Loading...
176 Ocean Blvd 07-00000058 Install 14 Fixtures J� S r } '�•� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5826 ��US31�r Application Number . . . . . 07-00000058 Date 2/05/07 Property Address . . . . . . 176 OCEAN BLVD Application type description PLUMBING ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---- --------------------------------------------- --------------------------- Application desc install 14 fixtures ---------------------------------------------------------------------------- Owner Contractor ------------------------ ----------------------- - THOMASSY DAN BRYANT PLUMBING 176 OCEAN BLVD. P .O. BOX 331275 ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 242-9256 ------------------------ --------------------- ------ -------------- - - --------- Permit . . . . . . PLUMBING PERMIT Additional desc . . Permit Fee . . . . 133 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 8/04/07 ----------------------------------------------------------------- ----------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- --------- - Permit Fee Total 133 . 00 133 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 133 . 00 133 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. to tom' 3 CITY OF ATLANTIC BEACH PLUMBING PERMIT APPLICATION Date: ' S - v &VdProperty Address: Owner: CIR 15 I¢ Telephone#: Contractor*al &d /•U Telephone#:1� Contractor Address: e Fax Contractor Signature: rl�) /-�' -C� In consideration of permit given for doing the work as described in th a ve statement,we hereby agree to perform said work in accordance with the attached plans and specifications which are a parnereof and in accordance with the City of Atlantic Beach ordinance and standards of good practice listed therein. Installation of plumbing and fixtures must be in accordance with the most recent edition of the Southern Standard Plumbing Code. Plumbing Type: If other construction is being done on this building or site, ❑ New list the building permit number: Re-Pipe Number of Fixtures: 2- Bath Tubs / Showers Closets Shower Pans Dishwashers Sinks Disposals Urinals Floor Drains _ Washing Machine 3 Lavatory Water Sewer Water Heaters Sprinkler System k&MeAaXh01 she see For Backflow and Irrigation procedures Fees Permit Issuing Fee: $35.00 Total Fixtures: _ X$7.00 + $35.00 = 800 Seminole Road • Atlantic Beach, Florida 32233-5445 Phone: (904) 247-5800 • Fax: (904) 247-5845• http://www.ci.atlantic-beach.fl.us Revised 9/06 CITY OF ATLANTIC BEACH CROSS CONNECTION CONTROL BACKFLOW PREVENTER INSTALLATION REQUIREMENTS INSTALLATION: General installation instructions. 1. All devices larger than 2 inch must be installed on hard metal pipe. The metal piping must include all components up to and including the first upstream and down stream underground elbow joints. 2. Assemblies 2 inches and smaller may be installed on PVC pipe. Schedule 80 pipe must be used near trafficked areas. Support brackets and guard posts are recommended. 3. Device assemblies are to be installed a minimum of 12 inches above flood grade. Measurement is to be made from the lowest point of the device. The maximum height of a horizontally installed assembly is not to exceed 60 inches. No vaulted installations are allowed. 4. Vertical installation of DCAs is permitted on fire risers only and only if approved by USCFCCCHR. 5. All Devices are to be installed in a manner to facilitate testing. All valves must be fully operational. All test cocks must be easily accessible. 6. Freeze protection is required for Fire Suppression System Backflow Preventers and is recommended for all other Backflow Preventer installations. Such protection may not prevent the unit from operating or being tested. All Backflow Preventers must be inspected by a COJB representative prior to application of freeze protection. 7. Thermal expansion must be addressed in situations were a device application may restrict such expansion. 8. AVBs and PVBs must be installed a minimum of 12 inches above the highest outlet served.No valve may exist downstream from these devices. 9. CALL MALCOLM CLEMONS AT 247 5839