLOW ROOM OCCUPANTS TO OVERRIDE THE VAV BOX INTO AN OCCUPIED MODE FOR A SET TIME DURATION SHOULD OCCUPANTS DESIRE TO USE THE SPACE DURING UNOCCUPIED TIMES. THE RESPECTIVE AIR HANDLING UNIT SHALL BE OPERATIONAL WHENEVER VAV BOX IS IN OCCUPIED MODE. CONTROL THE AIRFLOW PRESSURE TRANDUCER SHALL INDICATE TO THE UNIT MOUNTED DDC CONTROLLER MEASURED AIRFLOW. THE DDC CONTROLLER SHALL MODULATE THE VAV BOX DAMPER TO MAINTAIN AIRFLOW AT SETPOINT. AIRFLOW SETPOINT SHALL BE RESET BASED ON THE DIFFERENCE BETWEEN SPACE TEMPERATURE AND SPACE SETPOINT. UPON A RISE IN SPACE TEMPERATURE ABOVE SETPOINT AIRFLOW SHALL MODULATE TO THE MAXIMUM SETPOINT. UPON A FALL IN SPACE TEMPERATURE BELOW SPACE TEMPERATURE SETPOINT AIRFLOW SHALL MODULATE TO THE MINIMUM SETPOINT AND SUBSEQUENTLY ELECTRIC HEATING STAGES ONE THROUGH THREE SHALL ENERGIZE ON. A SPACE MOUNTED TEMPERATURE SENSOR SHALL INCORPORATE A WARMER/COOLER ADJUSTMENT ALLOWING ZONE OCCUPANTS TO BIAS THE SPACE TEMPERATURE SETPOINT BY A FIXED AMOUNT IN EITHER DIRECTION. FEATURES SPACE TEMPERATURE SHALL BE TRENDED HOURLY SPACE TEMPERATURE SETPOINT 5 DEGREES OR MORE ABOVE OR BELOW SETPOINT SHALL ALARM AI AI BI AI BO BO BO AIBO SA TE SPACE MOUNTED T-STAT FROM AHU BO PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:24 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 MT300HVAC CONTROLS Atlantic BeachFleet LandingColeman RemodelFloridaJDB 0'8'12'4'NO SCALE AIR HANDLING UNIT CONTROLS1 0'8'12'4'1/8" = 1'-0" VAV REHEAT CONTROLS2 NO. DATE DESCRIPTION ALL NEW HVAC EQUIPMENT CONTROLS SHALL BE ABLE TO CONNECT AND COMMUNICATE WITH EXISTING JCI METASYS BAS SYSTEM. GENERAL CONTROLS NOTE: CONTROLS NOTES: DESCRIPTION - MAKEUP AIR HANDLING UNIT AND EXHAUST FAN COMPLETE WITH FILTER SECTION, VARIABLE VOLUME EXHAUST FAN AND VARIABLE VOLUME SUPPLY FAN. DAMPERS, AND THEIR ACTUATORS SHALL BE FACTORY PROVIDED. VFDS, SENSORS FOR HOOD HEAT AND PARTICULATES AND SPACE THERMOSTAT SHALL BE PROVIDED AND CONTROLLED BY KITCHEN EQUIPMENT HOOD SUPPLIER. REFER TO KITCHEN CONSULTANT SPECIFICATION FOR SCOPE REQUIRED OF TEMPERATURE CONTROLS CONTRACTOR. COORDINATE EQUIPMENT MOTOR HP WITH KITCHEN EQUIPMENT SUPPLIER FOR PROPER VFD SELECTION. SCHEDULING -THIS UNIT IS NOT SCHEDULED AND SHALL BE INTERLOCKED WITH THE KITCHEN HOOD EXHAUST SYSTEM TO PROVIDE CONDITIONED MAKE UP AIR WHENEVER THE KITCHEN HOOD EXHAUST SYSTEM IS OPERATING. OA DAMPERS SHALL OPEN WHEN EXHAUST FAN IS ACTIVATED. OA DAMPERS SHALL BE CLOSED WHEN EXHAUST FAN IS DE-ENERGIZED. EXHAUST FAN SHALL BE ENERGIZED BY HEAT AND/OR OPTIC SENSORS BY KITCHEN EQUIPMENT SUPPLIER. FAN SPEED CONTROL: KITCHEN HOOD CONTROLS SHALL VARY THE EXHAUST AND MAKEUP AIR FAN SPEED BETWEEN 50% AND 100% DEPENDING ON HEAT AND OPTIC SENSOR REQUIREMENTS. FEATURES - 1. GENERATE AN ALARM SHOULD ANY FAN STATUS NOT MATCH FAN COMMAND. 2. IN THE EVENT OF A FIRE AT THE HOOD, THE FIRE SUPPRESSION SHALL ACTIVATE. HOOD EXHAUST/MUA CONTROL CONSOLE. REFER TO KITCHEN CONSULTANT PLANS FOR MORE INFORMATION HEAT OR OPTICS SENSOR.EAVFD EF-S EF-C COOK-I OA VFD OAD-OOA-T FIL-DP SF-S SF-C DA-T APHI-A SD-S DA AFMS PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:25 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 MT301HVAC CONTROLS Atlantic BeachFleet LandingColeman RemodelFloridaJDB 0'8'12'4'NO SCALE KITCHEN MAU-EXHAUST CONTROLS1 NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6 G DEMO (E) MOP SINK AND ALL ASSOCIATED ACCESSORIES. DEMO (E) DRINKING FOUNTAIN AND ALL ASSOCIATED ACCESSORIES. DEMO WASTE, VENT AND DOMESTIC WATER LINES BACK TO RESPECTIVE MAINS AND CAP. FAUCETS AND DOMESTIC WATER LINES IN (E) RESTROOMS ARE TO BE REMOVED AND REPLACED WITH NEW. (E) 1-1/4" CW UP TO KITCHEN TO REMAIN. (E) 2-1/2" WATER ENTRY TO REMAIN. DEMO (E) DRINKING FOUNTAIN AND ALL ASSOCIATED ACCESSORIES. (E) 3/4" CW LINE TO HOSE BIBB. HOSE BIBB TO REMAIN. (E) CW AND HW RISERS TO (E) BATHROOM GROUPS ON 2ND FLOOR TO BE DEMO'D. REFER TO SHEET P201 FOR NEW ROUTING. (E) CW AND HW MAINS ARE BEING REMOVED AND REPLACED. REFER TO SHEET P201. (E) 1-1/4" CW UP TO KITCHEN TO REMAIN. (E) WATER HEATER AND ALL ASSOCIATED APPURTENANCES TO BE REMOVED. (E) HOSE BIBB TO REMAIN. (E) HOSE BIBB TO BE REMOVED. (E) 4" V UP TO KITCHEN TO REMAIN. (E) COMMON VENT TO REMAIN AND BE REUSED. (E) 750 GALLON SOI TO BE REMOVED. (E) CHILLER HEAT RECLAIM TANK AND ALL ASSOCIATED APPURTNENANCES TO BE REMOVED. PLUMBING DEMO NOTES 1. PLANS ARE SCHEMATIC IN NATURE, LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. CONTRACTOR SHALL CLEAN ALL EXISTING PLUMBING FIXTURES TO REMAIN OR BE REUSED IN AREA OF WORK AND PROVIDE A LIST OF ANY DEFICIENCIES TO OWNER'S REPRESENTATIVE. 3. DEMOLISH ALL DUCTWORK, PIPING AND EQUIPMENT SHOWN SHADED IN A DARK LINE WEIGHT.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:30 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 P1011/8" FIRST FLOOR DEMO PLAN - PLUMBING Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6 G DEMO (E) PLUMBING FIXTURES ASSOCIATED WITH BAR. DEMO (E) WASTE, VENT AND WATER LINES BACK TO MAIN AND CAP. DEMO (E) PLUMBING FIXTURES ASSOCIATED WITH (E) KITCHEN. DEMO (E) WASTE, VENT AND WATER LINES BACK TO MAIN AND CAP. FAUCETS AND DOMESTIC WATER LINES IN (E) RESTROOMS ARE TO BE REMOVED AND REPLACED WITH NEW. (E) GAS LINE THAT IS CONNECTED TO (E) OVEN THAT IS BEING REUSED, SHALL BE DISCONNECTED AND ROUTED TO NEW OVEN LOCATION. REFER TO KITCHEN CONSULTANT. (E) WATER HEATERS AND ALL ASSOCIATED APPURTENANCES TO BE REMOVED AND REPLACED. (E) FLOOR DRAIN IN MECH CLOSET TO REMAIN. ( ) E 1-1/4''G PLUMBING DEMO NOTES 1. PLANS ARE SCHEMATIC IN NATURE, LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. CONTRACTOR SHALL CLEAN ALL EXISTING PLUMBING FIXTURES TO REMAIN OR BE REUSED IN AREA OF WORK AND PROVIDE A LIST OF ANY DEFICIENCIES TO OWNER'S REPRESENTATIVE. 3. DEMOLISH ALL DUCTWORK, PIPING AND EQUIPMENT SHOWN SHADED IN A DARK LINE WEIGHT.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:33 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 P1021/8" SECOND FLOOR DEMO PLAN - PLUMBING Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6 G CONFERENCE ROOM 118 OFFICE 116 FOOD SERVICE DIRECTOR 117 CORRIDOR 115 OFFICE 114 JANITOR 112 EXISTING CORRIDOR 111 EXISTING WATER SUPPLY 110 EXT'G MECH 109 EXISTING STORAGE 106 EXISTING ELECT 107 ? ? ELEVATOR EQUIPMENT 104 SOCIAL MAIL 102 WORK ROOM 129 CONFERENCE ROOM 131 EXECUTIVE GATHERING 128 OFFICE 124 OFFICE 125 OFFICE 126 OFFICE 127 OFFICE 133 MECH 132 SALES & FINISHES 135STAIR 1 001 STAIR 2 002 MARKETING 143LIBRARY DIRECTOR 142 MECH 139 MKTG DIR 146 ? ? SPORTS BAR 155 RECEPTION 122 VEST 123 ELEVATOR LOBBY 121 CORRIDOR 101 IT 138 STORAGE 130 DEVELOPMENT DIRECTOR 103 ATRIUM 136 CORRIDOR 137 REAR VEST 134 SALES & MARKETING 140 OFFICE 141 IL SALES 145 AL SALES 147 OFFICE 149 OFFICE 150 SUPPLY 148 EXISTING LIBRARY 151 MSB.1 DF.1 PROVIDE NEW 4" GREASE WASTE LINE FOR ADDED KITCHEN FIXTURES. ROUTE TO (E) GREASE INTERCEPTOR. SK.2 SK.1 NEW 1,500 GALLON GREASE INTERCEPTOR (SCHIER GGI-1500). CONTRACTOR TO FIELD VERIFY EXISTING CONNECTIONS AND MODIFY AS NEEDED TO CONNECT TO NEW INTERCEPTOR. 4"CO FS FS FD FD FS 2"W ( ) E 4"W( ) E 4"W( ) E 4"W ( ) E 6"W ( ) E 6"W ( ) E 4"W ( ) E 4"W ( ) E 4"W 4"W4"W ( ) E 6"W ( ) E 4"W 4"GW 4"GW 4"GW4"GW 4"GW 4"CO ( ) E 4"W ( ) E 4"W (E) WASTE LINES SERVING PLUMBING FIXTURES TO REMAIN. (E)3" W UP TO SECOND FLOOR MEZZANINE TO REMAIN. (E)CO (E)CO (E)CO 2"W 2"W ( ) E 3"W ( ) E 6"W ( ) E 4"GW (E)4" GW SERVING 2ND FLOOR KITCHEN. P300 3 4"W 1 1 1 2 1 1 4"CO 4"CO 4"CO 4"GW 4"GW 4"GW 4"GW 4"GW 1 4 4 4 3 3 1 4"CO 4"CO FS PLUMBING GENERAL NOTES 1. PLANS ARE SCHEMATIC IN NATURE, LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES. 3. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY SHOWN ON THESE PLANS. PROVIDE CLEANOUTS ON WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE AND FOR REASONABLE MAINTENANCE BASED ON ACTUAL FIELD INSTALLATION. 4. PIPING ON EXTERIOR WALLS OR PRE- CAST WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION. 5. TERMINATE PLUMBING VENTS NOT LESS THAN 12”ABOVE ROOF AND A MINIMUM OF 10’-0”FROM MECHANICAL OUTDOOR AIR INTAKES. 6. AVOID ROUTING OVER ELECTRICAL ROOMS AND ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR. 7. ROUTE DOMESTIC HOT WATER RECIRCULATION PIPES DOWN THE WALL TO WITHIN 2’OF ALL PUBLIC LAVATORIES WITH A ½”RUNOUT. IF TWO OR MORE LAVATORIES SHARE A ¾”OR LARGER BRANCH PIPE, THE HOT WATER RECIRCULATION PIPE SHALL CONNECT TO WITHIN 6”OF EACH LAVATORY. 8. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN ACCESSIBLE LOCATIONS, OR WITH ACCESS PANELS IN HARD-LID CEILINGS. 9. ACCESS PANELS SHALL BE 24X24, U.N.O. LOCATIONS SHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECTS DRAWINGS AND WITH EQUIPMENT LOCATIONS. 10. ALL PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE IN THE CEILNG SPACE. UTILIZE JOIST SPACE WHEN POSSIBLE, ESPECIALLY WHERE CROSSING OTHER PIPES, DUCTS AND ELECTRICAL. 11. PROVIDE ACCESSIBLE SHUT-OFF VALVES TO ALL APPLIANCES AND EQUIPMENT. 12. TRAP GUARDS SHALL BE INSTALLED AT ALL FLOOR RECEPTORS THAT DO NOT RECEIVE REGULAR DISCHARGE. INSTALL IN ACCORDANCE WITH FLORIDA PLUMBING CODE. 13. VERIFY AND REFER TO ARCHITECTURAL DIMENSIONAL FLOOR PLAN FOR EXACT LOCATIONS OF ALL FIXTURES AND EQUIPMENT. 1. 4" GW UP TO 1ST FLOOR CEILING SPACE. 2. 2" GW UP TO 1ST FLOOR CEILING SPACE. 3. 2" W UP TO 1ST FLOOR CEILING SPACE. 4. 4" W UP TO 1ST FLOOR CEILING SPACE. PLAN NOTES PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:39 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 P2001/8" FIRST FLOOR PLAN - UNDERGROUND PLUMBING Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION A B C D E F 1 2 3 4 5 6 CONFERENCE ROOM 118 OFFICE 116 FOOD SERVICE DIRECTOR 117 CORRIDOR 115 OFFICE 114 JANITOR 112EXISTING CORRIDOR 111 EXISTING WATER SUPPLY 110 EXT'G MECH 109 EXISTING ELECT 107 ? ?ELEVATOR EQUIPMENT 104 SOCIAL MAIL 102 WORK ROOM 129 CONFERENCE ROOM 131 EXECUTIVE GATHERING 128 OFFICE 124 OFFICE 125 OFFICE 126 OFFICE 127 OFFICE 133 MECH 132 SALES & FINISHES 135STAIR 1 001 STAIR 2 002 MARKETING 143LIBRARY DIRECTOR 142 MECH 139 MKTG DIR 146 ? ? SPORTS BAR 155 RECEPTION 122 VEST 123 ELEVATOR LOBBY 121 CORRIDOR 101 IT 138 STORAGE 130 DEVELOPMENT DIRECTOR 103 ATRIUM 136 CORRIDOR 137 REAR VEST 134 SALES & MARKETING 140 OFFICE 141 IL SALES 145 AL SALES 147 OFFICE 149 OFFICE 150 SUPPLY 148 EXISTING LIBRARY 151 G MSB.1 SK.2 SK.1 MECH 152 DUMBWAITER 156DUMBWAITER MECHANICAL 153 A/C CLOSET 158 NEW WATER SOFTENER, WS.1 P300 1 1-1/2" CW, 1" HW AND 3/4" HWC UP TO SECOND FLOOR BATHROOM GROUP. REFER TO SHEET P300 FOR CONTINUATION. (E) 3/4" CW TO HOSE BIBB IN WALKWAY. RECONNECT TO (E)1-1/4" CW LINE SERVING 2ND FLOOR KITCHEN FIXTURES. 2" CW, 1-1/2" HW AND 3/4" HWC UP TO WATER HEATERS ON 2ND FLOOR. REFER TO SHEET P202. (E) 2" GAS LINE. COORDINATE (E) METER SIZE WITH UTILITY. (E) 2" GAS LINE UP TO 2ND FLOOR. ROUTE NEW 1-1/2" GAS LINE TO KITCHEN EQUIPMENT. 1-1/2" GAS UP TO KITCHEN EQUIPMENT. CONTRACTOR SHALL MAKE CONNECTION TO SYSTEM REGULATOR. EQUIPMENT MANUFACTURER TO MAKE FINAL CONNECTIONS. (E) 2-1/2" COLD WATER MAIN (UNFILTERED). LINE TO BE REROUTED TO NEW WATER SOFTENER. (E) WASTE AND VENT PIPING TO REMAIN AND BE REUSED IN (E) BATHROOMS. ONLY DOMESTIC WATER PIPING IS BEING REDONE. 1-1/4" CW, 1" HW AND 1/2" HWC DOWN TO BELOW GRADE. PROVIDE SHUT OFF VALVES IN WALL AND PROVIDE ACCESS PANEL. REFER TO 3/P300. 1 1 2 2 1 1 2 2 1 4"GW4"GW 4"GW 4"GW 2 1 2 21 2 1 4"GW 1-1/2''G 1-1/2''G (E) 4" GW RISER SERVING 2ND FLOOR KITCHEN. (E) 3" W SERVING 2ND FLOOR MEZZANINE. 3/4"CW 4 5 3 3 5 4"W 6 6 6 7 7 7 7 7 9 8 88 10 11 12 1-1/4''CW 3/4"HWC 3/4"HW 1-1/4''CW 3/4"HWC 1"HW 1-1/2''CW 3/4"HWC 1"HW PROVIDE STUDOR MINI-VENT AT SINK. PROVIDE STUDOR MINI-VENT AT SINK. 1-1/2''CW 1"HW 3/4"HWC 2"CW 1"HW 3/4"HWC 2"CW 1-1/4''HW 3/4"HWC 2"CW 1-1/2''HW 2-1/2''UCW 3/4"HWC 2-1/2''CW 1-1/2''CW 1-1/4''HW 3/4"HWC 3/4"HWC 1"HW 1-1/2''CW 1-1/4''CW 1"HW 3/4"HWC 2"CW 1-1/2''HW 3/4"HWC 2"CW 3/4"HWC 1-1/2''HW 1-1/4''CW 1-1/2''HW 3/4"HWC (E)4" V UP TO 2ND FLOOR. 3 5 7 13 13 13 13 DF.1 1 4"GW TMV-1 UNDER SINK HB-1 TMV-1 UNDER SINK 2-1/2''UCW 7 PLUMBING GENERAL NOTES 1. PLANS ARE SCHEMATIC IN NATURE, LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES. 3. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY SHOWN ON THESE PLANS. PROVIDE CLEANOUTS ON WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE AND FOR REASONABLE MAINTENANCE BASED ON ACTUAL FIELD INSTALLATION. 4. PIPING ON EXTERIOR WALLS OR PRE- CAST WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION. 5. TERMINATE PLUMBING VENTS NOT LESS THAN 12”ABOVE ROOF AND A MINIMUM OF 10’-0”FROM MECHANICAL OUTDOOR AIR INTAKES. 6. AVOID ROUTING OVER ELECTRICAL ROOMS AND ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR. 7. ROUTE DOMESTIC HOT WATER RECIRCULATION PIPES DOWN THE WALL TO WITHIN 2’OF ALL PUBLIC LAVATORIES WITH A ½”RUNOUT. IF TWO OR MORE LAVATORIES SHARE A ¾”OR LARGER BRANCH PIPE, THE HOT WATER RECIRCULATION PIPE SHALL CONNECT TO WITHIN 6”OF EACH LAVATORY. 8. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN ACCESSIBLE LOCATIONS, OR WITH ACCESS PANELS IN HARD-LID CEILINGS. 9. ACCESS PANELS SHALL BE 24X24, U.N.O. LOCATIONS SHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECTS DRAWINGS AND WITH EQUIPMENT LOCATIONS. 10. ALL PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE IN THE CEILNG SPACE. UTILIZE JOIST SPACE WHEN POSSIBLE, ESPECIALLY WHERE CROSSING OTHER PIPES, DUCTS AND ELECTRICAL. 11. PROVIDE ACCESSIBLE SHUT-OFF VALVES TO ALL APPLIANCES AND EQUIPMENT. 12. TRAP GUARDS SHALL BE INSTALLED AT ALL FLOOR RECEPTORS THAT DO NOT RECEIVE REGULAR DISCHARGE. INSTALL IN ACCORDANCE WITH FLORIDA PLUMBING CODE. 13. VERIFY AND REFER TO ARCHITECTURAL DIMENSIONAL FLOOR PLAN FOR EXACT LOCATIONS OF ALL FIXTURES AND EQUIPMENT. 1. 4" GW UP TO FLOOR SINK ON 2ND FLOOR. 2. 2" GW UP TO FLOOR DRAIN ON 2ND FLOOR. 3. 2" W UP TO LAV ON 2ND FLOOR. 4. 2" W UP TO DF ON 2ND FLOOR. 5. 4" W UP TO WATER CLOSET ON 2ND FLOOR. 6. 4" W DOWN TO BELOW GRADE. REFER TO SHEET P200. 7. 4" GW DOWN TO BELOW GRADE. REFER TO SHEET P200. 8. 2" W DOWN TO BELOW GRADE. REFER TO SHEET P200. 9. 2" GW DOWN TO BELOW GRADE. REFER TO SHEET P200. 10. 2" W, 3/4" CW AND 1/2 HW UP TO HAND SINK. ROUTE 3/4" CW LINE UNDER COUNTER TO OVEN AND FILTER SYSTEM. INSTALL THERMOSTATIC MIXING VALVE AT HAND SINK TO TEMPER WATER TO 105º. COORDINATE WITH KITCHEN CONSULTANT. 11. 1/2" CW AND 1/2" HW UP TO PREP SINK. COODINATE WITH KITCHEN CONSULTANT. 12. 1" CW AND 3/4" HW UP TO KITCHEN FIXTURES ON SECOND FLOOR. ROUTE HOT AND COLD WATER LINES TO KITCHEN EQUIPMENT AS NEEDED. REFER TO KITCHEN CONSULTANT DRAWINGS FOR FIXTURE CONNECTIONS. 13. 3/4" CW AND 3/4" HW UP TO KITCHEN FIXTURES ON SECOND FLOOR. ROUTE 1/2" CW AND HW TO PREP SINK AND HAND SINK. INSTALL THERMOSTATIC MIXING VALVE AT HAND SINK. PLAN NOTES PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:47 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 P2011/8" FIRST FLOOR PLAN - PLUMBING Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION K A B C D E F 1 2 3 4 5 6 G STAIR 1 001 STAIR 2 002 MENS ACCESSIBLE 208 RESTROOM 211 COATS 212 BEV STATION 209 EXISTING WOMENS 206 EXISTING MENS 207 ? ? OFFICE 204 EXHIBITION DINING 223 EXHIBITION KITCHEN 222 KITCHEN SUPPORT 221 GALLERY 220 ELEV LOBBY 213 COMMUNITY DINING 210 BEV STATION 218 PRIVATE DINING/WINE ROOM 219 EXT'G ELEC 217 BEV SUPPLIES 225 BAR/BEV STATION 224 EXISTING MECH 226 EXISTING KITCHEN 201 ELEV 1 E001 ELEV 2 E002 ELEV 3 E003 EXISTING WALK-IN 202 PANTRY 203 J.C. 15 (E) KITCHEN NOT IN SCOPE DF.1 WC.1 LAV.1 LAV.1 WC.1 REFER TO KITCHEN CONSULTANT FOR EXACT FIXTURE LOCATIONS AND CONNECTIONS. REFER TO KITCHEN CONSULTANT FOR EXACT FIXTURE LOCATIONS AND CONNECTIONS. REFER TO KITCHEN CONSULTANT FOR EXACT FIXTURE LOCATIONS AND CONNECTIONS. REFER TO KITCHEN CONSULTANT FOR EXACT FIXTURE LOCATIONS AND CONNECTIONS. LAV.1 WC.1 P300 2 1"CW 1/2"HW WH-1 AND WH-2 IN EXISTING MECH ROOM. CONNECT WATER HEATERS TO (E) 1" GAS SUPPLIES FROM DEMO'D WH'S. ( ) E 1-1/4''G (E)2" GAS FROM 1ST FLOOR. 3/4"HWC (E) WASTE AND VENT PIPING TO REMAIN AND BE REUSED IN (E) BATHROOMS. ONLY DOMESTIC WATER PIPING IS BEING REDONE. 2" CW, 1-1/2" HW AND 3/4" HWC LINES DOWN TO 1ST FLOOR. FD FD FSFS FD FS FS FD (E)3" W LINE FROM MEZZANINE FLOOR DRAIN. FD FS FD FS 3/4" CW, HW AND HWC LINES DOWN TO FIRST FLOOR. 2"V ( ) E 3"V 2"V 2"V (E)4" VTR COMBINE VENTS FROM FLOOR SINK AND FLOOR DRAIN AND ROUTE 3" VTR. CONNECT NEW 2" V LINE FROM KITCHEN EQUIPMENT INTO (E)4" VTR. 2"V 2"V 2"V2"V 3" VTR FS C100.1 C105.1 E100E100 S113.1 S302 S110 S300 S100 S303 W100 W105.1 W107 W301 W302 W300 A106 A302 A300 A108 A301 P200 P201P202 P204 A102.2 TMV-1 UNDER SINK TMV-1 UNDER SINK TMV-1 UNDER SINK TMV-1 UNDER SINK TMV-1 UNDER SINK TMV-1 UNDER P201 AND P202 PLUMBING GENERAL NOTES 1. PLANS ARE SCHEMATIC IN NATURE, LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES. 3. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY SHOWN ON THESE PLANS. PROVIDE CLEANOUTS ON WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE AND FOR REASONABLE MAINTENANCE BASED ON ACTUAL FIELD INSTALLATION. 4. PIPING ON EXTERIOR WALLS OR PRE- CAST WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION. 5. TERMINATE PLUMBING VENTS NOT LESS THAN 12”ABOVE ROOF AND A MINIMUM OF 10’-0”FROM MECHANICAL OUTDOOR AIR INTAKES. 6. AVOID ROUTING OVER ELECTRICAL ROOMS AND ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR. 7. ROUTE DOMESTIC HOT WATER RECIRCULATION PIPES DOWN THE WALL TO WITHIN 2’OF ALL PUBLIC LAVATORIES WITH A ½”RUNOUT. IF TWO OR MORE LAVATORIES SHARE A ¾”OR LARGER BRANCH PIPE, THE HOT WATER RECIRCULATION PIPE SHALL CONNECT TO WITHIN 6”OF EACH LAVATORY. 8. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN ACCESSIBLE LOCATIONS, OR WITH ACCESS PANELS IN HARD-LID CEILINGS. 9. ACCESS PANELS SHALL BE 24X24, U.N.O. LOCATIONS SHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECTS DRAWINGS AND WITH EQUIPMENT LOCATIONS. 10. ALL PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE IN THE CEILNG SPACE. UTILIZE JOIST SPACE WHEN POSSIBLE, ESPECIALLY WHERE CROSSING OTHER PIPES, DUCTS AND ELECTRICAL. 11. PROVIDE ACCESSIBLE SHUT-OFF VALVES TO ALL APPLIANCES AND EQUIPMENT. 12. TRAP GUARDS SHALL BE INSTALLED AT ALL FLOOR RECEPTORS THAT DO NOT RECEIVE REGULAR DISCHARGE. INSTALL IN ACCORDANCE WITH FLORIDA PLUMBING CODE. 13. VERIFY AND REFER TO ARCHITECTURAL DIMENSIONAL FLOOR PLAN FOR EXACT LOCATIONS OF ALL FIXTURES AND EQUIPMENT.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:43:53 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 P2021/8" SECOND FLOOR PLAN - PLUMBING Atlantic BeachFleet LandingColeman RemodelFloridaJDB NO. DATE DESCRIPTION B C 1 1"CW 3/4"CW 3/4"HW 1/2"HWC 1/2"HWC 1/2"HW 1"CW 3/4"HW 3/4"CW 1/2"HWC 1-1/2''CW 1-1/4''CW1-1/4''CW 3/4"CW 3/4"HW 1/2"HWC (E) LAV FAUCETS ARE TO BE REMOVED AND REPLACED WITH KOHLER K-104B87-SANA. (E) LAV FAUCET TO BE REMOVED AND REPLACED WITH KOHLER K-104B87-SANA. (E) LAV FAUCET TO BE REMOVED AND REPLACED WITH KOHLER K-104B87-SANA. (E) LAV FAUCETS ARE TO BE REMOVED AND REPLACED WITH KOHLER K-104B87-SANA. TMV-1 UNDER SINK TMV-1 UNDER SINK TMV-1 UNDER SINK TMV-1 UNDER SINK F 3 4 DF.1 1"CW 3/4"CW WC.1 LAV.1 WC.1 LAV.1 (E) LAV FAUCETS ARE TO BE REMOVED AND REPLACED WITH KOHLER K-104B87- SANA. TMV-1 UNDER SINK TMV-1 UNDER SINKS, TYP. (4) TMV-1 UNDER SINK B C 3 4 1-1/4"CW, 1" HW AND 1/2" HWC UP TO FIRST FLOOR CEILING SPACE. REFER TO SHEET P201. ALL UNDERGROUND PLUMBING TO BE SLEEVED. ROUTE 3/4" PIPE UP ABOVE SLAB TO COUNTER. ROUTE 3/4" CW LINE TO WATER FILTER SYSTEM, B141.1. BRANCH 3/8" LINE AND ROUTE WITHIN COUNTER TO ESPRESSO MACHINE, B141. REFER TO KITCHEN CONSULTANT. ROUTE 1" CW LINE UP ABOVE SLAB AND BRANCH INTO 3/4" LINES TO SERVE WATER FILTER SYSTEMS, B122.1 AND B129.1. REFER TO KITCHEN CONSULTANT. PROVIDE THERMOSTATIC MIXING VALVE AT HAND SINK, B133, TO TEMPER WATER TO 110º. ROUTE 1-1/4" CW AND HW UP TO VIEGA MANABLOC DISTRIBUTION MANIFOLD UNDER 4-COMP SINK (B134). CONTRACTOR TO ROUTE HOT AND COLD WATER LINES TO KITCHEN EQUIPMENT FROM MANIFOLD WITHIN THE BAR SYSTEM. REFER TO KITCHEN CONSULTANT FOR FIXTURES AND CONNECTION SCHEDULE. 1-1/4''CW 1-1/4''HW 3/4"HWC 1"CW B134 B122 B133 B129 B129 B125 B124 B122.1 B124B125B129.1 PLUMBING GENERAL NOTES 1. PLANS ARE SCHEMATIC IN NATURE, LAYOUT IS BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES FROM THE DRAWINGS AND NOTES TO THE OWNER'S REPRESENTATIVE IMMEDIATELY. MINOR CHANGES IN THE SCOPE OF THE DEMOLITION WORK SHALL NOT JUSTIFY AN ADDITIONAL COST. 2. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES. 3. PIPING ON EXTERIOR WALLS OR PRE- CAST WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION. 4. AVOID ROUTING OVER ELECTRICAL ROOMS AND ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR. 5. ROUTE DOMESTIC HOT WATER RECIRCULATION PIPES DOWN THE WALL TO WITHIN 2’OF ALL PUBLIC LAVATORIES WITH A ½”RUNOUT. IF TWO OR MORE LAVATORIES SHARE A ¾”OR LARGER BRANCH PIPE, THE HOT WATER RECIRCULATION PIPE SHALL CONNECT TO WITHIN 6”OF EACH LAVATORY. 6. ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN ACCESSIBLE LOCATIONS, OR WITH ACCESS PANELS IN HARD-LID CEILINGS. 7. ACCESS PANELS SHALL BE 24X24, U.N.O. LOCATIONS SHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECTS DRAWINGS AND WITH EQUIPMENT LOCATIONS. 8. ALL PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE IN THE CEILNG SPACE. UTILIZE JOIST SPACE WHEN POSSIBLE, ESPECIALLY WHERE CROSSING OTHER PIPES, DUCTS AND ELECTRICAL. 9. PROVIDE ACCESSIBLE SHUT-OFF VALVES TO ALL APPLIANCES AND EQUIPMENT. 10. VERIFY AND REFER TO ARCHITECTURAL DIMENSIONAL FLOOR PLAN FOR EXACT LOCATIONS OF ALL FIXTURES AND EQUIPMENT.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:44:00 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 P3001/4" ENALRGED PLANS - PLUMBING Atlantic BeachFleet LandingColeman RemodelFloridaJDB 0'8'12'4'1/4" = 1'-0" PLUMBING PLAN - 1ST FLOOR ENLARGED BATHROOM1 0'8'12'4'1/4" = 1'-0" PLUMBING PLAN - 2ND FLOOR ENLARGED BATHROOM2 0'8'12'4'1/4" = 1'-0" PLUMBING PLAN - ENLARGED BAR3 NO. DATE DESCRIPTION SK.2 SK.1 1"CW (E) URINALS 3/4"CW (3)(E) WATER CLOSETS 1-1/2''CW 1-1/4''HW 3/4"HWC 1"CW WC.1LAV.1 1-1/4''CW 1"CW DF.1 (E) LAVS 1"CW 1"CW WC.1 LAV.1 1"CW WC.1 LAV.1 1-1/2''CW 1"HW 3/4"HWC 1-1/4''CW 1"HW 3/4"HWC HOSE BIBB TO KITCHEN EQUIPMENT. REFER TO KITCHEN CONSULTANT DRAWINGS. HOSE BIBB 3/4"CW 1-1/4''CW 3/4"HW 3/4"HWC 3/4"CW 3/4"HW 2"CW 1"HW 3/4"HWC RISER TO SECOND FLOOR BATHROOM GROUPS. 3/4"CW TO (E) HOSE BIBB (E)1/1-4" CW LINE TO (E) KITCHEN. (E)2-1/2" UNFILTERED COLD WATER LINE FROM METER. WH-1 AND WH-2 2"CW 1-1/2''HW 3/4"HWC UP TO WATER HEATERS ON SECOND FLOOR. TO KITCHEN EQUIPMENT. REFER TO KITCHEN CONSULTANT DRAWINGS. 2"CW 1-1/2''HW 3/4"HWC 2-1/2''UCW 1/2"HW 3/4"CW 3/4"CW 3/4"HW 1/2"HW 1/2"CW 3/4"CW 3/4"HW 1-1/2''CW 1-1/4''HW 3/4"HWC TO NEW WATER SOFTENER. 2-1/2''CW DF.1 1"CW 2-1/2''CW 2"CW 1-1/2''HW 3/4"HWC (E) LAV'S (E) LAV (E) WC (E) UR'S (E) LAV (E) SHWR (E) WC'S (E) LAV'S 1"CW3/4"CW 3/4"HW 1"CW 1/2"HWC 1/2"HWC 1/2"HW 1"CW 3/4"CW 3/4"HW 1/2"HWC 1/2"CW 1/2"HW 1/2"HWC TO KITCHEN EQUIPMENT. REFER TO KITCHEN CONSULTANT DRAWINGS. 1-1/2''CW 1"HW 3/4"HWC 3/4"HWC 1"HW 1-1/4''CW TO KITCHEN EQUIPMENT. REFER TO KITCHEN CONSULTANT DRAWINGS. 3/4"HWC 1-1/4''HW 1-1/4''CW 3/4"HWC 3/4"HW 3/4"CW 1"HW PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:44:07 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 P400PLUMBING RISER DIAGRAMS Atlantic BeachFleet LandingColeman RemodelFloridaJDB 0'8'12'4' WATER RISER1 NO. DATE DESCRIPTION FD FS FS FD FS FD FS FS FD FS FD FS FD FS FD FS 4"CO 4"CO 4"CO 4"CO 4"CO 4"CO 4"CO FD FS 4"CO 2"GW 4"GW 4"GW 4"GW 4"GW 4"GW4"GW 4"GW 4"GW 4"GW 4"GW 4"GW 4"GW 4"GW 4"GW 4"GW 4"GW 4"GW 4"GW ( ) E 4"GW (E) 4" GREASE WASTE SERVING (E) KITCHEN. TO (E) GREASE INTERCEPTOR ( ) E 4"W ( ) E 4"W (E)4"CO ( ) E 6"W ( ) E 6"W ( ) E 6"W ( ) E 4"W ( ) E 4"W ( ) E 4"W ( ) E 4"W CONTRACTOR SHALL FIELD VERIFY (E) WASTE MAINS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL FIELD VERIFY (E) WASTE MAINS PRIOR TO CONSTRUCTION. ( ) E 4"W ( ) E 4"W ( ) E 4"W (E) WASTE FROM GREASE INTERCEPTOR. 2"W 2"W ( ) E 3"W 4"W 4"W 4"W 4"W ( ) E 4"V ( ) E 4"V ( ) E 4"V 2"V ( ) E 4"V PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:44:14 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 P401PLUMBING RISER DIAGRAMS Atlantic BeachFleet LandingColeman RemodelFloridaJDB 0'8'12'4' GREASE WASTE1 0'8'12'4' WASTE2 NO. DATE DESCRIPTION DS GDS COLD WATER SUPPLY HWC FROM FIXTURES DIAPHRAGM TYPE EXPANSION TANK. AMTROL OR EQUIVALENT RELIEF VALVE, PIPE INDIRECT TO DRAIN PAN OR FLOOR DRAIN, TYP. GAS SUPPLY. DOMESTIC HW RECIRC. PUMP GAS WATER HEATER 140º HOT WATER TO SYSTEM GAS COCK (TYP) GAS WATER HEATER CONCRETE HOUSEKEEPING PAD, TYP. THERMOMETER, TYP. BALL VALVE, TYP. UNION, TYP. CHECK VALVE, TYP. CALIBRATED BALANCE VALVE AQUASTAT TO CYCLE PUMP A NOTES: 1. REFER TO PLANS FOR PIPE SIZES. 2. INDICATE FLOW DIRECTION AND LABEL ALL PIPING AND EQUIPMENT. 3. REFER TO PLANS FOR FLUE AND COMBUSTION AIR PIPE ROUTING. CONTRACTOR SHALL VERIFY VENTING REQUIREMENTS WITH UNIT MANUFACTURER. 4. 120V ELECTRICAL CONNECTION REQUIRED FOR GAS WATER HEATERS. 5. PROVIDE COMMON MANIFOLD. ALL PIPING, VALVING, AND FITTINGS SHALL BE EQUAL AND SYMMETRICAL FOR EQUAL DEMAND AT EACH HEATER. 6. WATER HEATERS SHALL PROVIDE 140º WATER. POINT OF USE THERMOSTATIC MIXING VALVES WILL BE INSTALLED WHERE NECESSARY. REFER TO PLANS. CLEANOUT, TYP. TWO-WAY CLEANOUT FITTING CLEANOUT AT GRADE, TYP. INLET REINFORCED CONCRETE TANK 24"∅RETAINING WALL (TYPICAL) OUTLET MUST BE AT LEAST 2" LOWER THAN INLET USE 2ea DEETER 1261 FOR HEAVY DUTY OR EQUAL PAVEMENT SECTION VIEW PLAN VIEW NOTES: 1. CONSTRUCTION OF TANK AND INSTALLATION SHALL COMPLY WITH ALL FEDERAL, STATE AND LOCAL CODE REQUIREMENTS. 2. FIELD VERIFY ALL REQUIRED WASTE FLOW LINES FOR CONNECTION TO TANK PRIOR TO TANK CONSTRUCTION. 3. CONSTRUCT TANK AS REQUIRED TO PROVIDE SPECIFIED RETAINAGE CAPACITY. 4. BOX DESIGN LOAD: H-20 TRAFFIC WITH 1' TO 6' SOIL COVER. 5. ADDITIONAL PIPING MAY BE REQUIRED. COORDINATE EXACT EQUIPMENT AND PIPING REQUIREMENTS WITH EQUIPMENT SUPPLIER. NOTE: REFER TO PLANS FOR PIPE SIZES FLOOR/HUB DRAIN FLOOR CLOSED DIAPHRAGM WASTE PIPE OPEN DIAPHRAGM WASTE PIPE NOTES: TRAP GUARD DIAPHRAGM AS MANUFACTURED BY PROSET SYSTEMS, INC. REFER TO SPECIFICATION. WHERE ALLOWED BY LOCAL CODE, TRAP GUARD MAY BE USED IN LIEU OF TRAP PRIMER. TYPICAL ALL FLOOR DRAINS. BRINE MAKER PIPE TO FLOOR DRAIN UNIT CONTROL CENTER PRESSURE GAGE WATER SOFTENER TANK WATER METER UNION (TYP) BALL VALVE (TYP) BY-PASS VALVE SOFTENED WATERHARD CW THIS DETAIL IS FOR REFERENCE ONLY. COORDINATE EXACT PIPING AND INSTALLATION REQUIREMENTS WITH MANUFACTURER.PROFESSIONAL ENGINEERING CONSULTANTS, P.A.316-262-2691 www.pec1.com303 SOUTH TOPEKA, WICHITA, KS 67202PEC PROJECT NUMBER:DATE THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL NOT BE COPIED IN ANY FORM OR MANNER WITHOUT WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR SHEET NO. PROJECT SHEET PRINTED ON:FILE PATH:REVISIONS200332-0008/5/2021 7:44:16 AMBIM 360://200801-Fleet Coleman Remodel/200332-000-MASTER MECH-R20.rvt6 AUG 2021 200801 PT100PLUMBING SCHEDULES AND DETAILS Atlantic BeachFleet LandingColeman RemodelFloridaJDB FIXTURE CONNECTION SCHEDULE MARK FIXTURE WATER WASTE VENT REMARKSCOLD HOT RUNOUT CONN.RUNOUT CONN. RUNOUT CONN. LAV LAVATORY 1/2" 3/8" 1/2" 3/8" 2" 1-1/4" 1-1/2" MSB MOP BASIN 3/4" 1/2" 3/4" 1/2" 3" 3" 2" SK KITCHEN SINK 1/2" 3/8" 1/2" 3/8" 2" 1-1/4" 1-1/2" WC WATER CLOSET (TANK) 3/4" 1/2" -- -- 4" 3" 2" PLUMBING FIXTURE SCHEDULE MARK FIXTURE TYPE ADA FINISH MANUFACTURER & MODEL FAUCET TRIM MANF & MODEL HARDWARE, PLUG OR BATTERY POWERED ACCESSORIES REMARKS DF.1 BI-LEVEL ADA WATER COOLER BOTTLE FILLER YES LIGHT GRAY GRANITE ELKAY EZSTL8WSVRLK - PLUG - 120/1 (6 FLA) FD FLOOR DRAIN - NICKEL BRONZE ZURN Z415B - - SELF CLOSING TRAP SEAL BY PROSEAL OR SURE SEAL 3" OUTLET U.N.O. FS FLOOR SINK - STAINLESS STEEL ZURN Z1750 - - SELF CLOSING TRAP SEAL BY PROSEAL OR SURE SEAL 3" OUTLET U.N.O. HB-1 WALL HYDRANT - CHROME WOODFORD B65 - - - - LAV.1 UNDERMOUNT LAVATORY-ROUND YES WHITE VITREOUS CHINA KOHLER K-2210 KOHLER K-104B87-SANA BATTERY - 0.5 GPM MSB.1 MOP SINK - MOLDED STONE FIAT TSB-3010 CHICAGO FACUET 897-CCP - - 24x24x12 SK.1 BAR SINK YES STAINLESS STEEL ELKAY BCR15 ELKAY LKAV3021 - - - SK.2 DOUBLE BOWL KITCHEN SINK YES STAINLESS STEEL ELKAY GECR3321 ELKAY LKAV3021 - - 1.8 GPM TMV-1 THERMOSTATIC MIXING VALVE - - WATTS LFE480 - - ASSE 1070 SET AT 105 DEG. F WC.1 FLUSH TANK WATER CLOSET YES WHITE VITREOUS CHINA AMERICAN STANDARD 2467.016 - - ADA TOILET SEAT WATER CLOSET TO MATCH EXISTING. WS.1 WATER SOFTENER - - KINETICO HYDRUS HS230s - - - NOTE A 1. 2. WHERE REQUIRED BY LOCAL STATE AND FEDERAL AUTHORITIES HAVING JURISDICTION, CONTRACTOR SHALL PROVIDE ALL REQUIREMENTS FOR WATER HEATERS CONSIDERED BOILERS INCLUDING EMERGENCY SHUTOFF SWITCH. PROVIDE WITH COMMON CONCENTRIC VENT KIT AND SINGLE AMTROL ST-12 EXPANSION TANK REMARKS: WATER HEATER SCHEDULE MARK LOC. AT ROOM TYPE MIN. CAPACITY GAS MANUFACTURER AND MODEL RECIRC PUMP REFGAL STOR GPH RECOVERY AT 100° RISE INPUT MBH VENT DIA. VENT MOTOR H.P. ELECT WH-1 E MECH 226 STORAGE 119 499.9 AO SMITH BTH-500 DHWP-1 WH-2 E MECH 226 STORAGE 119 399.9 AO SMITH BTH-400 DHWP-1 NO SCALE WATER HEATER DETAIL - GAS - DUPLEX, RECIRC.1 1. REMARKS: PUMP SCHEDULE MARK LOC AT ROOM TYPE MIN CAPACITY MIN SIZE CONN MOTOR (BY M.C.)MANUFACTURER AND MODELGPM FEET HEAD EFF SUCTION DISCH HP RPM SPEED ELECT STARTER DHWP-1 E MECH 226 INLINE 12 20 - 1" 1" 1/8 - - 120/1 - B&G ECOCIRC 0'8'12'4'NO SCALE GREASE INTERCEPTOR DETAIL2 0'8'12'4'NO SCALE FLOOR DRAIN TRAP GUARD DETAIL3 0'8'12'4'NO SCALE WATER SOFTENER DETAIL4 NOTES: A. PROVIDE WITH (2) BRINE TANKS AND HYDRUS SMART CONTROLLER, BASE. COORDINATE WITH CGC WATER TREATMENT. NO. DATE DESCRIPTION